FOUNDRY-SN-POS-GROUP-MIB
- Registered at
- 1.3.6.1.4.1.1991.1.2.14
- Last updated
- 2010-06-02 00:00
- Organization
- Brocade Communications Systems, Inc.
- Revisions
- 2010-06-02 00:00, 2009-09-30 00:00
- Namespace
- extreme
- Source file
FOUNDRY-SN-POS-GROUP-MIB- Digest
sha256:7639d446552087980653f03e3d0a359e0226109dd4524bf68f63b7304bed708e
Description
Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.
Contact
Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com
Imports
| From | Symbols |
|---|---|
| FOUNDRY-SN-ROOT-MIB | router |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
FOUNDRY-SN-POS-GROUP-MIB FOUNDRY-SN-ROOT-MIB IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| POSStatus TEXTUAL-CONVENTION Status Values | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| snPOSInfo OBJECT-IDENTITY | 1.3.6.1.4.1.1991.1.2.14.1 | |||
| snPOSInfoTable OBJECT-TYPE A specific snPOSInfo group consists of a number of switch ports. | 1.3.6.1.4.1.1991.1.2.14.1.1 | not-accessible | current | |
| snPOSInfoEntry OBJECT-TYPE An entry in the snPOSInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snPOSInfoTable requires the entired sequence of the MIB Objects in each snPOSInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned. | 1.3.6.1.4.1.1991.1.2.14.1.1.1 | not-accessible | current | |
| snPOSInfoPortNum OBJECT-TYPE The port index. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only). | 1.3.6.1.4.1.1991.1.2.14.1.1.1.1 | Integer32 | read-only | current |
| snPOSIfIndex OBJECT-TYPE In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 1213 and RFC 1573. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.2 | Integer32 | read-only | current |
| snPOSDescr OBJECT-TYPE A textual string containing the slot/port information about the interface. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.3 | DisplayString | read-only | current |
| snPOSName OBJECT-TYPE Port Name string. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.4 | DisplayString (SIZE(0..255)) | read-write | current |
| snPOSInfoSpeed OBJECT-TYPE The speed configuration for a port. The values are: 155000 622000 2488000 | 1.3.6.1.4.1.1991.1.2.14.1.1.1.5 | INTEGER {s155000(1), s622000(2), other(3), s2488000(4)} | read-write | current |
| snPOSInfoAdminStatus OBJECT-TYPE The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II) | 1.3.6.1.4.1.1991.1.2.14.1.1.1.6 | INTEGER {up(1), down(2), testing(3)} | read-write | current |
| snPOSInfoLinkStatus OBJECT-TYPE The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II) | 1.3.6.1.4.1.1991.1.2.14.1.1.1.7 | INTEGER {up(1), down(2), testing(3)} | read-only | current |
| snPOSInfoClock OBJECT-TYPE Clock default internal | 1.3.6.1.4.1.1991.1.2.14.1.1.1.8 | INTEGER {internal(1), line(2)} | read-write | current |
| snPOSInfoLoopBack OBJECT-TYPE Loop back default none | 1.3.6.1.4.1.1991.1.2.14.1.1.1.9 | INTEGER {line(1), internal(2), none(3)} | read-write | current |
| snPOSInfoScrambleATM OBJECT-TYPE ATM style scrambling default off | 1.3.6.1.4.1.1991.1.2.14.1.1.1.10 | POSStatus | read-write | current |
| snPOSInfoFraming OBJECT-TYPE Framing default SONET | 1.3.6.1.4.1.1991.1.2.14.1.1.1.11 | INTEGER {sonet(1), sdh(2)} | read-write | current |
| snPOSInfoCRC OBJECT-TYPE CRC default 32 bit | 1.3.6.1.4.1.1991.1.2.14.1.1.1.12 | INTEGER {crc32bits(1), crc16bits(2)} | read-write | current |
| snPOSInfoKeepAlive OBJECT-TYPE Keep-alive default 10 | 1.3.6.1.4.1.1991.1.2.14.1.1.1.13 | INTEGER (0..32767) | read-write | current |
| snPOSInfoFlagC2 OBJECT-TYPE C2 flag | 1.3.6.1.4.1.1991.1.2.14.1.1.1.14 | INTEGER (0..255) | read-write | current |
