MIBs Depot

DATA-DOMAIN-MIB

Registered at
1.3.6.1.4.1.19746
Last updated
2017-05-16 00:00
Organization
Data Domain, Inc
Revisions
2017-05-16 00:00
Namespace
datadomain
Source file
DATA-DOMAIN-MIB
Digest
sha256:306f0ec9c95ebddaa174647cc661e1b7585e721d2502c77be6ba1fdf1aac650a

Description

This MIB is used for managing the suite of Data Domain Products.

Contact

Phone: +1-408-980-4800 Fax: +1-408-980-8620

Imports

FromSymbols
IF-MIBifDescr, ifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Counter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DATA-DOMAIN-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AlertDescriptionTC
TEXTUAL-CONVENTION
Alert Description
current
AlertIndexTC
TEXTUAL-CONVENTION
Alert Row Index
current
AlertTimestampTC
TEXTUAL-CONVENTION
Alert Timestamp
current
CifsConfigDNSTC
TEXTUAL-CONVENTION
CIFS DNS server
current
CifsConfigDomainControllerTC
TEXTUAL-CONVENTION
CIFS Domain Controller
current
CifsConfigGroupNameTC
TEXTUAL-CONVENTION
CIFS group name
current
CifsConfigMaxConnectionTC
TEXTUAL-CONVENTION
CIFS configuration maximum connection
current
CifsConfigMaxOpenFilesPerConnectionTC
TEXTUAL-CONVENTION
CIFS configuration maximum open files per connection
current
CifsConfigModeTC
TEXTUAL-CONVENTION
Current CIFS mode
current
CifsConfigNetBIOSHostnameTC
TEXTUAL-CONVENTION
CIFS NetBIOS hostname
current
CifsConfigWINSServerTC
TEXTUAL-CONVENTION
CIFS WINS servers
current
CifsOptionsIndexTC
TEXTUAL-CONVENTION
Index of CIFS Option Table Index
current
CifsOptionsNameTC
TEXTUAL-CONVENTION
Index of CIFS Option Name
current
CifsOptionsValueTC
TEXTUAL-CONVENTION
Index of CIFS Option Value
current
CifsShareBrowsingTC
TEXTUAL-CONVENTION
Current CIFS browsing
current
CifsShareClientsTC
TEXTUAL-CONVENTION
CIFS share clients
current
CifsShareCommentTC
TEXTUAL-CONVENTION
CIFS share comment
current
CifsShareIndexTC
TEXTUAL-CONVENTION
Index of CIFS share
current
CifsShareMaxConnectionTC
TEXTUAL-CONVENTION
CIFS maximum connection
current
CifsShareNameTC
TEXTUAL-CONVENTION
CIFS share name
current
CifsSharePathTC
TEXTUAL-CONVENTION
CIFS share path
current
CifsShareUserTC
TEXTUAL-CONVENTION
CIFS share user
current
CifsShareWriteableTC
TEXTUAL-CONVENTION
Current CIFS writeable
current
CifsStatsDetailsIndexTC
TEXTUAL-CONVENTION
Index of CIFS Stats Details Table
current
CifsStatsSummaryIndexTC
TEXTUAL-CONVENTION
Index of Cifs Stats Summary Table
current
CifsStatusTC
TEXTUAL-CONVENTION
Current CIFS status
current
DDMibAlertSeverityTC
TEXTUAL-CONVENTION
Data Domain Alert Severity
current
DDMibCompressionFactorTC
TEXTUAL-CONVENTION
Data Domain compression factor
current
DDMibDateTC
TEXTUAL-CONVENTION
Data Domain Mib Date in the yyyy-mm-dd hh:mm format
current
DDMibInteger32TC
TEXTUAL-CONVENTION
Data Domain Mib Integer 32.
current
DDMibMemorySizeTC
TEXTUAL-CONVENTION
Data Domain Mib Memory Size of in bytes.
current
DDMibStatusTC
TEXTUAL-CONVENTION
DD Mib Status
current
DDMibString96TC
TEXTUAL-CONVENTION
DD Mib String 96
current
DDMibTableEnabledTC
TEXTUAL-CONVENTION
DD Mib Table Enabled
current
DDMibTableIndexTC
TEXTUAL-CONVENTION
Index for Any Data Domain MIB table
current
DDMibTableSizeGibTC
TEXTUAL-CONVENTION
Data Domain Compression size in GiB
current
DDMibTableSizeMiBTC
TEXTUAL-CONVENTION
Data Domain size in MiB
current
DDMibTableString1024TC
TEXTUAL-CONVENTION
DD Mib Table String 1024
current
DDMibTableString128TC
TEXTUAL-CONVENTION
DD Mib Table String 128
current
DDMibTableString256TC
TEXTUAL-CONVENTION
DD Mib Table String 256
current
DDMibTableString32TC
TEXTUAL-CONVENTION
DD Mib Table String 32
current
DDMibTableString512TC
TEXTUAL-CONVENTION
DD Mib Table String 512
current
DDMibTableString64TC
TEXTUAL-CONVENTION
DD Mib Table String 64
current
DDMibTimeStampTC
TEXTUAL-CONVENTION
DD Mib Timestamp
current
DDMibTrafficBytesTC
TEXTUAL-CONVENTION
measurement of bytes being transferred
current
DDMibVersionTC
TEXTUAL-CONVENTION
Data Domain Mib version
current
DDStatusTC
TEXTUAL-CONVENTION
DD feature Status
current
DDboostStatsIndexTC
TEXTUAL-CONVENTION
Index of ddboost Stats Table
current
DDboostStatusTC
TEXTUAL-CONVENTION
DDboost Status
current
DDboostUserTC
TEXTUAL-CONVENTION
DDboost user
current
DateTC
TEXTUAL-CONVENTION
Date in the yyyy-mm-dd hh:mm format
current
DdboostAccessClientsAuthModeTC
TEXTUAL-CONVENTION
The types of Ddboost access clients authentication mode
current
DdboostAccessClientsEncryStrengthTC
TEXTUAL-CONVENTION
The types of Ddboost access clients encryption strength level
current
DiskCapacityTC
TEXTUAL-CONVENTION
Capacity of disk
current
DiskFirmwareVersionTC
TEXTUAL-CONVENTION
Firmware version of disk
current
DiskIndexTC
TEXTUAL-CONVENTION
Disk Number of disk that is present in the DDR
current
DiskModelTC
TEXTUAL-CONVENTION
Manufacture & Model Number of disk
current
DiskPackTC
TEXTUAL-CONVENTION
Pack number for disks of ES60.
current
DiskSectorsPerSecondTC
TEXTUAL-CONVENTION
Number of disk sectors being transferred per second
current
DiskSerialNumberTC
TEXTUAL-CONVENTION
Serial Number of disk
current
DiskStateTC
TEXTUAL-CONVENTION
Current Disk State
current
EnclosureID
TEXTUAL-CONVENTION
unique Enclosure ID, used as index in several tables
current
ErrorCount
TEXTUAL-CONVENTION
Number of Errors Encountered
current
FanDescriptionTC
TEXTUAL-CONVENTION
Fan Description
current
FanIndexTC
TEXTUAL-CONVENTION
Fan Number of fan that is present in DDR
current
FanLevelTC
TEXTUAL-CONVENTION
Current Fan level
current
FanStatusTC
TEXTUAL-CONVENTION
Current Fan Status
current
FileSystemArchiveUnitStateTC
TEXTUAL-CONVENTION
File System Archive Unit State
current
FileSystemArchiveUnitStatusTC
TEXTUAL-CONVENTION
File System Archive Unit Status
current
FileSystemCleanIndexTC
TEXTUAL-CONVENTION
File System Clean Index
current
FileSystemCleanScheduleTC
TEXTUAL-CONVENTION
File System Clean Schedule
current
FileSystemCleanStatusTC
TEXTUAL-CONVENTION
File System Clean Status
current
FileSystemCleanThrottleTC
TEXTUAL-CONVENTION
File System Clean throttle
current
FileSystemCompressionFactorTC
TEXTUAL-CONVENTION
File System compression factor
current
FileSystemCompressionPeriodTC
TEXTUAL-CONVENTION
File System compression period: last 24 hours, last 7 days
current
FileSystemCompressionSizeTC
TEXTUAL-CONVENTION
File Systems Compression size in GiB
current
FileSystemOptionsIndexTC
TEXTUAL-CONVENTION
Index of File System Option Table Index
current
FileSystemOptionsNameTC
TEXTUAL-CONVENTION
Index of File Systems Option Name
current
FileSystemOptionsValueTC
TEXTUAL-CONVENTION
Index of File Systems Option Value
current
FileSystemResourceIndexTC
TEXTUAL-CONVENTION
Resource Number of file system resource
current
FileSystemResourceNameTC
TEXTUAL-CONVENTION
File System resource name
current
FileSystemSpaceUnitTC
TEXTUAL-CONVENTION
Units of space in the file System represented in Gigabytes
current
FileSystemStatusTC
TEXTUAL-CONVENTION
Current File System Status
current
HaStatusTC
TEXTUAL-CONVENTION
The status of a high availabiilty component.
current
HaSystemStatusTC
TEXTUAL-CONVENTION
The status of the high availabiilty system.
current
KBytesPerSecond
TEXTUAL-CONVENTION
Number of KBytes transferred per second
current
Minutes
TEXTUAL-CONVENTION
Minutes
current
MtreeListStatusTC
TEXTUAL-CONVENTION
Mtree List Status TC
current
MtreeRetentionLockStatusTC
TEXTUAL-CONVENTION
Mtree Retention Lock
current
NfsClientClientsTC
TEXTUAL-CONVENTION
NFS Clients
current
NfsClientIndexTC
TEXTUAL-CONVENTION
Index of NFS clients
current
NfsClientOptionsTC
TEXTUAL-CONVENTION
NFS options
current
NfsClientPathTC
TEXTUAL-CONVENTION
NFS path
current
NfsStatsCacheEntryTC
TEXTUAL-CONVENTION
Number of cache entries
current
NfsStatsCurrentOpenStreamsTC
TEXTUAL-CONVENTION
Number of current open streams
current
NfsStatsExportPointTC
TEXTUAL-CONVENTION
NFS export point
current
NfsStatsFileHandleLookupTC
TEXTUAL-CONVENTION
Number of file handle lookup
current
NfsStatsFilesystemTypeTC
TEXTUAL-CONVENTION
NFS file system type
current
NfsStatsIndexTC
TEXTUAL-CONVENTION
Index of NFS stats
current
NfsStatsMaxCacheSizeTC
TEXTUAL-CONVENTION
Max cache size
current
NfsStatusTC
TEXTUAL-CONVENTION
Current Network File System Status
current
NvramBatteryIndexTC
TEXTUAL-CONVENTION
Number of NVRAM Battery present in the DDR
current
NvramBatteryStatusTC
TEXTUAL-CONVENTION
Current NVRAM Battery Status Status Description -------------------------------- ok charged and enabled discharged charging and enabled
current
NvramHCPropertyBytesTC
TEXTUAL-CONVENTION
Value of an NVRAM high capacity property in bytes.
current
NvramIndexTC
TEXTUAL-CONVENTION
Index of NVRAM card present in the DDR
current
NvramMemorySizeTC
TEXTUAL-CONVENTION
Memory Size of NVRAM in bytes.
current
NvramWindowSizeTC
TEXTUAL-CONVENTION
Window Size of NVRAM in bytes.
current
OpsPerSecond
TEXTUAL-CONVENTION
Number of Operations performed per second
current
Percentage
TEXTUAL-CONVENTION
Percentage
current
PercentageStr
TEXTUAL-CONVENTION
Percentage string
current
PowerModuleDescriptionTC
TEXTUAL-CONVENTION
Power Module Description
current
PowerModuleIndexTC
TEXTUAL-CONVENTION
Number of Power Module present in the DDR
current
PowerModuleStatusTC
TEXTUAL-CONVENTION
Current Power Module Status
current
RaidDiskStateTC
TEXTUAL-CONVENTION
Raid Disk State
current
ReplicationConfigConnHostTC
TEXTUAL-CONVENTION
Replicaton Configuration Connection Host
current
ReplicationConfigConnPortTC
TEXTUAL-CONVENTION
Replicaton Configuration Connection Port
current
ReplicationConfigContextIdTC
TEXTUAL-CONVENTION
Replicaton Configuration Context Id
current
ReplicationConfigDestTC
TEXTUAL-CONVENTION
Replicaton Configuration Destination
current
ReplicationConfigEnabledTC
TEXTUAL-CONVENTION
Replication Configuration Enabled
current
ReplicationConfigIndexTC
TEXTUAL-CONVENTION
Replication Config Row Index
current
ReplicationConfigLowBWOptimTC
TEXTUAL-CONVENTION
Replication Low BW Optimization Status
current
ReplicationConfigSourceTC
TEXTUAL-CONVENTION
Replicaton Configuration Connection Source
current
ReplicationConnectTimeTC
TEXTUAL-CONVENTION
timestamp when connection was established, or 0 if there is no Replication connection
current
ReplicationContextTC
TEXTUAL-CONVENTION
0 for collection replication contexts, > 0 for directory replication contexts
current
ReplicationPathTC
TEXTUAL-CONVENTION
source or destination path for replication
current
ReplicationStateTC
TEXTUAL-CONVENTION
Current Replication status
current
ReplicationStatusTC
TEXTUAL-CONVENTION
Current Replication connection status
current
ReplicationSyncedTimeTC
TEXTUAL-CONVENTION
timestamp when replication source and destination were in sync, or 0 if unknown
current
ReplicationThrottleTC
TEXTUAL-CONVENTION
measurement of replication throttle in bps
current
ReplicationTrafficTC
TEXTUAL-CONVENTION
measurement of bytes being replicated
current
SmtStatusTC
TEXTUAL-CONVENTION
Status of the SMT feature components. They may be enabled or disabled.
