MIBs Depot

G6-SYSTEM-MIB

Registered at
1.3.6.1.4.1.3181.10.6.1.30
Last updated
2015-05-22 10:59
Organization
MICROSENS GmbH & Co. KG
Revisions
2015-05-22 10:59
Namespace
microsens
Source file
G6-SYSTEM-MIB
Digest
sha256:5ca879b2fc6a6ef48f58fb8d5b866f50449090b43bebfbb65a020ae7c219ce10

Description

Microsens private MIB for Generation 6 Ethernet Switches

Contact

Kueferstrasse 16 D-59067 Hamm Germany support@microsens.de http://www.microsens.de

Imports

FromSymbols
MICROSENS-G6-MIBg6
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, MacAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

G6-SYSTEM-MIB
MICROSENS-G6-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
system
OBJECT-IDENTITY
1.3.6.1.4.1.3181.10.6.1.30
systemShowTimeDate
OBJECT-TYPE
Show system time and date.
1.3.6.1.4.1.3181.10.6.1.30.1DisplayStringread-writecurrent
systemSetTime
OBJECT-TYPE
Sets the system clock (time only). Syntax: 12:30:00
1.3.6.1.4.1.3181.10.6.1.30.2DisplayStringread-writecurrent
systemSetDate
OBJECT-TYPE
Sets the system clock (date only). Syntax: 2012-12-24
1.3.6.1.4.1.3181.10.6.1.30.3DisplayStringread-writecurrent
systemShowUtilization
OBJECT-TYPE
Show CPU status information
1.3.6.1.4.1.3181.10.6.1.30.4DisplayStringread-writecurrent
systemRebootDevice
OBJECT-TYPE
This command will restart the device. All communication will be disrupted! Syntax: reboot_device = CONFIRM.
1.3.6.1.4.1.3181.10.6.1.30.5DisplayStringread-writecurrent
systemCreateSnapshot
OBJECT-TYPE
Creates a snapshot of all relevant configuration and status information packaged as a single tar archieve. This file can be found in service/snapshot.
1.3.6.1.4.1.3181.10.6.1.30.6DisplayStringread-writecurrent
systemSendWakeOnLanPacket
OBJECT-TYPE
This command will send a magic packet to wake up a selected sleeping device. The device is identified by its MAC address. Syntax: send_wake_on_lan_packet = 00:11:22:44:55:66.
1.3.6.1.4.1.3181.10.6.1.30.7DisplayStringread-writecurrent
systemAlternativeMacAddress
OBJECT-TYPE
This field is usually empty. This field may be used to override the MAC address fixed in the factory setting. NOTE: This value is read only after a reset!
1.3.6.1.4.1.3181.10.6.1.30.8MacAddressread-writecurrent
systemBootPreference
OBJECT-TYPE
This feature only applies to devices that feature internal memory plus plugged-in SD cards. It defines which software is used after reboot.
1.3.6.1.4.1.3181.10.6.1.30.9INTEGER {sdCardFirst(0), internalFirst(1), sdCardOnly(2), internalOnly(3)}read-writecurrent
systemInventory
OBJECT-TYPE
Inventory string free for customer use. Up to 512 character are accepted. Note this config is linked to the SD card and may change when config or SD card is exchanged. For an inventory that is fixed to the hardware use device.system.set_factory_inventory command.
1.3.6.1.4.1.3181.10.6.1.30.10DisplayStringread-writecurrent
systemAutorunCliScript
OBJECT-TYPE
Optional cli scripts executed after power sequence is completed. Several scripts may be assigned, with comma or blank separation.
1.3.6.1.4.1.3181.10.6.1.30.11DisplayStringread-writecurrent
systemLocalConsole
OBJECT-TYPE
When set to disabled the local serial console port is disabled. Local access via serial cable is blocked. While this enhances local protection it also closes the emergency access should the device become inaccessible over the network due to misconfiguration. The port is also set to disabled, when serial port extension hardware is installed.
1.3.6.1.4.1.3181.10.6.1.30.12INTEGER {disabled(0), enabled(1)}read-writecurrent
systemPermitDebugAccess
OBJECT-TYPE
When enabled it is possible to log into the system for debug purposes. This includes telnet/ssh, as well as web and file transfer protocols. To protect the system from unauthorized access it is strongly advised to disable this feature unless instructed by authorized service personnel. NOTE: To ensure that any possibly pending debug access is terminated reboot the device after setting this parameter to disabled.
1.3.6.1.4.1.3181.10.6.1.30.13INTEGER {disabled(0), enabled(1)}read-writecurrent
systemPermitIncomingAlerts
OBJECT-TYPE
When enabled it is possible receive alerts via from external devices via SNMP or HTTP(S). This feature may be used in combination with custom scripting to react to external events. To protect the system from unauthorized spam it is advised to disable this feature unless there is an application for it.
1.3.6.1.4.1.3181.10.6.1.30.14INTEGER {disabled(0), enabled(1)}read-writecurrent
scriptScheduleTable
OBJECT-TYPE
This dynamic table permits the setup of automated script execution based on precise time scheduling definition. Any number of scripts may be executed at any desired interval or at selected dates. Please ensure the time and date are properly set (via NTP) when using this feature.
