Description

The MIB module for Eaton Sensors.

Contact

http://powerquality.eaton.com

Imports

FromSymbols
EATON-OIDSsensorAgent
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

EATON-OIDS
EATON-SENSOR-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AlarmLevelType
TEXTUAL-CONVENTION
Describes the alarm level.
current
AlarmSeverityType
TEXTUAL-CONVENTION
Describes the alarm severity.
current
AlarmType
TEXTUAL-CONVENTION
Describes the alarm according to a measured value by reference to the triggers.
current
CommunicationStatus
TEXTUAL-CONVENTION
Describes the communication sensor status or probe status.
current
ElevationType
TEXTUAL-CONVENTION
Describes the elevation in the rack.
current
EnableType
TEXTUAL-CONVENTION
Describes enable/disable.
current
PolarityType
TEXTUAL-CONVENTION
Describes the polarity configuration.
current
PositionType
TEXTUAL-CONVENTION
Describes the position by reference to the data center aisle.
current
ProbeConnectionType
TEXTUAL-CONVENTION
Describes the probe connection to the sensor or probe.
current
ResetCommandType
TEXTUAL-CONVENTION
Commands a reset.
current
StateType
TEXTUAL-CONVENTION
Describes the state of a digital input that depends on its measure and the polrity configuration.
current
TemperatureUnitType
TEXTUAL-CONVENTION
Describes the temperature unit used to read/write the temperature data.
current
UnixTimeStamp
TEXTUAL-CONVENTION
Unix time stamp. Measured in seconds since January 1, 1970.
current