| snPOSInfoFlagJ0 OBJECT-TYPE J0 flag | 1.3.6.1.4.1.1991.1.2.14.1.1.1.15 | INTEGER (0..255) | read-write | current |
| snPOSInfoFlagH1 OBJECT-TYPE H1 flag | 1.3.6.1.4.1.1991.1.2.14.1.1.1.16 | INTEGER (0..255) | read-write | current |
| snPOSStatsInFrames OBJECT-TYPE The total number of packets received on the interface. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.17 | Counter32 | read-only | current |
| snPOSStatsOutFrames OBJECT-TYPE The total number of packets transmitted out of the interface. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.18 | Counter32 | read-only | current |
| snPOSStatsAlignErrors OBJECT-TYPE dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.19 | Counter32 | read-only | current |
| snPOSStatsFCSErrors OBJECT-TYPE dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.20 | Counter32 | read-only | current |
| snPOSStatsFrameTooLongs OBJECT-TYPE dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.21 | Counter32 | read-only | current |
| snPOSStatsFrameTooShorts OBJECT-TYPE A count of frames received on a particular interface that below the minimum permitted frame size. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.22 | Counter32 | read-only | current |
| snPOSStatsInDiscard OBJECT-TYPE The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.23 | Counter32 | read-only | current |
| snPOSStatsOutDiscard OBJECT-TYPE The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.24 | Counter32 | read-only | current |
| snPOSInOctets OBJECT-TYPE The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.25 | OCTET STRING (SIZE(8)) | read-only | current |
| snPOSOutOctets OBJECT-TYPE The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.26 | OCTET STRING (SIZE(8)) | read-only | current |
| snPOSStatsInBitsPerSec OBJECT-TYPE The number of bits per second received on the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.27 | Gauge32 | read-only | current |
| snPOSStatsOutBitsPerSec OBJECT-TYPE The number of bits per second transmitted out of the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.28 | Gauge32 | read-only | current |
| snPOSStatsInPktsPerSec OBJECT-TYPE The number of packets per second received on the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.29 | Gauge32 | read-only | current |
| snPOSStatsOutPktsPerSec OBJECT-TYPE The number of packets per second transmitted out of the interface over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.30 | Gauge32 | read-only | current |
| snPOSStatsInUtilization OBJECT-TYPE The input network utilization in hundredths of a percent over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.31 | INTEGER (0..10000) | read-only | current |
| snPOSStatsOutUtilization OBJECT-TYPE The output network utilization in hundredths of a percent over a 5 minutes interval. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.32 | INTEGER (0..10000) | read-only | current |
| snPOSTagType OBJECT-TYPE For tagged port, we could have multiple VLANs per port. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.33 | INTEGER {tagged(1), untagged(2)} | read-only | current |
| snPOSStatsB1 OBJECT-TYPE Section error monitoring. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.34 | Counter32 | read-only | current |
| snPOSStatsB2 OBJECT-TYPE Line error monitoring. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.35 | Counter32 | read-only | current |
| snPOSStatsB3 OBJECT-TYPE Path error monitoring. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.36 | Counter32 | read-only | current |
