EXTREME-POE-MIB

Registered at
1.3.6.1.4.1.1916.1.27
Last updated
1900-07-24 00:00
Organization
Extreme Networks, Inc.
Namespace
extreme
Source file
EXTREME-BASE-MIB
Digest
sha256:920ec3f1c764d83d84c3c0ad6a4d3ca2aa2e105baf75bb47bf910c2a7454dbfc

Description

Extreme Power over Ethernet MIB objects

Contact

www.extremenetworks.com

Imports

FromSymbols
EXTREME-BASE-MIBextremeAgent, extremeV2Traps
POWER-ETHERNET-MIBpethMainPseGroupIndex, pethPsePortGroupIndex, pethPsePortIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

EXTREME-BASE-MIB
EXTREME-POE-MIB
POWER-ETHERNET-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
extremePethMain
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.27.1
extremePethPseSlotTable
OBJECT-TYPE
A table of objects that provides power management capabilities per slot.
1.3.6.1.4.1.1916.1.27.1.2not-accessiblecurrent
extremePethPseSlotEntry
OBJECT-TYPE
A set of objects that display and control the power characteristics of a slot.
1.3.6.1.4.1.1916.1.27.1.2.1not-accessiblecurrent
extremePethSlotNumber
OBJECT-TYPE
Slot number. This is the same as the Group Index
1.3.6.1.4.1.1916.1.27.1.2.1.1Integer32not-accessiblecurrent
extremePethSlotPowerLimit
OBJECT-TYPE
The configured maximum amount of inline power available to slot. The operational power available to the slot is based upon other operational and configuration parameters, such as the power-supply mode and status. This number is provided by the object extremePethSlotMaxAvailPower. extremePethSlotPowerLimit may be greater than extremePethSlotMaxAvailPower, however, cannot exceed the maximum slot capacity, provided by extremePethSlotMaxCapacity
1.3.6.1.4.1.1916.1.27.1.2.1.2Integer32read-writecurrent
extremePethSlotConsumptionPower
OBJECT-TYPE
The amount of power allocated to PoE devices on the slot expressed in mWatts. The amount of power allocated to a PoE device is based upon the PoE device class and/or the port's extremePethPortViolationPrecedence setting. For example, in the default configuration of extremePethPortViolationPrecedence set to maxAdvertisedOperator(3), and the extremePethPortOperatorLimit set to 15400, a PoE device is allocated 15.4 watts.
1.3.6.1.4.1.1916.1.27.1.2.1.3Gauge32read-onlycurrent
extremePethSlotClearConnectHistory
OBJECT-TYPE
Clears the port connection history of the specified slot. Reading the value always reurns clear(2).
1.3.6.1.4.1.1916.1.27.1.2.1.4INTEGER {set(1), clear(2)}read-writecurrent
extremePethSlotReservedConsumptionPower
OBJECT-TYPE
The amount of reserved power consumed on the slot expressed in Milliwatts.
1.3.6.1.4.1.1916.1.27.1.2.1.5Gauge32read-onlycurrent
extremePethSlotCommonConsumptionPower
OBJECT-TYPE
The amount of common power allocated on the slot expressed in Milliwatts. This value is computed by the formula: extremePethSlotConsumptionPower - extremePethSlotReservedConsumptionPower.
1.3.6.1.4.1.1916.1.27.1.2.1.6Gauge32read-onlycurrent
extremePethSlotAdminEnable
OBJECT-TYPE
Controls whether inline power is provided by the slot.
1.3.6.1.4.1.1916.1.27.1.2.1.7INTEGER {enable(1), disable(2)}read-writecurrent
extremePethSlotPoeStatus
OBJECT-TYPE
Describes the status of the PoE system on the slot. initializing - PoE controller is under initialization, operational - PoE controller is operational and is ready or providing power, downloadFail - PoE controller required update and the update failed, PoE reset is required to re-update, calibrationRequired - PoE contoller is operational, however calibration is required to provide power, invalidFirmware - PoE controller contains invalid firmware, mismatchVersion - PoE controller update completed, however version mismatches expected, reboot, updating - PoE controller is being updated, invalidDevice - PoE controller detected an invalid/bad PoE device. notOperational - PoE controller is not yet operational other - PoE controller is in undefined stats.
1.3.6.1.4.1.1916.1.27.1.2.1.8INTEGER {initializing(1), operational(2), downloadFail(3), calibrationRequired(4), invalidFirmware(5), mismatchVersion(6), updating(7), invalidDevice(8), notOperational(9), other(10)}read-onlycurrent
extremePethSlotPoeResetSystem
OBJECT-TYPE
Resets the PoE system on the slot. Reading returns clear(2)
1.3.6.1.4.1.1916.1.27.1.2.1.9INTEGER {set(1), clear(2)}read-writecurrent
extremePethSlotMaxAvailPower
OBJECT-TYPE
The maximum power available to the slot expressed in Watts. The value depends on various configuration parameters and power-supply modes and status.
1.3.6.1.4.1.1916.1.27.1.2.1.10Gauge32read-onlycurrent
extremePethSlotMaxCapacity
OBJECT-TYPE
The maximum capacity of the slot expressed in Watts. This provides the hardware limitation of the slot. Actual amount of power is dependant on system status. The object extremePethSlotPowerLimit must not be greater than this amount.
