MIBs Depot

DLINK-EQUIPMENT-MIB

Last updated
1902-02-14 00:00
Organization
DLink Corporation
Namespace
dlink
Source file
DLINK-EQUIPMENT-MIB
Digest
sha256:5c272236e074443b5913672abacdf290ff7c33321e8019b338164429b01ff202

Description

DLink equipments MIB .

Imports

FromSymbols
DLINK-ID-REC-MIBAgentNotifyLevel, dlink-common-mgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DLINK-EQUIPMENT-MIB
DLINK-ID-REC-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
MacAddress
type

Objects

NameOIDSyntaxAccessStatus
swDlinkEquipmentMib
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.1
swDlinkEquipmentCapacity
OBJECT-TYPE
Indicates the equipment capacity supported in the system .
1.3.6.1.4.1.171.12.11.1.1Bits {fanCapable(0), redundantPowerCapable(1), tempteratureDetection(2), stackingCapable(3), chassisCapable(4)}read-onlycurrent
swPowerTable
OBJECT-TYPE
A list of temperature.
1.3.6.1.4.1.171.12.11.1.6not-accessiblecurrent
swPowerEntry
OBJECT-TYPE
A entry of Power information.
1.3.6.1.4.1.171.12.11.1.6.1not-accessiblecurrent
swPowerUnitIndex
OBJECT-TYPE
Indicates ID of the unit in the System
1.3.6.1.4.1.171.12.11.1.6.1.1INTEGER (0..65535)read-onlycurrent
swPowerID
OBJECT-TYPE
Indicates ID of the power 1 : main power 2 : redundant power .
1.3.6.1.4.1.171.12.11.1.6.1.2INTEGER (0..65535)read-onlycurrent
swPowerStatus
OBJECT-TYPE
Indicates status of the power
1.3.6.1.4.1.171.12.11.1.6.1.3INTEGER {other(0), lowVoltage(1), overCurrent(2), working(3), fail(4), connect(5), disconnect(6)}read-onlycurrent
swUnitMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.1.9
swUnitStackingVersion
OBJECT-TYPE
This object indicates the version of this stacking system .
1.3.6.1.4.1.171.12.11.1.9.1INTEGER (0..65535)read-onlycurrent
swUnitMaxSupportedUnits
OBJECT-TYPE
Maximum number of units are supported in the system.
1.3.6.1.4.1.171.12.11.1.9.2INTEGER (0..65535)read-onlycurrent
swUnitNumOfUnit
OBJECT-TYPE
The current number of units.
1.3.6.1.4.1.171.12.11.1.9.3INTEGER (0..65535)read-onlycurrent
swUnitMgmtTable
OBJECT-TYPE
This table contains the unit information.
1.3.6.1.4.1.171.12.11.1.9.4not-accessiblecurrent
swUnitMgmtEntry
OBJECT-TYPE
A list of management information for each unit in the system.
1.3.6.1.4.1.171.12.11.1.9.4.1not-accessiblecurrent
swUnitMgmtId
OBJECT-TYPE
This object indicates the specific entry in the stacking/chassis table.
1.3.6.1.4.1.171.12.11.1.9.4.1.1INTEGER (1..15)read-onlycurrent
swUnitMgmtMacAddr
OBJECT-TYPE
The Mac address of this unit.
1.3.6.1.4.1.171.12.11.1.9.4.1.2MacAddressread-onlycurrent
swUnitMgmtStartPort
OBJECT-TYPE
This object indicates the start port of this unit.
1.3.6.1.4.1.171.12.11.1.9.4.1.3INTEGER (1..65535)read-onlycurrent
swUnitMgmtPortRange
OBJECT-TYPE
This object indicates the total ports of this unit.
1.3.6.1.4.1.171.12.11.1.9.4.1.4INTEGER (0..65535)read-onlycurrent
swUnitMgmtFrontPanelLedStatus
OBJECT-TYPE
This object is a set of system LED indications. The first three octets is defined as system LED. The first LED is power LED. The second LED is console LED. The third LED is RPS (Redundancy Power Supply) LED. The other octets following the second octets are the logical port LED (following dot1dBasePort ordering). One byte is presented to one port and this byte is presentd to the Link/Activity LED. Link/Activity LED : The most significant bit is used for blink/solid: 8 = The LED blinks. The second significant bit is used for link status: 1 = link fail. 2 = link pass. The four remaining bits are currently unused and must be 0.
1.3.6.1.4.1.171.12.11.1.9.4.1.5OCTET STRING (SIZE(0..255))read-onlycurrent
swUnitMgmtCtrlMode
OBJECT-TYPE
This object indicates the stack mode that user configed for this unit. The object only can be configed when the device is stand alone. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. auto(2) - the system will auto assign this stack role of this unit to be stand-alone(3), master(4), or slave(5). stand-alone(3) - the unit is forced to stand alone. master(4) - the unit is forced to master. If this unit is seleted to be master, it can modify the configuration of the stacking system. slave(5) - the unit is forced to slave. If this unit is seleted to be slave, it only can view the configuration of the stacking system.
1.3.6.1.4.1.171.12.11.1.9.4.1.6INTEGER {other(1), auto(2), stand-alone(3), master(4), slave(5)}read-writecurrent
swUnitMgmtCurrentMode
OBJECT-TYPE
The current stack role of this unit.
1.3.6.1.4.1.171.12.11.1.9.4.1.7INTEGER {other(1), auto(2), stand-alone(3), master(4), slave(5)}read-onlycurrent
swUnitMgmtVersion
OBJECT-TYPE
This object indicates the version of this stacking unit.
1.3.6.1.4.1.171.12.11.1.9.4.1.8DisplayString (SIZE(0..32))read-onlycurrent
swUnitMgmtModuleName
OBJECT-TYPE
A textual string containing module name of the stacking unit.
1.3.6.1.4.1.171.12.11.1.9.4.1.9DisplayString (SIZE(0..32))read-onlycurrent
swDlinkEquipmentNotify
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.2
swEquipmentNotification
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.2.2
swEquipPowerNotification
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.2.2.2
swEquipPowerNotifyPerfix
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.2.2.2.0
swNotificationBindings
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.11.2.3

Notifications

NameOIDStatus
swPowerFailure
NOTIFICATION-TYPE
Power Failure notification.
1.3.6.1.4.1.171.12.11.2.2.2.0.2current
swPowerRecover
NOTIFICATION-TYPE
Power Recover notification.
1.3.6.1.4.1.171.12.11.2.2.2.0.3current