HP-OPENCALL-SS7SNMPAGENT-BASE-MIB
- Registered at
- 1.3.6.1.4.1.11.2.29.2
- Last updated
- 2004-09-09 00:00
- Organization
- Hewlett Packard Company, OpenCall Business Unit
- Revisions
- 2004-09-09 00:00, 2003-09-09 00:00
- Namespace
- hp
- Source file
HP-OPENCALL-SS7SNMPAGENT-BASE-MIB- Digest
sha256:f2da1706730fe0e945dfd536fae57b7976bfac2fbba3f84fc83f2c957600e8b2
Description
This is the MIB module that describes an HP private mib for the management of OpenCall traps.
Contact
Raymond Mercier
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HP-OPENCALL-SS7SNMPAGENT-BASE-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| openCallTraps OBJECT-IDENTITY | 1.3.6.1.4.1.11.2.29.2.0 | |||
| sourcePlatformEntity OBJECT-TYPE This is the source entity that sends the trap, typically this is a combination of platform and machine name. (ex: oc_platform, nta2225.india.hp.com | 1.3.6.1.4.1.11.2.29.2.0.1 | DisplayString | read-only | current |
| sourceObjectID OBJECT-TYPE This identifies the objectID of the instance that sends the trap. (ex: Process Name) | 1.3.6.1.4.1.11.2.29.2.0.2 | DisplayString | read-only | current |
| perceveidSeverity OBJECT-TYPE This identifies the severity of the trap. Possible severity are 1. Major 2. Minor 3. Warning 4. Informative 5. Critical | 1.3.6.1.4.1.11.2.29.2.0.3 | DisplayString | read-only | current |
| alarmText OBJECT-TYPE This describes the alarm generating the trap. | 1.3.6.1.4.1.11.2.29.2.0.4 | DisplayString | read-only | current |
| probableCause OBJECT-TYPE This identifies the probable cause of the trap. | 1.3.6.1.4.1.11.2.29.2.0.5 | DisplayString | read-only | current |
| correctiveAction OBJECT-TYPE This describes the actions to apply for correcting the problem that generated this alarm. | 1.3.6.1.4.1.11.2.29.2.0.6 | DisplayString | read-only | current |
| htimeStamp OBJECT-TYPE Time-Stamp recorded in the log generated by this alarm. | 1.3.6.1.4.1.11.2.29.2.0.7 | DisplayString | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| hHPOC_3100155 NOTIFICATION-TYPE ISUP application <number> : Continuity test failed. | 1.3.6.1.4.1.11.2.29.2.0.3100155 | current |
| hHPOC_8400042 NOTIFICATION-TYPE FTC: Peer FTC connection failure. | 1.3.6.1.4.1.11.2.29.2.0.8400042 | current |
| hHPOC_8400084 NOTIFICATION-TYPE FTC: system switch-over occurred. | 1.3.6.1.4.1.11.2.29.2.0.8400084 | current |
| hHPOC_8400085 NOTIFICATION-TYPE FTC: Active process is down. | 1.3.6.1.4.1.11.2.29.2.0.8400085 | current |
| hHPOC_8400086 NOTIFICATION-TYPE FTC: Standby process is down. | 1.3.6.1.4.1.11.2.29.2.0.8400086 | current |
| hHPOC_8400087 NOTIFICATION-TYPE FTC: Process is active. | 1.3.6.1.4.1.11.2.29.2.0.8400087 | current |
