FRSLD-MIB
- Registered at
- 1.3.6.1.2.1.95
- Last updated
- 2002-01-03 00:00
- Organization
- IETF Frame Relay Service MIB Working Group
- Revisions
- 2002-01-03 00:00
- Namespace
- standard
- Source file
FRSLD-MIB- Digest
sha256:8b6d96d84199f803bac59a4ca906af77ca80baef601b3420927add64d7a5f8b7
Description
The MIB module to describe generic objects for FRF.13 Frame Relay Service Level Definitions.
Contact
IETF Frame Relay Service MIB (frnetmib) Working Group WG Charter: http://www.ietf.org/html.charters/ frnetmib-charter.html WG-email: frnetmib@sunroof.eng.sun.com Subscribe: frnetmib-request@sunroof.eng.sun.com Email Archive: ftp://ftp.ietf.org/ietf-mail-archive/frnetmib Chair: Andy Malis Vivace Networks Email: Andy.Malis@vivacenetworks.com WG editor: Robert Steinberger Paradyne Networks and Fujitsu Network Communications Email: robert.steinberger@fnc.fujitsu.com Co-author: Orly Nicklass RAD Data Communications Ltd. EMail: Orly_n@rad.co.il
Imports
| From | Symbols |
|---|---|
| FRAME-RELAY-DTE-MIB | DLCI |
| HCNUM-TC | CounterBasedGauge64 |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Counter64, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso, mib-2 |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
FRAME-RELAY-DTE-MIB FRSLD-MIB HCNUM-TC IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| FrsldRxRP TEXTUAL-CONVENTION The reference point a PVC uses for calculation of receiver related statistics. The valid values for this object are as follows: - desLocalRP(1) for the local destination - ingRxLocalRP(2) for the local ingress queue input - tpRxLocalRP(3) for the local traffic policing - eqiRxLocalRP(4) for the local egress queue input - eqoRxLocalRP(5) for the local egress queue output - otherRxLocalRP(6) for any other local receive point - desRemoteRP(7) for the remote destination - ingRxRemoteRP(8) for the remote ingress input - tpRxRemoteRP(9) for the remote traffic policing - eqiRxRemoteRP(10) for the remote egress queue input - eqoRxRemoteRP(11) for the remote egress queue output - otherRxRemoteRP(12) for any other remote receive point | current | |||
| FrsldTxRP TEXTUAL-CONVENTION The reference point a PVC uses for calculation of transmitter related statistics. The valid values for this type of object are as follows: - srcLocalRP(1) for the local source - ingTxLocalRP(2) for the local ingress queue input - tpTxLocalRP(3) for the local traffic policing - eqiTxLocalRP(4) for the local egress queue input - eqoTxLocalRP(5) for the local egress queue output - otherTxLocalRP(6) for any other local transmit point - srcRemoteRP(7) for the remote source - ingTxLocalRP(8) for the remote ingress queue input - tpTxLocalRP(9) for the remote traffic policing - eqiTxRemoteRP(10) for the remote egress queue input - eqoTxRemoteRP(11) for the remote egress queue output - otherTxRemoteRP(12) for any other remote xmit point | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| frsldObjects OBJECT-IDENTITY | 1.3.6.1.2.1.95.1 | |||
| frsldPvcCtrlTable OBJECT-TYPE The Frame Relay Service Level Definitions PVC control table. | 1.3.6.1.2.1.95.1.1 | not-accessible | current | |
| frsldPvcCtrlEntry OBJECT-TYPE An entry in the Frame Relay Service Level Definitions PVC control table. | 1.3.6.1.2.1.95.1.1.1 | not-accessible | current | |
| frsldPvcCtrlDlci OBJECT-TYPE The value of this object is equal to the DLCI value for this PVC. | 1.3.6.1.2.1.95.1.1.1.1 | DLCI | not-accessible | current |
| frsldPvcCtrlTransmitRP OBJECT-TYPE The reference point this PVC uses for calculation of transmitter related statistics. This object together with frsldPvcCtrlReceiveRP define the measurement domain. | 1.3.6.1.2.1.95.1.1.1.2 | FrsldTxRP | not-accessible | current |
| frsldPvcCtrlReceiveRP OBJECT-TYPE The reference point this PVC uses for calculation of receiver related statistics. This object together with frsldPvcCtrlTransmitRP define the measurement domain. | 1.3.6.1.2.1.95.1.1.1.3 | FrsldRxRP | not-accessible | current |
