GIGAMON-SNMP-MIB
- Registered at
- 1.3.6.1.4.1.26866
- Last updated
- 2018-05-15 00:00
- Organization
- www.gigamon.com
- Revisions
- 2018-05-15 00:00, 2013-09-25 00:00, 2013-04-15 00:00, 2012-12-04 00:00, 2012-05-09 00:00, 2012-03-27 00:00, 2011-03-25 00:00, 2011-03-24 00:00, 2011-03-03 00:00, 2010-07-10 10:00
- Namespace
- gigamon
- Source file
GIGAMON-SNMP-MIB- Digest
sha256:cbf07eb083bf13f5afa9f687b52bfc98c761c3398f93f62877ce78d16e944bac
Description
Top-level infrastructure of Gigamon's MIB objects for GigaVUE-212, GigaVUE-420, GigaVUE-2404, GigaVUE-HD and GigaVUE-TA1
Contact
postal: Gigamon LLC 598 Gibraltar Drive Milpitas, CA 95035 email: support@gigamon.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-MIB | sysLocation |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
GIGAMON-SNMP-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| gigamonSnmpNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.26866.1 | |||
| gigamonGigaVUE OBJECT-IDENTITY | 1.3.6.1.4.1.26866.1.1 | |||
| gigamonSnmpNotificationObjects OBJECT-IDENTITY | 1.3.6.1.4.1.26866.1.2 | |||
| gigamonSnmpNotifLevel OBJECT-TYPE It acts as a payload for the level of Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.1 | INTEGER {information(1), minor(2), major(3), critical(4)} | accessible-for-notify | current |
| gigamonSnmpNotifDescription OBJECT-TYPE It acts as a payload for the description of Gigamon's Notifications. The value is to describe the reason for the notification. | 1.3.6.1.4.1.26866.1.2.2 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpNotifOpType OBJECT-TYPE It specifies the type of operation of Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.3 | INTEGER {read(1), write(2), delete(3), validate(4), change(5)} | accessible-for-notify | current |
| gigamonSnmpNotifPortName OBJECT-TYPE The alpha-numerical name of a port shown in Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.4 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpNotifPortLinkStatus OBJECT-TYPE It indicates port link status of Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.5 | INTEGER {down(0), up(1)} | accessible-for-notify | current |
| gigamonSnmpNotifTAPRelayStatus OBJECT-TYPE It indicates TAP relay status of Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.6 | INTEGER {none(0), passive(1), active(2)} | accessible-for-notify | current |
| gigamonSnmpNotifRxTxType OBJECT-TYPE It indicates Incoming/RX or outgoing/TX packets | 1.3.6.1.4.1.26866.1.2.7 | INTEGER {rx(0), tx(1)} | accessible-for-notify | current |
| gigamonSnmpNotifRxTxErrorType OBJECT-TYPE It indicates RX/TX error type of Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.8 | INTEGER {under-size(0), fragments(1), obsolete(2), jabbers(3), crc-align(4), unknown(5)} | accessible-for-notify | current |
| gigamonSnmpNotifCounter OBJECT-TYPE 32-bit Counter. | 1.3.6.1.4.1.26866.1.2.9 | INTEGER | accessible-for-notify | current |
| gigamonSnmpNotifFirmwareName OBJECT-TYPE Name of GigaVUE firmware. | 1.3.6.1.4.1.26866.1.2.10 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpNotifModuleOperationType OBJECT-TYPE It indicates the operation performed on module | 1.3.6.1.4.1.26866.1.2.11 | INTEGER {removed(0), inserted(1), changed(2), mismatch(3), shutdown(4), up(5), license-mismatch(6)} | accessible-for-notify | current |
| gigamonSnmpNotifModuleName OBJECT-TYPE Module name of GigaVUE module | 1.3.6.1.4.1.26866.1.2.12 | OCTET STRING | accessible-for-notify | current |
| gigamonNotifSlotNumber OBJECT-TYPE Slot number | 1.3.6.1.4.1.26866.1.2.13 | INTEGER {mid-plane(0), slot-1(1), slot-2(2), slot-3(3), gigaLink-Back(4), daughter-Card(5), slot-4(10), slot-5(11), slot-6(12), slot-7(13), slot-8(14), slot-CC1(15), slot-CC2(16)} | accessible-for-notify | current |
| gigamonSnmpNotifUserName OBJECT-TYPE User login name typed in | 1.3.6.1.4.1.26866.1.2.14 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpNotifFileName OBJECT-TYPE Saved configuration file name | 1.3.6.1.4.1.26866.1.2.15 | OCTET STRING | accessible-for-notify | current |
| gigamonNotifPowerStatus OBJECT-TYPE Power Status | 1.3.6.1.4.1.26866.1.2.16 | INTEGER {failure(-1), abnormal(0), normal(1)} | accessible-for-notify | current |
