EdgeSwitch-BOXSERVICES-PRIVATE-MIB
- Registered at
- 1.3.6.1.4.1.4413.1.1.43
- Last updated
- 2011-01-26 00:00
- Organization
- Broadcom Inc
- Revisions
- 2011-01-26 00:00, 2008-02-22 00:00
- Namespace
- edgeswitch
- Source file
EdgeSwitch-BOXSERVICES-PRIVATE-MIB- Digest
sha256:b5916fa0508548ca86ec18985d8dc0cc235be69dcb9cc5426c573559f21e6e96
Description
The Ubiquiti Private MIB for EdgeSwitch Box Services Feature.
Imports
| From | Symbols |
|---|---|
| EdgeSwitch-REF-MIB | fastPath |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
EdgeSwitch-BOXSERVICES-PRIVATE-MIB EdgeSwitch-REF-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| BoxsTemperatureStatus TEXTUAL-CONVENTION The temperature state | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| fastPathBoxServicesTraps OBJECT-IDENTITY | 1.3.6.1.4.1.4413.1.1.43.0 | |||
| boxServicesGroup OBJECT-IDENTITY | 1.3.6.1.4.1.4413.1.1.43.1 | |||
| boxServicesNormalTempRangeMin OBJECT-TYPE Lower boundary of normal temperature range. | 1.3.6.1.4.1.4413.1.1.43.1.1 | Integer32 (-100..100) | read-write | current |
| boxServicesNormalTempRangeMax OBJECT-TYPE Upper boundary of normal temperature range. | 1.3.6.1.4.1.4413.1.1.43.1.2 | Integer32 (-100..100) | read-write | current |
| boxServicesTemperatureTrapEnable OBJECT-TYPE Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range | 1.3.6.1.4.1.4413.1.1.43.1.3 | INTEGER {enable(1), disable(2)} | read-write | current |
| boxServicesPSMStateTrapEnable OBJECT-TYPE Enable or disable Power Supply Module state change trap. | 1.3.6.1.4.1.4413.1.1.43.1.4 | INTEGER {enable(1), disable(2)} | read-write | current |
| boxServicesFanStateTrapEnable OBJECT-TYPE Enable or disable Fan state change trap. | 1.3.6.1.4.1.4413.1.1.43.1.5 | INTEGER {enable(1), disable(2)} | read-write | current |
| boxServicesFansTable OBJECT-TYPE Fan | 1.3.6.1.4.1.4413.1.1.43.1.6 | not-accessible | current | |
| boxServicesFansEntry OBJECT-TYPE Box Services Fan Entry | 1.3.6.1.4.1.4413.1.1.43.1.6.1 | not-accessible | current | |
| boxServicesFansIndex OBJECT-TYPE Unique index of fan table entry | 1.3.6.1.4.1.4413.1.1.43.1.6.1.1 | Integer32 (0..2147483647) | read-only | current |
| boxServicesFanItemType OBJECT-TYPE The type of fan | 1.3.6.1.4.1.4413.1.1.43.1.6.1.2 | INTEGER {fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6)} | read-only | current |
| boxServicesFanItemState OBJECT-TYPE The status of fan. nopower(4) - This state means the fan is present but no AC is connected. | 1.3.6.1.4.1.4413.1.1.43.1.6.1.3 | INTEGER {notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7)} | read-only | current |
| boxServicesFanSpeed OBJECT-TYPE The speed of fan | 1.3.6.1.4.1.4413.1.1.43.1.6.1.4 | OCTET STRING (SIZE(13)) | read-only | current |
| boxServicesFanDutyLevel OBJECT-TYPE The duty level of fan, in percents | 1.3.6.1.4.1.4413.1.1.43.1.6.1.5 | OCTET STRING (SIZE(13)) | read-only | current |
| boxServicesFanUnitIndex OBJECT-TYPE Unit index for an entry in the Box Services Fan Table | 1.3.6.1.4.1.4413.1.1.43.1.6.1.6 | Unsigned32 | read-only | current |