| frsldPvcCtrlStatus OBJECT-TYPE The status of the current row. This object is used to add, delete, and disable rows in this table. When the status changes to active(1) for the first time, a row will also be added to the data table below. This row SHOULD not be removed until the status is changed to deleted. When this object is set to destroy(6), all associated sample and data table rows will also be deleted. When this object is changed from active(1) to any other valid value, the defined purge behavior will affect the data and sample tables. The rows added to this table MUST have a valid ifIndex and an ifType related to frame relay. Further, the reference points referred to by frsldPvcCtrlTransmitRP and frsldPvcCtrlReceiveRP MUST be supported (see the frsldRPCaps object). If at any point the row is not in the active(1) state and the DLCI no longer exists, the state SHOULD report notReady(3). The data in this table SHOULD persist through power cycles. The symantics of readiness for the rows still applies. This means that it is possible for a row to be reprovisioned as notReady(3) if the underlying DLCI does not persist. | 1.3.6.1.2.1.95.1.1.1.4 | RowStatus | read-create | current |
| frsldPvcCtrlPacketFreq OBJECT-TYPE The frequency in seconds between initiation of specialized packets used to collect delay and / or delivery information as supported by the device. A value of zero indicates that no packets will be sent. | 1.3.6.1.2.1.95.1.1.1.5 | Integer32 (0..3600) | read-create | current |
| frsldPvcCtrlDelayFrSize OBJECT-TYPE The size of the payload in the frame used for calculation of network delay. | 1.3.6.1.2.1.95.1.1.1.6 | Integer32 (1..8188) | read-create | current |
| frsldPvcCtrlDelayType OBJECT-TYPE The type of delay measurement performed. | 1.3.6.1.2.1.95.1.1.1.7 | INTEGER {oneWay(1), roundTrip(2)} | read-create | current |
| frsldPvcCtrlDelayTimeOut OBJECT-TYPE A delay frame will count as a missed poll if it is not updated in the time specified by frsldPvcCtrlDelayTimeOut. | 1.3.6.1.2.1.95.1.1.1.8 | Integer32 (1..3600) | read-create | current |
| frsldPvcCtrlPurge OBJECT-TYPE This object defines the amount of time the device will wait, after discovering that a DLCI does not exist, the DLCI was deleted or the value of frsldPvcCtrlStatus changes from active(1) to either notInService(2) or notReady(3), prior to automatically purging the history in the sample tables and resetting the data in the data tables to all zeroes. If frsldPvcCtrlStatus is manually set to destroy(6), this object does not apply. | 1.3.6.1.2.1.95.1.1.1.9 | Integer32 (0..172800) | read-create | current |
| frsldPvcCtrlDeleteOnPurge OBJECT-TYPE This object defines whether rows will automatically be deleted from the tables when the information is purged. - A value of none(1) indicates that no rows will deleted. The last known values will be preserved. - A value of sampleControls(2) indicates that all associated sample control rows will be deleted. - A value of all(3) indicates that all associated rows SHOULD be deleted. | 1.3.6.1.2.1.95.1.1.1.10 | INTEGER {none(1), sampleContols(2), all(3)} | read-create | current |
| frsldPvcCtrlLastPurgeTime OBJECT-TYPE This object returns the value of sysUpTime at the time the information was last purged. This value SHOULD be set to the sysUpTime upon setting frsldPvcCtrlStatus to active(1) for the first time. Each time a discontinuity in the counters occurs, this value MUST be set to the sysUpTime. If frsldPvcCtrlStatus has never been active(1), this object SHOULD return 0. This object SHOULD be used as the discontinuity timer for the counters in frsldPvcDataTable. | 1.3.6.1.2.1.95.1.1.1.11 | TimeStamp | read-only | current |
| frsldSmplCtrlTable OBJECT-TYPE The Frame Relay Service Level Definitions sampling control table. | 1.3.6.1.2.1.95.1.2 | not-accessible | current | |
| frsldSmplCtrlEntry OBJECT-TYPE An entry in the Frame Relay Service Level Definitions sample control table. | 1.3.6.1.2.1.95.1.2.1 | not-accessible | current | |
| frsldSmplCtrlIdx OBJECT-TYPE The unique index for this row in the sample control table. | 1.3.6.1.2.1.95.1.2.1.1 | Integer32 (1..256) | not-accessible | current |
| frsldSmplCtrlStatus OBJECT-TYPE The status of the current row. This object is used to add, delete, and disable rows in this table. This row SHOULD NOT be removed until the status is changed to destroy(6). When the status changes to active(1), the collection in the sample tables below will be activated. The rows added to this table MUST have a valid ifIndex, an ifType related to frame relay, frsldPvcCtrlDlci MUST exist for the specified ifIndex and frsldPvcCtrlStatus MUST have a value of active(1). The value of frsldPvcCtrlStatus MUST be active(1) to transition this object to active(1). If the value of frsldPvcCtrlStatus becomes anything other than active(1) when the state of this object is not active(1), this object SHOULD be set to notReady(3). The data in this table SHOULD persist through power cycles. The symantics of readiness for the rows still applies. This means that it is possible for a row to be reprovisioned as notReady(3) if the underlying DLCI does not persist. | 1.3.6.1.2.1.95.1.2.1.2 | RowStatus | read-create | current |
