ES-RACKTIVITY-MIB
- Registered at
- 1.3.6.1.4.1.34097
- Last updated
- 2014-04-23 03:33
- Organization
- Racktivity
- Revisions
- 2014-04-23 03:33
- Namespace
- racktivity
- Source file
ES-RACKTIVITY-MIB- Digest
sha256:fd64aab861d0588186bca5b550581c02a67a1e2b67d2c2b917029f96185798d3
Description
The MIB module for the Racktivity Devices
Contact
http://www.racktivity.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, MacAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ES-RACKTIVITY-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| CURPORTSTATE TEXTUAL-CONVENTION enumeration of all port states possible | current | |||
| EVENTFLAGS TEXTUAL-CONVENTION enumeration of all eventflags possible | current | |||
| Shundredth TEXTUAL-CONVENTION 0.01 | current | |||
| Stenth TEXTUAL-CONVENTION 0.1 | current | |||
| Sthousandth TEXTUAL-CONVENTION 0.001 | current | |||
| Uhundredth TEXTUAL-CONVENTION 0.01 | current | |||
| Utenth TEXTUAL-CONVENTION 0.1 | current | |||
| Uthousandth TEXTUAL-CONVENTION 0.001 | current | |||
| Version TEXTUAL-CONVENTION Displays a version number | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| racktivity OBJECT-IDENTITY | 1.3.6.1.4.1.34097 | |||
| racktivityNotif OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.0 | |||
| esRacktivityConformance OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.2 | |||
| esRacktivityMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.2.1 | |||
| esRacktivityMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.2.2 | |||
| esnModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.65 | |||
| eESNTable OBJECT-TYPE Temperature Humidity Presure Airflow Waterleak | 1.3.6.1.4.1.34097.9.65.1 | not-accessible | current | |
| eESNEntry OBJECT-TYPE Temperature Humidity Presure Airflow Waterleak | 1.3.6.1.4.1.34097.9.65.1.1 | not-accessible | current | |
| aGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.65.1.1.1 | Unsigned32 | read-only | current |
| aSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.65.1.1.2 | Unsigned32 | read-only | current |
| aCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.65.1.1.3 | TimeTicks | read-write | current |
| aVoltage OBJECT-TYPE Gets the voltage of a power module. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.65.1.1.4 | Uhundredth | read-only | current |
| aStatePortCur OBJECT-TYPE Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead. | 1.3.6.1.4.1.34097.9.65.1.1.8 | CURPORTSTATE | read-only | current |
| aTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.65.1.1.11 | Utenth | read-only | current |
| aHumidity OBJECT-TYPE Gets the relative humidity. (unit: 0.1RH) | 1.3.6.1.4.1.34097.9.65.1.1.12 | Utenth | read-only | current |
| aAirflow OBJECT-TYPE Gets the current airflow level. (unit: 0.1m/s) | 1.3.6.1.4.1.34097.9.65.1.1.23 | Utenth | read-only | current |
| aDewPoint OBJECT-TYPE Gets the current dewpoint. Taking the current humidity into consideration, condensation will occur if the temperature drops below this level. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.65.1.1.25 | Utenth (0..65535) | read-only | current |
| aPressure OBJECT-TYPE Gets the atmospheric pressure. (unit: 0.1hPa) | 1.3.6.1.4.1.34097.9.65.1.1.26 | Utenth | read-only | current |
| aAnalogueInput OBJECT-TYPE Gets the value of an analog input (voltage). (unit: mV) | 1.3.6.1.4.1.34097.9.65.1.1.27 | Unsigned32 | read-only | current |
| aWaterleak OBJECT-TYPE Gets the current state of the water leak sensor. | 1.3.6.1.4.1.34097.9.65.1.1.28 | Unsigned32 | read-only | current |
| aMotionDetected OBJECT-TYPE Gets or resets whether motion has been detected. | 1.3.6.1.4.1.34097.9.65.1.1.29 | Unsigned32 | read-only | current |
| aIOPort OBJECT-TYPE Gets the state of a digital input. | 1.3.6.1.4.1.34097.9.65.1.1.30 | Unsigned32 (0..1) | read-only | current |
| aHighCurrent OBJECT-TYPE The current for high values (unit: 0.1A) | 1.3.6.1.4.1.34097.9.65.1.1.41 | Stenth (-32768..32767) | read-only | current |
| aHighPower OBJECT-TYPE The power for high values (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.65.1.1.43 | Shundredth (-32768..32767) | read-only | current |
| aModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.65.1.1.10001 | DisplayString | read-write | current |
| aFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.65.1.1.10002 | Version | read-only | current |
| aHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.65.1.1.10003 | Version | read-only | current |
| aFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.65.1.1.10004 | DisplayString | read-only | current |
| aHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.65.1.1.10005 | DisplayString | read-only | current |
| aDisplayTimeOn OBJECT-TYPE Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min) | 1.3.6.1.4.1.34097.9.65.1.1.10032 | Unsigned32 (0..255) | read-write | current |
| aMaxVoltageWarning OBJECT-TYPE Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.65.1.1.10047 | Uhundredth (0..65535) | read-write | current |
| aMinVoltageWarning OBJECT-TYPE Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.65.1.1.10049 | Uhundredth (0..65535) | read-write | current |
| aMinTemperatureWarning OBJECT-TYPE Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.65.1.1.10052 | Utenth (2232..4732) | read-write | current |
| aMaxTemperatureWarning OBJECT-TYPE Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.65.1.1.10053 | Utenth (2232..4732) | read-write | current |
| aMinHumidityWarning OBJECT-TYPE Gets, sets or defaults the minimum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH) | 1.3.6.1.4.1.34097.9.65.1.1.10054 | Utenth (0..1000) | read-write | current |
| aMaxHumidityWarning OBJECT-TYPE Gets, sets or defaults the maximum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH) | 1.3.6.1.4.1.34097.9.65.1.1.10055 | Utenth (0..1000) | read-write | current |
| aCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10078 | EVENTFLAGS | read-write | current |
| aPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the power warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10080 | EVENTFLAGS | read-write | current |
| aVoltageWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the voltage warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10086 | EVENTFLAGS | read-write | current |
| aTemperatureWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the temperature warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10087 | EVENTFLAGS | read-write | current |
| aHumidityWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the humidity warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10088 | EVENTFLAGS | read-write | current |
| aDewPointWarning OBJECT-TYPE Gets, sets or defaults the dewpoint warning level. If the temperature difference between the current temperature and the dewpoint temperature drops below this value, an event is generated. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.65.1.1.10092 | Utenth (0..65535) | read-write | current |
| aDewPointWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the dewpoint warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10093 | EVENTFLAGS | read-write | current |
| aDewPointViolationEvent OBJECT-TYPE Enables or disables the SNMP trap if the dewpoint temperature is reached. | 1.3.6.1.4.1.34097.9.65.1.1.10094 | EVENTFLAGS | read-write | current |
| aPressureWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the atmospheric pressure warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10095 | EVENTFLAGS | read-write | current |
| aMinPressureWarning OBJECT-TYPE Gets, sets or defaults the minimum atmospheric pressure warning level. (unit: 0.1hPa) | 1.3.6.1.4.1.34097.9.65.1.1.10096 | Utenth (0..65535) | read-write | current |
| aMaxPressureWarning OBJECT-TYPE Gets, sets or defaults the maximum atmospheric pressure warning level. (unit: 0.1hPa) | 1.3.6.1.4.1.34097.9.65.1.1.10097 | Utenth (0..65535) | read-write | current |
| aDisplayBrightness OBJECT-TYPE Gets, sets or defaults the display brightness (if supported). | 1.3.6.1.4.1.34097.9.65.1.1.10098 | Unsigned32 (0..255) | read-write | current |
| aMotionSensitivity OBJECT-TYPE Gets, sets or defaults the sensitivity of a motion sensor. | 1.3.6.1.4.1.34097.9.65.1.1.10107 | Unsigned32 (0..127) | read-write | current |
| aExternalSensorLabel OBJECT-TYPE Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors. | 1.3.6.1.4.1.34097.9.65.1.1.10109 | DisplayString | read-write | current |
| aRelayLabel OBJECT-TYPE Gets, sets or defaults an Energy Sensor relay label. | 1.3.6.1.4.1.34097.9.65.1.1.10110 | DisplayString | read-write | current |
| aMinAnalogueInputWarning OBJECT-TYPE Gets, sets or defaults the lower warning level for an analog input. A warning is generated if this level is exceeded. (unit: mV) | 1.3.6.1.4.1.34097.9.65.1.1.10111 | Unsigned32 (0..65535) | read-write | current |
| aMaxAnalogueInputWarning OBJECT-TYPE Gets, sets or defaults the upper warning level for an analog input. A warning is generated if this level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10112 | Unsigned32 (0..65535) | read-write | current |
| aWaterleakWarning OBJECT-TYPE Gets, sets or defaults the water leak detection state (0 = disabled, other values = enabled). | 1.3.6.1.4.1.34097.9.65.1.1.10113 | Unsigned32 (0..65535) | read-write | current |
