MIBs Depot

FOUNDRY-SN-POS-GROUP-MIB

Registered at
1.3.6.1.4.1.1991.1.2.14
Last updated
2010-06-02 00:00
Organization
Brocade Communications Systems, Inc.
Revisions
2010-06-02 00:00, 2009-09-30 00:00
Namespace
extreme
Source file
FOUNDRY-SN-POS-GROUP-MIB
Digest
sha256:7639d446552087980653f03e3d0a359e0226109dd4524bf68f63b7304bed708e

Description

Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.

Contact

Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com

Imports

FromSymbols
FOUNDRY-SN-ROOT-MIBrouter
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

FOUNDRY-SN-POS-GROUP-MIB
FOUNDRY-SN-ROOT-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
POSStatus
TEXTUAL-CONVENTION
Status Values
current

Objects

NameOIDSyntaxAccessStatus
snPOSInfo
OBJECT-IDENTITY
1.3.6.1.4.1.1991.1.2.14.1
snPOSInfoTable
OBJECT-TYPE
A specific snPOSInfo group consists of a number of switch ports.
1.3.6.1.4.1.1991.1.2.14.1.1not-accessiblecurrent
snPOSInfoEntry
OBJECT-TYPE
An entry in the snPOSInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snPOSInfoTable requires the entired sequence of the MIB Objects in each snPOSInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned.
1.3.6.1.4.1.1991.1.2.14.1.1.1not-accessiblecurrent
snPOSInfoPortNum
OBJECT-TYPE
The port index. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only).
1.3.6.1.4.1.1991.1.2.14.1.1.1.1Integer32read-onlycurrent
snPOSIfIndex
OBJECT-TYPE
In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 1213 and RFC 1573.
1.3.6.1.4.1.1991.1.2.14.1.1.1.2Integer32read-onlycurrent
snPOSDescr
OBJECT-TYPE
A textual string containing the slot/port information about the interface.
1.3.6.1.4.1.1991.1.2.14.1.1.1.3DisplayStringread-onlycurrent
snPOSName
OBJECT-TYPE
Port Name string.
1.3.6.1.4.1.1991.1.2.14.1.1.1.4DisplayString (SIZE(0..255))read-writecurrent
snPOSInfoSpeed
OBJECT-TYPE
The speed configuration for a port. The values are: 155000 622000 2488000
1.3.6.1.4.1.1991.1.2.14.1.1.1.5INTEGER {s155000(1), s622000(2), other(3), s2488000(4)}read-writecurrent
snPOSInfoAdminStatus
OBJECT-TYPE
The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II)
1.3.6.1.4.1.1991.1.2.14.1.1.1.6INTEGER {up(1), down(2), testing(3)}read-writecurrent
snPOSInfoLinkStatus
OBJECT-TYPE
The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II)
1.3.6.1.4.1.1991.1.2.14.1.1.1.7INTEGER {up(1), down(2), testing(3)}read-onlycurrent
snPOSInfoClock
OBJECT-TYPE
Clock default internal
1.3.6.1.4.1.1991.1.2.14.1.1.1.8INTEGER {internal(1), line(2)}read-writecurrent
snPOSInfoLoopBack
OBJECT-TYPE
Loop back default none
1.3.6.1.4.1.1991.1.2.14.1.1.1.9INTEGER {line(1), internal(2), none(3)}read-writecurrent
snPOSInfoScrambleATM
OBJECT-TYPE
ATM style scrambling default off
1.3.6.1.4.1.1991.1.2.14.1.1.1.10POSStatusread-writecurrent
snPOSInfoFraming
OBJECT-TYPE
Framing default SONET
1.3.6.1.4.1.1991.1.2.14.1.1.1.11INTEGER {sonet(1), sdh(2)}read-writecurrent
snPOSInfoCRC
OBJECT-TYPE
CRC default 32 bit
1.3.6.1.4.1.1991.1.2.14.1.1.1.12INTEGER {crc32bits(1), crc16bits(2)}read-writecurrent
snPOSInfoKeepAlive
OBJECT-TYPE
Keep-alive default 10
1.3.6.1.4.1.1991.1.2.14.1.1.1.13INTEGER (0..32767)read-writecurrent
snPOSInfoFlagC2
OBJECT-TYPE
C2 flag
1.3.6.1.4.1.1991.1.2.14.1.1.1.14INTEGER (0..255)read-writecurrent
snPOSInfoFlagJ0
OBJECT-TYPE
