HH3C-VSAN-MIB
- Registered at
- 1.3.6.1.4.1.25506.2.127
- Last updated
- 2014-07-25 18:40
- Organization
- New H3C Tech. Co., Ltd.
- Revisions
- 2014-07-25 18:40, 2014-05-09 18:40, 2014-03-04 15:50, 2013-02-28 09:40
- Namespace
- comware
- Source file
HH3C-VSAN-MIB- Digest
sha256:944cca31632d1dce30f42c91525ed7db54dbad2b9bfc8a4c5517eaea81f248bb
Description
This MIB module is for configuring and monitoring VSAN and domain management related entities.
Contact
Platform Team New H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085
Imports
| From | Symbols |
|---|---|
| HH3C-FC-TC-MIB | Hh3cFcAddressId, Hh3cFcDmState, Hh3cFcDomainId, Hh3cFcDomainIdList, Hh3cFcDomainIdOrZero, Hh3cFcDomainPriority, Hh3cFcNameId, Hh3cFcNameIdOrZero, Hh3cFcVsanIndex |
| HH3C-OID-MIB | hh3cCommon |
| IF-MIB | ifIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
9 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HH3C-FC-TC-MIB HH3C-OID-MIB HH3C-VSAN-MIB IANAifType-MIB IF-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25506.2.127.2 | hh3cSanAgg | HH3C-SAN-AGG-MIB |
| 1.3.6.1.4.1.25506.2.127.3 | hh3cFcFLogin | HH3C-FC-FLOGIN-MIB |
| 1.3.6.1.4.1.25506.2.127.4 | hh3cFcTraceRoute | HH3C-FC-TRACE-ROUTE-MIB |
| 1.3.6.1.4.1.25506.2.127.5 | hh3cFcPing | HH3C-FC-PING-MIB |
| 1.3.6.1.4.1.25506.2.127.6 | hh3cNpv | HH3C-NPV-MIB |
| 1.3.6.1.4.1.25506.2.127.7 | hh3cFdmi | HH3C-FDMI-MIB |
| 1.3.6.1.4.1.25506.2.127.8 | hh3cFcPsm | HH3C-FC-PSM-MIB |
| 1.3.6.1.4.1.25506.2.127.9 | hh3cFcZoneServer | HH3C-FC-ZONE-SERVER-MIB |
| 1.3.6.1.4.1.25506.2.127.10 | hh3cFcNameServer | HH3C-FC-NAME-SERVER-MIB |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hh3cVsan OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1 | |||
| hh3cVsanMibObjects OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1.1 | |||
| hh3cVsanDmConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1.1.1 | |||
| hh3cVsanTable OBJECT-TYPE A table contains all the VSANs configured on the device. It can be used to manage and monitor the VSANs on local device. | 1.3.6.1.4.1.25506.2.127.1.1.1.1 | not-accessible | current | |
| hh3cVsanEntry OBJECT-TYPE An entry that contains information about a VSAN in the hh3cVsanTable. | 1.3.6.1.4.1.25506.2.127.1.1.1.1.1 | not-accessible | current | |
| hh3cVsanIndex OBJECT-TYPE The identifier of the VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.1.1.1 | Hh3cFcVsanIndex | accessible-for-notify | current |
| hh3cVsanCoreSwitchName OBJECT-TYPE The Core Switch_Name of the VSAN, which is indicated by the switch's WWN(World Wide Name). | 1.3.6.1.4.1.25506.2.127.1.1.1.1.1.2 | Hh3cFcNameIdOrZero (SIZE(8 | 16)) | read-only | current |
| hh3cVsanRowStatus OBJECT-TYPE RowStatus. Now only three states are supported: createAndGo, active, and destroy. | 1.3.6.1.4.1.25506.2.127.1.1.1.1.1.3 | RowStatus | read-create | current |
| hh3cVsanName OBJECT-TYPE The name of the VSAN. The default value of this object will be the string 'VSANxxxx' where xxxx is value of VSAN index expressed as 4 digits. For example, if VSAN index is 10, the default value of this object is 'VSAN0010'. | 1.3.6.1.4.1.25506.2.127.1.1.1.1.1.4 | SnmpAdminString (SIZE(0..32)) | read-create | current |
| hh3cVsanWorkingMode OBJECT-TYPE This object specifies the working modes the VSAN supports. The object has three available values: 1: non-FCoE mode. 2: FCF mode. 3: NPV mode. The working mode of VSAN 4079 is always non-FCoE mode and cannot be converted. If the switch mode is not FCF-NPV mode, then the 'SET' operation on this object results in error. When creating a VSAN, the 'SET' operation including this object results in error. When the switch mode is FCF mode, working modes of all user VSANs are FCF mode. When the switch mode is NPV mode, working modes of all user VSANs are NPV mode. When the switch mode is FCF-NPV mode, the default working mode of a user VSAN is NPV mode. If a VSAN has been created, the working mode can be converted from NPV mode to FCF mode, or vice versa. | 1.3.6.1.4.1.25506.2.127.1.1.1.1.1.5 | Integer32 | read-create | current |
| hh3cVsanDmTable OBJECT-TYPE A table contains domain management related configurations and information of VSANs. An entry in this table is created when corresponding VSAN is created, as well as deleted when the VSAN is deleted. | 1.3.6.1.4.1.25506.2.127.1.1.1.2 | not-accessible | current | |
