HP-ICF-TRANSCEIVER-MIB
- Registered at
- 1.3.6.1.4.1.11.2.14.11.5.1.82
- Last updated
- 2011-07-25 00:00
- Organization
- HP Networking
- Revisions
- 2011-07-25 00:00, 2011-06-08 00:00, 2011-03-14 00:00, 2011-03-02 00:00
- Namespace
- hp
- Source file
HP-ICF-TRANSCEIVER-MIB- Digest
sha256:aa7d99aa0f14e72b069d7cf660260b68635c7a712a81f0dcc1b1d63f1eb2a1c3
Description
This MIB module describes HP transceiver information.
Contact
Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747
Imports
| From | Symbols |
|---|---|
| HP-ICF-OID | hpSwitch |
| IF-MIB | ifIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HP-ICF-OID HP-ICF-TRANSCEIVER-MIB IANAifType-MIB IF-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hpicfXcvrObjects OBJECT-IDENTITY | 1.3.6.1.4.1.11.2.14.11.5.1.82.1 | |||
| hpicfXcvrInfo OBJECT-IDENTITY | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1 | |||
| hpicfXcvrInfoTable OBJECT-TYPE A table of objects that display transceiver characteristics. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1 | not-accessible | current | |
| hpicfXcvrInfoEntry OBJECT-TYPE A set of objects that displays information of a transceiver. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1 | not-accessible | current | |
| hpicfXcvrPortIndex OBJECT-TYPE The interface number for this entry. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.1 | Integer32 (1..2147483647) | read-only | current |
| hpicfXcvrPortDesc OBJECT-TYPE A textual description of the interface. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.2 | SnmpAdminString (SIZE(1..8)) | read-only | current |
| hpicfXcvrModel OBJECT-TYPE A textual description of the transceiver model number. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.3 | SnmpAdminString (SIZE(1..32)) | read-only | current |
| hpicfXcvrSerial OBJECT-TYPE A textual description of the transceiver serial number. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.4 | SnmpAdminString (SIZE(1..32)) | read-only | current |
| hpicfXcvrType OBJECT-TYPE A textual description of the transceiver type. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.5 | SnmpAdminString (SIZE(1..32)) | read-only | current |
| hpicfXcvrConnectorType OBJECT-TYPE A textual description of the transceiver connector type. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.6 | SnmpAdminString (SIZE(1..64)) | read-only | current |
| hpicfXcvrWavelength OBJECT-TYPE A textual description of the central optical wavelength. n/a will be reported for copper transceivers. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.7 | SnmpAdminString (SIZE(1..96)) | read-only | current |
| hpicfXcvrTxDist OBJECT-TYPE A textual description of the link length supported by the transceiver. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.8 | SnmpAdminString (SIZE(1..64)) | read-only | current |
| hpicfXcvrDiagnostics OBJECT-TYPE This object indicates transceiver diagnostic support. May be one of Virtual Cable Test (VCT), Diagnostic Optical Monitoring (DOM), other or none. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.9 | INTEGER {none(0), dom(1), vct(2), other(3)} | read-only | current |
| hpicfXcvrDiagnosticsUpdate OBJECT-TYPE This object will cause specific actions depending on the diagnostic support of the transceiver. Transceiver Diagnostic support: None : No action taken. DOM : Will update diagnostic information for the transceiver. VCT : Will update diagnostic information for the transceiver. Other : Vendor specific. The value of the object will be reset after the completion of the update. Please note: VCT and other (cable-diagnostics) may cause a loss of link and take a few second to run for each interface. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.10 | TruthValue | read-write | current |
| hpicfXcvrTemp OBJECT-TYPE This is transceiver internal temperature in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11 | Integer32 | read-only | current |
| hpicfXcvrVoltage OBJECT-TYPE This is transceiver supply voltage in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Will be zero if the transceiver does not report this object. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrBias OBJECT-TYPE This is Tx bias current in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrTxPower OBJECT-TYPE This is transmit output power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14 | Integer32 | read-only | current |
| hpicfXcvrRxPower OBJECT-TYPE This is received optical power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15 | Integer32 | read-only | current |
| hpicfXcvrAlarms OBJECT-TYPE Bitmask indicating transceiver alarms, Rx power low warning(0) Rx power high warning(1) Tx power low warning(2) Tx power high warning(3) Tx bias low warning(4) Tx bias high warning(5) Vcc low warning(6) Vcc high warning(7) Temp low warning(8) Temp high warning(9) Rx power low alarm(10) Rx power high alarm(11) Tx power low alarm(12) Tx power high alarm(13) Tx bias low alarm(14) Tx bias high alarm(15) Vcc low alarm(16) Vcc high alarm(17) Temp low alarm(18) Temp high alarm(19) Unused(20-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.16 | Bits {rxPowerLowWarning(0), rxPowerHighWarning(1), txPowerLowWarning(2), txPowerHighWarning(3), txBiasLowWarning(4), txBiasHighWarning(5), vccLowWarning(6), vccHighWarning(7), tempLowWarning(8), tempHighWarning(9), rxPowerLowAlarm(10), rxPowerHighAlarm(11), txPowerLowAlarm(12), txPowerHighAlarm(13), txBiasLowAlarm(14), txBiasHighAlarm(15), vccLowAlarm(16), vccHighAlarm(17), tempLowAlarm(18), tempHighAlarm(19)} | read-only | current |
