Dell-PHY-MIB
- Registered at
- 1.3.6.1.4.1.89.90
- Last updated
- 2002-09-30 00:24
- Organization
- Dell
- Revisions
- 2002-09-30 00:24, 2003-09-21 00:24
- Namespace
- dell
- Source file
Dell-PHY-MIB- Digest
sha256:a19c6a196685d7c6769fecc9c572c445b71f95d9895d4f3eaeebdc3e85ed2d6e
Description
The MIB module describes the private MIB for testing Layer1 interfaces supported by Dell's software and products.
Contact
www.dell.com
Imports
| From | Symbols |
|---|---|
| Dell-MIB | rnd |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
Dell-MIB Dell-PHY-MIB IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| RlPhyTestType TEXTUAL-CONVENTION A value indicating the test to perform. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rlPhyTest OBJECT-IDENTITY | 1.3.6.1.4.1.89.90.1 | |||
| rlPhyTestSetTable OBJECT-TYPE | 1.3.6.1.4.1.89.90.1.1 | not-accessible | current | |
| rlPhyTestSetEntry OBJECT-TYPE An entry containing objects for invoking tests on an interface. | 1.3.6.1.4.1.89.90.1.1.1 | not-accessible | current | |
| rlPhyTestSetType OBJECT-TYPE A control variable used to start operator initiated interface tests.1 indicates that no test has been initiated. Only operator initiated interface tests can be set to this variable. | 1.3.6.1.4.1.89.90.1.1.1.1 | RlPhyTestType | read-write | current |
| rlPhyTestGetTable OBJECT-TYPE | 1.3.6.1.4.1.89.90.1.2 | not-accessible | current | |
| rlPhyTestGetEntry OBJECT-TYPE An entry containing results of tests on an interface. | 1.3.6.1.4.1.89.90.1.2.1 | not-accessible | current | |
| rlPhyTestGetType OBJECT-TYPE A control variable used to, 1 to indicate that this test can be done on the specified port, 2 to initiate the test whenever the user wishes | 1.3.6.1.4.1.89.90.1.2.1.1 | RlPhyTestType | read-only | current |
| rlPhyTestGetStatus OBJECT-TYPE This object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the last reset. For non operator initiated tests the value is always none(1). Note that this facility provides no provision for saving the results of one test when starting another, as could be required if used by multiple managers concurrently. | 1.3.6.1.4.1.89.90.1.2.1.2 | INTEGER {none(1), success(2), inProgress(3), notSupported(4), unAbleToRun(5), aborted(6), failed(7)} | read-only | current |
| rlPhyTestGetResult OBJECT-TYPE This object holds the test result | 1.3.6.1.4.1.89.90.1.2.1.3 | INTEGER | read-only | current |
| rlPhyTestGetUnits OBJECT-TYPE The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7). | 1.3.6.1.4.1.89.90.1.2.1.4 | INTEGER {integer(1), boolean(2), downUP(3), reverseNormal(4), mdiMdix(5), meter(6), degree(7), microVolt(8), microOham(9), microAmper(10), microWatt(11), millisecond(12), alaskaPhyLength(13), alaskaPhyStatus(14), dbm(15), decidbm(16), milidbm(17), abcd(18), nanosecond(19)} | read-only | current |
| rlPhyTestGetAlarm OBJECT-TYPE This object hold the Alarm for this Entry. only Test that have can have alarms use this field, other holds the Value notRelevant(1) | 1.3.6.1.4.1.89.90.1.2.1.5 | INTEGER {notRelevant(1), noAlarmSet(2), lowWarning(3), highWarning(4), lowAlarm(5), highAlarm(6)} | read-only | current |
| rlPhyTestGetTimeStamp OBJECT-TYPE The time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31) | 1.3.6.1.4.1.89.90.1.2.1.6 | DisplayString (SIZE(1..32)) | read-only | current |