MIBs Depot

DISMAN-EVENT-MIB

Registered at
1.3.6.1.2.1.1.3.0
1.3.6.1.2.1.88
Last updated
2000-10-16 00:00
Organization
IETF Distributed Management Working Group
Revisions
2000-10-16 00:00
Namespace
standard
Source file
DISMAN-EVENT-MIB
Digest
sha256:9d8cdada6da2050c2c4ab40a883c578c2df03cc379ac995338bd7c6a1e301157

Description

The MIB module for defining event triggers and actions for network management purposes.

Contact

Ramanathan Kavasseri Cisco Systems, Inc. 170 West Tasman Drive, San Jose CA 95134-1706. Phone: +1 408 526 4527 Email: ramk@cisco.com

Imports

FromSymbols
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMP-TARGET-MIBSnmpTagValue
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-MIBsysUpTime
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso, mib-2, zeroDotZero
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DISMAN-EVENT-MIB
SNMP-FRAMEWORK-MIB
SNMP-TARGET-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
FailureReason
TEXTUAL-CONVENTION
Reasons for failures in an attempt to perform a management request. The first group of errors, numbered less than 0, are related to problems in sending the request. The existence of a particular error code here does not imply that all implementations are capable of sensing that error and returning that code. The second group, numbered greater than 0, are copied directly from SNMP protocol operations and are intended to carry exactly the meanings defined for the protocol as returned in an SNMP response. localResourceLack some local resource such as memory lacking or mteResourceSampleInstanceMaximum exceeded badDestination unrecognized domain name or otherwise invalid destination address destinationUnreachable can't get to destination address noResponse no response to SNMP request badType the data syntax of a retrieved object as not as expected sampleOverrun another sample attempt occurred before the previous one completed
current

Objects

NameOIDSyntaxAccessStatus
sysUpTimeInstance
OBJECT-IDENTITY
1.3.6.1.2.1.1.3.0
dismanEventMIBObjects
OBJECT-IDENTITY
1.3.6.1.2.1.88.1
mteResource
OBJECT-IDENTITY
1.3.6.1.2.1.88.1.1
mteResourceSampleMinimum
OBJECT-TYPE
The minimum mteTriggerFrequency this system will accept. A system may use the larger values of this minimum to lessen the impact of constant sampling. For larger sampling intervals the system samples less often and suffers less overhead. This object provides a way to enforce such lower overhead for all triggers created after it is set. Unless explicitly resource limited, a system's value for this object SHOULD be 1, allowing as small as a 1 second interval for ongoing trigger sampling. Changing this value will not invalidate an existing setting of mteTriggerFrequency.
1.3.6.1.2.1.88.1.1.1Integer32 (1..2147483647)read-writecurrent
mteResourceSampleInstanceMaximum
OBJECT-TYPE
The maximum number of instance entries this system will support for sampling. These are the entries that maintain state, one for each instance of each sampled object as selected by mteTriggerValueID. Note that wildcarded objects result in multiple instances of this state. A value of 0 indicates no preset limit, that is, the limit is dynamic based on system operation and resources. Unless explicitly resource limited, a system's value for this object SHOULD be 0. Changing this value will not eliminate or inhibit existing sample state but could prevent allocation of additional state information.
1.3.6.1.2.1.88.1.1.2Unsigned32read-writecurrent
mteResourceSampleInstances
OBJECT-TYPE
The number of currently active instance entries as defined for mteResourceSampleInstanceMaximum.
1.3.6.1.2.1.88.1.1.3Gauge32read-onlycurrent
mteResourceSampleInstancesHigh
OBJECT-TYPE
The highest value of mteResourceSampleInstances that has occurred since initialization of the management system.
1.3.6.1.2.1.88.1.1.4Gauge32read-onlycurrent
mteResourceSampleInstanceLacks
OBJECT-TYPE
The number of times this system could not take a new sample because that allocation would have exceeded the limit set by mteResourceSampleInstanceMaximum.
1.3.6.1.2.1.88.1.1.5Counter32read-onlycurrent
mteTrigger
OBJECT-IDENTITY
1.3.6.1.2.1.88.1.2
mteTriggerFailures
OBJECT-TYPE
The number of times an attempt to check for a trigger condition has failed. This counts individually for each attempt in a group of targets or each attempt for a wildcarded object.
1.3.6.1.2.1.88.1.2.1Counter32read-onlycurrent
mteTriggerTable
OBJECT-TYPE
A table of management event trigger information.
1.3.6.1.2.1.88.1.2.2not-accessiblecurrent
mteTriggerEntry
OBJECT-TYPE
Information about a single trigger. Applications create and delete entries using mteTriggerEntryStatus.
1.3.6.1.2.1.88.1.2.2.1not-accessiblecurrent
mteOwner
OBJECT-TYPE
The owner of this entry. The exact semantics of this string are subject to the security policy defined by the security administrator.
1.3.6.1.2.1.88.1.2.2.1.1SnmpAdminString (SIZE(0..32))not-accessiblecurrent
mteTriggerName
OBJECT-TYPE
A locally-unique, administratively assigned name for the trigger within the scope of mteOwner.
