MIBs Depot

DECNET-PHIV-MIB

Registered at
1.3.6.1.2.1.18
Namespace
standard
Source file
DECNET-PHIV-MIB
Digest
sha256:3e988487f7ff228a0d232bce1aab328ad8fed747c50dfb5ddd43997dd97b4a41

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, mib-2
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DECNET-PHIV-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
InterfaceIndex
type
PhivAddr
type
PhivCounter
type

Objects

NameOIDSyntaxAccessStatus
phiv
OBJECT-IDENTITY
1.3.6.1.2.1.18
phivSystem
OBJECT-IDENTITY
1.3.6.1.2.1.18.1
phivSystemState
OBJECT-TYPE
This represents the operational state of the executor node. The possible states are: ON Allows logical links. OFF Allows no new links, terminates existing links, and stops routing traffic through. SHUT Allows no new logical links, does not destroy existing logical links, and goes to the OFF state when all logical links are gone. RESTRICTED Allows no new incoming logical links from other nodes. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155).
1.3.6.1.2.1.18.1.1INTEGER {on(1), off(2), shut(3), restricted(4)}read-writemandatory
phivExecIdent
OBJECT-TYPE
This is a text string that describes the executor node (for example, 'Research Lab'). The string is up to 32 characters of any type.
1.3.6.1.2.1.18.1.2DisplayString (SIZE(0..32))read-writemandatory
phivManagement
OBJECT-IDENTITY
1.3.6.1.2.1.18.2
phivMgmtMgmtVers
OBJECT-TYPE
This is the read-only Network Management Version, consisting of the version number, the Engineering Change Order (ECO) number, and the user ECO number (for example, 3.0.0). This parameter applies to the executor node only.
1.3.6.1.2.1.18.2.1DisplayString (SIZE(0..255))read-onlymandatory
session
OBJECT-IDENTITY
1.3.6.1.2.1.18.3
phivSessionSystemName
OBJECT-TYPE
Name to be associated with the node identification. Only one name can be assigned to a node address or a circuit identification. No name should be used more than once in a DECnet network. Node-name is one to six upper case alphanumeric characters with at least one alpha character. A length of 0 indicates no name.
1.3.6.1.2.1.18.3.1DisplayString (SIZE(0..6))read-onlymandatory
phivSessionInTimer
OBJECT-TYPE
This value represents the maximum duration between the time a connect is received for a process at the executor node and the time that process accepts or rejects it. If the connect is not accepted or rejected by the user within the number of seconds specified, Session Control rejects it for the user. A value of 0 indicates no timer is running.
1.3.6.1.2.1.18.3.2INTEGER (0..65535)read-writemandatory
phivSessionOutTimer
OBJECT-TYPE
This value represents the duration between the time the executor requests a connect and the time that connect is acknowledged by the destination node. If the connect is not acknowledged within the number of seconds specified, Session Control returns an error. A value of 0 indicates no timer is running.
1.3.6.1.2.1.18.3.3INTEGER (0..65535)read-writemandatory
end
OBJECT-IDENTITY
1.3.6.1.2.1.18.4
phivEndRemoteTable
OBJECT-TYPE
Information about the state of sessions between the node under study and the nodes found in the table.
1.3.6.1.2.1.18.4.1not-accessiblemandatory
phivEndRemoteEntry
OBJECT-TYPE
Information about a particular remote node as seen from the end communication layer.
1.3.6.1.2.1.18.4.1.1not-accessiblemandatory
phivEndRemoteHostNodeID
OBJECT-TYPE
This value is the address of the remote node to be evaluated.
1.3.6.1.2.1.18.4.1.1.1PhivAddrread-onlymandatory
phivEndRemoteState
OBJECT-TYPE
This represents the operational state of the remote node being evaluated. The possible states are: ON Allows logical links. OFF Allows no new links, terminates existing links, and stops routing traffic through. SHUT Allows no new logical links, does not destroy existing logical links, and goes to the OFF state when all logical links are gone. RESTRICTED Allows no new incoming logical links from other nodes. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155.
1.3.6.1.2.1.18.4.1.1.2INTEGER {on(1), off(2), shut(3), restricted(4)}read-writemandatory
phivEndCircuitIndex
OBJECT-TYPE
A unique index value for each known circuit used to communicate with the remote node. This is the same value as phivCircuitIndex.
1.3.6.1.2.1.18.4.1.1.3INTEGER (1..65535)read-onlymandatory
phivEndDelay
OBJECT-TYPE
This read-only parameter is the average round trip delay in seconds to the destination node. This parameter is kept on a remote node basis.
1.3.6.1.2.1.18.4.1.1.5INTEGER (0..65535)read-onlymandatory
phivEndCountTable
OBJECT-TYPE
Information about the counters associated with each end system that is known to the entity. These counters reflect totals from the perspective of the executor node.
1.3.6.1.2.1.18.4.2not-accessiblemandatory
phivEndCountEntry
OBJECT-TYPE
Information about a particular session between two end systems.
1.3.6.1.2.1.18.4.2.1not-accessiblemandatory
phivEndCountHostNodeID
OBJECT-TYPE
This value is the address of the remote node to be evaluated.
1.3.6.1.2.1.18.4.2.1.1PhivAddrread-onlymandatory
phivEndCountSecsLastZeroed
OBJECT-TYPE
This value is the number of seconds that have elapsed since the counters for the node in this table row were last set to zero. This counter is located in the network management layer, but is returned with the end system information which follows.
1.3.6.1.2.1.18.4.2.1.2PhivCounter (0..65535)read-onlymandatory
phivEndCountUsrBytesRec
OBJECT-TYPE
Number of user bytes received from the target host.
1.3.6.1.2.1.18.4.2.1.3PhivCounter (0..2147483647)read-onlymandatory
phivEndCountUsrBytesSent
OBJECT-TYPE
Number of user bytes sent to the target host.
1.3.6.1.2.1.18.4.2.1.4PhivCounter (0..2147483647)read-onlymandatory
phivEndUCountUsrMessRec
OBJECT-TYPE
Number of user messages received from the target host.
1.3.6.1.2.1.18.4.2.1.5PhivCounter (0..2147483647)read-onlymandatory
phivEndCountUsrMessSent
OBJECT-TYPE
Number of user messages sent to the target host.
1.3.6.1.2.1.18.4.2.1.6PhivCounter (0..2147483647)read-onlymandatory
phivEndCountTotalBytesRec
OBJECT-TYPE
Number of bytes received from the target host.
1.3.6.1.2.1.18.4.2.1.7PhivCounter (0..2147483647)read-onlymandatory
phivEndCountTotalBytesSent
OBJECT-TYPE
Number of bytes sent to the target host.
1.3.6.1.2.1.18.4.2.1.8PhivCounter (0..2147483647)read-onlymandatory
phivEndCountTotalMessRec
OBJECT-TYPE
Number of messages received from the target host.
1.3.6.1.2.1.18.4.2.1.9PhivCounter (0..2147483647)read-onlymandatory
phivEndCountTotalMessSent
OBJECT-TYPE
Number of messages sent to the target host.
1.3.6.1.2.1.18.4.2.1.10PhivCounter (0..2147483647)read-onlymandatory
phivEndCountConnectsRecd
OBJECT-TYPE
Number of connects received from the target host.
