H3C-VOICE-IF-MIB
- Registered at
- 1.3.6.1.4.1.2011.10.2.39.13
- Last updated
- 2007-12-10 17:00
- Organization
- Hangzhou H3C Technologies Co., Ltd.
- Revisions
- 2007-12-10 17:00
- Namespace
- huawei
- Source file
H3C-VOICE-IF-MIB- Digest
sha256:d7c15fed69ac5cd44b22bae292122b9944683d84f97a53a848526c93e1385c41
Description
This MIB file is to provide the definition of the voice interface general configuration.
Contact
Platform Team H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.h3c.com Zip:100085
Imports
| From | Symbols |
|---|---|
| HUAWEI-3COM-OID-MIB | h3cVoice |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
H3C-VOICE-IF-MIB HUAWEI-3COM-OID-MIB IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| h3cVoiceIfObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.39.13.1 | |||
| h3cVoiceIfConfigTable OBJECT-TYPE The table contains configurable parameters for both analog voice interface and digital voice interface. | 1.3.6.1.4.1.2011.10.2.39.13.1.1 | not-accessible | current | |
| h3cVoiceIfConfigEntry OBJECT-TYPE The entry of voice interface table. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1 | not-accessible | current | |
| h3cVoiceIfCfgCngOn OBJECT-TYPE This object indicates whether the silence gaps should be filled with background noise. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.1 | INTEGER {enable(1), disable(2)} | read-write | current |
| h3cVoiceIfCfgNonLinearSwitch OBJECT-TYPE This object expresses the nonlinear processing is enable or disable for the voice interface. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. Currently, only digital voice subscriber lines can be set disabled. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.2 | INTEGER {enable(1), disable(2)} | read-write | current |
| h3cVoiceIfCfgInputGain OBJECT-TYPE This object indicates the amount of gain added to the receiver side of the voice interface. Unit is 0.1 db. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.3 | Integer32 (-140..139) | read-write | current |
| h3cVoiceIfCfgOutputGain OBJECT-TYPE This object indicates the amount of gain added to the send side of the voice interface. Unit is 0.1 db. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.4 | Integer32 (-140..139) | read-write | current |
| h3cVoiceIfCfgEchoCancelSwitch OBJECT-TYPE This object indicates whether the echo cancellation is enabled. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.5 | INTEGER {enable(1), disable(2)} | read-write | current |
| h3cVoiceIfCfgEchoCancelDelay OBJECT-TYPE This object indicates the delay of the echo cancellation for the voice interface. This value couldn't be modified unless h3cVoiceIfCfgEchoCancelSwitch is enable. Unit is milliseconds. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. The default value of this object is 32. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.6 | Integer32 (0..64) | read-write | current |
| h3cVoiceIfCfgTimerDialInterval OBJECT-TYPE The interval, in seconds, between two dialing numbers. The default value of this object is 10 seconds. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 with loop-start or ground-start protocol voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.7 | Integer32 (1..300) | read-write | current |
| h3cVoiceIfCfgTimerFirstDial OBJECT-TYPE The period of time, in seconds, before dialing the first number. The default value of this object is 10 seconds. It is applicable to FXO, FXS subscriber lines and E1/T1 with loop-start or ground-start protocol voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.8 | Integer32 (1..300) | read-write | current |
| h3cVoiceIfCfgPrivateline OBJECT-TYPE This object indicates the E.164 phone number for plar mode. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.9 | DisplayString (SIZE(0..31)) | read-write | current |
| h3cVoiceIfCfgRegTone OBJECT-TYPE This object uses 2 or 3 letter country code specify voice parameters of different countrys. This value will take effect on all voice interfaces of all cards on the device. | 1.3.6.1.4.1.2011.10.2.39.13.1.1.1.10 | OCTET STRING (SIZE(0 | 2..3)) | read-write | current |