HUAWEI-LswMix-MIB

Registered at
1.3.6.1.4.1.2011.2.23.1.17
Last updated
2001-06-29 00:00
Revisions
2001-06-29 00:00
Namespace
huawei
Source file
HUAWEI-LswMix-MIB
Digest
sha256:f42992fbf2a11c3ae1ca2ada207fe8d3b82643724abd68bf988d79d52f45e29b

Imports

FromSymbols
HUAWEI-3COM-OID-MIBlswCommon
HUAWEI-LSW-DEV-ADM-MIBhwLswFrameIndex, hwLswSlotIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HUAWEI-3COM-OID-MIB
HUAWEI-LSW-DEV-ADM-MIB
HUAWEI-LswMix-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hwLswLastSwitchDate
OBJECT-TYPE
This object indicates the date of the most recent change to the mpu(Main Processing Unit).
1.3.6.1.4.1.2011.2.23.1.17.1INTEGERread-onlycurrent
hwLswLastSwitchTime
OBJECT-TYPE
This object indicates the time of the most recent change to the mpu.
1.3.6.1.4.1.2011.2.23.1.17.2INTEGERread-onlycurrent
hwLswMpuSwitchsNum
OBJECT-TYPE
This object indicates the total times of the mpu switched since the system start up.
1.3.6.1.4.1.2011.2.23.1.17.3INTEGERread-onlycurrent
hwLswMpuSwitch
OBJECT-TYPE
Setting this object will immediately switch the standby mpu to master mpu. Read is not supported.
1.3.6.1.4.1.2011.2.23.1.17.4INTEGER {switch(1)}read-writecurrent
hwLswXSlotTable
OBJECT-TYPE
The source main table.
1.3.6.1.4.1.2011.2.23.1.17.5not-accessiblecurrent
hwLswXSlotEntry
OBJECT-TYPE
An entry in the source main table.
1.3.6.1.4.1.2011.2.23.1.17.5.1not-accessiblecurrent
hwLswMainCardBoardStatus
OBJECT-TYPE
The value describes whether the board is master, standby or process. master and standby are the possible states for the mpu, while process indicates the state of lpu(Line Processing Unit)
1.3.6.1.4.1.2011.2.23.1.17.5.1.1INTEGER {master(1), standby(2), process(3)}read-onlycurrent
hwLswCrossBarStatus
OBJECT-TYPE
The value describes whether the crossbar is master or standby. It is master when it's in the master mpu board, standby when in the standby mpu. But both crossbars in mpus are master when the device in load-balance mode.
1.3.6.1.4.1.2011.2.23.1.17.5.1.2INTEGER {master(1), standby(2)}read-onlycurrent
hwsMixTrapMib
OBJECT-IDENTITY
1.3.6.1.4.1.2011.2.23.1.17.10

Notifications

NameOIDStatus
hwSlaveSwitchOver
NOTIFICATION-TYPE
An hwSlaveSwitchOver trap signifies that the action of standby mpu switching to master has completed.
1.3.6.1.4.1.2011.2.23.1.17.10.1current