1.3.6.1.2.1.18.4.2.1.11PhivCounter (0..65535)read-onlymandatory
phivEndCountConnectsSent
OBJECT-TYPE
Number of connects sent to the target host.
1.3.6.1.2.1.18.4.2.1.12PhivCounter (0..65535)read-onlymandatory
phivEndCountReponseTimeouts
OBJECT-TYPE
Number of response timeouts.
1.3.6.1.2.1.18.4.2.1.13PhivCounter (0..65535)read-onlymandatory
phivEndCountRecdConnectResErrs
OBJECT-TYPE
Number of received connect resource errors.
1.3.6.1.2.1.18.4.2.1.14PhivCounter (0..65535)read-onlymandatory
phivEndNSPVers
OBJECT-TYPE
This read-only parameter represents the version number of the node End Communication S/W. The format is version number, ECO, and user ECO, e.g., 4.1.0
1.3.6.1.2.1.18.4.4DisplayString (SIZE(0..255))read-onlymandatory
phivEndRetransmitFactor
OBJECT-TYPE
This value represents the maximum number of times the source End Communication at the executor node will restart the retransmission timer when it expires. If the number is exceeded, Session Control disconnects the logical link for the user.
1.3.6.1.2.1.18.4.5INTEGER (1..65535)read-writemandatory
phivEndDelayFact
OBJECT-TYPE
This is the number by which to multiply one sixteenth of the estimated round trip delay to a node to set the retransmission timer to that node.
1.3.6.1.2.1.18.4.6INTEGER (1..255)read-writemandatory
phivEndDelayWeight
OBJECT-TYPE
This number represents the weight to apply to a current round trip delay estimate to a remote node when updating the estimated round trip delay to a node. On some systems the number must be 1 less than a power of 2 for computational efficiency.
1.3.6.1.2.1.18.4.7INTEGER (1..255)read-writemandatory
phivEndInactivityTimer
OBJECT-TYPE
This value represents the maximum duration of inactivity (no data in either direction) on a logical link before the node checks to see if the logical link still works. If no activity occurs within the minimum number of seconds, End Communication generates artificial traffic to test the link (End Communication specification).
1.3.6.1.2.1.18.4.8INTEGER (1..65535)read-writemandatory
phivEndCountZeroCount
OBJECT-TYPE
When this value is set to 2, all of the counters in the End System Counter Table are set to zero.
1.3.6.1.2.1.18.4.9INTEGER {other(1), reset(2)}read-writemandatory
phivEndMaxLinksActive
OBJECT-TYPE
This value represents the high water mark for the number of links that were active at any one time.
1.3.6.1.2.1.18.4.10PhivCounter (0..65535)read-writemandatory
routing
OBJECT-IDENTITY
1.3.6.1.2.1.18.5
phivRouteBroadcastRouteTimer
OBJECT-TYPE
This value determines the maximum time in seconds allowed between Routing updates on Ethernet circuits. When this timer expired before a routing update occurs, a routing update is forced. With a standard calculation, Routing also uses this timer to enforce a minimum delay between routing updates.
1.3.6.1.2.1.18.5.1INTEGER (1..65535)read-writemandatory
phivRouteBuffSize
OBJECT-TYPE
This parameter value determines the maximum size of a Routing message. It therefore determines the maximum size message that can be forwarded. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the parameter definition in Phase III, which included the Routing overhead.) It does not include Routing or Data link overhead (except for the constant value of 6). There is one buffer size for all circuits. NOTE: The BUFFER SIZE defines the maximum size messages that the Routing layer can forward. The SEGMENT BUFFER SIZE (defined below) defines the maximum size messages that the End Communication layer can transmit or receive. The SEGMENT BUFFER SIZE is always less than or equal to the BUFFER SIZE. Normally the two parameters will be equal. They may be different to allow the network manager to alter buffer sizes on all nodes without interruption of service. They both include an extra 6 bytes for compatibility with Phase III.
1.3.6.1.2.1.18.5.2INTEGER (1..65535)read-writemandatory
phivRouteRoutingVers
OBJECT-TYPE
This read-only parameter identifies the executor node's Routing version number. The format is version number, ECO, and user ECO, e.g., 4.1.0
1.3.6.1.2.1.18.5.3DisplayString (SIZE(0..255))read-onlymandatory
phivRouteMaxAddr
OBJECT-TYPE
This value represents the largest node number and, therefore, number of nodes that can be known about by the executor node's home area.
1.3.6.1.2.1.18.5.4INTEGER (1..1023)read-writemandatory
phivRouteMaxBdcastNonRouters
OBJECT-TYPE
This value represents the maximum total number of nonrouters the executor node can have on its Ethernet circuits.
1.3.6.1.2.1.18.5.5INTEGER (0..65535)read-writemandatory
phivRouteMaxBdcastRouters
OBJECT-TYPE
This value represents the maximum total number of routers the executor node can have on its Ethernet circuits.
1.3.6.1.2.1.18.5.6INTEGER (0..65535)read-writemandatory
phivRouteMaxBuffs
OBJECT-TYPE
This value represents the maximum number of transmit buffers that Routing may use for all circuits.
1.3.6.1.2.1.18.5.7INTEGER (1..65535)read-writemandatory
phivRouteMaxCircuits
OBJECT-TYPE
This value represents the maximum number of Routing circuits that the executor node can know about.
1.3.6.1.2.1.18.5.8INTEGER (1..65535)read-writemandatory
phivRouteMaxCost
OBJECT-TYPE
This value represents the maximum total path cost allowed from the executor to any node within an area. The path cost is the sum of the circuit costs along a path between two nodes. This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the cost of the least costly path to the other node is excessive. For correct operation, this parameter must not be less than the maximum path cost of the network.
1.3.6.1.2.1.18.5.9INTEGER (1..1022)read-writemandatory
phivRouteMaxHops
OBJECT-TYPE
This value represents the maximum number of routing hops allowable from the executor to any other reachable node within an area. (A hop is the logical distance over a circuit between two adjacent nodes.) This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the length of the shortest path between the two nodes is too long. For correct operation, this parameter must not be less than the network diameter. (The network diameter is the reachability distance between the two nodes of the network having the greatest reachability distance, where reachability distance is the length the shortest path between a given pair of nodes.)
1.3.6.1.2.1.18.5.10INTEGER (1..30)read-writemandatory
phivRouteMaxVisits
OBJECT-TYPE
This value represents the maximum number of nodes a message coming into the executor node can have visited. If the message is not for this node and the MAXIMUM VISITS number is exceeded, the message is discarded. The MAXIMUM VISITS parameter defines the point where the packet lifetime control algorithm discards a packet that has traversed too many nodes. For correct operation, this parameter must not be less than the maximum path length of the network. (The maximum path length is the routing distance between the two nodes of the network having the greatest routing distance, where routing distance is the length of the least costly path between a given pair of nodes.)
1.3.6.1.2.1.18.5.11INTEGER (1..63)read-writemandatory
phivRouteRoutingTimer
OBJECT-TYPE
This value determines the maximum time in seconds allowed between Routing updates on non-Ethernet circuits. When this timer expires before a routing update occurs, a routing update is forced.
