ELS100-S24TX2M-MIB
- Registered at
- 1.3.6.1.4.1.52.3.9.1.10.7
- Last updated
- 2002-02-20 22:02
- Organization
- Enterasys Networks, Inc.
- Revisions
- 2002-08-05 17:53, 2002-02-20 22:02, 1999-10-01 00:00
- Namespace
- enterasys
- Source file
ELS100-S24TX2M-MIB- Digest
sha256:7bd9adff080efc75c5244420668617bc3c9ccc30d500955d13f6e6225a03fe58
Description
The MIB module for ELS100-S24TX2M.
Contact
Enterasys Networks, Inc. 35 Industrial Way, P.O. Box 5005 Rochester, NH 03867-5005 (603) 332-9400 support@enterasys.com http://www.enterasys.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, internet, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ELS100-S24TX2M-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| switchInfo OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.1 | |||
| switchNumber OBJECT-TYPE The total number of switches present on this system. | 1.3.6.1.4.1.52.3.9.1.10.7.1.1 | Integer32 | read-only | current |
| switchInfoTable OBJECT-TYPE Table of descriptive and status information about switches in this system. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2 | not-accessible | current | |
| switchInfoEntry OBJECT-TYPE An entry in the table, containing information about a single switch in this system. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1 | not-accessible | current | |
| swUnitIndex OBJECT-TYPE This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.1 | Integer32 | not-accessible | current |
| swMainBoardHwVer OBJECT-TYPE Hardware version of the main board. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.2 | DisplayString (SIZE(0..20)) | read-only | current |
| swMainBoardFwVer OBJECT-TYPE Firmware version of the main board. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.3 | DisplayString (SIZE(0..20)) | read-only | current |
| swAgentBoardHwVer OBJECT-TYPE Hardware version of the agent board. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.4 | DisplayString (SIZE(0..20)) | read-only | current |
| swAgentBoardFwVer OBJECT-TYPE Firmware version of the agent board. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.5 | DisplayString (SIZE(0..20)) | read-only | current |
| swAgentBoardPOSTCodeVer OBJECT-TYPE POST code version of the agent board. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.6 | DisplayString (SIZE(0..20)) | read-only | current |
| swPortNumber OBJECT-TYPE The total port number of this switch (including expansion slot). | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.7 | Integer32 | read-only | current |
| swPowerStatus OBJECT-TYPE Indicates the switch using internalPower(1), redundantPower(2) or both(3) | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.8 | INTEGER {internalPower(1), redundantPower(2), internalAndRedundantPower(3)} | read-only | current |
| swExpansionSlot1 OBJECT-TYPE Type of expansion module in this switch slot 1. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.9 | INTEGER {hundredBaseFX2Port(1), thousandBaseSX(2), stackingModule4GB(3), hundredBaseFX1Port(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), stackingModule2GB(8), other(9), notPresent(10)} | read-only | current |
| swExpansionSlot2 OBJECT-TYPE Type of expansion module in this switch slot 2. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.10 | INTEGER {hundredBaseFX2Port(1), thousandBaseSX(2), stackingModule4GB(3), hundredBaseFX1Port(4), thousandBaseLX(5), thousandBaseT(6), thousandBaseGBIC(7), stackingModule2GB(8), other(9), notPresent(10)} | read-only | current |
| swRoleInSystem OBJECT-TYPE Indicates the switch is master(1), backupMaster(2) or slave(3) in this system. | 1.3.6.1.4.1.52.3.9.1.10.7.1.2.1.11 | INTEGER {master(1), backupMaster(2), slave(3)} | read-only | current |
| switchOIDTable OBJECT-TYPE Table of System Object Identifiers for switches in this system. | 1.3.6.1.4.1.52.3.9.1.10.7.1.3 | not-accessible | current | |
| switchOIDEntry OBJECT-TYPE An entry in the table, containing System Object Identifier for a single switch in this system. | 1.3.6.1.4.1.52.3.9.1.10.7.1.3.1 | not-accessible | current | |
