H3C-POWER-ETH-EXT-MIB
- Registered at
- 1.3.6.1.4.1.2011.10.2.14
- Last updated
- 2004-07-26 10:23
- Organization
- Organization.
- Namespace
- huawei
- Source file
H3C-POWER-ETH-EXT-MIB- Digest
sha256:59441c090cd058264c8efdac95af2161053860233b166d08417e22f7dff12b28
Description
Description.
Contact
Contact-info.
Imports
| From | Symbols |
|---|---|
| HUAWEI-3COM-OID-MIB | h3cCommon |
| POWER-ETHERNET-MIB | pethMainPseGroupIndex, pethPsePortDetectionStatus, pethPsePortGroupIndex, pethPsePortIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
H3C-POWER-ETH-EXT-MIB HUAWEI-3COM-OID-MIB POWER-ETHERNET-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ACAlarmState type | ||||
| DCAlarmState type | ||||
| ModuleAlarmState type | ||||
| SwitchState type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| h3cPsePortTable OBJECT-TYPE The indexing scheme is taken form that used by the IETF Power MIB. The same indexing scheme is used to give continuity in behaviour between that standard and this extensions definitioin. | 1.3.6.1.4.1.2011.10.2.14.1 | not-accessible | current | |
| h3cPsePortEntry OBJECT-TYPE The pethPsePortGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. Group means (box in the stack, module in a rack). The pethPsePortPowerIndex is imported from the IETF Power MIB and uniquely identifies the power ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected. This value will match the local port number on a switch. | 1.3.6.1.4.1.2011.10.2.14.1.1 | not-accessible | current | |
| h3cPsePortFaultDescription OBJECT-TYPE The object supports the fault category of the IETF Power MIB [1] pethPsePortDetectionStatus object. A textual description containing more information about the nature of this fault is provided by this object. Typically this will detail the precise PoE hardware state which is causing the pethPsePortDetectionStatus object to be in the 'fault' state. It is a DisplayString of up to 255 characters. | 1.3.6.1.4.1.2011.10.2.14.1.1.2 | DisplayString | read-write | current |
| h3cPsePortPeakPower OBJECT-TYPE The object specifies the peak power which has been consumed by the port. It is defined as the highest measured value of power in milliWatts that has been consumed by the port. Its value is only reset when link is lost, the port is PoE disabled or when it is manually reset by the user asspecified below. It is a read/write integer value with units of milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. | 1.3.6.1.4.1.2011.10.2.14.1.1.3 | Integer32 | read-write | current |
| h3cPsePortAveragePower OBJECT-TYPE The object specifies the average power which has been consumed by the port. This object is a read/write integer value with units of milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. | 1.3.6.1.4.1.2011.10.2.14.1.1.4 | Integer32 | read-write | current |
| h3cPsePortCurrentPower OBJECT-TYPE The object specifies the power currently being consumed by the port. It is a read only integer value with units of milliWatts. | 1.3.6.1.4.1.2011.10.2.14.1.1.5 | Integer32 | read-only | current |
| h3cPsePortPowerLimit OBJECT-TYPE The object specifies the power limit set for this port. The PSE will not supply more than this level of power to the specified port. It is a read/write integer value with units of milliWatts. | 1.3.6.1.4.1.2011.10.2.14.1.1.6 | Integer32 | read-write | current |
| h3cPsePortProfileIndex OBJECT-TYPE Indicates the power profile which is currently associated with this port. This object references the corresponding h3cPseProfileIndex object in the power profiles table. A value of zero is a special case and indicates that no power profile is currently associated with this port. When h3cPseProfileIndex is set to an index of existent profile, pethPsePortPowerPairs, pethPsePortPowerPriority, pethPsePortAdminEnable and h3cPsePortPowerLimit will be set to the same as corresponding value. PethPsePortPowerPairs, pethPsePortPowerPriority and pethPsePortAdminEnable are objects of rfc3621-Power-Ethernet.mib. | 1.3.6.1.4.1.2011.10.2.14.1.1.7 | Integer32 (0..100) | read-write | current |