1.3.6.1.2.1.88.1.2.2.1.2SnmpAdminString (SIZE(1..32))not-accessiblecurrent
mteTriggerComment
OBJECT-TYPE
A description of the trigger's function and use.
1.3.6.1.2.1.88.1.2.2.1.3SnmpAdminStringread-createcurrent
mteTriggerTest
OBJECT-TYPE
The type of trigger test to perform. For 'boolean' and 'threshold' tests, the object at mteTriggerValueID MUST evaluate to an integer, that is, anything that ends up encoded for transmission (that is, in BER, not ASN.1) as an integer. For 'existence', the specific test is as selected by mteTriggerExistenceTest. When an object appears, vanishes or changes value, the trigger fires. If the object's appearance caused the trigger firing, the object MUST vanish before the trigger can be fired again for it, and vice versa. If the trigger fired due to a change in the object's value, it will be fired again on every successive value change for that object. For 'boolean', the specific test is as selected by mteTriggerBooleanTest. If the test result is true the trigger fires. The trigger will not fire again until the value has become false and come back to true. For 'threshold' the test works as described below for mteTriggerThresholdStartup, mteTriggerThresholdRising, and mteTriggerThresholdFalling. Note that combining 'boolean' and 'threshold' tests on the same object may be somewhat redundant.
1.3.6.1.2.1.88.1.2.2.1.4Bits {existence(0), boolean(1), threshold(2)}read-createcurrent
mteTriggerSampleType
OBJECT-TYPE
The type of sampling to perform. An 'absoluteValue' sample requires only a single sample to be meaningful, and is exactly the value of the object at mteTriggerValueID at the sample time. A 'deltaValue' requires two samples to be meaningful and is thus not available for testing until the second and subsequent samples after the object at mteTriggerValueID is first found to exist. It is the difference between the two samples. For unsigned values it is always positive, based on unsigned arithmetic. For signed values it can be positive or negative. For SNMP counters to be meaningful they should be sampled as a 'deltaValue'. For 'deltaValue' mteTriggerDeltaTable contains further parameters. If only 'existence' is set in mteTriggerTest this object has no meaning.
1.3.6.1.2.1.88.1.2.2.1.5INTEGER {absoluteValue(1), deltaValue(2)}read-createcurrent
mteTriggerValueID
OBJECT-TYPE
The object identifier of the MIB object to sample to see if the trigger should fire. This may be wildcarded by truncating all or part of the instance portion, in which case the value is obtained as if with a GetNext function, checking multiple values if they exist. If such wildcarding is applied, mteTriggerValueIDWildcard must be 'true' and if not it must be 'false'. Bad object identifiers or a mismatch between truncating the identifier and the value of mteTriggerValueIDWildcard result in operation as one would expect when providing the wrong identifier to a Get or GetNext operation. The Get will fail or get the wrong object. The GetNext will indeed get whatever is next, proceeding until it runs past the initial part of the identifier and perhaps many unintended objects for confusing results. If the value syntax of those objects is not usable, that results in a 'badType' error that terminates the scan. Each instance that fills the wildcard is independent of any additional instances, that is, wildcarded objects operate as if there were a separate table entry for each instance that fills the wildcard without having to actually predict all possible instances ahead of time.
1.3.6.1.2.1.88.1.2.2.1.6OBJECT IDENTIFIERread-createcurrent
mteTriggerValueIDWildcard
OBJECT-TYPE
Control for whether mteTriggerValueID is to be treated as fully-specified or wildcarded, with 'true' indicating wildcard.
1.3.6.1.2.1.88.1.2.2.1.7TruthValueread-createcurrent
mteTriggerTargetTag
OBJECT-TYPE
The tag for the target(s) from which to obtain the condition for a trigger check. A length of 0 indicates the local system. In this case, access to the objects indicated by mteTriggerValueID is under the security credentials of the requester that set mteTriggerEntryStatus to 'active'. Those credentials are the input parameters for isAccessAllowed from the Architecture for Describing SNMP Management Frameworks. Otherwise access rights are checked according to the security parameters resulting from the tag.
1.3.6.1.2.1.88.1.2.2.1.8SnmpTagValueread-createcurrent
mteTriggerContextName
OBJECT-TYPE
The management context from which to obtain mteTriggerValueID. This may be wildcarded by leaving characters off the end. For example use 'Repeater' to wildcard to 'Repeater1', 'Repeater2', 'Repeater-999.87b', and so on. To indicate such wildcarding is intended, mteTriggerContextNameWildcard must be 'true'. Each instance that fills the wildcard is independent of any additional instances, that is, wildcarded objects operate as if there were a separate table entry for each instance that fills the wildcard without having to actually predict all possible instances ahead of time. Operation of this feature assumes that the local system has a list of available contexts against which to apply the wildcard. If the objects are being read from the local system, this is clearly the system's own list of contexts. For a remote system a local version of such a list is not defined by any current standard and may not be available, so this function MAY not be supported.