current
SystemNotesTC
TEXTUAL-CONVENTION
System notes
current
SystemSerialNumberTC
TEXTUAL-CONVENTION
System Serial Number
current
SystemStatsIndexTC
TEXTUAL-CONVENTION
Statistics Row Index
current
SystemTimeZoneNameTC
TEXTUAL-CONVENTION
DDR system's time zone name
current
TempSensorDescriptionTC
TEXTUAL-CONVENTION
Temperature Sensor Description
current
TempSensorIndexTC
TEXTUAL-CONVENTION
Number of Temperature Sensor present in the DDR
current
TempSensorStatusTC
TEXTUAL-CONVENTION
Current Temperature Sensor Status
current
Temperature
TEXTUAL-CONVENTION
Temperature value in Celsius
current
TenantUnitMgmtGroupTypeTC
TEXTUAL-CONVENTION
The type of a Management group of a tenant-unit.
current
TenantUnitMgmtUserListUserRoleTC
TEXTUAL-CONVENTION
The role of a Management user of a tenant-unit. It can be tenant-admin (1) or tenant-user (2).
current
TenantUnitSecurityModeTC
TEXTUAL-CONVENTION
The security mode of a tenant-unit. It can be strict (1) or default (2).
current
VtlAdminStateTC
TEXTUAL-CONVENTION
Current VTL administration state
current
VtlDriveIndexTC
TEXTUAL-CONVENTION
Index of VTL drive
current
VtlDriveModelTC
TEXTUAL-CONVENTION
VTL drive model
current
VtlDriveNameTC
TEXTUAL-CONVENTION
VTL drive name
current
VtlDriveRevisionTC
TEXTUAL-CONVENTION
VTL drive revision
current
VtlDriveSerialTC
TEXTUAL-CONVENTION
VTL drive serial
current
VtlDriveStatusTC
TEXTUAL-CONVENTION
Current VTL drive status
current
VtlDriveTapeVolumeTC
TEXTUAL-CONVENTION
VTL drive tape volume
current
VtlDriveVendorTC
TEXTUAL-CONVENTION
VTL drive vendor
current
VtlLibraryIndexTC
TEXTUAL-CONVENTION
Index of VTL library
current
VtlLibraryModelTC
TEXTUAL-CONVENTION
VTL library model
current
VtlLibraryNameTC
TEXTUAL-CONVENTION
VTL library name
current
VtlLibraryRevisionTC
TEXTUAL-CONVENTION
VTL library revision
current
VtlLibrarySerialTC
TEXTUAL-CONVENTION
VTL library serial
current
VtlLibraryStatusTC
TEXTUAL-CONVENTION
Current VTL library status
current
VtlLibraryTotalCapsTC
TEXTUAL-CONVENTION
Number of VTL caps
current
VtlLibraryTotalDrivesTC
TEXTUAL-CONVENTION
Number of VTL drives
current
VtlLibraryTotalSlotsTC
TEXTUAL-CONVENTION
Number of VTL slots
current
VtlLibraryVendorTC
TEXTUAL-CONVENTION
VTL library vendor
current
VtlPortConnectionTypeTC
TEXTUAL-CONVENTION
VTL Port Connection Type
current
VtlPortEnabledTC
TEXTUAL-CONVENTION
VTL Port Enabled
current
VtlPortFirmwareTC
TEXTUAL-CONVENTION
VTL Port Firmware
current
VtlPortIDTC
TEXTUAL-CONVENTION
VTL Port Id
current
VtlPortIndexTC
TEXTUAL-CONVENTION
VTL Port Table Index
current
VtlPortModelTC
TEXTUAL-CONVENTION
VTL Port MODEL
current
VtlPortNameTC
TEXTUAL-CONVENTION
VTL Port Name
current
VtlPortSpeedTC
TEXTUAL-CONVENTION
VTL Port Speed
current
VtlPortStatusTC
TEXTUAL-CONVENTION
VTL Port State
current
VtlPortWWNNTC
TEXTUAL-CONVENTION
VTL WWNN Address
current
VtlPortWWPNTC
TEXTUAL-CONVENTION
VTL WWPN Address
current
VtlProcessStateTC
TEXTUAL-CONVENTION
Current VTL process state
current
VtlStatsConrolCommandsTC
TEXTUAL-CONVENTION
VTL Stats Table Control Commands
current
VtlStatsInTC
TEXTUAL-CONVENTION
VTL Stats Table Stats In
current
VtlStatsIndexTC
TEXTUAL-CONVENTION
VTL Stats Table Index
current
VtlStatsInvalidCRCsTC
TEXTUAL-CONVENTION
VTL Stats Table Invalid CRCs
current
VtlStatsInvalidTxWordsTC
TEXTUAL-CONVENTION
VTL Stats Table Invalid Tx Words
current
VtlStatsLIPCountTC
TEXTUAL-CONVENTION
VTL Stats Table LIP count
current
VtlStatsLinkFailuresTC
TEXTUAL-CONVENTION
VTL Stats Table Link failures
current
VtlStatsOutTC
TEXTUAL-CONVENTION
VTL Stats Table Stats Out
current
VtlStatsPortTC
TEXTUAL-CONVENTION
VTL Tape Bar Code
current
VtlStatsPrimSeqProtoErrorsTC
TEXTUAL-CONVENTION
VTL Stats Table Prim Seq Protocol Errors
current
VtlStatsReadCommandsTC
TEXTUAL-CONVENTION
VTL Stats Table Read Commands
current
VtlStatsSignalLossesTC
TEXTUAL-CONVENTION
VTL Stats Table Signal Losses
current
VtlStatsSyncLossesTC
TEXTUAL-CONVENTION
VTL Stats Table Sync Losses
current
VtlStatsWriteCommandsTC
TEXTUAL-CONVENTION
VTL Stats Table write commands
current
VtlTapeBarCodeTC
TEXTUAL-CONVENTION
VTL Tape Bar Code
current
VtlTapeCompTC
TEXTUAL-CONVENTION
VTL Tape Compression
current
VtlTapeIndexTC
TEXTUAL-CONVENTION
VTL Tape Table Index
current
VtlTapeLocationTC
TEXTUAL-CONVENTION
VTL Tape Location
current
VtlTapeModTimeTC
TEXTUAL-CONVENTION
VTL Tape Mod Time
current
VtlTapePoolTC
TEXTUAL-CONVENTION
VTL Tape Pool
current
VtlTapeSizeTC
TEXTUAL-CONVENTION
VTL Tape Size
current
VtlTapeStateTC
TEXTUAL-CONVENTION
VTL Tape State
current
VtlTapeUsedTC
TEXTUAL-CONVENTION
VTL Tape Used
current

Objects

NameOIDSyntaxAccessStatus
dataDomainMibConformance
OBJECT-IDENTITY
1.3.6.1.4.1.19746.0
dataDomainMibCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.19746.0.1
dataDomainMibGroups
OBJECT-IDENTITY
1.3.6.1.4.1.19746.0.2
dataDomainMibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1
environmentals
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1
power
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1.1
powerModules
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1.1.1
powerModuleTable
OBJECT-TYPE
A table containing entries of PowerModuleEntry.
1.3.6.1.4.1.19746.1.1.1.1.1not-accessiblecurrent
powerModuleEntry
OBJECT-TYPE
powerModuleTable Row Description
1.3.6.1.4.1.19746.1.1.1.1.1.1not-accessiblecurrent
powerEnclosureID
OBJECT-TYPE
Power Module Enclosure ID
1.3.6.1.4.1.19746.1.1.1.1.1.1.1EnclosureIDnot-accessiblecurrent
powerModuleIndex
OBJECT-TYPE
Power Module index
1.3.6.1.4.1.19746.1.1.1.1.1.1.2PowerModuleIndexTCnot-accessiblecurrent
powerModuleDescription
OBJECT-TYPE
Power Module Description
1.3.6.1.4.1.19746.1.1.1.1.1.1.3PowerModuleDescriptionTCread-onlycurrent
powerModuleStatus
OBJECT-TYPE
current enclosure Power Module status
1.3.6.1.4.1.19746.1.1.1.1.1.1.4PowerModuleStatusTCread-onlycurrent
temperatures
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1.2
temperatureSensors
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1.2.1
temperatureSensorTable
OBJECT-TYPE
A table containing entries of TemperatureSensorEntry.
1.3.6.1.4.1.19746.1.1.2.1.1not-accessiblecurrent
temperatureSensorEntry
OBJECT-TYPE
temperatureSensorTable Row Description
1.3.6.1.4.1.19746.1.1.2.1.1.1not-accessiblecurrent
tempEnclosureID
OBJECT-TYPE
Temperature Sensor Enclosure ID
1.3.6.1.4.1.19746.1.1.2.1.1.1.1EnclosureIDnot-accessiblecurrent
tempSensorIndex
OBJECT-TYPE
Temperature Sensor Number
1.3.6.1.4.1.19746.1.1.2.1.1.1.2TempSensorIndexTCnot-accessiblecurrent
tempSensorTrapIndex
OBJECT-TYPE
Temperature Sensor Number Used for Traps
1.3.6.1.4.1.19746.1.1.2.1.1.1.3TempSensorIndexTCread-onlycurrent
tempSensorDescription
OBJECT-TYPE
Temperature Sensor Description
1.3.6.1.4.1.19746.1.1.2.1.1.1.4TempSensorDescriptionTCread-onlycurrent
tempSensorCurrentValue
OBJECT-TYPE
Current Temperature Value of the sensor
1.3.6.1.4.1.19746.1.1.2.1.1.1.5Temperatureread-onlycurrent
tempSensorStatus
OBJECT-TYPE
Current status of the sensor
1.3.6.1.4.1.19746.1.1.2.1.1.1.6TempSensorStatusTCread-onlycurrent
fans
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1.3
fanProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.1.3.1
fanPropertiesTable
OBJECT-TYPE
A table containing entries of FanPropertiesEntry.
1.3.6.1.4.1.19746.1.1.3.1.1not-accessiblecurrent
fanPropertiesEntry
OBJECT-TYPE
fanPropertiesTable Row Description
1.3.6.1.4.1.19746.1.1.3.1.1.1not-accessiblecurrent
fanEnclosureID
OBJECT-TYPE
Enclosure ID of fan
1.3.6.1.4.1.19746.1.1.3.1.1.1.1EnclosureIDnot-accessiblecurrent
fanIndex
OBJECT-TYPE
Fan Number Index of the fan
1.3.6.1.4.1.19746.1.1.3.1.1.1.2FanIndexTCnot-accessiblecurrent
fanTrapIndex
OBJECT-TYPE
Fan Number trap index, used for trap notifications
1.3.6.1.4.1.19746.1.1.3.1.1.1.3FanIndexTCread-onlycurrent
fanDescription
OBJECT-TYPE
Vendor supplied description of the fan
1.3.6.1.4.1.19746.1.1.3.1.1.1.4FanDescriptionTCread-onlycurrent
fanLevel
OBJECT-TYPE
current run level of fan
1.3.6.1.4.1.19746.1.1.3.1.1.1.5FanLevelTCread-onlycurrent
fanStatus
OBJECT-TYPE
Current status of the fan
1.3.6.1.4.1.19746.1.1.3.1.1.1.6FanStatusTCread-onlycurrent
nvram
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.2
nvramProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.2.1
nvramPropertiesTable
OBJECT-TYPE
A table containing entries of NvramPropertiesEntry.
1.3.6.1.4.1.19746.1.2.1.1not-accessiblecurrent
nvramPropertiesEntry
OBJECT-TYPE
nvramPropertiesTable Row Description
1.3.6.1.4.1.19746.1.2.1.1.1not-accessiblecurrent
nvramPropertiesIndex
OBJECT-TYPE
NVRAM card index
1.3.6.1.4.1.19746.1.2.1.1.1.1NvramIndexTCnot-accessiblecurrent
nvramMemorySize
OBJECT-TYPE
Size of NVRAM Memory in bytes
1.3.6.1.4.1.19746.1.2.1.1.1.2NvramMemorySizeTCread-onlycurrent
nvramWindowSize
OBJECT-TYPE
Window size of NVRAM in bytes
1.3.6.1.4.1.19746.1.2.1.1.1.3NvramWindowSizeTCread-onlycurrent
nvramHCMemorySize
OBJECT-TYPE
The size of an NVRAM entity's memory in bytes, with support for high capacity modules. This entry may be used in place of nvramMemorySize.
1.3.6.1.4.1.19746.1.2.1.1.1.4NvramHCPropertyBytesTCread-onlycurrent
nvramStats
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.2.2
nvramStatsTable
OBJECT-TYPE
A table containing entries of NvramStatsEntry.
1.3.6.1.4.1.19746.1.2.2.1not-accessiblecurrent
nvramStatsEntry
OBJECT-TYPE
nvramStatsTable Row Description
1.3.6.1.4.1.19746.1.2.2.1.1not-accessiblecurrent
nvramStatsIndex
OBJECT-TYPE
NVRAM card index
1.3.6.1.4.1.19746.1.2.2.1.1.1NvramIndexTCnot-accessiblecurrent
nvramPCIErrorCount
OBJECT-TYPE
Number of PCI Errors Encountered on NVRAM Card
1.3.6.1.4.1.19746.1.2.2.1.1.2ErrorCountread-onlycurrent
nvramMemoryErrorCount
OBJECT-TYPE
Number of Memory Errors Encountered on NVRAM Card
1.3.6.1.4.1.19746.1.2.2.1.1.3ErrorCountread-onlycurrent
nvramBatteries
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.2.3
nvramBatteryTable
OBJECT-TYPE
A table containing entries of NvramBatteryEntry.
1.3.6.1.4.1.19746.1.2.3.1not-accessiblecurrent
nvramBatteryEntry
OBJECT-TYPE
nvramBatteryTable Row Description
1.3.6.1.4.1.19746.1.2.3.1.1not-accessiblecurrent
nvramBatteriesIndex
OBJECT-TYPE
NVRAM card index
1.3.6.1.4.1.19746.1.2.3.1.1.1NvramIndexTCnot-accessiblecurrent
nvramBatteryIndex
OBJECT-TYPE
NVRAM Battery Number
1.3.6.1.4.1.19746.1.2.3.1.1.2NvramBatteryIndexTCnot-accessiblecurrent
nvramBatteryStatus
OBJECT-TYPE
NVRAM Battery Status
1.3.6.1.4.1.19746.1.2.3.1.1.3NvramBatteryStatusTCread-onlycurrent
nvramBatteryCharge
OBJECT-TYPE
NVRAM Battery charge percentage
1.3.6.1.4.1.19746.1.2.3.1.1.4Percentageread-onlycurrent
fileSystem
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3
fileSystemProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3.1
fileSystemStatus
OBJECT-TYPE
Status of the file system
1.3.6.1.4.1.19746.1.3.1.1FileSystemStatusTCread-onlycurrent
fileSystemVirtualSpace
OBJECT-TYPE
Amount of Uncompressed data that has been backed up by the system
1.3.6.1.4.1.19746.1.3.1.2FileSystemSpaceUnitTCread-onlycurrent
fileSystemUpTime
OBJECT-TYPE
File System Up time
1.3.6.1.4.1.19746.1.3.1.3DDMibTimeStampTCread-onlycurrent
fileSystemStatusMessage
OBJECT-TYPE
file system status message
1.3.6.1.4.1.19746.1.3.1.4DDMibTableString256TCread-onlycurrent
fileSystemSpace
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3.2
fileSystemSpaceTable
OBJECT-TYPE
A table containing entries of FileSystemSpaceEntry.
