MIBs Depot

HPIPF02TRAP-MIB

Registered at
1.3.6.1.4.1.11.2.23.35
1.3.6.1.4.1.11.2.23.45
Namespace
hp
Source file
HPIPF02TRAP-MIB
Digest
sha256:4159924b407a6906a29c4d2b09d878f9e3e1680ba56b9c6f14eed5eadee9d1dd

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HPIPF02TRAP-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hp
OBJECT-IDENTITY
1.3.6.1.4.1.11
nm
OBJECT-IDENTITY
1.3.6.1.4.1.11.2
hpnsa
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.23
hpIpfE0Events
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.23.35
hpIpf02Events
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.23.45
hpIpfEvtDetailStr
OBJECT-TYPE
This string provides a detailed description of the Event along with variable information.
1.3.6.1.4.1.11.2.23.45.1DisplayStringread-onlymandatory

Notifications

NameOIDStatus
hpTemperature4
NOTIFICATION-TYPE
One of the temperature sensors crossed its upper non-critical threshold.
1.3.6.1.4.1.11.2.23.45.0.4
hpTemperature5
NOTIFICATION-TYPE
One of the temperature sensors crossed its upper critical threshold.
1.3.6.1.4.1.11.2.23.45.0.5
hpTemperature6
NOTIFICATION-TYPE
One of the temperature sensors crossed its upper non-recoverable threshold.
1.3.6.1.4.1.11.2.23.45.0.6
hpEnvironment8
NOTIFICATION-TYPE
One of the voltage sensors crossed its lower critical threshold.
1.3.6.1.4.1.11.2.23.45.0.8
hpEnvironment9
NOTIFICATION-TYPE
One of the voltage sensors crossed its lower non-recoverable threshold.
1.3.6.1.4.1.11.2.23.45.0.9
hpEnvironment10
NOTIFICATION-TYPE
One of the voltage sensors crossed its upper non-critical threshold.
1.3.6.1.4.1.11.2.23.45.0.10
hpEnvironment12
NOTIFICATION-TYPE
One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.0.12
hpChassis26
NOTIFICATION-TYPE
The chassis has been opened.
1.3.6.1.4.1.11.2.23.45.0.26
hpSystemHW113
NOTIFICATION-TYPE
A SCSI cable has been removed from the hot swap cage.
1.3.6.1.4.1.11.2.23.45.0.113
hpECCMemory518
NOTIFICATION-TYPE
Uncorrectable multi-bit ECC error has occurred in memory module
1.3.6.1.4.1.11.2.23.45.0.518
hpSystemFW699
NOTIFICATION-TYPE
Machine Check Initiated
1.3.6.1.4.1.11.2.23.45.0.699
hpSystemFW700
NOTIFICATION-TYPE
System firmware error
1.3.6.1.4.1.11.2.23.45.0.700
hpEnvironment704
NOTIFICATION-TYPE
Voltage fault - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.0.704
hpEnvironment705
NOTIFICATION-TYPE
Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.0.705
hpEnvironment706
NOTIFICATION-TYPE
Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.0.706
hpEnvironment707
NOTIFICATION-TYPE
Voltage absent
1.3.6.1.4.1.11.2.23.45.0.707
hpFan710
NOTIFICATION-TYPE
Fan speed lags
1.3.6.1.4.1.11.2.23.45.0.710
hpRedundantPower720
NOTIFICATION-TYPE
Power supply failed or disconnected
1.3.6.1.4.1.11.2.23.45.0.720
hpRedundantPower722
NOTIFICATION-TYPE
Power supply AC lost
1.3.6.1.4.1.11.2.23.45.0.722
hpPowerSupply726
NOTIFICATION-TYPE
A/C Failed, disconnected, or out of range
