DataAire-dap4-al-MIB
- Last updated
- 2011-07-12 08:50
- Organization
- Data Aire
- Revisions
- 2011-07-12 08:50
- Namespace
- dataaire
- Source file
DataAire-dap4-al-MIB- Digest
sha256:cb5ea96c7e4be5b181daac58420534dc697b6cbdb6969bbda3ee5f2456a32df7
Description
This is the MIB module for the dap4_al device.
Contact
Data Aire 230 West Blueridge Ave Orange, CA Tel: 1-800-347-2473 E-mail: sales@dataaire.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-MIB | sysContact, sysLocation, sysName |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
DataAire-dap4-al-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| carel OBJECT-IDENTITY | 1.3.6.1.4.1.9839 | |||
| systm OBJECT-IDENTITY | 1.3.6.1.4.1.9839.1 | |||
| agentRelease OBJECT-TYPE Release of the Agent. | 1.3.6.1.4.1.9839.1.1 | Integer32 | read-only | current |
| agentCode OBJECT-TYPE Code of the Agent. 2=pCOWeb. | 1.3.6.1.4.1.9839.1.2 | Integer32 | read-only | current |
| instruments OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2 | |||
| pCOWebInfo OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2.0 | |||
| pCOStatusgroup OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2.0.10 | |||
| pCOId1_Status OBJECT-TYPE Status of pCOId1. 0=Offline, 1=Init, 2=Online | 1.3.6.1.4.1.9839.2.0.10.1 | Integer32 | read-only | current |
| pCOErrorsNumbergroup OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2.0.11 | |||
| pCOId1_ErrorsNumber OBJECT-TYPE Number of Communication Errors from pCOId1 to pCOWeb. | 1.3.6.1.4.1.9839.2.0.11.1 | Integer32 | read-only | current |
| digitalObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2.1.1 | |||
| dehum_on OBJECT-TYPE Dehumidify mode is running | 1.3.6.1.4.1.9839.2.1.1.1 | Integer32 (0..1) | read-only | current |
| hum_on OBJECT-TYPE Humidifier is running | 1.3.6.1.4.1.9839.2.1.1.2 | Integer32 (0..1) | read-only | current |
| engy_on OBJECT-TYPE Energy saver is running | 1.3.6.1.4.1.9839.2.1.1.3 | Integer32 (0..1) | read-only | current |
| cool_inhibit OBJECT-TYPE Cooling inhibit from Zone Master | 1.3.6.1.4.1.9839.2.1.1.4 | Integer32 (0..1) | read-only | current |
| heat_held OBJECT-TYPE Heat inhibited due to alarm condition | 1.3.6.1.4.1.9839.2.1.1.5 | Integer32 (0..1) | read-only | current |
| humidifier_inhibit OBJECT-TYPE Humidifier stopped due to alarm | 1.3.6.1.4.1.9839.2.1.1.6 | Integer32 (0..1) | read-only | current |
| dehum_inhibit OBJECT-TYPE Dehum is inhibited | 1.3.6.1.4.1.9839.2.1.1.7 | Integer32 (0..1) | read-only | current |
| rht_during_dehum OBJECT-TYPE reheat during dehum | 1.3.6.1.4.1.9839.2.1.1.8 | Integer32 (0..1) | read-only | current |
| floor_wtr_alm OBJECT-TYPE Water under floor alarm | 1.3.6.1.4.1.9839.2.1.1.9 | Integer32 (0..1) | read-only | current |
| air_flow_alm OBJECT-TYPE No air flow alarm | 1.3.6.1.4.1.9839.2.1.1.10 | Integer32 (0..1) | read-only | current |
| filter_alm OBJECT-TYPE Dirty filter from digital input | 1.3.6.1.4.1.9839.2.1.1.11 | Integer32 (0..1) | read-only | current |
| humidifier_alm OBJECT-TYPE Alarm from humidifier digital input | 1.3.6.1.4.1.9839.2.1.1.12 | Integer32 (0..1) | read-only | current |
| firestat_alm OBJECT-TYPE Temperature of return air above firestat alarm set point | 1.3.6.1.4.1.9839.2.1.1.13 | Integer32 (0..1) | read-only | current |
| shortcycle_alm OBJECT-TYPE One or more comps has short cycled | 1.3.6.1.4.1.9839.2.1.1.14 | Integer32 (0..1) | read-only | current |
| humidity_fail OBJECT-TYPE Sensor is out of range | 1.3.6.1.4.1.9839.2.1.1.15 | Integer32 (0..1) | read-only | current |
| ret_air_fail OBJECT-TYPE Sensor is out of range | 1.3.6.1.4.1.9839.2.1.1.16 | Integer32 (0..1) | read-only | current |
