The Broadcom Private MIB for DNOS Box Services Feature.

Imports

FromSymbols
DELL-REF-MIBdnOS
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DELL-REF-MIB
DNOS-BOXSERVICES-PRIVATE-MIB
Dell-Vendor-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
BoxsTemperatureStatus
TEXTUAL-CONVENTION
The temperature state
current

Objects

NameOIDSyntaxAccessStatus
fastPathBoxServicesTraps
OBJECT-IDENTITY
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0
boxServicesGroup
OBJECT-IDENTITY
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1
boxServicesNormalTempRangeMin
OBJECT-TYPE
Lower boundary of normal temperature range.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.1Integer32 (-100..100)read-writecurrent
boxServicesNormalTempRangeMax
OBJECT-TYPE
Upper boundary of normal temperature range.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.2Integer32 (-100..100)read-writecurrent
boxServicesTemperatureTrapEnable
OBJECT-TYPE
Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.3INTEGER {enable(1), disable(2)}read-writecurrent
boxServicesPSMStateTrapEnable
OBJECT-TYPE
Enable or disable Power Supply Module state change trap.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.4INTEGER {enable(1), disable(2)}read-writecurrent
boxServicesFanStateTrapEnable
OBJECT-TYPE
Enable or disable Fan state change trap.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.5INTEGER {enable(1), disable(2)}read-writecurrent
boxServicesFansTable
OBJECT-TYPE
Fan
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6not-accessiblecurrent
boxServicesFansEntry
OBJECT-TYPE
Box Services Fan Entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1not-accessiblecurrent
boxServicesFansIndex
OBJECT-TYPE
Unique index of fan table entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.1Integer32 (0..2147483647)read-onlycurrent
boxServicesFanItemType
OBJECT-TYPE
The type of fan
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.2INTEGER {fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6)}read-onlycurrent
boxServicesFanItemState
OBJECT-TYPE
The status of fan. nopower(4) - This state means the fan is present but no AC is connected.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.3INTEGER {notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7)}read-onlycurrent
boxServicesFanSpeed
OBJECT-TYPE
The speed of fan
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.4Integer32read-onlycurrent
boxServicesFanDutyLevel
OBJECT-TYPE
The duty level of fan, in percents
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.5Integer32read-onlycurrent
boxServicesPowSuppliesTable
OBJECT-TYPE
Power supply
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7not-accessiblecurrent
boxServicesPowSuppliesEntry
OBJECT-TYPE
Box Services Power Supply Entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1not-accessiblecurrent
boxServicesPowSupplyIndex
OBJECT-TYPE
Unique index of power supply table entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.1Integer32 (0..2147483647)read-onlycurrent
boxServicesPowSupplyItemType
OBJECT-TYPE
The type of power supply
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.2INTEGER {fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6)}read-onlycurrent
boxServicesPowSupplyItemState
OBJECT-TYPE
The status of power supply. nopower(4) - This state means the power supply is present but no AC is connected. incompatible(5) - This state is possible on boards capable of pluggable Power supplies
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.3INTEGER {notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7)}read-onlycurrent
boxServicesTempSensorsTable
OBJECT-TYPE
Temperature sensor
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8not-accessiblecurrent
boxServicesTempSensorsEntry
OBJECT-TYPE
Box Services Temperature Sensor Entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1not-accessiblecurrent
boxServicesUnitIndex
OBJECT-TYPE
Unit index for an entry in the Box Services Temperature Sensor Table
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.1Unsigned32read-onlycurrent
boxServicesTempSensorIndex
OBJECT-TYPE
Unique index of temperature sensor table entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.2Unsigned32read-onlycurrent
boxServicesTempSensorType
OBJECT-TYPE
The type of temperature sensor
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.3INTEGER {fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6)}read-onlycurrent
boxServicesTempSensorState
OBJECT-TYPE
The state of temperature sensor
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.4INTEGER {normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6)}read-onlyobsolete
boxServicesTempSensorTemperature
OBJECT-TYPE
The temperature value reported by sensor
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5Integer32read-onlycurrent
boxsUnitPwrUsageHistoryTable
OBJECT-TYPE
A table providing configuration and status of Power Usage History feature
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9not-accessiblecurrent
boxsUnitPwrUsageHistoryEntry
OBJECT-TYPE
Power Usage History Table for a Unit.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1not-accessiblecurrent
boxsPwrUsageHistoryUnitIndex
OBJECT-TYPE
This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the unitIndex for the corresponding unit entry in the Power Usage History Table.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.1INTEGER (1..8)not-accessiblecurrent
boxsPwrUsageHistoryUnitSampleIndex