1.3.6.1.4.1.3181.10.6.1.30.15not-accessiblecurrent
scriptScheduleEntry
OBJECT-TYPE
1.3.6.1.4.1.3181.10.6.1.30.15.1not-accessiblecurrent
scriptScheduleIndex
OBJECT-TYPE
Automatically generated
1.3.6.1.4.1.3181.10.6.1.30.15.1.1INTEGER (0..31)not-accessiblecurrent
scriptScheduleName
OBJECT-TYPE
Unique name to reference this entry and to remember whose MAC address is entered.
1.3.6.1.4.1.3181.10.6.1.30.15.1.2DisplayStringread-writecurrent
scriptScheduleMode
OBJECT-TYPE
When set to disabled this entry is ignored. It is recommended to first set the mode to disabled before the associated time values are modified. When all values are properly set re-enable the entry.
1.3.6.1.4.1.3181.10.6.1.30.15.1.3INTEGER {disabled(0), enabled(1)}read-writecurrent
scriptScheduleCliScript
OBJECT-TYPE
Enter the name of the cli script that should be executed when the defined time occurs. Ensure that the script name selects a valid file. Several scripts may be assigned, with comma or blank separation.
1.3.6.1.4.1.3181.10.6.1.30.15.1.4DisplayStringread-writecurrent
scriptScheduleMinutes
OBJECT-TYPE
Format: 3,14 select exact minutes hour:03 and hour:14. * is every minute. */5 defines every five minutes.
1.3.6.1.4.1.3181.10.6.1.30.15.1.5DisplayStringread-writecurrent
scriptScheduleHours
OBJECT-TYPE
Format: 0-23. Range and comma separation is permitted. * is every hour.
1.3.6.1.4.1.3181.10.6.1.30.15.1.6DisplayStringread-writecurrent
scriptScheduleDays
OBJECT-TYPE
Format: 1-31. Range and comma separation is permitted. * is every day.
1.3.6.1.4.1.3181.10.6.1.30.15.1.7DisplayStringread-writecurrent
scriptScheduleMonths
OBJECT-TYPE
Format: 1-12 or Jan-Dec. Range and comma separation is permitted. * is every month.
1.3.6.1.4.1.3181.10.6.1.30.15.1.8DisplayStringread-writecurrent
scriptScheduleWeekdays
OBJECT-TYPE
Format: 0-6 or Sun-Sat. Range and comma separation is permitted. * is every day.
1.3.6.1.4.1.3181.10.6.1.30.15.1.9DisplayStringread-writecurrent
systemLastBootTime
OBJECT-TYPE
The time and date when this device has booted.
1.3.6.1.4.1.3181.10.6.1.30.100DisplayStringread-onlycurrent
systemUptime
OBJECT-TYPE
Uptime since last reboot in seconds.
1.3.6.1.4.1.3181.10.6.1.30.101Counter32read-onlycurrent
systemUsedMacAddress
OBJECT-TYPE
Contains the mac address used by this unit. Usually follows to MAC defined in the factory setting, but may be overwritten by the alternative_mac_address.
1.3.6.1.4.1.3181.10.6.1.30.102MacAddressread-onlycurrent
systemUsedBootMedia
OBJECT-TYPE
1.3.6.1.4.1.3181.10.6.1.30.103INTEGER {sdCard(0), internalMemory(1), nfs(2)}read-onlycurrent
systemTemperature
OBJECT-TYPE
Temperature value in centigrade.
1.3.6.1.4.1.3181.10.6.1.30.104Integer32 (0..255)read-onlycurrent
systemClimateLevel
OBJECT-TYPE
Annotated temperature level.
1.3.6.1.4.1.3181.10.6.1.30.105INTEGER {unknown(0), criticalLow(1), low(2), normal(3), increased(4), high(5), criticalHigh(6), shutdown(7)}read-onlycurrent
firmwareTable
OBJECT-TYPE
This section provides details about the running firmware.
1.3.6.1.4.1.3181.10.6.1.30.106not-accessiblecurrent
firmwareEntry
OBJECT-TYPE
1.3.6.1.4.1.3181.10.6.1.30.106.1not-accessiblecurrent
firmwareIndex
OBJECT-TYPE
Automatically generated
1.3.6.1.4.1.3181.10.6.1.30.106.1.1INTEGER (0)not-accessiblecurrent
firmwareRunningVersion
OBJECT-TYPE
Running firmware version.
1.3.6.1.4.1.3181.10.6.1.30.106.1.2DisplayStringread-onlycurrent
firmwareBuildDate
OBJECT-TYPE
Build date of the running firmware. Format: 2012-01-18 12:00:22.
1.3.6.1.4.1.3181.10.6.1.30.106.1.3DisplayStringread-onlycurrent
firmwareBuildNumber
OBJECT-TYPE
Build number of the running firmware retrieved from the repository.
1.3.6.1.4.1.3181.10.6.1.30.106.1.4Unsigned32read-onlycurrent
saveInfoTable
OBJECT-TYPE
This section provided status information about the internal parameter saving process.
1.3.6.1.4.1.3181.10.6.1.30.107not-accessiblecurrent
saveInfoEntry
OBJECT-TYPE
1.3.6.1.4.1.3181.10.6.1.30.107.1not-accessiblecurrent
saveInfoIndex
OBJECT-TYPE
Automatically generated
1.3.6.1.4.1.3181.10.6.1.30.107.1.1INTEGER (0)not-accessiblecurrent
saveInfoLastSavedParameter
OBJECT-TYPE
Records the last written parameter.
1.3.6.1.4.1.3181.10.6.1.30.107.1.2DisplayStringread-onlycurrent
saveInfoWriteStatus
OBJECT-TYPE
Indicates if writing was succcessful.
1.3.6.1.4.1.3181.10.6.1.30.107.1.3INTEGER {nothingToSave(0), processing(1), savedToRam(2), savedToSdcard(3)}read-onlycurrent
saveInfoTimeStamp
OBJECT-TYPE
Records the time the write status was last changed.
1.3.6.1.4.1.3181.10.6.1.30.107.1.4Counter32read-onlycurrent