1.3.6.1.4.1.19746.1.3.2.1not-accessiblecurrent
fileSystemSpaceEntry
OBJECT-TYPE
fileSystemSpaceTable Row Description
1.3.6.1.4.1.19746.1.3.2.1.1not-accessiblecurrent
fileSystemResourceIndex
OBJECT-TYPE
File system resource index
1.3.6.1.4.1.19746.1.3.2.1.1.1FileSystemResourceIndexTCnot-accessiblecurrent
fileSystemResourceTrapIndex
OBJECT-TYPE
File system resource trap index
1.3.6.1.4.1.19746.1.3.2.1.1.2FileSystemResourceIndexTCread-onlycurrent
fileSystemResourceName
OBJECT-TYPE
File system resource name
1.3.6.1.4.1.19746.1.3.2.1.1.3FileSystemResourceNameTCread-onlycurrent
fileSystemSpaceSize
OBJECT-TYPE
Size of the file system resource in gigabytes
1.3.6.1.4.1.19746.1.3.2.1.1.4FileSystemSpaceUnitTCread-onlycurrent
fileSystemSpaceUsed
OBJECT-TYPE
Amount of used space within the file system resource in gigabytes
1.3.6.1.4.1.19746.1.3.2.1.1.5FileSystemSpaceUnitTCread-onlycurrent
fileSystemSpaceAvail
OBJECT-TYPE
Amount of available space within the file system resource in gigabytes
1.3.6.1.4.1.19746.1.3.2.1.1.6FileSystemSpaceUnitTCread-onlycurrent
fileSystemPercentUsed
OBJECT-TYPE
Percentage of used space within the file system resource
1.3.6.1.4.1.19746.1.3.2.1.1.7Percentageread-onlycurrent
fileSystemSpaceCleanable
OBJECT-TYPE
Amount of cleanable space within the file system resource
1.3.6.1.4.1.19746.1.3.2.1.1.8FileSystemSpaceUnitTCread-onlycurrent
fileSystemResourceTier
OBJECT-TYPE
The tier that a resource belongs to, such as active or archive.
1.3.6.1.4.1.19746.1.3.2.1.1.9DDMibTableString128TCread-onlycurrent
fileSystemCompression
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3.3
fileSystemCompressionTable
OBJECT-TYPE
A table containing entries of FileSystemCompressionEntry.
1.3.6.1.4.1.19746.1.3.3.1not-accessiblecurrent
fileSystemCompressionEntry
OBJECT-TYPE
fileSystemCompressionTable Row Description
1.3.6.1.4.1.19746.1.3.3.1.1not-accessiblecurrent
fileSystemCompressionIndex
OBJECT-TYPE
File system compression index
1.3.6.1.4.1.19746.1.3.3.1.1.1FileSystemResourceIndexTCnot-accessiblecurrent
fileSystemCompressionPeriod
OBJECT-TYPE
File system compression period
1.3.6.1.4.1.19746.1.3.3.1.1.2FileSystemCompressionPeriodTCread-onlycurrent
fileSystemCompressionStartTime
OBJECT-TYPE
File system compression start time
1.3.6.1.4.1.19746.1.3.3.1.1.3DateTCread-onlycurrent
fileSystemCompressionEndTime
OBJECT-TYPE
File system compression end time
1.3.6.1.4.1.19746.1.3.3.1.1.4DateTCread-onlycurrent
fileSystemPreCompressionSize
OBJECT-TYPE
Size of the file system pre compression in gigabytes
1.3.6.1.4.1.19746.1.3.3.1.1.5FileSystemCompressionSizeTCread-onlycurrent
fileSystemPostCompressionSize
OBJECT-TYPE
Size of the file system post compression in gigabytes
1.3.6.1.4.1.19746.1.3.3.1.1.6FileSystemCompressionSizeTCread-onlycurrent
fileSystemGlobalCompressionFactor
OBJECT-TYPE
File system global compression factor
1.3.6.1.4.1.19746.1.3.3.1.1.7FileSystemCompressionFactorTCread-onlycurrent
fileSystemLocalCompressionFactor
OBJECT-TYPE
File system local compression factor
1.3.6.1.4.1.19746.1.3.3.1.1.8FileSystemCompressionFactorTCread-onlycurrent
fileSystemTotalCompressionFactor
OBJECT-TYPE
File system Total compression factor
1.3.6.1.4.1.19746.1.3.3.1.1.9FileSystemCompressionFactorTCread-onlycurrent
fileSystemReductionPercent
OBJECT-TYPE
File system Reduction Percent
1.3.6.1.4.1.19746.1.3.3.1.1.10Percentageread-onlydeprecated
fileSystemReductionPercent1
OBJECT-TYPE
File system Reduction Percent
1.3.6.1.4.1.19746.1.3.3.1.1.11PercentageStrread-onlycurrent
fileSystemOptions
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3.4
fileSystemOptionsTable
OBJECT-TYPE
A table containing entries of fileSystemOptionsEntry.
1.3.6.1.4.1.19746.1.3.4.1not-accessiblecurrent
fileSystemOptionsEntry
OBJECT-TYPE
fileSystemOptionsTable Row Description
1.3.6.1.4.1.19746.1.3.4.1.1not-accessiblecurrent
fileSystemOptionsIndex
OBJECT-TYPE
fileSystem Options index
1.3.6.1.4.1.19746.1.3.4.1.1.1FileSystemOptionsIndexTCnot-accessiblecurrent
fileSystemOptionsName
OBJECT-TYPE
This object represents the fileSystem Options type in text format. Below lists the possible options and their representations. -------------------------------- -------------------------- Option Name Representation in text -------------------------------- -------------------------- Local compression type gz/gzfast/lz Marker-type auto/cv1 Report-replica-as-writable enabled/disabled Low-bw-optim replication support enabled/disabled Current global compression type 1/9 Staging reserve % of the total space/disabled Staging clean % of staging reserve space Staging delete suspend % of staging reserve space -------------------------------- ---------------------------
1.3.6.1.4.1.19746.1.3.4.1.1.2FileSystemOptionsNameTCread-onlycurrent
fileSystemOptionsValue
OBJECT-TYPE
fileSystem Options Value
1.3.6.1.4.1.19746.1.3.4.1.1.3FileSystemOptionsValueTCread-onlycurrent
fileSystemClean
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3.5
fileSystemCleanTable
OBJECT-TYPE
A table containing entries of fileSystemCleanEntry.
1.3.6.1.4.1.19746.1.3.5.1not-accessiblecurrent
fileSystemCleanEntry
OBJECT-TYPE
fileSystemCleanTable Row Description
1.3.6.1.4.1.19746.1.3.5.1.1not-accessiblecurrent
fileSystemCleanIndex
OBJECT-TYPE
fileSystem Clean index
1.3.6.1.4.1.19746.1.3.5.1.1.1FileSystemCleanIndexTCnot-accessiblecurrent
fileSystemCleanStatus
OBJECT-TYPE
fileSystem Clean Status
1.3.6.1.4.1.19746.1.3.5.1.1.2FileSystemCleanStatusTCread-onlycurrent
fileSystemCleanSchedule
OBJECT-TYPE
fileSystem Clean Schedule
1.3.6.1.4.1.19746.1.3.5.1.1.3FileSystemCleanScheduleTCread-onlycurrent
fileSystemCleanThrottle
OBJECT-TYPE
fileSystem Clean Throttle
1.3.6.1.4.1.19746.1.3.5.1.1.4FileSystemCleanThrottleTCread-onlycurrent
fileSystemArchiveUnit
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.3.6
fileSystemArchiveUnitTable
OBJECT-TYPE
A table containing entries of fileSystemArchiveUnitEntry.
1.3.6.1.4.1.19746.1.3.6.1not-accessiblecurrent
fileSystemArchiveUnitEntry
OBJECT-TYPE
fileSystemArchiveUnitTable Row Description
1.3.6.1.4.1.19746.1.3.6.1.1not-accessiblecurrent
fileSystemArchiveUnitIndex
OBJECT-TYPE
fileSystem ArchiveUnit index
1.3.6.1.4.1.19746.1.3.6.1.1.1DDMibTableIndexTCnot-accessiblecurrent
fileSystemArchiveUnitName
OBJECT-TYPE
fileSystem ArchiveUnit Name
1.3.6.1.4.1.19746.1.3.6.1.1.2DDMibTableString256TCread-onlycurrent
fileSystemArchiveUnitState
OBJECT-TYPE
fileSystem ArchiveUnit State
1.3.6.1.4.1.19746.1.3.6.1.1.3FileSystemArchiveUnitStateTCread-onlycurrent
fileSystemArchiveUnitStatus
OBJECT-TYPE
fileSystem ArchiveUnit Status
1.3.6.1.4.1.19746.1.3.6.1.1.4FileSystemArchiveUnitStatusTCread-onlycurrent
fileSystemArchiveUnitStartTime
OBJECT-TYPE
fileSystem ArchiveUnit start Time
1.3.6.1.4.1.19746.1.3.6.1.1.5DDMibTimeStampTCread-onlycurrent
fileSystemArchiveUnitEndTime
OBJECT-TYPE
fileSystem ArchiveUnit End Time
1.3.6.1.4.1.19746.1.3.6.1.1.6DDMibTimeStampTCread-onlycurrent
fileSystemArchiveUnitSize
OBJECT-TYPE
fileSystem ArchiveUnit Size in Gib
1.3.6.1.4.1.19746.1.3.6.1.1.7DDMibTableSizeGibTCread-onlycurrent
fileSystemArchiveUnitDiskGroups
OBJECT-TYPE
fileSystem ArchiveUnit DiskGroups
1.3.6.1.4.1.19746.1.3.6.1.1.8DDMibTableString1024TCread-onlycurrent
alerts
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.4
currentAlerts
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.4.1
currentAlertTable
OBJECT-TYPE
A table containing entries of CurrentAlertEntry.
1.3.6.1.4.1.19746.1.4.1.1not-accessiblecurrent
currentAlertEntry
OBJECT-TYPE
currentAlertTable Row Description
1.3.6.1.4.1.19746.1.4.1.1.1not-accessiblecurrent
currentAlertIndex
OBJECT-TYPE
Current Alert Row index
1.3.6.1.4.1.19746.1.4.1.1.1.1AlertIndexTCnot-accessiblecurrent
currentAlertTimestamp
OBJECT-TYPE
Timestamp of current alert
1.3.6.1.4.1.19746.1.4.1.1.1.2AlertTimestampTCread-onlycurrent
currentAlertDescription
OBJECT-TYPE
Alert Description
1.3.6.1.4.1.19746.1.4.1.1.1.3AlertDescriptionTCread-onlycurrent
currentAlertSeverity
OBJECT-TYPE
Alert Severity
1.3.6.1.4.1.19746.1.4.1.1.1.4DDMibAlertSeverityTCread-onlycurrent
currentAlertID
OBJECT-TYPE
Alert ID
1.3.6.1.4.1.19746.1.4.1.1.1.5DDMibTableString32TCread-onlycurrent
alertHistory
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.4.2
alertHistoryTable
OBJECT-TYPE
A table containing entries of Alert History Entries.
1.3.6.1.4.1.19746.1.4.2.1not-accessiblecurrent
alertHistoryEntry
OBJECT-TYPE
alertHistoryTable Row Description
1.3.6.1.4.1.19746.1.4.2.1.1not-accessiblecurrent
alertHistoryIndex
OBJECT-TYPE
Alert History Row index
1.3.6.1.4.1.19746.1.4.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
alertHistoryTimestamp
OBJECT-TYPE
Timestamp of alert
1.3.6.1.4.1.19746.1.4.2.1.1.2DDMibTimeStampTCread-onlycurrent
alertHistoryDescription
OBJECT-TYPE
Alert history Description
1.3.6.1.4.1.19746.1.4.2.1.1.3DDMibTableString256TCread-onlycurrent
alertHistorySeverity
OBJECT-TYPE
Alert history Severity
1.3.6.1.4.1.19746.1.4.2.1.1.4DDMibAlertSeverityTCread-onlycurrent
alertHistoryStatus
OBJECT-TYPE
Alert history Status (Post or Cleared)
1.3.6.1.4.1.19746.1.4.2.1.1.5DDMibTableString64TCread-onlycurrent
alertInfo
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.4.3
alertInfoTable
OBJECT-TYPE
A table containing entries of Alert Information.
1.3.6.1.4.1.19746.1.4.3.1not-accessiblecurrent
alertInfoEntry
OBJECT-TYPE
alertInfoTable Row Description
1.3.6.1.4.1.19746.1.4.3.1.1not-accessiblecurrent
alertInfoIndex
OBJECT-TYPE
Alert Info Row index
1.3.6.1.4.1.19746.1.4.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
alertInfoDescription
OBJECT-TYPE
Alert Info Description
1.3.6.1.4.1.19746.1.4.3.1.1.2DDMibTableString256TCread-onlycurrent
statistics
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.5
systemStats
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.5.1
systemStatsTable
OBJECT-TYPE
A table containing entries of SystemStatsEntry.