Objects

NameOIDSyntaxAccessStatus
sensor
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.1
sensorNotification
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.1.0
sensorCount
OBJECT-TYPE
Number of sensor managed on this device.
1.3.6.1.4.1.534.6.8.1.1.1Integer32read-onlycurrent
sensorIdentificationTable
OBJECT-TYPE
A list of sensor devices identification data. The number of entries is given by sensorCount.
1.3.6.1.4.1.534.6.8.1.1.2not-accessiblecurrent
sensorIdentificationEntry
OBJECT-TYPE
An entry for a sensor device identification.
1.3.6.1.4.1.534.6.8.1.1.2.1not-accessiblecurrent
sensorIndex
OBJECT-TYPE
A unique value for each sensor device. Its value ranges from 1 to sensorCount.
1.3.6.1.4.1.534.6.8.1.1.2.1.1Integer32 (1..3)accessible-for-notifycurrent
sensorUuid
OBJECT-TYPE
A unique uuid value for each sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.2OCTET STRINGread-onlycurrent
sensorConnectionType
OBJECT-TYPE
Sensor connection type with the device that monitors it.
1.3.6.1.4.1.534.6.8.1.1.2.1.3ProbeConnectionTyperead-onlycurrent
sensorAddress
OBJECT-TYPE
Depending of the connection implementation : Modbus Slave Id, BT Mac address, ...
1.3.6.1.4.1.534.6.8.1.1.2.1.4OCTET STRINGread-onlycurrent
sensorMonitoredBy
OBJECT-TYPE
Parent oid device where the sensor is connected to and monitored by.
1.3.6.1.4.1.534.6.8.1.1.2.1.5OBJECT IDENTIFIERread-onlycurrent
sensorManufacturer
OBJECT-TYPE
The vendor name of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.6OCTET STRING (SIZE(1..31))read-onlycurrent
sensorModel
OBJECT-TYPE
The model name of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.7OCTET STRING (SIZE(1..31))read-onlycurrent
sensorPartNumber
OBJECT-TYPE
The catalog part number of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.8OCTET STRING (SIZE(1..31))read-onlycurrent
sensorSerialNumber
OBJECT-TYPE
The serial number of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.9OCTET STRING (SIZE(1..31))read-onlycurrent
sensorFirmwareVersion
OBJECT-TYPE
The firmware version of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.2.1.10OCTET STRING (SIZE(1..31))read-onlycurrent
sensorConfigurationTable
OBJECT-TYPE
A list of sensor devices configuration data. The number of entries is given by sensorCount.
1.3.6.1.4.1.534.6.8.1.1.3not-accessiblecurrent
sensorConfigurationEntry
OBJECT-TYPE
An entry for a sensor device configuration.
1.3.6.1.4.1.534.6.8.1.1.3.1not-accessiblecurrent
sensorName
OBJECT-TYPE
The friendly name of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.3.1.1OCTET STRING (SIZE(1..31))read-writecurrent
sensorLocation
OBJECT-TYPE
The location of the sensor device.
1.3.6.1.4.1.534.6.8.1.1.3.1.2OCTET STRING (SIZE(1..31))read-writecurrent
sensorPosition
OBJECT-TYPE
The Position by reference to the data center aisle.
1.3.6.1.4.1.534.6.8.1.1.3.1.3PositionTyperead-writecurrent
sensorElevation
OBJECT-TYPE
The Elevation in the rack.
1.3.6.1.4.1.534.6.8.1.1.3.1.4ElevationTyperead-writecurrent
sensorUElevation
OBJECT-TYPE
The elevation in the rack in count of U position from the bottom.
1.3.6.1.4.1.534.6.8.1.1.3.1.5Integer32read-writecurrent
sensorMonitoringTable
OBJECT-TYPE
A list of sensor devices monitoring data. The number of entries is given by sensorCount.
1.3.6.1.4.1.534.6.8.1.1.4not-accessiblecurrent
sensorMonitoringEntry
OBJECT-TYPE
An entry for a sensor device monitoring.
1.3.6.1.4.1.534.6.8.1.1.4.1not-accessiblecurrent
sensorStatus
OBJECT-TYPE
Indicates how the sensor is communicating or not.
1.3.6.1.4.1.534.6.8.1.1.4.1.1CommunicationStatusread-onlycurrent
sensorStatusSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the sensor status last change.
1.3.6.1.4.1.534.6.8.1.1.4.1.2UnixTimeStampread-onlycurrent
sensorTemperatureCount
OBJECT-TYPE
Number of temperature probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.3Integer32read-onlycurrent
sensorHumidityCount
OBJECT-TYPE
Number of humidity probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.4Integer32read-onlycurrent
sensorDigitalInputCount
OBJECT-TYPE
Number of digital input probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.5Integer32read-onlycurrent
sensorAnalogInputCount
OBJECT-TYPE
Number of analog input probes managed by the sensor device.
1.3.6.1.4.1.534.6.8.1.1.4.1.6Integer32read-onlycurrent
temperature
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.2
temperatureNotification
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.2.0
temperatureIdentificationTable
OBJECT-TYPE
A list of temperature probe measurements. the number of entries is given by the temperature count.
1.3.6.1.4.1.534.6.8.1.2.1not-accessiblecurrent
temperatureIdentificationEntry
OBJECT-TYPE
An entry for a temperature probe identification.
1.3.6.1.4.1.534.6.8.1.2.1.1not-accessiblecurrent
temperatureIndex
OBJECT-TYPE