1.3.6.1.2.1.88.1.2.2.1.9SnmpAdminStringread-createcurrent
mteTriggerContextNameWildcard
OBJECT-TYPE
Control for whether mteTriggerContextName is to be treated as fully-specified or wildcarded, with 'true' indicating wildcard.
1.3.6.1.2.1.88.1.2.2.1.10TruthValueread-createcurrent
mteTriggerFrequency
OBJECT-TYPE
The number of seconds to wait between trigger samples. To encourage consistency in sampling, the interval is measured from the beginning of one check to the beginning of the next and the timer is restarted immediately when it expires, not when the check completes. If the next sample begins before the previous one completed the system may either attempt to make the check or treat this as an error condition with the error 'sampleOverrun'. A frequency of 0 indicates instantaneous recognition of the condition. This is not possible in many cases, but may be supported in cases where it makes sense and the system is able to do so. This feature allows the MIB to be used in implementations where such interrupt-driven behavior is possible and is not likely to be supported for all MIB objects even then since such sampling generally has to be tightly integrated into low-level code. Systems that can support this SHOULD document those cases where it can be used. In cases where it can not, setting this object to 0 should be disallowed.
1.3.6.1.2.1.88.1.2.2.1.11Unsigned32read-createcurrent
mteTriggerObjectsOwner
OBJECT-TYPE
To go with mteTriggerObjects, the mteOwner of a group of objects from mteObjectsTable.
1.3.6.1.2.1.88.1.2.2.1.12SnmpAdminString (SIZE(0..32))read-createcurrent
mteTriggerObjects
OBJECT-TYPE
The mteObjectsName of a group of objects from mteObjectsTable. These objects are to be added to any Notification resulting from the firing of this trigger. A list of objects may also be added based on the event or on the value of mteTriggerTest. A length of 0 indicates no additional objects.
1.3.6.1.2.1.88.1.2.2.1.13SnmpAdminString (SIZE(0..32))read-createcurrent
mteTriggerEnabled
OBJECT-TYPE
A control to allow a trigger to be configured but not used. When the value is 'false' the trigger is not sampled.
1.3.6.1.2.1.88.1.2.2.1.14TruthValueread-createcurrent
mteTriggerEntryStatus
OBJECT-TYPE
The control that allows creation and deletion of entries. Once made active an entry may not be modified except to delete it.
1.3.6.1.2.1.88.1.2.2.1.15RowStatusread-createcurrent
mteTriggerDeltaTable
OBJECT-TYPE
A table of management event trigger information for delta sampling.
1.3.6.1.2.1.88.1.2.3not-accessiblecurrent
mteTriggerDeltaEntry
OBJECT-TYPE
Information about a single trigger's delta sampling. Entries automatically exist in this this table for each mteTriggerEntry that has mteTriggerSampleType set to 'deltaValue'.
1.3.6.1.2.1.88.1.2.3.1not-accessiblecurrent
mteTriggerDeltaDiscontinuityID
OBJECT-TYPE
The OBJECT IDENTIFIER (OID) of a TimeTicks, TimeStamp, or DateAndTime object that indicates a discontinuity in the value at mteTriggerValueID. The OID may be for a leaf object (e.g. sysUpTime.0) or may be wildcarded to match mteTriggerValueID. This object supports normal checking for a discontinuity in a counter. Note that if this object does not point to sysUpTime discontinuity checking MUST still check sysUpTime for an overall discontinuity. If the object identified is not accessible the sample attempt is in error, with the error code as from an SNMP request. Bad object identifiers or a mismatch between truncating the identifier and the value of mteDeltaDiscontinuityIDWildcard result in operation as one would expect when providing the wrong identifier to a Get operation. The Get will fail or get the wrong object. If the value syntax of those objects is not usable, that results in an error that terminates the sample with a 'badType' error code.
1.3.6.1.2.1.88.1.2.3.1.1OBJECT IDENTIFIERread-writecurrent
mteTriggerDeltaDiscontinuityIDWildcard
OBJECT-TYPE
Control for whether mteTriggerDeltaDiscontinuityID is to be treated as fully-specified or wildcarded, with 'true' indicating wildcard. Note that the value of this object will be the same as that of the corresponding instance of mteTriggerValueIDWildcard when the corresponding mteTriggerSampleType is 'deltaValue'.
1.3.6.1.2.1.88.1.2.3.1.2TruthValueread-writecurrent
mteTriggerDeltaDiscontinuityIDType
OBJECT-TYPE
The value 'timeTicks' indicates the mteTriggerDeltaDiscontinuityID of this row is of syntax TimeTicks. The value 'timeStamp' indicates syntax TimeStamp. The value 'dateAndTime' indicates syntax DateAndTime.
1.3.6.1.2.1.88.1.2.3.1.3INTEGER {timeTicks(1), timeStamp(2), dateAndTime(3)}read-writecurrent
mteTriggerExistenceTable
OBJECT-TYPE
A table of management event trigger information for existence triggers.
1.3.6.1.2.1.88.1.2.4not-accessiblecurrent
mteTriggerExistenceEntry
OBJECT-TYPE
Information about a single existence trigger. Entries automatically exist in this this table for each mteTriggerEntry that has 'existence' set in mteTriggerTest.
