MIBs Depot

DLINKSW-SAFEGUARD-ENGINE-MIB

Registered at
1.3.6.1.4.1.171.14.19.1.1
Last updated
2012-06-27 00:00
Organization
D-Link Corp.
Revisions
2012-06-27 00:00
Namespace
dlink
Source file
DLINKSW-SAFEGUARD-ENGINE-MIB
Digest
sha256:360bbe479a6459e67dea6d1d3d3a9b0084d2f5f2340e9ca0f50afe37478239bb

Description

The MIB module for managing Safeguard engine.

Contact

D-Link Corporation Postal: No. 289, Sinhu 3rd Rd., Neihu District, Taipei City 114, Taiwan, R.O.C Tel: +886-2-66000123 E-mail: tsd@dlink.com.tw

Imports

FromSymbols
DLINKSW-CPU-PROTECT-MIBdCpuProtectMIBObjects
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DLINK-ID-REC-MIB
DLINKSW-CPU-PROTECT-MIB
DLINKSW-SAFEGUARD-ENGINE-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
dSafeguardEngineMIBNotif
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.19.1.1.0
dSafeguardEngineMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.19.1.1.1
dSafeguardEngineState
OBJECT-TYPE
This object is used to configure and show the state of Safeguard Engine.
1.3.6.1.4.1.171.14.19.1.1.1.1INTEGER {enable(1), disable(2)}read-writecurrent
dSafeguardEngineRiseThresh
OBJECT-TYPE
This object is used to configure and show the rising threshold of Safeguard Engine.
1.3.6.1.4.1.171.14.19.1.1.1.2INTEGER (20..100)read-writecurrent
dSafeguardEngineFallThresh
OBJECT-TYPE
This object is used to configure and show the falling threshold of Safeguard Engine.
1.3.6.1.4.1.171.14.19.1.1.1.3INTEGER (20..100)read-writecurrent
dSafeguardEngineCurrentMode
OBJECT-TYPE
This object show the current mode of Safeguard Engine.
1.3.6.1.4.1.171.14.19.1.1.1.4INTEGER {normal(1), exhausted(2)}read-onlycurrent
dSafeguardEngineNotifEnable
OBJECT-TYPE
This object specifies whether the system sends notifications to the NMS.
1.3.6.1.4.1.171.14.19.1.1.1.5TruthValueread-writecurrent
dSafeguardEngineMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.19.1.1.2
dSafeguardEngineCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.19.1.1.2.1
dSafeguardEngineGroups
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.19.1.1.2.2

Notifications

NameOIDStatus
dSafeguardChgToExhausted
NOTIFICATION-TYPE
This trap indicates System change operation mode from normal to exhausted.
1.3.6.1.4.1.171.14.19.1.1.0.1current
dSafeguardChgToNormal
NOTIFICATION-TYPE
This trap indicates System change operation mode from exhausted to normal.
1.3.6.1.4.1.171.14.19.1.1.0.2current

Conformance

NameOIDStatus
dSafeguardEngineCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement the DLINKSW-SAFEGUARD-ENGINE-MIB.
1.3.6.1.4.1.171.14.19.1.1.2.1.1current
dSafeguardEngineGroup
OBJECT-GROUP
A collection of objects providing the configuration or inforamtion about Safeguard Engine.
1.3.6.1.4.1.171.14.19.1.1.2.2.1current
dSafeguardEngNotifEnableGroup
OBJECT-GROUP
A collection of object(s) that provides control over Safeguard Engine related notification(s).
1.3.6.1.4.1.171.14.19.1.1.2.2.2current
dSafeguardEngineNotifGroup
NOTIFICATION-GROUP
A collection of notifications providing information about the System mode change of Safeguard Engine.
1.3.6.1.4.1.171.14.19.1.1.2.2.3current