MIBs Depot

H3C-MPLSOAM-PS-MIB

Registered at
1.3.6.1.4.1.2011.10.2.80
Last updated
2007-03-31 00:00
Organization
Huawei 3Com Technologies Co., Ltd.
Namespace
huawei
Source file
H3C-MPLSOAM-PS-MIB
Digest
sha256:29c2791f5dbe5d87d8c6c5f43a30e692a726af7bf939ae3c8fe2a990ae8c1a19

Description

This MIB contains objects to configure mpls protect-switch module.

Contact

Platform Team Huawei 3Com Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.huawei-3com.com Zip:100085

Imports

FromSymbols
HUAWEI-3COM-OID-MIBh3cCommon
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

H3C-MPLSOAM-PS-MIB
HUAWEI-3COM-OID-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
h3cMplsOamPsScalarGroup
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.2.80.1
h3cMplsOamPsTrapOpen
OBJECT-TYPE
Whether mpls protect-switch trap is globally enabled. false: disable; true: enable
1.3.6.1.4.1.2011.10.2.80.1.1TruthValueread-writecurrent
h3cMplsOamPsTable
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.2.80.2
h3cMplsPsTable
OBJECT-TYPE
This table specifies per-protection-group MPLS PS capability and associated information.
1.3.6.1.4.1.2011.10.2.80.2.1not-accessiblecurrent
h3cMplsPsEntry
OBJECT-TYPE
An entry in this table is created by an LSR for every protection group capable of supporting mpls ps.
1.3.6.1.4.1.2011.10.2.80.2.1.1not-accessiblecurrent
h3cMplsPsIndex
OBJECT-TYPE
This is a unique index for an entry in the mplspsEntry.
1.3.6.1.4.1.2011.10.2.80.2.1.1.1Integer32not-accessiblecurrent
h3cMplsPsGroupID
OBJECT-TYPE
This is a unique group id for an entry in the mplspsEntry. One protect-switch group is composed of one working static-lsp and one protection static-lsp.
1.3.6.1.4.1.2011.10.2.80.2.1.1.2Integer32read-createcurrent
h3cMplsPsWorkLspName
OBJECT-TYPE
The name of the working static-lsp.
1.3.6.1.4.1.2011.10.2.80.2.1.1.3OCTET STRINGread-createcurrent
h3cMplsPsProtectLspName
OBJECT-TYPE
The name of the protection static-lsp.
1.3.6.1.4.1.2011.10.2.80.2.1.1.4OCTET STRINGread-createcurrent
h3cMplsPsRevertiveMode
OBJECT-TYPE
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired. And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
1.3.6.1.4.1.2011.10.2.80.2.1.1.5Integer32 (1..2)read-createcurrent
h3cMplsPsWTR
OBJECT-TYPE
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP, it prevents reversion back to select the working LSP until the Wait to Restore timer has expired. The default value is 12 minutes. step is 30s.
1.3.6.1.4.1.2011.10.2.80.2.1.1.6Integer32read-createcurrent
h3cMplsPsHoldOff
OBJECT-TYPE
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. Step is 100ms, maximum is 10s.
1.3.6.1.4.1.2011.10.2.80.2.1.1.7Integer32read-createcurrent
h3cMplsPsSwitchCondition
OBJECT-TYPE
The current switch condition of the protection group. 1: clear, this command clears all of the externally initiated switch commands listed below; 2: lockout of protection, fix the selector position on the working LSP, Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection, switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail, for 1:1, Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp, switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp, switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer, a configurable timer which is used to delay before reversion; 8: HoldOff-timer, the time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp
1.3.6.1.4.1.2011.10.2.80.2.1.1.8Integer32 (1..9)read-createcurrent
h3cMplsPsWorkLspDetectState
OBJECT-TYPE
The state of working static-lsp state in one protection group, whether it is in defect: 1: it is out of defect; 2: it enters defect.
1.3.6.1.4.1.2011.10.2.80.2.1.1.9Integer32 (1..2)read-onlycurrent
h3cMplsPsWorkLspUpDownState
OBJECT-TYPE
The state of working static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state.
1.3.6.1.4.1.2011.10.2.80.2.1.1.10Integer32 (1..2)read-onlycurrent
h3cMplsPsProtLspDetectState
OBJECT-TYPE
The state of protection static-lsp state in one protection group, whether it is in detection: 1: it is out of defect; 2: it enters defect.
1.3.6.1.4.1.2011.10.2.80.2.1.1.11Integer32 (1..2)read-onlycurrent
h3cMplsPsProtLspUpDownState
OBJECT-TYPE
The state of protection static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state.
1.3.6.1.4.1.2011.10.2.80.2.1.1.12Integer32 (1..2)read-onlycurrent
h3cMplsPsSwitchResult
OBJECT-TYPE
Which tunnel is used to transfer the data stream. 1: working static-lsp; 2: protection static-lsp.
1.3.6.1.4.1.2011.10.2.80.2.1.1.13Integer32 (1..2)read-onlycurrent
h3cMplsPsRowStatus
OBJECT-TYPE
This object is responsible for managing the creation, deletion and modification of rows, which support active status and CreatAndGo, destroy operation. To create a new row, h3cMplsPsGroupID, h3cMplsPsWorkLspName, h3cMplsPsProtectLspName, h3cMplsPsRevertiveMode, h3cMplsPsWTR and h3cMplsPsHoldOff must be specified.
1.3.6.1.4.1.2011.10.2.80.2.1.1.14RowStatusread-createcurrent
h3cMplsOamPsNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.2011.10.2.80.3

Notifications

NameOIDStatus
h3cMplsPsSwitchPtoW
NOTIFICATION-TYPE
This notification is generated when switching from protection-lsp to working-lsp occured.
1.3.6.1.4.1.2011.10.2.80.3.1current
h3cMplsPsSwitchWtoP
NOTIFICATION-TYPE
This notification is generated when switching from woking-lsp to protection-lsp occured.
1.3.6.1.4.1.2011.10.2.80.3.2current