MIBs Depot

DIGIPDU-MIB

Registered at
1.3.6.1.4.1.10456
Last updated
2009-04-16 16:27
Revisions
2009-04-16 16:27
Namespace
planet
Source file
DIGIPDU-MIB
Digest
sha256:131ef441712b37e40e8a2cdb3a335fff972c7a3053952fd1743629cb74a95219

Description

This is the MIB module for the All DIGIPDU Device

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DIGIPDU-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
digipdu
OBJECT-IDENTITY
1.3.6.1.4.1.10456
product
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.1
productModel
OBJECT-TYPE
Indicate the Model of Device.
1.3.6.1.4.1.10456.3.1.1DisplayString (SIZE(0..50))read-onlycurrent
productPartNumber
OBJECT-TYPE
The part number of this appliance as shown on the label.
1.3.6.1.4.1.10456.3.1.2DisplayString (SIZE(0..32))read-onlycurrent
productSerialNumber
OBJECT-TYPE
The serial number of this appliance as shown on the label.
1.3.6.1.4.1.10456.3.1.3DisplayString (SIZE(0..32))read-onlycurrent
productFirmwareVersion
OBJECT-TYPE
The version of the firmware of this product.
1.3.6.1.4.1.10456.3.1.4DisplayString (SIZE(0..32))read-onlycurrent
productTemperatureKind
OBJECT-TYPE
Temperature Kind(0:CELSIUS, 1:FAHRENHEIT).
1.3.6.1.4.1.10456.3.1.11INTEGER (0..1)read-onlycurrent
productResetDetector
OBJECT-TYPE
Display the Nearest Operated Time of Reset Buttom.
1.3.6.1.4.1.10456.3.1.21DisplayStringread-onlycurrent
deviceTable
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.2
deviceATSKind
OBJECT-TYPE
Device ATS Kind.
1.3.6.1.4.1.10456.3.2.1INTEGER (1..3)read-onlycurrent
deviceInFeedTotal
OBJECT-TYPE
Input Feed Total.
1.3.6.1.4.1.10456.3.2.2INTEGER (1..3)read-onlycurrent
deviceInFeedKind
OBJECT-TYPE
Input Feed Kind.
1.3.6.1.4.1.10456.3.2.3INTEGER (1..4)read-onlycurrent
deviceInFeedBranch
OBJECT-TYPE
Input Feed Kind.
1.3.6.1.4.1.10456.3.2.4INTEGER (1..2)read-onlycurrent
deviceOutTotal
OBJECT-TYPE
Out Total.
1.3.6.1.4.1.10456.3.2.5INTEGER (1..24)read-onlycurrent
deviceOutKind
OBJECT-TYPE
Out Kind.
1.3.6.1.4.1.10456.3.2.6INTEGER (1..4)read-onlycurrent
deviceInbuiltTempTotal
OBJECT-TYPE
Inbuilt Temperature Total.
1.3.6.1.4.1.10456.3.2.7INTEGER (0..1)read-onlycurrent
deviceExtendTemperatureTotal
OBJECT-TYPE
Extend ENV Total.
1.3.6.1.4.1.10456.3.2.8INTEGER (0..6)read-onlycurrent
deviceExtendRHTotal
OBJECT-TYPE
Extend ENV Total.
1.3.6.1.4.1.10456.3.2.9INTEGER (0..4)read-onlycurrent
devicePDUTotal
OBJECT-TYPE
PDU Total.
1.3.6.1.4.1.10456.3.2.10INTEGER (1..8)read-onlycurrent
deviceInputTotal
OBJECT-TYPE
Input Total.
1.3.6.1.4.1.10456.3.2.11INTEGER (1..8)read-onlycurrent
deviceUPS
OBJECT-TYPE
UPS.
1.3.6.1.4.1.10456.3.2.12INTEGER {no(0), yes(1)}read-onlycurrent
deviceDaisyChain
OBJECT-TYPE
Daisy Chain.
1.3.6.1.4.1.10456.3.2.13INTEGER {no(0), yes(1)}read-onlycurrent
deviceUnitTotal
OBJECT-TYPE
Device Unit Total.
1.3.6.1.4.1.10456.3.2.20INTEGER (1..16)read-onlycurrent
deviceUnitTable
OBJECT-TYPE
The table of Device Unit.
