MIBs Depot

GEIST-V4-MIB

Registered at
1.3.6.1.4.1.21239.5.1
Last updated
2012-09-11 00:00
Organization
Geist
Revisions
2012-09-11 00:00
Namespace
geist
Source file
GEIST-V4-MIB
Digest
sha256:0876695e051eff5cfbdb82b854a3934aefe3baaa0fef55f549c34093a5bbeacb

Description

The MIB for Geist Products

Contact

support@geistglobal.com

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

GEIST-V4-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
blackbird
OBJECT-IDENTITY
1.3.6.1.4.1.21239.5
watchdog100
OBJECT-IDENTITY
1.3.6.1.4.1.21239.5.1
deviceInfo
OBJECT-IDENTITY
1.3.6.1.4.1.21239.5.1.1
productTitle
OBJECT-TYPE
Product name
1.3.6.1.4.1.21239.5.1.1.1DisplayStringread-onlycurrent
productVersion
OBJECT-TYPE
Product version
1.3.6.1.4.1.21239.5.1.1.2DisplayStringread-onlycurrent
productFriendlyName
OBJECT-TYPE
User-assigned name
1.3.6.1.4.1.21239.5.1.1.3DisplayStringread-onlycurrent
productMacAddress
OBJECT-TYPE
Product's unique MAC address
1.3.6.1.4.1.21239.5.1.1.4OCTET STRINGread-onlycurrent
productUrl
OBJECT-TYPE
Product's main URL access point
1.3.6.1.4.1.21239.5.1.1.5IpAddressread-onlycurrent
deviceCount
OBJECT-TYPE
Total number of devices on unit
1.3.6.1.4.1.21239.5.1.1.6Integer32 (0..100)read-onlycurrent
temperatureUnits
OBJECT-TYPE
Current units for temperature values. 0 = Degrees Fahrenheit, 1 = Degrees Celsius
1.3.6.1.4.1.21239.5.1.1.7Integer32 (0..1)read-writecurrent
internalTable
OBJECT-TYPE
Internal sensors for units
1.3.6.1.4.1.21239.5.1.2not-accessiblecurrent
internalEntry
OBJECT-TYPE
Entry in the internalTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.2.1not-accessiblecurrent
internalIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.2.1.1Integer32 (1..100)read-onlycurrent
internalSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.2.1.2DisplayStringread-onlycurrent
internalName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.2.1.3DisplayStringread-onlycurrent
internalAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.2.1.4Gauge32read-onlycurrent
internalTemp
OBJECT-TYPE
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.2.1.5Integer32 (-40..200)read-onlycurrent
internalHumidity
OBJECT-TYPE
Humidity reading
1.3.6.1.4.1.21239.5.1.2.1.6Integer32 (0..100)read-onlycurrent
internalDewPoint
OBJECT-TYPE
Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.2.1.7Integer32 (-40..200)read-onlycurrent
tempSensorTable
OBJECT-TYPE
Remote Temperature Sensor
1.3.6.1.4.1.21239.5.1.4not-accessiblecurrent
tempSensorEntry
OBJECT-TYPE
Entry in the tempSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.4.1not-accessiblecurrent
tempSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.4.1.1Integer32 (1..100)read-onlycurrent
tempSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.4.1.2DisplayStringread-onlycurrent
tempSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.4.1.3DisplayStringread-onlycurrent
tempSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.4.1.4Gauge32read-onlycurrent
tempSensorTemp
OBJECT-TYPE
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.4.1.5Integer32 (-40..200)read-onlycurrent
airFlowSensorTable
OBJECT-TYPE
Remote Airflow, Humidity, Temperature and Dewpoint Sensor
1.3.6.1.4.1.21239.5.1.5not-accessiblecurrent
airFlowSensorEntry
OBJECT-TYPE
Entry in the airFlowSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.5.1not-accessiblecurrent
airFlowSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.5.1.1Integer32 (1..100)read-onlycurrent
airFlowSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.5.1.2DisplayStringread-onlycurrent
airFlowSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.5.1.3DisplayStringread-onlycurrent
airFlowSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.5.1.4Gauge32read-onlycurrent
airFlowSensorTemp
OBJECT-TYPE
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.5.1.5Integer32 (-40..200)read-onlycurrent
airFlowSensorFlow
OBJECT-TYPE
AFHT3 Airflow reading
1.3.6.1.4.1.21239.5.1.5.1.6Integer32 (0..100)read-onlycurrent
airFlowSensorHumidity
OBJECT-TYPE
AFHT3 Humidity reading
1.3.6.1.4.1.21239.5.1.5.1.7Integer32 (0..100)read-onlycurrent
airFlowSensorDewPoint
OBJECT-TYPE
Current reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.5.1.8Integer32 (-40..200)read-onlycurrent
dewPointSensorTable
OBJECT-TYPE
Remote Dew Point sensor
1.3.6.1.4.1.21239.5.1.6not-accessiblecurrent
dewPointSensorEntry
OBJECT-TYPE
Entry in the dewPointSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.6.1not-accessiblecurrent
dewPointSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.6.1.1Integer32 (1..100)read-onlycurrent
dewPointSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.6.1.2DisplayStringread-onlycurrent
dewPointSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.6.1.3DisplayStringread-onlycurrent
dewPointSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.6.1.4Gauge32read-onlycurrent
dewPointSensorTemp
OBJECT-TYPE
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.6.1.5Integer32 (-40..200)read-onlycurrent
dewPointSensorHumidity
OBJECT-TYPE
Humidity reading
1.3.6.1.4.1.21239.5.1.6.1.6Integer32 (0..100)read-onlycurrent
dewPointSensorDewPoint
OBJECT-TYPE
Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.6.1.7Integer32 (-40..200)read-onlycurrent
ccatSensorTable
OBJECT-TYPE
Remote CCAT sensor
1.3.6.1.4.1.21239.5.1.7not-accessiblecurrent
ccatSensorEntry
OBJECT-TYPE
Entry in the ccatSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.7.1not-accessiblecurrent
ccatSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.7.1.1Integer32 (1..100)read-onlycurrent
ccatSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.7.1.2DisplayStringread-onlycurrent
ccatSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.7.1.3DisplayStringread-onlycurrent
ccatSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.7.1.4Gauge32read-onlycurrent
ccatSensorValue
OBJECT-TYPE
CCAT sensor reading
1.3.6.1.4.1.21239.5.1.7.1.5Integer32 (-100..5000)read-onlycurrent
ccatSensorType
OBJECT-TYPE
CCAT sensor type
1.3.6.1.4.1.21239.5.1.7.1.6DisplayStringread-onlycurrent
ccatSensorDescription
OBJECT-TYPE
CCAT sensor value description
1.3.6.1.4.1.21239.5.1.7.1.7DisplayStringread-onlycurrent
t3hdSensorTable
OBJECT-TYPE
Remote Temperature x 3, Humidity and Dewpoint Sensor
1.3.6.1.4.1.21239.5.1.8not-accessiblecurrent
t3hdSensorEntry
OBJECT-TYPE
Entry in the t3hdSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.8.1not-accessiblecurrent
t3hdSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.8.1.1Integer32 (1..100)read-onlycurrent
t3hdSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.8.1.2DisplayStringread-onlycurrent
t3hdSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.8.1.3DisplayStringread-onlycurrent
t3hdSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.8.1.4Gauge32read-onlycurrent
t3hdSensorIntName
OBJECT-TYPE
T3HD Sensor Internal Friendly Name
1.3.6.1.4.1.21239.5.1.8.1.5DisplayStringread-onlycurrent
t3hdSensorIntTemp
OBJECT-TYPE