| maint_alm OBJECT-TYPE Maintenance Schedule Due alarm | 1.3.6.1.4.1.9839.2.1.1.17 | Integer32 (0..1) | read-only | current |
| c1_hp_alm OBJECT-TYPE High pressure alarm | 1.3.6.1.4.1.9839.2.1.1.18 | Integer32 (0..1) | read-only | current |
| c1_lp_alm OBJECT-TYPE Low pressure alarm | 1.3.6.1.4.1.9839.2.1.1.19 | Integer32 (0..1) | read-only | current |
| c2_hp_alm OBJECT-TYPE High pressure alarm | 1.3.6.1.4.1.9839.2.1.1.20 | Integer32 (0..1) | read-only | current |
| c2_lp_alm OBJECT-TYPE Low pressure alarm | 1.3.6.1.4.1.9839.2.1.1.21 | Integer32 (0..1) | read-only | current |
| smoke_alm OBJECT-TYPE Smoke detected from digital input | 1.3.6.1.4.1.9839.2.1.1.22 | Integer32 (0..1) | read-only | current |
| wtr_flow_alm OBJECT-TYPE No water flow alarm | 1.3.6.1.4.1.9839.2.1.1.23 | Integer32 (0..1) | read-only | current |
| disch_air_fail OBJECT-TYPE Sensor is out of range | 1.3.6.1.4.1.9839.2.1.1.24 | Integer32 (0..1) | read-only | current |
| ra_tmp_hi_alm OBJECT-TYPE Temperature of return air above alarm set point | 1.3.6.1.4.1.9839.2.1.1.25 | Integer32 (0..1) | read-only | current |
| ra_tmp_lo_alm OBJECT-TYPE Temperature of return air below alarm set point | 1.3.6.1.4.1.9839.2.1.1.26 | Integer32 (0..1) | read-only | current |
| hum_hi_alm OBJECT-TYPE Humidity above alarm set point | 1.3.6.1.4.1.9839.2.1.1.27 | Integer32 (0..1) | read-only | current |
| hum_lo_alm OBJECT-TYPE Humidity below alarm set point | 1.3.6.1.4.1.9839.2.1.1.28 | Integer32 (0..1) | read-only | current |
| fan_overload OBJECT-TYPE Fan overload | 1.3.6.1.4.1.9839.2.1.1.29 | Integer32 (0..1) | read-only | current |
| stdby_pump_on OBJECT-TYPE Standby pump on: Check primary pump -Optional alarm. Pump failure input signal required | 1.3.6.1.4.1.9839.2.1.1.30 | Integer32 (0..1) | read-only | current |
| cust_msg_sw1 OBJECT-TYPE Custom alarm #1 -Optional alarm. External alarm input required. Factory programmed custom message required | 1.3.6.1.4.1.9839.2.1.1.31 | Integer32 (0..1) | read-only | current |
| cust_msg_sw2 OBJECT-TYPE Custom alarm #2 -Optional alarm. External alarm input required. Factory programmed custom message required | 1.3.6.1.4.1.9839.2.1.1.32 | Integer32 (0..1) | read-only | current |
| cust_msg_sw3 OBJECT-TYPE Custom alarm #3 -Optional alarm. External alarm input required. Factory programmed custom message required | 1.3.6.1.4.1.9839.2.1.1.33 | Integer32 (0..1) | read-only | current |
| cust_msg_sw4 OBJECT-TYPE Custom alarm #4 -Optional alarm. External alarm input required. Factory programmed custom message required | 1.3.6.1.4.1.9839.2.1.1.34 | Integer32 (0..1) | read-only | current |
| humsw_inhibit OBJECT-TYPE Humidifier stopped due to custom alarm switch | 1.3.6.1.4.1.9839.2.1.1.35 | Integer32 (0..1) | read-only | current |
| heat_inhibit OBJECT-TYPE Heat inhibited due to custom switch alarm condition | 1.3.6.1.4.1.9839.2.1.1.36 | Integer32 (0..1) | read-only | current |
| rht_hum_inhibit OBJECT-TYPE Reheat and humidification inhibited from operation | 1.3.6.1.4.1.9839.2.1.1.37 | Integer32 (0..1) | read-only | current |
| disch_tmp_lo_alm OBJECT-TYPE Temperature of discharge air below alarm set point | 1.3.6.1.4.1.9839.2.1.1.38 | Integer32 (0..1) | read-only | current |
| override_alm OBJECT-TYPE Manual override: Check bypass switches - Standard alarm. Manual override switch is on | 1.3.6.1.4.1.9839.2.1.1.39 | Integer32 (0..1) | read-only | current |
| condensation_alm OBJECT-TYPE High condensation from digital input | 1.3.6.1.4.1.9839.2.1.1.40 | Integer32 (0..1) | read-only | current |