| frsldSmplCtrlColPeriod OBJECT-TYPE The amount of time in seconds that defines a period of collection for the statistics. At the end of each period, the statistics will be sampled and a row is added to the sample table. | 1.3.6.1.2.1.95.1.2.1.3 | Integer32 (1..2147483647) | read-create | current |
| frsldSmplCtrlBuckets OBJECT-TYPE The number of discrete buckets over which the data statistics are sampled. When this object is created or modified, the device SHOULD attempt to set the frsldSmplCtrlBuckets- Granted to a value as close as is possible depending upon the implementation and the available resources. | 1.3.6.1.2.1.95.1.2.1.4 | Integer32 (1..65535) | read-create | current |
| frsldSmplCtrlBucketsGranted OBJECT-TYPE The number of discrete buckets granted. This object will return 0 until frsldSmplCtrlStatus is set to active(1). At that time the buckets will be allocated depending upon implementation and available resources. | 1.3.6.1.2.1.95.1.2.1.5 | Integer32 (0..65535) | read-only | current |
| frsldPvcDataTable OBJECT-TYPE The Frame Relay Service Level Definitions data table. This table contains accumulated values of the collected data. It is the table that should be referenced by external polling mechanisms if time based polling be desired. | 1.3.6.1.2.1.95.1.3 | not-accessible | current | |
| frsldPvcDataEntry OBJECT-TYPE An entry in the Frame Relay Service Level Definitions data table. | 1.3.6.1.2.1.95.1.3.1 | not-accessible | current | |
| frsldPvcDataMissedPolls OBJECT-TYPE The total number of polls that have been determined to be missed. These polls are typically associated with the calculation of delay but may also be used for the calculation of other statistics. If an anticipated poll is not received in a reasonable amount of time, it should be counted as missed. The value used to determine the reasonable amount of time is contained in frsldPvcCtrlDelayTimeOut. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.1 | Counter32 | read-only | current |
| frsldPvcDataFrDeliveredC OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.2 | Counter32 | read-only | current |
| frsldPvcDataFrDeliveredE OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.3 | Counter32 | read-only | current |
| frsldPvcDataFrOfferedC OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP within CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.4 | Counter32 | read-only | current |
| frsldPvcDataFrOfferedE OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP in excess of the CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.5 | Counter32 | read-only | current |
| frsldPvcDataDataDeliveredC OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.6 | Counter32 | read-only | current |
| frsldPvcDataDataDeliveredE OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.7 | Counter32 | read-only | current |
| frsldPvcDataDataOfferedC OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP within CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.8 | Counter32 | read-only | current |
| frsldPvcDataDataOfferedE OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP in excess of the CIR. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.9 | Counter32 | read-only | current |
| frsldPvcDataHCFrDeliveredC OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR. This object is a 64-bit version of frsldPvcDataFrDeliveredC. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.10 | Counter64 | read-only | current |
| frsldPvcDataHCFrDeliveredE OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR. This object is a 64-bit version of frsldPvcDataFrDeliveredE. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.11 | Counter64 | read-only | current |
| frsldPvcDataHCFrOfferedC OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP within CIR. This object is a 64-bit version of frsldPvcDataFrOfferedC. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.12 | Counter64 | read-only | current |
| frsldPvcDataHCFrOfferedE OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP in excess of the CIR. This object is a 64-bit version of frsldPvcDataFrOfferedE. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.13 | Counter64 | read-only | current |
