MIBs Depot

EXTREME-CABLE-MIB

Registered at
1.3.6.1.4.1.1916.1.24
1.3.6.1.4.1.1916.4.13
Last updated
1900-07-24 00:00
Organization
Extreme Networks, Inc.
Namespace
extreme
Source file
EXTREME-BASE-MIB
Digest
sha256:920ec3f1c764d83d84c3c0ad6a4d3ca2aa2e105baf75bb47bf910c2a7454dbfc

Description

Extreme-specific Cable objects

Contact

www.extremenetworks.com

Imports

FromSymbols
EXTREME-BASE-MIBextremeAgent, extremeV2Traps, extremenetworks
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

EXTREME-BASE-MIB
EXTREME-CABLE-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
extremeDiagConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.1916.1.24.1
extremeDiagConfigTime
OBJECT-TYPE
Indicates the time at which the Diagnostics information will be collected for the ports which have Auto-Diagnostics configured. Time must be given in hh:mm:ss format where hh, mm and ss are in decimals
1.3.6.1.4.1.1916.1.24.1.1DisplayString (SIZE(16))read-writecurrent
extremeDiagConfigRoF
OBJECT-TYPE
Indicates whether a port should return to INIT state on Diagnostics Failure. If TRUE the port will be restarted even if the Diagnostics indicate a Failure. If FALSE the port will be moved to DIAG_FAIL state
1.3.6.1.4.1.1916.1.24.1.2INTEGER {true(1), false(2)}read-writecurrent
extremeDiagPortConfigTable
OBJECT-TYPE
Table, which contains the diagnostic configuration information for the ports
1.3.6.1.4.1.1916.1.24.2not-accessiblecurrent
extremeDiagPortConfigEntry
OBJECT-TYPE
Each row represents port related diagnostics configuration
1.3.6.1.4.1.1916.1.24.2.1not-accessiblecurrent
extremeDiagPortCfgPortIfIndex
OBJECT-TYPE
IfIndex of the Port for which the information in this row applies
1.3.6.1.4.1.1916.1.24.2.1.1INTEGERread-onlycurrent
extremeDiagPortCfgMode
OBJECT-TYPE
The mode of operation. The port can be configured to have either manual diagnostics or auto-diagnostics collected.
1.3.6.1.4.1.1916.1.24.2.1.2INTEGER {auto(1), manual(2)}read-onlycurrent
extremeDiagPortCfgStatus
OBJECT-TYPE
Specifies whether Diagnostics are enabled or disabled for the port. In the manual mode, enable and disable will disable the corresponding bit in the manual Diag portmask. Once the run command is given the Manual Diagnostics starts running. <diagfail> indicates the diagnostics for the port has failed. <diagfail> is a read-only value and cannot be used for setting the status of the port
1.3.6.1.4.1.1916.1.24.2.1.3INTEGER {enable(1), disable(2), run(3), diagfail(4)}read-writecurrent
extremeDiagPortDiagTable
OBJECT-TYPE
Table contains the diagnostic information for the ports
1.3.6.1.4.1.1916.1.24.3not-accessiblecurrent
extremeDiagPortDiagEntry
OBJECT-TYPE
Each row represents port related diagnostics information
1.3.6.1.4.1.1916.1.24.3.1not-accessiblecurrent
extremeDiagPortDiagPortIfIndex
OBJECT-TYPE
IfIndex of the Port for which the information in this row applies
1.3.6.1.4.1.1916.1.24.3.1.1INTEGERread-onlycurrent
extremeDiagPortDiagMode
OBJECT-TYPE
The mode of operation. The port can be configured to have either manual diagnostics or auto-diagnostics collected.
1.3.6.1.4.1.1916.1.24.3.1.2INTEGER {auto(1), manual(2)}read-onlycurrent
extremeDiagPortSpeed
OBJECT-TYPE
Specifies the speed of the port
1.3.6.1.4.1.1916.1.24.3.1.3INTEGER {speed10(1), speed100(2), speed1000(3), unknown(4)}read-onlycurrent
extremeDiagPortSwapAB
OBJECT-TYPE
Specifies whether pairA pairB cables are swapped
1.3.6.1.4.1.1916.1.24.3.1.4INTEGER {swap(1), noswap(2), unknown(3)}read-onlycurrent
extremeDiagPortSwapCD
OBJECT-TYPE
Specifies whether pairC and pairD cables are swapped
1.3.6.1.4.1.1916.1.24.3.1.5INTEGER {swap(1), noswap(2), unknown(3)}read-onlycurrent
extremeDiagPortPairAPol
OBJECT-TYPE
Specifies the polarity of pairA cables
1.3.6.1.4.1.1916.1.24.3.1.6INTEGER {positive(1), negative(2), unknown(3)}read-onlycurrent
extremeDiagPortPairAFlen
OBJECT-TYPE
Specifies the distance of Fault in the pairA cables
1.3.6.1.4.1.1916.1.24.3.1.7INTEGERread-onlycurrent
extremeDiagPortPairALen
OBJECT-TYPE
Specifies the length of the pairA cables
1.3.6.1.4.1.1916.1.24.3.1.8INTEGERread-onlycurrent
extremeDiagPortPairASkew
OBJECT-TYPE
Skew of pairA cables with respect to the fastest pair
1.3.6.1.4.1.1916.1.24.3.1.9INTEGERread-onlycurrent
extremeDiagPortPairAStatus
OBJECT-TYPE
Indicates whether pairA cables are properly terminated, short or open