1.3.6.1.2.1.88.1.2.4.1not-accessiblecurrent
mteTriggerExistenceTest
OBJECT-TYPE
The type of existence test to perform. The trigger fires when the object at mteTriggerValueID is seen to go from present to absent, from absent to present, or to have it's value changed, depending on which tests are selected: present(0) - when this test is selected, the trigger fires when the mteTriggerValueID object goes from absent to present. absent(1) - when this test is selected, the trigger fires when the mteTriggerValueID object goes from present to absent. changed(2) - when this test is selected, the trigger fires the mteTriggerValueID object value changes. Once the trigger has fired for either presence or absence it will not fire again for that state until the object has been to the other state.
1.3.6.1.2.1.88.1.2.4.1.1Bits {present(0), absent(1), changed(2)}read-writecurrent
mteTriggerExistenceStartup
OBJECT-TYPE
Control for whether an event may be triggered when this entry is first set to 'active' and the test specified by mteTriggerExistenceTest is true. Setting an option causes that trigger to fire when its test is true.
1.3.6.1.2.1.88.1.2.4.1.2Bits {present(0), absent(1)}read-writecurrent
mteTriggerExistenceObjectsOwner
OBJECT-TYPE
To go with mteTriggerExistenceObjects, the mteOwner of a group of objects from mteObjectsTable.
1.3.6.1.2.1.88.1.2.4.1.3SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerExistenceObjects
OBJECT-TYPE
The mteObjectsName of a group of objects from mteObjectsTable. These objects are to be added to any Notification resulting from the firing of this trigger for this test. A list of objects may also be added based on the overall trigger, the event or other settings in mteTriggerTest. A length of 0 indicates no additional objects.
1.3.6.1.2.1.88.1.2.4.1.4SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerExistenceEventOwner
OBJECT-TYPE
To go with mteTriggerExistenceEvent, the mteOwner of an event entry from the mteEventTable.
1.3.6.1.2.1.88.1.2.4.1.5SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerExistenceEvent
OBJECT-TYPE
The mteEventName of the event to invoke when mteTriggerType is 'existence' and this trigger fires. A length of 0 indicates no event.
1.3.6.1.2.1.88.1.2.4.1.6SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerBooleanTable
OBJECT-TYPE
A table of management event trigger information for boolean triggers.
1.3.6.1.2.1.88.1.2.5not-accessiblecurrent
mteTriggerBooleanEntry
OBJECT-TYPE
Information about a single boolean trigger. Entries automatically exist in this this table for each mteTriggerEntry that has 'boolean' set in mteTriggerTest.
1.3.6.1.2.1.88.1.2.5.1not-accessiblecurrent
mteTriggerBooleanComparison
OBJECT-TYPE
The type of boolean comparison to perform. The value at mteTriggerValueID is compared to mteTriggerBooleanValue, so for example if mteTriggerBooleanComparison is 'less' the result would be true if the value at mteTriggerValueID is less than the value of mteTriggerBooleanValue.
1.3.6.1.2.1.88.1.2.5.1.1INTEGER {unequal(1), equal(2), less(3), lessOrEqual(4), greater(5), greaterOrEqual(6)}read-writecurrent
mteTriggerBooleanValue
OBJECT-TYPE
The value to use for the test specified by mteTriggerBooleanTest.
1.3.6.1.2.1.88.1.2.5.1.2Integer32read-writecurrent
mteTriggerBooleanStartup
OBJECT-TYPE
Control for whether an event may be triggered when this entry is first set to 'active' or a new instance of the object at mteTriggerValueID is found and the test specified by mteTriggerBooleanComparison is true. In that case an event is triggered if mteTriggerBooleanStartup is 'true'.
1.3.6.1.2.1.88.1.2.5.1.3TruthValueread-writecurrent
mteTriggerBooleanObjectsOwner
OBJECT-TYPE
To go with mteTriggerBooleanObjects, the mteOwner of a group of objects from mteObjectsTable.
1.3.6.1.2.1.88.1.2.5.1.4SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerBooleanObjects
OBJECT-TYPE
The mteObjectsName of a group of objects from mteObjectsTable. These objects are to be added to any Notification resulting from the firing of this trigger for this test. A list of objects may also be added based on the overall trigger, the event or other settings in mteTriggerTest. A length of 0 indicates no additional objects.
1.3.6.1.2.1.88.1.2.5.1.5SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerBooleanEventOwner
OBJECT-TYPE
To go with mteTriggerBooleanEvent, the mteOwner of an event entry from mteEventTable.
1.3.6.1.2.1.88.1.2.5.1.6SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerBooleanEvent
OBJECT-TYPE
The mteEventName of the event to invoke when mteTriggerType is 'boolean' and this trigger fires. A length of 0 indicates no event.
1.3.6.1.2.1.88.1.2.5.1.7SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdTable
OBJECT-TYPE
A table of management event trigger information for threshold triggers.