| aMinAirflowWarning OBJECT-TYPE Gets, sets or defaults the minimum warning level for an airflow sensor. A warning is generated if this level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10114 | Unsigned32 (0..65535) | read-write | current |
| aMaxAirflowWarning OBJECT-TYPE Gets, sets or defaults the maximum warning level for an airflow sensor. A warning is generated if this level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10115 | Unsigned32 (0..65535) | read-write | current |
| aAnalogueInputWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the analog input warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10116 | EVENTFLAGS | read-write | current |
| aWaterleakWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if a water leak is detected. | 1.3.6.1.4.1.34097.9.65.1.1.10117 | EVENTFLAGS | read-write | current |
| aAirflowWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the airflow warning level is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10118 | EVENTFLAGS | read-write | current |
| aRelayAssertActionEvent OBJECT-TYPE Enables or disables the SNMP trap if an Energy Sensor relay is asserted. | 1.3.6.1.4.1.34097.9.65.1.1.10119 | EVENTFLAGS | read-write | current |
| aRelayDeassertActionEvent OBJECT-TYPE Enables or disables the SNMP trap if an Energy Sensor relay is deasserted. | 1.3.6.1.4.1.34097.9.65.1.1.10120 | EVENTFLAGS | read-write | current |
| aMotionWarning OBJECT-TYPE Gets, sets or defaults the motion warning threshold. | 1.3.6.1.4.1.34097.9.65.1.1.10141 | Unsigned32 (0..127) | read-write | current |
| aMotionWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the motion warning threshold is exceeded. | 1.3.6.1.4.1.34097.9.65.1.1.10149 | EVENTFLAGS | read-write | current |
| aDeviceID OBJECT-TYPE The ID of the device. | 1.3.6.1.4.1.34097.9.65.1.1.10150 | DisplayString | read-only | current |
| aDeviceVersion OBJECT-TYPE The version of the device. | 1.3.6.1.4.1.34097.9.65.1.1.10151 | Version | read-only | current |
| aSysName OBJECT-TYPE The full name of the device. | 1.3.6.1.4.1.34097.9.65.1.1.10152 | DisplayString | read-only | current |
| aMaxHighCurrentWarning OBJECT-TYPE Gets sets or defaults the maximum high current warning level. (unit: 0.1A) | 1.3.6.1.4.1.34097.9.65.1.1.10165 | Stenth (-32768..32767) | read-write | current |
| aMinHighCurrentWarning OBJECT-TYPE Gets sets or defaults the minimum high current warning level. (unit: 0.1A) | 1.3.6.1.4.1.34097.9.65.1.1.10176 | Stenth (-32768..32767) | read-write | current |
| aMinHighPowerWarning OBJECT-TYPE Gets sets or defaults the power min high current warning level. (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.65.1.1.10177 | Shundredth (-32768..32767) | read-write | current |
| aMaxHighPowerWarning OBJECT-TYPE Gets sets or defaults the power max high current warning level. (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.65.1.1.10178 | Shundredth (-32768..32767) | read-write | current |
| aIOPortWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the IO Port change state. | 1.3.6.1.4.1.34097.9.65.1.1.10192 | EVENTFLAGS | read-write | current |
| esnIndex OBJECT-TYPE Index for the selected ESN Module | 1.3.6.1.4.1.34097.9.65.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| esnModuleIndex OBJECT-TYPE Selected ESN Module | 1.3.6.1.4.1.34097.9.65.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| threephasepowerModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.66 | |||
| eThreePhasePowerTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.66.1 | not-accessible | current | |
| eThreePhasePowerEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.66.1.1 | not-accessible | current | |
| threephasepowerIndex OBJECT-TYPE Index for the selected ThreePhasePower Module | 1.3.6.1.4.1.34097.9.66.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| threephasepowerModuleIndex OBJECT-TYPE Selected ThreePhasePower Module | 1.3.6.1.4.1.34097.9.66.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| displaymoduleModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.68 | |||
| eDisplayModuleTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.68.1 | not-accessible | current | |
| eDisplayModuleEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.68.1.1 | not-accessible | current | |
| dGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.68.1.1.1 | Unsigned32 | read-only | current |
| dSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.68.1.1.2 | Unsigned32 | read-only | current |
| dCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.68.1.1.3 | TimeTicks | read-write | current |
| dTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.68.1.1.11 | Utenth | read-only | current |
| dTimeOnline OBJECT-TYPE Gets the amount of seconds since the last reset. (unit: s) | 1.3.6.1.4.1.34097.9.68.1.1.24 | Unsigned32 | read-only | current |
| dModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.68.1.1.10001 | DisplayString | read-write | current |
| dFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.68.1.1.10002 | Version | read-only | current |
| dHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.68.1.1.10003 | Version | read-only | current |
| dFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.68.1.1.10004 | DisplayString | read-only | current |
| dHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.68.1.1.10005 | DisplayString | read-only | current |
| dMinTemperatureWarning OBJECT-TYPE Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.68.1.1.10052 | Utenth (2232..4732) | read-write | current |
| dMaxTemperatureWarning OBJECT-TYPE Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.68.1.1.10053 | Utenth (2232..4732) | read-write | current |
| dDisplayAllDevices OBJECT-TYPE If a display need to show all devices or just a small list | 1.3.6.1.4.1.34097.9.68.1.1.10237 | Unsigned32 (0..1) | read-write | current |
| displaymoduleIndex OBJECT-TYPE Index for the selected DisplayModule Module | 1.3.6.1.4.1.34097.9.68.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| displaymoduleModuleIndex OBJECT-TYPE Selected DisplayModule Module | 1.3.6.1.4.1.34097.9.68.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| energymonitorModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.69 | |||
| eEnergyMonitorTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.69.1 | not-accessible | current | |
| eEnergyMonitorEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.69.1.1 | not-accessible | current | |
| eGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.69.1.1.1 | Unsigned32 | read-only | current |
| eSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.69.1.1.2 | Unsigned32 | read-only | current |
| eCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.69.1.1.3 | TimeTicks | read-write | current |
| eVoltage OBJECT-TYPE Gets the voltage of a power module. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.69.1.1.4 | Uhundredth | read-only | current |
| eFrequency OBJECT-TYPE Gets the frequency of the input voltage of a power module. (unit: 0.001Hz) | 1.3.6.1.4.1.34097.9.69.1.1.5 | Uthousandth | read-only | current |
| eCurrent OBJECT-TYPE Gets the current of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.69.1.1.6 | Uthousandth | read-only | current |
| ePower OBJECT-TYPE Gets the power of an outlet. (unit: W) | 1.3.6.1.4.1.34097.9.69.1.1.7 | Unsigned32 | read-only | current |
| eActiveEnergy OBJECT-TYPE Gets the energy used by an outlet. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.69.1.1.9 | Uthousandth | read-only | current |
| eApparentEnergy OBJECT-TYPE Gets the apparent energy used by an outlet. (unit: 0.001kVAh) | 1.3.6.1.4.1.34097.9.69.1.1.10 | Uthousandth | read-only | current |
| eTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.69.1.1.11 | Utenth | read-only | current |
| eApparentPower OBJECT-TYPE Gets the apparent power of an outlet. (unit: VA) | 1.3.6.1.4.1.34097.9.69.1.1.15 | Unsigned32 | read-only | current |
| ePowerFactor OBJECT-TYPE Gets the power factor of an outlet. (unit: %) | 1.3.6.1.4.1.34097.9.69.1.1.16 | Unsigned32 | read-only | current |
| eTotalCurrent OBJECT-TYPE Gets the total current of a power module. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.69.1.1.17 | Uthousandth | read-only | current |
| eTotalRealPower OBJECT-TYPE Gets the total power level of a power module. (unit: W) | 1.3.6.1.4.1.34097.9.69.1.1.18 | Unsigned32 | read-only | current |
| eTotalApparentPower OBJECT-TYPE Gets the total apparent power of a power module. (unit: VA) | 1.3.6.1.4.1.34097.9.69.1.1.19 | Unsigned32 | read-only | current |
| eTotalActiveEnergy OBJECT-TYPE Gets the total energy of a power module. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.69.1.1.20 | Uthousandth | read-only | current |
| eTotalApparentEnergy OBJECT-TYPE Gets the total apparent energy of a power module. (unit: 0.001kVAh) | 1.3.6.1.4.1.34097.9.69.1.1.21 | Uthousandth | read-only | current |
| eTotalPowerFactor OBJECT-TYPE Gets the total power factor of a power module. (unit: %) | 1.3.6.1.4.1.34097.9.69.1.1.22 | Unsigned32 | read-only | current |
| eTimeOnline OBJECT-TYPE Gets the amount of seconds since the last reset. (unit: s) | 1.3.6.1.4.1.34097.9.69.1.1.24 | Unsigned32 | read-only | current |
| eTotalHarmonicDistortion OBJECT-TYPE total harmonic distortion - outlet (unit: 0.1%) | 1.3.6.1.4.1.34097.9.69.1.1.50 | Utenth (0..1000) | read-only | current |
| eModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.69.1.1.10001 | DisplayString | read-write | current |
| eFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.69.1.1.10002 | Version | read-only | current |
| eHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.69.1.1.10003 | Version | read-only | current |
| eFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.69.1.1.10004 | DisplayString | read-only | current |
| eHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.69.1.1.10005 | DisplayString | read-only | current |
| eMaxCurrentWarning OBJECT-TYPE Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.69.1.1.10039 | Uthousandth (100..8000) | read-write | current |
| eMaxPowerWarning OBJECT-TYPE Gets, sets or defaults the maximum power warning level of an outlet. (unit: W) | 1.3.6.1.4.1.34097.9.69.1.1.10041 | Unsigned32 (20..2000) | read-write | current |
| eMaxTotalCurrentWarning OBJECT-TYPE Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.69.1.1.10043 | Uthousandth (100..16000) | read-write | current |
| eMaxTotalPowerWarning OBJECT-TYPE Gets, sets or defaults the maximum total power warning level. (unit: W) | 1.3.6.1.4.1.34097.9.69.1.1.10045 | Unsigned32 (20..4000) | read-write | current |
| eMaxVoltageWarning OBJECT-TYPE Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.69.1.1.10047 | Uhundredth (5000..30000) | read-write | current |
| eMinVoltageWarning OBJECT-TYPE Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.69.1.1.10049 | Uhundredth (5000..30000) | read-write | current |
| eMinTemperatureWarning OBJECT-TYPE Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.69.1.1.10052 | Utenth (2232..4732) | read-write | current |
| eMaxTemperatureWarning OBJECT-TYPE Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.69.1.1.10053 | Utenth (2232..4732) | read-write | current |
| eCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.69.1.1.10078 | EVENTFLAGS | read-write | current |
| ePowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the power warning level is exceeded. | 1.3.6.1.4.1.34097.9.69.1.1.10080 | EVENTFLAGS | read-write | current |
| eTotalCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the total outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.69.1.1.10082 | EVENTFLAGS | read-write | current |
| eTotalPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the total power warning level is exceeded. | 1.3.6.1.4.1.34097.9.69.1.1.10084 | EVENTFLAGS | read-write | current |
| eVoltageWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the voltage warning level is exceeded. | 1.3.6.1.4.1.34097.9.69.1.1.10086 | EVENTFLAGS | read-write | current |
| eTemperatureWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the temperature warning level is exceeded. | 1.3.6.1.4.1.34097.9.69.1.1.10087 | EVENTFLAGS | read-write | current |
| eMicroIntTimeThreshold OBJECT-TYPE The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms) | 1.3.6.1.4.1.34097.9.69.1.1.10135 | Utenth (10..65535) | read-write | current |
| eMicroIntEvent OBJECT-TYPE Enables or disables the SNMP trap if a microinterruption on the voltage is detected. | 1.3.6.1.4.1.34097.9.69.1.1.10136 | EVENTFLAGS | read-write | current |
| energymonitorIndex OBJECT-TYPE Index for the selected EnergyMonitor Module | 1.3.6.1.4.1.34097.9.69.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| energymonitorModuleIndex OBJECT-TYPE Selected EnergyMonitor Module | 1.3.6.1.4.1.34097.9.69.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| masterModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.77 | |||
| eMasterTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.77.1 | not-accessible | current | |
| eMasterEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.77.1.1 | not-accessible | current | |
| mGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.77.1.1.1 | Unsigned32 | read-only | current |
| mSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.77.1.1.2 | Unsigned32 | read-only | current |
| mCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.77.1.1.3 | TimeTicks | read-write | current |
| mVoltage OBJECT-TYPE Gets the voltage of a power module. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.77.1.1.4 | Uhundredth | read-only | current |
| mTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.77.1.1.11 | Utenth | read-only | current |
| mCurrentIP OBJECT-TYPE Gets the current IP address. To set the IP address, use IPADDR instead. | 1.3.6.1.4.1.34097.9.77.1.1.14 | IpAddress | read-only | current |
| mTotalCurrent OBJECT-TYPE Gets the total current of a power module. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.17 | Uthousandth | read-only | current |
| mTotalRealPower OBJECT-TYPE Gets the total power level of a power module. (unit: W) | 1.3.6.1.4.1.34097.9.77.1.1.18 | Unsigned32 | read-only | current |
| mTotalActiveEnergy OBJECT-TYPE Gets the total energy of a power module. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.77.1.1.20 | Uthousandth | read-only | current |
| mLineCurrent OBJECT-TYPE Gets the current line current. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.32 | Uthousandth (0..65535) | read-only | current |
| mFuseCurrent OBJECT-TYPE Gets the current through a fuse. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.33 | Uthousandth (0..65535) | read-only | current |
| mCurrentSubNetMask OBJECT-TYPE Gets the current subnet mask. To set the subnet mask use SNMSK instead. | 1.3.6.1.4.1.34097.9.77.1.1.34 | IpAddress | read-only | current |
| mCurrentDNSServer OBJECT-TYPE Gets the current DNS server. To set the DNS server use DNSSRV instead. | 1.3.6.1.4.1.34097.9.77.1.1.35 | IpAddress | read-only | current |
| mCurrentStdGateway OBJECT-TYPE Gets the current standard gateway. To set the standard gateway use STDGW instead. | 1.3.6.1.4.1.34097.9.77.1.1.36 | IpAddress | read-only | current |
| mUPSPresent OBJECT-TYPE Checks if a UPS is present. | 1.3.6.1.4.1.34097.9.77.1.1.37 | Unsigned32 (0..1) | read-only | current |
| mUPSStatus OBJECT-TYPE Gets the working status of a UPS (if its working on its batteries or not). | 1.3.6.1.4.1.34097.9.77.1.1.38 | Unsigned32 | read-only | current |
| mUPSEstimatedRunTime OBJECT-TYPE Gets the estimated run time of a UPS. (unit: min) | 1.3.6.1.4.1.34097.9.77.1.1.39 | Unsigned32 (0..65535) | read-only | current |
| mUPSBatteryLevel OBJECT-TYPE The current UPS battery level. (unit: 0.1%) | 1.3.6.1.4.1.34097.9.77.1.1.40 | Utenth (0..1000) | read-only | current |
| mHighCurrent OBJECT-TYPE The current for high values (unit: 0.1A) | 1.3.6.1.4.1.34097.9.77.1.1.41 | Stenth | read-only | current |
| mUpsCommunicationStatus OBJECT-TYPE Status information of communication with the UPS | 1.3.6.1.4.1.34097.9.77.1.1.42 | Unsigned32 (0..1) | read-only | current |
| mHighPower OBJECT-TYPE The power for high values (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.77.1.1.43 | Shundredth (-32768..32767) | read-only | current |
| mTotalHighCurrent OBJECT-TYPE The current for high values (unit: 0.1A) | 1.3.6.1.4.1.34097.9.77.1.1.44 | Stenth (0..65535) | read-only | current |
| mTotalHighPower OBJECT-TYPE The power for high values (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.77.1.1.45 | Shundredth (-32768..32767) | read-only | current |
| mPositiveEnergy OBJECT-TYPE Gets the positive energy used by an outlet. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.77.1.1.46 | Uthousandth (0..4294967295) | read-only | current |
| mNegativeEnergy OBJECT-TYPE Gets the negative energy used by an outlet. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.77.1.1.47 | Uthousandth (0..4294967295) | read-only | current |
| mTotalPositiveEnergy OBJECT-TYPE Gets the positive energy of the module. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.77.1.1.48 | Uthousandth (0..4294967295) | read-only | current |
| mTotalNegativeEnergy OBJECT-TYPE Gets the negative energy of the module. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.77.1.1.49 | Uthousandth (0..4294967295) | read-only | current |
| mCloudStatus OBJECT-TYPE Gets the status of the connection with the cloud. 0 = Idle state; 1 = Disabled; 2 = Initialising; 3 = Initialising - No connection; 4 = Initialising - No key; 5 = Connection Ok; 6 = Connection Failed; 7 = Connection Failed - No key. | 1.3.6.1.4.1.34097.9.77.1.1.56 | Unsigned32 (0..255) | read-only | current |
| mStatus OBJECT-TYPE status of a module | 1.3.6.1.4.1.34097.9.77.1.1.1000 | Unsigned32 (0..65535) | read-only | current |
| mModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.77.1.1.10001 | DisplayString | read-write | current |
| mFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.77.1.1.10002 | Version | read-only | current |
| mHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.77.1.1.10003 | Version | read-only | current |
| mFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.77.1.1.10004 | DisplayString | read-only | current |
| mHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.77.1.1.10005 | DisplayString | read-only | current |
| mRackName OBJECT-TYPE Gets, sets or defaults the name of the rack. | 1.3.6.1.4.1.34097.9.77.1.1.10006 | DisplayString | read-write | current |
| mRackPosition OBJECT-TYPE Gets, sets or defaults the position in the rack. | 1.3.6.1.4.1.34097.9.77.1.1.10007 | DisplayString | read-write | current |
| mIPAddress OBJECT-TYPE Gets, sets or defaults the IP address (when DHCP is disabled). | 1.3.6.1.4.1.34097.9.77.1.1.10011 | IpAddress | read-write | current |