| hh3cVsanDmEntry OBJECT-TYPE An entry of domain management related configurations and information of a specified VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1 | not-accessible | current | |
| hh3cVsanDmDomainConfigureEnable OBJECT-TYPE To enable or disable the fabric configuration function in this VSAN. true: enabled, the fabric will be built dynamically. false: disabled, the fabric should be built statically by manual configurations. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.1 | TruthValue | read-write | current |
| hh3cVsanDmFabricNameConfigured OBJECT-TYPE Specifies the fabric name in this VSAN, and will use a zero-length octet string as default value if not configured. The fabric name specified here takes effect only if the value of hh3cVsanDmDomainConfigureEnable is 'false', and the same fabric name should be configured for all switches in this VSAN. If the value of hh3cVsanDmDomainConfigureEnable is 'true', the principal switch WWN is used as fabric name. The value should be set to zero-length when canceling a configured fabric name. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.2 | Hh3cFcNameIdOrZero | read-write | current |
| hh3cVsanDmPriorityConfigured OBJECT-TYPE Specifies the priority of a switch in this VSAN, which is used during principal switch selection to cause one Switch to be favored over another. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.3 | Hh3cFcDomainPriority | read-write | current |
| hh3cVsanDmAllowedDomainIdList OBJECT-TYPE Specifies the list of domain IDs that are allowed in the VSAN, and the configuration has different meanings in different scenarios: 1. Principal switch: Can only assign domains IDs within the allowed domain ID list. If the allowed domain ID list configured does not include any of the already assigned domain IDs or manually configured domain IDs, the configuration will fail. 2. Non-principal switch: The manually configured domain ID must be within the allowed domain ID list, or the configuration will fail. Besides, the domain ID assigned by principal switch must within the allowed domain ID list, or the switch will refuse the assigned domain ID and isolate the upstream interface. If the runtime domain ID for a switch is beyond the new configured ID list, the configuration will fail. The default value is a zero-length octet string. If This value is set with zero-length, the configuration will be cancelled in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.4 | Hh3cFcDomainIdList | read-write | current |
| hh3cVsanDmDomainIdConfigured OBJECT-TYPE Used to configure or cancel a domain ID for a switch in this VSAN. When this value is not zero, the domain ID type should be specified together via hh3cVsanDmDomainIdTypeConfigured, or the default value of preferred type will be taken. The zero value is used to cancel the domain ID configured, and then, there is no need to specify its type. When statically build a fabric, the configured domain ID is the actual domain ID of the switch. If this object is not manually configured, the switch will isolate all of its E_ports in this VSAN no matter what domain ID type is configured. When dynamically build a fabric, the configured domain ID is desired by the switch, but the domain ID assigned to the switch may not be the desired one. If a non-principal switch fails to obtain any domain ID from the principal switch, the non-principal switch will isolate the upstream link. If a non-principal switch obtains a domain ID from the principal switch other than the desired one, different actions will be taken according to different domain ID type configured: - If configured static type, The non-principal switch will isolate the upstream link and refuse other domain IDs assigned by the principal switch. - If configured preferred type, the non-principal switch will use the domain ID assigned by the principal switch. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.5 | Hh3cFcDomainIdOrZero | read-write | current |
| hh3cVsanDmDomainIdTypeConfigured OBJECT-TYPE Specifies the type of configured domain ID, which can be static type or preferred type. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.6 | INTEGER {static(1), preferred(2)} | read-write | current |