| unit_in_standby OBJECT-TYPE Unit in standby, all functions held off - Optional alarm. Control input signal required Factory setting required | 1.3.6.1.4.1.9839.2.1.1.41 | Integer32 (0..1) | read-only | current |
| cw_sns_fail OBJECT-TYPE Sensor is out of range | 1.3.6.1.4.1.9839.2.1.1.42 | Integer32 (0..1) | read-only | current |
| humsw_chk_cyl OBJECT-TYPE Humidifier stopped due to custom alarm switch | 1.3.6.1.4.1.9839.2.1.1.43 | Integer32 (0..1) | read-only | current |
| bms_cooling_inhibit OBJECT-TYPE Cooling operation inhibited by BMS | 1.3.6.1.4.1.9839.2.1.1.44 | Integer32 (0..1) | read-write | current |
| bms_heat_inhibit OBJECT-TYPE Heat inhibited due to bms | 1.3.6.1.4.1.9839.2.1.1.45 | Integer32 (0..1) | read-write | current |
| bms_humidifier_inhibit OBJECT-TYPE Humidifier operation inhibited by BMS | 1.3.6.1.4.1.9839.2.1.1.46 | Integer32 (0..1) | read-write | current |
| bms_dehum_inhibit OBJECT-TYPE Dehumidify mode inhibited by bms | 1.3.6.1.4.1.9839.2.1.1.47 | Integer32 (0..1) | read-write | current |
| fan_inhibit_bms OBJECT-TYPE Inhibit fan by bms | 1.3.6.1.4.1.9839.2.1.1.48 | Integer32 (0..1) | read-write | current |
| hum_expect OBJECT-TYPE Reduces control humidity cycling | 1.3.6.1.4.1.9839.2.1.1.49 | Integer32 (0..1) | read-only | current |
| usashr_f_c OBJECT-TYPE Temperature Mode 0=_C 1=_F | 1.3.6.1.4.1.9839.2.1.1.50 | Integer32 (0..1) | read-write | current |
| lead_comp OBJECT-TYPE Lead compressor select 0= C1, 1= C2 | 1.3.6.1.4.1.9839.2.1.1.52 | Integer32 (0..1) | read-only | current |
| wtrvlv_dir OBJECT-TYPE Water valve direct or reverse acting | 1.3.6.1.4.1.9839.2.1.1.53 | Integer32 (0..1) | read-only | current |
| ups_on_alm OBJECT-TYPE Alarm: UPS power on: Check main power -Optional alarm. External alarm input required | 1.3.6.1.4.1.9839.2.1.1.54 | Integer32 (0..1) | read-only | current |
| pwrup_alm OBJECT-TYPE Loss of power requires manual reset of alarm | 1.3.6.1.4.1.9839.2.1.1.55 | Integer32 (0..1) | read-only | current |
| seetag_cust_alm1 OBJECT-TYPE Local alarm #1: See tag inside door =Optional alarm. External alarm input required | 1.3.6.1.4.1.9839.2.1.1.56 | Integer32 (0..1) | read-only | current |
| seetag_cust_alm2 OBJECT-TYPE Local alarm #2: See tag inside door =Optional alarm. External alarm input required | 1.3.6.1.4.1.9839.2.1.1.57 | Integer32 (0..1) | read-only | current |
| seetag_cust_alm3 OBJECT-TYPE Local alarm #3: See tag inside door =Optional alarm. External alarm input required | 1.3.6.1.4.1.9839.2.1.1.58 | Integer32 (0..1) | read-only | current |
| seetag_cust_alm4 OBJECT-TYPE Local alarm #4: See tag inside door =Optional alarm. External alarm input required | 1.3.6.1.4.1.9839.2.1.1.59 | Integer32 (0..1) | read-only | current |
| shortcycle_alm_en OBJECT-TYPE Enable short cycle alarm of the compressors | 1.3.6.1.4.1.9839.2.1.1.60 | Integer32 (0..1) | read-only | current |
| superv_off OBJECT-TYPE Supervisor (BMS) On-Off. Show the state OFFbyBMS in main mask (1: Off; 0: On | 1.3.6.1.4.1.9839.2.1.1.61 | Integer32 (0..1) | read-only | current |
| BMS_heartbeat OBJECT-TYPE Bms heartbeat - pCO looks for update every 10 minutes | 1.3.6.1.4.1.9839.2.1.1.62 | Integer32 (0..1) | read-only | current |
| analogObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2.1.2 | |||
| ret_air_tmp OBJECT-TYPE Temperature of return air | 1.3.6.1.4.1.9839.2.1.2.1 | Integer32 (-32768..32767) | read-only | current |
| minmax_24hr_retair_maximum OBJECT-TYPE Maximum Return air temp in last 24hrs | 1.3.6.1.4.1.9839.2.1.2.2 | Integer32 (-32768..32767) | read-only | current |