1.3.6.1.2.1.88.1.2.6not-accessiblecurrent
mteTriggerThresholdEntry
OBJECT-TYPE
Information about a single threshold trigger. Entries automatically exist in this table for each mteTriggerEntry that has 'threshold' set in mteTriggerTest.
1.3.6.1.2.1.88.1.2.6.1not-accessiblecurrent
mteTriggerThresholdStartup
OBJECT-TYPE
The event that may be triggered when this entry is first set to 'active' and a new instance of the object at mteTriggerValueID is found. If the first sample after this instance becomes active is greater than or equal to mteTriggerThresholdRising and mteTriggerThresholdStartup is equal to 'rising' or 'risingOrFalling', then one mteTriggerThresholdRisingEvent is triggered for that instance. If the first sample after this entry becomes active is less than or equal to mteTriggerThresholdFalling and mteTriggerThresholdStartup is equal to 'falling' or 'risingOrFalling', then one mteTriggerThresholdRisingEvent is triggered for that instance.
1.3.6.1.2.1.88.1.2.6.1.1INTEGER {rising(1), falling(2), risingOrFalling(3)}read-writecurrent
mteTriggerThresholdRising
OBJECT-TYPE
A threshold value to check against if mteTriggerType is 'threshold'. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, one mteTriggerThresholdRisingEvent is triggered. That event is also triggered if the first sample after this entry becomes active is greater than or equal to this threshold and mteTriggerThresholdStartup is equal to 'rising' or 'risingOrFalling'. After a rising event is generated, another such event is not triggered until the sampled value falls below this threshold and reaches mteTriggerThresholdFalling.
1.3.6.1.2.1.88.1.2.6.1.2Integer32read-writecurrent
mteTriggerThresholdFalling
OBJECT-TYPE
A threshold value to check against if mteTriggerType is 'threshold'. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, one mteTriggerThresholdFallingEvent is triggered. That event is also triggered if the first sample after this entry becomes active is less than or equal to this threshold and mteTriggerThresholdStartup is equal to 'falling' or 'risingOrFalling'. After a falling event is generated, another such event is not triggered until the sampled value rises above this threshold and reaches mteTriggerThresholdRising.
1.3.6.1.2.1.88.1.2.6.1.3Integer32read-writecurrent
mteTriggerThresholdDeltaRising
OBJECT-TYPE
A threshold value to check against if mteTriggerType is 'threshold'. When the delta value (difference) between the current sampled value (value(n)) and the previous sampled value (value(n-1)) is greater than or equal to this threshold, and the delta value calculated at the last sampling interval (i.e. value(n-1) - value(n-2)) was less than this threshold, one mteTriggerThresholdDeltaRisingEvent is triggered. That event is also triggered if the first delta value calculated after this entry becomes active, i.e. value(2) - value(1), where value(1) is the first sample taken of that instance, is greater than or equal to this threshold. After a rising event is generated, another such event is not triggered until the delta value falls below this threshold and reaches mteTriggerThresholdDeltaFalling.
1.3.6.1.2.1.88.1.2.6.1.4Integer32read-writecurrent
mteTriggerThresholdDeltaFalling
OBJECT-TYPE
A threshold value to check against if mteTriggerType is 'threshold'. When the delta value (difference) between the current sampled value (value(n)) and the previous sampled value (value(n-1)) is less than or equal to this threshold, and the delta value calculated at the last sampling interval (i.e. value(n-1) - value(n-2)) was greater than this threshold, one mteTriggerThresholdDeltaFallingEvent is triggered. That event is also triggered if the first delta value calculated after this entry becomes active, i.e. value(2) - value(1), where value(1) is the first sample taken of that instance, is less than or equal to this threshold. After a falling event is generated, another such event is not triggered until the delta value falls below this threshold and reaches mteTriggerThresholdDeltaRising.
1.3.6.1.2.1.88.1.2.6.1.5Integer32read-writecurrent
mteTriggerThresholdObjectsOwner
OBJECT-TYPE
To go with mteTriggerThresholdObjects, the mteOwner of a group of objects from mteObjectsTable.
1.3.6.1.2.1.88.1.2.6.1.6SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdObjects
OBJECT-TYPE
The mteObjectsName of a group of objects from mteObjectsTable. These objects are to be added to any Notification resulting from the firing of this trigger for this test. A list of objects may also be added based on the overall trigger, the event or other settings in mteTriggerTest. A length of 0 indicates no additional objects.
1.3.6.1.2.1.88.1.2.6.1.7SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdRisingEventOwner
OBJECT-TYPE
To go with mteTriggerThresholdRisingEvent, the mteOwner of an event entry from mteEventTable.
1.3.6.1.2.1.88.1.2.6.1.8SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdRisingEvent
OBJECT-TYPE
The mteEventName of the event to invoke when mteTriggerType is 'threshold' and this trigger fires based on mteTriggerThresholdRising. A length of 0 indicates no event.
1.3.6.1.2.1.88.1.2.6.1.9SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdFallingEventOwner
OBJECT-TYPE
To go with mteTriggerThresholdFallingEvent, the mteOwner of an event entry from mteEventTable.