J0 flag
1.3.6.1.4.1.1991.1.2.14.1.1.1.15INTEGER (0..255)read-writecurrent
snPOSInfoFlagH1
OBJECT-TYPE
H1 flag
1.3.6.1.4.1.1991.1.2.14.1.1.1.16INTEGER (0..255)read-writecurrent
snPOSStatsInFrames
OBJECT-TYPE
The total number of packets received on the interface.
1.3.6.1.4.1.1991.1.2.14.1.1.1.17Counter32read-onlycurrent
snPOSStatsOutFrames
OBJECT-TYPE
The total number of packets transmitted out of the interface.
1.3.6.1.4.1.1991.1.2.14.1.1.1.18Counter32read-onlycurrent
snPOSStatsAlignErrors
OBJECT-TYPE
dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.
1.3.6.1.4.1.1991.1.2.14.1.1.1.19Counter32read-onlycurrent
snPOSStatsFCSErrors
OBJECT-TYPE
dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.
1.3.6.1.4.1.1991.1.2.14.1.1.1.20Counter32read-onlycurrent
snPOSStatsFrameTooLongs
OBJECT-TYPE
dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.
1.3.6.1.4.1.1991.1.2.14.1.1.1.21Counter32read-onlycurrent
snPOSStatsFrameTooShorts
OBJECT-TYPE
A count of frames received on a particular interface that below the minimum permitted frame size.
1.3.6.1.4.1.1991.1.2.14.1.1.1.22Counter32read-onlycurrent
snPOSStatsInDiscard
OBJECT-TYPE
The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
1.3.6.1.4.1.1991.1.2.14.1.1.1.23Counter32read-onlycurrent
snPOSStatsOutDiscard
OBJECT-TYPE
The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space.
1.3.6.1.4.1.1991.1.2.14.1.1.1.24Counter32read-onlycurrent
snPOSInOctets
OBJECT-TYPE
The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order.
1.3.6.1.4.1.1991.1.2.14.1.1.1.25OCTET STRING (SIZE(8))read-onlycurrent
snPOSOutOctets
OBJECT-TYPE
The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order.
1.3.6.1.4.1.1991.1.2.14.1.1.1.26OCTET STRING (SIZE(8))read-onlycurrent
snPOSStatsInBitsPerSec
OBJECT-TYPE
The number of bits per second received on the interface over a 5 minutes interval.
1.3.6.1.4.1.1991.1.2.14.1.1.1.27Gauge32read-onlycurrent
snPOSStatsOutBitsPerSec
OBJECT-TYPE
The number of bits per second transmitted out of the interface over a 5 minutes interval.
1.3.6.1.4.1.1991.1.2.14.1.1.1.28Gauge32read-onlycurrent
snPOSStatsInPktsPerSec
OBJECT-TYPE
The number of packets per second received on the interface over a 5 minutes interval.
1.3.6.1.4.1.1991.1.2.14.1.1.1.29Gauge32read-onlycurrent
snPOSStatsOutPktsPerSec
OBJECT-TYPE
The number of packets per second transmitted out of the interface over a 5 minutes interval.
1.3.6.1.4.1.1991.1.2.14.1.1.1.30Gauge32read-onlycurrent
snPOSStatsInUtilization
OBJECT-TYPE
The input network utilization in hundredths of a percent over a 5 minutes interval.
1.3.6.1.4.1.1991.1.2.14.1.1.1.31INTEGER (0..10000)read-onlycurrent
snPOSStatsOutUtilization
OBJECT-TYPE
The output network utilization in hundredths of a percent over a 5 minutes interval.
1.3.6.1.4.1.1991.1.2.14.1.1.1.32INTEGER (0..10000)read-onlycurrent
snPOSTagType
OBJECT-TYPE
For tagged port, we could have multiple VLANs per port.
1.3.6.1.4.1.1991.1.2.14.1.1.1.33INTEGER {tagged(1), untagged(2)}read-onlycurrent
snPOSStatsB1
OBJECT-TYPE
Section error monitoring.
1.3.6.1.4.1.1991.1.2.14.1.1.1.34Counter32read-onlycurrent
snPOSStatsB2
OBJECT-TYPE
Line error monitoring.
1.3.6.1.4.1.1991.1.2.14.1.1.1.35Counter32read-onlycurrent
snPOSStatsB3
OBJECT-TYPE
Path error monitoring.
1.3.6.1.4.1.1991.1.2.14.1.1.1.36Counter32read-onlycurrent