1.3.6.1.4.1.1916.1.27.1.2.1.11Gauge32read-onlycurrent
extremePethSlotBackupPSU
OBJECT-TYPE
Controls the backup power supply for inline power for the slot. A system which does not allow the backup PSU to be configured will return an error upon setting.
1.3.6.1.4.1.1916.1.27.1.2.1.12INTEGER {none(1), internal(2), external(3), notApplicable(4)}read-writecurrent
extremePethSlotPSUActive
OBJECT-TYPE
Inline Power supply status indication for the slot. Indicates which PSU is currently active. In the case of a failover a none indication can occur until one of the PSU has finished powering up.
1.3.6.1.4.1.1916.1.27.1.2.1.13INTEGER {none(1), internal(2), external(3)}read-onlycurrent
extremePethSlotMeasuredPower
OBJECT-TYPE
The measured amount of power for all PoE device on the slot.
1.3.6.1.4.1.1916.1.27.1.2.1.14Gauge32read-onlycurrent
extremePethSlotMainPseIndex
OBJECT-TYPE
The index into the PethMainPseTable. Provides the mapping of the slot identifier to pethMainPseGroupIndex.
1.3.6.1.4.1.1916.1.27.1.2.1.15Integer32read-onlycurrent
extremePethPort
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.27.2
extremePethPsePortTable
OBJECT-TYPE
A table of objects that extends the standard pethPsePortTable.
1.3.6.1.4.1.1916.1.27.2.1not-accessiblecurrent
extremePethPsePortEntry
OBJECT-TYPE
A set of objects that display and control the power characteristics of a powerEthernet PSE port. This table extends the standard pethPsePortTable.
1.3.6.1.4.1.1916.1.27.2.1.1not-accessiblecurrent
extremePethPortOperatorLimit
OBJECT-TYPE
Controls individual port maximum power level.
1.3.6.1.4.1.1916.1.27.2.1.1.1Integer32 (3000..20000)read-writecurrent
extremePethPortReservedBudget
OBJECT-TYPE
Controls individual port maximum power level. Value is 0 or in the range of 3000..20000
1.3.6.1.4.1.1916.1.27.2.1.1.2Integer32 (0..20000)read-writecurrent
extremePethPortViolationPrecedence
OBJECT-TYPE
Sets the violation precedence for the specified ports. A value of advertised-class will remove/deny power in the case an 802.3af compliant PD consumes power beyond its advertised class limit. A value of operator-limit will remove/deny power should the PD consume power beyond the configured operator-limit. A value of max-class-operator will remove/deny power if the PD consumes power beyond the maximum of the detected class limit and the operator-limit. A value of none will remove/deny power in case the PD device exceeds the maximum allowable wattage according to regulatory maximum of 20 W. Default is max-class-operator which allows operation of both 802.3af compliant and legacy PDs.
1.3.6.1.4.1.1916.1.27.2.1.1.3INTEGER {advertisedClass(1), operatorLimit(2), maxAdvertisedOperator(3), none(4)}read-writecurrent
extremePethPortClearFault
OBJECT-TYPE
Clears the fault condition. Reading always returns clear(2).
1.3.6.1.4.1.1916.1.27.2.1.1.4INTEGER {set(1), clear(2)}read-writecurrent
extremePethPortResetPower
OBJECT-TYPE
Resets the power on the port. Reading always returns clear(2)
1.3.6.1.4.1.1916.1.27.2.1.1.5INTEGER {set(1), clear(2)}read-writecurrent
extremePethPortMeasuredPower
OBJECT-TYPE
The amount of power consumed on the port expressed in Milliwatts.
1.3.6.1.4.1.1916.1.27.2.1.1.6Gauge32read-onlycurrent
extremePethSystem
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.27.4
extremePethSystemAdminEnable
OBJECT-TYPE
Controls whether inline power is provided by the system.
1.3.6.1.4.1.1916.1.27.4.1INTEGER {enable(1), disable(2)}read-writecurrent
extremePethSystemDisconnectPrecedence
OBJECT-TYPE
Controls the disconnect function of power management. When the power drain exceeds the available power budget, due to a rise in power consumption after power is allocated to the ports, the PoE controller disconnects one of the ports to prevent overload on the power supply. There are two controls: Lowest-priority: next port connected causes a shutdown of the lowest priority port. Deny-port: next port is denied power, regardless of priority.
1.3.6.1.4.1.1916.1.27.4.2INTEGER {lowestPriority(1), denyPort(2)}read-writecurrent
extremePethSystemUsageThreshold
OBJECT-TYPE
The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.
1.3.6.1.4.1.1916.1.27.4.3Integer32 (1..99)read-writecurrent
extremePethSystemPowerSupplyMode
OBJECT-TYPE
Controls whether the power supply operate in redundant or load-sharing mode. Systems which do not provide redundant or load-sharing operations will return an error on setting, and notApplicable on read.
1.3.6.1.4.1.1916.1.27.4.4INTEGER {redundant(1), loadSharing(2), notApplicable(3)}read-writecurrent
extremePethSystemLegacyEnable
OBJECT-TYPE
Controls whether legacy is supported by the system. This is only supported on S300-24 stackables currently.
1.3.6.1.4.1.1916.1.27.4.5INTEGER {enable(1), disable(2)}read-writecurrent