MIBs Depot

DDM-MGMT-MIB

Registered at
1.3.6.1.4.1.171.12.72
Last updated
1909-04-30 00:00
Organization
D-Link Corp.
Namespace
dlink
Source file
DDM-MGMT-MIB
Digest
sha256:31cb1121a58c2043a46e4b928471e331f2569a65e88ddde6b9cb58c78e5d7690

Description

The structure of DDM for the proprietary enterprise.

Contact

http://support.dlink.com

Imports

FromSymbols
DLINK-ID-REC-MIBdlink-common-mgmt
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DDM-MGMT-MIB
DLINK-ID-REC-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
swDdmCtrl
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.1
swDdmTrapState
OBJECT-TYPE
This object indicates the trap action state.
1.3.6.1.4.1.171.12.72.1.1INTEGER {enabled(1), disabled(2)}read-writecurrent
swDdmLogState
OBJECT-TYPE
This object indicates the log action state.
1.3.6.1.4.1.171.12.72.1.2INTEGER {enabled(1), disabled(2)}read-writecurrent
swDdmInfo
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.2
swDdmStatus
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.2.1
swDdmStatusTable
OBJECT-TYPE
This table contains the DDM status information.
1.3.6.1.4.1.171.12.72.2.1.1not-accessiblecurrent
swDdmStatusEntry
OBJECT-TYPE
This is an entry of the swDdmStatusTable.
1.3.6.1.4.1.171.12.72.2.1.1.1not-accessiblecurrent
swDdmPort
OBJECT-TYPE
This object indicates the port.
1.3.6.1.4.1.171.12.72.2.1.1.1.1INTEGER (1..65535)read-onlycurrent
swDdmTemperature
OBJECT-TYPE
This object indicates the real time value of the temperature. As the value is a floating point data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.2.1.1.1.2DisplayStringread-onlycurrent
swDdmVoltage
OBJECT-TYPE
This object indicates the real time value of the supply voltage. As the value value is a floating point data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.2.1.1.1.3DisplayStringread-onlycurrent
swDdmBiasCurrent
OBJECT-TYPE
This object indicates the real time value of the tx bias.
1.3.6.1.4.1.171.12.72.2.1.1.1.4DisplayStringread-onlycurrent
swDdmTxPower
OBJECT-TYPE
This object indicates the real time value of the tx power. As the value is a floating point data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.2.1.1.1.5DisplayStringread-onlycurrent
swDdmRxPower
OBJECT-TYPE
This object indicates the real time value of the rx power. As the value is a floating data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.2.1.1.1.6DisplayStringread-onlycurrent
swDdmMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.3
swDdmThresholdMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.3.1
swDdmThresholdMgmtTable
OBJECT-TYPE
This table contains DDM temperature configuration information.
1.3.6.1.4.1.171.12.72.3.1.1not-accessiblecurrent
swDdmThresholdMgmtEntry
OBJECT-TYPE
This is an entry of the swDdmConfigThresholdTable.
1.3.6.1.4.1.171.12.72.3.1.1.1not-accessiblecurrent
swDdmThresholdType
OBJECT-TYPE
This object indicates the threshold type.
1.3.6.1.4.1.171.12.72.3.1.1.1.1INTEGER {temperature(1), voltage(2), bias(3), txPower(4), rxPower(5)}read-onlycurrent
swDdmHighAlarm
OBJECT-TYPE
This object indicates the high alarm threshold value to be configured. As the value is a floating point data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.3.1.1.1.2DisplayStringread-writecurrent
swDdmLowAlarm
OBJECT-TYPE
This object indicates the low alarm threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.3.1.1.1.3DisplayStringread-writecurrent
swDdmHighWarning
OBJECT-TYPE
This object indicates the high warning threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.3.1.1.1.4DisplayStringread-writecurrent
swDdmLowWarning
OBJECT-TYPE
This object indicates the low warning threshold value to be configured. As the value is a floating data type, the DisplayString type is used to define this parameter.
1.3.6.1.4.1.171.12.72.3.1.1.1.5DisplayStringread-writecurrent
swDdmActionMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.3.2
swDdmActionMgmtTable
OBJECT-TYPE
This table contains the configuration of the action taken when any parameter exceeds its threshold.
1.3.6.1.4.1.171.12.72.3.2.1not-accessibleobsolete
swDdmActionMgmtEntry
OBJECT-TYPE
This is an entry of the swDdmConfigActionTable.
1.3.6.1.4.1.171.12.72.3.2.1.1not-accessibleobsolete
swDdmActionType
OBJECT-TYPE
This object indicates the action type.
1.3.6.1.4.1.171.12.72.3.2.1.1.1INTEGER {alarm(1), warning(2)}read-onlyobsolete
swDdmShutdown
OBJECT-TYPE
This object indicates the shutdown action. The value 'other' means that the port does not support DDM.
1.3.6.1.4.1.171.12.72.3.2.1.1.2INTEGER {enabled(1), disabled(2), other(3)}read-writeobsolete
swDdmTrapAndLog
OBJECT-TYPE
This object indicates the trap and log action. The value 'other' means that the port does not support DDM.
1.3.6.1.4.1.171.12.72.3.2.1.1.3INTEGER {enabled(1), disabled(2), other(3)}read-writeobsolete
swDdmPortMgmtTable
OBJECT-TYPE
This table contains the configuration of the DDM state and shutdown mode when any parameter exceeds its threshold.
1.3.6.1.4.1.171.12.72.3.2.2not-accessiblecurrent
swDdmPortMgmtEntry
OBJECT-TYPE
This is an entry of the swDdmPortMgmtTable.
1.3.6.1.4.1.171.12.72.3.2.2.1not-accessiblecurrent
swDdmPortState
OBJECT-TYPE
This object indicates the DDM state information by port.
1.3.6.1.4.1.171.12.72.3.2.2.1.1INTEGER {enabled(1), disabled(2)}read-writecurrent
swDdmPortShutdown
OBJECT-TYPE
This object indicates whether or not to shutdown the port on which the operating parameter exceeds the specified threshold.
1.3.6.1.4.1.171.12.72.3.2.2.1.2INTEGER {alarm(1), warning(2), none(3), other(4)}read-writecurrent
swDdmNotify
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.4
swDdmNotifyPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.4.0
swDdmNotificationBinding
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.72.4.1
swDdmThresholdExceedType
OBJECT-TYPE
This object is used by swDdmAlarmTrap and swDdmWarningTrap to indicate if the threshold that was exceeded was a high threshold or a low threshold.
1.3.6.1.4.1.171.12.72.4.1.1INTEGER {high(1), low(2)}accessible-for-notifycurrent
swDdmThresholdExceedOrRecover
OBJECT-TYPE
This object is used by swDdmAlarmTrap and swDdmWarningTrap,to indicate the GBIC is exceeding its ddm threshold or recover to normal status.
1.3.6.1.4.1.171.12.72.4.1.2INTEGER {exceed(1), recover(2)}accessible-for-notifycurrent

Notifications

NameOIDStatus
swDdmAlarmTrap
NOTIFICATION-TYPE
The trap is sent when any parameter value exceeds the alarm threshold value or recover to normal status depending on the configuration of the trap action.
1.3.6.1.4.1.171.12.72.4.0.1current
swDdmWarningTrap
NOTIFICATION-TYPE
The trap is sent when any parameter value exceeds the warning threshold value or recover to normal status depending on the configuration of the trap action.
1.3.6.1.4.1.171.12.72.4.0.2current