1.3.6.1.4.1.19746.1.5.1.1not-accessiblecurrent
systemStatsEntry
OBJECT-TYPE
systemStatsTable Row Description
1.3.6.1.4.1.19746.1.5.1.1.1not-accessiblecurrent
systemStatsIndex
OBJECT-TYPE
System Stats Row index
1.3.6.1.4.1.19746.1.5.1.1.1.1SystemStatsIndexTCnot-accessiblecurrent
cpuAvgPercentageBusy
OBJECT-TYPE
CPU Average Percentage Busy
1.3.6.1.4.1.19746.1.5.1.1.1.2Percentageread-onlycurrent
cpuMaxPercentageBusy
OBJECT-TYPE
CPU Max Percentage Busy
1.3.6.1.4.1.19746.1.5.1.1.1.3Percentageread-onlycurrent
nfsOpsPerSecond
OBJECT-TYPE
Number of NFS Operations performed per second
1.3.6.1.4.1.19746.1.5.1.1.1.4OpsPerSecondread-onlycurrent
nfsIdlePercentage
OBJECT-TYPE
Percentage of time NFS was Idle
1.3.6.1.4.1.19746.1.5.1.1.1.5Percentageread-onlycurrent
nfsProcPercentage
OBJECT-TYPE
Percentage of time NFS was processing
1.3.6.1.4.1.19746.1.5.1.1.1.6Percentageread-onlycurrent
nfsSendPercentage
OBJECT-TYPE
Percentage of time NFS was sending requests
1.3.6.1.4.1.19746.1.5.1.1.1.7Percentageread-onlycurrent
nfsReceivePercentage
OBJECT-TYPE
Percentage of time NFS was receiving requests
1.3.6.1.4.1.19746.1.5.1.1.1.8Percentageread-onlycurrent
cifsOpsPerSecond
OBJECT-TYPE
Number of CIFS Operations performed per second
1.3.6.1.4.1.19746.1.5.1.1.1.9OpsPerSecondread-onlycurrent
diskReadKBytesPerSecond
OBJECT-TYPE
Number of KBytes per second read from disk
1.3.6.1.4.1.19746.1.5.1.1.1.10KBytesPerSecondread-onlycurrent
diskWriteKBytesPerSecond
OBJECT-TYPE
Number of KBytes per second written on disk
1.3.6.1.4.1.19746.1.5.1.1.1.11KBytesPerSecondread-onlycurrent
diskBusyPercentage
OBJECT-TYPE
Percentage of Time Disks were busy
1.3.6.1.4.1.19746.1.5.1.1.1.12Percentageread-onlycurrent
nvramReadKBytesPerSecond
OBJECT-TYPE
Number of KBytes read per second from NVRAM
1.3.6.1.4.1.19746.1.5.1.1.1.13KBytesPerSecondread-onlycurrent
nvramWriteKBytesPerSecond
OBJECT-TYPE
Number of KBytes written per second on NVRAM
1.3.6.1.4.1.19746.1.5.1.1.1.14KBytesPerSecondread-onlycurrent
replInKBytesPerSecond
OBJECT-TYPE
Number of KBytes per second received for Replication
1.3.6.1.4.1.19746.1.5.1.1.1.15KBytesPerSecondread-onlycurrent
replOutKBytesPerSecond
OBJECT-TYPE
Number of KBytes per second sent for Replication
1.3.6.1.4.1.19746.1.5.1.1.1.16KBytesPerSecondread-onlycurrent
diskStorage
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.6
diskProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.6.1
diskPropertiesTable
OBJECT-TYPE
A table containing entries of DiskPropertiesEntry.
1.3.6.1.4.1.19746.1.6.1.1not-accessiblecurrent
diskPropertiesEntry
OBJECT-TYPE
diskPropertiesTable Row Description
1.3.6.1.4.1.19746.1.6.1.1.1not-accessiblecurrent
diskPropEnclosureID
OBJECT-TYPE
Enclosure ID of disk
1.3.6.1.4.1.19746.1.6.1.1.1.1EnclosureIDnot-accessiblecurrent
diskPropIndex
OBJECT-TYPE
Disk Number
1.3.6.1.4.1.19746.1.6.1.1.1.2DiskIndexTCnot-accessiblecurrent
diskPropTrapIndex
OBJECT-TYPE
Disk Number for Traps
1.3.6.1.4.1.19746.1.6.1.1.1.3DiskIndexTCread-onlycurrent
diskModel
OBJECT-TYPE
Manufacture and model of the disk
1.3.6.1.4.1.19746.1.6.1.1.1.4DiskModelTCread-onlycurrent
diskFirmwareVersion
OBJECT-TYPE
Firmware version of the disk
1.3.6.1.4.1.19746.1.6.1.1.1.5DiskFirmwareVersionTCread-onlycurrent
diskSerialNumber
OBJECT-TYPE
Serial Number of the disk
1.3.6.1.4.1.19746.1.6.1.1.1.6DiskSerialNumberTCread-onlycurrent
diskCapacity
OBJECT-TYPE
Capacity of the disk
1.3.6.1.4.1.19746.1.6.1.1.1.7DiskCapacityTCread-onlycurrent
diskPropState
OBJECT-TYPE
Current State of the disk
1.3.6.1.4.1.19746.1.6.1.1.1.8DiskStateTCread-onlycurrent
diskPack
OBJECT-TYPE
Pack information of the disk. Applicable to enclosures with packs such as ES60, and not for ES20 or ES30.
1.3.6.1.4.1.19746.1.6.1.1.1.9DiskPackTCread-onlycurrent
diskPerformance
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.6.2
diskPerformanceTable
OBJECT-TYPE
A table containing entries of DiskPerformanceEntry.
1.3.6.1.4.1.19746.1.6.2.1not-accessiblecurrent
diskPerformanceEntry
OBJECT-TYPE
diskPerformanceTable Row Description
1.3.6.1.4.1.19746.1.6.2.1.1not-accessiblecurrent
diskPerfEnclosureID
OBJECT-TYPE
Enclosure ID of disk
1.3.6.1.4.1.19746.1.6.2.1.1.1EnclosureIDnot-accessiblecurrent
diskPerfIndex
OBJECT-TYPE
Disk Number
1.3.6.1.4.1.19746.1.6.2.1.1.2DiskIndexTCnot-accessiblecurrent
diskSectorsRead
OBJECT-TYPE
Number of disk sectors read per second
1.3.6.1.4.1.19746.1.6.2.1.1.3DiskSectorsPerSecondTCread-onlycurrent
diskSectorsWritten
OBJECT-TYPE
Number of disk sectors written per second
1.3.6.1.4.1.19746.1.6.2.1.1.4DiskSectorsPerSecondTCread-onlycurrent
diskTotalKBytes
OBJECT-TYPE
Total Number of Kilo-bytes read/written per second
1.3.6.1.4.1.19746.1.6.2.1.1.5KBytesPerSecondread-onlycurrent
diskBusy
OBJECT-TYPE
Percentage of time disk is busy
1.3.6.1.4.1.19746.1.6.2.1.1.6Percentageread-onlycurrent
diskPerfState
OBJECT-TYPE
Current State of the disk
1.3.6.1.4.1.19746.1.6.2.1.1.7DiskStateTCread-onlycurrent
diskReliability
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.6.3
diskReliabilityTable
OBJECT-TYPE
A table containing entries of DiskReliabilityEntry.
1.3.6.1.4.1.19746.1.6.3.1not-accessiblecurrent
diskReliabilityEntry
OBJECT-TYPE
diskReliabilityTable Row Description
1.3.6.1.4.1.19746.1.6.3.1.1not-accessiblecurrent
diskErrEnclosureID
OBJECT-TYPE
Enclosure ID of disk
1.3.6.1.4.1.19746.1.6.3.1.1.1EnclosureIDnot-accessiblecurrent
diskErrIndex
OBJECT-TYPE
Disk Number
1.3.6.1.4.1.19746.1.6.3.1.1.2DiskIndexTCnot-accessiblecurrent
diskErrTrapIndex
OBJECT-TYPE
Disk Number for Traps
1.3.6.1.4.1.19746.1.6.3.1.1.3DiskIndexTCread-onlycurrent
diskTemperature
OBJECT-TYPE
Current Disk Temperature in Celsius
1.3.6.1.4.1.19746.1.6.3.1.1.4Temperatureread-onlycurrent
diskTimeoutCount
OBJECT-TYPE
Number of command timeouts
1.3.6.1.4.1.19746.1.6.3.1.1.5ErrorCountread-onlycurrent
diskReadFailCount
OBJECT-TYPE
Number of read failures
1.3.6.1.4.1.19746.1.6.3.1.1.6ErrorCountread-onlycurrent
diskWriteFailCount
OBJECT-TYPE
Number of write failures
1.3.6.1.4.1.19746.1.6.3.1.1.7ErrorCountread-onlycurrent
diskMiscFailCount
OBJECT-TYPE
Number of miscellaneous failures
1.3.6.1.4.1.19746.1.6.3.1.1.8ErrorCountread-onlycurrent
diskOffTrackErrCount
OBJECT-TYPE
Number of offtrack errors
1.3.6.1.4.1.19746.1.6.3.1.1.9ErrorCountread-onlycurrent
diskSoftEccCount
OBJECT-TYPE
Number of soft ecc errors
1.3.6.1.4.1.19746.1.6.3.1.1.10ErrorCountread-onlycurrent
diskCrcErrCount
OBJECT-TYPE
Number of crc errors
1.3.6.1.4.1.19746.1.6.3.1.1.11ErrorCountread-onlycurrent
diskProbationalCount
OBJECT-TYPE
Number of probational errors
1.3.6.1.4.1.19746.1.6.3.1.1.12ErrorCountread-onlycurrent
diskReallocCount
OBJECT-TYPE
Number of reallocation errors
1.3.6.1.4.1.19746.1.6.3.1.1.13ErrorCountread-onlycurrent
diskErrState
OBJECT-TYPE
Current State of the disk
1.3.6.1.4.1.19746.1.6.3.1.1.14DiskStateTCread-onlycurrent
replication
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.8
replicationInfo
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.8.1
replicationInfoTable
OBJECT-TYPE
A table containing entries of ReplicationInfoEntry.
1.3.6.1.4.1.19746.1.8.1.1not-accessiblecurrent
replicationInfoEntry
OBJECT-TYPE
replicationInfoTable Row Description
1.3.6.1.4.1.19746.1.8.1.1.1not-accessiblecurrent
replContext
OBJECT-TYPE
context ID of replication source/dest pair
1.3.6.1.4.1.19746.1.8.1.1.1.1ReplicationContextTCnot-accessiblecurrent
replTrapContext
OBJECT-TYPE
context ID of replication source/dest pair for traps
1.3.6.1.4.1.19746.1.8.1.1.1.2ReplicationContextTCread-onlycurrent
replState
OBJECT-TYPE
state of replication source/dest pair
1.3.6.1.4.1.19746.1.8.1.1.1.3ReplicationStateTCread-onlycurrent
replStatus
OBJECT-TYPE
status of replication source/dest pair connection
1.3.6.1.4.1.19746.1.8.1.1.1.4ReplicationStatusTCread-onlycurrent
replFileSysStatus
OBJECT-TYPE
status of filesystem
1.3.6.1.4.1.19746.1.8.1.1.1.5FileSystemStatusTCread-onlycurrent
replConnTime
OBJECT-TYPE
time of connection established between source and dest, or time since disconnect if status is 'disconnected'
1.3.6.1.4.1.19746.1.8.1.1.1.6ReplicationConnectTimeTCread-onlycurrent
replSource
OBJECT-TYPE
network path to replication source directory
1.3.6.1.4.1.19746.1.8.1.1.1.7ReplicationPathTCread-onlycurrent
replDestination
OBJECT-TYPE
network path to replication destination directory
1.3.6.1.4.1.19746.1.8.1.1.1.8ReplicationPathTCread-onlycurrent
replPreCompBytesSent
OBJECT-TYPE
pre compression bytes sent
1.3.6.1.4.1.19746.1.8.1.1.1.9ReplicationTrafficTCread-onlycurrent
replPostCompBytesSent
OBJECT-TYPE
post compression bytes sent
1.3.6.1.4.1.19746.1.8.1.1.1.10ReplicationTrafficTCread-onlycurrent
replPreCompBytesRemaining
OBJECT-TYPE
pre compression bytes remaining
1.3.6.1.4.1.19746.1.8.1.1.1.11ReplicationTrafficTCread-onlycurrent
replPostCompBytesReceived
OBJECT-TYPE
post compression bytes received
1.3.6.1.4.1.19746.1.8.1.1.1.12ReplicationTrafficTCread-onlycurrent
replThrottle
OBJECT-TYPE
replication throttle in bps -- -1 is disabled, 0 unlimited
1.3.6.1.4.1.19746.1.8.1.1.1.13ReplicationThrottleTCread-onlycurrent
replSyncedAsOfTime
OBJECT-TYPE
time when the source and destination were in sync, or 0 if the time is unknown
1.3.6.1.4.1.19746.1.8.1.1.1.14ReplicationSyncedTimeTCread-onlycurrent
replicationConfig
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.8.2
replicationConfigTable
OBJECT-TYPE
A table containing entries of ReplicationConfigEntry.
1.3.6.1.4.1.19746.1.8.2.1not-accessiblecurrent
replicationConfigEntry
OBJECT-TYPE
replicationConfigTable Row Description
1.3.6.1.4.1.19746.1.8.2.1.1not-accessiblecurrent
replConfigIndex
OBJECT-TYPE
ConfigIndex ID of replication source/dest pair
1.3.6.1.4.1.19746.1.8.2.1.1.1ReplicationConfigIndexTCnot-accessiblecurrent
replConfigContextId
OBJECT-TYPE
ConfigContextId of replication source/dest pair
1.3.6.1.4.1.19746.1.8.2.1.1.2ReplicationConfigContextIdTCread-onlycurrent
replConfigSource
OBJECT-TYPE
Source for replication source/dest pair connection
1.3.6.1.4.1.19746.1.8.2.1.1.3ReplicationConfigSourceTCread-onlycurrent
replConfigDest
OBJECT-TYPE
Destination for replication connection
1.3.6.1.4.1.19746.1.8.2.1.1.4ReplicationConfigDestTCread-onlycurrent
replConfigConnHost
OBJECT-TYPE
Host for a replication connection
1.3.6.1.4.1.19746.1.8.2.1.1.5ReplicationConfigConnHostTCread-onlycurrent
replConfigConnPort
OBJECT-TYPE
Replication Configuration port for the connection
1.3.6.1.4.1.19746.1.8.2.1.1.6ReplicationConfigConnPortTCread-onlycurrent
replConfigLowBWOptim
OBJECT-TYPE
Replication configuration Low BW optim
1.3.6.1.4.1.19746.1.8.2.1.1.7ReplicationConfigLowBWOptimTCread-onlycurrent
replConfigEnabled
OBJECT-TYPE
Replication config Enabled
1.3.6.1.4.1.19746.1.8.2.1.1.8ReplicationConfigEnabledTCread-onlycurrent
replConfigTenantUnit
OBJECT-TYPE
The name of the tenant-unit of a particular replication context.