| h3cMainPseTable OBJECT-TYPE Description. | 1.3.6.1.4.1.2011.10.2.14.2 | not-accessible | current | |
| h3cMainPseEntry OBJECT-TYPE The pethMainPseGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. | 1.3.6.1.4.1.2011.10.2.14.2.1 | not-accessible | current | |
| h3cMainPsePowerLimit OBJECT-TYPE The object specifies the power limit set for the unit as a whole. The PoE unit will already have a nominal power defined by the IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object specifies a further limit to this nominal power value. This may be useful to control the thermals of the unit, or for internal testing purposes. One possible use for this object may be to lower the power consumption of the unit if one or more of the internal fans have broken. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). | 1.3.6.1.4.1.2011.10.2.14.2.1.1 | Integer32 | read-write | current |
| h3cMainPseAveragePower OBJECT-TYPE The object specifies the average power which has been consumed by the port. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. | 1.3.6.1.4.1.2011.10.2.14.2.1.2 | Integer32 | read-write | current |
| h3cMainPsePeakPower OBJECT-TYPE The object specifies the peak power which has been consumed for PoE. It is defined as the highest measured value of power in milliWatts that has been consumed at any one point in time by the sum of the PoE ports. Its value is only reset when the unit is powered on or when it is manually reset by the user as specifiedbelow. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). Writing a value of zero to this object resets its value to zero. Writing any other value to this object has noeffect on its value and an error is returned. | 1.3.6.1.4.1.2011.10.2.14.2.1.3 | Integer32 | read-write | current |
| h3cMainGuaranteedPowerRemaining OBJECT-TYPE The object specifies the amount of power remaining in the guaranteed power pool. Each time a port is placed into guaranteed mode it reserves a set amount of power out of the total guaranteed power pool for the system. This intention of this object is to give the client of this MIB (whether that be the CLI or the Web interface or the end user) an indication of how many ports can still be placed into guaranteed mode. It is a read only integer value with units of Watts(note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters,such as the pethMainPsePower object, in units of Watts). | 1.3.6.1.4.1.2011.10.2.14.2.1.4 | Integer32 | read-only | current |
| h3cMainPsePriorityMode OBJECT-TYPE Describes or controls the priority mode on slot which must be enabled firstly. When a new board is inserted, and the power is over-load, a value of disconnection(0) means that the power will stop supply to the low priority slot ; A value of non-disconnection(1) means that the slot still supply when a new board is inserted, and the power is over-load too. | 1.3.6.1.4.1.2011.10.2.14.2.1.5 | INTEGER {disconnection(0), non-disconnection(1)} | read-write | current |
| h3cMainPseLegacy OBJECT-TYPE Describes or controls the legacy mode on slot which must be enabled firstly. Legacy mode: standard or nonstandard PD detection mode. | 1.3.6.1.4.1.2011.10.2.14.2.1.6 | INTEGER {enable(0), disable(1)} | read-write | current |
| h3cMainPsePowerPriority OBJECT-TYPE Describes or controls the priority of the PSE. The priority will be used by the PSE policy to prevent from power overloading. If the priority of PSE is set to critical, the PSE will turn into guaranteed mode. The priority could be used by a control mechanism that prevents power overloading by disconnecting PSEs with lower power priority. PSEs that connect devices critical to the application should be set to higher priority. | 1.3.6.1.4.1.2011.10.2.14.2.1.7 | INTEGER {critical(1), high(2), low(3)} | read-write | current |
| h3cPseAutoDetectActive OBJECT-TYPE The object specifies whether the device auto-detection feature is active. If this object is set to Active, and a known powered device is detected, then the port will automatically switch to Auto-Guaranteed mode. This is a stackwide object (ie. it is not referenced by group index). | 1.3.6.1.4.1.2011.10.2.14.3 | INTEGER {notSupported(1), disabled(2), enabled(3)} | read-write | current |
