MIBs Depot

HUAWEI-MPLSOAM-PS-MIB

Registered at
1.3.6.1.4.1.2011.5.12.7.1.3
1.3.6.1.4.1.2011.5.12.7.1.4
1.3.6.1.4.1.2011.5.12.7.1.100
Namespace
huawei
Source file
HUAWEI-MPLSOAM-PS-MIB
Digest
sha256:799b35da3245a61ab44476df715398849425e3b99f0fabf2bb879a37d54f3543

Imports

FromSymbols
HUAWEI-MPLSOAM-MIBhwMplsOam
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HUAWEI-MIB
HUAWEI-MPLSOAM-MIB
HUAWEI-MPLSOAM-PS-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hwMplsOamPs
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.12.7.1
hwMplsPsObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.12.7.1.3
hwMplsPsTable
OBJECT-TYPE
This table specifies per-protection-group MPLS PS capability and associated information.
1.3.6.1.4.1.2011.5.12.7.1.3.1not-accessiblecurrent
hwMplsPsEntry
OBJECT-TYPE
An entry in this table is created by an LSR for every protection group capable of supporting mpls ps.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1not-accessiblecurrent
hwMplsPsIndex
OBJECT-TYPE
This is a unique index for an entry in the mplspsEntry.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.1Unsigned32read-onlycurrent
hwMplsPsType
OBJECT-TYPE
The type of protection switch,can be 1:1,1+1,shared mesh, packet 1+1,the default choice is 1:1. In the 1+1 architecture type, a protection LSP is dedicated to each working LSP with the working LSP bridged onto the protection LSP at the source of the protection domain. The traffic on working and protection LSPs is transmitted simultaneously to the sink of the protection domain, where a selection between the working and protection LSP is made, based on some predetermined criteria, such as defect indication. In the 1:1 architecture type, a protection LSP is dedicated to each working LSP. The working traffic is transmitted either by working or protection LSP. In the shared mesh architecture type, possible sharing of protection capacity between disjoint link, node in the network is achieved while guaranteeing recovery from a single failure. In the packet 1+1 architecture type, the traffic is transmitted simultaneously onto two possibly disjoint routed LSPs to the sink of the protection domain. Each pair of duplicate transmitted packets is assigned the same identifier (sequence number) but distinct from the other pairs of duplicate packets. At the sink of the protection domain packet level selection mechanism is employed to select one of the two possibly received copies of each packet. 1: 1:1 protection switching,; 2: 1+1 protection switching; 3: shared mesh protection swiching; 4: packet 1+1 protection switching.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.2Integer32 (1..4)read-onlycurrent
hwMplsPsWorkTunnName
OBJECT-TYPE
The name of work-tunnel.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.3OCTET STRINGread-createcurrent
hwMplsPsWorkTunnId
OBJECT-TYPE
Work-tunnel id(session-tunnel-id).
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.4Integer32 (1..65535)read-onlycurrent
hwMplsPsProtectTunnName
OBJECT-TYPE
The name of protect-tunnel.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.5OCTET STRINGread-onlycurrent
hwMplsPsProtectTunnId
OBJECT-TYPE
Protect-tunnel id(session-tunnel-id).
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.6Integer32 (1..65535)read-onlycurrent
hwMplsPsRevertiveMode
OBJECT-TYPE
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired.And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.7Integer32 (1..2)read-onlycurrent
hwMplsPsWTR
OBJECT-TYPE
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP,It prevents reversion back to select the working LSP until the Wait to Restore timer has expired.The default value is 12 minutes.step is 30s.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.8Integer32 (0..60)read-onlycurrent
hwMplsPsHoldOff
OBJECT-TYPE
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. step is 100ms.maximum is 10s.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.9Integer32 (0..100)read-onlycurrent
hwMplsPsSwitchCondition
OBJECT-TYPE
The current switch condition of the protection group. 1: clear,This command clears all of the externally initiated switch commands listed below; 2: lockout of protection,Fix the selector position on the working LSP,Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection,Switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail,for 1:1,Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp,Switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp,Switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer; 8: HoldOff-timer; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.10Integer32 (1..9)read-writecurrent
hwMplsPsWorkTunnelState
OBJECT-TYPE