| boxServicesPowSuppliesTable OBJECT-TYPE Power supply | 1.3.6.1.4.1.4413.1.1.43.1.7 | not-accessible | current | |
| boxServicesPowSuppliesEntry OBJECT-TYPE Box Services Power Supply Entry | 1.3.6.1.4.1.4413.1.1.43.1.7.1 | not-accessible | current | |
| boxServicesPowSupplyIndex OBJECT-TYPE Unique index of power supply table entry | 1.3.6.1.4.1.4413.1.1.43.1.7.1.1 | Integer32 (0..2147483647) | read-only | current |
| boxServicesPowSupplyItemType OBJECT-TYPE The type of power supply | 1.3.6.1.4.1.4413.1.1.43.1.7.1.2 | INTEGER {fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6)} | read-only | current |
| boxServicesPowSupplyItemState OBJECT-TYPE The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected. incompatible(7) - This state is possible on boards capable of pluggable Power supplies | 1.3.6.1.4.1.4413.1.1.43.1.7.1.3 | INTEGER {notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7)} | read-only | current |
| boxServicesPowerSuppUnitIndex OBJECT-TYPE Unit index for an entry in the Box Services Power Supply Table | 1.3.6.1.4.1.4413.1.1.43.1.7.1.4 | Unsigned32 | read-only | current |
| boxServicesTempSensorsTable OBJECT-TYPE Temperature sensor | 1.3.6.1.4.1.4413.1.1.43.1.8 | not-accessible | current | |
| boxServicesTempSensorsEntry OBJECT-TYPE Box Services Temperature Sensor Entry | 1.3.6.1.4.1.4413.1.1.43.1.8.1 | not-accessible | current | |
| boxServicesUnitIndex OBJECT-TYPE Unit index for an entry in the Box Services Temperature Sensor Table | 1.3.6.1.4.1.4413.1.1.43.1.8.1.1 | Unsigned32 | read-only | current |
| boxServicesTempSensorIndex OBJECT-TYPE Unique index of temperature sensor table entry | 1.3.6.1.4.1.4413.1.1.43.1.8.1.2 | Unsigned32 | read-only | current |
| boxServicesTempSensorType OBJECT-TYPE The type of temperature sensor | 1.3.6.1.4.1.4413.1.1.43.1.8.1.3 | INTEGER {fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6)} | read-only | current |
| boxServicesTempSensorState OBJECT-TYPE The state of temperature sensor | 1.3.6.1.4.1.4413.1.1.43.1.8.1.4 | BoxsTemperatureStatus | read-only | obsolete |
| boxServicesTempSensorTemperature OBJECT-TYPE The temperature value reported by sensor | 1.3.6.1.4.1.4413.1.1.43.1.8.1.5 | Integer32 | read-only | current |
| boxServicesThermalShutdownSensor OBJECT-TYPE The number of the sensor which initiated thermal shutdown. | 1.3.6.1.4.1.4413.1.1.43.1.13 | Unsigned32 | accessible-for-notify | current |
| boxServicesThermalShutdownTemperature OBJECT-TYPE The temperature of the sensor which initiated thermal shutdown. | 1.3.6.1.4.1.4413.1.1.43.1.14 | Unsigned32 | accessible-for-notify | current |
| boxServicesTempUnitTable OBJECT-TYPE Temperature status table | 1.3.6.1.4.1.4413.1.1.43.1.15 | not-accessible | current | |
| boxServicesTempUnitEntry OBJECT-TYPE Box Services Temperature Unit Entry | 1.3.6.1.4.1.4413.1.1.43.1.15.1 | not-accessible | current | |
| boxServicesTempUnitIndex OBJECT-TYPE Unit index for an entry in the Box Services Temperature Unit Table | 1.3.6.1.4.1.4413.1.1.43.1.15.1.1 | Unsigned32 | read-only | current |
| boxServicesTempUnitState OBJECT-TYPE The temperature state of the unit | 1.3.6.1.4.1.4413.1.1.43.1.15.1.2 | BoxsTemperatureStatus | read-only | current |
