MIBs Depot

HUAWEI-POS-MIB

Registered at
1.3.6.1.4.1.2011.2.33.8
Last updated
2004-10-15 00:00
Organization
Huawei-3Com Tech, Inc.
Revisions
2004-10-12 00:00, 2004-07-02 00:00
Namespace
huawei
Source file
HUAWEI-POS-MIB
Digest
sha256:cb8702d996e5b63888a329d8266e68e0fbe0a586fb56e77d17d299c10e465d9e

Description

The POS MIB module is used to manage POS-Access.

Contact

Cai Zibin, 01541. H3C PLAT APPLICATION, SOFTWARE. E-mail: zibinc@huawei-3com.com

Imports

FromSymbols
HUAWEI-3COM-OID-MIBhuawei, mlsr
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HUAWEI-3COM-OID-MIB
HUAWEI-POS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
posAppTable
OBJECT-TYPE
The table to get and set the application informatin.
1.3.6.1.4.1.2011.2.33.8.1not-accessiblecurrent
posAppEntry
OBJECT-TYPE
The content of posAppTable.
1.3.6.1.4.1.2011.2.33.8.1.1not-accessiblecurrent
posAppId
OBJECT-TYPE
The ID of application.
1.3.6.1.4.1.2011.2.33.8.1.1.1INTEGER (0..31)read-onlycurrent
posAppConnectMode
OBJECT-TYPE
The connect mode of application. If the router and unix are connected by TCP protocol, the connect mode of application is tcp. If the router and unix are connected by async interface, the connect mode of application is flow. If the router is used as POSPAD device, the connect mode of application is pad.
1.3.6.1.4.1.2011.2.33.8.1.1.2INTEGER {tcp(1), flow(2), pad(3)}read-createcurrent
posAppState
OBJECT-TYPE
The state of application.
1.3.6.1.4.1.2011.2.33.8.1.1.3INTEGER {noset(1), down(2), up(3), ok(4), kept(5), linking(6), linked(7)}read-onlycurrent
posAppIfIndex
OBJECT-TYPE
The interface index of the application whose connect mode is flow or pad.
1.3.6.1.4.1.2011.2.33.8.1.1.4INTEGER (0..2147483647)read-createcurrent
posAppHostIP
OBJECT-TYPE
The destination IP Address of application. Used for the application whose connect mode is tcp.
1.3.6.1.4.1.2011.2.33.8.1.1.5IpAddressread-createcurrent
posAppPort
OBJECT-TYPE
The destination port of application. Used for the application whose connect mode is tcp.
1.3.6.1.4.1.2011.2.33.8.1.1.6INTEGER (0..65535)read-createcurrent
posAppSourceIp
OBJECT-TYPE
The source IP Address of application. Used for the application whose connect mode is tcp.
1.3.6.1.4.1.2011.2.33.8.1.1.7IpAddressread-createcurrent
posAppRecvPacCounter
OBJECT-TYPE
The number of packets received by the application.
1.3.6.1.4.1.2011.2.33.8.1.1.8Counter32read-onlycurrent
posAppErrPacCounter
OBJECT-TYPE
The number of error packets received by the application.
1.3.6.1.4.1.2011.2.33.8.1.1.9Counter32read-onlycurrent
posAppDistrErrCounter
OBJECT-TYPE
The number of packets that could not be sent to POS.
1.3.6.1.4.1.2011.2.33.8.1.1.10Counter32read-onlycurrent
posAppBuffedCounter
OBJECT-TYPE
The number of packets stored in the buffer of application.
1.3.6.1.4.1.2011.2.33.8.1.1.11Counter32read-onlycurrent
posAppDiscardedCounter
OBJECT-TYPE
The number of packets discarded by the application.
1.3.6.1.4.1.2011.2.33.8.1.1.12Counter32read-onlycurrent
posAppDebug
OBJECT-TYPE
The debugging switch of application.
1.3.6.1.4.1.2011.2.33.8.1.1.13INTEGER {close(1), open(2)}read-createcurrent
posAppRowStatus
OBJECT-TYPE
The status of row. Only support active, CreateAndGo and destroy.
1.3.6.1.4.1.2011.2.33.8.1.1.14RowStatusread-createcurrent
posAppX121Addr
OBJECT-TYPE
The destination X121 Address of application which is an octet string made up of numeric. Used for the application whose connect mode is pad.
1.3.6.1.4.1.2011.2.33.8.1.1.15OCTET STRING (SIZE(1..15))read-createcurrent
posInterTable
OBJECT-TYPE
The table to get and set the POS-Interface informatin.
1.3.6.1.4.1.2011.2.33.8.2not-accessiblecurrent
posInterEntry
OBJECT-TYPE
The content of posInterTable.
1.3.6.1.4.1.2011.2.33.8.2.1not-accessiblecurrent
posPosId
OBJECT-TYPE
The ID of the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.1INTEGER (0..255)read-onlycurrent
posPosIfIndex
OBJECT-TYPE