| hpicfXcvrErrors OBJECT-TYPE Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.17 | Bits {xcvrIOError(0), xcvrChecksum(1), xcvrTypeAndPortConfigMismatch(2), xcvrTypeNotSupported(3), wisLocalFault(4), rcvOpticalPowerFault(5), pmapmdReceiverLocalFault(6), pcsReceiveLocalFault(7), phyXSReceiveLocalFault(8), laserBiasCurrentFault(9), laserTemperatureFault(10), laserOutputPowerFault(11), txFault(12), pmapmdTransmitterLocalFault(13), pcsTransmitLocalFault(14), phyXSTransmitLocalFault(15), rxLossOfSignal(16)} | read-only | current |
| hpicfXcvrTempHiAlarm OBJECT-TYPE Transceiver temperature high alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.18 | Integer32 | read-only | current |
| hpicfXcvrTempLoAlarm OBJECT-TYPE Transceiver temperature low alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.19 | Integer32 | read-only | current |
| hpicfXcvrTempHiWarn OBJECT-TYPE Transceiver temperature high warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.20 | Integer32 | read-only | current |
| hpicfXcvrTempLoWarn OBJECT-TYPE Transceiver temperature low warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.21 | Integer32 | read-only | current |
| hpicfXcvrVccHiAlarm OBJECT-TYPE Transceiver VCC high alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.22 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrVccLoAlarm OBJECT-TYPE Transceiver VCC low alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.23 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrVccHiWarn OBJECT-TYPE Transceiver VCC high warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.24 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrVccLoWarn OBJECT-TYPE Transceiver VCC low warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.25 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrBiasHiAlarm OBJECT-TYPE Transceiver bias high alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.26 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrBiasLoAlarm OBJECT-TYPE Transceiver bias low alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.27 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrBiasHiWarn OBJECT-TYPE Transceiver bias high warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.28 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrBiasLoWarn OBJECT-TYPE Transceiver bias low warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.29 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrPwrOutHiAlarm OBJECT-TYPE Transceiver transmit power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.30 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrPwrOutLoAlarm OBJECT-TYPE Transceiver transmit power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.31 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrPwrOutHiWarn OBJECT-TYPE Transceiver transmit power high warning threshold limit in tenths of microwatts As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.32 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrPwrOutLoWarn OBJECT-TYPE Transceiver transmit power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.33 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrRcvPwrHiAlarm OBJECT-TYPE Transceiver receive power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.34 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrRcvPwrLoAlarm OBJECT-TYPE Transceiver receive power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.35 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrRcvPwrHiWarn OBJECT-TYPE Transceiver receive power high warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.36 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrRcvPwrLoWarn OBJECT-TYPE Transceiver receive power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.37 | Unsigned32 (0..65535) | read-only | current |
| hpicfXcvrDiagnosticsTimeStamp OBJECT-TYPE ********* THIS OBJECT IS DEPRECATED ********* A textual description of the diagnostics information updated for the last time in the transceiver. This object has been deprecated. Its functionality has been replaced by hpicfXcvrDiagnosticsTimeticks. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.38 | SnmpAdminString (SIZE(1..64)) | read-only | deprecated |
| hpicfXcvrPhyLinkStatus OBJECT-TYPE This object indicates the link status as reported by the physical entity. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.39 | INTEGER {down(0), up(1)} | read-only | current |
| hpicfXcvrPhySpeed OBJECT-TYPE This object indicates the speed in Mbps as reported by the physical entity. Will be zero if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.40 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrPhyDuplex OBJECT-TYPE This object indicates the duplex as reported by the physical entity. Will be unspecified if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.41 | INTEGER {half(0), full(1), unspecified(2)} | read-only | current |
| hpicfXcvrMdiPairACableStatus OBJECT-TYPE This object indicates the diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.42 | INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)} | read-only | current |