| hh3cVsanDmAutoReconfigureEnable OBJECT-TYPE Used to specify whether a disruptive reconfiguration will be automatically performed when the domain ID lists overlaps in fabric merging. The fabric reconfiguration function takes effect only when the value of hh3cVsanDmDomainConfigureEnable is 'true'. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.7 | TruthValue | read-write | current |
| hh3cVsanDmDomainRestart OBJECT-TYPE Used to manually trigger a disruptive or non-disruptive reconfiguration of the fabric. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.8 | INTEGER {noOperation(1), nonDisruptive(2), disruptive(3)} | read-write | current |
| hh3cVsanDmState OBJECT-TYPE Indicates the managing state of the domain in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.9 | Hh3cFcDmState | read-only | current |
| hh3cVsanDmDomainIdAssigned OBJECT-TYPE Indicates the Domain ID of the local switch in this VSAN or zero if no Domain ID has been assigned. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.10 | Hh3cFcDomainIdOrZero | read-only | current |
| hh3cVsanDmPrincipalSwitchWWN OBJECT-TYPE Indicates the WWN of the principal switch in this VSAN, or zero-length string if the identity of the principal switch is unknown. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.11 | Hh3cFcNameId | read-only | current |
| hh3cVsanDmLocalSwitchWWN OBJECT-TYPE Indicates the WWN of the local switch in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.12 | Hh3cFcNameId | read-only | current |
| hh3cVsanDmPrincipalSwRunPriority OBJECT-TYPE Indicates the running priority of the principal switch in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.13 | Hh3cFcDomainPriority | read-only | current |
| hh3cVsanDmLocalSwRunPriority OBJECT-TYPE Indicates the running priority of the local switch in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.14 | Hh3cFcDomainPriority | read-only | current |
| hh3cVsanDmPrincipalSwSlctCnt OBJECT-TYPE The times that local switch has participated in principal switch selection in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.15 | Counter32 | read-only | current |
| hh3cVsanDmLocalPrincipalSwSlctCnt OBJECT-TYPE The times that local switch was elected as principal switch in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.16 | Counter32 | read-only | current |
| hh3cVsanDmBFCnt OBJECT-TYPE The times that local switch has participated in a BF(Build Fabric) process in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.17 | Counter32 | read-only | current |
| hh3cVsanDmRCFCnt OBJECT-TYPE The times that local switch has participated in a RCF (Reconfigure Fabric) process in this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.18 | Counter32 | read-only | current |
| hh3cVsanDmIfConfigTable OBJECT-TYPE A table contains the FC(Fibre Channel) related interface configurations about domain management of a VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.3 | not-accessible | current | |
| hh3cVsanDmIfConfigEntry OBJECT-TYPE An entry used for managing the FC related interface configurations about domain management of a VSAN. An entry can be created when any object in this table is set to non-default value, and be deleted when the objects in this table are set to default value. | 1.3.6.1.4.1.25506.2.127.1.1.1.3.1 | not-accessible | current | |
| hh3cVsanDmIfConfigRcfReject OBJECT-TYPE Used to specify whether the RCF(Reconfigure Fabric) requests received in this VSAN should be rejected. - true: the received RCF will be rejected. - false: the received RCF will be accepted. | 1.3.6.1.4.1.25506.2.127.1.1.1.3.1.1 | TruthValue | read-write | current |
| hh3cVsanFcIdTable OBJECT-TYPE This table contains FC ID information for each VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.4 | not-accessible | current | |
| hh3cVsanFcIdEntry OBJECT-TYPE This entry provides FC ID information for a VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.4.1 | not-accessible | current | |
| hh3cVsanFreeFcIds OBJECT-TYPE The number of FC IDs that are unassigned on this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.4.1.1 | Counter32 | read-only | current |
