MIBs Depot

H3C-TE-TUNNEL-MIB

Registered at
1.3.6.1.4.1.43.45.1.10.2.115
Last updated
2011-03-24 09:48
Organization
Hangzhou H3C Tech. Co., Ltd.
Namespace
3com
Source file
H3C-TE-TUNNEL-MIB
Digest
sha256:c6bbd1a0a84ead717b3e9f80fe9f425938cb79fbb86d16c906ba42b175e673fc

Description

This MIB contains managed object definitions for the Multiprotocol Label Switching (MPLS) Te Tunnel.

Contact

Platform Team Hangzhou H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085

Imports

FromSymbols
A3COM-HUAWEI-OID-MIBh3cCommon
MPLS-TC-STD-MIBMplsExtendedTunnelId, MplsLabel, MplsTunnelIndex, MplsTunnelInstanceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, RowPointer, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

A3COM-HUAWEI-OID-MIB
H3C-TE-TUNNEL-MIB
MPLS-TC-STD-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
h3cTeTunnelScalars
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.1
h3cTeTunnelMaxTunnelIndex
OBJECT-TYPE
The max value of tunnel id is permitted configure on the device.
1.3.6.1.4.1.43.45.1.10.2.115.1.1MplsTunnelIndexread-onlycurrent
h3cTeTunnelObjects
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.2
h3cTeTunnelStaticCrlspTable
OBJECT-TYPE
This table contains information for static-crlsp, and through this to get detail information about this static-crlsp. Only support transit LSR and egress LSR.
1.3.6.1.4.1.43.45.1.10.2.115.2.1not-accessiblecurrent
h3cTeTunnelStaticCrlspEntry
OBJECT-TYPE
The entry in this table describes static-crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1not-accessiblecurrent
h3cTeTunnelStaticCrlspInLabel
OBJECT-TYPE
This is unique label value that manualy assigned. Uniquely identifies a static-crlsp. Managers should use this to obtain detail static-crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.1MplsLabelnot-accessiblecurrent
h3cTeTunnelStaticCrlspName
OBJECT-TYPE
The unique name assigned to the static-crlsp.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.2OCTET STRING (SIZE(1..15))read-onlycurrent
h3cTeTunnelStaticCrlspStatus
OBJECT-TYPE
Indicates the actual status of this static-crlsp, The value must be up when the static-crlsp status is up and the value must be down when the static-crlsp status is down.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.3INTEGER {up(1), down(2)}read-onlycurrent
h3cTeTunnelStaticCrlspRole
OBJECT-TYPE
This value indicate the role of this static-crlsp. This value must be transit at transit point of the tunnel, and tail at terminating point of the tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.4INTEGER {transit(1), tail(2)}read-onlycurrent
h3cTeTunnelStaticCrlspXCPointer
OBJECT-TYPE
This pointer unique identify a row of mplsXCTable. This value should be zeroDotZero when the static-crlsp is down. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relationships to each other.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.5RowPointerread-onlycurrent
h3cTeTunnelCoTable
OBJECT-TYPE
This table contains information for Co-routed reverse crlsp and infomation of Co-routed bidirectional Tunnel Interface. If h3cCorouteTunnelLspInstance is zero, to obtain infomation of Co-routed bidirectional Tunnel Interface, otherwise to obtain Co-routed reverse crlsp infomation.
1.3.6.1.4.1.43.45.1.10.2.115.2.2not-accessiblecurrent
h3cTeTunnelCoEntry
OBJECT-TYPE
The entry in this table describes Co-routed infomation of bidirectional Tunnel Interface and reserver lsp information.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1not-accessiblecurrent
h3cTeTunnelCoIndex
OBJECT-TYPE
Uniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs that specified at originating point. This value should be equal to the value signaled in the Tunnel Id of the Session object.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.1MplsTunnelIndexnot-accessiblecurrent
h3cTeTunnelCoLspInstance
OBJECT-TYPE
When obtain infomation of Co-routed bidirectional Tunnel Interface, this vlaue should be zero. And this value must be LspID to obtain reverse crlsp information. Values greater than 0, but less than or equal to 65535, should be useless.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.2MplsTunnelInstanceIndexnot-accessiblecurrent
h3cTeTunnelCoIngressLSRId
OBJECT-TYPE
Identity the ingress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of originating endpoint.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.3MplsExtendedTunnelIdnot-accessiblecurrent
h3cTeTunnelCoEgressLSRId
OBJECT-TYPE
Identity of the egress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of terminating point.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.4MplsExtendedTunnelIdnot-accessiblecurrent
h3cTeTunnelCoBiMode
OBJECT-TYPE
This vlaue indicated the bidirection mode of tunnel interface. The valuemust be coroutedActive at the originating point of the tunnel and coroutedPassive at the terminating point.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.5INTEGER {coroutedActive(1), coroutedPassive(2)}read-onlycurrent
h3cTeTunnelCoReverseLspInstance
OBJECT-TYPE
This value indicated the reverse lsp instance, and should be equal to obverse lsp instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.6MplsTunnelInstanceIndexread-onlycurrent
h3cTeTunnelCoReverseLspXCPointer
OBJECT-TYPE