1.3.6.1.4.1.10456.3.2.21not-accessiblecurrent
deviceUnitEntry
OBJECT-TYPE
Row definition for Device Unit table.
1.3.6.1.4.1.10456.3.2.21.1not-accessiblecurrent
deviceUnitIndex
OBJECT-TYPE
Device Unit table index.
1.3.6.1.4.1.10456.3.2.21.1.1INTEGER (1..16)read-onlycurrent
deviceUnitStatus
OBJECT-TYPE
status in the Device Unit.
1.3.6.1.4.1.10456.3.2.21.1.2INTEGERread-onlycurrent
deviceUnitInfeedTotal
OBJECT-TYPE
Infeed Total of Device Unit.
1.3.6.1.4.1.10456.3.2.21.1.3INTEGERread-onlycurrent
deviceUnitOutTotal
OBJECT-TYPE
Out Total of Device Unit.
1.3.6.1.4.1.10456.3.2.21.1.4INTEGERread-onlycurrent
peripheralTables
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.3
aTSTable
OBJECT-TYPE
The table of Auto Transfer Switch.
1.3.6.1.4.1.10456.3.3.1not-accessiblecurrent
aTSEntry
OBJECT-TYPE
Row definition for Input Feed table.
1.3.6.1.4.1.10456.3.3.1.1not-accessiblecurrent
aTSIndex
OBJECT-TYPE
Auto Transfer Switch table index.
1.3.6.1.4.1.10456.3.3.1.1.1INTEGER (1..2)read-onlycurrent
aTSStatus
OBJECT-TYPE
status in the Auto Transfer Switch.
1.3.6.1.4.1.10456.3.3.1.1.2INTEGERread-onlycurrent
aTSVoltage
OBJECT-TYPE
Voltage of Auto Transfer Switch.
1.3.6.1.4.1.10456.3.3.1.1.3INTEGERread-onlycurrent
aTSFrequency
OBJECT-TYPE
Frequency of Auto Transfer Switch.
1.3.6.1.4.1.10456.3.3.1.1.4INTEGERread-onlycurrent
inFeedTable
OBJECT-TYPE
The table of Input Feed.
1.3.6.1.4.1.10456.3.3.2not-accessiblecurrent
inFeedEntry
OBJECT-TYPE
Row definition for Input Feed table.
1.3.6.1.4.1.10456.3.3.2.1not-accessiblecurrent
inFeedIndex
OBJECT-TYPE
Input Feed table index.
1.3.6.1.4.1.10456.3.3.2.1.1INTEGER (1..3)read-onlycurrent
inFeedStatus
OBJECT-TYPE
status in the Input Feed.
1.3.6.1.4.1.10456.3.3.2.1.2INTEGERread-onlycurrent
inFeedVoltage
OBJECT-TYPE
Voltage of Input Feed.
1.3.6.1.4.1.10456.3.3.2.1.3INTEGERread-onlycurrent
inFeedFrequency
OBJECT-TYPE
Frequency of Input Feed.
1.3.6.1.4.1.10456.3.3.2.1.4INTEGERread-onlycurrent
inFeedCurrent
OBJECT-TYPE
Total Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.5INTEGERread-onlycurrent
inFeedPowerLoad
OBJECT-TYPE
Actual value of power in the Input Feed.
1.3.6.1.4.1.10456.3.3.2.1.6INTEGERread-onlycurrent
inFeedPowerFactor
OBJECT-TYPE
Actual value of power factor in the Input Feed.
1.3.6.1.4.1.10456.3.3.2.1.7INTEGERread-onlycurrent
inFeedPowerEnergy
OBJECT-TYPE
Actual value of energy in the Input Feed.
1.3.6.1.4.1.10456.3.3.2.1.8INTEGERread-onlycurrent
inFeedOverLoad
OBJECT-TYPE
OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.9INTEGERread-writecurrent
inFeedHighWarning
OBJECT-TYPE
High Warning of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.10INTEGERread-writecurrent
inFeedLowWarning
OBJECT-TYPE
Low Warning of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.11INTEGERread-writecurrent
inFeedBranch
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.12INTEGERread-onlycurrent
inFeedBranch1Current
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.13INTEGERread-onlycurrent
inFeedBranch1PowerLoad
OBJECT-TYPE
Actual value of power in the PDU.
1.3.6.1.4.1.10456.3.3.2.1.14INTEGERread-onlycurrent
inFeedBranch1PowerFactor
OBJECT-TYPE
Actual value of power factor in the PDU.