| hh3cVsanAssignedFcIds OBJECT-TYPE The number of FC IDs that are assigned on this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.4.1.2 | Counter32 | read-only | current |
| hh3cVsanFcIdPersistency OBJECT-TYPE Enable or disable FC ID persistency on this VSAN. If this object is set to 'true', then all the FC ID assigned on this VSAN are made persistent on this VSAN, and all login entries automatically created in the hh3cVsanFcIdPersistencyTable with hh3cVsanFcIdPersistencyWwn equal to either WWN of the logged-in Nx_Port for which the FC ID was assigned and hh3cVsanFcIdPersistencyType equal to 'dynamic'. If this object is set to 'false', then all the entries on this VSAN in dmFcIdPersistencyTable are deleted. | 1.3.6.1.4.1.25506.2.127.1.1.1.4.1.3 | TruthValue | read-write | current |
| hh3cVsanFcIdPurge OBJECT-TYPE This object is used to purge the FC ID persistency database on this VSAN. If the value of this object is 'enable', then all entries on this VSAN in the hh3cVsanFcIdPersistencyTable with hh3cVsanFcIdPersistencyType is 'dynamic' and hh3cVsanFcIdPersistencyUsed is 'false' are purged from the persistency database. | 1.3.6.1.4.1.25506.2.127.1.1.1.4.1.4 | INTEGER {noOp(1), enable(2)} | read-write | current |
| hh3cVsanFcIdPersistencyTable OBJECT-TYPE This table contains the FC IDs which are in the FC ID persistency database of each VSAN. If the FC ID persistency is enabled, FC devices would get the same FC IDs even if they disappear and appear again. The FC ID persistency database contains information about the FC IDs which are assigned to FC devices either statically (configured) or dynamically. An entry is automatically created when a FC ID is assigned and hh3cVsanFcIdPersistency is 'true' on this VSAN. The entries can also be created and deleted via the hh3cVsanFcIdPersistencyRowStatus object. If the object hh3cVsanFcIdPurge is set to 'enable', an entry is deleted if its hh3cVsanFcIdPersistencyType is 'dynamic' and hh3cVsanFcIdPersistencyUsed is 'false'. If the hh3cVsanFcIdPersistency is 'false', no entry can be created. If the hh3cVsanDmDomainIdAssigned is changed on a VSAN, then all the entries on that VSAN in this table are deleted. | 1.3.6.1.4.1.25506.2.127.1.1.1.5 | not-accessible | current | |
| hh3cVsanFcIdPersistencyEntry OBJECT-TYPE This entry provides FC ID persistency information for a VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.5.1 | not-accessible | current | |
| hh3cVsanFcIdPersistencyWwn OBJECT-TYPE This is either the port WWN of the FC device if the local port is an F_port. The local port is the port on the local device to which the FC device is attached. | 1.3.6.1.4.1.25506.2.127.1.1.1.5.1.1 | Hh3cFcNameId | not-accessible | current |
| hh3cVsanFcIdPersistencyFcId OBJECT-TYPE The FC ID assigned for this WWN on this VSAN. This object cannot be changed if either the value of hh3cVsanFcIdPersistencyUsed is 'true' or if the new value being set is already assigned on this VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.1.5.1.2 | Hh3cFcAddressId | read-create | current |
| hh3cVsanFcIdPersistencyUsed OBJECT-TYPE This object indicates this FC ID is used or not. | 1.3.6.1.4.1.25506.2.127.1.1.1.5.1.3 | TruthValue | read-only | current |
| hh3cVsanFcIdPersistencyType OBJECT-TYPE The type of persistency of this FC ID. | 1.3.6.1.4.1.25506.2.127.1.1.1.5.1.4 | INTEGER {static(1), dynamic(2)} | read-create | current |
| hh3cVsanFcIdPersistencyRowStatus OBJECT-TYPE An entry cannot be created if hh3cVsanFcIdPersistency is 'false'. An entry cannot be deleted if hh3cVsanFcIdPersistencyUsed is 'true'. | 1.3.6.1.4.1.25506.2.127.1.1.1.5.1.5 | RowStatus | read-create | current |
| hh3cVsanDmInformation OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1.1.2 | |||
| hh3cVsanDmDatabaseTable OBJECT-TYPE A table specifies the information of the switch about all the Domain IDs which have been assigned in each of the VSANs. | 1.3.6.1.4.1.25506.2.127.1.1.2.1 | not-accessible | current | |
| hh3cVsanDmDatabaseEntry OBJECT-TYPE An object in the hh3cVsanDmDatabaseTable contains one Domain ID and the corresponding WWN of the switch in one VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.2.1.1 | not-accessible | current | |