| h3cPseComformance OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.4 | |||
| h3cPseCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.4.1 | |||
| h3cPseGroup OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.4.2 | |||
| h3cPsePowerMaxValue OBJECT-TYPE The object specifies the max poe power for lanswitch. The value should between the power currently and the max power. | 1.3.6.1.4.1.2011.10.2.14.5 | Integer32 | read-write | current |
| h3cpseportNotification OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.6 | |||
| h3cPseProfilesTable OBJECT-TYPE A table of objects representing a set of power profiles. Power profiles can be applied to PoE ports, which have the effect of automatically setting the priority, power limit and PoE enable MIB objects to the values specified in the power profile. | 1.3.6.1.4.1.2011.10.2.14.7 | not-accessible | current | |
| h3cPseProfilesEntry OBJECT-TYPE A set of objects that display and control the Main power of a PSE. | 1.3.6.1.4.1.2011.10.2.14.7.1 | not-accessible | current | |
| h3cPseProfileIndex OBJECT-TYPE The index of the profile. This uniquely allow the profile to be identified. | 1.3.6.1.4.1.2011.10.2.14.7.1.1 | Integer32 (1..100) | not-accessible | current |
| h3cPseProfileName OBJECT-TYPE Assigns the profile a name with which the settings can be assiciated with. For example, 'NBX Phone'. | 1.3.6.1.4.1.2011.10.2.14.7.1.2 | DisplayString (SIZE(1..15)) | read-create | current |
| h3cPseProfilePowerMode OBJECT-TYPE The power mode associated with this power profile. There are two possible power modes as follows: powerDisabled, powerEnabled. When a power profile is applied to a PSE port, this value dictates the settings of the ports pethPsePortPowerPriority and pethPsePortAdminEnable objects. | 1.3.6.1.4.1.2011.10.2.14.7.1.3 | INTEGER {powerDisabled(1), powerEnabled(2)} | read-create | current |
| h3cPseProfilePowerLimit OBJECT-TYPE The power limit to be applied to the ports h3cPsePortPowerLimit object when the profile is applied to the PSE port. Expressed in milliWatts. | 1.3.6.1.4.1.2011.10.2.14.7.1.4 | Integer32 (0..15400) | read-create | current |
| h3cPseProfilePriority OBJECT-TYPE This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority. | 1.3.6.1.4.1.2011.10.2.14.7.1.5 | INTEGER {critical(1), high(2), low(3)} | read-create | current |
| h3cPseProfilePairs OBJECT-TYPE Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. | 1.3.6.1.4.1.2011.10.2.14.7.1.6 | INTEGER {signal(1), spare(2)} | read-create | current |
| h3cPseProfileApplyNum OBJECT-TYPE The number of this profile which has been applied. If h3cPseProfileApplyNum is not zero, user can't change the current line. | 1.3.6.1.4.1.2011.10.2.14.7.1.7 | Integer32 | read-only | current |
| h3cPseProfileRowStatus OBJECT-TYPE The status of this classifier. If h3cPseProfileApplyNum is not zero, user can't delete the current line. | 1.3.6.1.4.1.2011.10.2.14.7.1.8 | RowStatus | read-create | current |
| h3cPOEPowerObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8 | |||
| h3cPOEThresholdLimitObjs OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.1 | |||
| h3cPOEThresholdACMimimum OBJECT-TYPE Input threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. The value of this node should be smaller than 264.0V and larger than 90.0V. And it should be smaller than the h3cPOEThresholdACMaximum. | 1.3.6.1.4.1.2011.10.2.14.8.1.1 | OCTET STRING (SIZE(1..10)) | read-write | current |
| h3cPOEThresholdACMaximum OBJECT-TYPE Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the h3cPOEThresholdACMinimum. | 1.3.6.1.4.1.2011.10.2.14.8.1.2 | OCTET STRING (SIZE(1..10)) | read-write | current |
| h3cPOEThresholdDCMinimum OBJECT-TYPE Input threshold DC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 47.0V and larger than 45.0V. | 1.3.6.1.4.1.2011.10.2.14.8.1.3 | OCTET STRING (SIZE(1..10)) | read-write | current |