1.3.6.1.2.1.88.1.2.6.1.10SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdFallingEvent
OBJECT-TYPE
The mteEventName of the event to invoke when mteTriggerType is 'threshold' and this trigger fires based on mteTriggerThresholdFalling. A length of 0 indicates no event.
1.3.6.1.2.1.88.1.2.6.1.11SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdDeltaRisingEventOwner
OBJECT-TYPE
To go with mteTriggerThresholdDeltaRisingEvent, the mteOwner of an event entry from mteEventTable.
1.3.6.1.2.1.88.1.2.6.1.12SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdDeltaRisingEvent
OBJECT-TYPE
The mteEventName of the event to invoke when mteTriggerType is 'threshold' and this trigger fires based on mteTriggerThresholdDeltaRising. A length of 0 indicates no event.
1.3.6.1.2.1.88.1.2.6.1.13SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdDeltaFallingEventOwner
OBJECT-TYPE
To go with mteTriggerThresholdDeltaFallingEvent, the mteOwner of an event entry from mteEventTable.
1.3.6.1.2.1.88.1.2.6.1.14SnmpAdminString (SIZE(0..32))read-writecurrent
mteTriggerThresholdDeltaFallingEvent
OBJECT-TYPE
The mteEventName of the event to invoke when mteTriggerType is 'threshold' and this trigger fires based on mteTriggerThresholdDeltaFalling. A length of 0 indicates no event.
1.3.6.1.2.1.88.1.2.6.1.15SnmpAdminString (SIZE(0..32))read-writecurrent
mteObjects
OBJECT-IDENTITY
1.3.6.1.2.1.88.1.3
mteObjectsTable
OBJECT-TYPE
A table of objects that can be added to notifications based on the trigger, trigger test, or event, as pointed to by entries in those tables.
1.3.6.1.2.1.88.1.3.1not-accessiblecurrent
mteObjectsEntry
OBJECT-TYPE
A group of objects. Applications create and delete entries using mteObjectsEntryStatus. When adding objects to a notification they are added in the lexical order of their index in this table. Those associated with a trigger come first, then trigger test, then event.
1.3.6.1.2.1.88.1.3.1.1not-accessiblecurrent
mteObjectsName
OBJECT-TYPE
A locally-unique, administratively assigned name for a group of objects.
1.3.6.1.2.1.88.1.3.1.1.1SnmpAdminString (SIZE(1..32))not-accessiblecurrent
mteObjectsIndex
OBJECT-TYPE
An arbitrary integer for the purpose of identifying individual objects within a mteObjectsName group. Objects within a group are placed in the notification in the numerical order of this index. Groups are placed in the notification in the order of the selections for overall trigger, trigger test, and event. Within trigger test they are in the same order as the numerical values of the bits defined for mteTriggerTest. Bad object identifiers or a mismatch between truncating the identifier and the value of mteDeltaDiscontinuityIDWildcard result in operation as one would expect when providing the wrong identifier to a Get operation. The Get will fail or get the wrong object. If the object is not available it is omitted from the notification.
1.3.6.1.2.1.88.1.3.1.1.2Unsigned32 (1..4294967295)not-accessiblecurrent
mteObjectsID
OBJECT-TYPE
The object identifier of a MIB object to add to a Notification that results from the firing of a trigger. This may be wildcarded by truncating all or part of the instance portion, in which case the instance portion of the OID for obtaining this object will be the same as that used in obtaining the mteTriggerValueID that fired. If such wildcarding is applied, mteObjectsIDWildcard must be 'true' and if not it must be 'false'. Each instance that fills the wildcard is independent of any additional instances, that is, wildcarded objects operate as if there were a separate table entry for each instance that fills the wildcard without having to actually predict all possible instances ahead of time.
1.3.6.1.2.1.88.1.3.1.1.3OBJECT IDENTIFIERread-createcurrent
mteObjectsIDWildcard
OBJECT-TYPE
Control for whether mteObjectsID is to be treated as fully-specified or wildcarded, with 'true' indicating wildcard.
1.3.6.1.2.1.88.1.3.1.1.4TruthValueread-createcurrent
mteObjectsEntryStatus
OBJECT-TYPE
The control that allows creation and deletion of entries. Once made active an entry MAY not be modified except to delete it.
1.3.6.1.2.1.88.1.3.1.1.5RowStatusread-createcurrent
mteEvent
OBJECT-IDENTITY
1.3.6.1.2.1.88.1.4
mteEventFailures
OBJECT-TYPE
The number of times an attempt to invoke an event has failed. This counts individually for each attempt in a group of targets or each attempt for a wildcarded trigger object.
1.3.6.1.2.1.88.1.4.1Counter32read-onlycurrent
mteEventTable
OBJECT-TYPE
A table of management event action information.
1.3.6.1.2.1.88.1.4.2not-accessiblecurrent
mteEventEntry
OBJECT-TYPE
Information about a single event. Applications create and delete entries using mteEventEntryStatus.
1.3.6.1.2.1.88.1.4.2.1not-accessiblecurrent
mteEventName
OBJECT-TYPE
A locally-unique, administratively assigned name for the event.