1.3.6.1.4.1.10456.3.3.2.1.15INTEGERread-onlycurrent
inFeedBranch1OverLoad
OBJECT-TYPE
OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.16INTEGERread-writecurrent
inFeedBranch1HighWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.17INTEGERread-writecurrent
inFeedBranch1LowWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.18INTEGERread-writecurrent
inFeedBranch2Current
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.19INTEGERread-onlycurrent
inFeedBranch2PowerLoad
OBJECT-TYPE
Actual value of power in the PDU.
1.3.6.1.4.1.10456.3.3.2.1.20INTEGERread-onlycurrent
inFeedBranch2PowerFactor
OBJECT-TYPE
Actual value of power factor in the PDU.
1.3.6.1.4.1.10456.3.3.2.1.21INTEGERread-onlycurrent
inFeedBranch2OverLoad
OBJECT-TYPE
OverLoad of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.22INTEGERread-writecurrent
inFeedBranch2HighWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.23INTEGERread-writecurrent
inFeedBranch2LowWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.2.1.24INTEGERread-writecurrent
outTable
OBJECT-TYPE
The table of Outlet.
1.3.6.1.4.1.10456.3.3.3not-accessiblecurrent
outEntry
OBJECT-TYPE
Row definition for Outlet table.
1.3.6.1.4.1.10456.3.3.3.1not-accessiblecurrent
outIndex
OBJECT-TYPE
Out table index.
1.3.6.1.4.1.10456.3.3.3.1.1INTEGER (1..24)read-onlycurrent
outComputerStatus
OBJECT-TYPE
Out computer status.
1.3.6.1.4.1.10456.3.3.3.1.2INTEGERread-onlycurrent
outCurrentStatus
OBJECT-TYPE
Out Current status.
1.3.6.1.4.1.10456.3.3.3.1.3INTEGERread-onlycurrent
outSwitchStatus
OBJECT-TYPE
This OID is provided for Outlet Status information. '0' if the out is Switch Off. '1' if the out is Switch On. '2' if the out is Switch Off Acting. '3' if the out is Switch On Acting.
1.3.6.1.4.1.10456.3.3.3.1.4INTEGER {off(0), on(1), off-act(2), on-act(3)}read-onlycurrent
outSwitchCtrl
OBJECT-TYPE
This OID is provided for Outlet Status information. '0' if the out is None. '1' Switch Ctrl On. '2' Switch Ctrl Off. '3' Switch Ctrl Reboot. '4' Switch Ctrl On Off.
1.3.6.1.4.1.10456.3.3.3.1.5INTEGER {none(0), ctrl-on(1), ctrl-off(2), ctrl-reboot(3), ctrl-on-off(4)}read-writecurrent
outVoltage
OBJECT-TYPE
Voltage of Outlet.
1.3.6.1.4.1.10456.3.3.3.1.6INTEGERread-onlycurrent
outCurrent
OBJECT-TYPE
Current of Outlet(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.3.1.7INTEGERread-onlycurrent
outPowerFactor
OBJECT-TYPE
Actual value of power factor in the Outlet.
1.3.6.1.4.1.10456.3.3.3.1.8INTEGERread-onlycurrent
outPowerLoad
OBJECT-TYPE
Actual value of power in the Outlet.
1.3.6.1.4.1.10456.3.3.3.1.9INTEGERread-onlycurrent
outOverload
OBJECT-TYPE
Overload of Outlet(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.3.1.10INTEGERread-writecurrent
outHighWarning
OBJECT-TYPE
High Warning of Outlet(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.3.1.11INTEGERread-writecurrent
outLowWarning
OBJECT-TYPE
Low Warning of Outlet(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.3.1.12INTEGERread-writecurrent
pduTables
OBJECT-TYPE
The table of PDU.
1.3.6.1.4.1.10456.3.3.4not-accessiblecurrent
pduEntry
OBJECT-TYPE
Row definition for PDU table.
1.3.6.1.4.1.10456.3.3.4.1not-accessiblecurrent
pduIndex
OBJECT-TYPE
PDU table index.
1.3.6.1.4.1.10456.3.3.4.1.1INTEGER (1..8)read-onlycurrent
pduModel
OBJECT-TYPE
Now Power Data Log of PDU(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.2DisplayStringread-onlycurrent
pduMonitor
OBJECT-TYPE
PDU Monitor Status.