| h3cPOEThresholdDCMaximum OBJECT-TYPE Input threshold DC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 57.0V and larger than 55.0V. | 1.3.6.1.4.1.2011.10.2.14.8.1.4 | OCTET STRING (SIZE(1..10)) | read-write | current |
| h3cPOESupModuleInfoObjs OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.2 | |||
| h3cPOEPowerType OBJECT-TYPE The type of the power. | 1.3.6.1.4.1.2011.10.2.14.8.2.1 | OCTET STRING (SIZE(1..127)) | read-only | current |
| h3cPOEPowerModuleNum OBJECT-TYPE The number of the power modules. | 1.3.6.1.4.1.2011.10.2.14.8.2.2 | Integer32 | read-only | current |
| h3cPOESupervisionModuleName OBJECT-TYPE The object specifies the Supervision Module name on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.2.3 | OCTET STRING (SIZE(1..127)) | read-only | current |
| h3cPOESMMajorVersion OBJECT-TYPE The object specifies the high byte of the monitor module version. | 1.3.6.1.4.1.2011.10.2.14.8.2.4 | Integer32 | read-only | current |
| h3cPOESMMinorVersion OBJECT-TYPE The object specifies the low byte of the monitor module version. | 1.3.6.1.4.1.2011.10.2.14.8.2.5 | Integer32 | read-only | current |
| h3cPOESMFactorName OBJECT-TYPE The object specifies the name of the manufactor. | 1.3.6.1.4.1.2011.10.2.14.8.2.6 | OCTET STRING (SIZE(1..127)) | read-only | current |
| h3cPOEModuleInfoTable OBJECT-TYPE The table of the module information on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.2.7 | not-accessible | current | |
| h3cPOEModuleInfoEntry OBJECT-TYPE The entry of the module information on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1 | not-accessible | current | |
| h3cPOEModuleIndex OBJECT-TYPE The index of the current module on this POE power. It is also the index of h3cPOEModuleInfoTable. The range of this node is from 1 to h3cPOEPowerModuleNum. | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.1 | Integer32 (1..2147483647) | accessible-for-notify | current |
| h3cPOEModuleID OBJECT-TYPE The ID of the current module on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.2 | Integer32 | read-only | current |
| h3cPOEModuleInfoPower OBJECT-TYPE The power of the current module on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.3 | Integer32 | read-only | current |
| h3cPOEModuleHardVerInfo OBJECT-TYPE The hardware version information of the current module on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.4 | OCTET STRING (SIZE(1..127)) | read-only | current |
| h3cPOEDCOutStateObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.3 | |||
| h3cPOEDCOutStateModuleNum OBJECT-TYPE The module number on this POE power. It is the maximum of the h3cPOEDCOutStateIndex. | 1.3.6.1.4.1.2011.10.2.14.8.3.1 | Integer32 | read-only | current |
| h3cPOEDCOutStateTable OBJECT-TYPE The table of DC output power state on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.3.2 | not-accessible | current | |
| h3cPOEDCOutStateEntry OBJECT-TYPE The entry of the DC output power state on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.3.2.1 | not-accessible | current | |
| h3cPOEDCOutStateIndex OBJECT-TYPE The index of the DC output power state on this POE power. The range of this node is from 1 to h3cPOEDCOutStateModuleNum. | 1.3.6.1.4.1.2011.10.2.14.8.3.2.1.1 | Integer32 (1..2147483647) | accessible-for-notify | current |
| h3cPOEDCOutDCVolAlarm OBJECT-TYPE The DC output alarm of the DC output power state on this POE power. The value of this node will be the following values: normal (1), underLimit (2), aboveLimit (3), fuseBroken (4), switchOff (5), otherError (6). | 1.3.6.1.4.1.2011.10.2.14.8.3.2.1.2 | DCAlarmState | read-only | current |
| h3cPOEDCOutInfoObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.4 | |||
| h3cPOEDCOutCurNum OBJECT-TYPE The number of DC output current on this POE power. It is the maximum of h3cPOEDCOutInfoIndex. | 1.3.6.1.4.1.2011.10.2.14.8.4.1 | Integer32 | read-only | current |
| h3cPOEDCOutInfoTable OBJECT-TYPE The table of the DC output information on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.4.2 | not-accessible | current | |