The interface index of the POS-Interface whose type is fcm, asy or pad-client.
1.3.6.1.4.1.2011.2.33.8.2.1.2INTEGER (1..2147483647)read-createcurrent
posPosConnectState
OBJECT-TYPE
The state of the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.3INTEGER {noset(1), down(2), up(3), ok(4)}read-onlycurrent
posPosRecvPacCounter
OBJECT-TYPE
The number of packets received by the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.4Counter32read-onlycurrent
posPosErrPacCounter
OBJECT-TYPE
The number of error packets received by the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.5Counter32read-onlycurrent
posPosMapErrCounter
OBJECT-TYPE
The number of packets that could not be sent to application.
1.3.6.1.4.1.2011.2.33.8.2.1.6Counter32read-onlycurrent
posPosBuffedCounter
OBJECT-TYPE
The number of packets stored in the buffer of the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.7Counter32read-onlycurrent
posPosDiscardedCounter
OBJECT-TYPE
The number of packets discarded by the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.8Counter32read-onlycurrent
posPosInterDebug
OBJECT-TYPE
The debugging switch of the POS-Interface.
1.3.6.1.4.1.2011.2.33.8.2.1.9INTEGER {close(1), open(2)}read-createcurrent
posPosInterRowStatus
OBJECT-TYPE
The status of row. Only support active, CreateAndGo and destroy.
1.3.6.1.4.1.2011.2.33.8.2.1.10RowStatusread-createcurrent
posPosInterType
OBJECT-TYPE
The type of interface. The POS-Access mode has four types: FCM-Access, ASYNC-Access, simulating POSPAD device, POSPAD-Access. FCM-Access mode means POS and router are connected through PSTN. In this case, posPosInterType should be set to fcm. ASYNC-Access mode means POS and router are connected by asynchronous cable. In this case, posPosInterType should be set to asy. Simulating POSPAD device means router connects POS through asynchronous cable and connects another router whose connect mode is pad-server through X.25 network. In this case, posPosInterType should be set to pad-client. POSPAD-Access mode means router connects POSPAD device through X.25 network. In this case, posPosInterType is pad-server. The posPosInterType can't be set to pad-server. It is autogenerated when POSPAD device initiates a connection to the router.
1.3.6.1.4.1.2011.2.33.8.2.1.11INTEGER {fcm(1), asy(2), pad-client(3), pad-server(4)}read-createcurrent
posMapTable
OBJECT-TYPE
The table to get and set the informatin of mapping relation of destination and application.
1.3.6.1.4.1.2011.2.33.8.3not-accessiblecurrent
posMapEntry
OBJECT-TYPE
The content of posMapTable.
1.3.6.1.4.1.2011.2.33.8.3.1not-accessiblecurrent
posMapDes
OBJECT-TYPE
The destination code of the mapping item. If the value is -1, it is the default item of mapping relation.
1.3.6.1.4.1.2011.2.33.8.3.1.1INTEGER (-1..65535)read-createcurrent
posMapAppNumber
OBJECT-TYPE
The application index of the mapping item.
1.3.6.1.4.1.2011.2.33.8.3.1.2INTEGER (0..31)read-createcurrent
posMapRowStatus
OBJECT-TYPE
The status of row. Only support active, CreateAndGo and destroy.
1.3.6.1.4.1.2011.2.33.8.3.1.3RowStatusread-createcurrent
posAsyAppTable
OBJECT-TYPE
The table to get and set the asynchronous-application interface information.
1.3.6.1.4.1.2011.2.33.8.4not-accessiblecurrent
posAsyAppEntry
OBJECT-TYPE
The content of posAsyAppTable.
1.3.6.1.4.1.2011.2.33.8.4.1not-accessiblecurrent
posAsyAppIfIndex
OBJECT-TYPE
The interface index of asynchronous-application.
1.3.6.1.4.1.2011.2.33.8.4.1.1INTEGER (0..2147483647)read-onlycurrent
posAsyAppRowStatus
OBJECT-TYPE
The status of row. Only support active, CreateAndGo and destroy.
1.3.6.1.4.1.2011.2.33.8.4.1.2RowStatusread-createcurrent
posFCMTable
OBJECT-TYPE
The table to get the information of FCM interface.
1.3.6.1.4.1.2011.2.33.8.5not-accessiblecurrent
posFCMEntry
OBJECT-TYPE
The content of posFCMTable.
1.3.6.1.4.1.2011.2.33.8.5.1not-accessiblecurrent