Current reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.8.1.6Integer32 (-40..200)read-onlycurrent
t3hdSensorIntHumidity
OBJECT-TYPE
T3HD Sensor Internal Humidity
1.3.6.1.4.1.21239.5.1.8.1.7Integer32 (0..100)read-onlycurrent
t3hdSensorIntDewPoint
OBJECT-TYPE
Current reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.8.1.8Integer32 (-40..200)read-onlycurrent
t3hdSensorExtAAvail
OBJECT-TYPE
T3HD External A status: 0 = Unavailable, 1 = Available
1.3.6.1.4.1.21239.5.1.8.1.9Gauge32read-onlycurrent
t3hdSensorExtAName
OBJECT-TYPE
T3HD External A Friendly Name
1.3.6.1.4.1.21239.5.1.8.1.10DisplayStringread-onlycurrent
t3hdSensorExtATemp
OBJECT-TYPE
Current reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.8.1.11Integer32 (-40..200)read-onlycurrent
t3hdSensorExtBAvail
OBJECT-TYPE
T3HD External B status: 0 = Unavailable, 1 = Available
1.3.6.1.4.1.21239.5.1.8.1.12Gauge32read-onlycurrent
t3hdSensorExtBName
OBJECT-TYPE
T3HD External B Friendly Name
1.3.6.1.4.1.21239.5.1.8.1.13DisplayStringread-onlycurrent
t3hdSensorExtBTemp
OBJECT-TYPE
Current reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.8.1.14Integer32 (-40..200)read-onlycurrent
thdSensorTable
OBJECT-TYPE
Remote Temperature, Humidity and Dewpoint Sensor
1.3.6.1.4.1.21239.5.1.9not-accessiblecurrent
thdSensorEntry
OBJECT-TYPE
Entry in the thdSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.9.1not-accessiblecurrent
thdSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.9.1.1Integer32 (1..100)read-onlycurrent
thdSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.9.1.2DisplayStringread-onlycurrent
thdSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.9.1.3DisplayStringread-onlycurrent
thdSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.9.1.4Gauge32read-onlycurrent
thdSensorTemp
OBJECT-TYPE
Current reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.9.1.5Integer32 (-40..200)read-onlycurrent
thdSensorHumidity
OBJECT-TYPE
THD Sensor Humidity
1.3.6.1.4.1.21239.5.1.9.1.6Integer32 (0..100)read-onlycurrent
thdSensorDewPoint
OBJECT-TYPE
Current reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
1.3.6.1.4.1.21239.5.1.9.1.7Integer32 (-40..200)read-onlycurrent
rpmSensorTable
OBJECT-TYPE
Remote Power Manager Sensor
1.3.6.1.4.1.21239.5.1.10not-accessiblecurrent
rpmSensorEntry
OBJECT-TYPE
Entry in the rpmSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.10.1not-accessiblecurrent
rpmSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.10.1.1Integer32 (1..100)read-onlycurrent
rpmSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.10.1.2DisplayStringread-onlycurrent
rpmSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.10.1.3DisplayStringread-onlycurrent
rpmSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.10.1.4Gauge32read-onlycurrent
rpmSensorEnergy
OBJECT-TYPE
RPM Sensor Accumulated Energy
1.3.6.1.4.1.21239.5.1.10.1.5Gauge32read-onlycurrent
rpmSensorVoltage
OBJECT-TYPE
RPM Sensor Voltage
1.3.6.1.4.1.21239.5.1.10.1.6Gauge32read-onlycurrent
rpmSensorVoltageMax
OBJECT-TYPE
RPM Sensor Voltage (Max)
1.3.6.1.4.1.21239.5.1.10.1.7Gauge32read-onlycurrent
rpmSensorVoltageMin
OBJECT-TYPE
RPM Sensor Voltage (Min)
1.3.6.1.4.1.21239.5.1.10.1.8Gauge32read-onlycurrent
rpmSensorVoltagePeak
OBJECT-TYPE
RPM Sensor Voltage (Peak)
1.3.6.1.4.1.21239.5.1.10.1.9Gauge32read-onlycurrent
rpmSensorCurrent
OBJECT-TYPE
RPM Sensor Current reading in deciAmps
1.3.6.1.4.1.21239.5.1.10.1.10Gauge32read-onlycurrent
rpmSensorRealPower
OBJECT-TYPE
RPM Sensor Real Power