1.3.6.1.4.1.10456.3.3.4.1.3INTEGER {no(0), yes(1)}read-writecurrent
pduStatus
OBJECT-TYPE
PDU Connect Status.
1.3.6.1.4.1.10456.3.3.4.1.4INTEGER {no(0), yes(1), warning(2)}read-onlycurrent
pduVoltage
OBJECT-TYPE
Voltage of PDU.
1.3.6.1.4.1.10456.3.3.4.1.5INTEGERread-onlycurrent
pduFrequency
OBJECT-TYPE
Frequency of PDU.
1.3.6.1.4.1.10456.3.3.4.1.6INTEGERread-onlycurrent
pduCurrent
OBJECT-TYPE
Total Current of PDU(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.7INTEGERread-onlycurrent
pduPowerLoad
OBJECT-TYPE
Actual value of power in the PDU.
1.3.6.1.4.1.10456.3.3.4.1.8INTEGERread-onlycurrent
pduPowerFactor
OBJECT-TYPE
Actual value of power factor in the PDU.
1.3.6.1.4.1.10456.3.3.4.1.9INTEGERread-onlycurrent
pduPowerEnergy
OBJECT-TYPE
Actual value of power in the PDU.
1.3.6.1.4.1.10456.3.3.4.1.10INTEGERread-onlycurrent
pduOverload
OBJECT-TYPE
Overload of PDU(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.11INTEGERread-writecurrent
pduHighWarning
OBJECT-TYPE
High Warning of PDU(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.12INTEGERread-writecurrent
pduLowWarning
OBJECT-TYPE
High Warning of PDU(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.13INTEGERread-writecurrent
pduBranch
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.14INTEGERread-onlycurrent
pduBranch1Current
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.15INTEGERread-onlycurrent
pduBranch1Overload
OBJECT-TYPE
Overload of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.16INTEGERread-writecurrent
pduBranch1HighWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.17INTEGERread-writecurrent
pduBranch1LowWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.18INTEGERread-writecurrent
pduBranch2Current
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.19INTEGERread-onlycurrent
pduBranch2Overload
OBJECT-TYPE
Overload of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.20INTEGERread-writecurrent
pduBranch2HighWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.21INTEGERread-writecurrent
pduBranch2LowWarning
OBJECT-TYPE
Average Current of Input Feed(In tenths of amps, divide by 10 for value in amps).
1.3.6.1.4.1.10456.3.3.4.1.22INTEGERread-writecurrent
inbuiltTemperatureTable
OBJECT-TYPE
The table of Inbuilt Temperature Sensor.
1.3.6.1.4.1.10456.3.3.5not-accessiblecurrent
inbuiltTemperatureEntry
OBJECT-TYPE
Row definition for Inbuilt Temperature Sensor table.
1.3.6.1.4.1.10456.3.3.5.1not-accessiblecurrent
inbuiltTemperatureIndex
OBJECT-TYPE
Index for the Inbuilt Temperature Sensor table.
1.3.6.1.4.1.10456.3.3.5.1.1INTEGER (0..8)read-onlycurrent
inbuiltTemperatureStatus
OBJECT-TYPE
Inbuilt Temperature Sensor Connect Status.
1.3.6.1.4.1.10456.3.3.5.1.2INTEGER {no(0), yes(1)}read-onlycurrent
inbuiltTemperature
OBJECT-TYPE
Detected Temperature from Inbuilt Temperature Sensor.
1.3.6.1.4.1.10456.3.3.5.1.3INTEGERread-onlycurrent
inbuiltTemperatureHighWarning
OBJECT-TYPE
High Warning Temperature from Inbuilt Temperature Sensor.
1.3.6.1.4.1.10456.3.3.5.1.4INTEGERread-writecurrent
inbuiltTemperatureLowWarning
OBJECT-TYPE
Low Warning Temperature from Inbuilt Temperature Sensor.
1.3.6.1.4.1.10456.3.3.5.1.5INTEGERread-writecurrent
extendTemperatureTable
OBJECT-TYPE
The table of Extend Temperature Sensor.
1.3.6.1.4.1.10456.3.3.6not-accessiblecurrent
extendTemperatureEntry
OBJECT-TYPE
Row definition for Extend Temperature Sensor table.
1.3.6.1.4.1.10456.3.3.6.1not-accessiblecurrent
extendTemperatureIndex
OBJECT-TYPE
Index for the Extend Temperature Sensor table.