| frsldPvcDataHCDataDeliveredC OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR. This object is a 64-bit version of frsldPvcDataDataDeliveredC. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.14 | Counter64 | read-only | current |
| frsldPvcDataHCDataDeliveredE OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR. This object is a 64-bit version of frsldPvcDataDataDeliveredE. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.15 | Counter64 | read-only | current |
| frsldPvcDataHCDataOfferedC OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP within CIR. This object is a 64-bit version of frsldPvcDataDataOfferedC. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.16 | Counter64 | read-only | current |
| frsldPvcDataHCDataOfferedE OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP in excess of the CIR. This object is a 64-bit version of frsldPvcDataDataOfferedE. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.17 | Counter64 | read-only | current |
| frsldPvcDataUnavailableTime OBJECT-TYPE The amount of time this PVC was declared unavailable for any reason since this row was created. | 1.3.6.1.2.1.95.1.3.1.18 | TimeTicks | read-only | current |
| frsldPvcDataUnavailables OBJECT-TYPE The number of times this PVC was declared unavailable for any reason since this row was created. Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by frsldPvcCtrlLastPurgeTime. | 1.3.6.1.2.1.95.1.3.1.19 | Counter32 | read-only | current |
| frsldPvcSampleTable OBJECT-TYPE The Frame Relay Service Level Definitions sample table. | 1.3.6.1.2.1.95.1.4 | not-accessible | current | |
| frsldPvcSampleEntry OBJECT-TYPE An entry in the Frame Relay Service Level Definitions data sample table. | 1.3.6.1.2.1.95.1.4.1 | not-accessible | current | |
| frsldPvcSmplIdx OBJECT-TYPE The bucket index of the current sample. This increments once for each new bucket in the table. | 1.3.6.1.2.1.95.1.4.1.1 | Integer32 (1..2147483647) | not-accessible | current |
| frsldPvcSmplDelayMin OBJECT-TYPE The minimum delay reported in microseconds measured for any information packet that arrived during this interval. A value of zero means that no data is available. | 1.3.6.1.2.1.95.1.4.1.2 | Gauge32 | read-only | current |
| frsldPvcSmplDelayMax OBJECT-TYPE The largest delay reported in microseconds measured for any information packet that arrived during this interval. A value of zero means that no data is available. | 1.3.6.1.2.1.95.1.4.1.3 | Gauge32 | read-only | current |
| frsldPvcSmplDelayAvg OBJECT-TYPE The average delay reported in microseconds measured for all delay packets that arrived during this interval. A value of zero means that no data is available. | 1.3.6.1.2.1.95.1.4.1.4 | Gauge32 | read-only | current |
| frsldPvcSmplMissedPolls OBJECT-TYPE The total number of polls that were missed during this interval. | 1.3.6.1.2.1.95.1.4.1.5 | Gauge32 | read-only | current |
| frsldPvcSmplFrDeliveredC OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCFrDeliveredC. | 1.3.6.1.2.1.95.1.4.1.6 | Gauge32 | read-only | current |
| frsldPvcSmplFrDeliveredE OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCFrDeliveredE. | 1.3.6.1.2.1.95.1.4.1.7 | Gauge32 | read-only | current |
| frsldPvcSmplFrOfferedC OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCFrOfferedC. | 1.3.6.1.2.1.95.1.4.1.8 | Gauge32 | read-only | current |
| frsldPvcSmplFrOfferedE OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCFrOfferedE. | 1.3.6.1.2.1.95.1.4.1.9 | Gauge32 | read-only | current |
| frsldPvcSmplDataDeliveredC OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataDeliveredC. | 1.3.6.1.2.1.95.1.4.1.10 | Gauge32 | read-only | current |
| frsldPvcSmplDataDeliveredE OBJECT-TYPE The number of octets that were received at frsldPvcCtrlDeliveredRP and determined to have been sent in excess of the CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataDeliveredE. | 1.3.6.1.2.1.95.1.4.1.11 | Gauge32 | read-only | current |
| frsldPvcSmplDataOfferedC OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataOfferredC. | 1.3.6.1.2.1.95.1.4.1.12 | Gauge32 | read-only | current |
| frsldPvcSmplDataOfferedE OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. If it is the case that the high capacity counters are also used, this MUST report the value of the lower 32 bits of the CounterBasedGauge64 value of frsldPvcSmplHCDataOfferedE. | 1.3.6.1.2.1.95.1.4.1.13 | Gauge32 | read-only | current |
