MIBs Depot

HP-ICF-TRANSCEIVER-MIB

Registered at
1.3.6.1.4.1.11.2.14.11.5.1.82
Last updated
2011-07-25 00:00
Organization
HP Networking
Revisions
2011-07-25 00:00, 2011-06-08 00:00, 2011-03-14 00:00, 2011-03-02 00:00
Namespace
hp
Source file
HP-ICF-TRANSCEIVER-MIB
Digest
sha256:aa7d99aa0f14e72b069d7cf660260b68635c7a712a81f0dcc1b1d63f1eb2a1c3

Description

This MIB module describes HP transceiver information.

Contact

Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747

Imports

FromSymbols
HP-ICF-OIDhpSwitch
IF-MIBifIndex
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HP-ICF-OID
HP-ICF-TRANSCEIVER-MIB
IANAifType-MIB
IF-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hpicfXcvrObjects
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.82.1
hpicfXcvrInfo
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1
hpicfXcvrInfoTable
OBJECT-TYPE
A table of objects that display transceiver characteristics.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1not-accessiblecurrent
hpicfXcvrInfoEntry
OBJECT-TYPE
A set of objects that displays information of a transceiver.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1not-accessiblecurrent
hpicfXcvrPortIndex
OBJECT-TYPE
The interface number for this entry.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.1Integer32 (1..2147483647)read-onlycurrent
hpicfXcvrPortDesc
OBJECT-TYPE
A textual description of the interface.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.2SnmpAdminString (SIZE(1..8))read-onlycurrent
hpicfXcvrModel
OBJECT-TYPE
A textual description of the transceiver model number.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.3SnmpAdminString (SIZE(1..32))read-onlycurrent
hpicfXcvrSerial
OBJECT-TYPE
A textual description of the transceiver serial number.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.4SnmpAdminString (SIZE(1..32))read-onlycurrent
hpicfXcvrType
OBJECT-TYPE
A textual description of the transceiver type.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.5SnmpAdminString (SIZE(1..32))read-onlycurrent
hpicfXcvrConnectorType
OBJECT-TYPE
A textual description of the transceiver connector type.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.6SnmpAdminString (SIZE(1..64))read-onlycurrent
hpicfXcvrWavelength
OBJECT-TYPE
A textual description of the central optical wavelength. n/a will be reported for copper transceivers.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.7SnmpAdminString (SIZE(1..96))read-onlycurrent
hpicfXcvrTxDist
OBJECT-TYPE
A textual description of the link length supported by the transceiver.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.8SnmpAdminString (SIZE(1..64))read-onlycurrent
hpicfXcvrDiagnostics
OBJECT-TYPE
This object indicates transceiver diagnostic support. May be one of Virtual Cable Test (VCT), Diagnostic Optical Monitoring (DOM), other or none.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.9INTEGER {none(0), dom(1), vct(2), other(3)}read-onlycurrent
hpicfXcvrDiagnosticsUpdate
OBJECT-TYPE
This object will cause specific actions depending on the diagnostic support of the transceiver. Transceiver Diagnostic support: None : No action taken. DOM : Will update diagnostic information for the transceiver. VCT : Will update diagnostic information for the transceiver. Other : Vendor specific. The value of the object will be reset after the completion of the update. Please note: VCT and other (cable-diagnostics) may cause a loss of link and take a few second to run for each interface.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.10TruthValueread-writecurrent
hpicfXcvrTemp
OBJECT-TYPE
This is transceiver internal temperature in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11Integer32read-onlycurrent
hpicfXcvrVoltage
OBJECT-TYPE
This is transceiver supply voltage in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Will be zero if the transceiver does not report this object. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrBias
OBJECT-TYPE
This is Tx bias current in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrTxPower
OBJECT-TYPE
This is transmit output power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14Integer32read-onlycurrent
hpicfXcvrRxPower
OBJECT-TYPE
This is received optical power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15Integer32read-onlycurrent
hpicfXcvrAlarms
OBJECT-TYPE
Bitmask indicating transceiver alarms, Rx power low warning(0) Rx power high warning(1) Tx power low warning(2) Tx power high warning(3) Tx bias low warning(4) Tx bias high warning(5) Vcc low warning(6) Vcc high warning(7) Temp low warning(8) Temp high warning(9) Rx power low alarm(10) Rx power high alarm(11) Tx power low alarm(12) Tx power high alarm(13) Tx bias low alarm(14) Tx bias high alarm(15) Vcc low alarm(16) Vcc high alarm(17) Temp low alarm(18) Temp high alarm(19) Unused(20-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.16Bits {rxPowerLowWarning(0), rxPowerHighWarning(1), txPowerLowWarning(2), txPowerHighWarning(3), txBiasLowWarning(4), txBiasHighWarning(5), vccLowWarning(6), vccHighWarning(7), tempLowWarning(8), tempHighWarning(9), rxPowerLowAlarm(10), rxPowerHighAlarm(11), txPowerLowAlarm(12), txPowerHighAlarm(13), txBiasLowAlarm(14), txBiasHighAlarm(15), vccLowAlarm(16), vccHighAlarm(17), tempLowAlarm(18), tempHighAlarm(19)}read-onlycurrent