A unique value for each temperature probe measurement. Its value ranges from 1 to sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.1.1.1Integer32 (1..2)accessible-for-notifycurrent
temperatureUuid
OBJECT-TYPE
A unique uuid value for each temperature.
1.3.6.1.4.1.534.6.8.1.2.1.1.2OCTET STRINGread-onlycurrent
temperatureConnectionType
OBJECT-TYPE
Probe connection type with the sensor that monitors it.
1.3.6.1.4.1.534.6.8.1.2.1.1.3ProbeConnectionTyperead-onlycurrent
temperatureConfigurationTable
OBJECT-TYPE
A list of temperature probe configuration. The number of entries is given by sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.2not-accessiblecurrent
temperatureConfigurationEntry
OBJECT-TYPE
An entry for a temperature probe configuration.
1.3.6.1.4.1.534.6.8.1.2.2.1not-accessiblecurrent
temperatureName
OBJECT-TYPE
The friendly name of the sensor temperature probe.
1.3.6.1.4.1.534.6.8.1.2.2.1.1OCTET STRING (SIZE(1..31))read-writecurrent
temperatureEnable
OBJECT-TYPE
Configure the temperature acquired or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.2.2.1.2EnableTyperead-writecurrent
temperatureOffset
OBJECT-TYPE
Configure the offset (Minus or Plus) to be added to the acquired value in order to correct the probe measurement error. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.3Integer32read-writecurrent
temperatureAlarmEnable
OBJECT-TYPE
Configure the temperature alarm depending on the thresholds evaluated or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.2.2.1.4EnableTyperead-writecurrent
temperatureThresholdLowWarning
OBJECT-TYPE
Low warning temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.5Integer32read-writecurrent
temperatureThresholdLowCritical
OBJECT-TYPE
Low critical temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.6Integer32read-writecurrent
temperatureThresholdHighWarning
OBJECT-TYPE
High warning temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.7Integer32read-writecurrent
temperatureThresholdHighCritical
OBJECT-TYPE
High critical temperature threshold. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.8Integer32read-writecurrent
temperatureThresholdHysteresis
OBJECT-TYPE
Temperature threshold hysteresis. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.2.1.9Integer32read-writecurrent
temperatureAlarmGracePeriod
OBJECT-TYPE
The grace period the alarm triggers after the acquired value crosses a trigger value (in seconds).
1.3.6.1.4.1.534.6.8.1.2.2.1.10Integer32 (1..60)read-writecurrent
temperatureMonitoringTable
OBJECT-TYPE
A list of temperature probe monitoring. The number of entries is given by sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.3not-accessiblecurrent
temperatureMonitoringEntry
OBJECT-TYPE
An entry for a temperature probe monitoring.
1.3.6.1.4.1.534.6.8.1.2.3.1not-accessiblecurrent
temperatureAlarm
OBJECT-TYPE
Alarm set according to the realtime measure compared to the thresholds.
1.3.6.1.4.1.534.6.8.1.2.3.1.1AlarmTyperead-onlycurrent
temperatureAlarmChangeSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the temperature alarm last change.
1.3.6.1.4.1.534.6.8.1.2.3.1.2UnixTimeStampread-onlycurrent
temperatureValue
OBJECT-TYPE
Realtime measured value after correction with the offset. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.3.1.3Integer32read-onlycurrent
temperatureCommunicationStatus
OBJECT-TYPE
Indicates how the temperature probe is communicating or not.
1.3.6.1.4.1.534.6.8.1.2.3.1.4CommunicationStatusread-onlycurrent
temperatureCommunicationStatusSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the temperature communication status last change.
1.3.6.1.4.1.534.6.8.1.2.3.1.5UnixTimeStampread-onlycurrent
temperatureMonitoringMinMaxTable
OBJECT-TYPE
A list of temperature probe monitoring Min and Max. The number of entries is given by sensorTemperatureCount.
1.3.6.1.4.1.534.6.8.1.2.4not-accessiblecurrent
temperatureMonitoringMinMaxEntry
OBJECT-TYPE
An entry for a temperature probe monitoring Min and Max.
1.3.6.1.4.1.534.6.8.1.2.4.1not-accessiblecurrent
temperatureMinValue
OBJECT-TYPE
Minimum value registered since the 1st connection of the sensor or the last reset. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.4.1.1Integer32read-onlycurrent
temperatureMinValueSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the temperature min value last change.
1.3.6.1.4.1.534.6.8.1.2.4.1.2UnixTimeStampread-onlycurrent
temperatureMaxValue
OBJECT-TYPE
Maximum value registered since the 1st connection of the sensor or the last reset. See temperatureUnit data for the units.
1.3.6.1.4.1.534.6.8.1.2.4.1.3Integer32read-onlycurrent
temperatureMaxValueSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the temperature max value last change.
1.3.6.1.4.1.534.6.8.1.2.4.1.4UnixTimeStampread-onlycurrent
temperatureResetMinMax
OBJECT-TYPE