1.3.6.1.2.1.18.5.12INTEGER (1..65535)read-writemandatory
phivRouteSegBuffSize
OBJECT-TYPE
This parameter value determines the maximum size of an end-to-end segment. The size is a decimal integer in the range 1-65535. This size is in bytes. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the BUFFER SIZE parameter definition.) It does not include Routing or Data link overhead (except for the constant value of 6).
1.3.6.1.2.1.18.5.13INTEGER (1..65535)read-writemandatory
phivRouteType
OBJECT-TYPE
This parameter indicates the type of the executor node. The node-type is one of the following: routing-III nonrouting-III routing-IV ronrouting-IV area A routing node has full routing capability. A nonrouting node contains a subset of the Routing routing modules. The III and IV indicate the DNA phase of the node. Nonrouting nodes can deliver and receive packets to and from any node, but cannot route packets from other nodes through to other nodes. An area node routes between areas. Refer to the Routing specification for details. For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The ROUTING-III and NONROUTING-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)
1.3.6.1.2.1.18.5.14INTEGER {routing-III(1), nonrouting-III(2), area(3), routing-IV(4), nonrouting-IV(5)}read-onlyobsolete
phivRouteCountAgedPktLoss
OBJECT-TYPE
Number of aged packet losses.
1.3.6.1.2.1.18.5.15PhivCounter (0..127)read-onlymandatory
phivRouteCountNodeUnrPktLoss
OBJECT-TYPE
Number of node unreachable packet losses.
1.3.6.1.2.1.18.5.16PhivCounter (0..65535)read-onlymandatory
phivRouteCountOutRngePktLoss
OBJECT-TYPE
Number of node out-of-range packet losses.
1.3.6.1.2.1.18.5.17PhivCounter (0..127)read-onlymandatory
phivRouteCountOverSzePktLoss
OBJECT-TYPE
Number of Oversized packet losses.
1.3.6.1.2.1.18.5.18PhivCounter (0..127)read-onlymandatory
phivRouteCountPacketFmtErr
OBJECT-TYPE
Number of packet format errors.
1.3.6.1.2.1.18.5.19PhivCounter (0..127)read-onlymandatory
phivRouteCountPtlRteUpdtLoss
OBJECT-TYPE
Number of partial routing update losses.
1.3.6.1.2.1.18.5.20PhivCounter (0..127)read-onlymandatory
phivRouteCountVerifReject
OBJECT-TYPE
Number of verification rejects.
1.3.6.1.2.1.18.5.21PhivCounter (0..127)read-onlymandatory
phivLevel1RouteTable
OBJECT-TYPE
Information about the currently known DECnet Phase IV Routes.
1.3.6.1.2.1.18.5.22not-accessiblemandatory
phivLevel1RouteEntry
OBJECT-TYPE
Information about the currently known DECnet Phase IV Routes.
1.3.6.1.2.1.18.5.22.1not-accessiblemandatory
phivLevel1RouteNodeAddr
OBJECT-TYPE
This value is the address of the node about which routing information is contained in this level 1 routing table.
1.3.6.1.2.1.18.5.22.1.1PhivAddrread-onlymandatory
phivLevel1RouteCircuitIndex
OBJECT-TYPE
A unique index value for each known circuit. This is the index to the circuit state table and is the same value as phivCircuitIndex.
1.3.6.1.2.1.18.5.22.1.2INTEGER (1..65535)read-onlymandatory
phivLevel1RouteCost
OBJECT-TYPE
This read-only parameter represents the total cost over the current path to the destination node. Cost is a positive integer value associated with using a circuit. Routing routes messages (data) along the path between two nodes with the smallest cost. COST is kept on a remote node basis.
1.3.6.1.2.1.18.5.22.1.3INTEGER (0..65535)read-onlymandatory
phivLevel1RouteHops
OBJECT-TYPE
This read-only parameter represents the number of hops over to a destination node. A hop is Routing value representing the logical distance between two nodes in a network. HOPS is kept on a remote node basis.
1.3.6.1.2.1.18.5.22.1.4INTEGER (0..127)read-onlymandatory
phivLevel1RouteNextNode
OBJECT-TYPE
This read-only value indicates the next node on the circuit used to get to the node under scrutiny (next hop).
1.3.6.1.2.1.18.5.22.1.5PhivAddrread-onlymandatory
phivRouteCountZeroCount
OBJECT-TYPE
When this value is set to 2, the following objects are set to Zero: phivRouteCountAgedPktLoss, phivRouteCountNodeUnrPktLoss, phivRouteCountOutRngePktLoss, phivRouteCountOverSzePktLoss, phivRouteCountPacketFmtErr, phivRouteCountPtlRteUpdtLoss, and phivRouteCountVerifReject.
1.3.6.1.2.1.18.5.23INTEGER {other(1), reset(2)}read-writemandatory
phivRouteSystemAddr
OBJECT-TYPE
DECnet Phase IV node address.
1.3.6.1.2.1.18.5.24PhivAddrread-onlyobsolete
phivRouteRoutingType
OBJECT-TYPE
This read-write parameter indicates the type of the executor node. The node-type is one of the following: routing-III nonrouting-III routing-IV ronrouting-IV area A routing node has full routing capability. A nonrouting node contains a subset of the Routing routing modules. The III and IV indicate the DNA phase of the node. Nonrouting nodes can deliver and receive packets to and from any node, but cannot route packets from other nodes through to other nodes. An area node routes between areas. Refer to the Routing specification for details. For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The ROUTING-III and NONROUTING-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)
1.3.6.1.2.1.18.5.25INTEGER {routing-III(1), nonrouting-III(2), area(3), routing-IV(4), nonrouting-IV(5)}read-writemandatory
phivRouteSystemAddress
OBJECT-TYPE
DECnet Phase IV node address.
1.3.6.1.2.1.18.5.26PhivAddrread-writemandatory
circuit
OBJECT-IDENTITY
1.3.6.1.2.1.18.6
phivCircuitParametersTable
OBJECT-TYPE
Information about the parameters associated with all circuits currently known.
1.3.6.1.2.1.18.6.1not-accessiblemandatory
phivCircuitParametersEntry
OBJECT-TYPE
Parameters information about all circuits currently known.
1.3.6.1.2.1.18.6.1.1not-accessiblemandatory
phivCircuitIndex
OBJECT-TYPE
A unique index value for each known circuit.
1.3.6.1.2.1.18.6.1.1.1INTEGER (1..65535)read-onlymandatory
phivCircuitLineIndex
OBJECT-TYPE
The line on which this circuit is active. This is the same as the ifIndex.
1.3.6.1.2.1.18.6.1.1.2InterfaceIndexread-onlymandatory
phivCircuitCommonState
OBJECT-TYPE
This value represents the circuit's Network Management operational state. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155.
1.3.6.1.2.1.18.6.1.1.3INTEGER {on(1), off(2), service(3), cleared(4)}read-writemandatory
phivCircuitCommonSubState
OBJECT-TYPE
This value represents the circuit's Network Management operational and service substate. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155.
1.3.6.1.2.1.18.6.1.1.4INTEGER {starting(1), reflecting(2), looping(3), loading(4), dumping(5), triggering(6), autoservice(7), autoloading(8), autodumping(9), autotriggering(10), synchronizing(11), failed(12), running(13)}read-onlymandatory
phivCircuitCommonName
OBJECT-TYPE
The name of the circuit entry in the table, for example, SVA-0 or in a level 2 router ASYNC-8 or ETHER-1).