| hHPOC_8400088 NOTIFICATION-TYPE FTC: Process is hotstandby. | 1.3.6.1.4.1.11.2.29.2.0.8400088 | current |
| hHPOC_8400089 NOTIFICATION-TYPE FTC: Peer FTC connected | 1.3.6.1.4.1.11.2.29.2.0.8400089 | current |
| hHPOC_9000332 NOTIFICATION-TYPE ss7Stack-mtp: MTPL3 SYNCHRO ABORTED. | 1.3.6.1.4.1.11.2.29.2.0.9000332 | current |
| hHPOC_9000334 NOTIFICATION-TYPE ss7Stack-mtp: MTPL3 SYNCHRO ABORTED. | 1.3.6.1.4.1.11.2.29.2.0.9000334 | current |
| hHPOC_9000336 NOTIFICATION-TYPE ss7Stack-mtp: MTPL3 SYNCHRO ABORTED. | 1.3.6.1.4.1.11.2.29.2.0.9000336 | current |
| hHPOC_9000341 NOTIFICATION-TYPE ss7Stack-mtp: Link out of service. | 1.3.6.1.4.1.11.2.29.2.0.9000341 | current |
| hHPOC_9000342 NOTIFICATION-TYPE ss7Stack-mtp: Link inactive. | 1.3.6.1.4.1.11.2.29.2.0.9000342 | current |
| hHPOC_9000343 NOTIFICATION-TYPE ss7Stack-mtp: Link active. | 1.3.6.1.4.1.11.2.29.2.0.9000343 | current |
| hHPOC_9000344 NOTIFICATION-TYPE ss7Stack-mtp: Linkset out of service. | 1.3.6.1.4.1.11.2.29.2.0.9000344 | current |
| hHPOC_9000345 NOTIFICATION-TYPE ss7Stack-mtp: Linkset inactive. | 1.3.6.1.4.1.11.2.29.2.0.9000345 | current |
| hHPOC_9000346 NOTIFICATION-TYPE ss7Stack-mtp: Linkset active. | 1.3.6.1.4.1.11.2.29.2.0.9000346 | current |
| hHPOC_9000347 NOTIFICATION-TYPE ss7Stack-mtp: MTP out of service. | 1.3.6.1.4.1.11.2.29.2.0.9000347 | current |
| hHPOC_9000348 NOTIFICATION-TYPE ss7Stack-mtp: MTP active. | 1.3.6.1.4.1.11.2.29.2.0.9000348 | current |
| hHPOC_9000349 NOTIFICATION-TYPE ss7Stack-mtp: MTP inactive. | 1.3.6.1.4.1.11.2.29.2.0.9000349 | current |
| hHPOC_9000350 NOTIFICATION-TYPE ss7Stack-mtp: MTP restarting. | 1.3.6.1.4.1.11.2.29.2.0.9000350 | current |
| hHPOC_9000354 NOTIFICATION-TYPE ss7Stack-mtp: <string> user MTP3 connection closed. | 1.3.6.1.4.1.11.2.29.2.0.9000354 | current |
| hHPOC_9000355 NOTIFICATION-TYPE ss7Stack-mtp: <string> user MTP3 connection open. | 1.3.6.1.4.1.11.2.29.2.0.9000355 | current |
| hHPOC_9000356 NOTIFICATION-TYPE ss7Stack-mtp: Link outbound congestion. | 1.3.6.1.4.1.11.2.29.2.0.9000356 | current |
| hHPOC_9000357 NOTIFICATION-TYPE ss7Stack-mtp: Deletion not allowed, VPC <number> in use | 1.3.6.1.4.1.11.2.29.2.0.9000357 | current |
| hHPOC_9000635 NOTIFICATION-TYPE ss7Stack-sccp: SCCP is now deactivated and disconnected of MTP | 1.3.6.1.4.1.11.2.29.2.0.9000635 | current |
| hHPOC_9000636 NOTIFICATION-TYPE ss7Stack-sccp: SCCP is now reactivated and connected to MTP | 1.3.6.1.4.1.11.2.29.2.0.9000636 | current |
| hHPOC_9000681 NOTIFICATION-TYPE ss7Stack-sccp: Local SCCP user out of service. | 1.3.6.1.4.1.11.2.29.2.0.9000681 | current |
| hHPOC_9000682 NOTIFICATION-TYPE ss7Stack-sccp: Local SCCP user in service. | 1.3.6.1.4.1.11.2.29.2.0.9000682 | current |