This pointer unique index to mplsXCTable of the reverse lsp. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relationships to each other. A value of zeroDotZero indicate that there is no crlsp assigned to this.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.7RowPointerread-onlycurrent
h3cTeTunnelPsTable
OBJECT-TYPE
This table defines some objects for managers to obtain TE tunnel Protection Switching group current status information.
1.3.6.1.4.1.43.45.1.10.2.115.2.3not-accessiblecurrent
h3cTeTunnelPsEntry
OBJECT-TYPE
The entry in this table describes TE tunnel Protection Switching group infromation.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1not-accessiblecurrent
h3cTeTunnelPsIndex
OBJECT-TYPE
Uniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of work tunnel instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.1MplsTunnelIndexnot-accessiblecurrent
h3cTeTunnelPsIngressLSRId
OBJECT-TYPE
Identity the ingress LSR associated with work tunnel instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.2MplsExtendedTunnelIdnot-accessiblecurrent
h3cTeTunnelPsEgressLSRId
OBJECT-TYPE
Identity of the egress LSR associated with work tunnel instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.3MplsExtendedTunnelIdnot-accessiblecurrent
h3cTeTunnelPsProtectIndex
OBJECT-TYPE
Uniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of TE tunnel Protection Switching group instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.4MplsTunnelIndexread-onlycurrent
h3cTeTunnelPsProtectIngressLSRId
OBJECT-TYPE
Identity the ingress LSR associated with TE tunnel Protection Switching group instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.5MplsExtendedTunnelIdread-onlycurrent
h3cTeTunnelPsProtectEgressLSRId
OBJECT-TYPE
Identity of the egress LSR associated with TE tunnel Protection Switching group instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.6MplsExtendedTunnelIdread-onlycurrent
h3cTeTunnelPsProtectType
OBJECT-TYPE
This value indicated TE tunnel Protection Switching group type. The default value is oneToOne.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.7INTEGER {oneToOne(1), onePlusOne(2)}read-onlycurrent
h3cTeTunnelPsRevertiveMode
OBJECT-TYPE
This value indicated protect switch mode. The value must be revertive or nonRevertive, default value is revertive.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.8INTEGER {revertive(1), noRevertive(2)}read-onlycurrent
h3cTeTunnelPsWtrTime
OBJECT-TYPE
The cycle time that switch to protect tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.9Unsigned32 (0..60)read-onlycurrent
h3cTeTunnelPsHoldOffTime
OBJECT-TYPE
This value is switchback delay time. When detected the work path fault, switch to protect path after this time.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.10Unsigned32 (0..20)read-onlycurrent
h3cTeTunnelPsSwitchMode
OBJECT-TYPE
This value indicated TE tunnel Protection Switching group switch mode.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.11INTEGER {uniDirectional(1), biDirectional(2)}read-onlycurrent
h3cTeTunnelPsWorkPathStatus
OBJECT-TYPE
This value indicates work path status. none, noDefect, inDefect will be used.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.12INTEGER {none(1), noDefect(2), inDefect(3)}read-onlycurrent
h3cTeTunnelPsProtectPathStatus
OBJECT-TYPE
This value indicates protect path status. none, noDefect, inDefect(3) will be used.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.13INTEGER {none(1), noDefect(2), inDefect(3)}read-onlycurrent
h3cTeTunnelPsSwitchResult
OBJECT-TYPE
This value indicated current using path is work path or protect path.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.14INTEGER {workPath(1), protectPath(2)}read-onlycurrent
h3cTeTunnelNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.3
h3cTeTunnelNotificationsPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.3.0
h3cTeTunnelConformance
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.4
h3cTeTunnelCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.4.1
h3cTeTunnelGroups
OBJECT-IDENTITY
1.3.6.1.4.1.43.45.1.10.2.115.4.2

Notifications

NameOIDStatus
h3cTeTunnelPsSwitchWtoP
NOTIFICATION-TYPE
This notification is generated when protect workgroup switch from work tunnel to protect tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.3.0.1current
h3cTeTunnelPsSwitchPtoW
NOTIFICATION-TYPE
This notification is generated when protect workgroup switch from protect tunnel to work tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.3.0.2current

Conformance

NameOIDStatus
h3cTeTunnelCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP.
1.3.6.1.4.1.43.45.1.10.2.115.4.1.1current
h3cTeTunnelNotificationsGroup
NOTIFICATION-GROUP
This group contains MPLS Te Tunnel traps.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.1current
h3cTeTunnelScalarsGroup
OBJECT-GROUP
Scalar object needed to implement MPLS te tunnels.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.2current
h3cTeTunnelStaticCrlspGroup
OBJECT-GROUP
Objects for quering static-crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.3current
h3cTeTunnelCorouteGroup
OBJECT-GROUP
Objects for quering Co-routed reverse crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.4current
h3cTeTunnelPsGroup
OBJECT-GROUP
Objects for quering protect workgroup information.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.5current