snPOSStatsAIS
OBJECT-TYPE
Alarm indication signal.
1.3.6.1.4.1.1991.1.2.14.1.1.1.37Counter32read-onlycurrent
snPOSStatsRDI
OBJECT-TYPE
Remote defect indication.
1.3.6.1.4.1.1991.1.2.14.1.1.1.38Counter32read-onlycurrent
snPOSStatsLOP
OBJECT-TYPE
Loss of pointer.
1.3.6.1.4.1.1991.1.2.14.1.1.1.39Counter32read-onlycurrent
snPOSStatsLOF
OBJECT-TYPE
Loss of frame.
1.3.6.1.4.1.1991.1.2.14.1.1.1.40Counter32read-onlycurrent
snPOSStatsLOS
OBJECT-TYPE
Loss of signal.
1.3.6.1.4.1.1991.1.2.14.1.1.1.41Counter32read-onlycurrent
snPOSInfo2Table
OBJECT-TYPE
An snPOSInfo2Table consists of a number of SnPOSInfo2Entry entries
1.3.6.1.4.1.1991.1.2.14.1.2not-accessiblecurrent
snPOSInfo2Entry
OBJECT-TYPE
An entry in the snPOSInfo2Table indicates the POS configuration on a specified port
1.3.6.1.4.1.1991.1.2.14.1.2.1not-accessiblecurrent
snPOSInfo2Clock
OBJECT-TYPE
Clock source for the POS Interface internal(1) - internal source line (2) - clocking is derived from line
1.3.6.1.4.1.1991.1.2.14.1.2.1.1INTEGER {internal(1), line(2)}read-writecurrent
snPOSInfo2ScrambleATM
OBJECT-TYPE
ATM style scrambling for the POS interface disabled(0) - scrambling is disabled enabled(1) - scrambling is enabled
1.3.6.1.4.1.1991.1.2.14.1.2.1.2POSStatusread-writecurrent
snPOSInfo2CRC
OBJECT-TYPE
Length of Cyclic Redundnacy Check (CRC) on the POS interface crc32bits(1) - 32 bits crc16bits(2) - 16 buts
1.3.6.1.4.1.1991.1.2.14.1.2.1.3INTEGER {crc32bits(1), crc16bits(2)}read-writecurrent
snPOSInfo2KeepAlive
OBJECT-TYPE
Keep-alive timer for the POS interface in seconds
1.3.6.1.4.1.1991.1.2.14.1.2.1.4Unsigned32 (0..65535)read-writecurrent
snPOSInfo2FlagC2
OBJECT-TYPE
C2 flag
1.3.6.1.4.1.1991.1.2.14.1.2.1.5Unsigned32 (0..255)read-writecurrent
snPOSInfo2SSM
OBJECT-TYPE
The S(ynchronization) S(tatus) M(essage) is sent over the SONET/SDH line to tell the other end about the quality of clock being sent over the line. t1SonetPrimaryReferenceSource(1) - SONET Primary Reference Source t1SonetTraceabilityUnknown(2} - SONET Traceability Unknown t1SonetStratum2Traceable(3) - SONET Stratum 2 Traceable t1SonetTransitNodeClock(4) - SONET Transit Node Clock t1SonetStratum3eTraceable(5) - SONET Stratum 3e Traceable t1SonetStratum3Traceable(6) - SONET Stratum 3 Traceable t1SonetMinClockTraceable(7) - SONET Minimum Clock Traceable t1SonetDus(8) - SONET Do not Use for Synchronization e1SdhTraceabilityUnknown(9) - SDH Traceability Unknown e1SdhSsmTransitNodeClockG812(10) - SDH Transit Node Clock G812 e1SdhDus(11) - SDH Do not Use for Synchronization e1SdhSsmPrimaryReferenceClockG811(12) - SDH Primary Reference Clock G811 e1SdhSsmLocalG812(13) - SDH Local G812 e1SdhSsmSyncEquipmentTimingSource(14) - SDH Synchronization Equipment Timing Source
1.3.6.1.4.1.1991.1.2.14.1.2.1.6INTEGER {t1SonetPrimaryReferenceSource(1), t1SonetTraceabilityUnknown(2), t1SonetStratum2Traceable(3), t1SonetTransitNodeClock(4), t1SonetStratum3eTraceable(5), t1SonetStratum3Traceable(6), t1SonetMinClockTraceable(7), t1SonetDus(8), e1SdhTraceabilityUnknown(9), e1SdhSsmTransitNodeClockG812(10), e1SdhDus(11), e1SdhSsmPrimaryReferenceClockG811(12), e1SdhSsmLocalG812(13), e1SdhSsmSyncEquipmentTimingSource(14)}read-writecurrent
snPOSInfo2Encapsulation
OBJECT-TYPE
Layer 2 encapsulation on the POS interface ppp(1) - Point to Point Protocol (PPP) hdlc(2) - Cisco High-level Data Link Control (cHDLC)
