HH3C-LswMix-MIB
- Registered at
- 1.3.6.1.4.1.25506.8.35.17
- Last updated
- 2001-06-29 00:00
- Organization
- New H3C Tech. Co., Ltd.
- Revisions
- 2001-06-29 00:00
- Namespace
- comware
- Source file
HH3C-LswMix-MIB- Digest
sha256:9f70e18e22f9919afb0e70e876b5451b5405c9b24b8943b917f3fe929d72192e
Contact
Platform Team New H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085
Imports
| From | Symbols |
|---|---|
| HH3C-LSW-DEV-ADM-MIB | hh3cLswFrameIndex, hh3cLswSlotIndex |
| HH3C-OID-MIB | hh3clswCommon |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HCNUM-TC HH3C-LSW-DEV-ADM-MIB HH3C-LswMix-MIB HH3C-OID-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| hh3cLswLastSwitchDate OBJECT-TYPE This object indicates the date of the most recent change to the mpu(Main Processing Unit). | 1.3.6.1.4.1.25506.8.35.17.1 | INTEGER | read-only | current |
| hh3cLswLastSwitchTime OBJECT-TYPE This object indicates the time of the most recent change to the mpu. | 1.3.6.1.4.1.25506.8.35.17.2 | INTEGER | read-only | current |
| hh3cLswMpuSwitchsNum OBJECT-TYPE This object indicates the total times of the mpu switched since the system start up. | 1.3.6.1.4.1.25506.8.35.17.3 | INTEGER | read-only | current |
| hh3cLswMpuSwitch OBJECT-TYPE Setting this object will immediately switch the standby mpu to master mpu. Read is not supported. | 1.3.6.1.4.1.25506.8.35.17.4 | INTEGER {switch(1)} | read-write | current |
| hh3cLswXSlotTable OBJECT-TYPE The source main table. | 1.3.6.1.4.1.25506.8.35.17.5 | not-accessible | current | |
| hh3cLswXSlotEntry OBJECT-TYPE An entry in the source main table. | 1.3.6.1.4.1.25506.8.35.17.5.1 | not-accessible | current | |
| hh3cLswMainCardBoardStatus OBJECT-TYPE The value describes whether the board is master, standby or process. master and standby are the possible states for the mpu, while process indicates the state of lpu(Line Processing Unit) | 1.3.6.1.4.1.25506.8.35.17.5.1.1 | INTEGER {master(1), standby(2), process(3)} | read-only | current |
| hh3cLswCrossBarStatus OBJECT-TYPE The value describes whether the crossbar is master or standby. It is master when it's in the master mpu board, standby when in the standby mpu. But both crossbars in mpus are master when the device in load-balance mode. | 1.3.6.1.4.1.25506.8.35.17.5.1.2 | INTEGER {master(1), standby(2)} | read-only | current |
| hh3csMixTrapMib OBJECT-IDENTITY | 1.3.6.1.4.1.25506.8.35.17.10 |
Notifications
| Name | OID | Status |
|---|---|---|
| hh3cSlaveSwitchOver NOTIFICATION-TYPE An hh3cSlaveSwitchOver trap signifies that the action of standby mpu switching to master has completed. | 1.3.6.1.4.1.25506.8.35.17.10.1 | current |