| snPOSStatsAIS OBJECT-TYPE Alarm indication signal. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.37 | Counter32 | read-only | current |
| snPOSStatsRDI OBJECT-TYPE Remote defect indication. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.38 | Counter32 | read-only | current |
| snPOSStatsLOP OBJECT-TYPE Loss of pointer. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.39 | Counter32 | read-only | current |
| snPOSStatsLOF OBJECT-TYPE Loss of frame. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.40 | Counter32 | read-only | current |
| snPOSStatsLOS OBJECT-TYPE Loss of signal. | 1.3.6.1.4.1.1991.1.2.14.1.1.1.41 | Counter32 | read-only | current |
| snPOSInfo2Table OBJECT-TYPE An snPOSInfo2Table consists of a number of SnPOSInfo2Entry entries | 1.3.6.1.4.1.1991.1.2.14.1.2 | not-accessible | current | |
| snPOSInfo2Entry OBJECT-TYPE An entry in the snPOSInfo2Table indicates the POS configuration on a specified port | 1.3.6.1.4.1.1991.1.2.14.1.2.1 | not-accessible | current | |
| snPOSInfo2Clock OBJECT-TYPE Clock source for the POS Interface internal(1) - internal source line (2) - clocking is derived from line | 1.3.6.1.4.1.1991.1.2.14.1.2.1.1 | INTEGER {internal(1), line(2)} | read-write | current |
| snPOSInfo2ScrambleATM OBJECT-TYPE ATM style scrambling for the POS interface disabled(0) - scrambling is disabled enabled(1) - scrambling is enabled | 1.3.6.1.4.1.1991.1.2.14.1.2.1.2 | POSStatus | read-write | current |
| snPOSInfo2CRC OBJECT-TYPE Length of Cyclic Redundnacy Check (CRC) on the POS interface crc32bits(1) - 32 bits crc16bits(2) - 16 buts | 1.3.6.1.4.1.1991.1.2.14.1.2.1.3 | INTEGER {crc32bits(1), crc16bits(2)} | read-write | current |
| snPOSInfo2KeepAlive OBJECT-TYPE Keep-alive timer for the POS interface in seconds | 1.3.6.1.4.1.1991.1.2.14.1.2.1.4 | Unsigned32 (0..65535) | read-write | current |
| snPOSInfo2FlagC2 OBJECT-TYPE C2 flag | 1.3.6.1.4.1.1991.1.2.14.1.2.1.5 | Unsigned32 (0..255) | read-write | current |
| snPOSInfo2SSM OBJECT-TYPE The S(ynchronization) S(tatus) M(essage) is sent over the SONET/SDH line to tell the other end about the quality of clock being sent over the line. t1SonetPrimaryReferenceSource(1) - SONET Primary Reference Source t1SonetTraceabilityUnknown(2} - SONET Traceability Unknown t1SonetStratum2Traceable(3) - SONET Stratum 2 Traceable t1SonetTransitNodeClock(4) - SONET Transit Node Clock t1SonetStratum3eTraceable(5) - SONET Stratum 3e Traceable t1SonetStratum3Traceable(6) - SONET Stratum 3 Traceable t1SonetMinClockTraceable(7) - SONET Minimum Clock Traceable t1SonetDus(8) - SONET Do not Use for Synchronization e1SdhTraceabilityUnknown(9) - SDH Traceability Unknown e1SdhSsmTransitNodeClockG812(10) - SDH Transit Node Clock G812 e1SdhDus(11) - SDH Do not Use for Synchronization e1SdhSsmPrimaryReferenceClockG811(12) - SDH Primary Reference Clock G811 e1SdhSsmLocalG812(13) - SDH Local G812 e1SdhSsmSyncEquipmentTimingSource(14) - SDH Synchronization Equipment Timing Source | 1.3.6.1.4.1.1991.1.2.14.1.2.1.6 | INTEGER {t1SonetPrimaryReferenceSource(1), t1SonetTraceabilityUnknown(2), t1SonetStratum2Traceable(3), t1SonetTransitNodeClock(4), t1SonetStratum3eTraceable(5), t1SonetStratum3Traceable(6), t1SonetMinClockTraceable(7), t1SonetDus(8), e1SdhTraceabilityUnknown(9), e1SdhSsmTransitNodeClockG812(10), e1SdhDus(11), e1SdhSsmPrimaryReferenceClockG811(12), e1SdhSsmLocalG812(13), e1SdhSsmSyncEquipmentTimingSource(14)} | read-write | current |
| snPOSInfo2Encapsulation OBJECT-TYPE Layer 2 encapsulation on the POS interface ppp(1) - Point to Point Protocol (PPP) hdlc(2) - Cisco High-level Data Link Control (cHDLC) | 1.3.6.1.4.1.1991.1.2.14.1.2.1.7 | INTEGER {ppp(1), hdlc(2)} | read-write | current |
