MIBs Depot

HP-ICF-INST-MIB

Registered at
1.3.6.1.4.1.11.2.14.11.5.1.45
Last updated
2007-09-07 00:00
Organization
HP Networking
Revisions
2007-09-07 00:00
Namespace
hp
Source file
HP-ICF-INST-MIB
Digest
sha256:5f038fe6b2047725902a0eb21e572109633884343144d7bc45c1c8dcf2633f8f

Description

This MIB module contains HP proprietary definitions for Instrumentation.

Contact

Hewlett-Packard Company 8000 Foothills Blvd. Roseville, CA 95747

Imports

FromSymbols
HP-ICF-OIDhpSwitch
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HP-ICF-INST-MIB
HP-ICF-OID
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
hpicfInstObjects
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.45.1
hpicfInstEnable
OBJECT-TYPE
The operational status of Instrumentation on this switch.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.1TruthValueread-onlycurrent
hpicfInstMaxMemMB
OBJECT-TYPE
The maximum memory that can be used by Instrumentation, in megabytes.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.2Integer32read-writecurrent
hpicfInstParameterTable
OBJECT-TYPE
Values of monitored instrumentation parameters.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3not-accessiblecurrent
hpicfInstParameterEntry
OBJECT-TYPE
An entry in the hpicfInstParameterTable.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1not-accessiblecurrent
hpicfInstParameterIndex
OBJECT-TYPE
The index of the parameter.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.1Integer32 (1..65535)not-accessiblecurrent
hpicfInstInterfaceIndex
OBJECT-TYPE
Interface index i.e. port number for per port parameters and 0 for global parameters.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.2Integer32 (1..65535)not-accessiblecurrent
hpicfInstIntervalIndex
OBJECT-TYPE
The index of the interval.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.3Integer32 (1..65535)not-accessiblecurrent
hpicfInstParameterName
OBJECT-TYPE
The name of the parameter.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.4DisplayString (SIZE(0..20))read-onlycurrent
hpicfInstIntervalName
OBJECT-TYPE
The name of the interval.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.5DisplayString (SIZE(0..20))read-onlycurrent
hpicfInstParameterValue
OBJECT-TYPE
The current parameter value for the given interface and interval.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.6Unsigned32read-onlycurrent
hpicfInstParamValMin
OBJECT-TYPE
The minimum value of the parameter for the given interface and interval.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.7Unsigned32read-onlycurrent
hpicfInstParamValMax
OBJECT-TYPE
The maximum value of the parameter for the given interface and interval.
1.3.6.1.4.1.11.2.14.11.5.1.45.1.3.1.8Unsigned32read-onlycurrent
hpicfInstConformance
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.45.2
hpicfInstGroups
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.45.2.1
hpicfInstCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.11.2.14.11.5.1.45.2.2

Conformance

NameOIDStatus
hpicfInstBaseGroup
OBJECT-GROUP
A collection of objects to support basic Instrumentation configuration on HP switches.
1.3.6.1.4.1.11.2.14.11.5.1.45.2.1.2current
hpicfInstBaseCompliance
MODULE-COMPLIANCE
The compliance statement for HP switches running Instrumentation and implementing the HP-ICF-INST MIB.
1.3.6.1.4.1.11.2.14.11.5.1.45.2.2.1current