| hh3cVsanDmDatabaseDomainId OBJECT-TYPE The Domain ID which has been assigned. | 1.3.6.1.4.1.25506.2.127.1.1.2.1.1.1 | Hh3cFcDomainId | not-accessible | current |
| hh3cVsanDmDatabaseSwitchWWN OBJECT-TYPE The WWN of the switch to which the corresponding Domain ID has been assigned in the particular VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.2.1.1.2 | Hh3cFcNameId | read-only | current |
| hh3cVsanDmIfInfoTable OBJECT-TYPE A table specifies the information of an interface in each of the VSANs. | 1.3.6.1.4.1.25506.2.127.1.1.2.2 | not-accessible | current | |
| hh3cVsanDmIfInfoEntry OBJECT-TYPE A conceptual row in the hh3cVsanDmIfInfoTable indicates the role information of the interface in the particular VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.2.2.1 | not-accessible | current | |
| hh3cVsanDmIfInfoRole OBJECT-TYPE The role of the interface in the VSAN. The value specifications are listed as follows: nonPrincipal - The state of the interface is not principal interface in the VSAN. principalUpstream - The state of the interface is upstream principal interface in the VSAN. principalDownstream - The state of the interface is downstream principal interface in the VSAN. isolated - The state of the interface is isolated in the VSAN. unknown - The state of the interface is unknown in the VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.2.2.1.1 | INTEGER {nonPrincipal(1), principalUpstream(2), principalDownstream(3), isolated(4), unknown(5)} | read-only | current |
| hh3cVsanDmNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1.1.3 | |||
| hh3cVsanDmNotificationPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1.1.3.0 | |||
| hh3cVsanDmNotificationSwitch OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.127.1.1.3.1 | |||
| hh3cVsanDmFabricChangeNotifyEnable OBJECT-TYPE Specifies whether the hh3cVsanDmFabricChangeNotify can be sent when a BF or RCF message was sent or received by a switch. | 1.3.6.1.4.1.25506.2.127.1.1.3.1.1 | TruthValue | read-write | current |
| hh3cVsanDmDomainIdChangeNotifyEnable OBJECT-TYPE Specifies whether the hh3cVsanDmDomainIdChangeNotify can be sent when the Domain ID of the local switch changed in a VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.3.1.2 | TruthValue | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| hh3cVsanDmDomainIdNotAssignedNotify NOTIFICATION-TYPE This event will be triggered if a Domain ID is not assigned or configured, then the E_ports may be isolated in the VSAN. The conditions are listed as follows: 1. If the switch has enabled the fabric configuration and a request for a configured static Domain ID is rejected or no other Domain ID is assigned, the E_ports will be isolated in the particular VSAN. 2. If the switch does not enable the fabric configuration and a Domain ID is not configured, all of its E_ports will be isolated in the particular VSAN. The notification contains the WWN of the Switch and the index of the VSAN in which the event occurred. | 1.3.6.1.4.1.25506.2.127.1.1.3.0.1 | current |
| hh3cVsanDmNewPrincipalSwitchNotify NOTIFICATION-TYPE If a switch becomes the new Principal Switch in a VSAN, this notification is sent immediately after the election. The notification contains the WWN of the new Principal Switch and the index of the VSAN in which the transition occurred. | 1.3.6.1.4.1.25506.2.127.1.1.3.0.2 | current |
| hh3cVsanDmFabricChangeNotify NOTIFICATION-TYPE This event will be triggered if a switch sends or receives a Build Fabric (BF) or a Reconfigure Fabric (RCF) message in a VSAN. The conditions a switch can receive or send a BF or a RCF are listed as follows: 1. Two isolated fabrics in a VSAN merge into one fabric. If the Domain ID lists do not overlap, the sent or received message is BF, other cases, it is RCF. 2. If an upstream principal link which connects to principal switch and other switches become disconnected, the sent or received message is BF. 3. A BF or RCF process is triggered manually by configuration. The notification contains the index of the VSAN in which a BF or a RCF was sent or received. | 1.3.6.1.4.1.25506.2.127.1.1.3.0.3 | current |
| hh3cVsanDmDomainIdChangeNotify NOTIFICATION-TYPE This event will be triggered if the Domain ID of the local switch changed in a VSAN. | 1.3.6.1.4.1.25506.2.127.1.1.3.0.4 | current |