1.3.6.1.4.1.19746.1.8.2.1.1.9DDMibString96TCread-onlycurrent
replicationHistory
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.8.3
replicationHistoryTable
OBJECT-TYPE
A table containing entries of replicationHistoryEntry.
1.3.6.1.4.1.19746.1.8.3.1not-accessiblecurrent
replicationHistoryEntry
OBJECT-TYPE
replicationHistoryTable Row Description
1.3.6.1.4.1.19746.1.8.3.1.1not-accessiblecurrent
replHistoryContext
OBJECT-TYPE
context ID of replication History source/dest pair
1.3.6.1.4.1.19746.1.8.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
replHistoryDate
OBJECT-TYPE
replication History Date
1.3.6.1.4.1.19746.1.8.3.1.1.2DDMibDateTCread-onlycurrent
replHistoryTime
OBJECT-TYPE
replication History Time
1.3.6.1.4.1.19746.1.8.3.1.1.3DDMibTimeStampTCread-onlycurrent
replHistoryPreCompWritten
OBJECT-TYPE
Replication History Pre comp bytes written
1.3.6.1.4.1.19746.1.8.3.1.1.4DDMibTrafficBytesTCread-onlycurrent
replHistoryPreCompRemaining
OBJECT-TYPE
Replication History Byte remaining
1.3.6.1.4.1.19746.1.8.3.1.1.5DDMibTrafficBytesTCread-onlycurrent
replHistoryPreCompressed
OBJECT-TYPE
Replication History Precompressed bytes
1.3.6.1.4.1.19746.1.8.3.1.1.6DDMibTrafficBytesTCread-onlycurrent
replHistoryPostFiltered
OBJECT-TYPE
replication history post filtered bytes
1.3.6.1.4.1.19746.1.8.3.1.1.7DDMibTrafficBytesTCread-onlycurrent
replHistoryPostLowBwOptim
OBJECT-TYPE
Replication history Post Low BW Optimum
1.3.6.1.4.1.19746.1.8.3.1.1.8DDMibTrafficBytesTCread-onlycurrent
replHistoryPostLocalComp
OBJECT-TYPE
Replication History Post Local Comp
1.3.6.1.4.1.19746.1.8.3.1.1.9DDMibTrafficBytesTCread-onlycurrent
replHistoryBytesNetwork
OBJECT-TYPE
Replication History network bytes
1.3.6.1.4.1.19746.1.8.3.1.1.10DDMibTrafficBytesTCread-onlycurrent
replHistorySyncedAsOfTime
OBJECT-TYPE
Time when the source and destination were in sync, or 0 if the time is unknown
1.3.6.1.4.1.19746.1.8.3.1.1.11DDMibInteger32TCread-onlycurrent
replicationPerformance
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.8.4
replicationPerformanceTable
OBJECT-TYPE
A table containing entries of replicationPerformanceEntry.
1.3.6.1.4.1.19746.1.8.4.1not-accessiblecurrent
replicationPerformanceEntry
OBJECT-TYPE
replicationPerformanceTable Row Description
1.3.6.1.4.1.19746.1.8.4.1.1not-accessiblecurrent
replPerformancePreCompKBPerSec
OBJECT-TYPE
Network (KB/s): The size value before compression is applied. Sometimes referred to as 'logical size.'
1.3.6.1.4.1.19746.1.8.4.1.1.1DDMibInteger32TCread-onlycurrent
replPerformanceNetworkKBPerSec
OBJECT-TYPE
Network (KB/s): The amount of compressed data transferred over the network per second.
1.3.6.1.4.1.19746.1.8.4.1.1.2DDMibInteger32TCread-onlycurrent
replPerformanceStreams
OBJECT-TYPE
An internal system resource associated with reads and writes. One replication context can use multiple streams for better performance.
1.3.6.1.4.1.19746.1.8.4.1.1.3DDMibInteger32TCread-onlycurrent
replPerformanceBusyReading
OBJECT-TYPE
The time spent reading filesystem data from the local filesystem. Typically this number is the second highest number after Network. On a deployment with high network bandwidth, Reading may be the largest column.
1.3.6.1.4.1.19746.1.8.4.1.1.4DDMibInteger32TCread-onlycurrent
replPerformanceBusyMeta
OBJECT-TYPE
The time spent on miscellaneous bookkeeping activities and replicating filesystem namespace operations. Typically this value is under 50. If this value exceeds 50 on a sustained basis, it may indicate an unusual workload (a large number of file attribute updates, for example).
1.3.6.1.4.1.19746.1.8.4.1.1.5DDMibInteger32TCread-onlycurrent
replPerformanceWaitingDest
OBJECT-TYPE
The time spent waiting due to the receiver not providing the sender enough information on what data to send. Typically this value is low. Exceptions include systems on high-speed networks where the sender is a more powerful Data Domain system than the replica, or where the replica has a higher workload than the sender because the replica is the destination for a multiple replication contexts.
1.3.6.1.4.1.19746.1.8.4.1.1.6DDMibInteger32TCread-onlycurrent
replPerformanceWaitingNetwork
OBJECT-TYPE
The time spent waiting due to the receiver not providing the sender enough information on what data to send. Typically this value is low. Exceptions include systems on high-speed networks where the sender is a more powerful Data Domain system than the replica, or where the replica has a higher workload than the sender because the replica is the destination for a multiple replication contexts.
1.3.6.1.4.1.19746.1.8.4.1.1.7DDMibInteger32TCread-onlycurrent
nfs
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.9
nfsProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.9.1
nfsStatus
OBJECT-TYPE
Status of the network file system
1.3.6.1.4.1.19746.1.9.1.1NfsStatusTCread-onlycurrent
nfsClient
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.9.2
nfsClientTable
OBJECT-TYPE
A table containing entries of NfsClientEntry.
1.3.6.1.4.1.19746.1.9.2.1not-accessiblecurrent
nfsClientEntry
OBJECT-TYPE
nfsClientTable Row Description
1.3.6.1.4.1.19746.1.9.2.1.1not-accessiblecurrent
nfsClientIndex
OBJECT-TYPE
NFS client index
1.3.6.1.4.1.19746.1.9.2.1.1.1NfsClientIndexTCnot-accessiblecurrent
nfsClientPath
OBJECT-TYPE
NFS client path
1.3.6.1.4.1.19746.1.9.2.1.1.2NfsClientPathTCread-onlycurrent
nfsClientClients
OBJECT-TYPE
List of NFS clients
1.3.6.1.4.1.19746.1.9.2.1.1.3NfsClientClientsTCread-onlycurrent
nfsClientOptions
OBJECT-TYPE
NFS client's options
1.3.6.1.4.1.19746.1.9.2.1.1.4NfsClientOptionsTCread-onlycurrent
nfsStats
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.9.3
nfsStatsTable
OBJECT-TYPE
A table containing entries of NfsStatsEntry.
1.3.6.1.4.1.19746.1.9.3.1not-accessiblecurrent
nfsStatsEntry
OBJECT-TYPE
nfsStatsTable Row Description
1.3.6.1.4.1.19746.1.9.3.1.1not-accessiblecurrent
nfsStatsIndex
OBJECT-TYPE
NFS resource index
1.3.6.1.4.1.19746.1.9.3.1.1.1NfsStatsIndexTCnot-accessiblecurrent
nfsStatsExportPoint
OBJECT-TYPE
NFS export point
1.3.6.1.4.1.19746.1.9.3.1.1.2NfsStatsExportPointTCread-onlycurrent
nfsStatsFilesystemType
OBJECT-TYPE
File system type
1.3.6.1.4.1.19746.1.9.3.1.1.3NfsStatsFilesystemTypeTCread-onlycurrent
nfsStatsCacheEntry
OBJECT-TYPE
Number of cache entries
1.3.6.1.4.1.19746.1.9.3.1.1.4NfsStatsCacheEntryTCread-onlycurrent
nfsStatsFileHandleLookup
OBJECT-TYPE
File handle lookup count
1.3.6.1.4.1.19746.1.9.3.1.1.5NfsStatsFileHandleLookupTCread-onlycurrent
nfsStatsMaxCacheSize
OBJECT-TYPE
Max cache size
1.3.6.1.4.1.19746.1.9.3.1.1.6NfsStatsMaxCacheSizeTCread-onlycurrent
nfsStatsCurrentOpenStreams
OBJECT-TYPE
Current open stream count
1.3.6.1.4.1.19746.1.9.3.1.1.7NfsStatsCurrentOpenStreamsTCread-onlycurrent
nfsActive
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.9.4
nfsActiveTable
OBJECT-TYPE
A table containing entries of Nfs Active Clients.
1.3.6.1.4.1.19746.1.9.4.1not-accessiblecurrent
nfsActiveEntry
OBJECT-TYPE
nfsActiveTable Row Description
1.3.6.1.4.1.19746.1.9.4.1.1not-accessiblecurrent
nfsActiveIndex
OBJECT-TYPE
NFS Active index
1.3.6.1.4.1.19746.1.9.4.1.1.1DDMibTableIndexTCnot-accessiblecurrent
nfsActivePath
OBJECT-TYPE
NFS Active client path
1.3.6.1.4.1.19746.1.9.4.1.1.2DDMibTableString1024TCread-onlycurrent
nfsActiveClients
OBJECT-TYPE
NFS Active Client
1.3.6.1.4.1.19746.1.9.4.1.1.3DDMibTableString1024TCread-onlycurrent
nfsPort
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.9.5
nfsPortTable
OBJECT-TYPE
A table containing entries of NfsPortEntry.
1.3.6.1.4.1.19746.1.9.5.1not-accessiblecurrent
nfsPortEntry
OBJECT-TYPE
nfsPortTable Row Description
1.3.6.1.4.1.19746.1.9.5.1.1not-accessiblecurrent
nfsPortIndex
OBJECT-TYPE
NFS Port index
1.3.6.1.4.1.19746.1.9.5.1.1.1DDMibTableIndexTCnot-accessiblecurrent
nfsPortService
OBJECT-TYPE
NFS Port Service Name
1.3.6.1.4.1.19746.1.9.5.1.1.2DDMibTableString32TCread-onlycurrent
nfsPortPort
OBJECT-TYPE
NFS Service Port
1.3.6.1.4.1.19746.1.9.5.1.1.3DDMibTableString32TCread-onlycurrent
cifs
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.10
cifsProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.10.1
cifsStatus
OBJECT-TYPE
CIFS status
1.3.6.1.4.1.19746.1.10.1.1CifsStatusTCread-onlycurrent
cifsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.10.2
cifsConfigMode
OBJECT-TYPE
CIFS configuration mode
1.3.6.1.4.1.19746.1.10.2.1CifsConfigModeTCread-onlycurrent
cifsConfigWINSServer
OBJECT-TYPE
CIFS WINS server
1.3.6.1.4.1.19746.1.10.2.2CifsConfigWINSServerTCread-onlycurrent
cifsConfigNetBIOSHostname
OBJECT-TYPE
CIFS Net BIOS hostname
1.3.6.1.4.1.19746.1.10.2.3CifsConfigNetBIOSHostnameTCread-onlycurrent
cifsConfigDomainController
OBJECT-TYPE
CIFS domain controller
1.3.6.1.4.1.19746.1.10.2.4CifsConfigDomainControllerTCread-onlycurrent
cifsConfigDNS
OBJECT-TYPE
CIFS DNS server
1.3.6.1.4.1.19746.1.10.2.5CifsConfigDNSTCread-onlycurrent
cifsConfigGroupName
OBJECT-TYPE
CIFS configuration group name
1.3.6.1.4.1.19746.1.10.2.6CifsConfigGroupNameTCread-onlycurrent
cifsConfigMaxConnection
OBJECT-TYPE
CIFS configuration maximum connection
1.3.6.1.4.1.19746.1.10.2.7CifsConfigMaxConnectionTCread-onlycurrent
cifsConfigMaxOpenFilesPerConnection
OBJECT-TYPE
CIFS configuration maximum open files per connection
1.3.6.1.4.1.19746.1.10.2.8CifsConfigMaxOpenFilesPerConnectionTCread-onlydeprecated
cifsConfigMaxOpenFiles
OBJECT-TYPE
CIFS configuration maximum open files
1.3.6.1.4.1.19746.1.10.2.9Counter32read-onlycurrent
cifsShare
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.10.3
cifsShareTable
OBJECT-TYPE
A table containing entries of CifsShareEntry.
1.3.6.1.4.1.19746.1.10.3.1not-accessiblecurrent
cifsShareEntry
OBJECT-TYPE
cifsShareTable Row Description
1.3.6.1.4.1.19746.1.10.3.1.1not-accessiblecurrent
cifsShareIndex
OBJECT-TYPE
CIFS share index
1.3.6.1.4.1.19746.1.10.3.1.1.1CifsShareIndexTCnot-accessiblecurrent
cifsShareName
OBJECT-TYPE
CIFS share name
1.3.6.1.4.1.19746.1.10.3.1.1.2CifsShareNameTCread-onlycurrent
cifsSharePath
OBJECT-TYPE
CIFS share path
1.3.6.1.4.1.19746.1.10.3.1.1.3CifsSharePathTCread-onlycurrent
cifsShareClients
OBJECT-TYPE
CIFS share clients
1.3.6.1.4.1.19746.1.10.3.1.1.4CifsShareClientsTCread-onlycurrent
cifsShareUser
OBJECT-TYPE
CIFS share user
1.3.6.1.4.1.19746.1.10.3.1.1.5CifsShareUserTCread-onlycurrent
cifsShareComment
OBJECT-TYPE
CIFS share comment
1.3.6.1.4.1.19746.1.10.3.1.1.6CifsShareCommentTCread-onlycurrent
cifsShareBrowsing
OBJECT-TYPE
CIFS share browsing
1.3.6.1.4.1.19746.1.10.3.1.1.7CifsShareBrowsingTCread-onlycurrent
cifsShareWriteable
OBJECT-TYPE
CIFS share writeable
1.3.6.1.4.1.19746.1.10.3.1.1.8CifsShareWriteableTCread-onlycurrent
cifsShareMaxConnection
OBJECT-TYPE
CIFS share maximum connection
1.3.6.1.4.1.19746.1.10.3.1.1.9CifsShareMaxConnectionTCread-onlycurrent
cifsOptions
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.10.5
cifsOptionsTable
OBJECT-TYPE
A table containing entries of CifsOptionsEntry.
