HH3C-SECHIGH-MIB
- Registered at
- 1.3.6.1.4.1.25506.2.171
- Last updated
- 2021-02-03 00:00
- Organization
- New H3C Technologies Co., Ltd.
- Revisions
- 2021-02-03 00:00, 2021-01-06 00:00, 2020-05-29 00:00, 2017-09-16 20:20
- Namespace
- comware
- Source file
HH3C-SECHIGH-MIB- Digest
sha256:7cfb6d00a391e898e2cb9afcb1a130a01c170c8fec22ef6812f329e6ce2ce1a9
Description
The private MIB file includes the information on high-end driver products.
Contact
Platform Team New H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085
Imports
| From | Symbols |
|---|---|
| HH3C-OID-MIB | hh3cCommon |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HH3C-OID-MIB HH3C-SECHIGH-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hh3cSecHighMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1 | |||
| hh3cSecHighHgMonitorAlarmVar OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.1 | |||
| hh3cSecHighHgMonitorAlarmType OBJECT-TYPE Type of the alarm,0 represent recovery normal,1 represent link status error, 2 represent Some packets were dropped on the link. | 1.3.6.1.4.1.25506.2.171.1.1.1 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmSrcChassis OBJECT-TYPE Number of the chassis where the source end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.2 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmSrcSlot OBJECT-TYPE Number of the slot where the source end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.3 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmSrcChip OBJECT-TYPE Number of the chip where the source end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.4 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmSrcPort OBJECT-TYPE Number of the port where the source end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.5 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmDstChassis OBJECT-TYPE Number of the chassis where the destination end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.6 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmDstSlot OBJECT-TYPE Number of the slot where the destination end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.7 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmDstChip OBJECT-TYPE Number of the chip where the destination end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.8 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmDstPort OBJECT-TYPE Number of the port where the destination end of the alarmed link resides. | 1.3.6.1.4.1.25506.2.171.1.1.9 | Integer32 | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmReason OBJECT-TYPE Cause of the alarm. | 1.3.6.1.4.1.25506.2.171.1.1.10 | OCTET STRING (SIZE(0..512)) | accessible-for-notify | current |
| hh3cSecHighHgMonitorAlarmTrap OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.2 | |||
| hh3cSecHighHgMonitorAlarmNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.2.0 | |||
| hh3cSecHighFaultMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.3 | |||
| hh3cSecHighFaultAlmVar OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.3.1 | |||
| hh3cSecHighFaultAlmType OBJECT-TYPE Type of the alarm, 1 represents Hg link status error, 2 represents Hg packet loss error, 3 represents back board E2PROM error, 4 represents board E2PROM error, 5 represents CPLD chip error, 101 to 200 represent FPGA errors. | 1.3.6.1.4.1.25506.2.171.1.3.1.1 | Integer32 | accessible-for-notify | current |
| hh3cSecHighFaultAlmChassis OBJECT-TYPE Number of the chassis in which error occurs. | 1.3.6.1.4.1.25506.2.171.1.3.1.2 | Integer32 | accessible-for-notify | current |
| hh3cSecHighFaultAlmSlot OBJECT-TYPE Number of the slot in which error occurs. | 1.3.6.1.4.1.25506.2.171.1.3.1.3 | Integer32 | accessible-for-notify | current |
| hh3cSecHighFaultAlmDstChassis OBJECT-TYPE Number of the destination chassis in which Hg error occurs. | 1.3.6.1.4.1.25506.2.171.1.3.1.4 | Integer32 | accessible-for-notify | current |
| hh3cSecHighFaultAlmDstSlot OBJECT-TYPE Number of the destination slot in which Hg error occurs. | 1.3.6.1.4.1.25506.2.171.1.3.1.5 | Integer32 | accessible-for-notify | current |
