F5OS-APPLIANCE-ALERT-NOTIF-MIB
- Registered at
- 1.3.6.1.4.1.12276.1.1.1
- Last updated
- 2019-08-04 09:41
- Organization
- F5 Networks, Inc.
- Revisions
- 2019-08-04 09:41
- Namespace
- f5
- Source file
F5OS-APPLIANCE-ALERT-NOTIF-MIB- Digest
sha256:6a63cdc5d009b7fbf284c235295b5fae34c34cc6486edd1d169ba0017b02f3cf
Description
Top-level infrastructure of the F5 Networks enterprise Alert MIB tree.
Contact
postal: F5 Networks, Inc. 801 5th Ave Seattle, WA 98104 phone: (206) 272-5555 email: support@f5.com
Imports
| From | Symbols |
|---|---|
| F5-ALERT-DEF-MIB | alertDescription, alertEffect, alertSeverity, alertSource, alertTimeStamp, f5AlertNotificationGroup, f5Alerts |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
F5-ALERT-DEF-MIB F5-COMMON-SMI-MIB F5OS-APPLIANCE-ALERT-NOTIF-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Notifications
| Name | OID | Status |
|---|---|---|
| hardware_device_fault NOTIFICATION-TYPE Hardware device fault detected | 1.3.6.1.4.1.12276.1.1.1.65536 | current |
| firmware_fault NOTIFICATION-TYPE Firmware diagnostic state fault detected | 1.3.6.1.4.1.12276.1.1.1.65537 | current |
| unknown_alarm NOTIFICATION-TYPE Unregistered alarm detected | 1.3.6.1.4.1.12276.1.1.1.65538 | current |
| memory_fault NOTIFICATION-TYPE Fault in memory detected | 1.3.6.1.4.1.12276.1.1.1.65539 | current |
| drive_fault NOTIFICATION-TYPE Fault in drive detected | 1.3.6.1.4.1.12276.1.1.1.65540 | current |
| cpu_fault NOTIFICATION-TYPE CPU fault detected | 1.3.6.1.4.1.12276.1.1.1.65541 | current |
| pcie_fault NOTIFICATION-TYPE Fault in PCIe device detected | 1.3.6.1.4.1.12276.1.1.1.65542 | current |
| aom_fault NOTIFICATION-TYPE Fault detected in the AOM | 1.3.6.1.4.1.12276.1.1.1.65543 | current |
| drive_capacity_fault NOTIFICATION-TYPE Running out of drive capacity | 1.3.6.1.4.1.12276.1.1.1.65544 | current |
| power_fault NOTIFICATION-TYPE Power fault detected in hardware | 1.3.6.1.4.1.12276.1.1.1.65545 | current |
| thermal_fault NOTIFICATION-TYPE Thermal fault detected in hardware | 1.3.6.1.4.1.12276.1.1.1.65546 | current |
| drive_thermal_throttle NOTIFICATION-TYPE Drive has entered a thermal throttle condition | 1.3.6.1.4.1.12276.1.1.1.65547 | current |
| blade_thermal_fault NOTIFICATION-TYPE Thermal fault detected in blade | 1.3.6.1.4.1.12276.1.1.1.65548 | current |
| blade_hardware_fault NOTIFICATION-TYPE Hardware fault detected in blade | 1.3.6.1.4.1.12276.1.1.1.65549 | current |
| firmware_update_status NOTIFICATION-TYPE Firmware update status | 1.3.6.1.4.1.12276.1.1.1.65550 | current |
| drive_utilization NOTIFICATION-TYPE Drive utilization growth rate is high | 1.3.6.1.4.1.12276.1.1.1.65551 | current |
| service_health NOTIFICATION-TYPE Service health status | 1.3.6.1.4.1.12276.1.1.1.65552 | current |
| module_present NOTIFICATION-TYPE Change detected in appliance module presence | 1.3.6.1.4.1.12276.1.1.1.66304 | current |
| psu_fault NOTIFICATION-TYPE PSU fault detected | 1.3.6.1.4.1.12276.1.1.1.66305 | current |