posFCMIfIndex
OBJECT-TYPE
The index of FCM interface.
1.3.6.1.4.1.2011.2.33.8.5.1.1INTEGER (0..2147483647)read-onlycurrent
posFCMTimeoutCounter
OBJECT-TYPE
The number that modem was hung up for timeout.
1.3.6.1.4.1.2011.2.33.8.5.1.3Counter32read-onlycurrent
posFCMConnectFailCounter
OBJECT-TYPE
The number that modem could not handshake successfully.
1.3.6.1.4.1.2011.2.33.8.5.1.4Counter32read-onlycurrent
posAppSum
OBJECT-TYPE
The total of configued applications.
1.3.6.1.4.1.2011.2.33.8.6INTEGER (0..32)read-onlycurrent
posInterSum
OBJECT-TYPE
The total of configued POS-Interfaces.
1.3.6.1.4.1.2011.2.33.8.7INTEGER (0..256)read-onlycurrent
posEnable
OBJECT-TYPE
To enable or diable pos-server.
1.3.6.1.4.1.2011.2.33.8.8INTEGER {disable(1), enable(2)}read-writecurrent
posAppDebugAll
OBJECT-TYPE
To open or close the debugging switch of all applications.
1.3.6.1.4.1.2011.2.33.8.9INTEGER {close(1), open(2)}read-writecurrent
posPosDebugAll
OBJECT-TYPE
To open or close the debugging switch of all POS-Interfaces.
1.3.6.1.4.1.2011.2.33.8.10INTEGER {close(1), open(2)}read-writecurrent
posClearPacCounter
OBJECT-TYPE
To reset all packet counters of all applicaions and POS-Interfaces.
1.3.6.1.4.1.2011.2.33.8.11INTEGER {clear(1), counting(2)}read-writecurrent
posClearFCMCounter
OBJECT-TYPE
To clear all counters of all FCM interfaces.
1.3.6.1.4.1.2011.2.33.8.12INTEGER {clear(1), counting(2)}read-writecurrent
posEnableTrap
OBJECT-TYPE
To enable or disable trap switch.
1.3.6.1.4.1.2011.2.33.8.13INTEGER {disable(1), enable(2)}read-writecurrent
posFCMAnswerTime
OBJECT-TYPE
FCM answer time, unit:ms.
1.3.6.1.4.1.2011.2.33.8.14INTEGER (500..2000)read-writecurrent
posFCMTradeTime
OBJECT-TYPE
FCM trade time, unit:ms.
1.3.6.1.4.1.2011.2.33.8.15INTEGER (30000..1200000)read-writecurrent
posFCMPacketInterval
OBJECT-TYPE
FCM packet interval time, unit:ms.
1.3.6.1.4.1.2011.2.33.8.16INTEGER (3500..10000)read-writecurrent
posTrap
OBJECT-IDENTITY
1.3.6.1.4.1.2011.2.33.8.17
posPadWaitTime
OBJECT-TYPE
The time that POS-Interface needs to wait to receive another packet, unit:ms. It may be configured when router is used as POSPAD device. In other cases, It is useless.
1.3.6.1.4.1.2011.2.33.8.18INTEGER (100..10000)read-writecurrent
posPadIdleTimeout
OBJECT-TYPE
If these is no packet transmitting through the time, the connection of POSPAD device and router whose connect mode is pad-server will be cut off. Unit:s.
1.3.6.1.4.1.2011.2.33.8.19INTEGER (0..600)read-writecurrent
posPadPacType
OBJECT-TYPE
The type of packet.Between POSPAD device and router whose connect mode is pad-server, there are two types of packet. One is synchronous, the other is asynchronous.
1.3.6.1.4.1.2011.2.33.8.20INTEGER {syn(1), asy(2)}read-writecurrent
posPadCheckSChar
OBJECT-TYPE
To enable or disable the checking of 10 04 characters in packet. It is used for the router which is used as POSPAD device. When the value is disable, it will check packet that just includes 10 04 charaters. If there are 10 04 packet, the router which is used as POSPAD device will disconnect from POSPAD-access router. When the value is enable, it will check 10 04 characters in packet. If there are 10 04 characters in packet, the router which is used as POSPAD device will disconnect from POSPAD-access router.
1.3.6.1.4.1.2011.2.33.8.21INTEGER {disable(1), enable(2)}read-writecurrent
posPadTable
OBJECT-TYPE
The table to enable or disable POSPAD-Access function under serial interface.
1.3.6.1.4.1.2011.2.33.8.22not-accessiblecurrent
posPadEntry
OBJECT-TYPE
The content of posPadTable.
1.3.6.1.4.1.2011.2.33.8.22.1not-accessiblecurrent
posPadIfIndex
OBJECT-TYPE
The index of serial interface.
1.3.6.1.4.1.2011.2.33.8.22.1.1INTEGER (1..2147483647)not-accessiblecurrent
posPadRowStatus
OBJECT-TYPE
The status of row. Only support active, CreateAndGo and destroy.
1.3.6.1.4.1.2011.2.33.8.22.1.2RowStatusread-createcurrent

