MIBs Depot

EXPRESSION-MIB

Registered at
1.3.6.1.4.1.9.10.22
Last updated
2005-11-24 00:00
Organization
IETF Distributed Management Working Group
Revisions
2005-11-24 00:00, 1998-02-25 17:00
Namespace
cisco
Source file
EXPRESSION-MIB
Digest
sha256:983cb6a14eba4bf7d3c8c4ea1bfcd7676d4dcdc2b7cd5cb7dcaf27746501dcf9

Description

The MIB module for defining expressions of MIB objects for network management purposes. This MIB is an early snapshot of work done by the IETF's Distributed Management working group. After this snapshot was taken, the MIB was modified, had new OIDs assigned, and then published as RFC 2982.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com

Imports

FromSymbols
CISCO-SMIciscoExperiment
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-MIBsysUpTime
SNMPv2-SMICounter32, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso, zeroDotZero
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-SMI
EXPRESSION-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
ExpressionIndex
TEXTUAL-CONVENTION
An integer shorthand identification for an expression. An ExpressionIndex corresponds one-to-one to an ExpressionName. Once assigned an ExpressionIndex may not be changed.
current
ExpressionIndexOrZero
TEXTUAL-CONVENTION
Either an ExpressionIndex or zero. The meaning of zero depends on the DESCRIPTION of the object.
current
ExpressionName
TEXTUAL-CONVENTION
This data type is a refinement of DisplayString to represent an identification for an expression. An ExpressionName corresponds one-to-one to an ExpressionIndex. This identification of an expression is subject to change only by administrative request.
current

Objects

NameOIDSyntaxAccessStatus
sysUpTimeInstance
OBJECT-IDENTITY
1.3.6.1.2.1.1.3.0
expressionMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.1
expResource
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.1.1
expResourceDeltaMinimum
OBJECT-TYPE
The minimum expExpressionDeltaInterval this system will accept. A system may use the larger values of this minimum to lessen the impact of constantly computing deltas. The value -1 indicates this system will not accept deltaValue as a value for expObjectSampleType. Unless explicitly resource limited, a system's value for this object should be 1. Changing this value will not invalidate an existing setting of expObjectSampleType.
1.3.6.1.4.1.9.10.22.1.1.1Integer32 (-1 | 1..600)read-writecurrent
expResourceDeltaWildcardInstanceMaximum
OBJECT-TYPE
The maximum number of dynamic instance entries this system will support for wildcarded delta objects in expressions. These are the entries that maintain state, one for each instance of each deltaValue object for each value of an expression. A value of 0 indicates no preset limit, that is, the limit is dynamic based on system operation and resources. Unless explicitly resource limited, a system's value for this object should be 0. Changing this value will not eliminate or inhibit existing delta wildcard instance objects but will prevent the creation of more such objects.
1.3.6.1.4.1.9.10.22.1.1.2Unsigned32read-writecurrent
expResourceDeltaWildcardInstances
OBJECT-TYPE
The number of currently active instance entries as defined for expResourceDeltaWildcardInstanceMaximum.
1.3.6.1.4.1.9.10.22.1.1.3Gauge32read-onlycurrent
expResourceDeltaWildcardInstancesHigh
OBJECT-TYPE
The highest value of expResourceDeltaWildcardInstances that has occurred since initialization of the management system.
1.3.6.1.4.1.9.10.22.1.1.4Gauge32read-onlycurrent
expResourceDeltaWildcardInstanceResourceLacks
OBJECT-TYPE
The number of times this system could not evaluate an expression because that would have created a value instance in excess of expResourceDeltaWildcardInstanceMaximum.
1.3.6.1.4.1.9.10.22.1.1.5Counter32read-onlycurrent
expNames
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.1.2
expNameLastChange
OBJECT-TYPE
The value of sysUpTime the last time an expression was created or deleted or had its name changed using expExpressionName.
