MIBs Depot

DLINKSW-BPDU-PROTECTION-MIB

Registered at
1.3.6.1.4.1.171.14.47
Last updated
2013-02-19 00:00
Organization
D-Link Corp.
Revisions
2013-02-19 00:00
Namespace
dlink
Source file
DLINKSW-BPDU-PROTECTION-MIB
Digest
sha256:14482f014b39017b65e4e0c914d78c9cd2f079bc27447a9e0c12c1d27a879d77

Description

This MIB module defines objects for BPDU Protection.

Contact

D-Link Corporation Postal: No. 289, Sinhu 3rd Rd., Neihu District, Taipei City 114, Taiwan, R.O.C Tel: +886-2-66000123 E-mail: tsd@dlink.com.tw

Imports

FromSymbols
DLINK-ID-REC-MIBdlinkIndustrialCommon
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DLINK-ID-REC-MIB
DLINKSW-BPDU-PROTECTION-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
dBpduProtectionNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.47.0
dBpduProtectionObjects
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.47.1
dBpduProtectionGlobalEnabled
OBJECT-TYPE
This object indicates the global BPDU Protection state. 'true' - The BPDU Protection is enabled globally. 'false' - The lBPDU Protection is disabled globally.
1.3.6.1.4.1.171.14.47.1.1TruthValueread-writecurrent
dBpduProtectionNotifyEnabled
OBJECT-TYPE
This object indicates whether sending SNMP notifications for BPDU Protection.
1.3.6.1.4.1.171.14.47.1.2TruthValueread-writecurrent
dBpduProtectionIfTable
OBJECT-TYPE
This table consists of a list of interface-specific BPDU Protection information entries.
1.3.6.1.4.1.171.14.47.1.3not-accessiblecurrent
dBpduProtectionIfEntry
OBJECT-TYPE
An entry indicates the state and attack status of BPDU Protection on an interface.
1.3.6.1.4.1.171.14.47.1.3.1not-accessiblecurrent
dBpduProtectionIfCfgMode
OBJECT-TYPE
This object indicates the operational mode of BPDU Protection on the interface. disabled(1) - The BPDU Protection is disabled. drop(2) - Drop all received BPDU packets when the interface enters the attacked state. block(3) - Drop all packets (include BPDU and normal packets) when the interface enters the attacked state. shutdown(4) - Shut down the interface when the interface enters he attacked state.
1.3.6.1.4.1.171.14.47.1.3.1.1INTEGER {disabled(1), drop(2), block(3), shutdown(4)}read-writecurrent
dBpduProtectionIfAttackStatus
OBJECT-TYPE
This object indicates the status of BPDU Protection on an interface. normal(1) - The interface is under normal status. underAttack(2) - The inter is under attack status.
1.3.6.1.4.1.171.14.47.1.3.1.2INTEGER {normal(1), underAttack(2)}read-onlycurrent
dBpduProtectionConformance
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.47.2
dBpduProtectionMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.47.2.1
dBpduProtectionMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.171.14.47.2.2

Notifications

NameOIDStatus
dBpduProtectionAttackOccur
NOTIFICATION-TYPE
This trap is sent when the BPDU attack happened on an interface.
1.3.6.1.4.1.171.14.47.0.1current
dBpduProtectionAttackRecover
NOTIFICATION-TYPE
This trap is sent when the BPDU attack recovered on an interface.
1.3.6.1.4.1.171.14.47.0.2current

Conformance

NameOIDStatus
dBpduProtectionMIBCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement the DLINKSW-BPDU-PROTECTION-MIB.
1.3.6.1.4.1.171.14.47.2.1.1current
dBpduProtectionCfgGroup
OBJECT-GROUP
A collection of objects providing management of the BPDU Protection feature.
1.3.6.1.4.1.171.14.47.2.2.1current
dBpduProtectionIfGroup
OBJECT-GROUP
A collection of objects providing management and information for BPDU Protection a per-interface basis.
1.3.6.1.4.1.171.14.47.2.2.2current
dBpduProtectionNotifyGroup
NOTIFICATION-GROUP
A collection of notifications for BPDU Protection.
1.3.6.1.4.1.171.14.47.2.2.3current