1.3.6.1.4.1.1916.1.24.3.1.10INTEGER {open(1), short(2), terminated(3), imperror(4), unknown(5)}read-onlycurrent
extremeDiagPortPairBPol
OBJECT-TYPE
Specifies the polarity of pairB cables
1.3.6.1.4.1.1916.1.24.3.1.11INTEGER {positive(1), negative(2), unknown(3)}read-onlycurrent
extremeDiagPortPairBFlen
OBJECT-TYPE
Specifies the distance of Fault in the pairB cables
1.3.6.1.4.1.1916.1.24.3.1.12INTEGERread-onlycurrent
extremeDiagPortPairBLen
OBJECT-TYPE
Specifies the length of the pairB cables
1.3.6.1.4.1.1916.1.24.3.1.13INTEGERread-onlycurrent
extremeDiagPortPairBSkew
OBJECT-TYPE
Skew of pairB cables with respect to the fastest pair
1.3.6.1.4.1.1916.1.24.3.1.14INTEGERread-onlycurrent
extremeDiagPortPairBStatus
OBJECT-TYPE
Indicates whether pairB cables are properly terminated, short or open
1.3.6.1.4.1.1916.1.24.3.1.15INTEGER {open(1), short(2), terminated(3), imperror(4), unknown(5)}read-onlycurrent
extremeDiagPortPairCPol
OBJECT-TYPE
Specifies the polarity of pairC cables
1.3.6.1.4.1.1916.1.24.3.1.16INTEGER {positive(1), negative(2), unknown(3)}read-onlycurrent
extremeDiagPortPairCFlen
OBJECT-TYPE
Specifies the distance of Fault in the pairC cables
1.3.6.1.4.1.1916.1.24.3.1.17INTEGERread-onlycurrent
extremeDiagPortPairCLen
OBJECT-TYPE
Specifies the length of the pairC cables
1.3.6.1.4.1.1916.1.24.3.1.18INTEGERread-onlycurrent
extremeDiagPortPairCSkew
OBJECT-TYPE
Skew of pairC cables with respect to the fastest pair
1.3.6.1.4.1.1916.1.24.3.1.19INTEGERread-onlycurrent
extremeDiagPortPairCStatus
OBJECT-TYPE
Indicates whether pairC cables are properly terminated, short or open
1.3.6.1.4.1.1916.1.24.3.1.20INTEGER {open(1), short(2), terminated(3), imperror(4), unknown(5)}read-onlycurrent
extremeDiagPortPairDPol
OBJECT-TYPE
Specifies the polarity of pairD cables
1.3.6.1.4.1.1916.1.24.3.1.21INTEGER {positive(1), negative(2), unknown(3)}read-onlycurrent
extremeDiagPortPairDFlen
OBJECT-TYPE
Specifies the distance of Fault in the pairD cables
1.3.6.1.4.1.1916.1.24.3.1.22INTEGERread-onlycurrent
extremeDiagPortPairDLen
OBJECT-TYPE
Specifies the length of the pairD cables
1.3.6.1.4.1.1916.1.24.3.1.23INTEGERread-onlycurrent
extremeDiagPortPairDSkew
OBJECT-TYPE
Skew of pairD cables with respect to the fastest pair
1.3.6.1.4.1.1916.1.24.3.1.24INTEGERread-onlycurrent
extremeDiagPortPairDStatus
OBJECT-TYPE
Indicates whether pairD cables are properly terminated, short or open
1.3.6.1.4.1.1916.1.24.3.1.25INTEGER {open(1), short(2), terminated(3), imperror(4), unknown(5)}read-onlycurrent
extremeDiagPortDateTime
OBJECT-TYPE
Date and time at which the Diagnostic information was collected
1.3.6.1.4.1.1916.1.24.3.1.26DisplayString (SIZE(64))read-onlycurrent
extremeDiagPortStatsTable
OBJECT-TYPE
Table, which contains the diagnostic statistic information for the ports
1.3.6.1.4.1.1916.1.24.4not-accessiblecurrent
extremeDiagPortStatsEntry
OBJECT-TYPE
Each row represents port related diagnostics statistics information
1.3.6.1.4.1.1916.1.24.4.1not-accessiblecurrent
extremeDiagPortStatsPortIfIndex
OBJECT-TYPE
IfIndex of the Port for which the information in this row applies
1.3.6.1.4.1.1916.1.24.4.1.1INTEGERread-onlycurrent
extremeDiagPortStatsNumDiag
OBJECT-TYPE
Number of times Diagnostics information collected for this port
1.3.6.1.4.1.1916.1.24.4.1.2INTEGERread-onlycurrent
extremeDiagPortStatsNumSuccess
OBJECT-TYPE
Number of times Diagnostics for this port completed successfully without any errors
1.3.6.1.4.1.1916.1.24.4.1.3INTEGERread-onlycurrent
extremeDiagPortStatsNumFail
OBJECT-TYPE
Number of times Diagnostics for this port Failed due to errors in the cable pairs
1.3.6.1.4.1.1916.1.24.4.1.4INTEGERread-onlycurrent
extremeDiagPortStatsNumChange
OBJECT-TYPE
Number of times Diagnostics Changed for this port
1.3.6.1.4.1.1916.1.24.4.1.5INTEGERread-onlycurrent
extremeDiagPortStatsNumAbort
OBJECT-TYPE
Number of times Diagnostics was aborted by the user for this port
1.3.6.1.4.1.1916.1.24.4.1.6INTEGERread-onlycurrent
extremeCableTraps
OBJECT-IDENTITY
1.3.6.1.4.1.1916.4.13
extremeCableTrapsPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.1916.4.13.0

Notifications

NameOIDStatus
extremeTrapDiagPortDiagnostics
NOTIFICATION-TYPE
Indicates the status of Diagnostics for a port. The status indicates whether Diagnostics for a particular port failed
1.3.6.1.4.1.1916.4.13.0.1current