1.3.6.1.4.1.9.10.22.1.2.1TimeStampread-onlycurrent
expNameHighestIndex
OBJECT-TYPE
The highest value of ExpressionIndex ever assigned on this system. Preferrably this value is preserved across system reboots. A managed system that is unable to store expressions across reboots need not preserve this value across reboots. If all expression-creating applications cooperate, they may use this to avoid reusing an ExpressionIndex. To do so, attempt creation of a new entry with this value + 1 as the value of expExpressionIndex. Although reusing ExpressionIndexes could lead to an application receiving a misunderstood value, it is a matter of local management policy whether to reuse them.
1.3.6.1.4.1.9.10.22.1.2.2ExpressionIndexOrZeroread-onlycurrent
expNameTable
OBJECT-TYPE
A table of expression names, for creating and deleting expressions.
1.3.6.1.4.1.9.10.22.1.2.3not-accessiblecurrent
expNameEntry
OBJECT-TYPE
Information about a single expression. New expressions can be created using expNameStatus. To create an expression first create the named entry in this table. Then use expExpressionIndex to populate expExpressionTable and expObjectTable. For expression evaluation to succeed all related entries in expNameTable, expExpressionTable, and expObjectTable must be 'active'. If these conditions are not met the corresponding values in expValue simply are not instantiated. Deleting an entry deletes all related entries in expExpressionTable and expObjectTable. Because of the relationships among the multiple tables for an expression (expNameTable, expExpressionTable, expObjectTable, and expValueTable) and the SNMP rules for independence in setting object values, it is necessary to do final error checking when an expression is evaluated, that is, when one of its instances in expValueTable is read. Earlier checking need not be done and an implementation may not impose any ordering on the creation of objects related to an expression other than to require values for expName and expExpressionIndex before any other related objects can be created. To maintain security of MIB information, when creating a new row in this table, the managed system must record the security credentials of the requester. If the subsequent expression includes objects with expObjectSampleType 'deltaValue' the evaluation of that expression takes place under the security credentials of the creator of its expNameEntry.
1.3.6.1.4.1.9.10.22.1.2.3.1not-accessiblecurrent
expName
OBJECT-TYPE
The name of the expression. Choosing names with useful lexical ordering supports using GetNext or GetBulk to retrieve a useful subset of the table.
1.3.6.1.4.1.9.10.22.1.2.3.1.1ExpressionNamenot-accessiblecurrent
expExpressionIndex
OBJECT-TYPE
The numeric identification of the expression. Applications may select this number in ascending numerical order by using expNameHighestIndex as a hint or may use any other acceptable, unused number. Once set this value may not be set to a different value.
1.3.6.1.4.1.9.10.22.1.2.3.1.2ExpressionIndexread-createcurrent
expNameStatus
OBJECT-TYPE
The control that allows creation/deletion of entries.
1.3.6.1.4.1.9.10.22.1.2.3.1.3RowStatusread-createcurrent
expDefine
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.1.3
expExpressionTable
OBJECT-TYPE
A table of expression definitions.
1.3.6.1.4.1.9.10.22.1.3.1not-accessiblecurrent
expExpressionEntry
OBJECT-TYPE
Information about a single expression. An entry appears in this table when an entry is created in expNameTable. Deleting that expNameTable entry automatically deletes this entry and its associated expObjectTable entries. Values of read-write objects in this table may be changed at any time.
1.3.6.1.4.1.9.10.22.1.3.1.1not-accessiblecurrent
expExpressionName
OBJECT-TYPE
The unique name of the expression, the same as expName. Use this object to change the expression's name without changing its expExpressionIndex.