1.3.6.1.2.1.88.1.4.2.1.1SnmpAdminString (SIZE(1..32))not-accessiblecurrent
mteEventComment
OBJECT-TYPE
A description of the event's function and use.
1.3.6.1.2.1.88.1.4.2.1.2SnmpAdminStringread-createcurrent
mteEventActions
OBJECT-TYPE
The actions to perform when this event occurs. For 'notification', Traps and/or Informs are sent according to the configuration in the SNMP Notification MIB. For 'set', an SNMP Set operation is performed according to control values in this entry.
1.3.6.1.2.1.88.1.4.2.1.3Bits {notification(0), set(1)}read-createcurrent
mteEventEnabled
OBJECT-TYPE
A control to allow an event to be configured but not used. When the value is 'false' the event does not execute even if triggered.
1.3.6.1.2.1.88.1.4.2.1.4TruthValueread-createcurrent
mteEventEntryStatus
OBJECT-TYPE
The control that allows creation and deletion of entries. Once made active an entry MAY not be modified except to delete it.
1.3.6.1.2.1.88.1.4.2.1.5RowStatusread-createcurrent
mteEventNotificationTable
OBJECT-TYPE
A table of information about notifications to be sent as a consequence of management events.
1.3.6.1.2.1.88.1.4.3not-accessiblecurrent
mteEventNotificationEntry
OBJECT-TYPE
Information about a single event's notification. Entries automatically exist in this this table for each mteEventEntry that has 'notification' set in mteEventActions.
1.3.6.1.2.1.88.1.4.3.1not-accessiblecurrent
mteEventNotification
OBJECT-TYPE
The object identifier from the NOTIFICATION-TYPE for the notification to use if metEventActions has 'notification' set.
1.3.6.1.2.1.88.1.4.3.1.1OBJECT IDENTIFIERread-writecurrent
mteEventNotificationObjectsOwner
OBJECT-TYPE
To go with mteEventNotificationObjects, the mteOwner of a group of objects from mteObjectsTable.
1.3.6.1.2.1.88.1.4.3.1.2SnmpAdminString (SIZE(0..32))read-writecurrent
mteEventNotificationObjects
OBJECT-TYPE
The mteObjectsName of a group of objects from mteObjectsTable if mteEventActions has 'notification' set. These objects are to be added to any Notification generated by this event. Objects may also be added based on the trigger that stimulated the event. A length of 0 indicates no additional objects.
1.3.6.1.2.1.88.1.4.3.1.3SnmpAdminString (SIZE(0..32))read-writecurrent
mteEventSetTable
OBJECT-TYPE
A table of management event action information.
1.3.6.1.2.1.88.1.4.4not-accessiblecurrent
mteEventSetEntry
OBJECT-TYPE
Information about a single event's set option. Entries automatically exist in this this table for each mteEventEntry that has 'set' set in mteEventActions.
1.3.6.1.2.1.88.1.4.4.1not-accessiblecurrent
mteEventSetObject
OBJECT-TYPE
The object identifier from the MIB object to set if mteEventActions has 'set' set. This object identifier may be wildcarded by leaving sub-identifiers off the end, in which case nteEventSetObjectWildCard must be 'true'. If mteEventSetObject is wildcarded the instance used to set the object to which it points is the same as the instance from the value of mteTriggerValueID that triggered the event. Each instance that fills the wildcard is independent of any additional instances, that is, wildcarded objects operate as if there were a separate table entry for each instance that fills the wildcard without having to actually predict all possible instances ahead of time. Bad object identifiers or a mismatch between truncating the identifier and the value of mteSetObjectWildcard result in operation as one would expect when providing the wrong identifier to a Set operation. The Set will fail or set the wrong object. If the value syntax of the destination object is not correct, the Set fails with the normal SNMP error code.
1.3.6.1.2.1.88.1.4.4.1.1OBJECT IDENTIFIERread-writecurrent
mteEventSetObjectWildcard
OBJECT-TYPE
Control over whether mteEventSetObject is to be treated as fully-specified or wildcarded, with 'true' indicating wildcard if mteEventActions has 'set' set.
1.3.6.1.2.1.88.1.4.4.1.2TruthValueread-writecurrent
mteEventSetValue
OBJECT-TYPE
The value to which to set the object at mteEventSetObject if mteEventActions has 'set' set.
1.3.6.1.2.1.88.1.4.4.1.3Integer32read-writecurrent
mteEventSetTargetTag
OBJECT-TYPE
The tag for the target(s) at which to set the object at mteEventSetObject to mteEventSetValue if mteEventActions has 'set' set. Systems limited to self management MAY reject a non-zero length for the value of this object. A length of 0 indicates the local system. In this case, access to the objects indicated by mteEventSetObject is under the security credentials of the requester that set mteTriggerEntryStatus to 'active'. Those credentials are the input parameters for isAccessAllowed from the Architecture for Describing SNMP Management Frameworks. Otherwise access rights are checked according to the security parameters resulting from the tag.