1.3.6.1.4.1.10456.3.3.6.1.1INTEGER (0..8)read-onlycurrent
extendTemperatureDeviceId
OBJECT-TYPE
Extend Temperature Monitor Status.
1.3.6.1.4.1.10456.3.3.6.1.2INTEGERread-onlycurrent
extendTemperaturePort
OBJECT-TYPE
Extend Temperature Monitor Status.
1.3.6.1.4.1.10456.3.3.6.1.3INTEGERread-onlycurrent
extendTemperatureMonitor
OBJECT-TYPE
Extend Temperature Monitor Status.
1.3.6.1.4.1.10456.3.3.6.1.4INTEGER {no(0), yes(1)}read-onlycurrent
extendTemperatureStatus
OBJECT-TYPE
Extend Temperature Sensor Connect Status.
1.3.6.1.4.1.10456.3.3.6.1.5INTEGER {no(0), yes(1)}read-onlycurrent
extendTemperature
OBJECT-TYPE
Detected Temperature from Inbuilt Temperature Sensor.
1.3.6.1.4.1.10456.3.3.6.1.6INTEGERread-onlycurrent
extendTemperatureHighWarning
OBJECT-TYPE
High Warning Temperature from Extend Temperature Sensor.
1.3.6.1.4.1.10456.3.3.6.1.7INTEGERread-writecurrent
extendTemperatureLowWarning
OBJECT-TYPE
Low Warning Temperature from Extend Temperature Sensor.
1.3.6.1.4.1.10456.3.3.6.1.8INTEGERread-writecurrent
extendRHTable
OBJECT-TYPE
The table of Extend RH Sensor.
1.3.6.1.4.1.10456.3.3.7not-accessiblecurrent
extendRHEntry
OBJECT-TYPE
Row definition for Extend RH table.
1.3.6.1.4.1.10456.3.3.7.1not-accessiblecurrent
extendRHIndex
OBJECT-TYPE
Index for the Extend RH Sensor table.
1.3.6.1.4.1.10456.3.3.7.1.1INTEGER (0..8)read-onlycurrent
extendRHDeviceId
OBJECT-TYPE
Index for the Extend RH Sensor table.
1.3.6.1.4.1.10456.3.3.7.1.2INTEGER (0..8)read-onlycurrent
extendRHPort
OBJECT-TYPE
Index for the Extend RH Sensor table.
1.3.6.1.4.1.10456.3.3.7.1.3INTEGER (0..8)read-onlycurrent
extendRHMonitor
OBJECT-TYPE
Extend RH Monitor Status.
1.3.6.1.4.1.10456.3.3.7.1.4INTEGER {no(0), yes(1)}read-onlycurrent
extendRHStatus
OBJECT-TYPE
Extend RH Sensor Connect Status.
1.3.6.1.4.1.10456.3.3.7.1.5INTEGER {no(0), yes(1)}read-onlycurrent
extendRH
OBJECT-TYPE
Detected RH from Inbuilt Temperature Sensor.
1.3.6.1.4.1.10456.3.3.7.1.6INTEGERread-onlycurrent
extendRHHighWarning
OBJECT-TYPE
High Warning RH from Extend Temperature Sensor.
1.3.6.1.4.1.10456.3.3.7.1.7INTEGERread-writecurrent
extendRHLowWarning
OBJECT-TYPE
Low Warning RH from Extend Temperature Sensor.
1.3.6.1.4.1.10456.3.3.7.1.8INTEGERread-writecurrent
inputTable
OBJECT-TYPE
The table of Input.
1.3.6.1.4.1.10456.3.3.8not-accessiblecurrent
inputEntry
OBJECT-TYPE
Row definition for Input table.
1.3.6.1.4.1.10456.3.3.8.1not-accessiblecurrent
inputIndex
OBJECT-TYPE
Index for Input table.
1.3.6.1.4.1.10456.3.3.8.1.1INTEGER (1)read-onlycurrent
inputStatus
OBJECT-TYPE
This OID is provided for Input Status. '0' NORMAL. '1' WARNING. '2' TIMEOUT.
1.3.6.1.4.1.10456.3.3.8.1.2INTEGERread-onlycurrent
inputState
OBJECT-TYPE
This OID is provided for Input Default. '0' NORMAL_CLOSE. '1' NORMAL_OPEN.