1.3.6.1.4.1.21239.5.1.10.1.11Gauge32read-onlycurrent
rpmSensorApparentPower
OBJECT-TYPE
RPM Sensor Apparent Power
1.3.6.1.4.1.21239.5.1.10.1.12Gauge32read-onlycurrent
rpmSensorPowerFactor
OBJECT-TYPE
RPM Sensor Power Factor
1.3.6.1.4.1.21239.5.1.10.1.13Gauge32read-onlycurrent
rpmSensorOutlet1
OBJECT-TYPE
RPM Sensor Outlet 1 State: 0 = off, 1 = on
1.3.6.1.4.1.21239.5.1.10.1.14Gauge32read-onlycurrent
rpmSensorOutlet2
OBJECT-TYPE
RPM Sensor Outlet 2 State: 0 = off, 1 = on
1.3.6.1.4.1.21239.5.1.10.1.15Gauge32read-onlycurrent
a2dSensorTable
OBJECT-TYPE
Analog Measurement Sensor (Voltage, Current, or Dry Contact)
1.3.6.1.4.1.21239.5.1.11not-accessiblecurrent
a2DSensorEntry
OBJECT-TYPE
Entry in the a2dSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.1.11.1not-accessiblecurrent
a2dSensorIndex
OBJECT-TYPE
Table entry index value
1.3.6.1.4.1.21239.5.1.11.1.1Integer32 (1..100)read-onlycurrent
a2dSensorSerial
OBJECT-TYPE
Serial Number
1.3.6.1.4.1.21239.5.1.11.1.2DisplayStringread-onlycurrent
a2dSensorName
OBJECT-TYPE
Friendly Name
1.3.6.1.4.1.21239.5.1.11.1.3DisplayStringread-onlycurrent
a2dSensorAvail
OBJECT-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.1.11.1.4Gauge32read-onlycurrent
a2dSensorValue
OBJECT-TYPE
Current analog measurement reading within either a user defined or preset range depending on device mode.
1.3.6.1.4.1.21239.5.1.11.1.5Integer32 (-1000000..1000000)read-onlycurrent
trap
OBJECT-IDENTITY
1.3.6.1.4.1.21239.5.1.32767
trapPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.21239.5.1.32767.0

Notifications

NameOIDStatus
internalTestNOTIFY
NOTIFICATION-TYPE
Test SNMP Trap
1.3.6.1.4.1.21239.5.1.32767.0.10101current
internalAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10204current
internalTempNOTIFY
NOTIFICATION-TYPE
Internal Temperature Sensor Trap
1.3.6.1.4.1.21239.5.1.32767.0.10205current
internalHumidityNOTIFY
NOTIFICATION-TYPE
Humidity reading Trap
1.3.6.1.4.1.21239.5.1.32767.0.10206current
internalDewPointNOTIFY
NOTIFICATION-TYPE
Internal Dew Point Sensor Trap
1.3.6.1.4.1.21239.5.1.32767.0.10207current
tempSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10404current
tempSensorTempNOTIFY
NOTIFICATION-TYPE
Remote Temperature Sensor Trap
1.3.6.1.4.1.21239.5.1.32767.0.10405current
airFlowSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10504current
airFlowSensorTempNOTIFY
NOTIFICATION-TYPE
AFHT3 Sensor Temperature Trap
1.3.6.1.4.1.21239.5.1.32767.0.10505current
airFlowSensorFlowNOTIFY
NOTIFICATION-TYPE
AFHT3 Airflow reading Trap
1.3.6.1.4.1.21239.5.1.32767.0.10506current
airFlowSensorHumidityNOTIFY
NOTIFICATION-TYPE
AFHT3 Humidity reading Trap
1.3.6.1.4.1.21239.5.1.32767.0.10507current
airFlowSensorDewPointNOTIFY
NOTIFICATION-TYPE
AFHT3 Sensor Dew Point Trap
1.3.6.1.4.1.21239.5.1.32767.0.10508current
dewPointSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10604current
dewPointSensorTempNOTIFY
NOTIFICATION-TYPE
Remote Dew Point Sensor Temperature Trap
1.3.6.1.4.1.21239.5.1.32767.0.10605current
dewPointSensorHumidityNOTIFY
NOTIFICATION-TYPE
Humidity reading Trap
1.3.6.1.4.1.21239.5.1.32767.0.10606current
dewPointSensorDewPointNOTIFY
NOTIFICATION-TYPE
Remote Dew Point Sensor Dew Point Trap
1.3.6.1.4.1.21239.5.1.32767.0.10607current
ccatSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10704current
ccatSensorValueNOTIFY
NOTIFICATION-TYPE
CCAT sensor reading Trap
1.3.6.1.4.1.21239.5.1.32767.0.10705current
t3hdSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10804current