1.3.6.1.2.1.18.6.1.1.5DisplayString (SIZE(0..16))read-onlymandatory
phivCircuitExecRecallTimer
OBJECT-TYPE
This parameter represents the minimum number of seconds to wait before restarting the circuit. A value of 0 indicates not timer is running.
1.3.6.1.2.1.18.6.1.1.6INTEGER (0..65535)read-writemandatory
phivCircuitCommonType
OBJECT-TYPE
Represents the type of the circuit. For X.25 circuits, the value must be set to X25. For DDCMP and Ethernet circuits it is read only and is the same value as the protocol of the associated line. NOTE: Values 1 - 5 are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155.
1.3.6.1.2.1.18.6.1.1.7INTEGER {ddcmp-point(1), ddcmp-control(2), ddcmp-tributary(3), x25(4), ddcmp-dmc(5), ethernet(6), ci(7), qp2-dte20(8), bisync(9), other(14), fddi(15)}read-onlymandatory
phivCircuitService
OBJECT-TYPE
This value indicates whether or not Network Management allows service operations on a circuit. The values for service-control are as follows: ENABLED SERVICE state and/or service functions are allowed. DISABLED SERVICE state and/or service functions are not allowed. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155.
1.3.6.1.2.1.18.6.1.1.8INTEGER {enabled(1), disabled(2)}read-writemandatory
phivCircuitExecCost
OBJECT-TYPE
This value represents the routing cost of the circuit. Routing sends messages along the path between two nodes having the smallest cost.
1.3.6.1.2.1.18.6.1.1.9INTEGER (1..25)read-writemandatory
phivCircuitExecHelloTimer
OBJECT-TYPE
This value determines the frequency of Routing Hello messages sent to the adjacent node on the circuit.
1.3.6.1.2.1.18.6.1.1.10INTEGER (1..8191)read-writemandatory
phivCircuitCountTable
OBJECT-TYPE
Information about the counters associated with all circuits currently known.
1.3.6.1.2.1.18.6.2not-accessiblemandatory
phivCircuitCountEntry
OBJECT-TYPE
Counter information about all circuits currently known
1.3.6.1.2.1.18.6.2.1not-accessiblemandatory
phivCircuitCountSecLastZeroed
OBJECT-TYPE
Number of seconds since the circuit counters for this circuit were last zeroed.
1.3.6.1.2.1.18.6.2.1.1PhivCounter (0..65535)read-onlymandatory
phivCircuitCountTermPacketsRecd
OBJECT-TYPE
Number of terminating packets received on this circuit.
1.3.6.1.2.1.18.6.2.1.2PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountOriginPackSent
OBJECT-TYPE
Number of originating packets sent on this circuit.
1.3.6.1.2.1.18.6.2.1.3PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountTermCongLoss
OBJECT-TYPE
Number of terminating congestion losses on this circuit.
1.3.6.1.2.1.18.6.2.1.4PhivCounter (0..65535)read-onlymandatory
phivCircuitCountCorruptLoss
OBJECT-TYPE
Number of corruption losses on this circuit.
1.3.6.1.2.1.18.6.2.1.5PhivCounter (0..255)read-onlymandatory
phivCircuitCountTransitPksRecd
OBJECT-TYPE
Number of Transit packets received on this circuit.
1.3.6.1.2.1.18.6.2.1.6PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountTransitPkSent
OBJECT-TYPE
Number of transit packets sent on this circuit.
1.3.6.1.2.1.18.6.2.1.7PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountTransitCongestLoss
OBJECT-TYPE
Number of transit congestion losses on this circuit.
1.3.6.1.2.1.18.6.2.1.8PhivCounter (0..65535)read-onlymandatory
phivCircuitCountCircuitDown
OBJECT-TYPE
Number of circuit downs on this circuit.
1.3.6.1.2.1.18.6.2.1.9PhivCounter (0..255)read-onlymandatory
phivCircuitCountInitFailure
OBJECT-TYPE
Number of Initialization failures on this circuit.
1.3.6.1.2.1.18.6.2.1.10PhivCounter (0..255)read-onlymandatory
phivCircuitCountAdjDown
OBJECT-TYPE
This counter indicates the number of adjacency losses that result from any of the following: Node listener timeout Invalid data received at node listener Unexpected control (initialization or verification) message received Routing message received with a checksum error Node identification from a routing message or a Hello message that is not the one expected Hello message received indicating that connectivity became one-way Adjacency idled.
1.3.6.1.2.1.18.6.2.1.11PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountPeakAdj
OBJECT-TYPE
This counter indicates the maximum number of nodes that are up on the circuit.
1.3.6.1.2.1.18.6.2.1.12PhivCounter (0..65535)read-onlymandatory
phivCircuitCountBytesRecd
OBJECT-TYPE
Number of bytes received on this circuit.
1.3.6.1.2.1.18.6.2.1.13PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountBytesSent
OBJECT-TYPE
Number of bytes sent on this circuit.
1.3.6.1.2.1.18.6.2.1.14PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountDataBlocksRecd
OBJECT-TYPE
Number of data blocks received on this circuit.
1.3.6.1.2.1.18.6.2.1.15PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountDataBlocksSent
OBJECT-TYPE
Number of data blocks sent on this circuit.
1.3.6.1.2.1.18.6.2.1.16PhivCounter (0..2147483647)read-onlymandatory
phivCircuitCountUsrBuffUnav
OBJECT-TYPE
Number of user buffer unavailable errors.
1.3.6.1.2.1.18.6.2.1.17PhivCounter (0..65535)read-onlymandatory
phivCircuitOrigQueueLimit
OBJECT-TYPE
This parameter indicates the maximum number of originating packets that may be outstanding on this circuit. This does not include route-thru traffic.
1.3.6.1.2.1.18.6.3INTEGERread-writemandatory
phivCircuitCountZeroCount
OBJECT-TYPE
When this value is set to 2, all of the counters in the Circuit Counter Table are set to zero.
1.3.6.1.2.1.18.6.4INTEGER {other(1), reset(2)}read-writemandatory
ddcmp
OBJECT-IDENTITY
1.3.6.1.2.1.18.7
phivDDCMPCircuitParametersTable
OBJECT-TYPE
Information about DDCMP circuit parameters.
1.3.6.1.2.1.18.7.1not-accessiblemandatory
phivDDCMPCircuitParametersEntry
OBJECT-TYPE
Parameters information about DDCMP circuits currently known.
1.3.6.1.2.1.18.7.1.1not-accessiblemandatory
phivDDCMPCircuitIndex
OBJECT-TYPE
A unique index value for each known DDCMP circuit. This is the same value as phivCircuitIndex.
1.3.6.1.2.1.18.7.1.1.1INTEGER (1..65535)read-onlymandatory
phivDDCMPCircuitAdjNodeAddr
OBJECT-TYPE
The address of the adjacent node.
1.3.6.1.2.1.18.7.1.1.2PhivAddrread-onlymandatory
phivDDCMPCircuitTributary
OBJECT-TYPE
This value represents the Data Link physical tributary address of the circuit.
1.3.6.1.2.1.18.7.1.1.3INTEGER (0..255)read-onlymandatory
phivDDCMPCircuitCountTable
OBJECT-TYPE
Information about the DDCMP counters associated with all circuits currently known.