1.3.6.1.4.1.10456.3.3.8.1.3INTEGERread-writecurrent
inputTimeout
OBJECT-TYPE
TimeOut of Input Status.
1.3.6.1.4.1.10456.3.3.8.1.4INTEGERread-writecurrent
inputDefault
OBJECT-TYPE
This OID is provided for Input Default. '0' NORMAL_CLOSE. '1' NORMAL_OPEN.
1.3.6.1.4.1.10456.3.3.8.1.5INTEGERread-writecurrent
inputDetectTime
OBJECT-TYPE
Detect the nearest Changed Time of Input Status.
1.3.6.1.4.1.10456.3.3.8.1.6DisplayStringread-onlycurrent
rfidReader
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.3.9
rfidCardNum
OBJECT-TYPE
RFID Card Number.
1.3.6.1.4.1.10456.3.3.9.1DisplayStringread-onlycurrent
rfidDetectTime
OBJECT-TYPE
The Nearest Time to detect RFID Card.
1.3.6.1.4.1.10456.3.3.9.2DisplayStringread-onlycurrent
uPS
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.3.10
uPSModel
OBJECT-TYPE
UPS Model.
1.3.6.1.4.1.10456.3.3.10.1DisplayStringread-onlycurrent
uPSConnectStatus
OBJECT-TYPE
UPS Connect Status.
1.3.6.1.4.1.10456.3.3.10.2INTEGERread-onlycurrent
uPSFirmware
OBJECT-TYPE
UPS Firmware.
1.3.6.1.4.1.10456.3.3.10.3DisplayStringread-onlycurrent
uPSSerial
OBJECT-TYPE
UPS Serial.
1.3.6.1.4.1.10456.3.3.10.4DisplayStringread-onlycurrent
uPSTemperature
OBJECT-TYPE
UPS Temperature.
1.3.6.1.4.1.10456.3.3.10.5INTEGERread-onlycurrent
uPSInputVoltage
OBJECT-TYPE
UPS Input Voltage.
1.3.6.1.4.1.10456.3.3.10.6INTEGERread-onlycurrent
uPSOutputOnBattery
OBJECT-TYPE
UPS Output On Battery.
1.3.6.1.4.1.10456.3.3.10.7INTEGERread-onlycurrent
uPSOutputVoltage
OBJECT-TYPE
UPS Output Voltage.
1.3.6.1.4.1.10456.3.3.10.8INTEGERread-onlycurrent
uPSOutputFrequency
OBJECT-TYPE
UPS Output Voltage.
1.3.6.1.4.1.10456.3.3.10.9INTEGERread-onlycurrent
uPSOutputCurrent
OBJECT-TYPE
UPS Output Current.
1.3.6.1.4.1.10456.3.3.10.10INTEGERread-onlycurrent
uPSOutputLoad
OBJECT-TYPE
UPS Output Load.
1.3.6.1.4.1.10456.3.3.10.11INTEGERread-onlycurrent
uPSOutputOverload
OBJECT-TYPE
UPS Output Overload.
1.3.6.1.4.1.10456.3.3.10.12INTEGERread-onlycurrent
uPSBatteryDate
OBJECT-TYPE
UPS Battery Date.
1.3.6.1.4.1.10456.3.3.10.13DisplayStringread-onlycurrent
uPSBatteryVoltage
OBJECT-TYPE
UPS Battery Voltage.
1.3.6.1.4.1.10456.3.3.10.14INTEGERread-onlycurrent
uPSBatteryLevel
OBJECT-TYPE
UPS Battery Level.
1.3.6.1.4.1.10456.3.3.10.15INTEGERread-onlycurrent
uPSBatteryRunTime
OBJECT-TYPE
UPS Battery RunTime.
1.3.6.1.4.1.10456.3.3.10.16INTEGERread-onlycurrent
uPSBatteryLow
OBJECT-TYPE
UPS Battery Low.
1.3.6.1.4.1.10456.3.3.10.17INTEGERread-onlycurrent
uPSBatteryReplace
OBJECT-TYPE
UPS Battery Need Replace.
1.3.6.1.4.1.10456.3.3.10.18INTEGERread-onlycurrent
uPSUARTId
OBJECT-TYPE
UPS UART Id.
1.3.6.1.4.1.10456.3.3.10.19INTEGERread-onlycurrent
micDetec
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.3.11
micDetectTimes
OBJECT-TYPE
MIC Detect Times.
