MIBs Depot

ETHER-WIS

Registered at
1.3.6.1.2.1.10.134
Last updated
2003-09-19 00:00
Organization
IETF Ethernet Interfaces and Hub MIB Working Group
Revisions
2003-09-19 00:00
Namespace
standard
Source file
ETHER-WIS
Digest
sha256:1b5b2ea9ac77d50d36d53a9d60d5319106683a730229ed99ba292c70c93c14c9

Description

The objects in this MIB module are used in conjunction with objects in the SONET-MIB and the MAU-MIB to manage the Ethernet WAN Interface Sublayer (WIS). The following reference is used throughout this MIB module: [IEEE 802.3 Std] refers to: IEEE Std 802.3, 2000 Edition: 'IEEE Standard for Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications', as amended by IEEE Std 802.3ae-2002, 'IEEE Standard for Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications - Media Access Control (MAC) Parameters, Physical Layer and Management Parameters for 10 Gb/s Operation', 30 August 2002. Of particular interest are Clause 50, 'WAN Interface Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s, 100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link Aggregation Management', and Clause 45, 'Management Data Input/Output (MDIO) Interface'. Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC 3637; see the RFC itself for full legal notices.

Contact

WG charter: http://www.ietf.org/html.charters/hubmib-charter.html Mailing Lists: General Discussion: hubmib@ietf.org To Subscribe: hubmib-request@ietf.org In Body: subscribe your_email_address Chair: Dan Romascanu Postal: Avaya Inc. Atidim Technology Park, Bldg. 3 Tel Aviv 61131 Israel Tel: +972 3 645 8414 E-mail: dromasca@avaya.com Editor: C. M. Heard Postal: 600 Rainbow Dr. #141 Mountain View, CA 94041-2542 USA Tel: +1 650-964-8391 E-mail: heard@pobox.com

Imports

FromSymbols
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIGauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
SONET-MIBsonetFarEndLineStuff2, sonetFarEndPathStuff2, sonetLineStuff2, sonetMediumCircuitIdentifier, sonetMediumLineCoding, sonetMediumLineType, sonetMediumLoopbackConfig, sonetMediumStuff2, sonetMediumType, sonetPathCurrentWidth, sonetPathStuff2, sonetSESthresholdSet, sonetSectionStuff2

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ETHER-WIS
IANAifType-MIB
IF-MIB
PerfHist-TC-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
SONET-MIB