1.3.6.1.2.1.18.7.2not-accessiblemandatory
phivDDCMPCircuitCountEntry
OBJECT-TYPE
Counter information about DDCMP circuits now known
1.3.6.1.2.1.18.7.2.1not-accessiblemandatory
phivDDCMPCircuitErrorsInbd
OBJECT-TYPE
Number of Data errors inbound.
1.3.6.1.2.1.18.7.2.1.1PhivCounter (0..255)read-onlymandatory
phivDDCMPCircuitErrorsOutbd
OBJECT-TYPE
Number of outbound data errors.
1.3.6.1.2.1.18.7.2.1.2PhivCounter (0..255)read-onlymandatory
phivDDCMPCircuitRmteReplyTimeouts
OBJECT-TYPE
Number of remote reply timeouts.
1.3.6.1.2.1.18.7.2.1.3PhivCounter (0..255)read-onlymandatory
phivDDCMPCircuitLocalReplyTimeouts
OBJECT-TYPE
Number of local Reply timeouts.
1.3.6.1.2.1.18.7.2.1.4PhivCounter (0..255)read-onlymandatory
phivDDCMPCircuitRmteBuffErrors
OBJECT-TYPE
Number of remote reply time out errors.
1.3.6.1.2.1.18.7.2.1.5PhivCounter (0..255)read-onlymandatory
phivDDCMPCircuitLocalBuffErrors
OBJECT-TYPE
Number of local buffer errors.
1.3.6.1.2.1.18.7.2.1.6PhivCounter (0..255)read-onlymandatory
phivDDCMPCircuitSelectIntervalsElap
OBJECT-TYPE
Selection intervals that have elapsed.
1.3.6.1.2.1.18.7.2.1.7PhivCounter (0..65535)read-onlymandatory
phivDDCMPCircuitSelectTimeouts
OBJECT-TYPE
Number of selection timeouts.
1.3.6.1.2.1.18.7.2.1.8INTEGER (0..255)read-onlymandatory
phivDDCMPLineCountTable
OBJECT-TYPE
The DDCMP Line Count Table.
1.3.6.1.2.1.18.7.3not-accessiblemandatory
phivDDCMPLineCountEntry
OBJECT-TYPE
There is one entry in the table for each line.
1.3.6.1.2.1.18.7.3.1not-accessiblemandatory
phivDDCMPLineCountIndex
OBJECT-TYPE
The line on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of phivLineIndex. This value is the ifIndex.
1.3.6.1.2.1.18.7.3.1.1InterfaceIndexread-onlymandatory
phivDDCMPLineCountDataErrsIn
OBJECT-TYPE
Number of data errors inbound.
1.3.6.1.2.1.18.7.3.1.2PhivCounter (0..255)read-onlymandatory
phivDDCMPLineCountRmteStationErrs
OBJECT-TYPE
Number of remote station errors.
1.3.6.1.2.1.18.7.3.1.3PhivCounter (0..255)read-onlymandatory
phivDDCMPLineCountLocalStationErrs
OBJECT-TYPE
Number of local station errors.
1.3.6.1.2.1.18.7.3.1.4PhivCounter (0..255)read-onlymandatory
control
OBJECT-IDENTITY
1.3.6.1.2.1.18.8
phivControlSchedTimer
OBJECT-TYPE
This value represents the number of milliseconds between recalculation of tributary polling priorities.
1.3.6.1.2.1.18.8.1INTEGER (50..65535)read-onlymandatory
phivControlDeadTimer
OBJECT-TYPE
This value represents the number of milliseconds between polls of one of the set of dead tributaries.
1.3.6.1.2.1.18.8.2INTEGER (1..65535)read-onlymandatory
phivControlDelayTimer
OBJECT-TYPE
This value represents the minimum number of milliseconds to delay between polls. The delay timer limits the effect of a very fast control station on slow tributaries.
1.3.6.1.2.1.18.8.3INTEGER (1..65535)read-onlymandatory
phivControlStreamTimer
OBJECT-TYPE
This value represents the number of milliseconds a tributary or a half duplex remote station is allowed to hold the line. NOTE: This parameter can also be applied to half-duplex lines of type DDCMP POINT.
1.3.6.1.2.1.18.8.4INTEGER (0..65535)read-onlymandatory
phivControlParametersTable
OBJECT-TYPE
Information about control circuit parameters.
1.3.6.1.2.1.18.8.5not-accessiblemandatory
phivControlParametersEntry
OBJECT-TYPE
Parameters information about control circuits currently known.
1.3.6.1.2.1.18.8.5.1not-accessiblemandatory
phivControlCircuitIndex
OBJECT-TYPE
A unique index value for each known multipoint control circuit. This is the same value as phivCircuitIndex.
1.3.6.1.2.1.18.8.5.1.1INTEGER (1..65535)read-onlymandatory
phivControlBabbleTimer
OBJECT-TYPE
This value represents the number of milliseconds that a selected tributary or remote half-duplex station is allowed to transmit.
1.3.6.1.2.1.18.8.5.1.2INTEGER (1..65535)read-writemandatory
phivControlMaxBuffs
OBJECT-TYPE
This value represents the maximum number of buffers the tributary can use from a common buffer pool. If not set, there is no common buffer pool and buffers are explicitly supplied by the higher level. Count is a decimal integer in the range 1-254.
1.3.6.1.2.1.18.8.5.1.3INTEGER (1..254)read-writemandatory
phivControlMaxTransmits
OBJECT-TYPE
This value represents the maximum number of data messages that can be transmitted at one time. Count is a decimal integer in the range 1-255.
1.3.6.1.2.1.18.8.5.1.4INTEGER (1..255)read-writemandatory
phivControlDyingBase
OBJECT-TYPE
This value represents the base priority to which a tributary is reset each time it has been polled. A separate base can be set for each of the indicated polling states. Base is a decimal integer in the range 0-255. If not set, the defaults are: active, 255; inactive, 0; and dying, 0.
1.3.6.1.2.1.18.8.5.1.5INTEGER (0..255)read-writemandatory
phivControlDyingIncrement
OBJECT-TYPE
This value represents the increment added to the tributary priority each time the scheduling timer expires. If not set, the defaults are: active, 0; inactive, 64; and dying, 16.
1.3.6.1.2.1.18.8.5.1.6INTEGER (0..255)read-writemandatory
phivControlDeadThreshold
OBJECT-TYPE
This value represents the number of times to poll the active, inactive, or dying tributary before changing its polling state to dead because of receive timeouts. Count is a decimal integer in the range 0-255.
1.3.6.1.2.1.18.8.5.1.7INTEGER (0..255)read-writemandatory
phivControlDyingThreshold
OBJECT-TYPE
This value represents the number of times to poll the active or inactive tributary before changing its polling state to dying because of receive timeouts. Count is a decimal integer in the range 0-255.
1.3.6.1.2.1.18.8.5.1.8INTEGER (0..255)read-writemandatory
phivControlInactTreshold
OBJECT-TYPE
This value represents the number of times to poll the active tributary before changing its polling state to inactive because of no data response. Count is a decimal integer in the range 0-255.
1.3.6.1.2.1.18.8.5.1.9INTEGER (0..255)read-writemandatory
phivControlPollingState
OBJECT-TYPE
This value represents the state of the tributary relative to the multipoint polling algorithm. If not set the default is AUTOMATIC. The possible states are: AUTOMATIC The tributary's state is allowed to vary according to the operation of the polling algorithm. ACTIVE/INACTIVE/DYING/DEAD The tributary is locked in the specified state. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155.