1.3.6.1.4.1.19746.1.10.5.1not-accessiblecurrent
cifsOptionsEntry
OBJECT-TYPE
cifsOptionsTable Row Description
1.3.6.1.4.1.19746.1.10.5.1.1not-accessiblecurrent
cifsOptionsIndex
OBJECT-TYPE
CIFS Options index
1.3.6.1.4.1.19746.1.10.5.1.1.1CifsOptionsIndexTCnot-accessiblecurrent
cifsOptionsName
OBJECT-TYPE
CIFS Options name
1.3.6.1.4.1.19746.1.10.5.1.1.2CifsOptionsNameTCread-onlycurrent
cifsOptionsValue
OBJECT-TYPE
CIFS Options Value
1.3.6.1.4.1.19746.1.10.5.1.1.3CifsOptionsValueTCread-onlycurrent
vtl
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11
vtlProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.1
vtlAdminState
OBJECT-TYPE
State of VTL administration
1.3.6.1.4.1.19746.1.11.1.1VtlAdminStateTCread-onlycurrent
vtlProcessState
OBJECT-TYPE
State of VTL process
1.3.6.1.4.1.19746.1.11.1.2VtlProcessStateTCread-onlycurrent
vtlConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2
vtlLibrary
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.1
vtlLibraryTable
OBJECT-TYPE
A table containing entries of VtlLibraryEntry.
1.3.6.1.4.1.19746.1.11.2.1.1not-accessiblecurrent
vtlLibraryEntry
OBJECT-TYPE
vtlLibraryTable Row Description
1.3.6.1.4.1.19746.1.11.2.1.1.1not-accessiblecurrent
vtlLibraryIndex
OBJECT-TYPE
VTL Library index
1.3.6.1.4.1.19746.1.11.2.1.1.1.1VtlLibraryIndexTCnot-accessiblecurrent
vtlLibraryName
OBJECT-TYPE
VTL library name
1.3.6.1.4.1.19746.1.11.2.1.1.1.2VtlLibraryNameTCread-onlycurrent
vtlLibraryVendor
OBJECT-TYPE
VTL library vendor
1.3.6.1.4.1.19746.1.11.2.1.1.1.3VtlLibraryVendorTCread-onlycurrent
vtlLibraryModel
OBJECT-TYPE
VTL library model
1.3.6.1.4.1.19746.1.11.2.1.1.1.4VtlLibraryModelTCread-onlycurrent
vtlLibraryRevision
OBJECT-TYPE
VTL library revision
1.3.6.1.4.1.19746.1.11.2.1.1.1.5VtlLibraryRevisionTCread-onlycurrent
vtlLibrarySerial
OBJECT-TYPE
VTL library serial
1.3.6.1.4.1.19746.1.11.2.1.1.1.6VtlLibrarySerialTCread-onlycurrent
vtlLibraryTotalDrives
OBJECT-TYPE
VTL library total drives
1.3.6.1.4.1.19746.1.11.2.1.1.1.7VtlLibraryTotalDrivesTCread-onlycurrent
vtlLibraryTotalSlots
OBJECT-TYPE
VTL library total slots
1.3.6.1.4.1.19746.1.11.2.1.1.1.8VtlLibraryTotalSlotsTCread-onlycurrent
vtlLibraryTotalCaps
OBJECT-TYPE
VTL library total caps
1.3.6.1.4.1.19746.1.11.2.1.1.1.9VtlLibraryTotalCapsTCread-onlycurrent
vtlLibraryStatus
OBJECT-TYPE
VTL library status
1.3.6.1.4.1.19746.1.11.2.1.1.1.10VtlLibraryStatusTCread-onlycurrent
vtlDrive
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.2
vtlDriveTable
OBJECT-TYPE
A table containing entries of VtlDriveEntry.
1.3.6.1.4.1.19746.1.11.2.2.1not-accessiblecurrent
vtlDriveEntry
OBJECT-TYPE
vtlDriveTable Row Description
1.3.6.1.4.1.19746.1.11.2.2.1.1not-accessiblecurrent
vtlDriveIndex
OBJECT-TYPE
VTL drive index
1.3.6.1.4.1.19746.1.11.2.2.1.1.1VtlDriveIndexTCnot-accessiblecurrent
vtlDriveName
OBJECT-TYPE
VTL drive name
1.3.6.1.4.1.19746.1.11.2.2.1.1.2VtlDriveNameTCread-onlycurrent
vtlDriveVendor
OBJECT-TYPE
VTL drive vendor
1.3.6.1.4.1.19746.1.11.2.2.1.1.3VtlDriveVendorTCread-onlycurrent
vtlDriveModel
OBJECT-TYPE
VTL drive model
1.3.6.1.4.1.19746.1.11.2.2.1.1.4VtlDriveModelTCread-onlycurrent
vtlDriveRevision
OBJECT-TYPE
VTL drive revision
1.3.6.1.4.1.19746.1.11.2.2.1.1.5VtlDriveRevisionTCread-onlycurrent
vtlDriveSerial
OBJECT-TYPE
VTL drive serial
1.3.6.1.4.1.19746.1.11.2.2.1.1.6VtlDriveSerialTCread-onlycurrent
vtlDriveLibraryName
OBJECT-TYPE
VTL drive library name
1.3.6.1.4.1.19746.1.11.2.2.1.1.7VtlLibraryNameTCread-onlycurrent
vtlDriveStatus
OBJECT-TYPE
VTL drive status
1.3.6.1.4.1.19746.1.11.2.2.1.1.8VtlDriveStatusTCread-onlycurrent
vtlDriveTapeVolume
OBJECT-TYPE
VTL drive tape volume
1.3.6.1.4.1.19746.1.11.2.2.1.1.9VtlDriveTapeVolumeTCread-onlycurrent
vtlPort
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.3
vtlPortTable
OBJECT-TYPE
A table containing entries of VtlPortEntry.
1.3.6.1.4.1.19746.1.11.2.3.1not-accessiblecurrent
vtlPortEntry
OBJECT-TYPE
vtlPortTable Row Description
1.3.6.1.4.1.19746.1.11.2.3.1.1not-accessiblecurrent
vtlPortIndex
OBJECT-TYPE
VTL Port index
1.3.6.1.4.1.19746.1.11.2.3.1.1.1VtlPortIndexTCnot-accessiblecurrent
vtlPortName
OBJECT-TYPE
VTL Port name
1.3.6.1.4.1.19746.1.11.2.3.1.1.2VtlPortNameTCread-onlycurrent
vtlPortID
OBJECT-TYPE
VTL Port ID
1.3.6.1.4.1.19746.1.11.2.3.1.1.3VtlPortIDTCread-onlycurrent
vtlPortModel
OBJECT-TYPE
VTL Port model
1.3.6.1.4.1.19746.1.11.2.3.1.1.4VtlPortModelTCread-onlycurrent
vtlPortFirmware
OBJECT-TYPE
VTL Port Firmware Version
1.3.6.1.4.1.19746.1.11.2.3.1.1.5VtlPortFirmwareTCread-onlycurrent
vtlPortWWNN
OBJECT-TYPE
VTL Port WWNN address
1.3.6.1.4.1.19746.1.11.2.3.1.1.6VtlPortWWNNTCread-onlycurrent
vtlPortWWPN
OBJECT-TYPE
VTL Port WWPN Address
1.3.6.1.4.1.19746.1.11.2.3.1.1.7VtlPortWWPNTCread-onlycurrent
vtlPortConnectionType
OBJECT-TYPE
VTL Port Connection Type
1.3.6.1.4.1.19746.1.11.2.3.1.1.8VtlPortConnectionTypeTCread-onlycurrent
vtlPortSpeed
OBJECT-TYPE
VTL Port Speed in Gibs
1.3.6.1.4.1.19746.1.11.2.3.1.1.9VtlPortSpeedTCread-onlycurrent
vtlPortEnabled
OBJECT-TYPE
VTL Port Enabled
1.3.6.1.4.1.19746.1.11.2.3.1.1.10VtlPortEnabledTCread-onlycurrent
vtlPortStatus
OBJECT-TYPE
VTL Port Status
1.3.6.1.4.1.19746.1.11.2.3.1.1.11VtlPortStatusTCread-onlycurrent
vtlPortTrapIndex
OBJECT-TYPE
VTL Port index
1.3.6.1.4.1.19746.1.11.2.3.1.1.12VtlPortIndexTCread-onlycurrent
vtlTape
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.4
vtlTapeTable
OBJECT-TYPE
A table containing entries of VtlTapeEntry.
1.3.6.1.4.1.19746.1.11.2.4.1not-accessiblecurrent
vtlTapeEntry
OBJECT-TYPE
vtlTapeTable Row Description
1.3.6.1.4.1.19746.1.11.2.4.1.1not-accessiblecurrent
vtlTapeIndex
OBJECT-TYPE
VTL Tape index
1.3.6.1.4.1.19746.1.11.2.4.1.1.1VtlTapeIndexTCnot-accessiblecurrent
vtlTapeBarCode
OBJECT-TYPE
VTL Tape BarCode
1.3.6.1.4.1.19746.1.11.2.4.1.1.2VtlTapeBarCodeTCread-onlycurrent
vtlTapePool
OBJECT-TYPE
VTL Tape Pool
1.3.6.1.4.1.19746.1.11.2.4.1.1.3VtlTapePoolTCread-onlycurrent
vtlTapeLocation
OBJECT-TYPE
VTL Tape Location
1.3.6.1.4.1.19746.1.11.2.4.1.1.4VtlTapeLocationTCread-onlycurrent
vtlTapeState
OBJECT-TYPE
VTL Tape State
1.3.6.1.4.1.19746.1.11.2.4.1.1.5VtlTapeStateTCread-onlycurrent
vtlTapeSize
OBJECT-TYPE
VTL Tape Size
1.3.6.1.4.1.19746.1.11.2.4.1.1.6VtlTapeSizeTCread-onlycurrent
vtlTapeUsed
OBJECT-TYPE
VTL Tape Used
1.3.6.1.4.1.19746.1.11.2.4.1.1.7VtlTapeUsedTCread-onlycurrent
vtlTapeComp
OBJECT-TYPE
VTL Tape Compression
1.3.6.1.4.1.19746.1.11.2.4.1.1.8VtlTapeCompTCread-onlycurrent
vtlTapeModTime
OBJECT-TYPE
VTL Tape status
1.3.6.1.4.1.19746.1.11.2.4.1.1.9VtlTapeModTimeTCread-onlycurrent
vtlPool
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.6
vtlPoolTable
OBJECT-TYPE
A table containing entries of VtlPoolEntry.
1.3.6.1.4.1.19746.1.11.2.6.1not-accessiblecurrent
vtlPoolEntry
OBJECT-TYPE
vtlPoolTable Row Description
1.3.6.1.4.1.19746.1.11.2.6.1.1not-accessiblecurrent
vtlPoolIndex
OBJECT-TYPE
VTL Pool index
1.3.6.1.4.1.19746.1.11.2.6.1.1.1DDMibTableIndexTCnot-accessiblecurrent
vtlPoolPool
OBJECT-TYPE
VTL Pool Pool
1.3.6.1.4.1.19746.1.11.2.6.1.1.2DDMibTableString64TCread-onlycurrent
vtlPoolStatus
OBJECT-TYPE
VTL Pool Status
1.3.6.1.4.1.19746.1.11.2.6.1.1.3DDMibTableString64TCread-onlycurrent
vtlPoolTapes
OBJECT-TYPE
VTL Pool Tapes
1.3.6.1.4.1.19746.1.11.2.6.1.1.4DDMibTableString64TCread-onlycurrent
vtlPoolSize
OBJECT-TYPE
VTL Pool Size
1.3.6.1.4.1.19746.1.11.2.6.1.1.5DDMibTableString64TCread-onlycurrent
vtlPoolUsed
OBJECT-TYPE
VTL Pool Used
1.3.6.1.4.1.19746.1.11.2.6.1.1.6DDMibTableString64TCread-onlycurrent
vtlPoolComp
OBJECT-TYPE
VTL Pool Compression
1.3.6.1.4.1.19746.1.11.2.6.1.1.7DDMibTableString64TCread-onlycurrent
vtlGroups
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.7
vtlGroupTable
OBJECT-TYPE
A table containing entries of VtlGroupEntry.
1.3.6.1.4.1.19746.1.11.2.7.1not-accessiblecurrent
vtlGroupEntry
OBJECT-TYPE
vtlGroupTable Row Description
1.3.6.1.4.1.19746.1.11.2.7.1.1not-accessiblecurrent
vtlGroupIndex
OBJECT-TYPE
VTL Group index
1.3.6.1.4.1.19746.1.11.2.7.1.1.1DDMibTableIndexTCnot-accessiblecurrent
vtlGroupName
OBJECT-TYPE
VTL Group Name
1.3.6.1.4.1.19746.1.11.2.7.1.1.2DDMibTableString32TCread-onlycurrent
vtlGroupInitiaterCount
OBJECT-TYPE
VTL Group Initiater Count
1.3.6.1.4.1.19746.1.11.2.7.1.1.3DDMibInteger32TCread-onlycurrent
vtlGroupDeviceCount
OBJECT-TYPE
VTL Group Device Count
1.3.6.1.4.1.19746.1.11.2.7.1.1.4DDMibInteger32TCread-onlycurrent
vtlGroupDeviceTable
OBJECT-TYPE
This table contains information about the devices in VTL groups. It provides information such as the Device Name, the Device LUN, the Primary Ports, Secondary Ports, In-Use Ports, and Group Name. It is comprised of entries of VtlGroupDeviceEntry.