| mSubNetMask OBJECT-TYPE Gets, sets or defaults the subnet mask (when DHCP is disabled). | 1.3.6.1.4.1.34097.9.77.1.1.10012 | IpAddress | read-write | current |
| mStdGateWay OBJECT-TYPE Gets, sets or defaults the standard gateway (when DHCP is disabled). | 1.3.6.1.4.1.34097.9.77.1.1.10013 | IpAddress | read-write | current |
| mDnsServer OBJECT-TYPE Gets, sets or defaults the IP address of the used DNS server (when DHCP is disabled). | 1.3.6.1.4.1.34097.9.77.1.1.10014 | IpAddress | read-write | current |
| mMAC OBJECT-TYPE Gets the MAC address of a master module. | 1.3.6.1.4.1.34097.9.77.1.1.10015 | MacAddress | read-only | current |
| mDHCPEnable OBJECT-TYPE Enables, disables or defaults DHCP. Set to 1 to enable DHCP, or 0 to disable DHCP. | 1.3.6.1.4.1.34097.9.77.1.1.10016 | Unsigned32 (0..1) | read-write | current |
| mNTPServer OBJECT-TYPE Gets, sets or defaults the NTP (Network Time Protocol) server IP address. | 1.3.6.1.4.1.34097.9.77.1.1.10017 | IpAddress | read-write | current |
| mUseDefaultNTPServer OBJECT-TYPE Enables, disables or defaults the usage of the default NTP (Network Time Protocol) server (pool.ntp.org). | 1.3.6.1.4.1.34097.9.77.1.1.10018 | Unsigned32 (0..1) | read-write | current |
| mUseNTP OBJECT-TYPE Enables, disables or defaults NTP (Network Time Protocol). Set to 1 to enable NTP, or 0 to disable NTP. | 1.3.6.1.4.1.34097.9.77.1.1.10019 | Unsigned32 (0..1) | read-write | current |
| mSNMPTrapRecvIP OBJECT-TYPE Gets, sets or defaults the SNMP trap receiver IP address. | 1.3.6.1.4.1.34097.9.77.1.1.10020 | IpAddress | read-write | current |
| mSNMPTrapRecvPort OBJECT-TYPE Gets, sets or defaults the SNMP tap receiver port. | 1.3.6.1.4.1.34097.9.77.1.1.10021 | Unsigned32 (0..65535) | read-write | current |
| mSNMPControl OBJECT-TYPE Enables, disables or defaults write access over SNMP. Set to 1 to disable write access, or 0 to enable write access. | 1.3.6.1.4.1.34097.9.77.1.1.10024 | Unsigned32 (0..1) | read-write | current |
| mECSServer OBJECT-TYPE Gets, sets or defaults the ECS (Energy Cloud Sentinel) server IP address. | 1.3.6.1.4.1.34097.9.77.1.1.10028 | IpAddress | read-write | current |
| mUseECSServer OBJECT-TYPE Enables, disables or defaults the use of an ECS (Energy Cloud Sentinel) server. Set to 1 to enable or 0 to disable. | 1.3.6.1.4.1.34097.9.77.1.1.10029 | Unsigned32 (0..1) | read-write | current |
| mDisplayLock OBJECT-TYPE Gets, sets or defaults the display lock. If the display is locked, you can still view information on the display, but you are not allowed to change settings through the menu system. | 1.3.6.1.4.1.34097.9.77.1.1.10031 | Unsigned32 (0..255) | read-write | current |
| mDisplayTimeOn OBJECT-TYPE Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min) | 1.3.6.1.4.1.34097.9.77.1.1.10032 | Unsigned32 (0..255) | read-write | current |
| mMaxVoltageWarning OBJECT-TYPE Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.77.1.1.10047 | Uhundredth (0..65535) | read-write | current |
| mMinVoltageWarning OBJECT-TYPE Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.77.1.1.10049 | Uhundredth (0..65535) | read-write | current |
| mMinTemperatureWarning OBJECT-TYPE Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.77.1.1.10052 | Utenth (2232..4732) | read-write | current |
| mMaxTemperatureWarning OBJECT-TYPE Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.77.1.1.10053 | Utenth (2232..4732) | read-write | current |
| mGeneralEventEnable OBJECT-TYPE Gets, sets or defaults general events. If set to 0, no events will be generated. Set to 1 to generate events on media indicated by the event bitfields. | 1.3.6.1.4.1.34097.9.77.1.1.10074 | EVENTFLAGS | read-write | current |
| mSNMPSysContact OBJECT-TYPE Gets, sets or defaults the SNMP contact information. | 1.3.6.1.4.1.34097.9.77.1.1.10075 | DisplayString | read-write | current |
| mCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10078 | EVENTFLAGS | read-write | current |
| mPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the power warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10080 | EVENTFLAGS | read-write | current |
| mTotalCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the total outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10082 | EVENTFLAGS | read-write | current |
| mTotalPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the total power warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10084 | EVENTFLAGS | read-write | current |
| mVoltageWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the voltage warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10086 | EVENTFLAGS | read-write | current |
| mTemperatureWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the temperature warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10087 | EVENTFLAGS | read-write | current |
| mDisplayBrightness OBJECT-TYPE Gets, sets or defaults the display brightness (if supported). | 1.3.6.1.4.1.34097.9.77.1.1.10098 | Unsigned32 (0..255) | read-write | current |
| mECSServerPort OBJECT-TYPE Gets, sets or defaults the ECS (Energy Cloud Sentinel) server port. | 1.3.6.1.4.1.34097.9.77.1.1.10106 | Unsigned32 (0..65535) | read-write | current |
| mExternalSensorLabel OBJECT-TYPE Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors. | 1.3.6.1.4.1.34097.9.77.1.1.10109 | DisplayString | read-write | current |
| mHttpsOnly OBJECT-TYPE Enables or disables the use of HTTPS (secure HTTP). Set to 1 to enable HTTPS only, or 0 to also enable HTTP. | 1.3.6.1.4.1.34097.9.77.1.1.10127 | Unsigned32 (0..1) | read-write | current |
| mTelnetSsl OBJECT-TYPE Enables or disables the use of Telnet SSL (secure Telnet). Set to 1 to enable Telnet SSL, or 0 to disable Telnet SSL). | 1.3.6.1.4.1.34097.9.77.1.1.10128 | Unsigned32 (0..1) | read-write | current |
| mCookieTimeToLive OBJECT-TYPE The TTL (Time To Live) of the website cookie. (unit: min) | 1.3.6.1.4.1.34097.9.77.1.1.10130 | Unsigned32 (0..65535) | read-write | current |
| mLineCurrentWarningThreshold OBJECT-TYPE Gets, sets the warning threshold of the linecurrent. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.10131 | Uthousandth (0..65535) | read-write | current |
| mLineCurrentOffThreshold OBJECT-TYPE Gets, sets the off threshold of the linecurrent. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.10132 | Uthousandth (0..65535) | read-write | current |
| mLineCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the linecurrent warning level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10133 | EVENTFLAGS | read-write | current |
| mLineCurrentOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the linecurrent off level is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10134 | EVENTFLAGS | read-write | current |
| mFuseCurrentWarningThreshold OBJECT-TYPE Gets, sets or defaults the maximum current warning threshold per fuse. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.10142 | Uthousandth (0..32000) | read-write | current |
| mFuseCurrentOffThreshold OBJECT-TYPE Gets, sets or defaults the maximum current off threshold per fuse. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.77.1.1.10143 | Uthousandth (0..32000) | read-write | current |
| mFuseCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the fusecurrent warning threshold is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10144 | EVENTFLAGS | read-write | current |
| mFuseCurrentOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the fusecurrent off threshold is exceeded. | 1.3.6.1.4.1.34097.9.77.1.1.10145 | EVENTFLAGS | read-write | current |
| mDeviceID OBJECT-TYPE The ID of the device. | 1.3.6.1.4.1.34097.9.77.1.1.10150 | DisplayString | read-only | current |
| mDeviceVersion OBJECT-TYPE The version of the device. | 1.3.6.1.4.1.34097.9.77.1.1.10151 | Version | read-only | current |
| mSysName OBJECT-TYPE The full name of the device. | 1.3.6.1.4.1.34097.9.77.1.1.10152 | DisplayString | read-only | current |
| mElectricalTopology OBJECT-TYPE Gets the electrical topology of the unit. | 1.3.6.1.4.1.34097.9.77.1.1.10153 | Unsigned32 (0..2) | read-only | current |
| mFusePortTopology OBJECT-TYPE Gets the topology between the outlets and fuses. | 1.3.6.1.4.1.34097.9.77.1.1.10154 | Unsigned32 (0..6) | read-only | current |
| mLineFuseTopology OBJECT-TYPE Gets the topology between the inlet (cable or connection) and the fuses. | 1.3.6.1.4.1.34097.9.77.1.1.10155 | Unsigned32 (0..3) | read-only | current |
| mSSOIPAddress OBJECT-TYPE Gets, sets the IP address of an SSO (Smart Style Office). | 1.3.6.1.4.1.34097.9.77.1.1.10156 | IpAddress | read-write | current |
| mSSOLoginCredentials OBJECT-TYPE Gets, sets the login credentials of an SSO (Smart Style Office). | 1.3.6.1.4.1.34097.9.77.1.1.10157 | DisplayString | read-write | current |
| mSSOGracefullShutdown OBJECT-TYPE Gets, sets the string to send if the UPS' battery level is below the set threshold. | 1.3.6.1.4.1.34097.9.77.1.1.10158 | DisplayString | read-write | current |
| mUPSWarningLevel OBJECT-TYPE Gets, sets or defaults the graceful shutdown threshold of a UPS. | 1.3.6.1.4.1.34097.9.77.1.1.10159 | Utenth (0..1000) | read-write | current |
| mUPSOffLevel OBJECT-TYPE Gets, sets or defaults the threshold of a UPS to set outlets off. | 1.3.6.1.4.1.34097.9.77.1.1.10160 | Utenth (0..1000) | read-write | current |
| mMaxHighCurrentWarning OBJECT-TYPE Gets sets or defaults the maximum high current warning level. (unit: 0.1A) | 1.3.6.1.4.1.34097.9.77.1.1.10165 | Stenth (-32768..32767) | read-write | current |