1.3.6.1.2.1.18.8.5.1.10INTEGER {automatic(1), active(2), inactive(3), dying(4), dead(5)}read-writemandatory
phivControlPollingSubState
OBJECT-TYPE
This value represents the tributary's state as determined by the polling algorithm. This applies only when the polling state is AUTOMATIC and is read-only to Network Management. Polling-substate is one of ACTIVE, INACTIVE, DYING, or DEAD. It is displayed as a tag on the polling state, for example: AUTOMATIC-INACTIVE.
1.3.6.1.2.1.18.8.5.1.11INTEGER {active(1), inactive(2), dying(3), dead(4)}read-onlymandatory
phivControlTransTimer
OBJECT-TYPE
This value represents the number of milliseconds to delay between data message transmits. Milliseconds is a decimal integer in the range 0-65535.
1.3.6.1.2.1.18.8.5.1.12INTEGER (0..65535)read-writemandatory
ethernet
OBJECT-IDENTITY
1.3.6.1.2.1.18.9
phivEthLinkParametersTable
OBJECT-TYPE
Information about ethernet link parameters.
1.3.6.1.2.1.18.9.1not-accessiblemandatory
phivEthLinkParametersEntry
OBJECT-TYPE
Parameter information about ethernet links currently known.
1.3.6.1.2.1.18.9.1.1not-accessiblemandatory
phivEthLinkIndex
OBJECT-TYPE
The circuit over which this links information is collected. This is the same as phivCircuitIndex.
1.3.6.1.2.1.18.9.1.1.1INTEGER (1..65535)read-onlymandatory
phivEthDesigRouterNodeAddr
OBJECT-TYPE
This value is the address of the designated router.
1.3.6.1.2.1.18.9.1.1.2PhivAddrread-onlymandatory
phivEthMaxRouters
OBJECT-TYPE
This parameter is the maximum number of routers (other than the executor itself) allowed on the circuit by Routing for circuits that are owned by the executor node.
1.3.6.1.2.1.18.9.1.1.3INTEGER (0..255)read-writemandatory
phivEthRouterPri
OBJECT-TYPE
This parameter is the priority that this router is to have in the selection of designated router for the circuit on circuits that are owned by the executor node.
1.3.6.1.2.1.18.9.1.1.4INTEGER (0..127)read-writemandatory
phivEthHardwareAddr
OBJECT-TYPE
This read-only parameter is the address that is associated with the line device hardware as seen by the DECnet Software. This value is not the same as ifPhysAddress.
1.3.6.1.2.1.18.9.1.1.5OCTET STRING (SIZE(6))read-onlymandatory
counters
OBJECT-IDENTITY
1.3.6.1.2.1.18.10
phivCountersCountTable
OBJECT-TYPE
Information about ethernet link counters.
1.3.6.1.2.1.18.10.1not-accessiblemandatory
phivCountersCountEntry
OBJECT-TYPE
Counter information about ethernet links currently known.
1.3.6.1.2.1.18.10.1.1not-accessiblemandatory
phivCountersIndex
OBJECT-TYPE
The interface to which these counters apply. This is the same interface as identified by the same value of phivLineIndex. This value is the ifIndex.
1.3.6.1.2.1.18.10.1.1.1InterfaceIndexread-onlymandatory
phivCountersCountBytesRecd
OBJECT-TYPE
Number of bytes received over this link.
1.3.6.1.2.1.18.10.1.1.2PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountBytesSent
OBJECT-TYPE
Number of bytes sent over this link.
1.3.6.1.2.1.18.10.1.1.3PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountDataBlocksRecd
OBJECT-TYPE
Number of data blocks received over this link.
1.3.6.1.2.1.18.10.1.1.4PhivCounter (0..2147483647)read-onlyobsolete
phivCountersCountDataBlocksSent
OBJECT-TYPE
Number of data blocks sent over this link.
1.3.6.1.2.1.18.10.1.1.5PhivCounter (0..2147483647)read-onlyobsolete
phivCountersCountEthUsrBuffUnav
OBJECT-TYPE
Number of user buffer unavailable errors over this link.
1.3.6.1.2.1.18.10.1.1.6PhivCounter (0..65535)read-onlymandatory
phivCountersCountMcastBytesRecd
OBJECT-TYPE
Number of multicast bytes received over this link.
1.3.6.1.2.1.18.10.1.1.7PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountDataBlksRecd
OBJECT-TYPE
Number of data blocks received over this link.
1.3.6.1.2.1.18.10.1.1.8PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountDataBlksSent
OBJECT-TYPE
Number of data blocks sent over this link.
1.3.6.1.2.1.18.10.1.1.9PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountMcastBlksRecd
OBJECT-TYPE
Number of multicast blocks received over this link.
1.3.6.1.2.1.18.10.1.1.10PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountBlksSentDef
OBJECT-TYPE
Number of blocks sent, initially deferred over this link.
1.3.6.1.2.1.18.10.1.1.11PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountBlksSentSingleCol
OBJECT-TYPE
Number of blocks sent, single collision over this link.
1.3.6.1.2.1.18.10.1.1.12PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountBlksSentMultCol
OBJECT-TYPE
Number of blocks sent, multiple collisions over this link.
1.3.6.1.2.1.18.10.1.1.13PhivCounter (0..2147483647)read-onlymandatory
phivCountersCountSendFailure
OBJECT-TYPE
Number of send failures over this link.
1.3.6.1.2.1.18.10.1.1.14INTEGER (0..65535)read-onlymandatory
phivCountersCountCollDetectFailure
OBJECT-TYPE
Number of collision detect check failures over this link.
1.3.6.1.2.1.18.10.1.1.15INTEGER (0..65535)read-onlymandatory
phivCountersCountReceiveFailure
OBJECT-TYPE
Number of receive failures over this link.
1.3.6.1.2.1.18.10.1.1.16INTEGER (0..65535)read-onlymandatory
phivCountersCountUnrecFrameDest
OBJECT-TYPE
Number of unrecognized frame destinations over this link.
1.3.6.1.2.1.18.10.1.1.17INTEGER (0..65535)read-onlymandatory
phivCountersCountDataOver
OBJECT-TYPE
Number of data overruns over this link.
1.3.6.1.2.1.18.10.1.1.18INTEGER (0..65535)read-onlymandatory
phivCountersCountSysBuffUnav
OBJECT-TYPE
Number of system buffer unavailables over this link.
1.3.6.1.2.1.18.10.1.1.19INTEGER (0..65535)read-onlymandatory
phivCountersCountUsrBuffUnav
OBJECT-TYPE
Number of user buffer unavailables.
1.3.6.1.2.1.18.10.1.1.20INTEGER (0..65535)read-onlymandatory
adjacency
OBJECT-IDENTITY
1.3.6.1.2.1.18.11
phivAdjTable
OBJECT-TYPE
The Adjacency Table.
1.3.6.1.2.1.18.11.1not-accessibleobsolete
phivAdjEntry
OBJECT-TYPE
There is one entry in the table for each adjacency.
