MIBs Depot

ENVIRONMENT-MIB

Registered at
1.3.6.1.4.1.562.73.1.1.1.3
Last updated
1900-08-18 00:00
Organization
Nortel Networks
Revisions
1900-08-18 00:00
Namespace
nortel
Source file
ENVIRONMENT-MIB
Digest
sha256:c0ab933beddb00dbf6fbe521bf8cadff9618cd476567b65582e6e6ac1a5fc3d1

Contact

Nortel Networks 8200 Dixie Road Brampton, Ontario L6T 5P6 Canada 1-800-4Nortel www.nortelnetworks.com

Imports

FromSymbols
NT-ENTERPRISE-DATA-MIBntEnterpriseDataTasmanMgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENVIRONMENT-MIB
NORTEL-MIB
NT-ENTERPRISE-DATA-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
EnvInstalled
TEXTUAL-CONVENTION
Installed flag for power supply.
current
EnvState
TEXTUAL-CONVENTION
Represents the state of a device being monitored.
current
EnvStatus
TEXTUAL-CONVENTION
Installed flag for power supply.
current
EnvType
TEXTUAL-CONVENTION
Installed flag for power supply.
current

Objects

NameOIDSyntaxAccessStatus
nnenvObjects
OBJECT-IDENTITY
1.3.6.1.4.1.562.73.1.1.1.3.1
nnenvTempSensorGroup
OBJECT-IDENTITY
1.3.6.1.4.1.562.73.1.1.1.3.1.1
nnenvTempSensorValue
OBJECT-TYPE
The Average value of the temperature sensors.
1.3.6.1.4.1.562.73.1.1.1.3.1.1.1Gauge32read-onlycurrent
nnenvTempSensorState
OBJECT-TYPE
The Average status of the temperature sensors.
1.3.6.1.4.1.562.73.1.1.1.3.1.1.2EnvStateread-onlycurrent
nnenvFanTable
OBJECT-TYPE
A list of fan unit entries.
1.3.6.1.4.1.562.73.1.1.1.3.1.2not-accessiblecurrent
nnenvFanEntry
OBJECT-TYPE
Entry containing information about a fan within the chassis.
1.3.6.1.4.1.562.73.1.1.1.3.1.2.1not-accessiblecurrent
nnenvFanUnitIndex
OBJECT-TYPE
The index to access an entry in the table.
1.3.6.1.4.1.562.73.1.1.1.3.1.2.1.1INTEGER (0..1)accessible-for-notifycurrent
nnenvFanState
OBJECT-TYPE
The current state of fan 0, normal/fail.
1.3.6.1.4.1.562.73.1.1.1.3.1.2.1.2EnvStateread-onlycurrent
nnenvPwrsupPowerFailCount
OBJECT-TYPE
Number of failures of either power supply since boot-up.
1.3.6.1.4.1.562.73.1.1.1.3.1.3Integer32read-onlycurrent
nnenvPwrsupTable
OBJECT-TYPE
A list of power supply status information.
1.3.6.1.4.1.562.73.1.1.1.3.1.4not-accessiblecurrent
nnenvPwrsupEntry
OBJECT-TYPE
Entry containing power supply information.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1not-accessiblecurrent
nnenvPwrsupIndex
OBJECT-TYPE
Index to access entry.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.1INTEGER (1..2)accessible-for-notifycurrent
nnenvPwrsupInstalled
OBJECT-TYPE
Power supply installed flag.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.2EnvInstalledread-onlycurrent
nnenvPwrsupStatus
OBJECT-TYPE
Power supply up/down status.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.3EnvStatusread-onlycurrent
nnenvPwrsupType
OBJECT-TYPE
Power supply type.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.4EnvTyperead-onlycurrent
nnenvPwrsupUptime
OBJECT-TYPE
Seconds since power supply came up.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.5Integer32read-onlycurrent
nnenvPwrsupDowntime
OBJECT-TYPE
Seconds since power supply went down.
1.3.6.1.4.1.562.73.1.1.1.3.1.4.1.6Integer32read-onlycurrent
nnenvNotificationEnables
OBJECT-IDENTITY
1.3.6.1.4.1.562.73.1.1.1.3.2
nnenvEnableTemperatureNotification
OBJECT-TYPE
Indicates whether the system produces the envTemperatureNotification. The default is yes. Note: implementation is TBD.
1.3.6.1.4.1.562.73.1.1.1.3.2.1TruthValueread-writecurrent
nnenvEnableFanNotification
OBJECT-TYPE
Indicates whether the system produces the envFanNotification. The default is yes.
1.3.6.1.4.1.562.73.1.1.1.3.2.2TruthValueread-writecurrent
nnenvEnablePowerNotification
OBJECT-TYPE
Indicates whether the system produces the envPowerNotification. The default is yes.
1.3.6.1.4.1.562.73.1.1.1.3.2.3TruthValueread-writecurrent
nnenvNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.562.73.1.1.1.3.3
nnenvTraps
OBJECT-IDENTITY
1.3.6.1.4.1.562.73.1.1.1.3.3.0

Notifications

NameOIDStatus
nnenvTemperatureNotification
NOTIFICATION-TYPE
An envTemeratureNotification is sent if the environmental monitoring detects that the temperature is at a critical state. This may cause the system to shut down. This notification is sent only if envEnableTemperatureNotification is set to true.
1.3.6.1.4.1.562.73.1.1.1.3.3.0.1current
nnenvFanNotification
NOTIFICATION-TYPE
An envFanNotification is sent if the environmental monitoring detects that a fan is in a critical state. This may cause the system to shut down. This notification is sent only if envEnableFanNotification is set to true.
1.3.6.1.4.1.562.73.1.1.1.3.3.0.2current
nnenvPowerSupply1DownNotification
NOTIFICATION-TYPE
An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowerNotification is set to true.
1.3.6.1.4.1.562.73.1.1.1.3.3.0.3current
nnenvPowerSupply1UpNotification
NOTIFICATION-TYPE
An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowerNotification is set to true.
1.3.6.1.4.1.562.73.1.1.1.3.3.0.4current
nnenvPowerSupply2DownNotification
NOTIFICATION-TYPE
An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowerNotification is set to true.
1.3.6.1.4.1.562.73.1.1.1.3.3.0.5current
nnenvPowerSupply2UpNotification
NOTIFICATION-TYPE
An envPowerNotification is sent if the environmental monitoring detects that a power supply has changed status. This notification is sent only if envEnablePowerNotification is set to true.
1.3.6.1.4.1.562.73.1.1.1.3.3.0.6current

Conformance

NameOIDStatus
nnenvironementNotificationGroup
NOTIFICATION-GROUP
THE Envrionment MIB Notification Group
1.3.6.1.4.1.562.73.1.1.1.3.4current