| hpicfXcvrMdiPairACableLength OBJECT-TYPE This object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.43 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairADistanceToFault OBJECT-TYPE This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.44 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairAPolaritySwap OBJECT-TYPE This object indicates if the cable pair connected to the phy is inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.45 | INTEGER {normal(0), reversed(1), unspecified(2)} | read-only | current |
| hpicfXcvrMdiPairASkew OBJECT-TYPE This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.46 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairBCableStatus OBJECT-TYPE This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.47 | INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)} | read-only | current |
| hpicfXcvrMdiPairBCableLength OBJECT-TYPE This object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.48 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairBDistanceToFault OBJECT-TYPE This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.49 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairBPolaritySwap OBJECT-TYPE This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.50 | INTEGER {normal(0), reversed(1), unspecified(2)} | read-only | current |
| hpicfXcvrMdiPairBSkew OBJECT-TYPE This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.51 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairCCableStatus OBJECT-TYPE This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52 | INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)} | read-only | current |
| hpicfXcvrMdiPairCCableLength OBJECT-TYPE This object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.53 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairCDistanceToFault OBJECT-TYPE This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if there is no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.54 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairCPolaritySwap OBJECT-TYPE This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.55 | INTEGER {normal(0), reversed(1), unspecified(2)} | read-only | current |
| hpicfXcvrMdiPairCSkew OBJECT-TYPE This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.56 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairDCableStatus OBJECT-TYPE This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.57 | INTEGER {normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)} | read-only | current |
| hpicfXcvrMdiPairDCableLength OBJECT-TYPE This object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.58 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairDDistanceToFault OBJECT-TYPE This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.59 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairDPolaritySwap OBJECT-TYPE This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.60 | INTEGER {normal(0), reversed(1), unspecified(2)} | read-only | current |
| hpicfXcvrMdiPairDSkew OBJECT-TYPE This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.61 | Unsigned32 (0..4294967295) | read-only | current |
| hpicfXcvrMdiPairABSwap OBJECT-TYPE This object indicates the if the channels are swapped for channels A and B as reported through cable diagnostics. MDI : Channel A received on MDI[1], Channel B on MDI[0] MDIX : Channel A received on MDI[0], Channel B on MDI[1] Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.62 | INTEGER {mdi(0), mdix(1), unspecified(2)} | read-only | current |
| hpicfXcvrMdiPairCDSwap OBJECT-TYPE This object indicates if the channels are swapped for channels C and D as reported through cable diagnostics. MDI : Channel C received on MDI[3], Channel D on MDI[2] MDIX : Channel C received on MDI[2], Channel D on MDI[3]. Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.63 | INTEGER {mdi(0), mdix(1), unspecified(2)} | read-only | current |
| hpicfXcvrDiagnosticsTimeTicks OBJECT-TYPE The value of sysUpTime of when this diagnostic information was last updated. If this diagnostic information was never updated, then this object will contain a zero value. | 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.64 | TimeTicks | read-only | current |
| hpicfXcvrConformance OBJECT-IDENTITY | 1.3.6.1.4.1.11.2.14.11.5.1.82.2 | |||
| hpicfXcvrGroups OBJECT-IDENTITY | 1.3.6.1.4.1.11.2.14.11.5.1.82.2.1 | |||
| hpicfXcvrCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.11.2.14.11.5.1.82.2.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| hpicfXcvrInfoGroup OBJECT-GROUP ********* THIS GROUP IS DEPRECATED ********* A collection of objects representing transceiver information. This object has been deprecated and replaced with hpicfXcvrInfoGroup1. | 1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.1 | deprecated |
| hpicfXcvrInfoGroup1 OBJECT-GROUP A collection of objects representing transceiver information. | 1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.2 | current |
| hpicfXcvrCompliance MODULE-COMPLIANCE ********* THIS COMPLIANCE IS DEPRECATED ********* Describes the requirements for conformance to the transceiver MIB. This compliance section has been deprecated and replaced with hpicfXcvrCompliance1. | 1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.1 | deprecated |
| hpicfXcvrCompliance1 MODULE-COMPLIANCE Describes the requirements for conformance to the transceiver MIB. | 1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.2 | current |