| snPOSInfo2AlarmMonitoring OBJECT-TYPE Alarm Monitoring on POS interface off(0) - Alarm Monitoring is off on(1) - Alarm Montioring is on | 1.3.6.1.4.1.1991.1.2.14.1.2.1.8 | INTEGER {off(0), on(1)} | read-write | current |
| snPOSInfo2OverheadJ0ExpectedMessage OBJECT-TYPE Overhead J0 Expected Message | 1.3.6.1.4.1.1991.1.2.14.1.2.1.9 | OCTET STRING (SIZE(1)) | read-write | current |
| snPOSInfo2OverheadJ0TransmitMessage OBJECT-TYPE Overhead J0 Transmit Message | 1.3.6.1.4.1.1991.1.2.14.1.2.1.10 | OCTET STRING (SIZE(1)) | read-write | current |
| snPOSInfo2OverheadJ1ExpectedMessage OBJECT-TYPE Overhead J1 Expected Message | 1.3.6.1.4.1.1991.1.2.14.1.2.1.11 | OCTET STRING (SIZE(16..64)) | read-write | current |
| snPOSInfo2OverheadJ1MessageLength OBJECT-TYPE Overhead J1 Length of Message s16(16)...........16 bytes s64(64)............64 bytes | 1.3.6.1.4.1.1991.1.2.14.1.2.1.12 | INTEGER {s16(16), s64(64)} | read-write | current |
| snPOSInfo2OverheadJ1TransmitMessage OBJECT-TYPE Overhead J1 Transmit Message | 1.3.6.1.4.1.1991.1.2.14.1.2.1.13 | OCTET STRING (SIZE(16..64)) | read-write | current |
| snPOSPPPTable OBJECT-TYPE An snPOSPPPTable consists of a number of SnPOSPPPEntry entries | 1.3.6.1.4.1.1991.1.2.14.1.3 | not-accessible | current | |
| snPOSPPPEntry OBJECT-TYPE An entry in the snPOSPPPTable indicates the PPP control protocol status on a specified port | 1.3.6.1.4.1.1991.1.2.14.1.3.1 | not-accessible | current | |
| snPosPppLcp OBJECT-TYPE The PPP Link Control Protocol state | 1.3.6.1.4.1.1991.1.2.14.1.3.1.1 | DisplayString (SIZE(0..32)) | read-only | current |
| snPosPppIpCp OBJECT-TYPE The PPP IP Control Protocol state | 1.3.6.1.4.1.1991.1.2.14.1.3.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| snPosPppIpv6Cp OBJECT-TYPE The PPP IPv6 Control Protocol state | 1.3.6.1.4.1.1991.1.2.14.1.3.1.3 | DisplayString (SIZE(0..32)) | read-only | current |
| snPosPppOsInLcp OBJECT-TYPE The PPP OSI Network Layer Control Protocol state | 1.3.6.1.4.1.1991.1.2.14.1.3.1.4 | DisplayString (SIZE(0..32)) | read-only | current |
| snPosPppMpLscp OBJECT-TYPE The PPP MPLS Control Protocol state | 1.3.6.1.4.1.1991.1.2.14.1.3.1.5 | DisplayString (SIZE(0..32)) | read-only | current |
| snPOScHDLCTable OBJECT-TYPE An snPOScHDLCTable consists of a number of SnPOScHDLCEntry entries | 1.3.6.1.4.1.1991.1.2.14.1.4 | not-accessible | current | |
| snPOScHDLCEntry OBJECT-TYPE An entry in snPOScHDLCEntry shows the cHDLC information on a specified port | 1.3.6.1.4.1.1991.1.2.14.1.4.1 | not-accessible | current | |
| snPOScHDLCLineState OBJECT-TYPE cHDLC Line State | 1.3.6.1.4.1.1991.1.2.14.1.4.1.1 | INTEGER {down(0), up(1), unknown(2)} | read-only | current |
| snPOScHDLCInLoopback OBJECT-TYPE cHDLC in loopback | 1.3.6.1.4.1.1991.1.2.14.1.4.1.2 | INTEGER {no(0), yes(1), unknown(2)} | read-only | current |
| snPOScHDLCMySeq OBJECT-TYPE cHDLC my sequence number | 1.3.6.1.4.1.1991.1.2.14.1.4.1.3 | Unsigned32 | read-only | current |
| snPOScHDLCMySeqSeen OBJECT-TYPE cHDLC my sequence number seen | 1.3.6.1.4.1.1991.1.2.14.1.4.1.4 | Unsigned32 | read-only | current |
| snPOScHDLCPeerSeqSeen OBJECT-TYPE cHDLC peer sequence number seen | 1.3.6.1.4.1.1991.1.2.14.1.4.1.5 | Unsigned32 | read-only | current |
| snPOScHDLCUniqueSent OBJECT-TYPE cHDLC unique sent | 1.3.6.1.4.1.1991.1.2.14.1.4.1.6 | Unsigned32 | read-only | current |
| snPOScHDLCUniqueReceived OBJECT-TYPE cHDLC unique received | 1.3.6.1.4.1.1991.1.2.14.1.4.1.7 | Unsigned32 | read-only | current |