| h3cPOEDCOutInfoEntry OBJECT-TYPE The entry of the DC output information on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1 | not-accessible | current | |
| h3cPOEDCOutInfoIndex OBJECT-TYPE The index of the DC output information on this POE POWER. The range of this node is from 1 to h3cPOEDCOutCurNum. | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1.1 | Integer32 (1..2147483647) | accessible-for-notify | current |
| h3cPOEDCOutVol OBJECT-TYPE The DC output voltage of the current DC output on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1.2 | OCTET STRING (SIZE(1..10)) | read-only | current |
| h3cPOEDCOutInfoLoadCur OBJECT-TYPE The total load current of the current DC output on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1.3 | OCTET STRING (SIZE(1..10)) | read-only | current |
| h3cPOEACSwitchStateModuleObjs OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.5 | |||
| h3cPOEACSwitchStateModuleNum OBJECT-TYPE The number of the AC swtich state module on this POE power. It is the maximum of h3cPOEACSwitchStateIndex. | 1.3.6.1.4.1.2011.10.2.14.8.5.1 | Integer32 | read-only | current |
| h3cPOEACSwitchStateTable OBJECT-TYPE The table of the AC switch state on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.5.2 | not-accessible | current | |
| h3cPOEACSwitchStateEntry OBJECT-TYPE The entry of the AC switch state on this POE power. | 1.3.6.1.4.1.2011.10.2.14.8.5.2.1 | not-accessible | current | |
| h3cPOEACSwitchStateIndex OBJECT-TYPE The index of the AC switch state on this POE power. The range of this node is from 1 to h3cPOEACSwitchStateModuleNum. | 1.3.6.1.4.1.2011.10.2.14.8.5.2.1.1 | Integer32 (1..2147483647) | accessible-for-notify | current |
| h3cPOEACSwitchState OBJECT-TYPE The AC switch state on this POE power. The value of this node will be one of the following values: on (1), off (2), highVoltInput (3), lowVoltInput (4) | 1.3.6.1.4.1.2011.10.2.14.8.5.2.1.2 | SwitchState | read-only | current |
| h3cPOEInCurStateObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.6 | |||
| h3cPOEInCurStateModuleNum OBJECT-TYPE The DC input current state of the module on this POE power. It is the maximum of the h3cPOESwitchStateVolExIndex. | 1.3.6.1.4.1.2011.10.2.14.8.6.1 | Integer32 | read-only | current |
| h3cPOEInCurAState OBJECT-TYPE The current A state in the DC input on this POE power. normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.2 | ACAlarmState | read-only | current |
| h3cPOEInCurBState OBJECT-TYPE The current B state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.3 | ACAlarmState | read-only | current |
| h3cPOEInCurCState OBJECT-TYPE The current C state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.4 | ACAlarmState | read-only | current |
| h3cPOESwitchStateVolExTable OBJECT-TYPE All alarm status of the VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.5 | not-accessible | current | |
| h3cPOESwitchStateVolExEntry OBJECT-TYPE The h3cPOESwitchStateVolExIndex will match the number of the VOL status. | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1 | not-accessible | current | |
| h3cPOESwitchStateVolExIndex OBJECT-TYPE The object species the index of the VOL status. The range of this node is from 1 to h3cPOEInCurStateModuleNum. | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.1 | Integer32 (1..2147483647) | accessible-for-notify | current |
| h3cPOESwitchStateInVolAB OBJECT-TYPE The object specifies the VOL AB alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.2 | ACAlarmState | read-only | current |
| h3cPOESwitchStateInVolBC OBJECT-TYPE The object specifies the VOL BC alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.3 | ACAlarmState | read-only | current |
| h3cPOESwitchStateInVolCA OBJECT-TYPE The object specifies the VOL CA alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.4 | ACAlarmState | read-only | current |
| h3cPOEAlarmStateObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2011.10.2.14.8.7 | |||
