MIBs Depot

FOUNDRY-POE-MIB

Last updated
2010-06-02 00:00
Organization
Brocade Communications Systems, Inc.
Revisions
2010-06-02 00:00, 2009-09-30 00:00, 2009-04-03 00:00
Namespace
extreme
Source file
FOUNDRY-POE-MIB
Digest
sha256:68a16c2c579ce758df41a74ec2448d8636c07fd47d7b0313ee0bbbba45babf41

Description

The Brocade proprietary MIB module for Power Over Ethernet(PoE) It has PoE port and module configuring information. Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.

Contact

Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com

Imports

FromSymbols
FOUNDRY-SN-ROOT-MIBsnAgentSys
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

FOUNDRY-POE-MIB
FOUNDRY-SN-ROOT-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
snAgentPoeGbl
OBJECT-IDENTITY
1.3.6.1.4.1.1991.1.1.2.14.1
snAgentPoeGblPowerCapacityTotal
OBJECT-TYPE
This object shows the total inline power capacity available in the device, measured in mWatts.
1.3.6.1.4.1.1991.1.1.2.14.1.1Unsigned32read-onlycurrent
snAgentPoeGblPowerCapacityFree
OBJECT-TYPE
This object shows the inline power capacity currently available in the device which is unallocated, measured in mWatts.
1.3.6.1.4.1.1991.1.1.2.14.1.2Unsigned32read-onlycurrent
snAgentPoeGblPowerAllocationsRequestsHonored
OBJECT-TYPE
This object shows number of times the inline power allocations requests honored.
1.3.6.1.4.1.1991.1.1.2.14.1.3Unsigned32read-onlycurrent
snAgentPoePort
OBJECT-IDENTITY
1.3.6.1.4.1.1991.1.1.2.14.2
snAgentPoePortTable
OBJECT-TYPE
A table of POE port information.
1.3.6.1.4.1.1991.1.1.2.14.2.2not-accessiblecurrent
snAgentPoePortEntry
OBJECT-TYPE
A row in the POE port table.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1not-accessiblecurrent
snAgentPoePortNumber
OBJECT-TYPE
The port number in ifIndex value.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.1InterfaceIndexread-onlycurrent
snAgentPoePortControl
OBJECT-TYPE
Control inline power on/off to a port. If a port does not have inline power capability, reading this object returns 'other(1)'.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.2INTEGER {other(1), disable(2), enable(3), enableLegacyDevice(4)}read-createcurrent
snAgentPoePortWattage
OBJECT-TYPE
Adjust the inline power wattage. Valid value between 1000 to 15400(IEEE802_3AF)/30000(IEEE802_3AT). Each unit is milliwatts. This object can only be set after snSwIfInLinePowerControl has been set to 'enable(3)' or 'enableLegacyDevice(4)'. If a port does not have inline power capability, reading this object returns undefined value.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.3Integer32read-createcurrent
snAgentPoePortClass
OBJECT-TYPE
Adjust the inline power class. Valid value between 0 to 3(IEEE802_3AF)/4(IEEE802_3AT). This object can only be set after snSwIfInLinePowerControl has been set to 'enable(3)' or 'enableLegacyDevice(4)'. If a port does not have inline power capability, reading this object returns undefined value.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.4Integer32read-createcurrent
snAgentPoePortPriority
OBJECT-TYPE
Inline power allocation priority for the power device 0- Not a POE port, 1- Critical, 2- High, 3- Low, 4- Medium, 5- other.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.5INTEGER {invalid(0), critical(1), high(2), low(3), medium(4), other(5)}read-createcurrent
snAgentPoePortConsumed
OBJECT-TYPE
Inline power consumed by the port. Each unit is milliwatts.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6Integer32read-onlycurrent
snAgentPoePortType
OBJECT-TYPE
Inline Power device type 802.3af, 802.3at or Legacy device.
1.3.6.1.4.1.1991.1.1.2.14.2.2.1.7DisplayStringread-onlycurrent
snAgentPoeModule
OBJECT-IDENTITY
1.3.6.1.4.1.1991.1.1.2.14.3
snAgentPoeModuleTable
OBJECT-TYPE
A table of POE Module configuration.
1.3.6.1.4.1.1991.1.1.2.14.3.1not-accessiblecurrent
snAgentPoeModuleEntry
OBJECT-TYPE
A row in the POE Module table.
1.3.6.1.4.1.1991.1.1.2.14.3.1.1not-accessiblecurrent
snAgentPoeModuleNumber
OBJECT-TYPE
This objects talks about POE module number.
1.3.6.1.4.1.1991.1.1.2.14.3.1.1.1Unsigned32read-onlycurrent
snAgentPoeModuleBudget
OBJECT-TYPE
This objects talks about module power budget in watts.
1.3.6.1.4.1.1991.1.1.2.14.3.1.1.2Unsigned32read-createcurrent
snAgentPoeModuleMaxPDTypeSupport
OBJECT-TYPE
This object talks about the POE module type which is capable to support Power Device (PD) type ieee802.3af or ieee802.3at(also called POE plus)type. Module which support ieee802.3at can also support ieee802.3af but reverse is not true.
1.3.6.1.4.1.1991.1.1.2.14.3.1.1.3INTEGER {ieee802dot3af(0), ieee802dot3at(1)}read-onlycurrent
snAgentPoeUnit
OBJECT-IDENTITY
1.3.6.1.4.1.1991.1.1.2.14.4
snAgentPoeUnitTable
OBJECT-TYPE
A table of POE informaion for each unit. Only the unit that has POE capability appears in a table row
1.3.6.1.4.1.1991.1.1.2.14.4.1not-accessiblecurrent
snAgentPoeUnitEntry
OBJECT-TYPE
A row in the POE Unit table.
1.3.6.1.4.1.1991.1.1.2.14.4.1.1not-accessiblecurrent
snAgentPoeUnitIndex
OBJECT-TYPE
The Index to POE unit Table.
1.3.6.1.4.1.1991.1.1.2.14.4.1.1.1Unsigned32read-onlycurrent
snAgentPoeUnitPowerCapacityTotal
OBJECT-TYPE
This object shows the total inline power capacity available on that unit (device), measured in mWatts.
1.3.6.1.4.1.1991.1.1.2.14.4.1.1.2Unsigned32read-onlycurrent
snAgentPoeUnitPowerCapacityFree
OBJECT-TYPE
This object shows the inline power capacity currently available on that unit (device) which is unallocated, measured in mWatts.
1.3.6.1.4.1.1991.1.1.2.14.4.1.1.3Unsigned32read-onlycurrent
snAgentPoeUnitPowerAllocationsRequestsHonored
OBJECT-TYPE
This object shows number of times the inline power allocations requests honored on that unit (device).
1.3.6.1.4.1.1991.1.1.2.14.4.1.1.4Unsigned32read-onlycurrent