| frsldPvcSmplHCFrDeliveredC OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. This object is a 64-bit version of frsldPvcSmplFrDeliveredC. | 1.3.6.1.2.1.95.1.4.1.14 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCFrDeliveredE OBJECT-TYPE The number of frames that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR during this interval. This object is a 64-bit version of frsldPvcSmpl- FrDeliveredE. | 1.3.6.1.2.1.95.1.4.1.15 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCFrOfferedC OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. This object is a 64-bit version of frsldPvcSmplFrOfferedC. | 1.3.6.1.2.1.95.1.4.1.16 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCFrOfferedE OBJECT-TYPE The number of frames that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. This object is a 64-bit version of frsldPvcSmplFrOfferedE. | 1.3.6.1.2.1.95.1.4.1.17 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCDataDeliveredC OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent within CIR during this interval. This value is a 64-bit version of frsldPvcSmplDataDeliveredC. | 1.3.6.1.2.1.95.1.4.1.18 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCDataDeliveredE OBJECT-TYPE The number of octets that were received at frsldPvcCtrlReceiveRP and determined to have been sent in excess of the CIR during this interval. This value is a 64-bit version of frsldPvcSmplData- DeliveredE. | 1.3.6.1.2.1.95.1.4.1.19 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCDataOfferedC OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP within CIR during this interval. This value is a 64-bit version of frsldPvcSmplDataOfferedC. | 1.3.6.1.2.1.95.1.4.1.20 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplHCDataOfferedE OBJECT-TYPE The number of octets that were offered through frsldPvcCtrlTransmitRP in excess of the CIR during this interval. This object is a 64-bit version of frsldPvcSmplDataOfferedE. | 1.3.6.1.2.1.95.1.4.1.21 | CounterBasedGauge64 | read-only | current |
| frsldPvcSmplUnavailableTime OBJECT-TYPE The amount of time this PVC was declared unavailable for any reason during this interval. | 1.3.6.1.2.1.95.1.4.1.22 | TimeTicks | read-only | current |
| frsldPvcSmplUnavailables OBJECT-TYPE The number of times this PVC was declared unavailable for any reason during this interval. | 1.3.6.1.2.1.95.1.4.1.23 | Gauge32 | read-only | current |
| frsldPvcSmplStartTime OBJECT-TYPE The value of sysUpTime when this sample interval started. | 1.3.6.1.2.1.95.1.4.1.24 | TimeStamp | read-only | current |
| frsldPvcSmplEndTime OBJECT-TYPE The value of sysUpTime when this sample interval ended. No data will be reported and the row will not appear in the table until the sample has been collected. | 1.3.6.1.2.1.95.1.4.1.25 | TimeStamp | read-only | current |
| frsldCapabilities OBJECT-IDENTITY | 1.3.6.1.2.1.95.2 | |||
| frsldPvcCtrlWriteCaps OBJECT-TYPE This object specifies the write capabilities for the read-create objects of the PVC Control table. If the corresponding bit is enabled (1), the agent supports writes to that object. | 1.3.6.1.2.1.95.2.1 | Bits {frsldPvcCtrlStatus(0), frsldPvcCtrlPacketFreq(1), frsldPvcCtrlDelayFrSize(2), frsldPvcCtrlDelayType(3), frsldPvcCtrlDelayTimeOut(4), frsldPvcCtrlPurge(5), frsldPvcCtrlDeleteOnPurge(6)} | read-only | current |
| frsldSmplCtrlWriteCaps OBJECT-TYPE This object specifies the write capabilities for the read-create objects of the Sample Control table. If the corresponding bit is enabled (1), the agent supports writes to that object. | 1.3.6.1.2.1.95.2.2 | Bits {frsldSmplCtrlStatus(0), frsldSmplCtrlBuckets(1)} | read-only | current |
| frsldRPCaps OBJECT-TYPE This object specifies the reference points that the agent supports. This object allows the management application to discover which rows can be created on a specific device. | 1.3.6.1.2.1.95.2.3 | Bits {srcLocalRP(0), ingTxLocalRP(1), tpTxLocalRP(2), eqiTxLocalRP(3), eqoTxLocalRP(4), otherTxLocalRP(5), srcRemoteRP(6), ingTxRemoteRP(7), tpTxRemoteRP(8), eqiTxRemoteRP(9), eqoTxRemoteRP(10), otherTxRemoteRP(11), desLocalRP(12), ingRxLocalRP(13), tpRxLocalRP(14), eqiRxLocalRP(15), eqoRxLocalRP(16), otherRxLocalRP(17), desRemoteRP(18), ingRxRemoteRP(19), tpRxRemoteRP(20), eqiRxRemoteRP(21), eqoRxRemoteRP(22), otherRxRemoteRP(23)} | read-only | current |
| frsldMaxPvcCtrls OBJECT-TYPE The maximum number of control rows that can be created in frsldPvcCtrlTable. Sets to this object lower than the current value of frsldNumPvcCtrls should result in inconsistentValue. | 1.3.6.1.2.1.95.2.4 | Integer32 (0..2147483647) | read-write | current |