| mUpsMonitoringProtocol OBJECT-TYPE Disables/Enables UPS monitoring and selects the protocol used for UPS monitoring. 0 = Disabled; 1 = Use old APC protocol | 1.3.6.1.4.1.34097.9.77.1.1.10167 | Unsigned32 (0..1) | read-write | current |
| mUpsEmergencyThreshold OBJECT-TYPE When the UPS battery level goes below this threshold a shutdown request will be sent to all agents (unit: 0.1%) | 1.3.6.1.4.1.34097.9.77.1.1.10168 | Utenth (0..1000) | read-write | current |
| mUpsRecoveryThreshold OBJECT-TYPE When the UPS battery level goes above this threshold a outlets will be powered on as configured by the user (unit: 0.1%) | 1.3.6.1.4.1.34097.9.77.1.1.10169 | Utenth (0..1000) | read-write | current |
| mUpsEventFlags OBJECT-TYPE Event flags for events related to the UPS monitoring | 1.3.6.1.4.1.34097.9.77.1.1.10170 | EVENTFLAGS | read-write | current |
| mRecoveryPowerThreshold OBJECT-TYPE When the UPS was on battery and it went below UPSEMERGTHRES, the outlets that have a load below the RECOVPOWERTHRES will be power cycled once the UPS is back on mains power and exceeds UPSRECOVTHRES (unit: W) | 1.3.6.1.4.1.34097.9.77.1.1.10171 | Unsigned32 (20..4000) | read-write | current |
| mMinHighCurrentWarning OBJECT-TYPE Gets sets or defaults the minimum high current warning level. (unit: 0.1A) | 1.3.6.1.4.1.34097.9.77.1.1.10176 | Stenth (-32768..32767) | read-write | current |
| mMinHighPowerWarning OBJECT-TYPE Gets sets or defaults the power min high current warning level. (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.77.1.1.10177 | Shundredth (-32768..32767) | read-write | current |
| mMaxHighPowerWarning OBJECT-TYPE Gets sets or defaults the power max high current warning level. (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.77.1.1.10178 | Shundredth (-32768..32767) | read-write | current |
| mHeartbeatInterval OBJECT-TYPE Interval (in seconds) between 2 heartbeat SNMP traps, Set to 0 to disable (unit: s) | 1.3.6.1.4.1.34097.9.77.1.1.10179 | Unsigned32 (0..255) | read-write | current |
| mMinTotalHighCurrentWarning OBJECT-TYPE Gets sets or defaults the maximum high current warning level. (unit: 0.1A) | 1.3.6.1.4.1.34097.9.77.1.1.10180 | Stenth (-32768..32767) | read-write | current |
| mMaxTotalHighCurrentWarning OBJECT-TYPE Gets sets or defaults the maximum high current warning level. (unit: 0.1A) | 1.3.6.1.4.1.34097.9.77.1.1.10181 | Stenth (-32768..32767) | read-write | current |
| mMinTotalHighPowerWarning OBJECT-TYPE Gets sets or defaults the power min high current warning level. (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.77.1.1.10182 | Shundredth (-32768..32767) | read-write | current |
| mMaxTotalHighPowerWarning OBJECT-TYPE Gets sets or defaults the power max high current warning level. (unit: 0.01kW) | 1.3.6.1.4.1.34097.9.77.1.1.10183 | Shundredth (-32768..32767) | read-write | current |
| mCloudState OBJECT-TYPE Set if the device needs to push info to the init cloud (val=0) or to the normal cloud (val=1) | 1.3.6.1.4.1.34097.9.77.1.1.10208 | Unsigned32 (0..2) | read-write | current |
| mSensorBias OBJECT-TYPE get or set the DC sensor bias (unit: mV) | 1.3.6.1.4.1.34097.9.77.1.1.10210 | Integer32 (-32768..32767) | read-write | current |
| mDaisyChainDeviceMode OBJECT-TYPE allowed modes: 0: standalone (master without daisy chain slaves) 1: daisy chain master 2: daisy chain slave 1 3: daisy chain slave 2 4: daisy chain slave 3 | 1.3.6.1.4.1.34097.9.77.1.1.10211 | Unsigned32 (0..4) | read-write | current |
| mSNMPTrapUser OBJECT-TYPE Gets, sets or defaults the SNMP tap user out of the user list. | 1.3.6.1.4.1.34097.9.77.1.1.10212 | Unsigned32 (0..4) | read-write | current |
| mUSMUser OBJECT-TYPE Gets, sets or defaults the SNMP USM security user | 1.3.6.1.4.1.34097.9.77.1.1.10213 | DisplayString | read-write | current |
| mUSMAuthPassphrase OBJECT-TYPE Gets, sets or defaults the SNMP USM authentication passphrase (Always MD5) | 1.3.6.1.4.1.34097.9.77.1.1.10214 | DisplayString | read-write | current |
| mUSMPrivPassphrase OBJECT-TYPE Gets, sets or defaults the SNMP USM private passphrase (Always AES) | 1.3.6.1.4.1.34097.9.77.1.1.10215 | DisplayString | read-write | current |
| mSNMPV2GetSetEnable OBJECT-TYPE Gets, sets or defaults the SNMP V2 Enable for get ,set or walk but not for traps. | 1.3.6.1.4.1.34097.9.77.1.1.10216 | Unsigned32 (0..1) | read-write | current |
| mSNMPV3GetSetEnable OBJECT-TYPE Gets, sets or defaults the SNMP V3 Enable for get ,set or walk but not for traps. | 1.3.6.1.4.1.34097.9.77.1.1.10217 | Unsigned32 (0..1) | read-write | current |
| mUSMAuthPassphraseLength OBJECT-TYPE Gets, sets or defaults the SNMP USM authentication passphrase length | 1.3.6.1.4.1.34097.9.77.1.1.10218 | Unsigned32 (0..16) | read-write | current |
| mUSMPrivPassphraseLength OBJECT-TYPE Gets, sets or defaults the SNMP USM private passphrase length | 1.3.6.1.4.1.34097.9.77.1.1.10219 | Unsigned32 (0..16) | read-write | current |
| mSNMPTrapEnable OBJECT-TYPE Gets, sets or defaults the SNMP Trap Enable per trap account | 1.3.6.1.4.1.34097.9.77.1.1.10222 | Unsigned32 (0..1) | read-write | current |
| mLDAPAttribute OBJECT-TYPE Attribute linked to the LDAPFilter | 1.3.6.1.4.1.34097.9.77.1.1.10227 | DisplayString | read-write | current |
| mLDAPPath OBJECT-TYPE Relative Path to be used for the LDAPFilter | 1.3.6.1.4.1.34097.9.77.1.1.10228 | DisplayString | read-write | current |
| mLDAPAdminGroupName OBJECT-TYPE GroupName for Admin Credentials in LDAP | 1.3.6.1.4.1.34097.9.77.1.1.10229 | DisplayString | read-write | current |
| mLDAPRestrictedGroupName OBJECT-TYPE GroupName for Restricted Credentials in LDAP | 1.3.6.1.4.1.34097.9.77.1.1.10230 | DisplayString | read-write | current |
| mLDAPGuestGroupName OBJECT-TYPE GroupName for Guest Credentials in LDAP | 1.3.6.1.4.1.34097.9.77.1.1.10231 | DisplayString | read-write | current |
| mLDAPEnable OBJECT-TYPE Enable or disable login via LDAP credentials | 1.3.6.1.4.1.34097.9.77.1.1.10232 | Unsigned32 (0..1) | read-write | current |
| mLDAPLoginWrapper OBJECT-TYPE Wrapper for login in with LDAP | 1.3.6.1.4.1.34097.9.77.1.1.10233 | DisplayString | read-write | current |
| mLDAPServer OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.77.1.1.10235 | DisplayString | read-write | current |
| mLocalAuthEnable OBJECT-TYPE Set if local authentication is still possible if LDAP is enabled | 1.3.6.1.4.1.34097.9.77.1.1.10236 | Unsigned32 (0..1) | read-write | current |
| masterIndex OBJECT-TYPE Index for the selected Master Module | 1.3.6.1.4.1.34097.9.77.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| masterModuleIndex OBJECT-TYPE Selected Master Module | 1.3.6.1.4.1.34097.9.77.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| powerModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.80 | |||
| ePowerTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.80.1 | not-accessible | current | |
| ePowerEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.80.1.1 | not-accessible | current | |
| pGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.80.1.1.1 | Unsigned32 | read-only | current |
| pSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.80.1.1.2 | Unsigned32 | read-only | current |
| pCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.80.1.1.3 | TimeTicks | read-write | current |
| pVoltage OBJECT-TYPE Gets the voltage of a power module. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.80.1.1.4 | Uhundredth | read-only | current |
| pFrequency OBJECT-TYPE Gets the frequency of the input voltage of a power module. (unit: 0.001Hz) | 1.3.6.1.4.1.34097.9.80.1.1.5 | Uthousandth | read-only | current |
| pCurrent OBJECT-TYPE Gets the current of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.80.1.1.6 | Uthousandth | read-only | current |
| pPower OBJECT-TYPE Gets the power of an outlet. (unit: W) | 1.3.6.1.4.1.34097.9.80.1.1.7 | Unsigned32 | read-only | current |
| pStatePortCur OBJECT-TYPE Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead. | 1.3.6.1.4.1.34097.9.80.1.1.8 | CURPORTSTATE | read-only | current |
| pActiveEnergy OBJECT-TYPE Gets the energy used by an outlet. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.80.1.1.9 | Uthousandth | read-only | current |
| pApparentEnergy OBJECT-TYPE Gets the apparent energy used by an outlet. (unit: 0.001kVAh) | 1.3.6.1.4.1.34097.9.80.1.1.10 | Uthousandth | read-only | current |
| pTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.80.1.1.11 | Utenth | read-only | current |
| pApparentPower OBJECT-TYPE Gets the apparent power of an outlet. (unit: VA) | 1.3.6.1.4.1.34097.9.80.1.1.15 | Unsigned32 | read-only | current |
| pPowerFactor OBJECT-TYPE Gets the power factor of an outlet. (unit: %) | 1.3.6.1.4.1.34097.9.80.1.1.16 | Unsigned32 | read-only | current |
| pTotalCurrent OBJECT-TYPE Gets the total current of a power module. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.80.1.1.17 | Uthousandth | read-only | current |
| pTotalRealPower OBJECT-TYPE Gets the total power level of a power module. (unit: W) | 1.3.6.1.4.1.34097.9.80.1.1.18 | Unsigned32 | read-only | current |
| pTotalApparentPower OBJECT-TYPE Gets the total apparent power of a power module. (unit: VA) | 1.3.6.1.4.1.34097.9.80.1.1.19 | Unsigned32 | read-only | current |
| pTotalActiveEnergy OBJECT-TYPE Gets the total energy of a power module. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.80.1.1.20 | Uthousandth | read-only | current |