1.3.6.1.2.1.18.11.1.1not-accessibleobsolete
phivAdjCircuitIndex
OBJECT-TYPE
A unique index value for each known circuit.
1.3.6.1.2.1.18.11.1.1.1INTEGERread-onlyobsolete
phivAdjNodeAddr
OBJECT-TYPE
The address of the adjacent node.
1.3.6.1.2.1.18.11.1.1.2PhivAddrread-onlyobsolete
phivAdjBlockSize
OBJECT-TYPE
This read-only parameter is the block size that was negotiated with the adjacent Routing layer during Routing initialization over a particular circuit. It includes the routing header, but excludes the data link header. This parameter is qualified by ADJACENT NODE.
1.3.6.1.2.1.18.11.1.1.3INTEGERread-onlyobsolete
phivAdjListenTimer
OBJECT-TYPE
This value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer. This parameter is qualified by ADJACENT NODE.
1.3.6.1.2.1.18.11.1.1.4INTEGER (1..65535)read-onlyobsolete
phivAdjCircuitEtherServPhysAddr
OBJECT-TYPE
This parameter indicates the Ethernet physical address of an adjacent node that is being serviced on this circuit. This parameter is a qualifier for SERVICE SUBSTATE.
1.3.6.1.2.1.18.11.1.1.5OCTET STRING (SIZE(6))read-onlyobsolete
phivAdjType
OBJECT-TYPE
This parameter indicates the type of adjacency. For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The routing-III and nonrouting-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)
1.3.6.1.2.1.18.11.1.1.6INTEGER {routing-III(1), nonrouting-III(2), area(3), routing-IV(4), nonrouting-IV(5)}read-onlyobsolete
phivAdjState
OBJECT-TYPE
This value indicates the state of a router adjacency. On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjType) ROUTING IV or AREA, this variable is the state of the Ethernet Initialization Layer for this adjacency, and can have values INITIALIZING or UP. (See Section 9.1.1 of DECnet Phase IV Routing Layer Functional Specification.) On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjType) NONROUTING IV, this variable will always take on the value UP. On adjacencies over a circuit of type (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL, DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is the state of the Routing Layer Initialization Circuit State. (See section 7.3, ibid.) It can have values between RUN and HALT. On adjacencies over a circuit of type (phivCircuitCommonType) OTHER, this variable may be used in a manner consistent with the Initialization Layer used on that circuit.
1.3.6.1.2.1.18.11.1.1.7INTEGER {initializing(1), up(2), run(3), circuit-rejected(4), data-link-start(5), routing-layer-initialize(6), routing-layer-verify(7), routing-layer-complete(8), off(9), halt(10)}read-onlyobsolete
phivAdjPriority
OBJECT-TYPE
Priority assigned by the adjacent node for this circuit.
1.3.6.1.2.1.18.11.1.1.8INTEGER (0..255)read-onlyobsolete
phivAdjExecListenTimer
OBJECT-TYPE
This read-only value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer.
1.3.6.1.2.1.18.11.1.1.9INTEGER (1..65535)read-onlyobsolete
phivAdjNodeTable
OBJECT-TYPE
The Adjacent Node Table.
1.3.6.1.2.1.18.11.2not-accessiblemandatory
phivAdjNodeEntry
OBJECT-TYPE
There is one entry in the table for each adjacency.
1.3.6.1.2.1.18.11.2.1not-accessiblemandatory
phivAdjNodeCircuitIndex
OBJECT-TYPE
A unique index value for each known circuit. This value is the same as phivCircuitIndex and identifies the circuit over which the adjacency is realized.
1.3.6.1.2.1.18.11.2.1.1INTEGER (1..65535)read-onlymandatory
phivAdjAddr
OBJECT-TYPE
The address of the adjacent node.
1.3.6.1.2.1.18.11.2.1.2PhivAddrread-onlymandatory
phivAdjNodeBlockSize
OBJECT-TYPE
This read-only parameter is the block size that was negotiated with the adjacent Routing layer during Routing initialization over a particular circuit. It includes the routing header, but excludes the data link header. This parameter is qualified by ADJACENT NODE.
1.3.6.1.2.1.18.11.2.1.3INTEGERread-onlymandatory
phivAdjNodeListenTimer
OBJECT-TYPE
This value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer. This parameter is qualified by ADJACENT NODE.
1.3.6.1.2.1.18.11.2.1.4INTEGER (1..65535)read-onlymandatory
phivAdjNodeCircuitEtherServPhysAddr
OBJECT-TYPE
This parameter indicates the Ethernet physical address of an adjacent node that is being serviced on this circuit. This parameter is a qualifier for SERVICE SUBSTATE.
1.3.6.1.2.1.18.11.2.1.5OCTET STRING (SIZE(6))read-onlymandatory
phivAdjNodeType
OBJECT-TYPE
This parameter indicates the type of adjacency. For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The routing-III and nonrouting-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)
1.3.6.1.2.1.18.11.2.1.6INTEGER {routing-III(1), nonrouting-III(2), area(3), routing-IV(4), nonrouting-IV(5)}read-onlymandatory
phivAdjNodeState
OBJECT-TYPE
This value indicates the state of a router adjacency. On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjNodeType) ROUTING IV or AREA, this variable is the state of the Ethernet Initialization Layer for this adjacency, and can have values INITIALIZING or UP. (See Section 9.1.1 of DECnet Phase IV Routing Layer Functional Specification.) On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjNodeType) NONROUTING IV, this variable will always take on the value UP. On adjacencies over a circuit of type (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL, DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is the state of the Routing Layer Initialization Circuit State. (See section 7.3, ibid.) It can have values between RUN and HALT. On adjacencies over a circuit of type (phivCircuitCommonType) OTHER, this variable may be used in a manner consistent with the Initialization Layer used on that circuit.
1.3.6.1.2.1.18.11.2.1.7INTEGER {initializing(1), up(2), run(3), circuit-rejected(4), data-link-start(5), routing-layer-initialize(6), routing-layer-verify(7), routing-layer-complete(8), off(9), halt(10)}read-onlymandatory
phivAdjNodePriority
OBJECT-TYPE
Priority assigned by the adjacent node for this circuit.
1.3.6.1.2.1.18.11.2.1.8INTEGER (0..255)read-onlymandatory
line
OBJECT-IDENTITY
1.3.6.1.2.1.18.12
phivLineTable
OBJECT-TYPE
The Line Table.
1.3.6.1.2.1.18.12.1not-accessiblemandatory
phivLineEntry
OBJECT-TYPE
There is one entry in the table for each line.
1.3.6.1.2.1.18.12.1.1not-accessiblemandatory
phivLineIndex
OBJECT-TYPE
The line on which this entry's equivalence is effective. This is the same as the ifIndex.
1.3.6.1.2.1.18.12.1.1.1InterfaceIndexread-onlymandatory
phivLineName
OBJECT-TYPE
The name of the line on this row of the table.
1.3.6.1.2.1.18.12.1.1.2DisplayString (SIZE(0..16))read-onlymandatory
phivLineState
OBJECT-TYPE
This value represents Network Management operational state. NOTE that these values are incremented by one compared to the standard DECnet values.
1.3.6.1.2.1.18.12.1.1.3INTEGER {on(1), off(2), service(3), cleared(4)}read-onlymandatory
phivLineSubstate
OBJECT-TYPE
This value represents the line's read-only Network Management substate. NOTE that these values are incremented by one compared to the standard DECnet values.
