MIBs Depot

ELS100-S24TX2M-MIB

Registered at
1.3.6.1.4.1.52.3.9.1.10.7
Last updated
2002-02-20 22:02
Organization
Enterasys Networks, Inc.
Revisions
2002-08-05 17:53, 2002-02-20 22:02, 1999-10-01 00:00
Namespace
enterasys
Source file
ELS100-S24TX2M-MIB
Digest
sha256:7bd9adff080efc75c5244420668617bc3c9ccc30d500955d13f6e6225a03fe58

Description

The MIB module for ELS100-S24TX2M.

Contact

Enterasys Networks, Inc. 35 Industrial Way, P.O. Box 5005 Rochester, NH 03867-5005 (603) 332-9400 support@enterasys.com http://www.enterasys.com

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, internet, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ELS100-S24TX2M-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
switchInfo
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.1
switchNumber
OBJECT-TYPE
The total number of switches present on this system.
1.3.6.1.4.1.52.3.9.1.10.7.1.1Integer32read-onlycurrent
switchInfoTable
OBJECT-TYPE
Table of descriptive and status information about switches in this system.
1.3.6.1.4.1.52.3.9.1.10.7.1.2not-accessiblecurrent
switchInfoEntry
OBJECT-TYPE
An entry in the table, containing information about a single switch in this system.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1not-accessiblecurrent
swUnitIndex
OBJECT-TYPE
This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.1Integer32not-accessiblecurrent
swMainBoardHwVer
OBJECT-TYPE
Hardware version of the main board.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.2DisplayString (SIZE(0..20))read-onlycurrent
swMainBoardFwVer
OBJECT-TYPE
Firmware version of the main board.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.3DisplayString (SIZE(0..20))read-onlycurrent
swAgentBoardHwVer
OBJECT-TYPE
Hardware version of the agent board.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.4DisplayString (SIZE(0..20))read-onlycurrent
swAgentBoardFwVer
OBJECT-TYPE
Firmware version of the agent board.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.5DisplayString (SIZE(0..20))read-onlycurrent
swAgentBoardPOSTCodeVer
OBJECT-TYPE
POST code version of the agent board.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.6DisplayString (SIZE(0..20))read-onlycurrent
swPortNumber
OBJECT-TYPE
The total port number of this switch (including expansion slot).
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.7Integer32read-onlycurrent
swPowerStatus
OBJECT-TYPE
Indicates the switch using internalPower(1), redundantPower(2) or both(3)
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.8INTEGER {internalPower(1), redundantPower(2), internalAndRedundantPower(3)}read-onlycurrent
swExpansionSlot1
OBJECT-TYPE
Type of expansion module in this switch slot 1.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.9INTEGER {hundredBaseFX2Port(1), thousandBaseSX(2), stackingModule4GB(3), hundredBaseFX1Port(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), stackingModule2GB(8), other(9), notPresent(10)}read-onlycurrent
swExpansionSlot2
OBJECT-TYPE
Type of expansion module in this switch slot 2.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.10INTEGER {hundredBaseFX2Port(1), thousandBaseSX(2), stackingModule4GB(3), hundredBaseFX1Port(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), stackingModule2GB(8), other(9), notPresent(10)}read-onlycurrent
swRoleInSystem
OBJECT-TYPE
Indicates the switch is master(1), backupMaster(2) or slave(3) in this system.
1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.11INTEGER {master(1), backupMaster(2), slave(3)}read-onlycurrent
switchOIDTable
OBJECT-TYPE
Table of System Object Identifiers for switches in this system.
1.3.6.1.4.1.52.3.9.1.10.7.1.3not-accessiblecurrent
switchOIDEntry
OBJECT-TYPE
An entry in the table, containing System Object Identifier for a single switch in this system.
1.3.6.1.4.1.52.3.9.1.10.7.1.3.1not-accessiblecurrent
switchOIDIndex
OBJECT-TYPE