| minmax_24hr_retair_minumum OBJECT-TYPE Minimum Return air temp in last 24hrs | 1.3.6.1.4.1.9839.2.1.2.3 | Integer32 (-32768..32767) | read-only | current |
| temp_setpoint OBJECT-TYPE Temperature setpoint | 1.3.6.1.4.1.9839.2.1.2.4 | Integer32 (-9999..9999) | read-write | current |
| temp_deadband OBJECT-TYPE Amount from setpoint before a comp is staged on | 1.3.6.1.4.1.9839.2.1.2.5 | Integer32 (0..99) | read-write | current |
| humidity_ain_offs OBJECT-TYPE Humidity Sensor Calibration | 1.3.6.1.4.1.9839.2.1.2.6 | Integer32 (-32768..32767) | read-only | current |
| return_ain_offs OBJECT-TYPE Return Temperature Sensor Calibration | 1.3.6.1.4.1.9839.2.1.2.7 | Integer32 (-32768..32767) | read-only | current |
| cw_tmp OBJECT-TYPE Temperature of chilled water | 1.3.6.1.4.1.9839.2.1.2.8 | Integer32 (-32768..32767) | read-only | current |
| disch_air_tmp OBJECT-TYPE Temperature of discharge air | 1.3.6.1.4.1.9839.2.1.2.9 | Integer32 (-32768..32767) | read-only | current |
| discharge_ain_offs OBJECT-TYPE Discharge Temperature Sensor Calibration - Optional discharge air temperature sensor required (B9) | 1.3.6.1.4.1.9839.2.1.2.10 | Integer32 (-32768..32767) | read-only | current |
| cw_ain_offs OBJECT-TYPE Chilled Water Temperature Sensor Calibration - Optional chilled water temperature sensor required (B10) | 1.3.6.1.4.1.9839.2.1.2.11 | Integer32 (-32768..32767) | read-only | current |
| engsaver_setpoint OBJECT-TYPE Temperature setpoint where chilled water will is requested | 1.3.6.1.4.1.9839.2.1.2.12 | Integer32 (-9999..9999) | read-write | current |
| opt1_analog OBJECT-TYPE Value of the analog input | 1.3.6.1.4.1.9839.2.1.2.13 | Integer32 (-32768..32767) | read-only | current |
| opt2_analog OBJECT-TYPE Value of the analog input | 1.3.6.1.4.1.9839.2.1.2.14 | Integer32 (-32768..32767) | read-only | current |
| opt3_analog OBJECT-TYPE Value of the analog input | 1.3.6.1.4.1.9839.2.1.2.15 | Integer32 (-32768..32767) | read-only | current |
| opt4_analog OBJECT-TYPE Value of the analog input | 1.3.6.1.4.1.9839.2.1.2.16 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_1_y1 OBJECT-TYPE Analog Sensor 1 Minimum Value | 1.3.6.1.4.1.9839.2.1.2.17 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_1_y2 OBJECT-TYPE Analog Sensor 1 Maximum Value | 1.3.6.1.4.1.9839.2.1.2.18 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_1_ain_offs OBJECT-TYPE Analog Sensor 1 Calibration | 1.3.6.1.4.1.9839.2.1.2.19 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_2_y1 OBJECT-TYPE Analog Sensor 2 Minimum Value | 1.3.6.1.4.1.9839.2.1.2.20 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_2_y2 OBJECT-TYPE Analog Sensor 2 Maximum Value | 1.3.6.1.4.1.9839.2.1.2.21 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_2_ain_offs OBJECT-TYPE Analog Sensor 2 Calibration | 1.3.6.1.4.1.9839.2.1.2.22 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_3_y1 OBJECT-TYPE Analog Sensor 3 Minimum Value | 1.3.6.1.4.1.9839.2.1.2.23 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_3_y2 OBJECT-TYPE Analog Sensor 3 Maximum Value | 1.3.6.1.4.1.9839.2.1.2.24 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_3_ain_offs OBJECT-TYPE Analog Sensor 3 Calibration | 1.3.6.1.4.1.9839.2.1.2.25 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_4_y1 OBJECT-TYPE Analog Sensor 4 Minimum Value | 1.3.6.1.4.1.9839.2.1.2.26 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_4_y2 OBJECT-TYPE Analog Sensor 4 Maximum Value | 1.3.6.1.4.1.9839.2.1.2.27 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_4_ain_offs OBJECT-TYPE Analog Sensor 4 Calibration | 1.3.6.1.4.1.9839.2.1.2.28 | Integer32 (-32768..32767) | read-only | current |
| integerObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9839.2.1.3 | |||
| disch_air_lo_sp OBJECT-TYPE Lower Limit alarm of discharge air temp | 1.3.6.1.4.1.9839.2.1.3.1 | Integer32 (-32767..32767) | read-write | current |
| humidity_dis OBJECT-TYPE Relative humidity displayed as xx% | 1.3.6.1.4.1.9839.2.1.3.2 | Integer32 (-999..999) | read-only | current |
| stages_on OBJECT-TYPE Cooling Stages On, DX only | 1.3.6.1.4.1.9839.2.1.3.3 | Integer32 (-32767..32767) | read-only | current |
| heaters_on OBJECT-TYPE Number of heat stages running | 1.3.6.1.4.1.9839.2.1.3.4 | Integer32 (-32768..32767) | read-only | current |
| minmax_24hr_hum_maximum OBJECT-TYPE Maximum humidity in last 24hrs | 1.3.6.1.4.1.9839.2.1.3.5 | Integer32 (-32768..32767) | read-only | current |
| minmax_24hr_hum_minumum OBJECT-TYPE Minimum humidity in last 24hrs | 1.3.6.1.4.1.9839.2.1.3.6 | Integer32 (-32768..32767) | read-only | current |
| comp_duty OBJECT-TYPE Cooling Utilization Over Last Hour -Percentage of cooling is used in the last hour of operation; this point applies to DX unit. | 1.3.6.1.4.1.9839.2.1.3.7 | Integer32 (0..999) | read-only | current |
| heat_duty OBJECT-TYPE Heating Utilization Over Last Hour -Percentage of heating is used in the last hour of operation | 1.3.6.1.4.1.9839.2.1.3.8 | Integer32 (0..999) | read-only | current |
| hum_duty OBJECT-TYPE Humidifier Utilization Over Last Hour -Percentage of humidifier is used in the last hour of operation | 1.3.6.1.4.1.9839.2.1.3.9 | Integer32 (0..999) | read-only | current |
| c1_hours_h OBJECT-TYPE Compressor 1 Runtime -This point applies to DX unit with one compressor -high | 1.3.6.1.4.1.9839.2.1.3.10 | Integer32 (-32768..32767) | read-only | current |
| c1_hours_l OBJECT-TYPE Compressor 1 Runtime -This point applies to DX unit with one compressor -low | 1.3.6.1.4.1.9839.2.1.3.11 | Integer32 (-32768..32767) | read-only | current |
| c2_hours_h OBJECT-TYPE Compressor 2 Runtime -This point applies to DX unit with dual compressor - high | 1.3.6.1.4.1.9839.2.1.3.12 | Integer32 (-32768..32767) | read-only | current |
| c2_hours_l OBJECT-TYPE Compressor 2 Runtime -This point applies to DX unit with dual compressor - low | 1.3.6.1.4.1.9839.2.1.3.13 | Integer32 (-32768..32767) | read-only | current |
| ht1_hours_h OBJECT-TYPE Heater 1 Runtime - high | 1.3.6.1.4.1.9839.2.1.3.14 | Integer32 (-32768..32767) | read-only | current |
| ht1_hours_l OBJECT-TYPE Heater 1 Runtime - low | 1.3.6.1.4.1.9839.2.1.3.15 | Integer32 (-32768..32767) | read-only | current |
| current_second OBJECT-TYPE Current second | 1.3.6.1.4.1.9839.2.1.3.16 | Integer32 (0..59) | read-only | current |
| current_minute OBJECT-TYPE Current minute | 1.3.6.1.4.1.9839.2.1.3.17 | Integer32 (0..59) | read-only | current |
| current_hour OBJECT-TYPE Current hour | 1.3.6.1.4.1.9839.2.1.3.18 | Integer32 (0..23) | read-only | current |
| current_day OBJECT-TYPE Current day | 1.3.6.1.4.1.9839.2.1.3.19 | Integer32 (1..31) | read-only | current |
| current_month OBJECT-TYPE Current month | 1.3.6.1.4.1.9839.2.1.3.20 | Integer32 (1..12) | read-only | current |
| current_year OBJECT-TYPE Current year | 1.3.6.1.4.1.9839.2.1.3.21 | Integer32 (0..99) | read-only | current |
| firestat_sp OBJECT-TYPE Alarm settting of return air temp to determine there is a fire | 1.3.6.1.4.1.9839.2.1.3.22 | Integer32 (0..999) | read-write | current |
| hum_hi_sp OBJECT-TYPE Humidity upper limit alarm | 1.3.6.1.4.1.9839.2.1.3.23 | Integer32 (0..99) | read-write | current |
| ret_air_hi_sp OBJECT-TYPE Upper limit alarm of return air temp | 1.3.6.1.4.1.9839.2.1.3.24 | Integer32 (-32768..32767) | read-write | current |
