GUDEADS-EPC24X-MIB
- Registered at
- 1.3.6.1.4.1.28507.5
- Last updated
- 2007-03-05 13:56
- Organization
- Gude Analog- und Digitalsysteme GmbH
- Revisions
- 2007-03-05 13:56
- Namespace
- gude
- Source file
GUDEADS-EPC24X-MIB- Digest
sha256:659380041be0d2fa95c5f29fce90bb0a41554b4cc21571160974e880425dd371
Contact
http://www.gudeads.com/
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
GUDEADS-EPC24X-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| gadsEPC24 OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5 | |||
| epc24Objects OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5.1 | |||
| epc24powerports OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5.1.1 | |||
| epc24portNumber OBJECT-TYPE The number of PowerPorts | 1.3.6.1.4.1.28507.5.1.1.1 | Integer32 (1..24) | read-only | current |
| epc24portTable OBJECT-TYPE list of all EPC Powerports | 1.3.6.1.4.1.28507.5.1.1.2 | not-accessible | current | |
| epc24portEntry OBJECT-TYPE An entry containing management information applicable to a particular powerport. | 1.3.6.1.4.1.28507.5.1.1.2.1 | not-accessible | current | |
| epc24PortIndex OBJECT-TYPE A unique value, greater than zero, for each PowerPort. | 1.3.6.1.4.1.28507.5.1.1.2.1.1 | Integer32 (1..24) | not-accessible | current |
| epc24PortName OBJECT-TYPE A textual string containing name of a PowerPort. | 1.3.6.1.4.1.28507.5.1.1.2.1.2 | OCTET STRING (SIZE(0..15)) | read-only | current |
| epc24PortState OBJECT-TYPE current state a PowerPort | 1.3.6.1.4.1.28507.5.1.1.2.1.3 | INTEGER {off(0), on(1)} | read-write | current |
| epc24PortSwitchCount OBJECT-TYPE The total number of switch actions ocurred on a PowerPort. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here. | 1.3.6.1.4.1.28507.5.1.1.2.1.4 | Counter32 | read-only | current |
| epc24Fuse1 OBJECT-TYPE State of Fuse1 (1 = ok) | 1.3.6.1.4.1.28507.5.1.1.3 | Integer32 (0..1) | read-only | current |
| epc24Fuse2 OBJECT-TYPE State of Fuse2 (1 = ok) | 1.3.6.1.4.1.28507.5.1.1.4 | Integer32 (0..1) | read-only | current |
| epc24Fuse3 OBJECT-TYPE State of Fuse3 (1 = ok) | 1.3.6.1.4.1.28507.5.1.1.5 | Integer32 (0..1) | read-only | current |
| epc24Events OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5.2 | |||
| epc24Conf OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5.3 | |||
| epc24Groups OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5.3.1 | |||
| epc24Compls OBJECT-IDENTITY | 1.3.6.1.4.1.28507.5.3.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| epc24BasicGroup OBJECT-GROUP Basic objects. | 1.3.6.1.4.1.28507.5.3.1.1 | current |