| pTotalApparentEnergy OBJECT-TYPE Gets the total apparent energy of a power module. (unit: 0.001kVAh) | 1.3.6.1.4.1.34097.9.80.1.1.21 | Uthousandth | read-only | current |
| pTotalPowerFactor OBJECT-TYPE Gets the total power factor of a power module. (unit: %) | 1.3.6.1.4.1.34097.9.80.1.1.22 | Unsigned32 | read-only | current |
| pTimeOnline OBJECT-TYPE Gets the amount of seconds since the last reset. (unit: s) | 1.3.6.1.4.1.34097.9.80.1.1.24 | Unsigned32 | read-only | current |
| pTotalHarmonicDistortion OBJECT-TYPE total harmonic distortion - outlet (unit: 0.1%) | 1.3.6.1.4.1.34097.9.80.1.1.50 | Utenth (0..1000) | read-only | current |
| pPhase OBJECT-TYPE the phase between 2 waves (unit: degr) | 1.3.6.1.4.1.34097.9.80.1.1.51 | Unsigned32 (0..65535) | read-only | current |
| pBigCurrent OBJECT-TYPE Gets the current of an outlet. (unit: 0.0001A) | 1.3.6.1.4.1.34097.9.80.1.1.52 | Unsigned32 | read-only | current |
| pBigPower OBJECT-TYPE Gets the power of an outlet. (unit: 0.001W) | 1.3.6.1.4.1.34097.9.80.1.1.53 | Uthousandth | read-only | current |
| pBigApparentPower OBJECT-TYPE Gets the apparent power of an outlet. (unit: 0.001VA) | 1.3.6.1.4.1.34097.9.80.1.1.54 | Uthousandth | read-only | current |
| pDetectedPhase OBJECT-TYPE Gives the best matching Phase per currentsensor. Updated every 8s. returnes 255 if no good phaselink is found | 1.3.6.1.4.1.34097.9.80.1.1.55 | Unsigned32 (0..255) | read-only | current |
| pModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.80.1.1.10001 | DisplayString | read-write | current |
| pFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.80.1.1.10002 | Version | read-only | current |
| pHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.80.1.1.10003 | Version | read-only | current |
| pFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.80.1.1.10004 | DisplayString | read-only | current |
| pHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.80.1.1.10005 | DisplayString | read-only | current |
| pPortName OBJECT-TYPE Gets, sets or defaults the name of an outlet. | 1.3.6.1.4.1.34097.9.80.1.1.10034 | DisplayString | read-write | current |
| pPortState OBJECT-TYPE Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead. | 1.3.6.1.4.1.34097.9.80.1.1.10035 | Unsigned32 (0..2) | read-write | current |
| pCurrentPriorOff OBJECT-TYPE Gets, sets or defaults the priority of an outlet. Priority settings are used when 1 or more outlets must be turned off because the total current of a power module was exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10036 | Unsigned32 (1..8) | read-write | current |
| pDelayOn OBJECT-TYPE Gets, sets or defaults the outlet turn-on delay. Use this to reduce inrush current when the Energy Switch boots. (unit: s) | 1.3.6.1.4.1.34097.9.80.1.1.10037 | Unsigned32 (0..65535) | read-write | current |
| pMaxCurrentOff OBJECT-TYPE Gets, sets or defaults the maximum current off level of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.80.1.1.10038 | Uthousandth (100..8000) | read-write | current |
| pMaxCurrentWarning OBJECT-TYPE Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.80.1.1.10039 | Uthousandth (100..8000) | read-write | current |
| pMaxPowerOff OBJECT-TYPE Gets, sets or defaults the maximum power off level of an outlet. (unit: W) | 1.3.6.1.4.1.34097.9.80.1.1.10040 | Unsigned32 (20..2000) | read-write | current |
| pMaxPowerWarning OBJECT-TYPE Gets, sets or defaults the maximum power warning level of an outlet. (unit: W) | 1.3.6.1.4.1.34097.9.80.1.1.10041 | Unsigned32 (20..2000) | read-write | current |
| pMaxTotalCurrentOff OBJECT-TYPE Gets, sets or defaults the total maximum current off level of a power module. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.80.1.1.10042 | Uthousandth (100..16000) | read-write | current |
| pMaxTotalCurrentWarning OBJECT-TYPE Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.80.1.1.10043 | Uthousandth (100..16000) | read-write | current |
| pMaxTotalPowerOff OBJECT-TYPE Gets, sets or defaults the maximum total power off level. (unit: W) | 1.3.6.1.4.1.34097.9.80.1.1.10044 | Unsigned32 (20..4000) | read-write | current |
| pMaxTotalPowerWarning OBJECT-TYPE Gets, sets or defaults the maximum total power warning level. (unit: W) | 1.3.6.1.4.1.34097.9.80.1.1.10045 | Unsigned32 (20..4000) | read-write | current |
| pMaxVoltageWarning OBJECT-TYPE Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.80.1.1.10047 | Uhundredth (5000..30000) | read-write | current |
| pMinVoltageWarning OBJECT-TYPE Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.80.1.1.10049 | Uhundredth (5000..30000) | read-write | current |
| pMinTemperatureWarning OBJECT-TYPE Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.80.1.1.10052 | Utenth (2232..4732) | read-write | current |
| pMaxTemperatureWarning OBJECT-TYPE Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.80.1.1.10053 | Utenth (2232..4732) | read-write | current |
| pPortStateEvent OBJECT-TYPE Enables or disables the SNMP trap if the state of an outlet is changed. | 1.3.6.1.4.1.34097.9.80.1.1.10076 | EVENTFLAGS | read-write | current |
| pCurrentOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the outlet current off level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10077 | EVENTFLAGS | read-write | current |
| pCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10078 | EVENTFLAGS | read-write | current |
| pPowerOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the power off level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10079 | EVENTFLAGS | read-write | current |
| pPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the power warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10080 | EVENTFLAGS | read-write | current |
| pTotalCurrentOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the total outlet current off level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10081 | EVENTFLAGS | read-write | current |
| pTotalCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the total outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10082 | EVENTFLAGS | read-write | current |
| pTotalPowerOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the total power off level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10083 | EVENTFLAGS | read-write | current |
| pTotalPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the total power warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10084 | EVENTFLAGS | read-write | current |
| pVoltageWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the voltage warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10086 | EVENTFLAGS | read-write | current |
| pTemperatureWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the temperature warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10087 | EVENTFLAGS | read-write | current |
| pMaxOverheatingOff OBJECT-TYPE Gets, sets or defaults the maximum overheat temperature off level. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.80.1.1.10090 | Utenth (2232..4732) | read-write | current |
| pOverheatingOffEvent OBJECT-TYPE Enables or disables the SNMP trap if the overtemperature off level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10091 | EVENTFLAGS | read-write | current |
| pPowerCycleTime OBJECT-TYPE Gets, sets or defaults the time interval that is used to do a power cycle of an outlet. (unit: s) | 1.3.6.1.4.1.34097.9.80.1.1.10099 | Unsigned32 (0..255) | read-write | current |
| pExternalSensorLabel OBJECT-TYPE Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors. | 1.3.6.1.4.1.34097.9.80.1.1.10109 | DisplayString | read-write | current |
| pMaxOverheatingWarning OBJECT-TYPE Gets, sets or defaults the overheating temperature warning level. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.80.1.1.10121 | Utenth (2232..4732) | read-write | current |
| pOverheatingWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the overheat warning level is exceeded. | 1.3.6.1.4.1.34097.9.80.1.1.10122 | EVENTFLAGS | read-write | current |
| pMicroIntTimeThreshold OBJECT-TYPE The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms) | 1.3.6.1.4.1.34097.9.80.1.1.10135 | Utenth (10..65535) | read-write | current |
| pMicroIntEvent OBJECT-TYPE Enables or disables the SNMP trap if a microinterruption on the voltage is detected. | 1.3.6.1.4.1.34097.9.80.1.1.10136 | EVENTFLAGS | read-write | current |
| pSoftFuseCurrentThreshold OBJECT-TYPE The threshold of the soft fuse is a factor of the maximum nominal current off (unit: A) | 1.3.6.1.4.1.34097.9.80.1.1.10137 | Unsigned32 (0..255) | read-write | current |
| pSoftFuseDelay OBJECT-TYPE The minimum time the current of an outlet must be above the soft fuse current threshold to switch it off. (unit: ms) | 1.3.6.1.4.1.34097.9.80.1.1.10138 | Unsigned32 (0..65535) | read-write | current |
| pSoftFuseEvent OBJECT-TYPE Enables or disables the SNMP trap if a soft fuse is triggered. | 1.3.6.1.4.1.34097.9.80.1.1.10139 | EVENTFLAGS | read-write | current |
| pPhaseShiftEvent OBJECT-TYPE Enables or disables the SNMP trap if a phase shift on the voltage is detected. | 1.3.6.1.4.1.34097.9.80.1.1.10140 | EVENTFLAGS | read-write | current |
| pSchedulePortOnTime OBJECT-TYPE Gets, sets or defaults the time for the scheduler to turn on an outlet. (unit: min) | 1.3.6.1.4.1.34097.9.80.1.1.10146 | Unsigned32 (0..1439) | read-write | current |