1.3.6.1.4.1.9.10.22.1.3.1.1.1ExpressionNameread-writecurrent
expExpression
OBJECT-TYPE
The expression to be evaluated. This object is the same as a DisplayString (RFC 1903) except for its maximum length. Except for the variable names the expression is in ANSI C syntax. Only the subset of ANSI C operators and functions listed here is allowed. Variables are expressed as a dollar sign ('$') and an integer that corresponds to an expObjectIndex. An example of a valid expression is: ($1-$5)*100 Expressions may not be recursive, that is although an expression may use the results of another expression, it may not contain any variable that is directly or indirectly a result of its own evaluation. The only allowed operators are: ( ) - (unary) + - * / % & | ^ << >> ~ ! && || == != > >= < <= Note the parentheses are included for parenthesizing the expression, not for casting data types. The only constant types defined are: int (32-bit signed) long (64-bit signed) unsigned int unsigned long hexadecimal character string oid The default type for a positive integer is int unless it is too large in which case it is long. All but oid are as defined for ANSI C. Note that a hexadecimal constant may end up as a scalar or an array of 8-bit integers. A string constant is enclosed in double quotes and may contain back-slashed individual characters as in ANSI C. An oid constant comprises 32-bit, unsigned integers and at least one period, for example: 0. .0 1.3.6.1 Integer-typed objects are treated as 32- or 64-bit, signed or unsigned integers, as appropriate. The results of mixing them are as for ANSI C, including the type of the result. Note that a 32-bit value is thus promoted to 64 bits only in an operation with a 64-bit value. There is no provision for larger values to handle overflow. Relative to SNMP data types, a resulting value becomes unsigned when calculating it uses any unsigned value, including a counter. To force the final value to be of data type counter the expression must explicitly use the counter32() or counter64() function (defined below). OCTET STRINGS and OBJECT IDENTIFIERs are treated as 1-based arrays of unsigned 8-bit integers and unsigned 32-bit integers, respectively. IpAddresses are treated as 32-bit, unsigned integers in network byte order, that is, the hex version of 255.0.0.0 is 0xff000000. Conditional expressions result in a 32-bit, unsigned integer of value 0 for false or 1 for true. When an arbitrary value is used as a boolean 0 is false and non-zero is true. Rules for the resulting data type from an operation, based on the operator: For << and >> the result is the same as the left hand operand. For &&, ||, ==, !=, <, <=, >, and >= the result is always Unsigned32. For unary - the result is always Integer32. For +, -, *, /, %, &, |, and ^ the result is promoted according to the following rules, in order from most to least preferred: If left hand and right hand operands are the same type, use that. If either side is Counter64, use that. If either side is IpAddress, use that. If either side is TimeTicks, use that. If either side is Counter32, use that. Otherwise use Unsigned32. The following rules say what operators apply with what data types. Any combination not explicitly defined does not work. For all operators any of the following can be the left hand or right hand operand: Integer32, Counter32, Unsigned32, Counter64. The operators +, -, *, /, %, <, <=, >, and >= also work with TimeTicks. The operators &, |, and ^ also work with IpAddress. The operators << and >> also work with IpAddress but only as the left hand operand. The + operator performs a concatenation of two OCTET STRINGs or two OBJECT IDENTIFIERs. The operators &, | perform bitwise operations on OCTET STRINGs. If the OCTET STRING happens to be a DisplayString the results may be meaningless, but the agent system does not check this as some such systems do not have this information. The operators << and >> perform bitwise operations on OCTET STRINGs appearing as the left hand operand. The only functions defined are: counter32 counter64 arraySection stringBegins stringEnds stringContains oidBegins oidEnds oidContains sum exists The following function definitions indicate their by naming the data type of the parameter in the parameter's position in the parameter list. The parameter must be of the type indicated and generally may be a constant, a MIB object, a function, or an expression. counter32(integer) - wrapped around an integer value counter32 forces Counter32 as a data type. counter64(integer) - similar to counter32 except that the resulting data type is 'counter64'. arraySection(array, integer, integer) - selects a piece of an array (i.e. part of an OCTET STRING or OBJECT IDENTIFIER). The integer arguments are in the range 0 to 4,294,967,295. The first is an initial array index (1-based) and the second is an ending array index. A value of 0 indicates first or last element, respectively. If the first element is larger than the array length the result is 0 length. If the second integer is less than or equal to the first, the result is 0 length. If the second is larger than the array length it indicates last element. stringBegins/Ends/Contains(octetString, octetString) - looks for the second string (which can be a string constant) in the first and returns the 1-based index where the match began. A return value of 0 indicates no match (i.e. boolean false). oidBegins/Ends/Contains(oid, oid) - looks for the second OID (which can be an OID constant) in the first and returns the the 1-based index where the match began. A return value of 0 indicates no match (i.e. boolean false). sum(integerObject*) - sums all availiable values of the wildcarded integer object, resulting in an integer scalar. Must be used with caution as it wraps on overflow with no notification. exists(anyTypeObject) - verifies the object instance exists. A return value of 0 indicates NoSuchInstance (i.e. boolean false).