| gigamonSnmpNotifHardWareName OBJECT-TYPE Description of Hardware | 1.3.6.1.4.1.26866.1.2.17 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpNotifGigaVUE420SlotNumber OBJECT-TYPE Slot number | 1.3.6.1.4.1.26866.1.2.18 | INTEGER {mid-plane(0), expansion-slot-1(1), expansion-slot-2(2), expansion-slot-3(3), expansion-slot-4(4), expansion-slot-5(5), x1-slot(6), x2-slot(7), x3-slot(8), x4-slot(9)} | accessible-for-notify | current |
| gigamonSnmpNotifFanName OBJECT-TYPE Name of fan | 1.3.6.1.4.1.26866.1.2.19 | OCTET STRING | accessible-for-notify | current |
| gigamonNotifFanStatus OBJECT-TYPE Fan Status | 1.3.6.1.4.1.26866.1.2.20 | INTEGER {failure(-1), abnormal(0), normal(1)} | accessible-for-notify | current |
| gigamonSnmpNotifUtilizationAlarm OBJECT-TYPE It indicates over-threshold port utilization alarm of Gigamon's Notifications. | 1.3.6.1.4.1.26866.1.2.21 | INTEGER {below(0), exceed(1)} | accessible-for-notify | current |
| gigamonSnmpNotifUtilizationThreshold OBJECT-TYPE Utilization threshold percentage | 1.3.6.1.4.1.26866.1.2.22 | INTEGER | accessible-for-notify | current |
| gigamonSnmpBatteryLevel OBJECT-TYPE battery level: 0 - battery charge complete 1 - battery level has been down below 75% 2 - battery level has been down below 50% 3 - battery level has been down below 25% 4 - battery level has down to 15% or below and shutting down the system | 1.3.6.1.4.1.26866.1.2.23 | INTEGER {batteryChargeComplete(0), downBelow75(1), downBelow50(2), downBelow25(3), shutDownSystem(4)} | read-only | current |
| gigamonSnmpPortLinkSpeed OBJECT-TYPE port link speed: 0 - Not Apply if link is down 1 - 10 Mbps 2 - 100 Mbps 3 - 1000 Mbps 4 - 10000 Mbps 5 - 40000 Mbps 6 - 100000 Mbps | 1.3.6.1.4.1.26866.1.2.24 | INTEGER {notApply(0), speed10(1), speed100(2), speed1000(3), speed10000(4), speed40000(5), speed100000(6)} | accessible-for-notify | current |
| gigamonSnmpPortLinkDuplex OBJECT-TYPE port link duplex: 0 - Not Apply if link is down 1 - full duplex 2 - half duplex | 1.3.6.1.4.1.26866.1.2.25 | INTEGER {notApply(0), full(1), half(2)} | accessible-for-notify | current |
| gigamonSnmpNotifCpuIndex OBJECT-TYPE Index of CPU, starting from 0 | 1.3.6.1.4.1.26866.1.2.26 | Unsigned32 | accessible-for-notify | current |
| gigamonSnmpNotifFsMountPoint OBJECT-TYPE Mount point for this filesystem | 1.3.6.1.4.1.26866.1.2.27 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpPowerSource OBJECT-TYPE power source: 0 - main power 1 - poe(Power over Ethernet) 2 - -48V Power | 1.3.6.1.4.1.26866.1.2.28 | INTEGER {mainPower(0), poe(1), power48V(2)} | read-only | current |
| gigamonSnmpNotifBpsUnitName OBJECT-TYPE Name of BPS unit | 1.3.6.1.4.1.26866.1.2.29 | OCTET STRING | accessible-for-notify | current |
| gigamonSnmpNotifBpsFailoverStatus OBJECT-TYPE Inline-bypass active unit change | 1.3.6.1.4.1.26866.1.2.30 | INTEGER {primary(0), secondary(1)} | accessible-for-notify | current |
| gigamonSystem OBJECT-IDENTITY | 1.3.6.1.4.1.26866.2 | |||
| manufacturer OBJECT-TYPE Displays the manufacturer name of the system. | 1.3.6.1.4.1.26866.2.1 | OCTET STRING | read-only | current |
| model OBJECT-TYPE Displays the model name of the system. | 1.3.6.1.4.1.26866.2.2 | OCTET STRING | read-only | current |
| name OBJECT-TYPE Displays the name of the system. | 1.3.6.1.4.1.26866.2.3 | OCTET STRING | read-only | current |
| serialNumber OBJECT-TYPE Displays the serial number of the system. | 1.3.6.1.4.1.26866.2.4 | OCTET STRING | read-only | current |
| systemDescription OBJECT-TYPE Displays the description of the system. | 1.3.6.1.4.1.26866.2.5 | OCTET STRING | read-only | current |
| version OBJECT-TYPE Displays the software version of the system. | 1.3.6.1.4.1.26866.2.6 | OCTET STRING | read-only | current |
| chassisModelNumber OBJECT-TYPE Displays the chassis model number of the system. | 1.3.6.1.4.1.26866.2.7 | OCTET STRING | read-only | current |
| chassisSerialNumber OBJECT-TYPE Displays the chassis serial number of the system. | 1.3.6.1.4.1.26866.2.8 | OCTET STRING | read-only | current |
| bladeSerialNumbers OBJECT-TYPE Displays the blade serial numbers in the system. | 1.3.6.1.4.1.26866.2.9 | OCTET STRING | read-only | current |