hpicfXcvrErrors
OBJECT-TYPE
Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.17Bits {xcvrIOError(0), xcvrChecksum(1), xcvrTypeAndPortConfigMismatch(2), xcvrTypeNotSupported(3), wisLocalFault(4), rcvOpticalPowerFault(5), pmapmdReceiverLocalFault(6), pcsReceiveLocalFault(7), phyXSReceiveLocalFault(8), laserBiasCurrentFault(9), laserTemperatureFault(10), laserOutputPowerFault(11), txFault(12), pmapmdTransmitterLocalFault(13), pcsTransmitLocalFault(14), phyXSTransmitLocalFault(15), rxLossOfSignal(16)}read-onlycurrent
hpicfXcvrTempHiAlarm
OBJECT-TYPE
Transceiver temperature high alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.18Integer32read-onlycurrent
hpicfXcvrTempLoAlarm
OBJECT-TYPE
Transceiver temperature low alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.19Integer32read-onlycurrent
hpicfXcvrTempHiWarn
OBJECT-TYPE
Transceiver temperature high warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.20Integer32read-onlycurrent
hpicfXcvrTempLoWarn
OBJECT-TYPE
Transceiver temperature low warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.21Integer32read-onlycurrent
hpicfXcvrVccHiAlarm
OBJECT-TYPE
Transceiver VCC high alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.22Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrVccLoAlarm
OBJECT-TYPE
Transceiver VCC low alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.23Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrVccHiWarn
OBJECT-TYPE
Transceiver VCC high warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.24Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrVccLoWarn
OBJECT-TYPE
Transceiver VCC low warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.25Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrBiasHiAlarm
OBJECT-TYPE
Transceiver bias high alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.26Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrBiasLoAlarm
OBJECT-TYPE
Transceiver bias low alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.27Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrBiasHiWarn
OBJECT-TYPE
Transceiver bias high warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.28Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrBiasLoWarn
OBJECT-TYPE
Transceiver bias low warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.29Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrPwrOutHiAlarm
OBJECT-TYPE
Transceiver transmit power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.30Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrPwrOutLoAlarm
OBJECT-TYPE
Transceiver transmit power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.31Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrPwrOutHiWarn
OBJECT-TYPE
Transceiver transmit power high warning threshold limit in tenths of microwatts As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.32Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrPwrOutLoWarn
OBJECT-TYPE
Transceiver transmit power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.33Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrRcvPwrHiAlarm
OBJECT-TYPE
Transceiver receive power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.34Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrRcvPwrLoAlarm
OBJECT-TYPE
Transceiver receive power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.35Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrRcvPwrHiWarn
OBJECT-TYPE
Transceiver receive power high warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.36Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrRcvPwrLoWarn
OBJECT-TYPE
Transceiver receive power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.37Unsigned32 (0..65535)read-onlycurrent
hpicfXcvrDiagnosticsTimeStamp
OBJECT-TYPE
********* THIS OBJECT IS DEPRECATED ********* A textual description of the diagnostics information updated for the last time in the transceiver. This object has been deprecated. Its functionality has been replaced by hpicfXcvrDiagnosticsTimeticks.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.38SnmpAdminString (SIZE(1..64))read-onlydeprecated
hpicfXcvrPhyLinkStatus
OBJECT-TYPE
This object indicates the link status as reported by the physical entity. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.39INTEGER {down(0), up(1)}read-onlycurrent
hpicfXcvrPhySpeed
OBJECT-TYPE
This object indicates the speed in Mbps as reported by the physical entity. Will be zero if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.40Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrPhyDuplex
OBJECT-TYPE
This object indicates the duplex as reported by the physical entity. Will be unspecified if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.41INTEGER {half(0), full(1), unspecified(2)}read-onlycurrent
hpicfXcvrMdiPairACableStatus
OBJECT-TYPE
This object indicates the diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.42INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)}read-onlycurrent