Objects

NameOIDSyntaxAccessStatus
etherWisObjects
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.1
etherWisDevice
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.1.1
etherWisDeviceTable
OBJECT-TYPE
The table for Ethernet WIS devices
1.3.6.1.2.1.10.134.1.1.1not-accessiblecurrent
etherWisDeviceEntry
OBJECT-TYPE
An entry in the Ethernet WIS device table. For each instance of this object there MUST be a corresponding instance of sonetMediumEntry.
1.3.6.1.2.1.10.134.1.1.1.1not-accessiblecurrent
etherWisDeviceTxTestPatternMode
OBJECT-TYPE
This variable controls the transmit test pattern mode. The value none(1) puts the the WIS transmit path into the normal operating mode. The value squareWave(2) puts the WIS transmit path into the square wave test pattern mode described in [IEEE 802.3 Std.] subclause 50.3.8.1. The value prbs31(3) puts the WIS transmit path into the PRBS31 test pattern mode described in [IEEE 802.3 Std.] subclause 50.3.8.2. The value mixedFrequency(4) puts the WIS transmit path into the mixed frequency test pattern mode described in [IEEE 802.3 Std.] subclause 50.3.8.3. Any attempt to set this object to a value other than none(1) when the corresponding instance of ifAdminStatus has the value up(1) MUST be rejected with the error inconsistentValue, and any attempt to set the corresponding instance of ifAdminStatus to the value up(1) when an instance of this object has a value other than none(1) MUST be rejected with the error inconsistentValue.
1.3.6.1.2.1.10.134.1.1.1.1.1INTEGER {none(1), squareWave(2), prbs31(3), mixedFrequency(4)}read-writecurrent
etherWisDeviceRxTestPatternMode
OBJECT-TYPE
This variable controls the receive test pattern mode. The value none(1) puts the the WIS receive path into the normal operating mode. The value prbs31(3) puts the WIS receive path into the PRBS31 test pattern mode described in [IEEE 802.3 Std.] subclause 50.3.8.2. The value mixedFrequency(4) puts the WIS receive path into the mixed frequency test pattern mode described in [IEEE 802.3 Std.] subclause 50.3.8.3. Any attempt to set this object to a value other than none(1) when the corresponding instance of ifAdminStatus has the value up(1) MUST be rejected with the error inconsistentValue, and any attempt to set the corresponding instance of ifAdminStatus to the value up(1) when an instance of this object has a value other than none(1) MUST be rejected with the error inconsistentValue.
1.3.6.1.2.1.10.134.1.1.1.1.2INTEGER {none(1), prbs31(3), mixedFrequency(4)}read-writecurrent
etherWisDeviceRxTestPatternErrors
OBJECT-TYPE
This object counts the number of errors detected when the WIS receive path is operating in the PRBS31 test pattern mode. It is reset to zero when the WIS receive path initially enters that mode, and it increments each time the PRBS pattern checker detects an error as described in [IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is 65535, in which case it remains unchanged. This object is writeable so that it may be reset upon explicit request of a command generator application while the WIS receive path continues to operate in PRBS31 test pattern mode.
1.3.6.1.2.1.10.134.1.1.1.1.3Gauge32 (0..65535)read-writecurrent
etherWisSection
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.1.2
etherWisSectionCurrentTable
OBJECT-TYPE
The table for the current state of Ethernet WIS sections.
1.3.6.1.2.1.10.134.1.2.1not-accessiblecurrent
etherWisSectionCurrentEntry
OBJECT-TYPE
An entry in the etherWisSectionCurrentTable. For each instance of this object there MUST be a corresponding instance of sonetSectionCurrentEntry.
1.3.6.1.2.1.10.134.1.2.1.1not-accessiblecurrent
etherWisSectionCurrentJ0Transmitted
OBJECT-TYPE
This is the 16-octet section trace message that is transmitted in the J0 byte. The value SHOULD be '89'h followed by fifteen octets of '00'h (or some cyclic shift thereof) when the section trace function is not used, and the implementation SHOULD use that value (or a cyclic shift thereof) as a default if no other value has been set.
1.3.6.1.2.1.10.134.1.2.1.1.1OCTET STRING (SIZE(16))read-writecurrent
etherWisSectionCurrentJ0Received
OBJECT-TYPE
This is the 16-octet section trace message that was most recently received in the J0 byte.
1.3.6.1.2.1.10.134.1.2.1.1.2OCTET STRING (SIZE(16))read-onlycurrent
etherWisObjectsPath
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.2
etherWisPath
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.2.1
etherWisPathCurrentTable
OBJECT-TYPE
The table for the current state of Ethernet WIS paths.
1.3.6.1.2.1.10.134.2.1.1not-accessiblecurrent
etherWisPathCurrentEntry
OBJECT-TYPE
An entry in the etherWisPathCurrentTable. For each instance of this object there MUST be a corresponding instance of sonetPathCurrentEntry.
1.3.6.1.2.1.10.134.2.1.1.1not-accessiblecurrent
etherWisPathCurrentStatus
OBJECT-TYPE
This variable indicates the current status of the path payload with a bit map that can indicate multiple defects at once. The bit positions are assigned as follows: etherWisPathLOP(0) This bit is set to indicate that an LOP-P (Loss of Pointer - Path) defect is being experienced. Note: when this bit is set, sonetPathSTSLOP MUST be set in the corresponding instance of sonetPathCurrentStatus. etherWisPathAIS(1) This bit is set to indicate that an AIS-P (Alarm Indication Signal - Path) defect is being experienced. Note: when this bit is set, sonetPathSTSAIS MUST be set in the corresponding instance of sonetPathCurrentStatus. etherWisPathPLM(1) This bit is set to indicate that a PLM-P (Payload Label Mismatch - Path) defect is being experienced. Note: when this bit is set, sonetPathSignalLabelMismatch MUST be set in the corresponding instance of sonetPathCurrentStatus. etherWisPathLCD(3) This bit is set to indicate that an LCD-P (Loss of Codegroup Delination - Path) defect is being experienced. Since this defect is detected by the PCS and not by the path layer itself, there is no corresponding bit in sonetPathCurrentStatus.
1.3.6.1.2.1.10.134.2.1.1.1.1Bits {etherWisPathLOP(0), etherWisPathAIS(1), etherWisPathPLM(2), etherWisPathLCD(3)}read-onlycurrent
etherWisPathCurrentJ1Transmitted
OBJECT-TYPE
This is the 16-octet path trace message that is transmitted in the J1 byte. The value SHOULD be '89'h followed by fifteen octets of '00'h (or some cyclic shift thereof) when the path trace function is not used, and the implementation SHOULD use that value (or a cyclic shift thereof) as a default if no other value has been set.
1.3.6.1.2.1.10.134.2.1.1.1.2OCTET STRING (SIZE(16))read-writecurrent
etherWisPathCurrentJ1Received
OBJECT-TYPE
This is the 16-octet path trace message that was most recently received in the J1 byte.
1.3.6.1.2.1.10.134.2.1.1.1.3OCTET STRING (SIZE(16))read-onlycurrent
etherWisFarEndPath
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.2.2
etherWisFarEndPathCurrentTable
OBJECT-TYPE
The table for the current far-end state of Ethernet WIS paths.
1.3.6.1.2.1.10.134.2.2.1not-accessiblecurrent
etherWisFarEndPathCurrentEntry
OBJECT-TYPE
An entry in the etherWisFarEndPathCurrentTable. For each instance of this object there MUST be a corresponding instance of sonetFarEndPathCurrentEntry.
1.3.6.1.2.1.10.134.2.2.1.1not-accessiblecurrent
etherWisFarEndPathCurrentStatus
OBJECT-TYPE
This variable indicates the current status at the far end of the path using a bit map that can indicate multiple defects at once. The bit positions are assigned as follows: etherWisFarEndPayloadDefect(0) A far end payload defect (i.e., far end PLM-P or LCD-P) is currently being signaled in G1 bits 5-7. etherWisFarEndServerDefect(1) A far end server defect (i.e., far end LOP-P or AIS-P) is currently being signaled in G1 bits 5-7. Note: when this bit is set, sonetPathSTSRDI MUST be set in the corresponding instance of sonetPathCurrentStatus.
1.3.6.1.2.1.10.134.2.2.1.1.1Bits {etherWisFarEndPayloadDefect(0), etherWisFarEndServerDefect(1)}read-onlycurrent
etherWisConformance
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.3
etherWisGroups
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.3.1
etherWisCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.10.134.3.2