| firmwareVersion OBJECT-TYPE Displays the firmware version of the system. | 1.3.6.1.4.1.26866.2.10 | OCTET STRING | read-only | current |
| hardwareVersion OBJECT-TYPE Displays the hardware version of the system. | 1.3.6.1.4.1.26866.2.11 | OCTET STRING | read-only | current |
| cpuRAMSize OBJECT-TYPE Displays the CPU RAM size of the system. | 1.3.6.1.4.1.26866.2.12 | OCTET STRING | read-only | current |
| cpuUtilization OBJECT-TYPE Displays the CPU utilization of the system. | 1.3.6.1.4.1.26866.2.13 | OCTET STRING | read-only | current |
| fans OBJECT-TYPE Displays the fans in the system. | 1.3.6.1.4.1.26866.2.14 | OCTET STRING | read-only | current |
| temperatureSensors OBJECT-TYPE Displays the temperature sensors in the system. | 1.3.6.1.4.1.26866.2.15 | OCTET STRING | read-only | current |
| powerSupply OBJECT-TYPE Displays the power supplies in the system. | 1.3.6.1.4.1.26866.2.16 | OCTET STRING | read-only | current |
| gigamonProducts OBJECT-IDENTITY | 1.3.6.1.4.1.26866.3 | |||
| gigamonGV2404 OBJECT-IDENTITY | 1.3.6.1.4.1.26866.3.1 | |||
| gigamonGV420 OBJECT-IDENTITY | 1.3.6.1.4.1.26866.3.2 | |||
| gigamonGV212 OBJECT-IDENTITY | 1.3.6.1.4.1.26866.3.3 | |||
| gigamonGV216 OBJECT-IDENTITY | 1.3.6.1.4.1.26866.3.4 |
Notifications
| Name | OID | Status |
|---|---|---|
| gigamonSnmpResetSystemNotification NOTIFICATION-TYPE System reset notification triggered by cold or warm start. | 1.3.6.1.4.1.26866.1.1.1 | current |
| gigamonSnmpUserAuthFailNotification NOTIFICATION-TYPE Failure in user login operation is the triggered Event. | 1.3.6.1.4.1.26866.1.1.2 | current |
| gigamonSnmpFirmwareChangeNotification NOTIFICATION-TYPE Firmware Change notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.3 | current |
| gigamonSnmpConfigSaveNotification NOTIFICATION-TYPE Config save notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.4 | current |
| gigamonSnmpModuleChangeNotification NOTIFICATION-TYPE GigaVUE HW module swapping is the triggered Event. | 1.3.6.1.4.1.26866.1.1.5 | current |
| gigamonSnmpPacketDropNotification NOTIFICATION-TYPE Packet Drop notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.6 | current |
| gigamonSnmpTapRelayChangeNotification NOTIFICATION-TYPE TAP relay change notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.7 | current |
| gigamonSnmpPortLinkChangeNotification NOTIFICATION-TYPE Port link status change notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.8 | current |
| gigamonSnmpRxTxErrorNotification NOTIFICATION-TYPE Packet receive/transmit error notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.9 | current |
| gigamonPowerChangeNotification NOTIFICATION-TYPE Power supply status change notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.10 | current |
| gigamonFanChangeNotification NOTIFICATION-TYPE Fan status change notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.11 | current |
| gigamonSnmpOverThresholdChangeNotification NOTIFICATION-TYPE Utilization alarm notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.12 | current |
| gigamonSnmpBatteryLevelChangeNotification NOTIFICATION-TYPE Battery level down notification. | 1.3.6.1.4.1.26866.1.1.13 | current |
| gigamonLinkSpeedStatusChangeNotification NOTIFICATION-TYPE Link status or speed change notification. | 1.3.6.1.4.1.26866.1.1.14 | current |
| gigamonPowerSourceChangeNotification NOTIFICATION-TYPE Power source or status change notification. | 1.3.6.1.4.1.26866.1.1.15 | current |
| gigamonSnmpCpuUtilHighNotification NOTIFICATION-TYPE The average CPU utilization in the past minute has gone above the acceptable threshold | 1.3.6.1.4.1.26866.1.1.16 | current |
| gigamonSnmpUnexpectedShutdownNotification NOTIFICATION-TYPE The system has shut down unexpectedly | 1.3.6.1.4.1.26866.1.1.17 | current |
| gigamonSnmpDiskSpaceLowNotification NOTIFICATION-TYPE Free space in one of the filesystems is low | 1.3.6.1.4.1.26866.1.1.18 | current |
| gigamonSnmpWatchdogResetNotification NOTIFICATION-TYPE System reset notification triggered by watchdog timer. | 1.3.6.1.4.1.26866.1.1.19 | current |
| gigamonSnmpBpsFailoverNotification NOTIFICATION-TYPE Inline-bypass active unit change notification is the Edge/Level Triggered Event. | 1.3.6.1.4.1.26866.1.1.20 | current |