Command that resets the min and max data with the current measure. 0:None, 1:Reset
1.3.6.1.4.1.534.6.8.1.2.4.1.5ResetCommandTyperead-writecurrent
temperatureUnit
OBJECT-TYPE
Temperature unit configuration. It is a global setting for all the v1 and v3 SNMP client. It does not involve the temperature unit of data stored and managed in the card. But it does configure the unit the temperatures data are red and written in this Mib. The possible values are tenthOfDegCelsius(0), tenthOfDegFarhenheit(1), tenthOfDegKelvin(2).
1.3.6.1.4.1.534.6.8.1.2.5TemperatureUnitTyperead-writecurrent
humidity
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.3
humidityNotification
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.3.0
humidityIdentificationTable
OBJECT-TYPE
A list of humidity probe measurements. the number of entries is given by the humidity count.
1.3.6.1.4.1.534.6.8.1.3.1not-accessiblecurrent
humidityIdentificationEntry
OBJECT-TYPE
An entry for a humidity probe identification.
1.3.6.1.4.1.534.6.8.1.3.1.1not-accessiblecurrent
humidityIndex
OBJECT-TYPE
A unique value for each humidity probe measurement. Its value ranges from 1 to sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.1.1.1Integer32 (1..2)accessible-for-notifycurrent
humidityUuid
OBJECT-TYPE
A unique uuid value for each humidity.
1.3.6.1.4.1.534.6.8.1.3.1.1.2OCTET STRINGread-onlycurrent
humidityConnectionType
OBJECT-TYPE
Probe connection type with the sensor that monitors it.
1.3.6.1.4.1.534.6.8.1.3.1.1.3ProbeConnectionTyperead-onlycurrent
humidityConfigurationTable
OBJECT-TYPE
A list of humidity probe configuration. The number of entries is given by sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.2not-accessiblecurrent
humidityConfigurationEntry
OBJECT-TYPE
An entry for a humidity probe configuration.
1.3.6.1.4.1.534.6.8.1.3.2.1not-accessiblecurrent
humidityName
OBJECT-TYPE
The friendly name of the sensor humidity probe.
1.3.6.1.4.1.534.6.8.1.3.2.1.1OCTET STRING (SIZE(1..31))read-writecurrent
humidityEnable
OBJECT-TYPE
Configure the humidity acquired or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.3.2.1.2EnableTyperead-writecurrent
humidityOffset
OBJECT-TYPE
Configure the offset (Minus or Plus) to be added to the acquired value in order to correct the probe measurement error. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.3Integer32read-writecurrent
humidityAlarmEnable
OBJECT-TYPE
Configure the humidity alarm depending on the thresholds evaluated or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.3.2.1.4EnableTyperead-writecurrent
humidityThresholdLowWarning
OBJECT-TYPE
Low warning humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.5Integer32read-writecurrent
humidityThresholdLowCritical
OBJECT-TYPE
Low critical humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.6Integer32read-writecurrent
humidityThresholdHighWarning
OBJECT-TYPE
High warning humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.7Integer32read-writecurrent
humidityThresholdHighCritical
OBJECT-TYPE
High critical humidity threshold in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.8Integer32read-writecurrent
humidityThresholdHysteresis
OBJECT-TYPE
humidity threshold hysteresis in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.2.1.9Integer32read-writecurrent
humidityAlarmGracePeriod
OBJECT-TYPE
The grace period the alarm triggers after the acquired value crosses a trigger value (in seconds).
1.3.6.1.4.1.534.6.8.1.3.2.1.10Integer32 (1..60)read-writecurrent
humidityMonitoringTable
OBJECT-TYPE
A list of humidity probe monitoring. The number of entries is given by sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.3not-accessiblecurrent
humidityMonitoringEntry
OBJECT-TYPE
An entry for a humidity probe monitoring.
1.3.6.1.4.1.534.6.8.1.3.3.1not-accessiblecurrent
humidityAlarm
OBJECT-TYPE
Alarm set according to the realtime measure compared to the thresholds.
1.3.6.1.4.1.534.6.8.1.3.3.1.1AlarmTyperead-onlycurrent
humidityAlarmChangeSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the humidity alarm last change.
1.3.6.1.4.1.534.6.8.1.3.3.1.2UnixTimeStampread-onlycurrent
humidityValue
OBJECT-TYPE
Realtime measured value after correction with the offset. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.3.1.3Integer32read-onlycurrent
humidityCommunicationStatus
OBJECT-TYPE
Indicates how the humidity probe is communicating or not.
1.3.6.1.4.1.534.6.8.1.3.3.1.4CommunicationStatusread-onlycurrent
humidityCommunicationStatusSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the humidity communication status last change.
1.3.6.1.4.1.534.6.8.1.3.3.1.5UnixTimeStampread-onlycurrent
humidityMonitoringMinMaxTable
OBJECT-TYPE
A list of humidity probe monitoring Min and Max. The number of entries is given by sensorhumidityCount.
1.3.6.1.4.1.534.6.8.1.3.4not-accessiblecurrent
humidityMonitoringMinMaxEntry