| h3cPOEAlarmStateModuleNum OBJECT-TYPE The object specifies the number of the power modules in alarm state. | 1.3.6.1.4.1.2011.10.2.14.8.7.1 | Integer32 | read-only | current |
| h3cPOEAlarmStateInfoTable OBJECT-TYPE All alarm states in the POE power modules. | 1.3.6.1.4.1.2011.10.2.14.8.7.2 | not-accessible | current | |
| h3cPOEAlarmStateInfoEntry OBJECT-TYPE The h3cPOEAlarmModuleInfoIndex will match the number of the power module. | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1 | not-accessible | current | |
| h3cPOEAlarmModuleInfoIndex OBJECT-TYPE The index specifies the index of the H3cPOEAlarmStateInfoEntry table. The range of this node is from 1 to h3cPOEAlarmStateModuleNum. | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.1 | Integer32 (1..2147483647) | accessible-for-notify | current |
| h3cPOEModuleDisconnect OBJECT-TYPE The node specifies the alarm state: The module does not link. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.2 | ModuleAlarmState | read-only | current |
| h3cPOEModuleInputError OBJECT-TYPE The node specifies the alarm state: Input error. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.3 | ModuleAlarmState | read-only | current |
| h3cPOEModuleOutputError OBJECT-TYPE The node specifies the alarm state: Output error. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.4 | ModuleAlarmState | read-only | current |
| h3cPOEModuleOverVoltage OBJECT-TYPE The node specifies the alarm state: The voltage is too high. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.5 | ModuleAlarmState | read-only | current |
| h3cPOEModuleOverTemp OBJECT-TYPE The node specifies the alarm state: The temperature is too high. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.6 | ModuleAlarmState | read-only | current |
| h3cPOEModuleFanError OBJECT-TYPE The node specifies the alarm state: The fan error. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.7 | ModuleAlarmState | read-only | current |
| h3cPOEModuleShutdown OBJECT-TYPE The node specifies the alarm state: The module is shutdown. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.8 | ModuleAlarmState | read-only | current |
| h3cPOEModuleCurRestricted OBJECT-TYPE The node specifies the alarm state: The module limit the current. The value of this node is one of the following values: normal (1), alarm (2). | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.9 | ModuleAlarmState | read-only | current |
| h3cPsePolicyMode OBJECT-TYPE The PSE policy only applies to the situation that when a new board (PSE) is inserted, and the power is overload. A value of priority(2) means that the power will stop supplying to the low priority PSE. About PSE priority, please refer to h3cMainPsePowerPriority. A value of disabled(1) means that the power will stop supplying to the new inserted PSE. The default value of this object is disabled(1). | 1.3.6.1.4.1.2011.10.2.14.9 | INTEGER {disabled(1), priority(2)} | read-write | current |
| h3cPDPolicyMode OBJECT-TYPE The PD policy only applies to the situation that when a new PD is inserted, and the power of PSE is overload. A value of priority(2) means that the power will stop supplying to the low priority port PD. About port priority, please refer to pethPsePortPowerPriority. A value of disabled(1) means that the slot stop supplying to the new inserted PD. The default value of this object is disabled(1). | 1.3.6.1.4.1.2011.10.2.14.10 | INTEGER {disabled(1), priority(2)} | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| h3cpsePDChangeNotification NOTIFICATION-TYPE This notification indicates if PD has been inserted or pulled out. | 1.3.6.1.4.1.2011.10.2.14.6.1 | current |
| h3cPOEDisconnectNotification NOTIFICATION-TYPE This notification indicates the POE power module does not disconnect. | 1.3.6.1.4.1.2011.10.2.14.6.2 | current |
| h3cPOEInputErrorNotification NOTIFICATION-TYPE This notification indicates the POE power module input error. | 1.3.6.1.4.1.2011.10.2.14.6.3 | current |
| h3cPOEOutputErrorNotification NOTIFICATION-TYPE This notification indicates the POE power module output error. | 1.3.6.1.4.1.2011.10.2.14.6.4 | current |
