HUAWEI-FR-QOS-MIB
- Registered at
- 1.3.6.1.4.1.2011.5.25.32.3
- Last updated
- 2004-07-12 00:00
- Organization
- Huawei Technologies co.,Ltd.
- Namespace
- huawei
- Source file
HUAWEI-FR-QOS-MIB- Digest
sha256:e6c395f8580a6d8e41c310ef29a8884ee25560164827cd7aac42cc017b686933
Description
The HUAWEI-FR-QOS-MIB contains objects to Manage configuration and Monitor running state for Class Based FR QoS feature. ********************************* MIB Tables ********************************** This MIB consists of the following tables: 1 : hwFrClassCfgInfoTable 2 : hwCirAllowCfgInfoTable 3 : hwCirCfgInfoTable 4 : hwIfApplyFrClassTable 5 : hwPvcApplyFrClassTable 6 : hwFrPvcBandwidthTable 7 : hwRTPFrClassApplyTable 8 : hwRTPFrPvcQueueRunInfoTable
Contact
R&D BeiJing, Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China Zip:100085 Http://www.huawei.com E-mail:support@huawei.com
Imports
| From | Symbols |
|---|---|
| HUAWEI-MIB | hwDatacomm |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HUAWEI-FR-QOS-MIB HUAWEI-MIB IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| DirectionType TEXTUAL-CONVENTION The Direction Policy apply on. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hwQoS OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.32 | |||
| hwFrQoSObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.32.3.1 | |||
| hwFrClassObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.32.3.1.1 | |||
| hwFrClassIndexNext OBJECT-TYPE This object contains an appropriate value to be used for hwFrClassIndex when creating rows in the hwFrClassCfgInfoTable. Begin with 0. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.1 | Integer32 | read-only | current |
| hwFrClassCfgInfoTable OBJECT-TYPE A table of Fr Class configuration information. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.2 | not-accessible | current | |
| hwFrClassCfgInfoEntry OBJECT-TYPE Fr Class Configuration Information Entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1 | not-accessible | current | |
| hwFrClassIndex OBJECT-TYPE Index of Fr Class. Begin with 0. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1.1 | Integer32 | read-only | current |
| hwFrClassName OBJECT-TYPE Name of Fr Class. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1.2 | OCTET STRING (SIZE(1..31)) | read-create | current |
| hwFrClassRowStatus OBJECT-TYPE RowStatus. Three actions are used: active, createAndGo, destroy | 1.3.6.1.4.1.2011.5.25.32.3.1.1.2.1.3 | RowStatus | read-create | current |
| hwCirAllowCfgInfoTable OBJECT-TYPE A table of DCE allowed rate Configuration information. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.3 | not-accessible | current | |
| hwCirAllowCfgInfoEntry OBJECT-TYPE DCE allowed ratee Configuration Information Entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1 | not-accessible | current | |
| hwCirAllowFrClassIndex OBJECT-TYPE Index of Fr Class. Begin with 0.Equal to hwFrClassIndex | 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.1 | Integer32 | read-only | current |
| hwCirAllowDirection OBJECT-TYPE Packet Direction. value 1,2,3 Used by hwCirAllowValue. inbound (1) outbound (2) inbound and outbound (3) | 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.2 | Integer32 | read-only | current |
| hwCirAllowValue OBJECT-TYPE DCE allowed rate (value greater than CIR) Unit : Bits per second. Value : <1-45000000> . | 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.3 | Integer32 (1..45000000) | read-create | current |
| hwCirAllowRowStatus OBJECT-TYPE RowStatus. Three actions are used: active, createAndGo, destroy | 1.3.6.1.4.1.2011.5.25.32.3.1.1.3.1.4 | RowStatus | read-create | current |
| hwCirCfgInfoTable OBJECT-TYPE A table of Committed Information Rate Configuration information. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.4 | not-accessible | current | |
| hwCirCfgInfoEntry OBJECT-TYPE Committed Information Rate Configuration Information Entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1 | not-accessible | current | |
| hwCirFrClassIndex OBJECT-TYPE Index of Fr Class. Begin with 0.Equal to hwFrClassIndex | 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1.1 | Integer32 | read-only | current |
| hwCirValue OBJECT-TYPE CIR in packet output direction ,bps. Value : <1000-45000000>. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1.2 | Integer32 (1000..45000000) | read-create | current |
| hwCirRowStatus OBJECT-TYPE RowStatus. Three actions are used: active, createAndGo, destroy | 1.3.6.1.4.1.2011.5.25.32.3.1.1.4.1.3 | RowStatus | read-create | current |
| hwIfApplyFrClassTable OBJECT-TYPE A table of QoS Fr Class instance. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.5 | not-accessible | current | |