OBJECT-TYPE
An entry for a humidity probe monitoring Min and Max.
1.3.6.1.4.1.534.6.8.1.3.4.1not-accessiblecurrent
humidityMinValue
OBJECT-TYPE
Minimum value registered since the 1st connection of the sensor or the last reset. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.4.1.1Integer32read-onlycurrent
humidityMinValueSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the humidity min value last change.
1.3.6.1.4.1.534.6.8.1.3.4.1.2UnixTimeStampread-onlycurrent
humidityMaxValue
OBJECT-TYPE
Maximum value registered since the 1st connection of the sensor or the last reset. in tenth of % units.
1.3.6.1.4.1.534.6.8.1.3.4.1.3Integer32read-onlycurrent
humidityMaxValueSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the humidity max value last change.
1.3.6.1.4.1.534.6.8.1.3.4.1.4UnixTimeStampread-onlycurrent
humidityResetMinMax
OBJECT-TYPE
Command that resets the min and max data with the current measure. 0:None, 1:Reset
1.3.6.1.4.1.534.6.8.1.3.4.1.5ResetCommandTyperead-writecurrent
digitalInput
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.4
digitalInputNotification
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.4.0
digitalInputIdentificationTable
OBJECT-TYPE
A list of digital input probe measurements. The number of entries is given by sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.1not-accessiblecurrent
digitalInputIdentificationEntry
OBJECT-TYPE
An entry for a digital input identification.
1.3.6.1.4.1.534.6.8.1.4.1.1not-accessiblecurrent
digitalInputIndex
OBJECT-TYPE
A unique value for each digital input probe measurement. Its value ranges from 1 to sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.1.1.1Integer32 (1..2)accessible-for-notifycurrent
digitalInputUuid
OBJECT-TYPE
A unique uuid value for each digital Input.
1.3.6.1.4.1.534.6.8.1.4.1.1.2OCTET STRINGread-onlycurrent
digitalInputConnectionType
OBJECT-TYPE
Probe connection type with the sensor that monitors it.
1.3.6.1.4.1.534.6.8.1.4.1.1.3ProbeConnectionTyperead-onlycurrent
digitalInputConfigurationTable
OBJECT-TYPE
A list of digital input probe configuration. The number of entries is given by sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.2not-accessiblecurrent
digitalInputConfigurationEntry
OBJECT-TYPE
An entry for a digital input probe configuration.
1.3.6.1.4.1.534.6.8.1.4.2.1not-accessiblecurrent
digitalInputName
OBJECT-TYPE
The friendly name of the digital input probe.
1.3.6.1.4.1.534.6.8.1.4.2.1.1OCTET STRING (SIZE(1..31))read-writecurrent
digitalInputEnable
OBJECT-TYPE
Configure the digital input acquired or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.4.2.1.2EnableTyperead-writecurrent
digitalInputPolarity
OBJECT-TYPE
Configure the digitalInput polarity. 0 : Normally opened, 1 : Normally closed
1.3.6.1.4.1.534.6.8.1.4.2.1.3PolarityTyperead-writecurrent
digitalInputAlarmEnable
OBJECT-TYPE
Configure the digitalInput alarm depending on the polarity evaluated or not. 0:disabled, 1:enabled
1.3.6.1.4.1.534.6.8.1.4.2.1.4EnableTyperead-writecurrent
digitalInputAlarmSeverity
OBJECT-TYPE
Configure the alarm severity.
1.3.6.1.4.1.534.6.8.1.4.2.1.5AlarmSeverityTyperead-writecurrent
digitalInputAlarmGracePeriod
OBJECT-TYPE
The delay the alarm triggers when the state change event occurs (in seconds).
1.3.6.1.4.1.534.6.8.1.4.2.1.6Integer32 (1..60)read-writecurrent
digitalInputMonitoringTable
OBJECT-TYPE
A list of digital input probee monitoring. The number of entries is given by sensorDigitalInputCount.
1.3.6.1.4.1.534.6.8.1.4.3not-accessiblecurrent
digitalInputMonitoringEntry
OBJECT-TYPE
An entry for a digital Input probe.
1.3.6.1.4.1.534.6.8.1.4.3.1not-accessiblecurrent
digitalInputAlarm
OBJECT-TYPE
Alarm set according to the polarity and alarm severity configuration.
1.3.6.1.4.1.534.6.8.1.4.3.1.1AlarmLevelTyperead-onlycurrent
digitalInputAlarmChangeSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the digital input alarm last change.
1.3.6.1.4.1.534.6.8.1.4.3.1.2UnixTimeStampread-onlycurrent
digitalInputState
OBJECT-TYPE
Measure of the digital input after applying the polarity configured. 0 : Inactive, 1 : Active
1.3.6.1.4.1.534.6.8.1.4.3.1.3StateTyperead-onlycurrent
digitalInputStateSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the digital input state last change.
1.3.6.1.4.1.534.6.8.1.4.3.1.4UnixTimeStampread-onlycurrent
digitalInputCommunicationStatus
OBJECT-TYPE
Indicates how the digital input is communicating or not.
1.3.6.1.4.1.534.6.8.1.4.3.1.5CommunicationStatusread-onlycurrent
digitalInputCommunicationStatusSince
OBJECT-TYPE
UTC time in seconds since 1970/01/01 dating the digital input communication status last change.
1.3.6.1.4.1.534.6.8.1.4.3.1.6UnixTimeStampread-onlycurrent
conformance
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.10
objectGroups
OBJECT-IDENTITY
1.3.6.1.4.1.534.6.8.1.10.2