hpicfXcvrMdiPairACableLength
OBJECT-TYPE
This object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.43Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairADistanceToFault
OBJECT-TYPE
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.44Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairAPolaritySwap
OBJECT-TYPE
This object indicates if the cable pair connected to the phy is inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.45INTEGER {normal(0), reversed(1), unspecified(2)}read-onlycurrent
hpicfXcvrMdiPairASkew
OBJECT-TYPE
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.46Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairBCableStatus
OBJECT-TYPE
This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.47INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)}read-onlycurrent
hpicfXcvrMdiPairBCableLength
OBJECT-TYPE
This object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.48Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairBDistanceToFault
OBJECT-TYPE
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.49Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairBPolaritySwap
OBJECT-TYPE
This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.50INTEGER {normal(0), reversed(1), unspecified(2)}read-onlycurrent
hpicfXcvrMdiPairBSkew
OBJECT-TYPE
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.51Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairCCableStatus
OBJECT-TYPE
This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)}read-onlycurrent
hpicfXcvrMdiPairCCableLength
OBJECT-TYPE
This object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.53Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairCDistanceToFault
OBJECT-TYPE
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if there is no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.54Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairCPolaritySwap
OBJECT-TYPE
This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.55INTEGER {normal(0), reversed(1), unspecified(2)}read-onlycurrent
hpicfXcvrMdiPairCSkew
OBJECT-TYPE
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.56Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairDCableStatus
OBJECT-TYPE
This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.57INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)}read-onlycurrent
hpicfXcvrMdiPairDCableLength
OBJECT-TYPE
This object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.58Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairDDistanceToFault
OBJECT-TYPE
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.59Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairDPolaritySwap
OBJECT-TYPE
This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.60INTEGER {normal(0), reversed(1), unspecified(2)}read-onlycurrent
hpicfXcvrMdiPairDSkew
OBJECT-TYPE
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.61Unsigned32 (0..4294967295)read-onlycurrent
hpicfXcvrMdiPairABSwap
OBJECT-TYPE
This object indicates the if the channels are swapped for channels A and B as reported through cable diagnostics. MDI : Channel A received on MDI[1], Channel B on MDI[0] MDIX : Channel A received on MDI[0], Channel B on MDI[1] Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.62INTEGER {mdi(0), mdix(1), unspecified(2)}read-onlycurrent
hpicfXcvrMdiPairCDSwap
OBJECT-TYPE
This object indicates if the channels are swapped for channels C and D as reported through cable diagnostics. MDI : Channel C received on MDI[3], Channel D on MDI[2] MDIX : Channel C received on MDI[2], Channel D on MDI[3]. Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.63INTEGER {mdi(0), mdix(1), unspecified(2)}read-onlycurrent
hpicfXcvrDiagnosticsTimeTicks
OBJECT-TYPE
The value of sysUpTime of when this diagnostic information was last updated. If this diagnostic information was never updated, then this object will contain a zero value.
1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.64TimeTicksread-onlycurrent
hpicfXcvrConformance
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.82.2
hpicfXcvrGroups
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.82.2.1
hpicfXcvrCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.82.2.2

Conformance

NameOIDStatus
hpicfXcvrInfoGroup
OBJECT-GROUP
********* THIS GROUP IS DEPRECATED ********* A collection of objects representing transceiver information. This object has been deprecated and replaced with hpicfXcvrInfoGroup1.
1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.1deprecated
hpicfXcvrInfoGroup1
OBJECT-GROUP
A collection of objects representing transceiver information.
1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.2current
hpicfXcvrCompliance
MODULE-COMPLIANCE
********* THIS COMPLIANCE IS DEPRECATED ********* Describes the requirements for conformance to the transceiver MIB. This compliance section has been deprecated and replaced with hpicfXcvrCompliance1.
1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.1deprecated
hpicfXcvrCompliance1
MODULE-COMPLIANCE
Describes the requirements for conformance to the transceiver MIB.
1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.2current