| hHPOC_9001260 NOTIFICATION-TYPE ss7Stack-level2: <string>: double fan failure | 1.3.6.1.4.1.11.2.29.2.0.9001260 | current |
| hHPOC_9001262 NOTIFICATION-TYPE <string>: SIU reachable from standby. | 1.3.6.1.4.1.11.2.29.2.0.9001262 | current |
| hHPOC_9001268 NOTIFICATION-TYPE <string>: SIU out of service. | 1.3.6.1.4.1.11.2.29.2.0.9001268 | current |
| hHPOC_9001269 NOTIFICATION-TYPE <string>: SIU in service. | 1.3.6.1.4.1.11.2.29.2.0.9001269 | current |
| hHPOC_9001270 NOTIFICATION-TYPE <string>: TSU unreachable from standby. | 1.3.6.1.4.1.11.2.29.2.0.9001270 | current |
| hHPOC_9001271 NOTIFICATION-TYPE <string>: TSU reachable from standby. | 1.3.6.1.4.1.11.2.29.2.0.9001271 | current |
| hHPOC_9001272 NOTIFICATION-TYPE <string>: TSU out of service. | 1.3.6.1.4.1.11.2.29.2.0.9001272 | current |
| hHPOC_9001273 NOTIFICATION-TYPE <string>: TSU in service. | 1.3.6.1.4.1.11.2.29.2.0.9001273 | current |
| hHPOC_9001274 NOTIFICATION-TYPE <string>: TSC out of service. | 1.3.6.1.4.1.11.2.29.2.0.9001274 | current |
| hHPOC_9001275 NOTIFICATION-TYPE <string>: TSC in service. | 1.3.6.1.4.1.11.2.29.2.0.9001275 | current |
| hHPOC_9001276 NOTIFICATION-TYPE <string>: TSU fan <number> has failed | 1.3.6.1.4.1.11.2.29.2.0.9001276 | current |
| hHPOC_9001277 NOTIFICATION-TYPE <string>: TSU -48VDC input <number> has failed | 1.3.6.1.4.1.11.2.29.2.0.9001277 | current |
| hHPOC_9001278 NOTIFICATION-TYPE <string>: TSU fan <number> has recovered operation. | 1.3.6.1.4.1.11.2.29.2.0.9001278 | current |
| hHPOC_9001279 NOTIFICATION-TYPE <string>: TSU -48VDC input <number> has recovered operation | 1.3.6.1.4.1.11.2.29.2.0.9001279 | current |
| hHPOC_9001280 NOTIFICATION-TYPE <string>: SIU unreachable from standby. | 1.3.6.1.4.1.11.2.29.2.0.9001280 | current |
| hHPOC_40100001 NOTIFICATION-TYPE M3UA EP <number>: Connected to IPSP/SGP <number>. | 1.3.6.1.4.1.11.2.29.2.0.40100001 | current |
| hHPOC_40100011 NOTIFICATION-TYPE M3UA EP <number>: Association with IPSP/SGP <number> has been lost. | 1.3.6.1.4.1.11.2.29.2.0.40100011 | current |
| hHPOC_40100040 NOTIFICATION-TYPE M3UA EP <number>: SCTP listening FAILURE. Stop the M3UA stack. | 1.3.6.1.4.1.11.2.29.2.0.40100040 | current |
| hHPOC_40100501 NOTIFICATION-TYPE Failed M3UA General Configuration request for reason <number>. | 1.3.6.1.4.1.11.2.29.2.0.40100501 | current |
| hHPOC_40100502 NOTIFICATION-TYPE Stack initialization failure. | 1.3.6.1.4.1.11.2.29.2.0.40100502 | current |
| hHPOC_40100601 NOTIFICATION-TYPE M3UA EP <number>: RepMgr Service lost by the Ha Component. Graceful shutdown requested | 1.3.6.1.4.1.11.2.29.2.0.40100601 | current |
| hHPOC_40100607 NOTIFICATION-TYPE M3UA EP <number> enters flowcontrol | 1.3.6.1.4.1.11.2.29.2.0.40100607 | current |