Notifications

NameOIDStatus
notifySensorCount
NOTIFICATION-TYPE
Sent whenever the sensor count changes after a discovery or removing from the UI.
1.3.6.1.4.1.534.6.8.1.1.0.1current
notifySensorStatus
NOTIFICATION-TYPE
Sent whenever the sensor status changes.
1.3.6.1.4.1.534.6.8.1.1.0.2current
notifyTemperatureAlarm
NOTIFICATION-TYPE
Sent whenever the temperature alarm changes.
1.3.6.1.4.1.534.6.8.1.2.0.1current
notifyTemperatureCommunicationStatus
NOTIFICATION-TYPE
Sent whenever the temperature communication status changes. Is not implemented when the probe is internal (see temperatureConnectionType).
1.3.6.1.4.1.534.6.8.1.2.0.2current
notifyHumidityAlarm
NOTIFICATION-TYPE
Sent whenever the humidity alarm changes.
1.3.6.1.4.1.534.6.8.1.3.0.1current
notifyHumidityCommunicationStatus
NOTIFICATION-TYPE
Sent whenever the humidity communication status changes. Is not implemented when the probe is internal (see humidityConnectionType).
1.3.6.1.4.1.534.6.8.1.3.0.2current
notifyDigitalInputAlarm
NOTIFICATION-TYPE
Sent whenever the digital input alarm changes.
1.3.6.1.4.1.534.6.8.1.4.0.1current
notifydigitalInputCommunicationStatus
NOTIFICATION-TYPE
Sent whenever the digital input communication status changes. Is not implemented when the probe is internal (see digitalInputConnectionType).
1.3.6.1.4.1.534.6.8.1.4.0.2current

Conformance

NameOIDStatus
eatonSensorCompliances
MODULE-COMPLIANCE
The requirements for conforming to the Sensor MIB.
1.3.6.1.4.1.534.6.8.1.10.1current
sensorRequiredGroup
OBJECT-GROUP
These objects are required to conform to this MIB.
1.3.6.1.4.1.534.6.8.1.10.2.1current
sensorOptionalGroup
OBJECT-GROUP
These objects in this MIB are optional.
1.3.6.1.4.1.534.6.8.1.10.2.2current
sensorNotifyGroup
NOTIFICATION-GROUP
These notifications will be supported depending on the features of the sensor.
1.3.6.1.4.1.534.6.8.1.10.2.3current