1.3.6.1.4.1.1991.1.2.14.1.2.1.7INTEGER {ppp(1), hdlc(2)}read-writecurrent
snPOSInfo2AlarmMonitoring
OBJECT-TYPE
Alarm Monitoring on POS interface off(0) - Alarm Monitoring is off on(1) - Alarm Montioring is on
1.3.6.1.4.1.1991.1.2.14.1.2.1.8INTEGER {off(0), on(1)}read-writecurrent
snPOSInfo2OverheadJ0ExpectedMessage
OBJECT-TYPE
Overhead J0 Expected Message
1.3.6.1.4.1.1991.1.2.14.1.2.1.9OCTET STRING (SIZE(1))read-writecurrent
snPOSInfo2OverheadJ0TransmitMessage
OBJECT-TYPE
Overhead J0 Transmit Message
1.3.6.1.4.1.1991.1.2.14.1.2.1.10OCTET STRING (SIZE(1))read-writecurrent
snPOSInfo2OverheadJ1ExpectedMessage
OBJECT-TYPE
Overhead J1 Expected Message
1.3.6.1.4.1.1991.1.2.14.1.2.1.11OCTET STRING (SIZE(16..64))read-writecurrent
snPOSInfo2OverheadJ1MessageLength
OBJECT-TYPE
Overhead J1 Length of Message s16(16)...........16 bytes s64(64)............64 bytes
1.3.6.1.4.1.1991.1.2.14.1.2.1.12INTEGER {s16(16), s64(64)}read-writecurrent
snPOSInfo2OverheadJ1TransmitMessage
OBJECT-TYPE
Overhead J1 Transmit Message
1.3.6.1.4.1.1991.1.2.14.1.2.1.13OCTET STRING (SIZE(16..64))read-writecurrent
snPOSPPPTable
OBJECT-TYPE
An snPOSPPPTable consists of a number of SnPOSPPPEntry entries
1.3.6.1.4.1.1991.1.2.14.1.3not-accessiblecurrent
snPOSPPPEntry
OBJECT-TYPE
An entry in the snPOSPPPTable indicates the PPP control protocol status on a specified port
1.3.6.1.4.1.1991.1.2.14.1.3.1not-accessiblecurrent
snPosPppLcp
OBJECT-TYPE
The PPP Link Control Protocol state
1.3.6.1.4.1.1991.1.2.14.1.3.1.1DisplayString (SIZE(0..32))read-onlycurrent
snPosPppIpCp
OBJECT-TYPE
The PPP IP Control Protocol state
1.3.6.1.4.1.1991.1.2.14.1.3.1.2DisplayString (SIZE(0..32))read-onlycurrent
snPosPppIpv6Cp
OBJECT-TYPE
The PPP IPv6 Control Protocol state
1.3.6.1.4.1.1991.1.2.14.1.3.1.3DisplayString (SIZE(0..32))read-onlycurrent
snPosPppOsInLcp
OBJECT-TYPE
The PPP OSI Network Layer Control Protocol state
1.3.6.1.4.1.1991.1.2.14.1.3.1.4DisplayString (SIZE(0..32))read-onlycurrent
snPosPppMpLscp
OBJECT-TYPE
The PPP MPLS Control Protocol state
1.3.6.1.4.1.1991.1.2.14.1.3.1.5DisplayString (SIZE(0..32))read-onlycurrent
snPOScHDLCTable
OBJECT-TYPE
An snPOScHDLCTable consists of a number of SnPOScHDLCEntry entries
1.3.6.1.4.1.1991.1.2.14.1.4not-accessiblecurrent
snPOScHDLCEntry
OBJECT-TYPE
An entry in snPOScHDLCEntry shows the cHDLC information on a specified port
1.3.6.1.4.1.1991.1.2.14.1.4.1not-accessiblecurrent
snPOScHDLCLineState
OBJECT-TYPE
cHDLC Line State
1.3.6.1.4.1.1991.1.2.14.1.4.1.1INTEGER {down(0), up(1), unknown(2)}read-onlycurrent
snPOScHDLCInLoopback
OBJECT-TYPE
cHDLC in loopback
1.3.6.1.4.1.1991.1.2.14.1.4.1.2INTEGER {no(0), yes(1), unknown(2)}read-onlycurrent
snPOScHDLCMySeq
OBJECT-TYPE
cHDLC my sequence number
1.3.6.1.4.1.1991.1.2.14.1.4.1.3Unsigned32read-onlycurrent
snPOScHDLCMySeqSeen
OBJECT-TYPE
cHDLC my sequence number seen
1.3.6.1.4.1.1991.1.2.14.1.4.1.4Unsigned32read-onlycurrent
snPOScHDLCPeerSeqSeen
OBJECT-TYPE
cHDLC peer sequence number seen
1.3.6.1.4.1.1991.1.2.14.1.4.1.5Unsigned32read-onlycurrent
snPOScHDLCUniqueSent
OBJECT-TYPE
cHDLC unique sent
1.3.6.1.4.1.1991.1.2.14.1.4.1.6Unsigned32read-onlycurrent
snPOScHDLCUniqueReceived
OBJECT-TYPE
cHDLC unique received
1.3.6.1.4.1.1991.1.2.14.1.4.1.7Unsigned32read-onlycurrent