OBJECT-TYPE
This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the sampleIndex for the corresponding sample entry in the Power Usage History Table.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.2INTEGER (1..2147483647)not-accessiblecurrent
boxsPwrUsageHistoryUnitSampleTime
OBJECT-TYPE
Time at which the Sample was collected.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3DisplayString (SIZE(1..32))read-onlycurrent
boxsPwrUsageHistoryUnitPowerConsumption
OBJECT-TYPE
Power Consumption (mWatts) at the time of collecting the given sample.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.4INTEGERread-onlycurrent
boxsPwrUsageHistoryStackPowerConsumption
OBJECT-TYPE
Power Consumption (mWatts) per Stack at the time of collecting the given sample.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.5INTEGERread-onlycurrent
boxsPwrUsageHistoryUnitSampleInterval
OBJECT-TYPE
Interval at which power consumption data needs to be collected.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.10INTEGER (30..86400)read-writecurrent
boxsPwrUsageHistoryUnitMaxSamples
OBJECT-TYPE
Maximum number of samples to keep.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.11INTEGER (1..168)read-writecurrent
boxServicesThermalShutdownSensor
OBJECT-TYPE
The number of the sensor which initiated thermal shutdown.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.13Unsigned32accessible-for-notifycurrent
boxServicesThermalShutdownTemperature
OBJECT-TYPE
The temperature of the sensor which initiated thermal shutdown.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.14Unsigned32accessible-for-notifycurrent
boxServicesTempUnitTable
OBJECT-TYPE
Temperature status table
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15not-accessiblecurrent
boxServicesTempUnitEntry
OBJECT-TYPE
Box Services Temperature Unit Entry
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1not-accessiblecurrent
boxServicesTempUnitIndex
OBJECT-TYPE
Unit index for an entry in the Box Services Temperature Unit Table
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.1Unsigned32not-accessiblecurrent
boxServicesTempUnitState
OBJECT-TYPE
The temperature state of the unit
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.2BoxsTemperatureStatusread-onlycurrent
boxServicesTempUnitTemperature
OBJECT-TYPE
The highest temperature currently reported by any sensor on the unit
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.3Integer32read-onlycurrent
boxServicesNotificationsGroup
OBJECT-IDENTITY
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2
boxsItemStateChangeEvent
OBJECT-TYPE
This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.1INTEGER {insertion(1), removal(2), becomeoperational(3), failure(4), losepower(5)}accessible-for-notifycurrent
boxsTemperatureChangeEvent
OBJECT-TYPE
This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold)
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.2INTEGER {abovethreshold(1), belowthreshold(2), withinnormalrange(3)}accessible-for-notifycurrent
boxsTemperatureStatusCurrentEvent
OBJECT-TYPE
This event describes the current status of a switch.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.3BoxsTemperatureStatusaccessible-for-notifycurrent
boxsTemperatureStatusPreviousEvent
OBJECT-TYPE
This event describes the previous status of a switch.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.2.4BoxsTemperatureStatusaccessible-for-notifycurrent
boxsLocatorLedConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4
boxsLocatorLedUnit
OBJECT-TYPE
Spesifies unit number where Locator LED should blink on. This is write-only value. It always returns '0' on request if the Locator Led feature is supported.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4.1INTEGERread-writecurrent
boxsLocatorLedTime
OBJECT-TYPE
Indicates time period in seconds for Locator LED blinking. The range is from 20 to 3600 seconds. The dafault value is 20 seconds. This is write-only value. It always returns '0' on request if the Locator Led feature is supported.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4.2INTEGERread-writecurrent
boxsLocatorLedEnable
OBJECT-TYPE
Starts the Locator LED blinking. If boxsLocatorLedUnit has not been set current(manager) unit number will be used. If boxsLocatorLedTime has not been set default value(20 seconds) will be used. This is write-only value. It always returns '0' on request if the Locator Led feature is supported.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.4.3INTEGER {disable(0), enable(1)}read-writecurrent

Notifications

NameOIDStatus
boxsFanStateChange
NOTIFICATION-TYPE
Trap is sent when fan state change happens.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.1current
boxsPowSupplyStateChange
NOTIFICATION-TYPE
Trap is sent when power supply state change happens.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.2current
boxsTemperatureChange
NOTIFICATION-TYPE
Trap is sent when temperature is changing and crossing any of the thresholds
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.3obsolete
boxsThermalShutdown
NOTIFICATION-TYPE
Trap is sent when thermal shutdown is initiated.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.4current
boxsTemperatureStateChange
NOTIFICATION-TYPE
Trap is sent when the system temperature crosses a threshold. To avoid rapid flapping between states, a hysteresis may be applied.
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.0.5current