| h3cPOEOverVoltageNotification NOTIFICATION-TYPE This notification indicates the POE power module overruns the voltage limit. | 1.3.6.1.4.1.2011.10.2.14.6.5 | current |
| h3cPOEOverTempNotification NOTIFICATION-TYPE This notification indicates the POE power module overruns the temperature limit. | 1.3.6.1.4.1.2011.10.2.14.6.6 | current |
| h3cPOEFanErrorNotification NOTIFICATION-TYPE This notification indicates the POE power module fan error. | 1.3.6.1.4.1.2011.10.2.14.6.7 | current |
| h3cPOEModuleShutdownNotification NOTIFICATION-TYPE This notification indicates the POE power module is closed. | 1.3.6.1.4.1.2011.10.2.14.6.8 | current |
| h3cPOECurRestrictedNotification NOTIFICATION-TYPE This notification indicates the POE power module current is restricted. | 1.3.6.1.4.1.2011.10.2.14.6.9 | current |
| h3cPOEACSwitchNotification NOTIFICATION-TYPE This notification indicates the AC input switch alarm of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.10 | current |
| h3cPOEACInCurANotification NOTIFICATION-TYPE This notification indicates the AC input current A alarm state of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.11 | current |
| h3cPOEACInCurBNotification NOTIFICATION-TYPE This notification indicates the AC input current B alarm state of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.12 | current |
| h3cPOEACInCurCNotification NOTIFICATION-TYPE This notification indicates the AC input current C alarm state of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.13 | current |
| h3cPOEACSwitchVolABNotification NOTIFICATION-TYPE This notification indicates the AC input voltage AB alarm state of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.14 | current |
| h3cPOEACSwitchVolBCNotification NOTIFICATION-TYPE This notification indicates the AC input voltage BC alarm state of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.15 | current |
| h3cPOEACSwitchVolCANotification NOTIFICATION-TYPE This notification indicates the AC input voltage CA alarm state of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.16 | current |
| h3cPOEDCOutVolNotification NOTIFICATION-TYPE This notification indicates the DC output alarm of this POE power. | 1.3.6.1.4.1.2011.10.2.14.6.17 | current |
| h3cPOEShutdownNotification NOTIFICATION-TYPE This notification indicates the whole POE power has been shutdown. | 1.3.6.1.4.1.2011.10.2.14.6.18 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| h3cPseCompliance MODULE-COMPLIANCE Description. | 1.3.6.1.4.1.2011.10.2.14.4.1.1 | current |
| h3cPsePortGroup OBJECT-GROUP A collection of objects should be supported at the same time. | 1.3.6.1.4.1.2011.10.2.14.4.2.1 | current |
| h3cMainPseGroup OBJECT-GROUP A collection of objects should be supported at the same time. | 1.3.6.1.4.1.2011.10.2.14.4.2.2 | current |
| h3cPseScalarGroup OBJECT-GROUP A collection of scalar objects supported. | 1.3.6.1.4.1.2011.10.2.14.4.2.3 | current |
| h3cPsePDNotificationGroup OBJECT-GROUP PD Change Notification. | 1.3.6.1.4.1.2011.10.2.14.4.2.4 | current |
| h3cPseProfilesGroup OBJECT-GROUP A collection of objects should be supported at the same time. | 1.3.6.1.4.1.2011.10.2.14.4.2.5 | current |
| h3cPOEPowerThresholdLimitGroup OBJECT-GROUP Power threshold limits group. | 1.3.6.1.4.1.2011.10.2.14.4.2.6 | current |
| h3cPOEPowerSupInfoGroup OBJECT-GROUP The basic Power information group. | 1.3.6.1.4.1.2011.10.2.14.4.2.7 | current |
| h3cPOEPowerDCOutStateGroup OBJECT-GROUP The DC out power state group. | 1.3.6.1.4.1.2011.10.2.14.4.2.8 | current |
| h3cPOEPowerDCOutInfoGroup OBJECT-GROUP The power AC input switch information group | 1.3.6.1.4.1.2011.10.2.14.4.2.9 | current |
| h3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP PD Change Notification. | 1.3.6.1.4.1.2011.10.2.14.4.2.10 | current |
| h3cPOEPowerInCurStateGroup OBJECT-GROUP PD Change Notification. | 1.3.6.1.4.1.2011.10.2.14.4.2.11 | current |
| h3cPOEPowerAlarmStateGroup OBJECT-GROUP PD Change Notification. | 1.3.6.1.4.1.2011.10.2.14.4.2.12 | current |