sha256:6bf7b540a123f22875344496c7fd4d61de567cfa45190c2fafa5e444f2b8194a

Description

This MIB module provides essential information about the system and defines the managed objects that support the monitoring of alarms generated by physical entities, including temperature sensors, fans and power supplies.

Contact

D-Link Corporation Postal: No. 289, Sinhu 3rd Rd., Neihu District, Taipei City 114, Taiwan, R.O.C Tel: +886-2-66000123 E-mail: tsd@dlink.com.tw

Imports

FromSymbols
DLINK-ID-REC-MIBdlinkIndustrialCommon
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DLINK-ID-REC-MIB
DLINKSW-ENTITY-EXT-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
dEntityExtNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.0
dEntityExtObjects
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.1
dEntityExtEnvObjects
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.1.1
dEntityExtEnvTempTable
OBJECT-TYPE
The table consists of a list of temperature information.
1.3.6.1.4.1.171.14.5.1.1.1not-accessiblecurrent
dEntityExtEnvTempEntry
OBJECT-TYPE
An entry represents the temperature status of a testpoint.
1.3.6.1.4.1.171.14.5.1.1.1.1not-accessiblecurrent
dEntityExtEnvTempUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID at which the testpoint is located.
1.3.6.1.4.1.171.14.5.1.1.1.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtEnvTempIndex
OBJECT-TYPE
This object is used to uniquely identify the testpoint within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning.
1.3.6.1.4.1.171.14.5.1.1.1.1.2Integer32 (1..2147483647)not-accessiblecurrent
dEntityExtEnvTempDescr
OBJECT-TYPE
This object provides human-sensible identification for the testpoint. e.g. 'Inlet', 'Center', 'Outlet'.
1.3.6.1.4.1.171.14.5.1.1.1.1.3DisplayString (SIZE(0..32))read-onlycurrent
dEntityExtEnvTempCurrent
OBJECT-TYPE
This object indicates the current measurement of the testpoint.
1.3.6.1.4.1.171.14.5.1.1.1.1.4Integer32read-onlycurrent
dEntityExtEnvTempThresholdLow
OBJECT-TYPE
The object indicates the minimum acceptable reading of the testpoint in degrees Celsius.
1.3.6.1.4.1.171.14.5.1.1.1.1.5Integer32read-writecurrent
dEntityExtEnvTempThresholdHigh
OBJECT-TYPE
The object indicates the maximum acceptable reading of the testpoint in degrees Celsius.
1.3.6.1.4.1.171.14.5.1.1.1.1.6Integer32read-writecurrent
dEntityExtEnvTempStatus
OBJECT-TYPE
The object indicates the current temperature is over the thresholds or not. 'abnormal' indicates the temperature is over the thresholds. 'ok' indicates the temperature is not over the thresholds.
1.3.6.1.4.1.171.14.5.1.1.1.1.7INTEGER {ok(1), abnormal(2)}read-onlycurrent
dEntityExtEnvFanTable
OBJECT-TYPE
The table is used to display the status of fans.
1.3.6.1.4.1.171.14.5.1.1.2not-accessiblecurrent
dEntityExtEnvFanEntry
OBJECT-TYPE
An entry represents a fan status.
1.3.6.1.4.1.171.14.5.1.1.2.1not-accessiblecurrent
dEntityExtEnvFanUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID at which the fan is located.
1.3.6.1.4.1.171.14.5.1.1.2.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtEnvFanIndex
OBJECT-TYPE
This object is used to uniquely identify the fan within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning.
1.3.6.1.4.1.171.14.5.1.1.2.1.2Integer32 (1..2147483647)not-accessiblecurrent
dEntityExtEnvFanDescr
OBJECT-TYPE
This object provides human-sensible identification for the fan. e.g. 'Left 1' for the first fan on the left.
1.3.6.1.4.1.171.14.5.1.1.2.1.3DisplayString (SIZE(0..32))read-onlycurrent
dEntityExtEnvFanStatus
OBJECT-TYPE
This object indicates the fan status.
1.3.6.1.4.1.171.14.5.1.1.2.1.4INTEGER {ok(1), fault(2)}read-onlycurrent
dEntityExtEnvPowerTable
OBJECT-TYPE
The table is used to display the status of the power modules.
1.3.6.1.4.1.171.14.5.1.1.3not-accessiblecurrent
dEntityExtEnvPowerEntry