| hHPOC_40100608 NOTIFICATION-TYPE M3UA EP <number> exits flowcontrol | 1.3.6.1.4.1.11.2.29.2.0.40100608 | current |
| hHPOC_40100801 NOTIFICATION-TYPE M3UA: Remote DPC <number> is available | 1.3.6.1.4.1.11.2.29.2.0.40100801 | current |
| hHPOC_40100802 NOTIFICATION-TYPE M3UA: Remote DPC <number> is unavailable | 1.3.6.1.4.1.11.2.29.2.0.40100802 | current |
| hHPOC_40100803 NOTIFICATION-TYPE M3UA: Remote DPC <number> is congested | 1.3.6.1.4.1.11.2.29.2.0.40100803 | current |
| hHPOC_40100804 NOTIFICATION-TYPE M3UA: Remote DPC <number> is congested at level <number> | 1.3.6.1.4.1.11.2.29.2.0.40100804 | current |
| hHPOC_40100806 NOTIFICATION-TYPE M3UA: Remote AS (DPC <number> SI <number>) is active | 1.3.6.1.4.1.11.2.29.2.0.40100806 | current |
| hHPOC_40100807 NOTIFICATION-TYPE M3UA: Remote AS (DPC <number> SI <number>) is inactive | 1.3.6.1.4.1.11.2.29.2.0.40100807 | current |
| hHPOC_40100809 NOTIFICATION-TYPE Switch transport to MTP for DPC <number> | 1.3.6.1.4.1.11.2.29.2.0.40100809 | current |
| hHPOC_40100810 NOTIFICATION-TYPE Switch transport to M3UA for DPC <number> | 1.3.6.1.4.1.11.2.29.2.0.40100810 | current |
| hHPOC_40300002 NOTIFICATION-TYPE Failed <string> request for <string> Id=<number>, error code <number> | 1.3.6.1.4.1.11.2.29.2.0.40300002 | current |
| hHPOC_40300003 NOTIFICATION-TYPE Timeout from stack on <string> request for <string> Id=<number>, error code <number> | 1.3.6.1.4.1.11.2.29.2.0.40300003 | current |
| hHPOC_40300006 NOTIFICATION-TYPE Required <string> Id=<number> not found in network configuration | 1.3.6.1.4.1.11.2.29.2.0.40300006 | current |
| hHPOC_40400001 NOTIFICATION-TYPE The maximum licensed traffic capacity of <string> is exceeded. | 1.3.6.1.4.1.11.2.29.2.0.40400001 | current |
| hHPOC_40400002 NOTIFICATION-TYPE The traffic of <string> is about to reach the maximum licensed traffic capacity of <string>. | 1.3.6.1.4.1.11.2.29.2.0.40400002 | current |
| hHPOC_40400003 NOTIFICATION-TYPE The Traffic of <string> is now back below the maximum licensed traffic capacity. | 1.3.6.1.4.1.11.2.29.2.0.40400003 | current |
| hHPOC_40300011 NOTIFICATION-TYPE Error while accessing configuration file | 1.3.6.1.4.1.11.2.29.2.0.403000011 | current |
| hHPOC_40300015 NOTIFICATION-TYPE Missing or invalid Primary address in Static Configuration file | 1.3.6.1.4.1.11.2.29.2.0.403000015 | current |
| hHPOC_40300016 NOTIFICATION-TYPE Failed to retrieve statistics from M3UA stack | 1.3.6.1.4.1.11.2.29.2.0.403000016 | current |
| hHPOC_40300017 NOTIFICATION-TYPE Automatic loadconf failed on M3UA instance <number>, SHUTTING DOWN | 1.3.6.1.4.1.11.2.29.2.0.403000017 | current |