Description

This MIB defines HP proprietary objects used to configure the TR-069 feature.

Contact

Hewlett-Packard Company 8000 Foothills Blvd. Roseville, CA 95747

Imports

FromSymbols
HP-ICF-OIDhpSwitch
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HP-ICF-OID
HPICF-TR069-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hpicfTR069Notifications
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.98.0
hpicfTR069Objects
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.98.1
hpicfTR069EnableCWMP
OBJECT-TYPE
Enable TR-069 on the device.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.1INTEGER {disable(1), enable(2)}read-writecurrent
hpicfTR069CWMPDeviceType
OBJECT-TYPE
The working mode of the device. By default, the device operates in gateway mode. CWMP should be disabled before changing modes.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.2INTEGER {device(1), gateway(2)}read-writecurrent
hpicfTR069AcsUrl
OBJECT-TYPE
The URL used by TR-069 to connect to the ACS. The value should be a valid HTTP or HTTPS URL.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.3OCTET STRING (SIZE(0..256))read-writecurrent
hpicfTR069AcsUrlOrigin
OBJECT-TYPE
The source of the ACS URL. none - no ACS URL set config - from the device configuration file dhcp - from a DHCP server response acs - from the ACS itself
1.3.6.1.4.1.11.2.14.11.5.1.98.1.4INTEGER {none(1), config(2), dhcp(3), acs(4)}read-onlycurrent
hpicfTR069AcsProxyUrl
OBJECT-TYPE
The URL used by TR-069 to connect to a proxy server in order to reach the ACS. The value should be a valid HTTP or HTTPS URL.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.5OCTET STRING (SIZE(0..256))read-writecurrent
hpicfTR069AcsUsername
OBJECT-TYPE
The username for HTTP authentication with the ACS.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.6OCTET STRING (SIZE(0..256))read-writecurrent
hpicfTR069AcsPassword
OBJECT-TYPE
The plaintext password for HTTP authentication with the ACS. This object always returns an empty string when read.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.7OCTET STRING (SIZE(0..256))read-writecurrent
hpicfTR069AcsPasswordEncrypted
OBJECT-TYPE
An encrypted form of the ACS password. The value should be an encrypted password previously read from a compatible HP Networking device. This object can only be read or written when hpSwitchAuthenticationEncryptCredentialsMethod is set to a value other than 'none' and cannot be set at the same time as hpicfTR069AcsPassword.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.8OCTET STRING (SIZE(0..384))read-writecurrent
hpicfTR069AcsConnectRetryInterval
OBJECT-TYPE
The ACS connection retry interval.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.9Unsigned32read-onlycurrent
hpicfTR069CpeUsername
OBJECT-TYPE
The username for HTTP authentication with the TR-069 client.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.10OCTET STRING (SIZE(0..256))read-writecurrent
hpicfTR069CpePassword
OBJECT-TYPE
The plaintext password for HTTP authentication with the TR-069 client. This object always returns an empty string when read.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.11OCTET STRING (SIZE(0..256))read-writecurrent
hpicfTR069CpePasswordEncrypted
OBJECT-TYPE
An encrypted form of the client password. The value should be an encrypted password previously read from a compatible HP Networking device. This object can only be read or written when hpSwitchAuthenticationEncryptCredentialsMethod is set to a value other than 'none' and cannot be set at the same time as hpicfTR069CpePassword.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.12OCTET STRING (SIZE(0..384))read-writecurrent
hpicfTR069CpeWaitTimeout
OBJECT-TYPE
The close-wait timeout of the ACS connection.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.13Unsigned32read-onlycurrent
hpicfTR069PeriodicInformEnable
OBJECT-TYPE
The periodic inform message setting specified by the ACS.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.14INTEGER {disable(1), enable(2)}read-onlycurrent
hpicfTR069PeriodicInformInterval
OBJECT-TYPE
The periodic inform interval in seconds specified by the ACS.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.15Unsigned32read-onlycurrent
hpicfTR069PeriodicInformTime
OBJECT-TYPE
The date and time to send inform messages specified by the ACS.
1.3.6.1.4.1.11.2.14.11.5.1.98.1.16DateAndTimeread-onlycurrent
hpicfTR069Conformance
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.98.2
hpicfTR069MIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.98.2.1
hpicfTR069MIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.98.2.2

Conformance

NameOIDStatus
hpicfTR069MIBCompliance
MODULE-COMPLIANCE
The compliance statement for HP switches implementing the HPICF-TR069 MIB.
1.3.6.1.4.1.11.2.14.11.5.1.98.2.1.1current
hpicfTR069Group
OBJECT-GROUP
A collection of objects to support the TR-069 feature.
1.3.6.1.4.1.11.2.14.11.5.1.98.2.2.1current