This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber. Index value 1 always represents the Master in a stacked configuration and the only device in a standalone configuration. Subsequent indices are sequential with the lowest number representing the Slave nearest the Master and so on.
1.3.6.1.4.1.52.3.9.1.10.7.1.3.1.1INTEGER (1..65535)not-accessiblecurrent
switchOIDValue
OBJECT-TYPE
This object contains the System Object Identifier that uniquely identifies the type of switch.
1.3.6.1.4.1.52.3.9.1.10.7.1.3.1.2OBJECT IDENTIFIERread-onlycurrent
switchPortMgt
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.2
switchPortMgtTable
OBJECT-TYPE
Table of descriptive and status information about configuration of each switch ports (including expansion slot) in this system.
1.3.6.1.4.1.52.3.9.1.10.7.2.1not-accessiblecurrent
switchPortMgtEntry
OBJECT-TYPE
An entry in the table, containing information about configuration in one switch port of the switch.
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1not-accessiblecurrent
swPortMgtIndex
OBJECT-TYPE
This object identifies the port within the switch for which this entry contains information.
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.1Integer32not-accessiblecurrent
swPortMgtPortType
OBJECT-TYPE
Indicates the port type is tenBaseT/hundredBaseTX(1), hundredBaseFX(2) or thousandBaseSX(3).
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.2INTEGER {hundredBaseTX(1), hundredBaseFX(2), thousandBaseSX(3)}read-onlycurrent
swPortMgtSpeedDpxAdmin
OBJECT-TYPE
Set the port speed and duplex mode as follows: halfDuplex10(1) - 10Mbps and half duplex mode fullDuplex10(2) - 10Mbps and full duplex mode halfDuplex100(3) - 100Mbps and half duplex mode fullDuplex100(4) - 100Mbps and full duplex mode halfDuplex1000(5) - 1000Mbps and half duplex mode fullDuplex1000(6) - 1000Mbps and full duplex mode autoNegotiation(7) - let the switch to negotiate with the other end of connection. hundredBaseTX port can be set as halfDuplex10(1) fullDuplex10(2) halfDuplex100(3) fullDuplex100(4) autoNegotiation(7) hundredBaseFX port can be set as halfDuplex100(3) fullDuplex100(4) thousandBaseSX port can be set as halfDuplex1000(5) fullDuplex1000(6) autoNegotiation(7) The actual operating speed and duplex of the port is given by swPortMgtSpeedDpxInUse.
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.3INTEGER {halfDuplex10(1), fullDuplex10(2), halfDuplex100(3), fullDuplex100(4), halfDuplex1000(5), fullDuplex1000(6), autoNegotiation(7)}read-writecurrent
swPortMgtSpeedDpxInUse
OBJECT-TYPE
The operating speed and duplex mode of the switched port.
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.4INTEGER {halfDuplex10(1), fullDuplex10(2), halfDuplex100(3), fullDuplex100(4), halfDuplex1000(5), fullDuplex1000(6)}read-onlycurrent
swPortMgtFlowCtrlAdmin
OBJECT-TYPE
(1) Flow control mechanism is enabled. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (3) Flow control mechanism is backPressure. When the port is in fullDuplex mode this flow control mechanism will not function. (4) Flow control mechanism is IEEE 802.3x flow control. When the port is in halfDuplex mode this flow control mechanism will not function. hundredBaseTX and thousandBaseSX port can be set as: enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4). hundredBaseFX port can be set as: enabled(1), disabled(2), backPressure(3). The actual flow control mechanism is used given by swPortMgtFlowCtrlInUse.
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.5INTEGER {enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4)}read-writecurrent
swPortMgtFlowCtrlInUse
OBJECT-TYPE
(1) BackPressure flow control mechanism is used. (2) IEEE 802.3 flow control mechanism is used. (3) Flow control mechanism is disabled.
1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.6INTEGER {backPressure(1), dot3xFlowControl(2), none(3)}read-onlycurrent
systemSTAMgt
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.3
systemSTAStatus
OBJECT-TYPE
Global spanning tree status. (1) Spanning tree protocol is enabled. (2) Spanning tree protocol is disabled.