1.3.6.1.4.1.9.10.22.1.3.1.1.2OCTET STRING (SIZE(1..1024))read-writecurrent
expExpressionValueType
OBJECT-TYPE
The type of the expression value. One and only one of the value objects in expValueTable will be instantiated to match this type. If the result of the expression can not be made into this type, an invalidOperandType error will occur.
1.3.6.1.4.1.9.10.22.1.3.1.1.3INTEGER {counter32(1), unsignedOrGauge32(2), timeTicks(3), integer32(4), ipAddress(5), octetString(6), objectId(7), counter64(8)}read-writecurrent
expExpressionComment
OBJECT-TYPE
A comment to explain the use or meaning of the expression.
1.3.6.1.4.1.9.10.22.1.3.1.1.4DisplayStringread-writecurrent
expExpressionDeltaInterval
OBJECT-TYPE
Sampling interval for objects in this expression with expObjectSampleType 'deltaValue'. This object is not instantiated if not applicable. A value of 0 indicates no automated sampling. In this case the delta is the difference from the last time the expression was evaluated. Note that this is subject to unpredictable delta times in the face of retries or multiple managers. A value greater than zero is the number of seconds between automated samples. Until the delta interval has expired once the delta for the object is effectively not instantiated and evaluating the expression has results as if the object itself were not instantiated. Note that delta values potentially consume large amounts of system CPU and memory. Delta state and processing must continue constantly even if the expression is not being used. That is, the expression is being evaluated every delta interval, even if no application is reading those values. For wildcarded objects this can be substantial overhead. Note that delta intervals, external expression value sampling intervals and delta intervals for expressions within other expressions can have unusual interactions as they are impossible to synchronize accurately. In general one interval embedded below another must be enough shorter that the higher sample sees relatively smooth, predictable behavior.
1.3.6.1.4.1.9.10.22.1.3.1.1.5Integer32 (0..86400)read-writecurrent
expExpressionPrefix
OBJECT-TYPE
An object prefix to assist an application in determining the instance indexing to use in expValueTable, relieving the application of the need to scan the expObjectTable to determine such a prefix. See expObjectTable for information on wildcarded objects. If the expValueInstance portion of the value OID may be treated as a scalar (that is, normally, 0) the value of expExpressionPrefix is zero length, that is, no OID at all. Otherwise expExpressionPrefix is the value of any wildcarded instance of expObjectID for the expression. This is sufficient as the remainder, that is, the instance fragment relevant to instancing the values must be the same for all wildcarded objects in the expression.
1.3.6.1.4.1.9.10.22.1.3.1.1.6OBJECT IDENTIFIERread-onlycurrent
expExpressionErrors
OBJECT-TYPE
The number of errors encountered while evaluating this expression. Note that an object in the expression not being accessible is not considered an error. It is a legitimate condition that causes the corresponding expression value not to be instantiated.
1.3.6.1.4.1.9.10.22.1.3.1.1.7Counter32read-onlycurrent
expExpressionErrorTime
OBJECT-TYPE
The value of sysUpTime the last time an error caused a failure to evaluate this expression. This object is not instantiated if there have been no errors.
1.3.6.1.4.1.9.10.22.1.3.1.1.8TimeStampread-onlycurrent
expExpressionErrorIndex
OBJECT-TYPE
The 1-based character index into expExpression for where the error occurred. The value zero indicates irrelevance. This object is not instantiated if there have been no errors.