| switchOIDIndex OBJECT-TYPE This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber. Index value 1 always represents the Master in a stacked configuration and the only device in a standalone configuration. Subsequent indices are sequential with the lowest number representing the Slave nearest the Master and so on. | 1.3.6.1.4.1.52.3.9.1.10.7.1.3.1.1 | INTEGER (1..65535) | not-accessible | current |
| switchOIDValue OBJECT-TYPE This object contains the System Object Identifier that uniquely identifies the type of switch. | 1.3.6.1.4.1.52.3.9.1.10.7.1.3.1.2 | OBJECT IDENTIFIER | read-only | current |
| switchPortMgt OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.2 | |||
| switchPortMgtTable OBJECT-TYPE Table of descriptive and status information about configuration of each switch ports (including expansion slot) in this system. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1 | not-accessible | current | |
| switchPortMgtEntry OBJECT-TYPE An entry in the table, containing information about configuration in one switch port of the switch. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1 | not-accessible | current | |
| swPortMgtIndex OBJECT-TYPE This object identifies the port within the switch for which this entry contains information. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.1 | Integer32 | not-accessible | current |
| swPortMgtPortType OBJECT-TYPE Indicates the port type is tenBaseT/hundredBaseTX(1), hundredBaseFX(2) or thousandBaseSX(3). | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.2 | INTEGER {hundredBaseTX(1), hundredBaseFX(2), thousandBaseSX(3)} | read-only | current |
| swPortMgtSpeedDpxAdmin OBJECT-TYPE Set the port speed and duplex mode as follows: halfDuplex10(1) - 10Mbps and half duplex mode fullDuplex10(2) - 10Mbps and full duplex mode halfDuplex100(3) - 100Mbps and half duplex mode fullDuplex100(4) - 100Mbps and full duplex mode halfDuplex1000(5) - 1000Mbps and half duplex mode fullDuplex1000(6) - 1000Mbps and full duplex mode autoNegotiation(7) - let the switch to negotiate with the other end of connection. hundredBaseTX port can be set as halfDuplex10(1) fullDuplex10(2) halfDuplex100(3) fullDuplex100(4) autoNegotiation(7) hundredBaseFX port can be set as halfDuplex100(3) fullDuplex100(4) thousandBaseSX port can be set as halfDuplex1000(5) fullDuplex1000(6) autoNegotiation(7) The actual operating speed and duplex of the port is given by swPortMgtSpeedDpxInUse. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.3 | INTEGER {halfDuplex10(1), fullDuplex10(2), halfDuplex100(3), fullDuplex100(4), halfDuplex1000(5), fullDuplex1000(6), autoNegotiation(7)} | read-write | current |
| swPortMgtSpeedDpxInUse OBJECT-TYPE The operating speed and duplex mode of the switched port. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.4 | INTEGER {halfDuplex10(1), fullDuplex10(2), halfDuplex100(3), fullDuplex100(4), halfDuplex1000(5), fullDuplex1000(6)} | read-only | current |
| swPortMgtFlowCtrlAdmin OBJECT-TYPE (1) Flow control mechanism is enabled. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (3) Flow control mechanism is backPressure. When the port is in fullDuplex mode this flow control mechanism will not function. (4) Flow control mechanism is IEEE 802.3x flow control. When the port is in halfDuplex mode this flow control mechanism will not function. hundredBaseTX and thousandBaseSX port can be set as: enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4). hundredBaseFX port can be set as: enabled(1), disabled(2), backPressure(3). The actual flow control mechanism is used given by swPortMgtFlowCtrlInUse. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.5 | INTEGER {enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4)} | read-write | current |
| swPortMgtFlowCtrlInUse OBJECT-TYPE (1) BackPressure flow control mechanism is used. (2) IEEE 802.3 flow control mechanism is used. (3) Flow control mechanism is disabled. | 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.6 | INTEGER {backPressure(1), dot3xFlowControl(2), none(3)} | read-only | current |
| systemSTAMgt OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.3 | |||
| systemSTAStatus OBJECT-TYPE Global spanning tree status. (1) Spanning tree protocol is enabled. (2) Spanning tree protocol is disabled. | 1.3.6.1.4.1.52.3.9.1.10.7.3.1 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| tftpDownloadMgt OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.4 | |||