1.3.6.1.4.1.19746.1.11.2.7.2not-accessiblecurrent
vtlGroupDeviceEntry
OBJECT-TYPE
Information about the devices in a VTL group.
1.3.6.1.4.1.19746.1.11.2.7.2.1not-accessiblecurrent
vtlGroupDeviceIndex
OBJECT-TYPE
The index of a VTL Device.
1.3.6.1.4.1.19746.1.11.2.7.2.1.2DDMibTableIndexTCnot-accessiblecurrent
vtlGroupDeviceGroupName
OBJECT-TYPE
The name of a VTL Group.
1.3.6.1.4.1.19746.1.11.2.7.2.1.3DDMibTableString256TCread-onlycurrent
vtlGroupDeviceDeviceName
OBJECT-TYPE
The name of a VTL Device.
1.3.6.1.4.1.19746.1.11.2.7.2.1.4DDMibTableString256TCread-onlycurrent
vtlGroupDeviceLun
OBJECT-TYPE
The LUN (Logical Unit Number) of a VTL Device.
1.3.6.1.4.1.19746.1.11.2.7.2.1.5DDMibInteger32TCread-onlycurrent
vtlGroupDevicePrimaryPorts
OBJECT-TYPE
The Primary Ports of a VTL Device. This entry specifies a set of ports that the device will be visible on. If 'all' is provided the device is visible on all ports. If 'none' is provided the device is visible on none of the ports.
1.3.6.1.4.1.19746.1.11.2.7.2.1.6DDMibTableString64TCread-onlycurrent
vtlGroupDeviceSecondaryPorts
OBJECT-TYPE
The Secondary Ports of a VTL Device. This entry specifies a second set of ports that the device will be visible on. The administrator can switch the ports in use in a group to the primary or secondary port list.
1.3.6.1.4.1.19746.1.11.2.7.2.1.7DDMibTableString64TCread-onlycurrent
vtlGroupDeviceInUsePorts
OBJECT-TYPE
The In-Use Ports of a VTL Device. The port list that the device is visible on is the in-use port list, which can be the primary or secondary port list.
1.3.6.1.4.1.19746.1.11.2.7.2.1.8DDMibTableString64TCread-onlycurrent
vtlInitiator
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.2.8
vtlInitiatorTable
OBJECT-TYPE
A table containing entries of VtlInitiatorEntry.
1.3.6.1.4.1.19746.1.11.2.8.1not-accessiblecurrent
vtlInitiatorEntry
OBJECT-TYPE
vtlInitiatorTable Row Description
1.3.6.1.4.1.19746.1.11.2.8.1.1not-accessiblecurrent
vtlInitiatorIndex
OBJECT-TYPE
VTL Initiator index
1.3.6.1.4.1.19746.1.11.2.8.1.1.1DDMibTableIndexTCnot-accessiblecurrent
vtlInitiatorName
OBJECT-TYPE
VTL Initiator Name
1.3.6.1.4.1.19746.1.11.2.8.1.1.2DDMibTableString32TCread-onlycurrent
vtlInitiatorStatus
OBJECT-TYPE
VTL Initiator Status
1.3.6.1.4.1.19746.1.11.2.8.1.1.3DDMibTableString32TCread-onlycurrent
vtlInitiatorGroup
OBJECT-TYPE
VTL Initiator Group
1.3.6.1.4.1.19746.1.11.2.8.1.1.4DDMibTableString32TCread-onlycurrent
vtlInitiatorWWNN
OBJECT-TYPE
VTL Initiator WWNN
1.3.6.1.4.1.19746.1.11.2.8.1.1.5DDMibTableString64TCread-onlycurrent
vtlInitiatorWWPN
OBJECT-TYPE
VTL Initiator WWPN
1.3.6.1.4.1.19746.1.11.2.8.1.1.6DDMibTableString64TCread-onlycurrent
vtlInitiatorPort
OBJECT-TYPE
VTL Initiator Port
1.3.6.1.4.1.19746.1.11.2.8.1.1.7DDMibTableString32TCread-onlycurrent
vtlStats
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.11.3
vtlStatsTable
OBJECT-TYPE
This table contains detailed statistical information about the individual VTL Ports on a Data Domain System. It includes the count of Control Commands, Write Commands, and Read Commands. The amount of data In, and Out. The count of Link Failures, LIP count, Sync Losses, Signal Losses, Prim Seq Proto Errors, Invalid Tx Words, and Invalid CRCs. It is comprised of entries of VtlStatsEntry.
1.3.6.1.4.1.19746.1.11.3.1not-accessiblecurrent
vtlStatsEntry
OBJECT-TYPE
vtlStatsTable Row Description
1.3.6.1.4.1.19746.1.11.3.1.1not-accessiblecurrent
vtlStatsIndex
OBJECT-TYPE
VTL Stats Index. The index of the VTL Per-Port Statistical entry.
1.3.6.1.4.1.19746.1.11.3.1.1.1VtlStatsIndexTCnot-accessiblecurrent
vtlStatsPort
OBJECT-TYPE
VTL Stats Port. The physical VTL port number.
1.3.6.1.4.1.19746.1.11.3.1.1.2VtlStatsPortTCread-onlycurrent
vtlStatsConrolCommands
OBJECT-TYPE
VTL Stats Control Commands. The number of non read/write commands.
1.3.6.1.4.1.19746.1.11.3.1.1.3VtlStatsConrolCommandsTCread-onlycurrent
vtlStatsWriteCommands
OBJECT-TYPE
VTL Stats Write Commands. The number of WRITE commands.
1.3.6.1.4.1.19746.1.11.3.1.1.4VtlStatsWriteCommandsTCread-onlycurrent
vtlStatsReadCommands
OBJECT-TYPE
VTL Stats Read Commands. The number of READ commands.
1.3.6.1.4.1.19746.1.11.3.1.1.5VtlStatsReadCommandsTCread-onlycurrent
vtlStatsIn
OBJECT-TYPE
VTL Stats In. The number of megabytes written to the specific port.
1.3.6.1.4.1.19746.1.11.3.1.1.6VtlStatsInTCread-onlycurrent
vtlStatsOut
OBJECT-TYPE
VTL Stats Out. The number of megabytes read from the specific port.
1.3.6.1.4.1.19746.1.11.3.1.1.7VtlStatsOutTCread-onlycurrent
vtlStatsLinkFailures
OBJECT-TYPE
VTL Stats Link Failures. The count of Link Failures.
1.3.6.1.4.1.19746.1.11.3.1.1.8VtlStatsLinkFailuresTCread-onlycurrent
vtlStatsLIPCount
OBJECT-TYPE
VTL Stats LIP Count. The number of LIPs.
1.3.6.1.4.1.19746.1.11.3.1.1.9VtlStatsLIPCountTCread-onlycurrent
vtlStatsSyncLosses
OBJECT-TYPE
VTL Stats Sync Losses. The number of times sync loss was detected.
1.3.6.1.4.1.19746.1.11.3.1.1.10VtlStatsSyncLossesTCread-onlycurrent
vtlStatsSignalLosses
OBJECT-TYPE
VTL Stats Signal Losses. The number of times loss of signal was detected.
1.3.6.1.4.1.19746.1.11.3.1.1.11VtlStatsSignalLossesTCread-onlycurrent
vtlStatsPrimSeqProtoErrors
OBJECT-TYPE
VTL Stats Prim Seq Proto Errors. The count of errors in the Primitive Sequence Protocol.
1.3.6.1.4.1.19746.1.11.3.1.1.12VtlStatsPrimSeqProtoErrorsTCread-onlycurrent
vtlStatsInvalidTxWords
OBJECT-TYPE
VTL Stats Invalid Tx Words. The number of invalid TX words.
1.3.6.1.4.1.19746.1.11.3.1.1.13VtlStatsInvalidTxWordsTCread-onlycurrent
vtlStatsInvalidCRCs
OBJECT-TYPE
VTL Stats Invalid CRCs. The number of frames received with bad CRC.
1.3.6.1.4.1.19746.1.11.3.1.1.14VtlStatsInvalidCRCsTCread-onlycurrent
ddboost
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12
ddboostProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.1
ddboostStatus
OBJECT-TYPE
The status of the DDBoost interface group on a DD system.
1.3.6.1.4.1.19746.1.12.1.1DDboostStatusTCread-onlycurrent
ddboostUser
OBJECT-TYPE
DDBoost User.
1.3.6.1.4.1.19746.1.12.1.2DDboostUserTCread-onlydeprecated
ddboostIfGroupStatus
OBJECT-TYPE
DDBoost IfGroup Status.
1.3.6.1.4.1.19746.1.12.1.3DDMibStatusTCread-onlydeprecated
ddboostUserTable
OBJECT-TYPE
This table contains information about DDBoost users.
1.3.6.1.4.1.19746.1.12.1.4not-accessiblecurrent
ddboostUserEntry
OBJECT-TYPE
ddboostUserTable Row Entry.
1.3.6.1.4.1.19746.1.12.1.4.1not-accessiblecurrent
ddboostUserIdx
OBJECT-TYPE
DDBoost users table index.
1.3.6.1.4.1.19746.1.12.1.4.1.1DDboostStatsIndexTCnot-accessiblecurrent
ddboostUserName
OBJECT-TYPE
The name of a Ddboost user.
1.3.6.1.4.1.19746.1.12.1.4.1.2DDMibTableString256TCread-onlycurrent
ddboostUserDefaultTenantUnit
OBJECT-TYPE
The default tenant unit that is associated with a specific DDBoost user.
1.3.6.1.4.1.19746.1.12.1.4.1.3DDMibTableString256TCread-onlycurrent
ddboostIfGroupTable
OBJECT-TYPE
DDBoost IfGroup table containing interface group information.
1.3.6.1.4.1.19746.1.12.1.5not-accessiblecurrent
ddboostIfGroupEntry
OBJECT-TYPE
ddboostIfGroupTable Row Entry.
1.3.6.1.4.1.19746.1.12.1.5.1not-accessiblecurrent
ddboostIfGroupIdx
OBJECT-TYPE
DDBoost IfGroup table index.
1.3.6.1.4.1.19746.1.12.1.5.1.1DDboostStatsIndexTCnot-accessiblecurrent
ddboostIfGroupName
OBJECT-TYPE
The name of DDBoost IfGroup.
1.3.6.1.4.1.19746.1.12.1.5.1.2DDMibTableString256TCread-onlycurrent
ddboostIfGroupCurrentStatus
OBJECT-TYPE
The status of a DDBoost IfGroup. Possible values are: 'enabled' or 'disabled'.
1.3.6.1.4.1.19746.1.12.1.5.1.3DDMibStatusTCread-onlycurrent
ddboostStats
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.2
ddboostStatsTable
OBJECT-TYPE
DDBOOST stats table containing byte statistics information for DDBOOST
1.3.6.1.4.1.19746.1.12.2.1not-accessiblecurrent
ddboostStatsEntry
OBJECT-TYPE
ddboostStatsTable Row Entry
1.3.6.1.4.1.19746.1.12.2.1.1not-accessiblecurrent
ddboostStatsIndex
OBJECT-TYPE
ddboost Stats Table index
1.3.6.1.4.1.19746.1.12.2.1.1.1DDboostStatsIndexTCnot-accessiblecurrent
ddboostPreCompKBytesPerSecond
OBJECT-TYPE
Number of pre-compressed (logical) bytes received per second
1.3.6.1.4.1.19746.1.12.2.1.1.2KBytesPerSecondread-onlycurrent
ddboostPostCompKBytesPerSecond
OBJECT-TYPE
number of pddboost local compression bytes received per second
1.3.6.1.4.1.19746.1.12.2.1.1.3KBytesPerSecondread-onlycurrent
ddboostNetworkKBytesPerSecond
OBJECT-TYPE
Number of physical network bytes received per second
1.3.6.1.4.1.19746.1.12.2.1.1.4KBytesPerSecondread-onlycurrent
ddboostReadKBytesPerSecond
OBJECT-TYPE
Number of bytes read per second
1.3.6.1.4.1.19746.1.12.2.1.1.5KBytesPerSecondread-onlycurrent
ddboostStatsBackupConn
OBJECT-TYPE
Number of backup connections
1.3.6.1.4.1.19746.1.12.2.1.1.6Counter64read-onlycurrent
ddboostStatsRestoreConn
OBJECT-TYPE
Number of restore connections
1.3.6.1.4.1.19746.1.12.2.1.1.7Counter64read-onlycurrent
ddboostStatsImageCreatesCount
OBJECT-TYPE
Number of image creates
1.3.6.1.4.1.19746.1.12.2.1.1.8Counter64read-onlycurrent
ddboostStatsImageCreatesErrors
OBJECT-TYPE
Number of image creates errors
1.3.6.1.4.1.19746.1.12.2.1.1.9Counter64read-onlycurrent
ddboostStatsImageDeletesCount
OBJECT-TYPE
Number of image deletes
1.3.6.1.4.1.19746.1.12.2.1.1.10Counter64read-onlycurrent
ddboostStatsImageDeletesErrors
OBJECT-TYPE
Number of image deletes errors
1.3.6.1.4.1.19746.1.12.2.1.1.11Counter64read-onlycurrent
ddboostStatsPrecompBytesReceived
OBJECT-TYPE
Number of pre-compressed (logical) bytes received
1.3.6.1.4.1.19746.1.12.2.1.1.12DDMibTrafficBytesTCread-onlycurrent
ddboostStatsBytesAfterFiltering
OBJECT-TYPE
Number of bytes after filtering
1.3.6.1.4.1.19746.1.12.2.1.1.13DDMibTrafficBytesTCread-onlycurrent
ddboostStatsBytesAfterLc
OBJECT-TYPE
Number of bytes after local compression
1.3.6.1.4.1.19746.1.12.2.1.1.14DDMibTrafficBytesTCread-onlycurrent
ddboostStatsNetworkBytesReceived
OBJECT-TYPE
Number of network bytes received
1.3.6.1.4.1.19746.1.12.2.1.1.15DDMibTrafficBytesTCread-onlycurrent
ddboostStatsCompressionRatio
OBJECT-TYPE
Compression ratio
1.3.6.1.4.1.19746.1.12.2.1.1.16DDMibTableString32TCread-onlycurrent
ddboostStatsTotalBytesReadCount
OBJECT-TYPE
Total bytes read count
1.3.6.1.4.1.19746.1.12.2.1.1.17DDMibTrafficBytesTCread-onlycurrent
ddboostStatsTotalBytesReadErrors
OBJECT-TYPE
Total bytes read errors
1.3.6.1.4.1.19746.1.12.2.1.1.18DDMibTrafficBytesTCread-onlycurrent
ddboostConnections
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.3
ddboostConnectionsTable
OBJECT-TYPE
DDBOOST connections table information for DDBOOST Client Connections
1.3.6.1.4.1.19746.1.12.3.1not-accessiblecurrent
ddboostConnectionsEntry
OBJECT-TYPE
ddboostConnectionsTable Row Entry
1.3.6.1.4.1.19746.1.12.3.1.1not-accessiblecurrent
ddboostConnectionsIndex
OBJECT-TYPE
ddboost connections Table index
1.3.6.1.4.1.19746.1.12.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostInterface
OBJECT-TYPE
DDboost Interface Name
1.3.6.1.4.1.19746.1.12.3.1.1.2DDMibTableString64TCread-onlycurrent
ddboostifGroupMember
OBJECT-TYPE
If Member of ifGroup
1.3.6.1.4.1.19746.1.12.3.1.1.3DDMibTableEnabledTCread-onlycurrent
ddboostBackupConnections
OBJECT-TYPE
DDboost backup connections
1.3.6.1.4.1.19746.1.12.3.1.1.4DDMibInteger32TCread-onlycurrent
ddboostRestoreConnections
OBJECT-TYPE
DDboost Restore connections
1.3.6.1.4.1.19746.1.12.3.1.1.5DDMibInteger32TCread-onlycurrent
ddboostControlConnections
OBJECT-TYPE
DDboost control connections
1.3.6.1.4.1.19746.1.12.3.1.1.6DDMibInteger32TCread-onlycurrent
ddboostTotalConnections
OBJECT-TYPE
DDboost Total connections
1.3.6.1.4.1.19746.1.12.3.1.1.7DDMibInteger32TCread-onlycurrent
ddboostStorageUnit
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.4
ddboostStorageUnitTable
OBJECT-TYPE
DDBOOST StorageUnit table information for DDBOOST Storage Units
1.3.6.1.4.1.19746.1.12.4.1not-accessiblecurrent
ddboostStorageUnitEntry
OBJECT-TYPE
ddboostStorageUnitTable Row Entry
1.3.6.1.4.1.19746.1.12.4.1.1not-accessiblecurrent
ddboostStorageUnitIndex
OBJECT-TYPE
ddboost StorageUnit Table index
1.3.6.1.4.1.19746.1.12.4.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostStorageUnitName
OBJECT-TYPE
DDboost Storage Unit Name
1.3.6.1.4.1.19746.1.12.4.1.1.2DDMibTableString64TCread-onlycurrent
ddboostStorageUnitBytes
OBJECT-TYPE
DDboost Storage Unit Original MiB.