1.3.6.1.4.1.52.3.9.1.10.7.3.1INTEGER {enabled(1), disabled(2)}read-writecurrent
tftpDownloadMgt
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.4
tftpDownloadServerIP
OBJECT-TYPE
The IP address of a TFTP server from which a firmware image can be downloaded.
1.3.6.1.4.1.52.3.9.1.10.7.4.1IpAddressread-writecurrent
tftpDownloadAgentBoardFwFileName
OBJECT-TYPE
1.3.6.1.4.1.52.3.9.1.10.7.4.2DisplayString (SIZE(0..80))read-writecurrent
tftpDownloadAgentBoardFwDownloadNode
OBJECT-TYPE
Indicates whether a newly upgraded firmware version should write to flash. When this object is temporary(2), following a successful upgrade the system will switch to run the new firmware but will not upgrade the new firmware to flash. That means after a power cycle, system will run the firmware residing the flash. When this object is permanent(1), following a successful firmware upgrade, the flash will be upgraded and the system will automatically switch to run the new firmware.
1.3.6.1.4.1.52.3.9.1.10.7.4.3INTEGER {permanent(1), temporary(2)}read-writecurrent
tftpDownloadStatus
OBJECT-TYPE
Setting this object to active(1) trigger the TFTP download action. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2) when this object is read.
1.3.6.1.4.1.52.3.9.1.10.7.4.4INTEGER {active(1), notActive(2)}read-writecurrent
restartMgt
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.5
restartOptionPOST
OBJECT-TYPE
Setting this object as enabled. The system will do POST when it restart
1.3.6.1.4.1.52.3.9.1.10.7.5.1INTEGER {enabled(1), disabled(2)}read-writecurrent
restartOptionReloadFactoryDefault
OBJECT-TYPE
Setting this object as enabled. The system will do factory reset when it restart
1.3.6.1.4.1.52.3.9.1.10.7.5.2INTEGER {enabled(1), disabled(2)}read-writecurrent
restartOptionKeepIpSetting
OBJECT-TYPE
Setting this object as enabled. The system will keep IP setting when it do factory reset.
1.3.6.1.4.1.52.3.9.1.10.7.5.3INTEGER {enabled(1), disabled(2)}read-writecurrent
restartOptionKeepUserAuthentication
OBJECT-TYPE
Setting this object as enabled. The system will keep user authentication setting when it do factory reset.
1.3.6.1.4.1.52.3.9.1.10.7.5.4INTEGER {enabled(1), disabled(2)}read-writecurrent
restartAction
OBJECT-TYPE
Setting this object to active(1) trigger the system restart. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2) when this object is read.
1.3.6.1.4.1.52.3.9.1.10.7.5.5INTEGER {active(1), notActive(2)}read-writecurrent
portMirrorMgt
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.6
portMirrorStatus
OBJECT-TYPE
Port mirroring function status. (1) mirroring function is enabled. (2) mirroring function is disabled.
1.3.6.1.4.1.52.3.9.1.10.7.6.1INTEGER {enabled(1), disabled(2)}read-writecurrent
portMirrorSnifferPort
OBJECT-TYPE
Linear port number of sniffer port to which all frames to/from mirrored ports are sent. Frames are only mirrored if the portMirrorStatus object is set to enabled(1).
1.3.6.1.4.1.52.3.9.1.10.7.6.2Integer32read-writecurrent
portMirrorMirroredPort
OBJECT-TYPE
Linear port number of mirrored port. The traffic of mirrored port will be 'copied' to sniffer port.
1.3.6.1.4.1.52.3.9.1.10.7.6.3Integer32read-writecurrent
igmpMgt
OBJECT-IDENTITY
1.3.6.1.4.1.52.3.9.1.10.7.7
igmpStatus
OBJECT-TYPE
Parameter to enable or disable IGMP snooping on the device. When enabled, the device will examine IGMP packets and set up filters for IGMP ports. The default is enabled.
1.3.6.1.4.1.52.3.9.1.10.7.7.1INTEGER {enabled(1), disabled(2)}read-writecurrent
igmpQueryCount
OBJECT-TYPE
Maximum number of queries that have not been heard on the system before the system starts taking action to solicit reports(default is 5).
1.3.6.1.4.1.52.3.9.1.10.7.7.2INTEGER (2..16)read-writecurrent
igmpReportDelay
OBJECT-TYPE
Timeout value(mins) between IGMP reports received on a port for an IP Multicast Address that can pass before the system sends an IGMP Query out the port and removes it from the list(default is 5 minutes).
1.3.6.1.4.1.52.3.9.1.10.7.7.3INTEGER (3..10)read-writecurrent