HUAWEI-REDUNDANCY-POWER-MIB
- Registered at
- 1.3.6.1.4.1.2011.2.33.41.3.6.1.4.1.2011.2.33.5
- Last updated
- 2001-12-20 00:00
- Organization
- Huawei Technologies Co., Ltd
- Namespace
- huawei
- Source file
HUAWEI-REDUNDANCY-POWER-MIB- Digest
sha256:31f2e5f00b975aa26610316faafee41e0ed5725bcc5a1d8217d3d65e5631bf9d
Contact
VRP Team Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China http://www.huawei.com Zip:100085
Imports
| From | Symbols |
|---|---|
| HUAWEI-3COM-OID-MIB | mlsr |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HUAWEI-3COM-OID-MIB HUAWEI-REDUNDANCY-POWER-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| redundancyPowerTable OBJECT-TYPE The table describles the attributes of every power unit. | 1.3.6.1.4.1.2011.2.33.4.1 | not-accessible | current | |
| redundancyPowerEntry OBJECT-TYPE Each entry contains the attributes associated with a single power unit entity. | 1.3.6.1.4.1.2011.2.33.4.1.1 | not-accessible | current | |
| redundancyPowerID OBJECT-TYPE The identify of power uinit. This is also the index of this table. | 1.3.6.1.4.1.2011.2.33.4.1.1.1 | INTEGER | read-only | current |
| redundancyPowerStatus OBJECT-TYPE The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail' | 1.3.6.1.4.1.2011.2.33.4.1.1.2 | INTEGER {space(1), normal(2), fail(3)} | read-only | current |
| redundancyPowerPreviousStatus OBJECT-TYPE The last status of every redundancy power unit | 1.3.6.1.4.1.2011.2.33.4.1.1.3 | INTEGER {space(1), normal(2), fail(3)} | read-only | current |
| powerTraps OBJECT-IDENTITY | 1.3.6.1.4.1.2011.2.33.4.2 | |||
| redundancyFan OBJECT-IDENTITY | 1.3.6.1.4.1.2011.2.33.5 | |||
| redundancyFanTable OBJECT-TYPE The table describles the attributes of every power unit. | 1.3.6.1.4.1.2011.2.33.5.1 | not-accessible | current | |
| redundancyFanEntry OBJECT-TYPE Each entry contains the attributes associated with a single power unit entity. | 1.3.6.1.4.1.2011.2.33.5.1.1 | not-accessible | current | |
| redundancyFanID OBJECT-TYPE The identify of power uinit. This is also the index of this table. | 1.3.6.1.4.1.2011.2.33.5.1.1.1 | INTEGER | read-only | current |
| redundancyFanStatus OBJECT-TYPE The status of every redundancy power unit. if power unit doesn't exists, take the value 'space'; if power unit is present and normal, take the value 'narmal' if power unit is present but fail, take the value 'fail' | 1.3.6.1.4.1.2011.2.33.5.1.1.2 | INTEGER {normal(1), fail(2)} | read-only | current |
| fanTraps OBJECT-IDENTITY | 1.3.6.1.4.1.2011.2.33.5.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| powerStatusChangedTrap NOTIFICATION-TYPE This trap is generated when the satus of a power unit is changed. | 1.3.6.1.4.1.2011.2.33.4.2.1 | current |
| fanStatusChangedTrap NOTIFICATION-TYPE This trap is generated when the satus of a power unit is changed. | 1.3.6.1.4.1.2011.2.33.5.2.1 | current |