| tftpDownloadServerIP OBJECT-TYPE The IP address of a TFTP server from which a firmware image can be downloaded. | 1.3.6.1.4.1.52.3.9.1.10.7.4.1 | IpAddress | read-write | current |
| tftpDownloadAgentBoardFwFileName OBJECT-TYPE | 1.3.6.1.4.1.52.3.9.1.10.7.4.2 | DisplayString (SIZE(0..80)) | read-write | current |
| tftpDownloadAgentBoardFwDownloadNode OBJECT-TYPE Indicates whether a newly upgraded firmware version should write to flash. When this object is temporary(2), following a successful upgrade the system will switch to run the new firmware but will not upgrade the new firmware to flash. That means after a power cycle, system will run the firmware residing the flash. When this object is permanent(1), following a successful firmware upgrade, the flash will be upgraded and the system will automatically switch to run the new firmware. | 1.3.6.1.4.1.52.3.9.1.10.7.4.3 | INTEGER {permanent(1), temporary(2)} | read-write | current |
| tftpDownloadStatus OBJECT-TYPE Setting this object to active(1) trigger the TFTP download action. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2) when this object is read. | 1.3.6.1.4.1.52.3.9.1.10.7.4.4 | INTEGER {active(1), notActive(2)} | read-write | current |
| restartMgt OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.5 | |||
| restartOptionPOST OBJECT-TYPE Setting this object as enabled. The system will do POST when it restart | 1.3.6.1.4.1.52.3.9.1.10.7.5.1 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| restartOptionReloadFactoryDefault OBJECT-TYPE Setting this object as enabled. The system will do factory reset when it restart | 1.3.6.1.4.1.52.3.9.1.10.7.5.2 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| restartOptionKeepIpSetting OBJECT-TYPE Setting this object as enabled. The system will keep IP setting when it do factory reset. | 1.3.6.1.4.1.52.3.9.1.10.7.5.3 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| restartOptionKeepUserAuthentication OBJECT-TYPE Setting this object as enabled. The system will keep user authentication setting when it do factory reset. | 1.3.6.1.4.1.52.3.9.1.10.7.5.4 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| restartAction OBJECT-TYPE Setting this object to active(1) trigger the system restart. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2) when this object is read. | 1.3.6.1.4.1.52.3.9.1.10.7.5.5 | INTEGER {active(1), notActive(2)} | read-write | current |
| portMirrorMgt OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.6 | |||
| portMirrorStatus OBJECT-TYPE Port mirroring function status. (1) mirroring function is enabled. (2) mirroring function is disabled. | 1.3.6.1.4.1.52.3.9.1.10.7.6.1 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| portMirrorSnifferPort OBJECT-TYPE Linear port number of sniffer port to which all frames to/from mirrored ports are sent. Frames are only mirrored if the portMirrorStatus object is set to enabled(1). | 1.3.6.1.4.1.52.3.9.1.10.7.6.2 | Integer32 | read-write | current |
| portMirrorMirroredPort OBJECT-TYPE Linear port number of mirrored port. The traffic of mirrored port will be 'copied' to sniffer port. | 1.3.6.1.4.1.52.3.9.1.10.7.6.3 | Integer32 | read-write | current |
| igmpMgt OBJECT-IDENTITY | 1.3.6.1.4.1.52.3.9.1.10.7.7 | |||
| igmpStatus OBJECT-TYPE Parameter to enable or disable IGMP snooping on the device. When enabled, the device will examine IGMP packets and set up filters for IGMP ports. The default is enabled. | 1.3.6.1.4.1.52.3.9.1.10.7.7.1 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| igmpQueryCount OBJECT-TYPE Maximum number of queries that have not been heard on the system before the system starts taking action to solicit reports(default is 5). | 1.3.6.1.4.1.52.3.9.1.10.7.7.2 | INTEGER (2..16) | read-write | current |
| igmpReportDelay OBJECT-TYPE Timeout value(mins) between IGMP reports received on a port for an IP Multicast Address that can pass before the system sends an IGMP Query out the port and removes it from the list(default is 5 minutes). | 1.3.6.1.4.1.52.3.9.1.10.7.7.3 | INTEGER (3..10) | read-write | current |