MIBs Depot

F5OS-APPLIANCE-ALERT-NOTIF-MIB

Registered at
1.3.6.1.4.1.12276.1.1.1
Last updated
2019-08-04 09:41
Organization
F5 Networks, Inc.
Revisions
2019-08-04 09:41
Namespace
f5
Source file
F5OS-APPLIANCE-ALERT-NOTIF-MIB
Digest
sha256:6a63cdc5d009b7fbf284c235295b5fae34c34cc6486edd1d169ba0017b02f3cf

Description

Top-level infrastructure of the F5 Networks enterprise Alert MIB tree.

Contact

postal: F5 Networks, Inc. 801 5th Ave Seattle, WA 98104 phone: (206) 272-5555 email: support@f5.com

Imports

FromSymbols
F5-ALERT-DEF-MIBalertDescription, alertEffect, alertSeverity, alertSource, alertTimeStamp, f5AlertNotificationGroup, f5Alerts
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

F5-ALERT-DEF-MIB
F5-COMMON-SMI-MIB
F5OS-APPLIANCE-ALERT-NOTIF-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Notifications

NameOIDStatus
hardware_device_fault
NOTIFICATION-TYPE
Hardware device fault detected
1.3.6.1.4.1.12276.1.1.1.65536current
firmware_fault
NOTIFICATION-TYPE
Firmware diagnostic state fault detected
1.3.6.1.4.1.12276.1.1.1.65537current
unknown_alarm
NOTIFICATION-TYPE
Unregistered alarm detected
1.3.6.1.4.1.12276.1.1.1.65538current
memory_fault
NOTIFICATION-TYPE
Fault in memory detected
1.3.6.1.4.1.12276.1.1.1.65539current
drive_fault
NOTIFICATION-TYPE
Fault in drive detected
1.3.6.1.4.1.12276.1.1.1.65540current
cpu_fault
NOTIFICATION-TYPE
CPU fault detected
1.3.6.1.4.1.12276.1.1.1.65541current
pcie_fault
NOTIFICATION-TYPE
Fault in PCIe device detected
1.3.6.1.4.1.12276.1.1.1.65542current
aom_fault
NOTIFICATION-TYPE
Fault detected in the AOM
1.3.6.1.4.1.12276.1.1.1.65543current
drive_capacity_fault
NOTIFICATION-TYPE
Running out of drive capacity
1.3.6.1.4.1.12276.1.1.1.65544current
power_fault
NOTIFICATION-TYPE
Power fault detected in hardware
1.3.6.1.4.1.12276.1.1.1.65545current
thermal_fault
NOTIFICATION-TYPE
Thermal fault detected in hardware
1.3.6.1.4.1.12276.1.1.1.65546current
drive_thermal_throttle
NOTIFICATION-TYPE
Drive has entered a thermal throttle condition
1.3.6.1.4.1.12276.1.1.1.65547current
blade_thermal_fault
NOTIFICATION-TYPE
Thermal fault detected in blade
1.3.6.1.4.1.12276.1.1.1.65548current
blade_hardware_fault
NOTIFICATION-TYPE
Hardware fault detected in blade
1.3.6.1.4.1.12276.1.1.1.65549current
firmware_update_status
NOTIFICATION-TYPE
Firmware update status
1.3.6.1.4.1.12276.1.1.1.65550current
drive_utilization
NOTIFICATION-TYPE
Drive utilization growth rate is high
1.3.6.1.4.1.12276.1.1.1.65551current
service_health
NOTIFICATION-TYPE
Service health status
1.3.6.1.4.1.12276.1.1.1.65552current
module_present
NOTIFICATION-TYPE
Change detected in appliance module presence
1.3.6.1.4.1.12276.1.1.1.66304current
psu_fault
NOTIFICATION-TYPE
PSU fault detected
1.3.6.1.4.1.12276.1.1.1.66305current