1.3.6.1.4.1.10456.3.3.11.1INTEGERread-onlycurrent
micDetectPeriod
OBJECT-TYPE
MIC Detect Period.
1.3.6.1.4.1.10456.3.3.11.2INTEGERread-onlycurrent
micLastDetectTime
OBJECT-TYPE
MIC Detect Detect Time.
1.3.6.1.4.1.10456.3.3.11.3DisplayStringread-onlycurrent
vibrationDetec
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.3.12
vibrationDetectTimes
OBJECT-TYPE
Vibration Detect Times.
1.3.6.1.4.1.10456.3.3.12.1INTEGERread-onlycurrent
vibrationDetectPeriod
OBJECT-TYPE
Vibration Detect Period.
1.3.6.1.4.1.10456.3.3.12.2INTEGERread-onlycurrent
vibrationLastDetectTime
OBJECT-TYPE
Vibration Detect Detect Time.
1.3.6.1.4.1.10456.3.3.12.3DisplayStringread-onlycurrent
dataLogTable
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.4
inFeedDataList
OBJECT-TYPE
Input Feed Data List.
1.3.6.1.4.1.10456.3.4.1DisplayStringread-onlycurrent
outDataList
OBJECT-TYPE
Outlet Data List.
1.3.6.1.4.1.10456.3.4.2DisplayStringread-onlycurrent
pduDataList
OBJECT-TYPE
PDU Data List.
1.3.6.1.4.1.10456.3.4.3DisplayStringread-onlycurrent
smartTraps
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.100
trap
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.100.1
arg
OBJECT-IDENTITY
1.3.6.1.4.1.10456.3.100.2
trapArg1
OBJECT-TYPE
Indicate the Trap Arg1.
1.3.6.1.4.1.10456.3.100.2.1INTEGERread-onlycurrent
trapArg2
OBJECT-TYPE
Indicate the Trap Arg2.
1.3.6.1.4.1.10456.3.100.2.2INTEGERread-onlycurrent
trapArg3
OBJECT-TYPE
Indicate the Trap Arg3.
1.3.6.1.4.1.10456.3.100.2.3INTEGERread-onlycurrent
trapArg4
OBJECT-TYPE
Indicate the Trap Arg4.
1.3.6.1.4.1.10456.3.100.2.4INTEGERread-onlycurrent
trapArg5
OBJECT-TYPE
Indicate the Trap Arg5.
1.3.6.1.4.1.10456.3.100.2.5INTEGERread-onlycurrent
trapArg6
OBJECT-TYPE
Indicate the Trap Arg6.
1.3.6.1.4.1.10456.3.100.2.6INTEGERread-onlycurrent
trapArg7
OBJECT-TYPE
Indicate the Trap Arg7.
1.3.6.1.4.1.10456.3.100.2.7INTEGERread-onlycurrent
trapArg8
OBJECT-TYPE
Indicate the Trap Arg8.
1.3.6.1.4.1.10456.3.100.2.8INTEGERread-onlycurrent
trapArg9
OBJECT-TYPE
Indicate the Trap Arg9.
1.3.6.1.4.1.10456.3.100.2.9INTEGERread-onlycurrent

Notifications

NameOIDStatus
testTrap
NOTIFICATION-TYPE
testData
1.3.6.1.4.1.10456.3.100.1.1current
inFeedOverloadTrap
NOTIFICATION-TYPE
deviceIndex, inFeedIndex, inFeedStatus, inFeedCurrent, inFeedOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.101current
inFeedHighCurrentTrap
NOTIFICATION-TYPE
deviceIndex, inFeedIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.102current
inFeedLowCurrentTrap
NOTIFICATION-TYPE
deviceIndex, inFeedIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.103current
inFeedBranchOverloadTrap
NOTIFICATION-TYPE
inFeedIndex, BranchIndex, inFeedStatus, inFeedCurrent, inFeedOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.104current
inFeedBranchHighCurrentTrap
NOTIFICATION-TYPE
inFeedIndex, BranchIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.105current
inFeedBranchLowCurrentTrap
NOTIFICATION-TYPE
inFeedIndex, BranchIndex, inFeedStatus, inFeedCurrent, inFeedHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.106current
outWebOperationTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.201current
outPanelOperationTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.202current
outAPIOperationTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.203current
outScheduleTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.211current
outScheduleErrorTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.212current
outPingTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.221current
outPingRebootTrap
NOTIFICATION-TYPE
Outlet on/off change event. If enabled, this trap is sent when the outStatus changes from any 'on' state ('on', 'onWait', 'onError', or 'onFuse') to any 'off' state ('off', 'offWait', 'offError', or 'offFuse'), and vice-versa.