| lcd_fault NOTIFICATION-TYPE Fault detected in LCD module | 1.3.6.1.4.1.12276.1.1.1.66306 | current |
| module_communication_error NOTIFICATION-TYPE Module communication error detected | 1.3.6.1.4.1.12276.1.1.1.66307 | current |
| fipsError NOTIFICATION-TYPE Crypto error identified in one or more services | 1.3.6.1.4.1.12276.1.1.1.196608 | current |
| backplane NOTIFICATION-TYPE Could not establish backplane link with one or more system controllers | 1.3.6.1.4.1.12276.1.1.1.262144 | current |
| txPwrHiAlarm NOTIFICATION-TYPE Transmitter power high alarm | 1.3.6.1.4.1.12276.1.1.1.262400 | current |
| txPwrHiWarn NOTIFICATION-TYPE Transmitter power high warning | 1.3.6.1.4.1.12276.1.1.1.262401 | current |
| txPwrLoAlarm NOTIFICATION-TYPE Transmitter power low alarm | 1.3.6.1.4.1.12276.1.1.1.262402 | current |
| txPwrLoWarn NOTIFICATION-TYPE Transmitter power low warning | 1.3.6.1.4.1.12276.1.1.1.262403 | current |
| rxPwrHiAlarm NOTIFICATION-TYPE Receiver power high alarm | 1.3.6.1.4.1.12276.1.1.1.262404 | current |
| rxPwrHiWarn NOTIFICATION-TYPE Receiver power high warning | 1.3.6.1.4.1.12276.1.1.1.262405 | current |
| rxPwrLoAlarm NOTIFICATION-TYPE Receiver power low alarm | 1.3.6.1.4.1.12276.1.1.1.262406 | current |
| rxPwrLoWarn NOTIFICATION-TYPE Receiver power low warning | 1.3.6.1.4.1.12276.1.1.1.262407 | current |
| txBiasHiAlarm NOTIFICATION-TYPE Transmitter bias high alarm | 1.3.6.1.4.1.12276.1.1.1.262408 | current |
| txBiasHiWarn NOTIFICATION-TYPE Transmitter bias high warning | 1.3.6.1.4.1.12276.1.1.1.262409 | current |
| txBiasLoAlarm NOTIFICATION-TYPE Transmitter bias low alarm | 1.3.6.1.4.1.12276.1.1.1.262410 | current |
| txBiasLoWarn NOTIFICATION-TYPE Transmitter bias low warning | 1.3.6.1.4.1.12276.1.1.1.262411 | current |
| ddmTempHiAlarm NOTIFICATION-TYPE Optic temperature high alarm | 1.3.6.1.4.1.12276.1.1.1.262412 | current |
| ddmTempHiWarn NOTIFICATION-TYPE Optic temperature high warning | 1.3.6.1.4.1.12276.1.1.1.262413 | current |
| ddmTempLoAlarm NOTIFICATION-TYPE Optic temperature low alarm | 1.3.6.1.4.1.12276.1.1.1.262414 | current |
| ddmTempLoWarn NOTIFICATION-TYPE Optic temperature low warning | 1.3.6.1.4.1.12276.1.1.1.262415 | current |
| ddmVccHiAlarm NOTIFICATION-TYPE Optic voltage high alarm | 1.3.6.1.4.1.12276.1.1.1.262416 | current |
| ddmVccHiWarn NOTIFICATION-TYPE Optic voltage high warning | 1.3.6.1.4.1.12276.1.1.1.262417 | current |
| ddmVccLoAlarm NOTIFICATION-TYPE Optic voltage low alarm | 1.3.6.1.4.1.12276.1.1.1.262418 | current |
| ddmVccLoWarn NOTIFICATION-TYPE Optic voltage low warning | 1.3.6.1.4.1.12276.1.1.1.262419 | current |
| core_dump NOTIFICATION-TYPE Detected process crash on the system | 1.3.6.1.4.1.12276.1.1.1.327680 | current |
| raidEvent NOTIFICATION-TYPE Notification of raid event | 1.3.6.1.4.1.12276.1.1.1.393216 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| f5AlertsNotifyGroup NOTIFICATION-GROUP The notifications related to the operation of the F5 System. | 1.3.6.1.4.1.12276.1.1.0.3.1 | current |