| hwIfApplyFrClassEntry OBJECT-TYPE FrClass applied on interface Configuration Information Entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1 | not-accessible | current | |
| hwIfApplyFrClassIfIndex OBJECT-TYPE Interface Index, equal to ifIndex. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1.1 | Integer32 | read-only | current |
| hwIfApplyFrClassIndex OBJECT-TYPE Index of Fr Class, equal to hwFrClassIndex | 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1.2 | Integer32 | read-create | current |
| hwIfApplyFrClassRowStatus OBJECT-TYPE RowStatus. Three actions are used: active, createAndGo, destroy | 1.3.6.1.4.1.2011.5.25.32.3.1.1.5.1.3 | RowStatus | read-create | current |
| hwPvcApplyFrClassTable OBJECT-TYPE A table of QoS Fr Class instance. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.6 | not-accessible | current | |
| hwPvcApplyFrClassEntry OBJECT-TYPE Fr Class applied on FR Pvc Configuration Information Entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1 | not-accessible | current | |
| hwPvcApplyFrClassIfIndex OBJECT-TYPE Fr Interface Index, equal to ifIndex. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.1 | Integer32 | read-only | current |
| hwPvcApplyFrClassDlciNum OBJECT-TYPE Fr DLCI number. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.2 | Integer32 (16..1007) | read-only | current |
| hwPvcApplyFrClassIndex OBJECT-TYPE Index of Fr Class, equal to hwFrClassIndex | 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.3 | Integer32 | read-create | current |
| hwPvcApplyFrClassRowStatus OBJECT-TYPE RowStatus. Three actions are used: active, createAndGo, destroy | 1.3.6.1.4.1.2011.5.25.32.3.1.1.6.1.4 | RowStatus | read-create | current |
| hwFrPvcBandwidthTable OBJECT-TYPE A table of Running statistics for bandwidth. | 1.3.6.1.4.1.2011.5.25.32.3.1.1.7 | not-accessible | current | |
| hwFrPvcBandwidthEntry OBJECT-TYPE Bandwidth Running statistics | 1.3.6.1.4.1.2011.5.25.32.3.1.1.7.1 | not-accessible | current | |
| hwFrPvcBandwidthMaxReservedBW OBJECT-TYPE Max reserved bandWidth. Unit : Kbps | 1.3.6.1.4.1.2011.5.25.32.3.1.1.7.1.1 | Integer32 | read-only | current |
| hwFrPvcBandwidthAvailable OBJECT-TYPE Available bandWidth. Unit : Kbps | 1.3.6.1.4.1.2011.5.25.32.3.1.1.7.1.2 | Integer32 | read-only | current |
| hwRTPQoSObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.5.25.32.3.1.2 | |||
| hwRTPFrClassApplyTable OBJECT-TYPE A table of QoS rtpq instance. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1 | not-accessible | current | |
| hwRTPFrClassApplyEntry OBJECT-TYPE Rtpq Configuration Information Entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1 | not-accessible | current | |
| hwRTPFrClassApplyFrClassIndex OBJECT-TYPE Fr Class Index, equal to HwFrClassIndex. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.1 | Integer32 | read-only | current |
| hwRTPFrClassApplyStartPort OBJECT-TYPE RTP-PORT(3): start-port: 2000~65535 | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.2 | Integer32 (2000..65535) | read-create | current |
| hwRTPFrClassApplyEndPort OBJECT-TYPE RTP-PORT(3): end-port: 2000~65535 | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.3 | Integer32 (2000..65535) | read-create | current |
| hwRTPFrClassApplyBandWidth OBJECT-TYPE Max bandWidth Value: Absolute value: 8~1000000. Unit: Kbps | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.4 | Integer32 (8..1000000) | read-create | current |
| hwRTPFrClassApplyCbs OBJECT-TYPE Committed Burst Size: 1500~2000000. Unit: byte | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.5 | Integer32 (1500..2000000) | read-create | current |
| hwRTPFrClassApplyRowStatus OBJECT-TYPE RowStatus for RTPFrClassApply Table. Three actions are used: active, createAndGo, destroy | 1.3.6.1.4.1.2011.5.25.32.3.1.2.1.1.6 | RowStatus | read-create | current |
| hwRTPFrPvcQueueRunInfoTable OBJECT-TYPE A table of Running statistics for RTPQ Queue applied on the FR PVC | 1.3.6.1.4.1.2011.5.25.32.3.1.2.2 | not-accessible | current | |
| hwRTPFrPvcQueueRunInfoEntry OBJECT-TYPE Queue statistics entry. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1 | not-accessible | current | |
| hwRTPFrPvcQueueSize OBJECT-TYPE Size of Rtpq Queue. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.1 | Integer32 | read-only | current |
| hwRTPFrPvcQueueMaxSize OBJECT-TYPE Max size of Rtpq Queue. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.2 | Integer32 | read-only | current |
| hwRTPFrPvcQueueOutputs OBJECT-TYPE Outputs of Rtpq Queue. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.3 | Counter32 | read-only | current |
| hwRTPFrPvcQueueDiscards OBJECT-TYPE Discards of Rtpq Queue. | 1.3.6.1.4.1.2011.5.25.32.3.1.2.2.1.4 | Counter32 | read-only | current |