t3hdSensorIntTempNOTIFY
NOTIFICATION-TYPE
T3HD Sensor Temperature Trap
1.3.6.1.4.1.21239.5.1.32767.0.10806current
t3hdSensorIntHumidityNOTIFY
NOTIFICATION-TYPE
T3HD Sensor Internal Humidity Trap
1.3.6.1.4.1.21239.5.1.32767.0.10807current
t3hdSensorIntDewPointNOTIFY
NOTIFICATION-TYPE
T3HD Sensor Dew Point Trap
1.3.6.1.4.1.21239.5.1.32767.0.10808current
t3hdSensorExtATempNOTIFY
NOTIFICATION-TYPE
T3HD Sensor External A Temperature Trap
1.3.6.1.4.1.21239.5.1.32767.0.10811current
t3hdSensorExtBTempNOTIFY
NOTIFICATION-TYPE
T3HD Sensor External B Temperature Trap
1.3.6.1.4.1.21239.5.1.32767.0.10814current
thdSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.10904current
thdSensorTempNOTIFY
NOTIFICATION-TYPE
THD Sensor Temperature Trap
1.3.6.1.4.1.21239.5.1.32767.0.10905current
thdSensorHumidityNOTIFY
NOTIFICATION-TYPE
THD Sensor Humidity Trap
1.3.6.1.4.1.21239.5.1.32767.0.10906current
thdSensorDewPointNOTIFY
NOTIFICATION-TYPE
THD Sensor Dew Point Trap
1.3.6.1.4.1.21239.5.1.32767.0.10907current
rpmSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.11004current
rpmSensorEnergyNOTIFY
NOTIFICATION-TYPE
RPM Sensor Accumulated Energy Trap
1.3.6.1.4.1.21239.5.1.32767.0.11005current
rpmSensorVoltageNOTIFY
NOTIFICATION-TYPE
RPM Sensor Voltage Trap
1.3.6.1.4.1.21239.5.1.32767.0.11006current
rpmSensorVoltageMaxNOTIFY
NOTIFICATION-TYPE
RPM Sensor Voltage (Max) Trap
1.3.6.1.4.1.21239.5.1.32767.0.11007current
rpmSensorVoltageMinNOTIFY
NOTIFICATION-TYPE
RPM Sensor Voltage (Min) Trap
1.3.6.1.4.1.21239.5.1.32767.0.11008current
rpmSensorVoltagePeakNOTIFY
NOTIFICATION-TYPE
RPM Sensor Voltage (Peak) Trap
1.3.6.1.4.1.21239.5.1.32767.0.11009current
rpmSensorCurrentNOTIFY
NOTIFICATION-TYPE
RPM Sensor Current Trap
1.3.6.1.4.1.21239.5.1.32767.0.11010current
rpmSensorRealPowerNOTIFY
NOTIFICATION-TYPE
RPM Sensor Real Power Trap
1.3.6.1.4.1.21239.5.1.32767.0.11011current
rpmSensorApparentPowerNOTIFY
NOTIFICATION-TYPE
RPM Sensor Apparent Power Trap
1.3.6.1.4.1.21239.5.1.32767.0.11012current
rpmSensorPowerFactorNOTIFY
NOTIFICATION-TYPE
RPM Sensor Power Factor Trap
1.3.6.1.4.1.21239.5.1.32767.0.11013current
a2dSensorAvailNOTIFY
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
1.3.6.1.4.1.21239.5.1.32767.0.11104current
a2dSensorValueNOTIFY
NOTIFICATION-TYPE
A2D Analog Sensor Measurement Trap
1.3.6.1.4.1.21239.5.1.32767.0.11105current
internalAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20204current
internalTempCLEAR
NOTIFICATION-TYPE
Internal Temperature Sensor Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20205current
internalHumidityCLEAR
NOTIFICATION-TYPE
Humidity reading Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20206current
internalDewPointCLEAR
NOTIFICATION-TYPE
Internal Dew Point Sensor Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20207current
tempSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20404current
tempSensorTempCLEAR
NOTIFICATION-TYPE
Remote Temperature Sensor Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20405current
airFlowSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20504current
airFlowSensorTempCLEAR
NOTIFICATION-TYPE
AFHT3 Sensor Temperature Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20505current
airFlowSensorFlowCLEAR
NOTIFICATION-TYPE
AFHT3 Airflow reading Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20506current
airFlowSensorHumidityCLEAR
NOTIFICATION-TYPE
AFHT3 Humidity reading Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20507current
airFlowSensorDewPointCLEAR