1.3.6.1.4.1.11.2.23.45.0.726
hpEnvironment728
NOTIFICATION-TYPE
Voltage degraded to critical level from less severe - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.0.728
hpSystemHW729
NOTIFICATION-TYPE
System shut-down or reset caused by sensor reading.
1.3.6.1.4.1.11.2.23.45.0.729
hpBmcFirmware730
NOTIFICATION-TYPE
The BMC firmware did not detect the system firmware boot.
1.3.6.1.4.1.11.2.23.45.0.730
hpPowerSupply731
NOTIFICATION-TYPE
A/C Failed, disconnected, or out of range
1.3.6.1.4.1.11.2.23.45.0.731
hpRedundantPower732
NOTIFICATION-TYPE
The Power supply's sensors detect possible problems
1.3.6.1.4.1.11.2.23.45.0.732
hpSystemHW733
NOTIFICATION-TYPE
Cooling unit warning
1.3.6.1.4.1.11.2.23.45.0.733
hpSystemHW734
NOTIFICATION-TYPE
Cooling unit failure
1.3.6.1.4.1.11.2.23.45.0.734
hpSystemHW735
NOTIFICATION-TYPE
BMC entering special mode
1.3.6.1.4.1.11.2.23.45.0.735
hpSystemHW736
NOTIFICATION-TYPE
Watchdog timer expired - hard reset
1.3.6.1.4.1.11.2.23.45.0.736
hpSystemHW737
NOTIFICATION-TYPE
Watchdog timer expired - power-off
1.3.6.1.4.1.11.2.23.45.0.737
hpSystemHW738
NOTIFICATION-TYPE
Watchdog timer expired - power-cycle
1.3.6.1.4.1.11.2.23.45.0.738
hpSystemHW739
NOTIFICATION-TYPE
Missing FRU device
1.3.6.1.4.1.11.2.23.45.0.739
hpSystemHW740
NOTIFICATION-TYPE
Missing Entity
1.3.6.1.4.1.11.2.23.45.0.740
hpSystemHW744
NOTIFICATION-TYPE
System event log almost full
1.3.6.1.4.1.11.2.23.45.0.744
hpSystemHW745
NOTIFICATION-TYPE
TOC interrupt (crash dump)
1.3.6.1.4.1.11.2.23.45.0.745
hpSystemHW746
NOTIFICATION-TYPE
INIT Initiated
1.3.6.1.4.1.11.2.23.45.0.746
hpSystemHW747
NOTIFICATION-TYPE
PCI system error detected
1.3.6.1.4.1.11.2.23.45.0.747
hpSystemHW748
NOTIFICATION-TYPE
OS run-time critical shutdown
1.3.6.1.4.1.11.2.23.45.0.748
hpSystemHW749
NOTIFICATION-TYPE
ACPI state S5 (soft-off, entered by override)
1.3.6.1.4.1.11.2.23.45.0.749
hpSystemHW751
NOTIFICATION-TYPE
PCI parity error detected
1.3.6.1.4.1.11.2.23.45.0.751
hpTempHighWarning752
NOTIFICATION-TYPE
One of the temperature sensors crossed its lower non-critical threshold.
1.3.6.1.4.1.11.2.23.45.0.752
hpTempHighCritical753
NOTIFICATION-TYPE
One of the temperature sensors crossed its upper critical threshold.
1.3.6.1.4.1.11.2.23.45.0.753
hpTempHighNonRecoverable754
NOTIFICATION-TYPE
One of the temperature sensors crossed its upper non-recoverable threshold.
1.3.6.1.4.1.11.2.23.45.0.754
hpTemperature755
NOTIFICATION-TYPE
A temperature inside the server has gone outside the factory specified range.
1.3.6.1.4.1.11.2.23.45.0.755
hpTemperature756
NOTIFICATION-TYPE
One of the temperature sensors crossed its upper critical threshold.
1.3.6.1.4.1.11.2.23.45.0.756
hpRedundantPower757
NOTIFICATION-TYPE
The Power Supply AC voltage was lost or is out of range.
1.3.6.1.4.1.11.2.23.45.0.757
hpRedundantPower758
NOTIFICATION-TYPE
The AC voltage connected to the power supply is out of range.
1.3.6.1.4.1.11.2.23.45.0.758