OBJECT-TYPE
An entry contains the information of a power module.
1.3.6.1.4.1.171.14.5.1.1.3.1not-accessiblecurrent
dEntityExtEnvPowerUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID at which the power module is located.
1.3.6.1.4.1.171.14.5.1.1.3.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtEnvPowerIndex
OBJECT-TYPE
This object indicates the ID of the power module. This object is used to uniquely identify the power module. This index is for SNMP purposes only, and has no intrinsic meaning.
1.3.6.1.4.1.171.14.5.1.1.3.1.2Unsigned32 (1..2147483647)not-accessiblecurrent
dEntityExtEnvPowerDescr
OBJECT-TYPE
This object provides human-sensible information for the power module. e.g. '#1 (internal)', '#2 (external)'.
1.3.6.1.4.1.171.14.5.1.1.3.1.3DisplayString (SIZE(0..32))read-onlycurrent
dEntityExtEnvPowerUsedPower
OBJECT-TYPE
This object indicates the amount of the power that has been allocated.
1.3.6.1.4.1.171.14.5.1.1.3.1.4Unsigned32read-onlycurrent
dEntityExtEnvPowerMaxPower
OBJECT-TYPE
This object indicates maximum power which the power module can supply.
1.3.6.1.4.1.171.14.5.1.1.3.1.5Unsigned32read-onlycurrent
dEntityExtEnvPowerStatus
OBJECT-TYPE
This object indicates the status of the power.
1.3.6.1.4.1.171.14.5.1.1.3.1.6INTEGER {inOperation(1), failed(2), empty(3)}read-onlycurrent
dEntityExtEnvAirFlowTable
OBJECT-TYPE
The table is used to display the status of the air flow function.
1.3.6.1.4.1.171.14.5.1.1.4not-accessiblecurrent
dEntityExtEnvAirFlowEntry
OBJECT-TYPE
An entry contains the information of the air flow function.
1.3.6.1.4.1.171.14.5.1.1.4.1not-accessiblecurrent
dEntityExtEnvAirFlowUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID at which the air flow module is located.
1.3.6.1.4.1.171.14.5.1.1.4.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtEnvAirFlowStatus
OBJECT-TYPE
This object indicates the status of the air flow. The fans' air flow direction must match the system's air flow direction to form an integrated air flow. For example: In DXS-3600, the normal fans' air flow direction must match the power fan's air flow direction. The power fan blow the cold air from outside to inside, all the normal fans must blow the hot air from inside to outside. Or the power fan blow the hot air from inside to outside, all the normal fans must blow the cold air from outside to inside. If one or more fans' air flow direction does not match the system's air flow direction, it will form an abnormal air flow. Then this log message will be triggered. ok(1) : A recover event indicates the air flow back to normal. abnormal(2): An alarm event indicates the air flow detects abnormal.
1.3.6.1.4.1.171.14.5.1.1.4.1.2INTEGER {ok(1), abnormal(2)}read-onlycurrent
dEntityExtEnvTrap
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.1.2
dEntityExtEnvNotifyEnable
OBJECT-TYPE
This object indicates whether a specified notification is enabled or not. If a bit corresponding to a notification is set to 1, then the specified notification can be generated. fan(0) - fan trap state for warning fan event (fan failed or fan recover). power(1) - power trap state for warning power event (power failure or power recovery). temperature(2) - temperature trap state for warning temperature event (temperature exceeds the thresholds or temperature recover).
1.3.6.1.4.1.171.14.5.1.2.1Bits {fan(0), power(1), temperature(2)}read-writecurrent
dEntityExtUnitTable
OBJECT-TYPE
The table is used to display information of units.
1.3.6.1.4.1.171.14.5.1.3not-accessiblecurrent
dEntityExtUnitEntry
OBJECT-TYPE
An entry contains essential information of a unit.
1.3.6.1.4.1.171.14.5.1.3.1not-accessiblecurrent
dEntityExtUnitIndex
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.3.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtUnitStatus
OBJECT-TYPE
This object represents the status of the unit: ok(1) - This indicates the unit is okay. failed(2) - This indicates the unit fails due to some reason. empty(3) - This indicates that the unit is provisioned but currently not installed.
1.3.6.1.4.1.171.14.5.1.3.1.2INTEGER {ok(1), failed(2), empty(3)}read-onlycurrent
dEntityExtUnitUpTime
OBJECT-TYPE
This object provides the up time in units of seconds for the unit since it was last re-initialized.
1.3.6.1.4.1.171.14.5.1.3.1.3Unsigned32read-onlycurrent
dEntityExtMemoryUtilTable
OBJECT-TYPE
The table is used to display memory utilization information.
1.3.6.1.4.1.171.14.5.1.4not-accessiblecurrent
dEntityExtMemoryUtilEntry
OBJECT-TYPE
An entry contains memory utilization information.
1.3.6.1.4.1.171.14.5.1.4.1not-accessiblecurrent
dEntityExtMemUtilUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.4.1.1Integer32 (1..65535)not-accessiblecurrent
dEntityExtMemUtilType
OBJECT-TYPE
The object indicates the memory type of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.2INTEGER {dram(1), flash(2), nvram(3)}not-accessiblecurrent
dEntityExtMemUtilTotal
OBJECT-TYPE
This object indicates the total memory size of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.3Unsigned32read-onlycurrent
dEntityExtMemUtilUsed
OBJECT-TYPE
This object indicates the used memory size of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.4Unsigned32read-onlycurrent
dEntityExtMemUtilFree
OBJECT-TYPE
This object indicates the free memory size of the entry.
1.3.6.1.4.1.171.14.5.1.4.1.5Unsigned32read-onlycurrent
dEntityExtCpuUtilTable
OBJECT-TYPE
The table is used to display CPU utilization information.
1.3.6.1.4.1.171.14.5.1.7not-accessiblecurrent
dEntityExtCpuUtilEntry
OBJECT-TYPE
An entry contains CPU information.
1.3.6.1.4.1.171.14.5.1.7.1not-accessiblecurrent
dEntityExtCpuUtilUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.7.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtCpuUtilCpuID
OBJECT-TYPE
This object is used to uniquely identify the CPU within a unit (multiprocessing system).
1.3.6.1.4.1.171.14.5.1.7.1.2Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtCpuUtilFiveSeconds
OBJECT-TYPE
This objects indicates the overall CPU busy percentage in the last 5 second period. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.14.5.1.7.1.3Unsigned32read-onlycurrent
dEntityExtCpuUtilOneMinute
OBJECT-TYPE
This objects indicates the overall CPU busy percentage in the last 1 minute period. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.14.5.1.7.1.4Unsigned32read-onlycurrent
dEntityExtCpuUtilFiveMinutes
OBJECT-TYPE
This objects indicates the overall CPU busy percentage in the last 5 minute period. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.14.5.1.7.1.5Unsigned32read-onlycurrent
dEntityExtVersionTable
OBJECT-TYPE
The table is used to display version information of units.
1.3.6.1.4.1.171.14.5.1.8not-accessiblecurrent
dEntityExtVersionEntry
OBJECT-TYPE
An entry contains version information of a unit.
1.3.6.1.4.1.171.14.5.1.8.1not-accessiblecurrent
dEntityExtVersionUnitId
OBJECT-TYPE
This object indicates the unit (stacking device) or slot (chassis device) ID.
1.3.6.1.4.1.171.14.5.1.8.1.1Unsigned32 (1..65535)not-accessiblecurrent
dEntityExtVersionBootloader
OBJECT-TYPE
This object indicates the bootloader version of the unit.
1.3.6.1.4.1.171.14.5.1.8.1.2DisplayString (SIZE(0..32))read-onlycurrent
dEntityExtVersionRuntime
OBJECT-TYPE
This object indicates the firmware version of one unit.
1.3.6.1.4.1.171.14.5.1.8.1.3DisplayString (SIZE(0..32))read-onlycurrent
dEntityExtConformance
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.2
dEntityExtMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.2.1
dEntityExtMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.5.2.2