| hum_lo_sp OBJECT-TYPE Humidity lower limit alarm | 1.3.6.1.4.1.9839.2.1.3.25 | Integer32 (0..99) | read-write | current |
| ret_air_lo_sp OBJECT-TYPE Lower limit alarm of return air temp | 1.3.6.1.4.1.9839.2.1.3.26 | Integer32 (-32768..32767) | read-write | current |
| hum_deadband OBJECT-TYPE amount hum must change from setpoint before acting | 1.3.6.1.4.1.9839.2.1.3.27 | Integer32 (0..999) | read-write | current |
| hum_setpoint OBJECT-TYPE humidity setpoint | 1.3.6.1.4.1.9839.2.1.3.28 | Integer32 (0..999) | read-write | current |
| start_dly OBJECT-TYPE Time before the system starts up | 1.3.6.1.4.1.9839.2.1.3.29 | Integer32 (1..600) | read-write | current |
| alm1_del OBJECT-TYPE Optional Alarm 1 Delay | 1.3.6.1.4.1.9839.2.1.3.30 | Integer32 (0..32000) | read-only | current |
| alm2_del OBJECT-TYPE Optional Alarm 2 Delay | 1.3.6.1.4.1.9839.2.1.3.31 | Integer32 (0..32000) | read-only | current |
| alm3_del OBJECT-TYPE Optional Alarm 3 Delay | 1.3.6.1.4.1.9839.2.1.3.32 | Integer32 (0..32000) | read-only | current |
| alarm1_txt OBJECT-TYPE Message on optional alarm screen, some also add function | 1.3.6.1.4.1.9839.2.1.3.33 | Integer32 (0..16) | read-only | current |
| alarm2_txt OBJECT-TYPE Message on optional alarm screen, some also add function | 1.3.6.1.4.1.9839.2.1.3.34 | Integer32 (0..16) | read-only | current |
| alarm3_txt OBJECT-TYPE Message on optional alarm screen, some also add function | 1.3.6.1.4.1.9839.2.1.3.35 | Integer32 (0..16) | read-only | current |
| alarm4_txt OBJECT-TYPE Message on optional alarm screen, some also add function | 1.3.6.1.4.1.9839.2.1.3.36 | Integer32 (0..16) | read-only | current |
| comp_sel OBJECT-TYPE Comps 0=none, 1=one, 2=one+UL, 3=two, 4=two+UL, 5=Four/two circuit | 1.3.6.1.4.1.9839.2.1.3.37 | Integer32 (0..5) | read-only | current |
| dehum_mode OBJECT-TYPE 0=none, 1= comp limited, 2=twocomp limited, 3= comp unlimited, 4=twocomp unlimited | 1.3.6.1.4.1.9839.2.1.3.38 | Integer32 (0..4) | read-only | current |
| reheat_sel OBJECT-TYPE Number of heat stages | 1.3.6.1.4.1.9839.2.1.3.39 | Integer32 (0..3) | read-only | current |
| hum_sel OBJECT-TYPE 0=none, 1=comp mod, 2=comp non, 3= comf mod, 4= conf non mod | 1.3.6.1.4.1.9839.2.1.3.40 | Integer32 (0..4) | read-only | current |
| alm_contact_msg OBJECT-TYPE Text displayed on all alarm screens | 1.3.6.1.4.1.9839.2.1.3.41 | Integer32 (0..4) | read-only | current |
| powerup_sel OBJECT-TYPE 0= start wo/alarm, 1= start w/alarm, 2= requires reset of alarm | 1.3.6.1.4.1.9839.2.1.3.42 | Integer32 (0..2) | read-only | current |
| buzzer_select OBJECT-TYPE 0=None, 1=short beeps, 2=long beep, 3=Constant | 1.3.6.1.4.1.9839.2.1.3.43 | Integer32 (0..3) | read-only | current |
| cw_disp OBJECT-TYPE % of 10volts of analog output #1 | 1.3.6.1.4.1.9839.2.1.3.44 | Integer32 (0..999) | read-only | current |
| wtrvlv_duty OBJECT-TYPE Chilled Water Utilization Over Last Hour - This applies to Chilled water or Energy saver units. | 1.3.6.1.4.1.9839.2.1.3.45 | Integer32 (0..999) | read-only | current |
| hum_hours_h OBJECT-TYPE Humidifier Runtime - high | 1.3.6.1.4.1.9839.2.1.3.46 | Integer32 (-32768..32767) | read-only | current |
| hum_hours_l OBJECT-TYPE Humidifier Runtime - low | 1.3.6.1.4.1.9839.2.1.3.47 | Integer32 (-32768..32767) | read-only | current |
| blower_hours_h OBJECT-TYPE Blower Runtime - high | 1.3.6.1.4.1.9839.2.1.3.48 | Integer32 (-32768..32767) | read-only | current |
| blower_hours_l OBJECT-TYPE Blower Runtime - low | 1.3.6.1.4.1.9839.2.1.3.49 | Integer32 (-32768..32767) | read-only | current |