1.3.6.1.4.1.9.10.22.1.3.1.1.9Integer32read-onlycurrent
expExpressionError
OBJECT-TYPE
The error that occurred. In the following explanations the expected timing of the error is in parentheses. 'S' means the error occurs on a Set request. 'E' means the error occurs on the attempt to evaluate the expression either due to Get from expValueTable or in ongoing delta processing. invalidSyntax the value sent for expExpression is not valid Expression MIB expression syntax (S) undefinedObjectIndex an object reference ($n) in expExpression does not have a matching instance in expObjectTable (E) unrecognizedOperator the value sent for expExpression held an unrecognized operator (S) unrecognizedFunction the value sent for expExpression held an unrecognized function name (S) invalidOperandType an operand in expExpression is not the right type for the associated operator or result (SE) unmatchedParenthesis the value sent for expExpression is not correctly parenthesized (S) tooManyWildcardValues evaluating the expression exceeded the limit set by expResourceDelta WildcardInstanceMaximum (E) recursion through some chain of embedded expressions the expression invokes itself (E) deltaTooShort the delta for the next evaluation passed before the system could evaluate the present sample (E) resourceUnavailable some resource, typically dynamic memory, was unavailable (SE) divideByZero an attempt to divide by zero occurred (E) For the errors that occur when the attempt is made to set expExpression Set request fails with the SNMP error code 'wrongValue'. Such failures refer to the most recent failure to Set expExpression, not to the present value of expExpression which must be either unset or syntactically correct. Errors that occur during evalutaion for a Get* operation return the SNMP error code 'genErr' except for 'tooManyWildcardValues' and 'resourceUnavailable' which return the SNMP error code 'resourceUnavailable'. This object is not instantiated if there have been no errors.
1.3.6.1.4.1.9.10.22.1.3.1.1.10INTEGER {invalidSyntax(1), undefinedObjectIndex(2), unrecognizedOperator(3), unrecognizedFunction(4), invalidOperandType(5), unmatchedParenthesis(6), tooManyWildcardValues(7), recursion(8), deltaTooShort(9), resourceUnavailable(10), divideByZero(11)}read-onlycurrent
expExpressionInstance
OBJECT-TYPE
The expValueInstance being evaluated when the error occurred. A zero-length indicates irrelevance. This object is not instantiated if there have been no errors.
1.3.6.1.4.1.9.10.22.1.3.1.1.11OBJECT IDENTIFIERread-onlycurrent
expExpressionOwner
OBJECT-TYPE
The entity that configured this entry and is therefore using the resources assigned to it.
1.3.6.1.4.1.9.10.22.1.3.1.1.12DisplayString (SIZE(0..255))read-writecurrent
expObjectTable
OBJECT-TYPE
A table of object definitions for each expExpression. Wildcarding instance IDs: It is legal to omit all or part of the instance portion for some or all of the objects in an expression. (See the DESCRIPTION of expObjectID for details. However, note that if more than one object in the same expression is wildcarded in this way, they all must be objects where that portion of the instance is the same. In other words, all objects may be in the same SEQUENCE or in different SEQUENCEs but with the same semantic index value (e.g., a value of ifIndex) for the wildcarded portion.
1.3.6.1.4.1.9.10.22.1.3.2not-accessiblecurrent
expObjectEntry
OBJECT-TYPE
Information about an object. An application uses expObjectStatus to create entries in this table while in the process of defining an expression. Values of read-create objects in this table may be changed at any time.
1.3.6.1.4.1.9.10.22.1.3.2.1not-accessiblecurrent
expObjectIndex
OBJECT-TYPE
Within an expression, a unique, numeric identification for an object. Prefixed with a dollar sign ('$') this is used to reference the object in the corresponding expExpression.
1.3.6.1.4.1.9.10.22.1.3.2.1.1Unsigned32 (1..4294967295)not-accessiblecurrent
expObjectID
OBJECT-TYPE
The OBJECT IDENTIFIER (OID) of this object. The OID may be fully qualified, meaning it includes a complete instance identifier part (e.g., ifInOctets.1 or sysUpTime.0), or it may not be fully qualified, meaning it may lack all or part of the instance identifier. If the expObjectID is not fully qualified, then expObjectWildcard must be set to true(1). The value of the expression will be multiple values, as if done for a GetNext sweep of the object. An object here may itself be the result of an expression but recursion is not allowed. NOTE: The simplest implementations of this MIB may not allow wildcards.