1.3.6.1.4.1.10456.3.100.1.222current
outOverloadTrap
NOTIFICATION-TYPE
deviceIndex, outIndex, outCurrentStatus, outCurrent, outHighWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.231current
outHighCurrentTrap
NOTIFICATION-TYPE
deviceIndex, outIndex, outCurrentStatus, outCurrent, outHighWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.232current
outLowCurrentTrap
NOTIFICATION-TYPE
deviceIndex, outIndex, outCurrentStatus, outCurrent, outLowWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.233current
outConditionCtrlTrap
NOTIFICATION-TYPE
deviceIndex, outIndex, outCurrentStatus, outCurrent, outLowWarning Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.241current
outUPSACFaultOffTrap
NOTIFICATION-TYPE
deviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.311current
outUPSBatteryLevelOffTrap
NOTIFICATION-TYPE
deviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.312current
outUPSBatteryLowOffTrap
NOTIFICATION-TYPE
deviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.313current
outUPSACRecoveryOnTrap
NOTIFICATION-TYPE
deviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.314current
outUPSBatteryLevelOnTrap
NOTIFICATION-TYPE
deviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.315current
outUPSBatteryLowRecoveryOnTrap
NOTIFICATION-TYPE
deviceIndex, value Outlet load event. If enabled, this trap is sent when the outLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the outLoadStatus remains in an error state. If the outLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error outLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.316current
pduConnectTrap
NOTIFICATION-TYPE
PDUIndex, PDUConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.401current
pduOverloadTrap
NOTIFICATION-TYPE
deviceIndex, PDUIndex, PDUStatus, PDUCurrent, PDUOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.402current
pduHighCurrentTrap
NOTIFICATION-TYPE
deviceIndex, PDUIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.403current
pduLowCurrentTrap
NOTIFICATION-TYPE
deviceIndex, PDUIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.404current
pduBranchOverloadTrap
NOTIFICATION-TYPE
PDUIndex, BranchIndex, PDUStatus, PDUCurrent, PDUOverload Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.405current
pduBranchHighCurrentTrap
NOTIFICATION-TYPE
PDUIndex, BranchIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.406current
pduBranchLowCurrentTrap
NOTIFICATION-TYPE
PDUIndex, BranchIndex, PDUStatus, PDUCurrent, PDUHighWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.407current
inbuiltTemperatureHighTrap
NOTIFICATION-TYPE
InTempId, InTempStatus, InTempTemperature, InTempTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.501current
inbuiltTemperatureLowTrap
NOTIFICATION-TYPE
InTempId, InTempStatus, InTempTemperature, InTempTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.502current
envConnectTrap
NOTIFICATION-TYPE
deviceIndex, ENVIndex, ENVConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.511current
envTemperatureConnectTrap
NOTIFICATION-TYPE
deviceIndex, ENVIndex, ENVConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.512current
envTemperatureHighTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.513current
envTemperatureLowTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.514current
envRHConnectTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvRH, EnvRHWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.515current
envRHHighTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvRH, EnvRHWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.516current
envRHLowTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvRH, EnvRHWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.517current
inputTimeOutTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.601current
inputTrap
NOTIFICATION-TYPE
deviceIndex, EnvId, EnvStatus, EnvTemperature, EnvTemperatureWarning Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.602current
upsConnectTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.701current
upsOnBatteryTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.702current
upsOverloadTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.703current
upsBatteryLowTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.704current
upsBatteryReplace
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.705current
daisyChainConnectTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.801current
micDetectOccurTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.901current
vibrationDetectOccurTrap
NOTIFICATION-TYPE
Model, ConnectStatus Input feed load event. If enabled, this trap is sent when the infeedLoadStatus indicates an error state ('loadLow', 'loadHigh', 'overLoad', 'readError', or 'noComm'). This trap is repeated periodically while the infeedLoadStatus remains in an error state. If the infeedLoadStatus returns to a non-error state ('normal' or 'notOn'), this trap is sent once more with the non-error infeedLoadStatus, and then stops being repeated.
1.3.6.1.4.1.10456.3.100.1.902current