| alm4_del OBJECT-TYPE Optional Alarm 4 Delay | 1.3.6.1.4.1.9839.2.1.3.50 | Integer32 (0..32000) | read-only | current |
| assist_sel OBJECT-TYPE 0= no comp assist, 1=one comp assist, 2= two comp assist, 3... 4... | 1.3.6.1.4.1.9839.2.1.3.51 | Integer32 (0..5) | read-only | current |
| wtrvlv_sel OBJECT-TYPE Water valve type 0=none, 1=chill, 2=Engy, 3=Aux chill, 4=Disc Reg | 1.3.6.1.4.1.9839.2.1.3.52 | Integer32 (0..4) | read-only | current |
| wtrvlv_volts_sel OBJECT-TYPE Water valve voltage 0= 0-10, 1=2-10, 2=7-10, 3=6-9, 4=4-7 | 1.3.6.1.4.1.9839.2.1.3.53 | Integer32 (0..4) | read-only | current |
| hum_volts OBJECT-TYPE % of 10volts of analog output #2 | 1.3.6.1.4.1.9839.2.1.3.54 | Integer32 (0..999) | read-only | current |
| dehum_hours_h OBJECT-TYPE Dehumidifier Runtime - High | 1.3.6.1.4.1.9839.2.1.3.55 | Integer32 (-32768..32767) | read-only | current |
| dehum_hours_l OBJECT-TYPE Dehumidifier Runtime - Low | 1.3.6.1.4.1.9839.2.1.3.56 | Integer32 (-32768..32767) | read-only | current |
| autoflush_dly OBJECT-TYPE Time between drain cycles 0=12hr, 1=24hr, 2=48hr, 3=96hr, 4=None | 1.3.6.1.4.1.9839.2.1.3.58 | Integer32 (0..99) | read-only | current |
| y4_out OBJECT-TYPE Value sent to optional analog output#1 | 1.3.6.1.4.1.9839.2.1.3.59 | Integer32 (-32768..32767) | read-only | current |
| y5_out OBJECT-TYPE Value sent to optional analog output#2 | 1.3.6.1.4.1.9839.2.1.3.60 | Integer32 (-32768..32767) | read-only | current |
| air_flow OBJECT-TYPE Current Fan Airflow - Based on calculated Pressure Diff formula | 1.3.6.1.4.1.9839.2.1.3.61 | Integer32 (-32768..32767) | read-only | current |
| opt_snsr1_name OBJECT-TYPE Name of the sensor | 1.3.6.1.4.1.9839.2.1.3.62 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_1_ain_type OBJECT-TYPE Analog Sensor 1 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170} | 1.3.6.1.4.1.9839.2.1.3.63 | Integer32 (0..9) | read-only | current |
| opt_snsr2_name OBJECT-TYPE Name of the sensor | 1.3.6.1.4.1.9839.2.1.3.64 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_2_ain_type OBJECT-TYPE Analog Sensor 2 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170} | 1.3.6.1.4.1.9839.2.1.3.65 | Integer32 (0..9) | read-only | current |
| opt_snsr3_name OBJECT-TYPE Name of the sensor | 1.3.6.1.4.1.9839.2.1.3.66 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_3_ain_type OBJECT-TYPE Analog Sensor 3 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170} | 1.3.6.1.4.1.9839.2.1.3.67 | Integer32 (0..9) | read-only | current |
| opt_snsr4_name OBJECT-TYPE Name of the sensor | 1.3.6.1.4.1.9839.2.1.3.68 | Integer32 (-32768..32767) | read-only | current |
| opt_sns_4_ain_type OBJECT-TYPE Analog Sensor 4 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170} | 1.3.6.1.4.1.9839.2.1.3.69 | Integer32 (0..9) | read-only | current |
| cw_fan_speed_bms OBJECT-TYPE CW Fan speed (%) sent via BMS | 1.3.6.1.4.1.9839.2.1.3.70 | Integer32 (0..100) | read-write | current |
| dx_fan_speed_bms OBJECT-TYPE DX Fan speed (%) sent via BMS | 1.3.6.1.4.1.9839.2.1.3.71 | Integer32 (0..100) | read-write | current |
| fan_speed_max OBJECT-TYPE Maximum Fan speed (% of output) modulation. | 1.3.6.1.4.1.9839.2.1.3.72 | Integer32 (70..100) | read-write | current |
| fan_speed_min OBJECT-TYPE Minimum Fan speed (% of output) modulation from pressure. | 1.3.6.1.4.1.9839.2.1.3.73 | Integer32 (40..100) | read-write | current |
| fan_pr_sp OBJECT-TYPE Fan pressure setpoint (0.01 inches of water) | 1.3.6.1.4.1.9839.2.1.3.74 | Integer32 (0..1001) | read-write | current |