1.3.6.1.4.1.9.10.22.1.3.2.1.2OBJECT IDENTIFIERread-createcurrent
expObjectIDWildcard
OBJECT-TYPE
A true value indicates the expObjecID of this row is a wildcard object. False indicates that expObjectID is fully instanced. If all expObjectWildcard values for a given expression are FALSE, expExpressionPrefix will reflect a scalar object (ie will be 0.0). NOTE: The simplest implementations of this MIB may not allow wildcards.
1.3.6.1.4.1.9.10.22.1.3.2.1.3TruthValueread-createcurrent
expObjectSampleType
OBJECT-TYPE
The method of sampling the selected variable. An 'absoluteValue' is simply the present value of the object. A 'deltaValue' is the present value minus the previous value, which was sampled expExpressionDeltaInterval seconds ago. This is intended primarily for use with SNMP counters, which are meaningless as an 'absoluteValue', but may be used with any integer-based value. When an expression contains both delta and absolute values the absolute values are obtained at the end of the delta period.
1.3.6.1.4.1.9.10.22.1.3.2.1.4INTEGER {absoluteValue(1), deltaValue(2)}read-createcurrent
expObjectDeltaDiscontinuityID
OBJECT-TYPE
The OBJECT IDENTIFIER (OID) of a TimeTicks or TimeStamp object that indicates a discontinuity in the value at expObjectID. This object is not instantiated if expObject is not 'deltaValue'. The OID may be for a leaf object (e.g. sysUpTime.0) or may be wildcarded to match expObjectID. This object supports normal checking for a discontinuity in a counter. Note that if this object does not point to sysUpTime discontinuity checking must still check sysUpTime for an overall discontinuity. If the object identified is not accessible no discontinuity check will be made.
1.3.6.1.4.1.9.10.22.1.3.2.1.5OBJECT IDENTIFIERread-createcurrent
expObjectDiscontinuityIDWildcard
OBJECT-TYPE
A true value indicates the expObjectDeltaDiscontinuityID of this row is a wildcard object. False indicates that expObjectDeltaDiscontinuityID is fully instanced. This object is not instantiated if expObject is not 'deltaValue'. NOTE: The simplest implementations of this MIB may not allow wildcards.
1.3.6.1.4.1.9.10.22.1.3.2.1.6TruthValueread-createcurrent
expObjectDiscontinuityIDType
OBJECT-TYPE
The value 'timeTicks' indicates the expObjectDeltaDiscontinuityID of this row is of syntax TimeTicks. The value 'timeStamp' indicates that expObjectDeltaDiscontinuityID is of syntax TimeStamp. This object is not instantiated if expObject is not 'deltaValue'.
1.3.6.1.4.1.9.10.22.1.3.2.1.7INTEGER {timeTicks(1), timeStamp(2)}read-createcurrent
expObjectConditional
OBJECT-TYPE
The OBJECT IDENTIFIER (OID) of an object that overrides whether the instance of expObjectID is to be considered usable. If the value of the object at expObjectConditional is 0 or not instantiated, the object at expObjectID is treated as if it is not instantiated. In other words, expObjectConditional is a filter that controls whether or not to use the value at expObjectID. The OID may be for a leaf object (e.g. sysObjectID.0) or may be wildcarded to match expObjectID. If expObject is wildcarded and expObjectID in the same row is not, the wild portion of expObjectConditional must match the wildcarding of the rest of the expression. If no object in the expression is wildcarded but expObjectConditional is, use the lexically first instance (if any) of expObjectConditional. If the value of expObjectConditional is 0.0 operation is as if the value pointed to by expObjectConditional is a non-zero (true) value. Note that expObjectConditional can not trivially use an object of syntax TruthValue, since the underlying value is not 0 or 1.
1.3.6.1.4.1.9.10.22.1.3.2.1.8OBJECT IDENTIFIERread-createcurrent
expObjectConditionalWildcard
OBJECT-TYPE
A true value indicates the expObjectConditional of this row is a wildcard object. False indicates that expObjectConditional is fully instanced. NOTE: The simplest implementations of this MIB may not allow wildcards.
1.3.6.1.4.1.9.10.22.1.3.2.1.9TruthValueread-createcurrent
expObjectStatus
OBJECT-TYPE
The control that allows creation/deletion of entries. Objects in this table may be changed while expObjectStatus is in any state.