1.3.6.1.2.1.18.12.1.1.4INTEGER {starting(1), reflecting(2), looping(3), loading(4), dumping(5), triggering(6), auto-service(7), auto-loading(8), auto-dumping(9), auto-triggering(10), synchronizing(11), failed(12), running(13)}read-onlymandatory
phivLineService
OBJECT-TYPE
This value represents the line's read-only Network Management service. NOTE that these values are incremented by one compared to the standard DECnet values and OTHER is a new addition.
1.3.6.1.2.1.18.12.1.1.5INTEGER {starting(1), reflecting(2), looping(3), other(4)}read-onlymandatory
phivLineDevice
OBJECT-TYPE
This value represents the Physical Link device to be used on the line.
1.3.6.1.2.1.18.12.1.1.6DisplayString (SIZE(0..16))read-onlymandatory
phivLineReceiveBuffs
OBJECT-TYPE
This value represents the number of receive buffers reserved for the line. It is a decimal number in the range 0-65535. 0 is supported for those vendors that do not reserve buffers on a per line basis and use a pool of buffers that can be used by any line.
1.3.6.1.2.1.18.12.1.1.7INTEGER (0..65535)read-onlymandatory
phivLineProtocol
OBJECT-TYPE
This value represents the protocol used on the line device. Note that these values are incremented by one compared to the standard DECnet values.
1.3.6.1.2.1.18.12.1.1.8INTEGER {ddcmp-point(1), ddcmp-control(2), ddcmp-tributary(3), reserved(4), ddcmp-dmc(5), olapb(6), ethernet(7), ci(8), qp2(9), other(14), fddi(15)}read-onlymandatory
phivLineServiceTimer
OBJECT-TYPE
This value represents the amount of time in milliseconds allowed to elapse before a Data Link receive request completes while doing service operations.
1.3.6.1.2.1.18.12.1.1.9INTEGER (1..65535)read-onlymandatory
phivLineMaxBlock
OBJECT-TYPE
This value represents the Data Link maximum block size on the line.
1.3.6.1.2.1.18.12.1.1.10INTEGER (1..65535)read-onlymandatory
nonBroadcastLine
OBJECT-IDENTITY
1.3.6.1.2.1.18.14
phivNonBroadcastTable
OBJECT-TYPE
The Non Broadcast Table.
1.3.6.1.2.1.18.14.1not-accessiblemandatory
phivNonBroadcastEntry
OBJECT-TYPE
There is one entry in the table for each Non Broadcast line.
1.3.6.1.2.1.18.14.1.1not-accessiblemandatory
phivNonBroadcastIndex
OBJECT-TYPE
The Non Broadcast line on which this entry's equivalence is effective. This is the same value as the ifIndex.
1.3.6.1.2.1.18.14.1.1.1InterfaceIndexread-onlymandatory
phivNonBroadcastController
OBJECT-TYPE
This value represents the Physical Link hardware controller mode for the line device. The values for controller-mode are: NORMAL For normal controller operating mode. LOOPBACK For software controllable loopback of the controller. On those devices that can support this mode, it causes all transmitted messages to be looped back from within the controller itself. This is accomplished without any manual intervention other than the setting of this parameter value. OTHER indicates function is not supported Note that these values are incremented by one compared to the standard DECnet values.
1.3.6.1.2.1.18.14.1.1.2INTEGER {normal(1), loopback(2), other(3)}read-onlymandatory
phivNonBroadcastDuplex
OBJECT-TYPE
This value represents the Physical Link hardware duplex mode of the line device. The possible modes are: FULL Full-duplex HALF Half-duplex Note that these values are incremented by one compared to the standard DECnet values.
1.3.6.1.2.1.18.14.1.1.3INTEGER {full(1), half(2)}read-onlymandatory
phivNonBroadcastClock
OBJECT-TYPE
This value represents the Physical Link hardware clock mode for the line device. The values for clock-mode are: INTERNAL For software controllable loopback use of the clock. On those devices that can support this mode, it causes the device to supply a clock signal such that a transmitted messages can be looped back from outside the device. This may require manual intervention other than the setting of this parameter value. For example, the operator may have to connect a loopback plug in place of the normal line. EXTERNAL For normal clock operating mode, where the clock signal is supplied externally to the controller. Note that these values are incremented by one compared to the standard DECnet values.
1.3.6.1.2.1.18.14.1.1.4INTEGER {external(1), internal(2), other(3)}read-onlymandatory
phivNonBroadcastRetransmitTimer
OBJECT-TYPE
This value represents number of milliseconds before the Data Link retransmits a block on the line. On half-duplex lines, this parameter is the select timer.
1.3.6.1.2.1.18.14.1.1.5INTEGER (1..65535)read-onlymandatory
area
OBJECT-IDENTITY
1.3.6.1.2.1.18.15
phivAreaTable
OBJECT-TYPE
Table of information kept on all areas known to this unit.
1.3.6.1.2.1.18.15.1not-accessiblemandatory
phivAreaEntry
OBJECT-TYPE
The area routing information.
1.3.6.1.2.1.18.15.1.1not-accessiblemandatory
phivAreaNum
OBJECT-TYPE
This value indicates the area number of this entry.
1.3.6.1.2.1.18.15.1.1.1INTEGER (0..64)read-onlymandatory
phivAreaState
OBJECT-TYPE
This value indicates the state of the area
1.3.6.1.2.1.18.15.1.1.2INTEGER {reachable(4), unreachable(5)}read-onlymandatory
phivAreaCost
OBJECT-TYPE
The total cost over the current path to the destination area. Cost is a value associated with using a circuit. Routing routes messages (data) along the path between 2 areas with the smallest cost.
1.3.6.1.2.1.18.15.1.1.3Gaugeread-onlymandatory
phivAreaHops
OBJECT-TYPE
The number of hops to a destination area. A hop is the routing value representing the logical distance between two areas in network.
1.3.6.1.2.1.18.15.1.1.4INTEGER (0..255)read-onlymandatory
phivAreaNextNode
OBJECT-TYPE
The next node on the circuit used to get to the area under scrutiny.
1.3.6.1.2.1.18.15.1.1.5PhivAddrread-onlymandatory
phivAreaCircuitIndex
OBJECT-TYPE
A unique index value for each known circuit.
1.3.6.1.2.1.18.15.1.1.6INTEGER (1..65535)read-onlymandatory
phivAreaMaxCost
OBJECT-TYPE
This value represents the maximum total path cost allowed from the executor to any other level 2 routing node. The AREA MAXIMUM COST number is decimal in the range 1-1022. This parameter is only applicable if the executor node is of type AREA.
1.3.6.1.2.1.18.15.2INTEGER (1..1022)read-writemandatory
phivAreaMaxHops
OBJECT-TYPE
This value represents the maximum number of routing hops allowable from the executor to any other level 2 routing node. This parameter is only applicable if the executor node is of type AREA.
1.3.6.1.2.1.18.15.3INTEGER (1..30)read-writemandatory
phivRouteMaxArea
OBJECT-TYPE
This value represents the largest area number and, therefore, number of areas that can be known about by the executor node's Routing. This parameter is only applicable if the executor node is of type AREA.
1.3.6.1.2.1.18.15.4INTEGER (1..63)read-writemandatory