MIBs Depot

HUAWEI-REDUNDANCY-POWER-MIB

Registered at
1.3.6.1.4.1.2011.2.33.4
1.3.6.1.4.1.2011.2.33.5
Last updated
2001-12-20 00:00
Organization
Huawei Technologies Co., Ltd
Namespace
huawei
Source file
HUAWEI-REDUNDANCY-POWER-MIB
Digest
sha256:31f2e5f00b975aa26610316faafee41e0ed5725bcc5a1d8217d3d65e5631bf9d

Contact

VRP Team Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China http://www.huawei.com Zip:100085

Imports

FromSymbols
HUAWEI-3COM-OID-MIBmlsr
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HUAWEI-3COM-OID-MIB
HUAWEI-REDUNDANCY-POWER-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
redundancyPowerTable
OBJECT-TYPE
The table describles the attributes of every power unit.
1.3.6.1.4.1.2011.2.33.4.1not-accessiblecurrent
redundancyPowerEntry
OBJECT-TYPE
Each entry contains the attributes associated with a single power unit entity.
1.3.6.1.4.1.2011.2.33.4.1.1not-accessiblecurrent
redundancyPowerID
OBJECT-TYPE
The identify of power uinit. This is also the index of this table.
1.3.6.1.4.1.2011.2.33.4.1.1.1INTEGERread-onlycurrent
redundancyPowerStatus
OBJECT-TYPE
The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail'
1.3.6.1.4.1.2011.2.33.4.1.1.2INTEGER {space(1), normal(2), fail(3)}read-onlycurrent
redundancyPowerPreviousStatus
OBJECT-TYPE
The last status of every redundancy power unit
1.3.6.1.4.1.2011.2.33.4.1.1.3INTEGER {space(1), normal(2), fail(3)}read-onlycurrent
powerTraps
OBJECT-IDENTITY
1.3.6.1.4.1.2011.2.33.4.2
redundancyFan
OBJECT-IDENTITY
1.3.6.1.4.1.2011.2.33.5
redundancyFanTable
OBJECT-TYPE
The table describles the attributes of every power unit.
1.3.6.1.4.1.2011.2.33.5.1not-accessiblecurrent
redundancyFanEntry
OBJECT-TYPE
Each entry contains the attributes associated with a single power unit entity.
1.3.6.1.4.1.2011.2.33.5.1.1not-accessiblecurrent
redundancyFanID
OBJECT-TYPE
The identify of power uinit. This is also the index of this table.
1.3.6.1.4.1.2011.2.33.5.1.1.1INTEGERread-onlycurrent
redundancyFanStatus
OBJECT-TYPE
The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail'
1.3.6.1.4.1.2011.2.33.5.1.1.2INTEGER {normal(1), fail(2)}read-onlycurrent
fanTraps
OBJECT-IDENTITY
1.3.6.1.4.1.2011.2.33.5.2

Notifications

NameOIDStatus
powerStatusChangedTrap
NOTIFICATION-TYPE
This trap is generated when the satus of a power unit is changed.
1.3.6.1.4.1.2011.2.33.4.2.1current
fanStatusChangedTrap
NOTIFICATION-TYPE
This trap is generated when the satus of a power unit is changed.
1.3.6.1.4.1.2011.2.33.5.2.1current