| hh3cSecHighFaultAlmChip OBJECT-TYPE Id of the error chip. | 1.3.6.1.4.1.25506.2.171.1.3.1.6 | Integer32 | accessible-for-notify | current |
| hh3cSecHighFaultAlmInfo OBJECT-TYPE Details of the alarm notification. | 1.3.6.1.4.1.25506.2.171.1.3.1.7 | OCTET STRING (SIZE(0..512)) | accessible-for-notify | current |
| hh3cSecHighFaultAlmTrap OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.3.2 | |||
| hh3cSecHighFaultAlmTrapPre OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.1.3.2.0 | |||
| hh3cSecHighTemperMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.2 | |||
| hh3cSecHighTemperAlarmVar OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.2.1 | |||
| hh3cSecHighTemperAlarmChassis OBJECT-TYPE Number of the chassis in which temperature exdceeds the shutdown threshold. | 1.3.6.1.4.1.25506.2.171.2.1.1 | Integer32 | accessible-for-notify | current |
| hh3cSecHighTemperAlarmSlot OBJECT-TYPE Number of the slot in which temperature exdceeds the shutdown threshold. | 1.3.6.1.4.1.25506.2.171.2.1.2 | Integer32 | accessible-for-notify | current |
| hh3cSecHighTemperAlarmHotspotIndx OBJECT-TYPE Index of the hotspot of which temperature exdceeds the shutdown threshold. | 1.3.6.1.4.1.25506.2.171.2.1.3 | Integer32 | accessible-for-notify | current |
| hh3cSecHighTemperAlarmCurTemper OBJECT-TYPE Current temperature of the hotspot that exceeds the high temperature shutdown threshold. | 1.3.6.1.4.1.25506.2.171.2.1.4 | Integer32 | accessible-for-notify | current |
| hh3cSecHighTemperAlarmLimit OBJECT-TYPE The power down threshold of ehe equipment. | 1.3.6.1.4.1.25506.2.171.2.1.5 | Integer32 | accessible-for-notify | current |
| hh3cSecHighTemperAlarmTrap OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.2.2 | |||
| hh3cSecHighTemperAlmTrapPre OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.2.2.0 | |||
| hh3cSecHighParityErrorMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.3 | |||
| hh3cSecHighParityErrorAlarmVar OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.3.1 | |||
| hh3cSecHighParityErrorAlarmChassis OBJECT-TYPE Number of the chassis in which Parity Error occurs. | 1.3.6.1.4.1.25506.2.171.3.1.1 | Integer32 | accessible-for-notify | current |
| hh3cSecHighParityErrorAlarmSlot OBJECT-TYPE Number of the slot in which Parity Error occurs. | 1.3.6.1.4.1.25506.2.171.3.1.2 | Integer32 | accessible-for-notify | current |
| hh3cSecHighParityErrorAlarmChipUnit OBJECT-TYPE Number of the ChipUnit of which Parity Error occurs. | 1.3.6.1.4.1.25506.2.171.3.1.3 | Integer32 | accessible-for-notify | current |
| hh3cSecHighParityErrorAlarmTrap OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.3.2 | |||
| hh3cSecHighParityErrorAlarmTrapPre OBJECT-IDENTITY | 1.3.6.1.4.1.25506.2.171.3.2.0 |
Notifications
| Name | OID | Status |
|---|---|---|
| hh3cSecHighHgMonitorAlarmNotification NOTIFICATION-TYPE This notification is generated when an HgMonitor alarm is generated. | 1.3.6.1.4.1.25506.2.171.1.2.0.1 | current |
| hh3cSecHighFaultMonChipAlmNotifi NOTIFICATION-TYPE This notification is generated when a chip error occurs. | 1.3.6.1.4.1.25506.2.171.1.3.2.0.1 | current |
| hh3cSecHighFaultMonChipAlmResu NOTIFICATION-TYPE This notification is generated when a chip error is recovered. | 1.3.6.1.4.1.25506.2.171.1.3.2.0.2 | current |
| hh3cSecHighFaultMonHgAlmNotifi NOTIFICATION-TYPE This notification is generated when an Hg error occurs. | 1.3.6.1.4.1.25506.2.171.1.3.2.0.3 | current |
| hh3cSecHighFaultMonHgAlmResu NOTIFICATION-TYPE This notification is generated when an Hg error is recovered. | 1.3.6.1.4.1.25506.2.171.1.3.2.0.4 | current |
| hh3cSecHighTemperAlarmNotify NOTIFICATION-TYPE This notification is generated when a hotspot's temperature exceeds its power down threshold. | 1.3.6.1.4.1.25506.2.171.2.2.0.1 | current |
| hh3cSecHighParityErrorAlarmNotify NOTIFICATION-TYPE This notification is generated when a severe parity error occurs. | 1.3.6.1.4.1.25506.2.171.3.2.0.1 | current |