| pSchedulePortOffTime OBJECT-TYPE Gets, sets or defaults the time for the scheduler to turn off an outlet. (unit: min) | 1.3.6.1.4.1.34097.9.80.1.1.10147 | Unsigned32 (0..1439) | read-write | current |
| pEnableSchedulePort OBJECT-TYPE Enables or disables the scheduler on an outlet. When enabled the scheduling is repeated daily. | 1.3.6.1.4.1.34097.9.80.1.1.10148 | Unsigned32 (0..1) | read-write | current |
| pBlockSetPortOff OBJECT-TYPE Prevent outlets to be set off (only delay on and powercycle are still possible). | 1.3.6.1.4.1.34097.9.80.1.1.10161 | Unsigned32 (0..1) | read-write | current |
| pSchedulePortChangeEvent OBJECT-TYPE event if a port has changed state because of the scheduler | 1.3.6.1.4.1.34097.9.80.1.1.10166 | EVENTFLAGS | read-write | current |
| pAgentIP OBJECT-TYPE IP address of the agent associated to this outlet | 1.3.6.1.4.1.34097.9.80.1.1.10172 | IpAddress | read-write | current |
| pAgentPort OBJECT-TYPE Network port on which the associated agent will listen | 1.3.6.1.4.1.34097.9.80.1.1.10173 | Unsigned32 (0..65535) | read-write | current |
| pAgentCommunicationEventFlags OBJECT-TYPE Event flags for events related to agent communication | 1.3.6.1.4.1.34097.9.80.1.1.10174 | EVENTFLAGS | read-write | current |
| pAlwaysOn OBJECT-TYPE Outlets marked as Always On can only be power cycled by the user | 1.3.6.1.4.1.34097.9.80.1.1.10175 | Unsigned32 (0..1) | read-write | current |
| pGenericTransducerParameters OBJECT-TYPE sets the slope of the transducer transfer function when the generic transducer type is selected (unit: mA/V) | 1.3.6.1.4.1.34097.9.80.1.1.10190 | Integer32 (2000..2000000000) | read-write | current |
| pMaxBigCurrentWarning OBJECT-TYPE Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A) | 1.3.6.1.4.1.34097.9.80.1.1.10193 | Unsigned32 (100..400000000) | read-write | current |
| pMaxBigPowerWarning OBJECT-TYPE Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W) | 1.3.6.1.4.1.34097.9.80.1.1.10194 | Uthousandth (2000..2000000000) | read-write | current |
| pGroupNumber OBJECT-TYPE Group number per port to group ports | 1.3.6.1.4.1.34097.9.80.1.1.10195 | Unsigned32 (0..5) | read-write | current |
| pPhaseLink OBJECT-TYPE Link the current port with a voltage phase | 1.3.6.1.4.1.34097.9.80.1.1.10196 | Unsigned32 (0..8) | read-write | current |
| pCurrentSensorSelector OBJECT-TYPE Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190. | 1.3.6.1.4.1.34097.9.80.1.1.10197 | Unsigned32 (0..255) | read-write | current |
| pMinBigCurrentWarning OBJECT-TYPE Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A) | 1.3.6.1.4.1.34097.9.80.1.1.10209 | Unsigned32 (0..400000000) | read-write | current |
| powerIndex OBJECT-TYPE Index for the selected Power Module | 1.3.6.1.4.1.34097.9.80.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| powerModuleIndex OBJECT-TYPE Selected Power Module | 1.3.6.1.4.1.34097.9.80.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| measuring3phaseModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.81 | |||
| eMeasuring3PhaseTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.81.1 | not-accessible | current | |
| eMeasuring3PhaseEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.81.1.1 | not-accessible | current | |
| qGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.81.1.1.1 | Unsigned32 | read-only | current |
| qSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.81.1.1.2 | Unsigned32 | read-only | current |
| qCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.81.1.1.3 | TimeTicks | read-write | current |
| qVoltage OBJECT-TYPE Gets the voltage of a power module. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.81.1.1.4 | Uhundredth | read-only | current |
| qFrequency OBJECT-TYPE Gets the frequency of the input voltage of a power module. (unit: 0.001Hz) | 1.3.6.1.4.1.34097.9.81.1.1.5 | Uthousandth | read-only | current |
| qActiveEnergy OBJECT-TYPE Gets the energy used by an outlet. (unit: 0.001kWh) | 1.3.6.1.4.1.34097.9.81.1.1.9 | Uthousandth | read-only | current |
| qApparentEnergy OBJECT-TYPE Gets the apparent energy used by an outlet. (unit: 0.001kVAh) | 1.3.6.1.4.1.34097.9.81.1.1.10 | Uthousandth | read-only | current |
| qTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.81.1.1.11 | Utenth | read-only | current |
| qPowerFactor OBJECT-TYPE Gets the power factor of an outlet. (unit: %) | 1.3.6.1.4.1.34097.9.81.1.1.16 | Unsigned32 | read-only | current |
| qTimeOnline OBJECT-TYPE Gets the amount of seconds since the last reset. (unit: s) | 1.3.6.1.4.1.34097.9.81.1.1.24 | Unsigned32 | read-only | current |
| qIOPort OBJECT-TYPE Gets the state of a digital input. | 1.3.6.1.4.1.34097.9.81.1.1.30 | Unsigned32 (0..1) | read-only | current |
| qTotalHarmonicDistortion OBJECT-TYPE total harmonic distortion - outlet (unit: 0.1%) | 1.3.6.1.4.1.34097.9.81.1.1.50 | Utenth (0..1000) | read-only | current |
| qPhase OBJECT-TYPE the phase between 2 waves (unit: degr) | 1.3.6.1.4.1.34097.9.81.1.1.51 | Unsigned32 (0..65535) | read-only | current |
| qBigCurrent OBJECT-TYPE Gets the current of an outlet. (unit: 0.0001A) | 1.3.6.1.4.1.34097.9.81.1.1.52 | Unsigned32 | read-only | current |
| qBigPower OBJECT-TYPE Gets the power of an outlet. (unit: 0.001W) | 1.3.6.1.4.1.34097.9.81.1.1.53 | Uthousandth | read-only | current |
| qBigApparentPower OBJECT-TYPE Gets the apparent power of an outlet. (unit: 0.001VA) | 1.3.6.1.4.1.34097.9.81.1.1.54 | Uthousandth | read-only | current |
| qStatus OBJECT-TYPE status of a module | 1.3.6.1.4.1.34097.9.81.1.1.1000 | Unsigned32 (0..65535) | read-only | current |
| qModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.81.1.1.10001 | DisplayString | read-write | current |
| qFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.81.1.1.10002 | Version | read-only | current |
| qHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.81.1.1.10003 | Version | read-only | current |
| qFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.81.1.1.10004 | DisplayString | read-only | current |
| qHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.81.1.1.10005 | DisplayString | read-only | current |
| qPortState OBJECT-TYPE Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead. | 1.3.6.1.4.1.34097.9.81.1.1.10035 | Unsigned32 (0..1) | read-write | current |
| qMaxVoltageWarning OBJECT-TYPE Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.81.1.1.10047 | Uhundredth (5000..30000) | read-write | current |
| qMinVoltageWarning OBJECT-TYPE Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.81.1.1.10049 | Uhundredth (5000..30000) | read-write | current |
| qMinTemperatureWarning OBJECT-TYPE Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.81.1.1.10052 | Utenth (2232..4732) | read-write | current |
| qMaxTemperatureWarning OBJECT-TYPE Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | 1.3.6.1.4.1.34097.9.81.1.1.10053 | Utenth (2232..4732) | read-write | current |
| qPortStateEvent OBJECT-TYPE Enables or disables the SNMP trap if the state of an outlet is changed. | 1.3.6.1.4.1.34097.9.81.1.1.10076 | EVENTFLAGS | read-write | current |
| qCurrentWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the outlet current warning level is exceeded. | 1.3.6.1.4.1.34097.9.81.1.1.10078 | EVENTFLAGS | read-write | current |
| qPowerWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the power warning level is exceeded. | 1.3.6.1.4.1.34097.9.81.1.1.10080 | EVENTFLAGS | read-write | current |
| qVoltageWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the voltage warning level is exceeded. | 1.3.6.1.4.1.34097.9.81.1.1.10086 | EVENTFLAGS | read-write | current |
| qTemperatureWarningEvent OBJECT-TYPE Enables or disables the SNMP trap if the temperature warning level is exceeded. | 1.3.6.1.4.1.34097.9.81.1.1.10087 | EVENTFLAGS | read-write | current |
| qMicroIntTimeThreshold OBJECT-TYPE The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms) | 1.3.6.1.4.1.34097.9.81.1.1.10135 | Utenth (10..65535) | read-write | current |
| qMicroIntEvent OBJECT-TYPE Enables or disables the SNMP trap if a microinterruption on the voltage is detected. | 1.3.6.1.4.1.34097.9.81.1.1.10136 | EVENTFLAGS | read-write | current |
| qDeviceID OBJECT-TYPE The ID of the device. | 1.3.6.1.4.1.34097.9.81.1.1.10150 | DisplayString | read-only | current |
| qDeviceVersion OBJECT-TYPE The version of the device. | 1.3.6.1.4.1.34097.9.81.1.1.10151 | Version | read-only | current |
| qMaxBigCurrentWarning OBJECT-TYPE Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A) | 1.3.6.1.4.1.34097.9.81.1.1.10193 | Unsigned32 (100..400000000) | read-write | current |
| qMaxBigPowerWarning OBJECT-TYPE Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W) | 1.3.6.1.4.1.34097.9.81.1.1.10194 | Uthousandth (2000..2000000000) | read-write | current |
| qCurrentSensorSelector OBJECT-TYPE Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190. | 1.3.6.1.4.1.34097.9.81.1.1.10197 | Unsigned32 (0..255) | read-write | current |
| qMinBigCurrentWarning OBJECT-TYPE Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A) | 1.3.6.1.4.1.34097.9.81.1.1.10209 | Unsigned32 (0..400000000) | read-write | current |
| qkWhMode OBJECT-TYPE Set the mode when to count kWh, 0 = always, 1 = only positive, 2= only negative | 1.3.6.1.4.1.34097.9.81.1.1.10234 | Unsigned32 (0..2) | read-write | current |
