MIBs Depot

DLINK-TIME-MIB

Last updated
1902-02-14 00:00
Organization
DLink Corporation
Namespace
dlink
Source file
DLINK-TIME-MIB
Digest
sha256:9df00d80f5a55401816f6a30709d3ec36b8ada84dfb029dd1c78aeedd624a396

Description

DLink equipments absolute time.

Imports

FromSymbols
DLINK-ID-REC-MIBdlink-common-mgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIIpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DLINK-ID-REC-MIB
DLINK-TIME-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
swTimeCapacity
OBJECT-TYPE
A string of 8 bits, corresponding to indicates the time capacity supported in the system. If sntp bit(1) is 1 , indicate the SNTP is supported else if sntp bit is 0, the SNTP is not supported and the subtree swSNTP will not supported also. If summerTime bit(2) is 1 ,indicate the SummerTime is supported else if sntp bit is 0, the SummerTime is not supported and the subtree swSummerTime will not supported also. If realTimeClock(3) bit is 1 , indicate the real time clock is supported else if the bit is 0, the real time clock is not supported . Default systemTime bit(0) is 1; indicate the system time is supported.
1.3.6.1.4.1.171.12.10.1Bits {systemTime(0), sntp(1), summerTime(2), realTimeClock(3)}read-onlycurrent
swCurrentClock
OBJECT-TYPE
The current local date and time for the system. Setting this object is equivalent to setting an automated clock and calendar. The value of the object will track the date and time from the value set. Note that due to hardware limitations some systems may not be able to preserve such meaning across reboots of the system, as indicated by swDlinkClockLostOnReboot. A constant value of all zeros and length 8 indicates the system is not aware of the present date and time. This object may be read-only on some systems.
1.3.6.1.4.1.171.12.10.2DateAndTimeread-writecurrent
swClockLostOnReboot
OBJECT-TYPE
Indication of whether the system can preserve knowledge of current date and time across a system reboot. A value of 'true' indicates the clock must be reset from some external source each time the system reboots. A value of 'false' indicates the system has the ability to keep time across reboots.
1.3.6.1.4.1.171.12.10.3TruthValueread-onlycurrent
swSystemTime
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.10.10
swSystemCurrentTime
OBJECT-TYPE
the mandatory network time was got from the SNTP server
1.3.6.1.4.1.171.12.10.10.1DisplayString (SIZE(0..32))read-onlycurrent
swSystemUpTime
OBJECT-TYPE
The time (in second) since the network management portion of the system was last re-initialized. It is the same as sysUptime.
1.3.6.1.4.1.171.12.10.10.2DisplayString (SIZE(0..32))read-onlycurrent
swSystemBootTime
OBJECT-TYPE
The boot time of the switch is equal to subtract systemUpTime from swSNTPCurrentTime
1.3.6.1.4.1.171.12.10.10.3DisplayString (SIZE(0..32))read-onlycurrent
swSystemTimeZone
OBJECT-TYPE
Local time offset in minutes from GMT.
1.3.6.1.4.1.171.12.10.10.4INTEGER (-779..839)read-writecurrent
swSNTP
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.10.11
swSNTPState
OBJECT-TYPE
This object enable/disable the SNTP function.
1.3.6.1.4.1.171.12.10.11.1INTEGER {other(1), disabled(2), enabled(3)}read-writecurrent
swSNTPTimeSource
OBJECT-TYPE
the SNTP server status for time source changing
1.3.6.1.4.1.171.12.10.11.2INTEGER {system(0), server1(1), server2(2)}read-onlycurrent
swSNTPServer1IPAddr
OBJECT-TYPE
Configure the SNTP server #1 IP address
1.3.6.1.4.1.171.12.10.11.3IpAddressread-writecurrent
swSNTPServer2IPAddr
OBJECT-TYPE
Configure the SNTP server #2 IP address
1.3.6.1.4.1.171.12.10.11.4IpAddressread-writecurrent
swSNTPPollInterval
OBJECT-TYPE
Update time in seconds from SNTP server.
1.3.6.1.4.1.171.12.10.11.5INTEGER (30..99999)read-writecurrent
swSummerTime
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.10.12
swSummerTimeStatus
OBJECT-TYPE
An indication of whether the summertime feature is disabled or enabled in reprating or annual mode on this device. When this object is set to repeating,then the summertime frature is enabled and swSummerTimeOffset,swSummerTimeRepeatingStart ,swSummerTimeRepeatingEnd objects are work effectively . When this object is set to annual, then the summertime frature is enabled and swSummerTimeOffset, swAnnualSummerTimeStart, swAnnualSummerTimeEnd objects are work effectively.
1.3.6.1.4.1.171.12.10.12.1INTEGER {disable(0), repeating(1), annual(2)}read-writecurrent
swSummerTimeOffset
OBJECT-TYPE
The value of this object indicates number of minutes to add or to subtract during summertime. This object is not instantiated when swSummerTimeStatus object is set to disable.
1.3.6.1.4.1.171.12.10.12.2INTEGER (0..1440)read-writecurrent
swRepeatSummerTimeStart
OBJECT-TYPE
Indicates summertime starts at this time every year. octets contents range 1 week 1..4,00 last = 00 2-3 day 1..7 where sunday = 1 saturday = 7 4 month 1..12 where january = 1 december = 12 5 hour 0..23 6 min 0..59 For example, the first Monday in Feb at 13:30pm should be given as 01 00 02 02 0e 1e For the last Tuesday in dec at 1:20am should be given as 00 00 03 0c 01 14 This object is not instantiated when swSummerTimeStatus object is not set to repeating.
1.3.6.1.4.1.171.12.10.12.3OCTET STRING (SIZE(6))read-writecurrent
swRepeatSummerTimeEnd
OBJECT-TYPE
Indicates summertime ends at this time every year. octets contents range 1 week 1..5,ff where ff = last 2-3 day 1..7 where sunday = 1 saturday = 7 4 month 1..12 where january = 1 december = 12 5 hour 0..23 6 min 0..59 For example, the third friday in February at 3:30am should be given as 03 00 06 02 03 1e For the first Tuesday in May at 1:20am should be given as 01 00 03 05 01 14 This object is not instantiated when swSummerTimeStatus object is not set to repeating.
1.3.6.1.4.1.171.12.10.12.4OCTET STRING (SIZE(6))read-writecurrent
swAnnualSummerTimeStart
OBJECT-TYPE
Indicates summertime starts at this time every year. octets contents range 1 monthDay 1..31, 2 month 1..12 where january = 1 december = 12 3 hour 0..23 4 min 0..59 For example, the first Feb at 13:30pm should be given as 01 02 0e 1e For the tenth dec at 1:20am should be given as ff 00 03 0c 01 14 This object is not instantiated when swSummerTimeStatus object is not set to annual.
1.3.6.1.4.1.171.12.10.12.5OCTET STRING (SIZE(4))read-writecurrent
swAnnualSummerTimeEnd
OBJECT-TYPE
Indicates summertime ends at this time every year. octets contents range 1 monthDay 1..31, 2 month 1..12 where january = 1 december = 12 3 hour 0..23 4 min 0..59 For example, the third February at 3:30am should be given as 03 02 03 1e For the first May at 1:20am should be given as 01 05 01 14 This object is not instantiated when swSummerTimeStatus object is not set to annual.
1.3.6.1.4.1.171.12.10.12.6OCTET STRING (SIZE(4))read-writecurrent
swTimeNotifPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.10.13