| frsldNumPvcCtrls OBJECT-TYPE The current number of rows in frsldPvcCtrlTable. | 1.3.6.1.2.1.95.2.5 | Gauge32 | read-only | current |
| frsldMaxSmplCtrls OBJECT-TYPE The maximum number of control rows that can be created in frsldSmplCtrlTable. Sets to this object lower than the current value of frsldNumSmplCtrls should result in inconsistentValue. | 1.3.6.1.2.1.95.2.6 | Integer32 (0..2147483647) | read-write | current |
| frsldNumSmplCtrls OBJECT-TYPE The current number of rows in frsldSmplCtrlTable. | 1.3.6.1.2.1.95.2.7 | Gauge32 | read-only | current |
| frsldConformance OBJECT-IDENTITY | 1.3.6.1.2.1.95.3 | |||
| frsldMIBGroups OBJECT-IDENTITY | 1.3.6.1.2.1.95.3.1 | |||
| frsldMIBCompliances OBJECT-IDENTITY | 1.3.6.1.2.1.95.3.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| frsldPvcReqCtrlGroup OBJECT-GROUP A collection of required objects providing control information applicable to a PVC which implements Service Level Definitions. | 1.3.6.1.2.1.95.3.1.1 | current |
| frsldPvcPacketGroup OBJECT-GROUP A collection of optional objects providing packet level control information applicable to a PVC which implements Service Level Definitions. | 1.3.6.1.2.1.95.3.1.2 | current |
| frsldPvcDelayCtrlGroup OBJECT-GROUP A collection of optional objects providing delay control information applicable to a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcPacketGroup and frsldPvcDelayDataGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.3 | current |
| frsldPvcSampleCtrlGroup OBJECT-GROUP A collection of optional objects providing sample control information applicable to a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcReqDataGroup and frsldPvcSampleGeneralGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.4 | current |
| frsldPvcReqDataGroup OBJECT-GROUP A collection of required objects providing data collected on a PVC which implements Service Level Definitions. | 1.3.6.1.2.1.95.3.1.5 | current |
| frsldPvcDelayDataGroup OBJECT-GROUP A collection of optional objects providing delay data collected on a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcDelayCtrlGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.6 | current |
| frsldPvcHCFrameDataGroup OBJECT-GROUP A collection of optional objects providing high capacity frame data collected on a PVC which implements Service Level Definitions. | 1.3.6.1.2.1.95.3.1.7 | current |
| frsldPvcHCOctetDataGroup OBJECT-GROUP A collection of optional objects providing high capacity octet data collected on a PVC which implements Service Level Definitions. | 1.3.6.1.2.1.95.3.1.8 | current |
| frsldPvcSampleDelayGroup OBJECT-GROUP A collection of optional objects providing delay sample data collected on a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcDelayCtrlGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.9 | current |
| frsldPvcSampleDataGroup OBJECT-GROUP A collection of optional objects providing data and frame delivery sample data collected on a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcReqDataGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.10 | current |
| frsldPvcSampleHCFrameGroup OBJECT-GROUP A collection of optional objects providing high capacity frame delivery sample data collected on a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcHCFrameDataGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.11 | current |
| frsldPvcSampleHCDataGroup OBJECT-GROUP A collection of optional objects providing high capacity data delivery sample data collected on a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcHCOctetDataGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.12 | current |
| frsldPvcSampleAvailGroup OBJECT-GROUP A collection of optional objects providing availability sample data collected on a PVC which implements Service Level Definitions. If this group is implemented, frsldPvcReqDataGroup MUST also be implemented. | 1.3.6.1.2.1.95.3.1.13 | current |
| frsldPvcSampleGeneralGroup OBJECT-GROUP A collection of optional objects providing general sample data collected on a PVC which implements Service Level Definitions. | 1.3.6.1.2.1.95.3.1.14 | current |
| frsldCapabilitiesGroup OBJECT-GROUP A collection of required objects providing capability information and control for this MIB module. | 1.3.6.1.2.1.95.3.1.15 | current |
| frsldCompliance MODULE-COMPLIANCE The compliance statement for SNMP entities which support with Frame Relay Service Level Definitions. This group defines the minimum level of support required for compliance. | 1.3.6.1.2.1.95.3.2.1 | current |