| fan_pr_band OBJECT-TYPE Fan pressure band (0.01 inches of water) | 1.3.6.1.4.1.9839.2.1.3.75 | Integer32 (1..100) | read-write | current |
| fan_af_max OBJECT-TYPE Maximum air flow limit of setpoint from BMS or valve modulation. | 1.3.6.1.4.1.9839.2.1.3.76 | Integer32 (0..32000) | read-write | current |
| fan_af_min OBJECT-TYPE Minimum air flow limit of setpoint from BMS or valve modulation. | 1.3.6.1.4.1.9839.2.1.3.77 | Integer32 (0..32000) | read-write | current |
| fan_kfactor OBJECT-TYPE Fan K Factor | 1.3.6.1.4.1.9839.2.1.3.78 | Integer32 (100..500) | read-write | current |
| num_fans OBJECT-TYPE Number of fans installed in this unit | 1.3.6.1.4.1.9839.2.1.3.79 | Integer32 (1..3) | read-write | current |
| ht2_hours_h OBJECT-TYPE Heater 2 Runtime - high | 1.3.6.1.4.1.9839.2.1.3.81 | Integer32 (-32768..32767) | read-only | current |
| ht2_hours_l OBJECT-TYPE Heater 2 Runtime - low | 1.3.6.1.4.1.9839.2.1.3.82 | Integer32 (-32768..32767) | read-only | current |
| ht3_hours_h OBJECT-TYPE Heater 3 Runtime - high | 1.3.6.1.4.1.9839.2.1.3.83 | Integer32 (-32768..32767) | read-only | current |
| ht3_hours_l OBJECT-TYPE Heater 3 Runtime - low | 1.3.6.1.4.1.9839.2.1.3.84 | Integer32 (-32768..32767) | read-only | current |
| engy_hours_h OBJECT-TYPE Energy Saver Runtime - This optional point applies to energy saver units only -high | 1.3.6.1.4.1.9839.2.1.3.85 | Integer32 (-32768..32767) | read-only | current |
| engy_hours_l OBJECT-TYPE Energy Saver Runtime - This optional point applies to energy saver units only - low | 1.3.6.1.4.1.9839.2.1.3.86 | Integer32 (-32768..32767) | read-only | current |
| cw_hours_h OBJECT-TYPE Chilled Water Runtime - This applies to chilled water units only - high | 1.3.6.1.4.1.9839.2.1.3.87 | Integer32 (-32768..32767) | read-only | current |
| cw_hours_l OBJECT-TYPE Chilled Water Runtime - This applies to chilled water units only - low | 1.3.6.1.4.1.9839.2.1.3.88 | Integer32 (-32768..32767) | read-only | current |
| c3_hours_h OBJECT-TYPE Compressor 3 Runtime - This applies when unit has four stages tandem compressors - high | 1.3.6.1.4.1.9839.2.1.3.89 | Integer32 (-32768..32767) | read-only | current |
| c3_hours_l OBJECT-TYPE Compressor 3 Runtime - This applies when unit has four stages tandem compressors - low | 1.3.6.1.4.1.9839.2.1.3.90 | Integer32 (-32768..32767) | read-only | current |
| c4_hours_l OBJECT-TYPE Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - high | 1.3.6.1.4.1.9839.2.1.3.91 | Integer32 (-32768..32767) | read-only | current |
| c4_hours_h OBJECT-TYPE Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - low | 1.3.6.1.4.1.9839.2.1.3.92 | Integer32 (-32768..32767) | read-only | current |
| cond_hours_h OBJECT-TYPE Condenser Runtime - high | 1.3.6.1.4.1.9839.2.1.3.93 | Integer32 (-32768..32767) | read-only | current |
| cond_hours_l OBJECT-TYPE Condenser Runtime - low | 1.3.6.1.4.1.9839.2.1.3.94 | Integer32 (-32768..32767) | read-only | current |
| dx_fan_speed OBJECT-TYPE Fan speed (% of output) when compressor cooling. | 1.3.6.1.4.1.9839.2.1.3.95 | Integer32 (60..100) | read-only | current |
| cw_fan_speed OBJECT-TYPE Fan speed (% of output) when cold water cooling. | 1.3.6.1.4.1.9839.2.1.3.96 | Integer32 (60..100) | read-only | current |
| fan_af_dx_sp OBJECT-TYPE Fan air flow setpoint for DX unit (cfm) | 1.3.6.1.4.1.9839.2.1.3.97 | Integer32 (0..32000) | read-only | current |
| fan_af_cw_sp OBJECT-TYPE Fan air flow setpoint for CW unit (cfm) | 1.3.6.1.4.1.9839.2.1.3.98 | Integer32 (0..32000) | read-only | current |
| zm_airflow_sp OBJECT-TYPE Zone Airflow Setpoint kcfm | 1.3.6.1.4.1.9839.2.1.3.99 | Integer32 (-32768..32767) | read-write | current |