1.3.6.1.2.1.88.1.4.4.1.4SnmpTagValueread-writecurrent
mteEventSetContextName
OBJECT-TYPE
The management context in which to set mteEventObjectID. if mteEventActions has 'set' set. This may be wildcarded by leaving characters off the end. To indicate such wildcarding mteEventSetContextNameWildcard must be 'true'. If this context name is wildcarded the value used to complete the wildcarding of mteTriggerContextName will be appended.
1.3.6.1.2.1.88.1.4.4.1.5SnmpAdminStringread-writecurrent
mteEventSetContextNameWildcard
OBJECT-TYPE
Control for whether mteEventSetContextName is to be treated as fully-specified or wildcarded, with 'true' indicating wildcard if mteEventActions has 'set' set.
1.3.6.1.2.1.88.1.4.4.1.6TruthValueread-writecurrent
dismanEventMIBNotificationPrefix
OBJECT-IDENTITY
1.3.6.1.2.1.88.2
dismanEventMIBNotifications
OBJECT-IDENTITY
1.3.6.1.2.1.88.2.0
dismanEventMIBNotificationObjects
OBJECT-IDENTITY
1.3.6.1.2.1.88.2.1
mteHotTrigger
OBJECT-TYPE
The name of the trigger causing the notification.
1.3.6.1.2.1.88.2.1.1SnmpAdminStringaccessible-for-notifycurrent
mteHotTargetName
OBJECT-TYPE
The SNMP Target MIB's snmpTargetAddrName related to the notification.
1.3.6.1.2.1.88.2.1.2SnmpAdminStringaccessible-for-notifycurrent
mteHotContextName
OBJECT-TYPE
The context name related to the notification. This MUST be as fully-qualified as possible, including filling in wildcard information determined in processing.
1.3.6.1.2.1.88.2.1.3SnmpAdminStringaccessible-for-notifycurrent
mteHotOID
OBJECT-TYPE
The object identifier of the destination object related to the notification. This MUST be as fully-qualified as possible, including filling in wildcard information determined in processing. For a trigger-related notification this is from mteTriggerValueID. For a set failure this is from mteEventSetObject.
1.3.6.1.2.1.88.2.1.4OBJECT IDENTIFIERaccessible-for-notifycurrent
mteHotValue
OBJECT-TYPE
The value of the object at mteTriggerValueID when a trigger fired.
1.3.6.1.2.1.88.2.1.5Integer32accessible-for-notifycurrent
mteFailedReason
OBJECT-TYPE
The reason for the failure of an attempt to check for a trigger condition or set an object in response to an event.
1.3.6.1.2.1.88.2.1.6FailureReasonaccessible-for-notifycurrent
dismanEventMIBConformance
OBJECT-IDENTITY
1.3.6.1.2.1.88.3
dismanEventMIBCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.88.3.1
dismanEventMIBGroups
OBJECT-IDENTITY
1.3.6.1.2.1.88.3.2

Notifications

NameOIDStatus
mteTriggerFired
NOTIFICATION-TYPE
Notification that the trigger indicated by the object instances has fired, for triggers with mteTriggerType 'boolean' or 'existence'.
1.3.6.1.2.1.88.2.0.1current
mteTriggerRising
NOTIFICATION-TYPE
Notification that the rising threshold was met for triggers with mteTriggerType 'threshold'.
1.3.6.1.2.1.88.2.0.2current
mteTriggerFalling
NOTIFICATION-TYPE
Notification that the falling threshold was met for triggers with mteTriggerType 'threshold'.
1.3.6.1.2.1.88.2.0.3current
mteTriggerFailure
NOTIFICATION-TYPE
Notification that an attempt to check a trigger has failed. The network manager must enable this notification only with a certain fear and trembling, as it can easily crowd out more important information. It should be used only to help diagnose a problem that has appeared in the error counters and can not be found otherwise.
1.3.6.1.2.1.88.2.0.4current
mteEventSetFailure
NOTIFICATION-TYPE
Notification that an attempt to do a set in response to an event has failed. The network manager must enable this notification only with a certain fear and trembling, as it can easily crowd out more important information. It should be used only to help diagnose a problem that has appeared in the error counters and can not be found otherwise.
1.3.6.1.2.1.88.2.0.5current

Conformance

NameOIDStatus
dismanEventMIBCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement the Event MIB.
1.3.6.1.2.1.88.3.1.1current
dismanEventResourceGroup
OBJECT-GROUP
Event resource status and control objects.
1.3.6.1.2.1.88.3.2.1current
dismanEventTriggerGroup
OBJECT-GROUP
Event triggers.
1.3.6.1.2.1.88.3.2.2current
dismanEventObjectsGroup
OBJECT-GROUP
Supplemental objects.
1.3.6.1.2.1.88.3.2.3current
dismanEventEventGroup
OBJECT-GROUP
Events.
1.3.6.1.2.1.88.3.2.4current
dismanEventNotificationObjectGroup
OBJECT-GROUP
Notification objects.
1.3.6.1.2.1.88.3.2.5current
dismanEventNotificationGroup
NOTIFICATION-GROUP
Notifications.
1.3.6.1.2.1.88.3.2.6current