| measuring3phaseIndex OBJECT-TYPE Index for the selected Measuring3Phase Module | 1.3.6.1.4.1.34097.9.81.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| measuring3phaseModuleIndex OBJECT-TYPE Selected Measuring3Phase Module | 1.3.6.1.4.1.34097.9.81.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| pcModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.85 | |||
| ePCTable OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.85.1 | not-accessible | current | |
| ePCEntry OBJECT-TYPE NO_INFO | 1.3.6.1.4.1.34097.9.85.1.1 | not-accessible | current | |
| uGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.85.1.1.1 | Unsigned32 | read-only | current |
| uSpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.85.1.1.2 | Unsigned32 | read-only | current |
| uCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.85.1.1.3 | TimeTicks | read-write | current |
| uVoltage OBJECT-TYPE Gets the voltage of a power module. (unit: 0.01V) | 1.3.6.1.4.1.34097.9.85.1.1.4 | Uhundredth (0..65535) | read-only | current |
| uCurrent OBJECT-TYPE Gets the current of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.85.1.1.6 | Uthousandth (0..65535) | read-only | current |
| uStatePortCur OBJECT-TYPE Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead. | 1.3.6.1.4.1.34097.9.85.1.1.8 | CURPORTSTATE | read-only | current |
| uTemperature OBJECT-TYPE Gets the current temperature of a temperature sensor. (unit: 0.1K) | 1.3.6.1.4.1.34097.9.85.1.1.11 | Utenth (2232..4732) | read-only | current |
| uHumidity OBJECT-TYPE Gets the relative humidity. (unit: 0.1RH) | 1.3.6.1.4.1.34097.9.85.1.1.12 | Utenth (0..1000) | read-only | current |
| uModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.85.1.1.10001 | DisplayString | read-write | current |
| uFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.85.1.1.10002 | Version | read-only | current |
| uHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.85.1.1.10003 | Version | read-only | current |
| uFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.85.1.1.10004 | DisplayString | read-only | current |
| uHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.85.1.1.10005 | DisplayString | read-only | current |
| uPortState OBJECT-TYPE Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead. | 1.3.6.1.4.1.34097.9.85.1.1.10035 | Unsigned32 (0..1) | read-write | current |
| pcIndex OBJECT-TYPE Index for the selected PC Module | 1.3.6.1.4.1.34097.9.85.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| pcModuleIndex OBJECT-TYPE Selected PC Module | 1.3.6.1.4.1.34097.9.85.1.1.65538 | Integer32 (1..8) | not-accessible | current |
| testmoduleModule OBJECT-IDENTITY | 1.3.6.1.4.1.34097.9.89 | |||
| eTestModuleTable OBJECT-TYPE Module to test the R-bus | 1.3.6.1.4.1.34097.9.89.1 | not-accessible | current | |
| eTestModuleEntry OBJECT-TYPE Module to test the R-bus | 1.3.6.1.4.1.34097.9.89.1.1 | not-accessible | current | |
| yGeneralModuleStatus OBJECT-TYPE General status of a module. | 1.3.6.1.4.1.34097.9.89.1.1.1 | Unsigned32 | read-only | current |
| ySpecificModuleStatus OBJECT-TYPE Specific status of a module. | 1.3.6.1.4.1.34097.9.89.1.1.2 | Unsigned32 | read-only | current |
| yCurrentTime OBJECT-TYPE Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | 1.3.6.1.4.1.34097.9.89.1.1.3 | TimeTicks | read-write | current |
| yCurrent OBJECT-TYPE Gets the current of an outlet. (unit: 0.001A) | 1.3.6.1.4.1.34097.9.89.1.1.6 | Uthousandth | read-only | current |
| yStatePortCur OBJECT-TYPE Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead. | 1.3.6.1.4.1.34097.9.89.1.1.8 | CURPORTSTATE | read-only | current |
| yAnalogueInput OBJECT-TYPE Gets the value of an analog input (voltage). (unit: mV) | 1.3.6.1.4.1.34097.9.89.1.1.27 | Unsigned32 | read-only | current |
| yModuleName OBJECT-TYPE Gets, sets or defaults the module name. | 1.3.6.1.4.1.34097.9.89.1.1.10001 | DisplayString | read-write | current |
| yFirmwareVersion OBJECT-TYPE Gets the version of the module's firmware. | 1.3.6.1.4.1.34097.9.89.1.1.10002 | Version | read-only | current |
| yHardwareVersion OBJECT-TYPE Gets the version of a module's hardware. | 1.3.6.1.4.1.34097.9.89.1.1.10003 | Version | read-only | current |
| yFirmwareID OBJECT-TYPE Gets the ID of the module's firmware. | 1.3.6.1.4.1.34097.9.89.1.1.10004 | DisplayString | read-only | current |
| yHardwareID OBJECT-TYPE Gets the ID of a module's hardware. | 1.3.6.1.4.1.34097.9.89.1.1.10005 | DisplayString | read-only | current |
| testmoduleIndex OBJECT-TYPE Index for the selected TestModule Module | 1.3.6.1.4.1.34097.9.89.1.1.65537 | Integer32 (1..8) | not-accessible | current |
| testmoduleModuleIndex OBJECT-TYPE Selected TestModule Module | 1.3.6.1.4.1.34097.9.89.1.1.65538 | Integer32 (1..8) | not-accessible | current |
Notifications
| Name | OID | Status |
|---|---|---|
| errorValueTooHighRaised NOTIFICATION-TYPE This trap is sent when an element goes above the specified error threshold indicating the maximum value for this element | 1.3.6.1.4.1.34097.9.0.16 | current |
| errorValueTooLowRaised NOTIFICATION-TYPE This trap is sent when an element goes below the specified error threshold indicating the minimum value for this element | 1.3.6.1.4.1.34097.9.0.17 | current |
| errorRaised NOTIFICATION-TYPE This trap is sent when an element gets into an error state | 1.3.6.1.4.1.34097.9.0.18 | current |
| errorValueTooHighCleared NOTIFICATION-TYPE This trap is sent when an element goes below the specified error threshold indicating the maximum value for this element | 1.3.6.1.4.1.34097.9.0.19 | current |
| errorValueTooLowCleared NOTIFICATION-TYPE This trap is sent when an element goes above the specified error threshold indicating the minimum value for this element | 1.3.6.1.4.1.34097.9.0.20 | current |
| errorCleared NOTIFICATION-TYPE This trap is sent when an element recovers from an error state | 1.3.6.1.4.1.34097.9.0.21 | current |
| warningValueTooHighRaised NOTIFICATION-TYPE This trap is sent when an element goes above the specified warning threshold indicating the maximum value for this element | 1.3.6.1.4.1.34097.9.0.48 | current |
| warningValueTooLowRaised NOTIFICATION-TYPE This trap is sent when an element goes below the specified warning threshold indicating the minimum value for this element | 1.3.6.1.4.1.34097.9.0.49 | current |
| warningRaised NOTIFICATION-TYPE This trap is sent when an element gets into an warning state | 1.3.6.1.4.1.34097.9.0.50 | current |
| warningValueTooHighCleared NOTIFICATION-TYPE This trap is sent when an element goes below the specified warning threshold indicating the maximum value for this element | 1.3.6.1.4.1.34097.9.0.51 | current |
| warningValueTooLowCleared NOTIFICATION-TYPE This trap is sent when an element goes above the specified warning threshold indicating the minimum value for this element | 1.3.6.1.4.1.34097.9.0.52 | current |
| warningCleared NOTIFICATION-TYPE This trap is sent when an element recovers from an warning state | 1.3.6.1.4.1.34097.9.0.53 | current |
| warningMicroInterruption NOTIFICATION-TYPE This event is raised when a micro interruption is detected above a threshold time | 1.3.6.1.4.1.34097.9.0.54 | current |
| warningPhaseShift NOTIFICATION-TYPE This event is raised when a phase shift is detected above a threshold | 1.3.6.1.4.1.34097.9.0.55 | current |
| infoValueTooHighRaised NOTIFICATION-TYPE This trap is sent when an element goes above a specified threshold indicating the maximum value for this element | 1.3.6.1.4.1.34097.9.0.80 | current |
| infoValueTooLowRaised NOTIFICATION-TYPE This trap is sent when an element goes below a specified threshold indicating the minimum value for this element | 1.3.6.1.4.1.34097.9.0.81 | current |
| infoRaised NOTIFICATION-TYPE This trap is sent when an element gets into a specific state | 1.3.6.1.4.1.34097.9.0.82 | current |
| infoValueTooHighCleared NOTIFICATION-TYPE This trap is sent when an element goes below a specified threshold indicating the maximum value for this element | 1.3.6.1.4.1.34097.9.0.83 | current |
| infoValueTooLowCleared NOTIFICATION-TYPE This trap is sent when an element goes above a specified threshold indicating the minimum value for this element | 1.3.6.1.4.1.34097.9.0.84 | current |
| infoCleared NOTIFICATION-TYPE This trap is sent when an element recovers from a specific state | 1.3.6.1.4.1.34097.9.0.85 | current |
| infoPortStateChanged NOTIFICATION-TYPE This trap is sent when a port changes state for any reason | 1.3.6.1.4.1.34097.9.0.96 | current |
| infoReset NOTIFICATION-TYPE This trap is sent when a module is reboot | 1.3.6.1.4.1.34097.9.0.97 | current |
| infoUpgrade NOTIFICATION-TYPE This trap is sent when upgrade or downgrade of firmware is completed | 1.3.6.1.4.1.34097.9.0.98 | current |
| infoPortSchedule NOTIFICATION-TYPE This trap is sent when a port changes state because of a scheduling | 1.3.6.1.4.1.34097.9.0.99 | current |
| infoHeartbeat NOTIFICATION-TYPE This trap is sent when a heartbeat has occurred | 1.3.6.1.4.1.34097.9.0.100 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| esRacktivityMIBGroup OBJECT-GROUP All accessible objects in a Racktivity device | 1.3.6.1.4.1.34097.9.2.1.1 | current |
| esRacktivityNotificationGroup NOTIFICATION-GROUP All notification that can be sent out by a Racktivity device | 1.3.6.1.4.1.34097.9.2.1.2 | current |
| esRacktivityConpliance MODULE-COMPLIANCE The compliance statements for a Racktivity device. | 1.3.6.1.4.1.34097.9.2.2.1 | current |