NOTIFICATION-TYPE
AFHT3 Sensor Dew Point Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20508current
dewPointSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20604current
dewPointSensorTempCLEAR
NOTIFICATION-TYPE
Remote Dew Point Sensor Temperature Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20605current
dewPointSensorHumidityCLEAR
NOTIFICATION-TYPE
Humidity reading Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20606current
dewPointSensorDewPointCLEAR
NOTIFICATION-TYPE
Remote Dew Point Sensor Dew Point Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20607current
ccatSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20704current
ccatSensorValueCLEAR
NOTIFICATION-TYPE
CCAT sensor reading Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20705current
t3hdSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20804current
t3hdSensorIntTempCLEAR
NOTIFICATION-TYPE
T3HD Sensor Temperature Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20806current
t3hdSensorIntHumidityCLEAR
NOTIFICATION-TYPE
T3HD Sensor Internal Humidity Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20807current
t3hdSensorIntDewPointCLEAR
NOTIFICATION-TYPE
T3HD Sensor Dew Point Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20808current
t3hdSensorExtATempCLEAR
NOTIFICATION-TYPE
T3HD Sensor External A Temperature Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20811current
t3hdSensorExtBTempCLEAR
NOTIFICATION-TYPE
T3HD Sensor External B Temperature Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20814current
thdSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20904current
thdSensorTempCLEAR
NOTIFICATION-TYPE
THD Sensor Temperature Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20905current
thdSensorHumidityCLEAR
NOTIFICATION-TYPE
THD Sensor Humidity Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20906current
thdSensorDewPointCLEAR
NOTIFICATION-TYPE
THD Sensor Dew Point Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.20907current
rpmSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21004current
rpmSensorEnergyCLEAR
NOTIFICATION-TYPE
RPM Sensor Accumulated Energy Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21005current
rpmSensorVoltageCLEAR
NOTIFICATION-TYPE
RPM Sensor Voltage Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21006current
rpmSensorVoltageMaxCLEAR
NOTIFICATION-TYPE
RPM Sensor Voltage (Max) Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21007current
rpmSensorVoltageMinCLEAR
NOTIFICATION-TYPE
RPM Sensor Voltage (Min) Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21008current
rpmSensorVoltagePeakCLEAR
NOTIFICATION-TYPE
RPM Sensor Voltage (Peak) Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21009current
rpmSensorCurrentCLEAR
NOTIFICATION-TYPE
RPM Sensor Current Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21010current
rpmSensorRealPowerCLEAR
NOTIFICATION-TYPE
RPM Sensor Real Power Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21011current
rpmSensorApparentPowerCLEAR
NOTIFICATION-TYPE
RPM Sensor Apparent Power Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21012current
rpmSensorPowerFactorCLEAR
NOTIFICATION-TYPE
RPM Sensor Power Factor Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21013current
a2dSensorAvailCLEAR
NOTIFICATION-TYPE
Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21104current
a2dSensorValueCLEAR
NOTIFICATION-TYPE
A2D Analog Sensor Measurement Clear Trap
1.3.6.1.4.1.21239.5.1.32767.0.21105current