lcd_fault
NOTIFICATION-TYPE
Fault detected in LCD module
1.3.6.1.4.1.12276.1.1.1.66306current
module_communication_error
NOTIFICATION-TYPE
Module communication error detected
1.3.6.1.4.1.12276.1.1.1.66307current
fipsError
NOTIFICATION-TYPE
Crypto error identified in one or more services
1.3.6.1.4.1.12276.1.1.1.196608current
backplane
NOTIFICATION-TYPE
Could not establish backplane link with one or more system controllers
1.3.6.1.4.1.12276.1.1.1.262144current
txPwrHiAlarm
NOTIFICATION-TYPE
Transmitter power high alarm
1.3.6.1.4.1.12276.1.1.1.262400current
txPwrHiWarn
NOTIFICATION-TYPE
Transmitter power high warning
1.3.6.1.4.1.12276.1.1.1.262401current
txPwrLoAlarm
NOTIFICATION-TYPE
Transmitter power low alarm
1.3.6.1.4.1.12276.1.1.1.262402current
txPwrLoWarn
NOTIFICATION-TYPE
Transmitter power low warning
1.3.6.1.4.1.12276.1.1.1.262403current
rxPwrHiAlarm
NOTIFICATION-TYPE
Receiver power high alarm
1.3.6.1.4.1.12276.1.1.1.262404current
rxPwrHiWarn
NOTIFICATION-TYPE
Receiver power high warning
1.3.6.1.4.1.12276.1.1.1.262405current
rxPwrLoAlarm
NOTIFICATION-TYPE
Receiver power low alarm
1.3.6.1.4.1.12276.1.1.1.262406current
rxPwrLoWarn
NOTIFICATION-TYPE
Receiver power low warning
1.3.6.1.4.1.12276.1.1.1.262407current
txBiasHiAlarm
NOTIFICATION-TYPE
Transmitter bias high alarm
1.3.6.1.4.1.12276.1.1.1.262408current
txBiasHiWarn
NOTIFICATION-TYPE
Transmitter bias high warning
1.3.6.1.4.1.12276.1.1.1.262409current
txBiasLoAlarm
NOTIFICATION-TYPE
Transmitter bias low alarm
1.3.6.1.4.1.12276.1.1.1.262410current
txBiasLoWarn
NOTIFICATION-TYPE
Transmitter bias low warning
1.3.6.1.4.1.12276.1.1.1.262411current
ddmTempHiAlarm
NOTIFICATION-TYPE
Optic temperature high alarm
1.3.6.1.4.1.12276.1.1.1.262412current
ddmTempHiWarn
NOTIFICATION-TYPE
Optic temperature high warning
1.3.6.1.4.1.12276.1.1.1.262413current
ddmTempLoAlarm
NOTIFICATION-TYPE
Optic temperature low alarm
1.3.6.1.4.1.12276.1.1.1.262414current
ddmTempLoWarn
NOTIFICATION-TYPE
Optic temperature low warning
1.3.6.1.4.1.12276.1.1.1.262415current
ddmVccHiAlarm
NOTIFICATION-TYPE
Optic voltage high alarm
1.3.6.1.4.1.12276.1.1.1.262416current
ddmVccHiWarn
NOTIFICATION-TYPE
Optic voltage high warning
1.3.6.1.4.1.12276.1.1.1.262417current
ddmVccLoAlarm
NOTIFICATION-TYPE
Optic voltage low alarm
1.3.6.1.4.1.12276.1.1.1.262418current
ddmVccLoWarn
NOTIFICATION-TYPE
Optic voltage low warning
1.3.6.1.4.1.12276.1.1.1.262419current
core_dump
NOTIFICATION-TYPE
Detected process crash on the system
1.3.6.1.4.1.12276.1.1.1.327680current
raidEvent
NOTIFICATION-TYPE
Notification of raid event
1.3.6.1.4.1.12276.1.1.1.393216current

Conformance

NameOIDStatus
f5AlertsNotifyGroup
NOTIFICATION-GROUP
The notifications related to the operation of the F5 System.
1.3.6.1.4.1.12276.1.1.0.3.1current