The state of working tunnel state in one protection group, whether it is in detection, 1: it is outof defect 2: it enters defect
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.11Integer32 (1..2)read-onlycurrent
hwMplsPsProtTunnelState
OBJECT-TYPE
The state of protection tunnel state in one protection group, whether it is in detection, 1: it is outof defect 2: it enters defect
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.12Integer32 (1..2)read-onlycurrent
hwMplsPsSwitchResult
OBJECT-TYPE
Which tunnel is used to transfer the data stream. 1: working-tunnel 2: protection-tunnel
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.13Integer32 (1..2)read-onlycurrent
hwMplsPsCfgType
OBJECT-TYPE
The type of protection switch which is configured. 1: 1:1 2: 1+1 3: shared mesh 4: packet 1:1
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.14Integer32 (1..2)read-onlycurrent
hwMplsPsCfgProtectTunnId
OBJECT-TYPE
Protect-tunnel id(session-tunnel-id).
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.15Integer32 (1..65535)read-createcurrent
hwMplsPsCfgRevertiveMode
OBJECT-TYPE
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired.And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.16Integer32 (1..2)read-createcurrent
hwMplsPsCfgWTR
OBJECT-TYPE
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP,It prevents reversion back to select the working LSP until the Wait to Restore timer has expired.The default value is 12 minutes.step is 30s.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.17Integer32 (0..60)read-createcurrent
hwMplsPsCfgHoldOff
OBJECT-TYPE
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. step is 100ms.maximum is 10s.
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.18Integer32 (0..100)read-writecurrent
hwMplsPsRowStatus
OBJECT-TYPE
This variable is used to create, modify, and delete a row in this table. 1: active 2: not in service 3: not ready 4: create and go 5: create and wait 6: destroy
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.19RowStatusread-writecurrent
hwTunnPsTrapOpen
OBJECT-TYPE
1:enable; 2:disable;
1.3.6.1.4.1.2011.5.12.7.1.3.2Unsigned32 (1..2)read-writecurrent
hwMplsVCPsTable
OBJECT-TYPE
Description.
1.3.6.1.4.1.2011.5.12.7.1.3.3not-accessiblecurrent
hwMplsVCPsEntry
OBJECT-TYPE
this table for these commands 1.mpls te protection tunnel XXX 2. mpls te reverse-lsp { lsp-name XXXX | lsr-id X.X.X.X tunnel-id x } 3. mpls te reserved-for-binding
1.3.6.1.4.1.2011.5.12.7.1.3.3.1not-accessiblecurrent
hwMplsVCPsIfIndex
OBJECT-TYPE
Description.the index of working tunnel interface of Protection group
1.3.6.1.4.1.2011.5.12.7.1.3.3.1.1InterfaceIndexread-onlycurrent
hwMplsVCPsTNLBinding
OBJECT-TYPE
Description.it is used by command ' mpls te reserved-for-binding '
1.3.6.1.4.1.2011.5.12.7.1.3.3.1.2TruthValueread-createcurrent
hwMplsTeReverseLspName
OBJECT-TYPE
Description.it is used for command ' mpls te reverse-lsp lspname'
1.3.6.1.4.1.2011.5.12.7.1.3.3.1.3OCTET STRINGread-createcurrent
hwMplsVcPsRowStatus
OBJECT-TYPE
Description. 1: active; 2: notInservice; 3: notReady; 4: CreateAndGo; 5: CreateAndWait; 6: destroy;
1.3.6.1.4.1.2011.5.12.7.1.3.3.1.4RowStatusread-createcurrent
hwMplsTeReverseLspLsrId
OBJECT-TYPE
Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'
1.3.6.1.4.1.2011.5.12.7.1.3.3.1.5IpAddressread-createcurrent
hwMplsTeReverseLspTunnId
OBJECT-TYPE
Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'
1.3.6.1.4.1.2011.5.12.7.1.3.3.1.6Integer32 (1..65535)read-createcurrent
hwMplsPsNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.12.7.1.4
hwMplsOamPsConformance
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.12.7.1.100
hwMplsOamPsCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.12.7.1.100.1
hwMplsOamPsGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2011.5.12.7.1.100.2

Notifications

NameOIDStatus
hwMplsPsSwitchPtoW
NOTIFICATION-TYPE
This notification is generated when switching from protection-lsp to working-lsp occured.
1.3.6.1.4.1.2011.5.12.7.1.4.1current
hwMplsPsSwitchWtoP
NOTIFICATION-TYPE
This notification is generated when switching from woking-lsp to protection-lsp occured.
1.3.6.1.4.1.2011.5.12.7.1.4.2current

Conformance

NameOIDStatus
hwMplsOamPsGroupCompliance
MODULE-COMPLIANCE
The compliance statement for mpls oam ps.
1.3.6.1.4.1.2011.5.12.7.1.100.1.1current
hwMplsPsGroup
OBJECT-GROUP
The compliance statement for mpls oam ps management.
1.3.6.1.4.1.2011.5.12.7.1.100.2.1current
hwMplsVcPsGroup
OBJECT-GROUP
The compliance statement for mpls oam ps reverse lsp.
1.3.6.1.4.1.2011.5.12.7.1.100.2.2current
hwMplsPsNotificationGroup
NOTIFICATION-GROUP
Description.
1.3.6.1.4.1.2011.5.12.7.1.100.2.3current