1.3.6.1.4.1.9.10.22.1.3.2.1.10RowStatusread-createcurrent
expValue
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.1.4
expValueTable
OBJECT-TYPE
A table of values from evaluated expressions.
1.3.6.1.4.1.9.10.22.1.4.1not-accessiblecurrent
expValueEntry
OBJECT-TYPE
A single value from an evaluated expression. For a given instance, only one 'Val' object in the conceptual row will be instantiated, that is, the one with the appropriate type for the value. For values that contain no objects of expObjectSampleType 'deltaValue', reading a value from the table causes the evaluation of the expression for that value. For those that contain a 'deltaValue' the value read is as of the last delta interval. If in the attempt to evaluate the expression one or more of the necessary objects is not available, the corresponding entry in this table is effectively not instantiated. To maintain security of MIB information, expression evaluation must take place using security credentials for the implied Gets of the objects in the expression. For expressions with no deltaValue those security credentials are the ones that came with the Get* for the value. For expressions with a deltaValue the ongoing expression evaluation is under the security credentials of the creator of the corresponding expNameEntry.
1.3.6.1.4.1.9.10.22.1.4.1.1not-accessiblecurrent
expValueInstance
OBJECT-TYPE
The final instance portion of a value's OID according to the wildcarding in instances of expObjectID for the expression. The prefix of this OID fragment is 0.0, leading to the following behavior. If there is no wildcarding, the value is 0.0.0. In other words, there is one value which standing alone would have been a scalar with a 0 at the end of its OID. If there is wildcarding, the value is 0.0 followed by a value that the wildcard can take, thus defining one value instance for each real, possible value of the wildcard. So, for example, if the wildcard worked out to be an ifIndex, there is an expValueInstance for each applicable ifIndex.
1.3.6.1.4.1.9.10.22.1.4.1.1.1OBJECT IDENTIFIERnot-accessiblecurrent
expValueCounter32Val
OBJECT-TYPE
The value when expExpressionValueType is 'counter32'.
1.3.6.1.4.1.9.10.22.1.4.1.1.2Counter32read-onlycurrent
expValueUnsigned32Val
OBJECT-TYPE
The value when expExpressionValueType is 'unsignedOrGauge32' or 'timeTicks'.
1.3.6.1.4.1.9.10.22.1.4.1.1.3Unsigned32read-onlycurrent
expValueInteger32Val
OBJECT-TYPE
The value when expExpressionValueType is 'integer32'.
1.3.6.1.4.1.9.10.22.1.4.1.1.4Integer32read-onlycurrent
expValueIpAddressVal
OBJECT-TYPE
The value when expExpressionValueType is 'ipAddress'.
1.3.6.1.4.1.9.10.22.1.4.1.1.5IpAddressread-onlycurrent
expValueOctetStringVal
OBJECT-TYPE
The value when expExpressionValueType is 'octetString'.
1.3.6.1.4.1.9.10.22.1.4.1.1.6OCTET STRING (SIZE(0..65535))read-onlycurrent
expValueOidVal
OBJECT-TYPE
The value when expExpressionValueType is 'objectId'.
1.3.6.1.4.1.9.10.22.1.4.1.1.7OBJECT IDENTIFIERread-onlycurrent
expValueCounter64Val
OBJECT-TYPE
The value when expExpressionValueType is 'counter64'.
1.3.6.1.4.1.9.10.22.1.4.1.1.8Counter64read-onlycurrent
expressionMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.3
expressionMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.3.1
expressionMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.22.3.2

Conformance

NameOIDStatus
expressionMIBCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement the Expression MIB.
1.3.6.1.4.1.9.10.22.3.1.1current
expressionResourceGroup
OBJECT-GROUP
Expression definition resource management.
1.3.6.1.4.1.9.10.22.3.2.1current
expressionDefinitionGroup
OBJECT-GROUP
Expression definition resource management.
1.3.6.1.4.1.9.10.22.3.2.2current
expressionValueGroup
OBJECT-GROUP
Expression definition resource management.
1.3.6.1.4.1.9.10.22.3.2.3current