| boxServicesTempUnitTemperature OBJECT-TYPE The highest temperature currently reported by any sensor on the unit | 1.3.6.1.4.1.4413.1.1.43.1.15.1.3 | Integer32 | read-only | current |
| boxServicesNotificationsGroup OBJECT-IDENTITY | 1.3.6.1.4.1.4413.1.1.43.2 | |||
| boxsItemStateChangeEvent OBJECT-TYPE This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed | 1.3.6.1.4.1.4413.1.1.43.2.1 | INTEGER {insertion(1), removal(2), becomeoperational(3), failure(4), losepower(5)} | accessible-for-notify | current |
| boxsTemperatureChangeEvent OBJECT-TYPE This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold) | 1.3.6.1.4.1.4413.1.1.43.2.2 | INTEGER {abovethreshold(1), belowthreshold(2), withinnormalrange(3)} | accessible-for-notify | current |
| boxsTemperatureStatusCurrentEvent OBJECT-TYPE This event describes the current status of a switch. | 1.3.6.1.4.1.4413.1.1.43.2.3 | BoxsTemperatureStatus | accessible-for-notify | current |
| boxsTemperatureStatusPreviousEvent OBJECT-TYPE This event describes the previous status of a switch. | 1.3.6.1.4.1.4413.1.1.43.2.4 | BoxsTemperatureStatus | accessible-for-notify | current |
| boxsLocatorLedConfigGroup OBJECT-IDENTITY | 1.3.6.1.4.1.4413.1.1.43.4 | |||
| boxsLocatorLedUnit OBJECT-TYPE Spesifies unit number where Locator LED should blink on. This is write-only value. It always returns '0' on request if the Locator Led feature is supported. | 1.3.6.1.4.1.4413.1.1.43.4.1 | INTEGER | read-write | current |
| boxsLocatorLedTime OBJECT-TYPE Indicates time period in seconds for Locator LED blinking. The range is from 20 to 3600 seconds. The dafault value is 20 seconds. This is write-only value. It always returns '0' on request if the Locator Led feature is supported. | 1.3.6.1.4.1.4413.1.1.43.4.2 | INTEGER | read-write | current |
| boxsLocatorLedEnable OBJECT-TYPE Starts the Locator LED blinking. If boxsLocatorLedUnit has not been set current(manager) unit number will be used. If boxsLocatorLedTime has not been set default value(20 seconds) will be used. This is write-only value. It always returns '0' on request if the Locator Led feature is supported. | 1.3.6.1.4.1.4413.1.1.43.4.3 | INTEGER {disable(0), enable(1)} | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| boxsFanStateChange NOTIFICATION-TYPE Trap is sent when fan state change happens. | 1.3.6.1.4.1.4413.1.1.43.0.1 | current |
| boxsPowSupplyStateChange NOTIFICATION-TYPE Trap is sent when power supply state change happens. | 1.3.6.1.4.1.4413.1.1.43.0.2 | current |
| boxsTemperatureChange NOTIFICATION-TYPE Trap is sent when temperature is changing and crossing any of the thresholds | 1.3.6.1.4.1.4413.1.1.43.0.3 | obsolete |
| boxsThermalShutdown NOTIFICATION-TYPE Trap is sent when thermal shutdown is initiated. | 1.3.6.1.4.1.4413.1.1.43.0.4 | current |
| boxsTemperatureStateChange NOTIFICATION-TYPE Trap is sent when the system temperature crosses a threshold. To avoid rapid flapping between states, a hysteresis may be applied. | 1.3.6.1.4.1.4413.1.1.43.0.5 | current |