Notifications

NameOIDStatus
dEntityExtFanStatusChg
NOTIFICATION-TYPE
This trap indicates a fan fails (dEntityExtEnvFanStatus is 'fault') or recovers (dEntityExtEnvFanStatus is 'ok').
1.3.6.1.4.1.171.14.5.0.1current
dEntityExtThermalStatusChg
NOTIFICATION-TYPE
This trap indicates a thermal alarms (dEntityExtEnvTempStatus is 'abnormal') or recovers (dEntityExtEnvTempStatus is 'ok').
1.3.6.1.4.1.171.14.5.0.2current
dEntityExtPowerStatusChg
NOTIFICATION-TYPE
This trap indicates a power module fails, recovers or is removed.
1.3.6.1.4.1.171.14.5.0.3current
dEntityExtAirFlowChg
NOTIFICATION-TYPE
This trap is triggered when the air flow status is changed from 'ok' to 'abnormal' and vice versa. dEntityExtEnvAirFlowStatus indicates the current (new) fan air flow state.
1.3.6.1.4.1.171.14.5.0.4current
dEntityExtFactoryResetButton
NOTIFICATION-TYPE
This trap is triggered when the factory reset button was pressed.
1.3.6.1.4.1.171.14.5.0.5current

Conformance

NameOIDStatus
dEntityExtCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement the DLINKSW-ENTITY-EXT-MIB.
1.3.6.1.4.1.171.14.5.2.1.1current
dEntityExtTempGroup
OBJECT-GROUP
A collection of objects provides information of the system temperature.
1.3.6.1.4.1.171.14.5.2.2.1current
dEntityExtFanGroup
OBJECT-GROUP
A collection of objects providing informations of fans.
1.3.6.1.4.1.171.14.5.2.2.2current
dEntityExtPowerGroup
OBJECT-GROUP
A collection of objects providing information of power modules.
1.3.6.1.4.1.171.14.5.2.2.3current
dEntityExtSystemInfoGroup
OBJECT-GROUP
A collection of objects provides information of the system temperature.
1.3.6.1.4.1.171.14.5.2.2.4current
dEntityExtGenericNotifInfoGroup
OBJECT-GROUP
A collection of objects provides generic information for binding variables of notification.
1.3.6.1.4.1.171.14.5.2.2.5current
dEntityExtFanNotifGroup
NOTIFICATION-GROUP
A collection of notifications for indicating the status change of fans.
1.3.6.1.4.1.171.14.5.2.2.6current
dEntityExtThermalNotifGroup
NOTIFICATION-GROUP
A collection of notifications for indicating the status change of thermals.
1.3.6.1.4.1.171.14.5.2.2.7current
dEntityExtPowerNotifGroup
NOTIFICATION-GROUP
A collection of notifications for indicating the status change of power module.
1.3.6.1.4.1.171.14.5.2.2.8current
dEntityExtAirFlowNotifGroup
NOTIFICATION-GROUP
A collection of notifications for indicating the status change of the air flow.
1.3.6.1.4.1.171.14.5.2.2.9current
dEntityExtFactoryResetButtonNotifGroup
NOTIFICATION-GROUP
A collection of notifications for indicating the factory reset button.
1.3.6.1.4.1.171.14.5.2.2.10current