Conformance

NameOIDStatus
etherWisDeviceGroupBasic
OBJECT-GROUP
A collection of objects that support test features required of all WIS devices.
1.3.6.1.2.1.10.134.3.1.1current
etherWisDeviceGroupExtra
OBJECT-GROUP
A collection of objects that support optional WIS device test features.
1.3.6.1.2.1.10.134.3.1.2current
etherWisSectionGroup
OBJECT-GROUP
A collection of objects that provide required information about a WIS section.
1.3.6.1.2.1.10.134.3.1.3current
etherWisPathGroup
OBJECT-GROUP
A collection of objects that provide required information about a WIS path.
1.3.6.1.2.1.10.134.3.1.4current
etherWisFarEndPathGroup
OBJECT-GROUP
A collection of objects that provide required information about the far end of a WIS path.
1.3.6.1.2.1.10.134.3.1.5current
etherWisCompliance
MODULE-COMPLIANCE
The compliance statement for interfaces that include the Ethernet WIS. Compliance with the following external compliance statements is prerequisite: MIB Module Compliance Statement ---------- -------------------- IF-MIB ifCompliance3 IF-INVERTED-STACK-MIB ifInvCompliance EtherLike-MIB dot3Compliance2 MAU-MIB mauModIfCompl3
1.3.6.1.2.1.10.134.3.2.1current