HILLSTONE-SYSTEM-MIB
- Registered at
- 1.3.6.1.4.1.28557.2.2.1
- Namespace
- hillstone
- Source file
HILLSTONE-SYSTEM-MIB- Digest
sha256:1b071ecd764bef40a19b1191d7f4233a180a4e5d57b447f7a3b8349555cbbc77
Imports
| From | Symbols |
|---|---|
| HILLSTONE-SMI | hillstoneSys |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HILLSTONE-SMI HILLSTONE-SYSTEM-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| DisplayString type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hillstoneSysMibObjects OBJECT-IDENTITY | 1.3.6.1.4.1.28557.2.2.1 | |||
| sysSerialNumber OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.1 | DisplayString | read-only | mandatory |
| sysSoftware OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.2 | DisplayString | read-only | mandatory |
| sysCPU OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.3 | INTEGER | read-only | mandatory |
| sysTotalMemory OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.4 | Gauge32 | read-only | mandatory |
| sysCurMemory OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.5 | Gauge32 | read-only | mandatory |
| sysTotalSession OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.6 | Counter | read-only | mandatory |
| sysCurSession OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.7 | Gauge32 | read-only | mandatory |
| sysHAStatus OBJECT-TYPE | 1.3.6.1.4.1.28557.2.2.1.8 | INTEGER {none(0), init(1), hello(2), backup(3), master(4), slase(5), AA-mode(6)} | read-only | mandatory |
| sysSnmpStackStatus OBJECT-TYPE The running status of snmp Stack. | 1.3.6.1.4.1.28557.2.2.1.9 | TruthValue | read-only | current |
| sysTr069StackStatus OBJECT-TYPE The running status of tr069 stack. | 1.3.6.1.4.1.28557.2.2.1.10 | TruthValue | read-only | current |
| sysVedorOUI OBJECT-TYPE The oui code of the Tr069 stack.. | 1.3.6.1.4.1.28557.2.2.1.11 | DisplayString | read-only | current |
| sysLogStackStatus OBJECT-TYPE The running status of syslog stack. | 1.3.6.1.4.1.28557.2.2.1.12 | TruthValue | read-only | current |
| sysLogServerAddress1 OBJECT-TYPE The syslog receiver addrees 1. | 1.3.6.1.4.1.28557.2.2.1.13 | DisplayString | read-only | current |
| sysLogServerAddress2 OBJECT-TYPE The syslog receiver addrees 2. | 1.3.6.1.4.1.28557.2.2.1.14 | DisplayString | read-only | current |
| sysDeviceReloadAction OBJECT-TYPE The actioin of reloading the device. when the value is set to 2,the device will reboot at once. | 1.3.6.1.4.1.28557.2.2.1.15 | INTEGER {reloadUnAvailable(1), reloadAtOnce(2)} | read-only | current |
| sysStatisticsPeriod OBJECT-TYPE The period of statistics. default statistics period is 24hours | 1.3.6.1.4.1.28557.2.2.1.16 | INTEGER {oneDay(1)} | read-only | current |