Notifications

NameOIDStatus
posAppNotReadyTrap
NOTIFICATION-TYPE
The agent will send a trap when the application whose state is linked isn't ready to send or receive data. Only used for the application whose connect mode is tcp.
1.3.6.1.4.1.2011.2.33.8.17.1current
posAppConnectFailTrap
NOTIFICATION-TYPE
The agent will send a trap if router can not connect to the application.
1.3.6.1.4.1.2011.2.33.8.17.2current
posAppStateChangeTrap
NOTIFICATION-TYPE
The agent will send a trap when the state of the application is changed to down or kept.
1.3.6.1.4.1.2011.2.33.8.17.3current
posAppNotConfigedTrap
NOTIFICATION-TYPE
The agent will send a trap if the application isn't configured.
1.3.6.1.4.1.2011.2.33.8.17.4current
posAppBuffOverFlowTrap
NOTIFICATION-TYPE
The agent will send a trap if the application buffer is overflowed.
1.3.6.1.4.1.2011.2.33.8.17.5current
posAppDebugOpenTrap
NOTIFICATION-TYPE
The agent will send a trap if the debugging switch of application is open.
1.3.6.1.4.1.2011.2.33.8.17.6current
posAppDebugAllOpenTrap
NOTIFICATION-TYPE
The agent will send a trap if the all debugging switches of application are open.
1.3.6.1.4.1.2011.2.33.8.17.7current
posInterBuffOverFlowTrap
NOTIFICATION-TYPE
The agent will send a trap if the distributing buffer is overflowed.
1.3.6.1.4.1.2011.2.33.8.17.8current
posInterStateChangeTrap
NOTIFICATION-TYPE
The agent will send a trap if the state of POS-Interface is changed to down.
1.3.6.1.4.1.2011.2.33.8.17.9current
posInterDebugOpenTrap
NOTIFICATION-TYPE
The agent will send a trap if the debug of POS-Interface is open.
1.3.6.1.4.1.2011.2.33.8.17.10current
posInterDebugAllOpenTrap
NOTIFICATION-TYPE
The agent will send a trap if the all debugs of POS-Interface are open.
1.3.6.1.4.1.2011.2.33.8.17.11current
posFCMTimeoutTrap
NOTIFICATION-TYPE
The agent will send a trap if the modem is hung up for timeout.
1.3.6.1.4.1.2011.2.33.8.17.12current
posFCMConnectFailTrap
NOTIFICATION-TYPE
The agent will send a trap if the handshaking of modems is not successful.
1.3.6.1.4.1.2011.2.33.8.17.13current
posClearPacketCounter
NOTIFICATION-TYPE
The agent will send a trap when the packet counter of the POS application and interface is cleared.
1.3.6.1.4.1.2011.2.33.8.17.14current
posClearFcmCounter
NOTIFICATION-TYPE
The agent will send a trap when the FCM counter is cleared.
1.3.6.1.4.1.2011.2.33.8.17.15current