1.3.6.1.4.1.19746.1.12.4.1.1.3DDMibInteger32TCread-onlycurrent
ddboostStorageUnitGlobalComp
OBJECT-TYPE
DDboost Storage Unit Globally Compressed MiB.
1.3.6.1.4.1.19746.1.12.4.1.1.4DDMibInteger32TCread-onlycurrent
ddboostStorageUnitLocalComp
OBJECT-TYPE
DDboost Storage Unit Locally Compressed MiB.
1.3.6.1.4.1.19746.1.12.4.1.1.5DDMibInteger32TCread-onlycurrent
ddboostStorageUnitMetaData
OBJECT-TYPE
DDboost Storage Unit Meta Data MiB.
1.3.6.1.4.1.19746.1.12.4.1.1.6DDMibInteger32TCread-onlycurrent
ddboostStorageUnitStatus
OBJECT-TYPE
DDboost Storage Unit Status.
1.3.6.1.4.1.19746.1.12.4.1.1.7DDMibTableString64TCread-onlycurrent
ddboostStorageUnitPreComp
OBJECT-TYPE
DDboost Storage Unit Pre-Compression Rate.
1.3.6.1.4.1.19746.1.12.4.1.1.8DDMibTableString64TCread-onlycurrent
ddboostStorageUnitUser
OBJECT-TYPE
The User of the DDboost Storage Unit.
1.3.6.1.4.1.19746.1.12.4.1.1.9DDMibTableString64TCread-onlycurrent
ddboostStorageUnitReportPhysicalSize
OBJECT-TYPE
DDboost Storage Unit Report Physical Size.
1.3.6.1.4.1.19746.1.12.4.1.1.10DDMibInteger32TCread-onlycurrent
ddboostFileReplicationStats
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.5
ddboostFileReplicationStatsTable
OBJECT-TYPE
DDBOOST FileReplicationStats table contains information for File Replication Stats
1.3.6.1.4.1.19746.1.12.5.1not-accessiblecurrent
ddboostFileReplicationStatsEntry
OBJECT-TYPE
ddboostFileReplicationStatsTable Row Entry
1.3.6.1.4.1.19746.1.12.5.1.1not-accessiblecurrent
ddboostFileReplStatsIndex
OBJECT-TYPE
ddboost FileReplicationStats Table index
1.3.6.1.4.1.19746.1.12.5.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostFileReplStatsDirection
OBJECT-TYPE
DDboost File Replication Direction
1.3.6.1.4.1.19746.1.12.5.1.1.2DDMibTableString32TCread-onlycurrent
ddboostFileReplStatsNetworkSent
OBJECT-TYPE
DDBoost File Replication Network Bytes Sent
1.3.6.1.4.1.19746.1.12.5.1.1.3DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplStatsPreCompSent
OBJECT-TYPE
DDBoost File Replication Pre Compressed bytes sent
1.3.6.1.4.1.19746.1.12.5.1.1.4DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplStatsFiltered
OBJECT-TYPE
DDBoost File Replication Bytes after Filtering
1.3.6.1.4.1.19746.1.12.5.1.1.5DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplStatsLowBWOpt
OBJECT-TYPE
DDBoost File Replication Bytes after Low Bandwidth optimization
1.3.6.1.4.1.19746.1.12.5.1.1.6DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplStatsLocalComp
OBJECT-TYPE
DDBoost File Replication Bytes after local compression
1.3.6.1.4.1.19746.1.12.5.1.1.7DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplStatsCompRatio
OBJECT-TYPE
DDboost File Replication Compressed Ratio
1.3.6.1.4.1.19746.1.12.5.1.1.8DDMibTableString32TCread-onlycurrent
ddboostFileReplicationHistory
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.6
ddboostFileReplicationHistoryTable
OBJECT-TYPE
DDBOOST FileReplicationHistory table contains information for File Replication History
1.3.6.1.4.1.19746.1.12.6.1not-accessiblecurrent
ddboostFileReplicationHistoryEntry
OBJECT-TYPE
ddboostFileReplicationHistoryTable Row Entry
1.3.6.1.4.1.19746.1.12.6.1.1not-accessiblecurrent
ddboostFileReplHistoryIndex
OBJECT-TYPE
ddboost FileReplicationHistory Table index
1.3.6.1.4.1.19746.1.12.6.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostFileReplHistoryDirection
OBJECT-TYPE
DDboost File ReplHistory History Direction
1.3.6.1.4.1.19746.1.12.6.1.1.2DDMibTableString32TCread-onlycurrent
ddboostFileReplHistoryNetwork
OBJECT-TYPE
DDBoost File Replication History Network KBytes Sent
1.3.6.1.4.1.19746.1.12.6.1.1.3DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplHistoryPreComp
OBJECT-TYPE
DDBoost File ReplHistory Pre Compressed Kbytes sent
1.3.6.1.4.1.19746.1.12.6.1.1.4DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplHistoryPostComp
OBJECT-TYPE
DDBoost File ReplHistory Post Compressed KBytes
1.3.6.1.4.1.19746.1.12.6.1.1.5DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplHistoryLowBWOpt
OBJECT-TYPE
DDBoost File ReplHistory KBytes after Low Bandwidth optimization
1.3.6.1.4.1.19746.1.12.6.1.1.6DDMibTableString32TCread-onlycurrent
ddboostFileReplHistoryErrors
OBJECT-TYPE
DDBoost File ReplHistory Errors
1.3.6.1.4.1.19746.1.12.6.1.1.7DDMibTrafficBytesTCread-onlycurrent
ddboostFileReplHistoryDate
OBJECT-TYPE
DDboost File ReplHistory Date
1.3.6.1.4.1.19746.1.12.6.1.1.8DDMibDateTCread-onlycurrent
ddboostFileReplHistoryTime
OBJECT-TYPE
DDboost File ReplHistory Time
1.3.6.1.4.1.19746.1.12.6.1.1.9DDMibDateTCread-onlycurrent
ddboostIfGroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.7
ddboostIfGroupConfigTable
OBJECT-TYPE
DDBOOST IfGroupConfig table information for DDBOOST ifGroup Configuration
1.3.6.1.4.1.19746.1.12.7.1not-accessiblecurrent
ddboostIfGroupConfigEntry
OBJECT-TYPE
ddboostIfGroupConfigTable Row Entry
1.3.6.1.4.1.19746.1.12.7.1.1not-accessiblecurrent
ddboostIfGroupConfigIndex
OBJECT-TYPE
ddboost IfGroupConfig Table index
1.3.6.1.4.1.19746.1.12.7.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostIfGroupInterface
OBJECT-TYPE
DDboost ifGroup Interface Name
1.3.6.1.4.1.19746.1.12.7.1.1.2DDMibTableString64TCread-onlycurrent
ddboostAccessClients
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.8
ddboostAccessClientsTable
OBJECT-TYPE
DDBOOST AccessClients table information for DDBOOST Access Client Configuration
1.3.6.1.4.1.19746.1.12.8.1not-accessiblecurrent
ddboostAccessClientsEntry
OBJECT-TYPE
ddboostAccessClientsTable Row Entry
1.3.6.1.4.1.19746.1.12.8.1.1not-accessiblecurrent
ddboostAccessClientsIndex
OBJECT-TYPE
ddboost AccessClients Table index
1.3.6.1.4.1.19746.1.12.8.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostAccessClientsName
OBJECT-TYPE
The DDboost Access clients Name
1.3.6.1.4.1.19746.1.12.8.1.1.2DDMibTableString64TCread-onlycurrent
ddboostAccessClientsEncryStrength
OBJECT-TYPE
The encryption strength that the DDboost Access client is using, possible values are none, medium and high
1.3.6.1.4.1.19746.1.12.8.1.1.3DdboostAccessClientsEncryStrengthTCread-onlycurrent
ddboostAccessClientsAuthMode
OBJECT-TYPE
The Authentication mode that the DDboost Access client is using, possible values are none, one-way, two-way and anonymous
1.3.6.1.4.1.19746.1.12.8.1.1.4DdboostAccessClientsAuthModeTCread-onlycurrent
ddboostOptions
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.9
ddboostOptionsTable
OBJECT-TYPE
DDBOOST Options table
1.3.6.1.4.1.19746.1.12.9.1not-accessiblecurrent
ddboostOptionsEntry
OBJECT-TYPE
ddboostOptionsTable Row Entry
1.3.6.1.4.1.19746.1.12.9.1.1not-accessiblecurrent
ddboostOptionsIndex
OBJECT-TYPE
ddboost Option Table index
1.3.6.1.4.1.19746.1.12.9.1.1.1DDMibTableIndexTCnot-accessiblecurrent
ddboostOptionsName
OBJECT-TYPE
DDboost Option Value Name
1.3.6.1.4.1.19746.1.12.9.1.1.2DDMibTableString64TCread-onlycurrent
ddboostOptionsStatus
OBJECT-TYPE
DDboost Option Status Enabled/Disabled
1.3.6.1.4.1.19746.1.12.9.1.1.3DDMibStatusTCread-onlycurrent
ddboostFileReplicationPerformance
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.12.10
ddboostFileRepliPerfInPreCompKBPerSec
OBJECT-TYPE
DDBOOST File Replication Performance Inbound pre-comp kilobytes per second
1.3.6.1.4.1.19746.1.12.10.1DDMibInteger32TCread-onlycurrent
ddboostFileRepliPerfInNetworkKBPerSec
OBJECT-TYPE
DDBOOST File Replication Performance Inbound network kilobytes per second
1.3.6.1.4.1.19746.1.12.10.2DDMibInteger32TCread-onlycurrent
ddboostFileRepliPerfOutPreCompKBPerSec
OBJECT-TYPE
DDBOOST File Replication Performance Outbound pre-comp kilobytes per second
1.3.6.1.4.1.19746.1.12.10.3DDMibInteger32TCread-onlycurrent
ddboostFileRepliPerfOutNetworkKBPerSec
OBJECT-TYPE
DDBOOST File Replication Performance Outbound network kilobytes per second
1.3.6.1.4.1.19746.1.12.10.4DDMibInteger32TCread-onlycurrent
dataDomainSystem
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13
systemProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13.1
systemSerialNumber
OBJECT-TYPE
Serial Number of the System
1.3.6.1.4.1.19746.1.13.1.1SystemSerialNumberTCread-onlycurrent
systemCurrentTime
OBJECT-TYPE
DDR system's current time
1.3.6.1.4.1.19746.1.13.1.2DDMibTimeStampTCread-onlycurrent
systemVersion
OBJECT-TYPE
DD Version of the System
1.3.6.1.4.1.19746.1.13.1.3DDMibVersionTCread-onlycurrent
systemModelNumber
OBJECT-TYPE
Model Number of the System
1.3.6.1.4.1.19746.1.13.1.4DDMibTableString64TCread-onlycurrent
systemTimeZoneName
OBJECT-TYPE
DDR system's time zone name
1.3.6.1.4.1.19746.1.13.1.5SystemTimeZoneNameTCread-onlycurrent
sysNotes
OBJECT-TYPE
Customer defined notes associated with this DD System.
1.3.6.1.4.1.19746.1.13.1.6SystemNotesTCread-writecurrent
systemHardware
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13.2
systemHardwareTable
OBJECT-TYPE
A table containing entries of SystemHardwareEntry.
1.3.6.1.4.1.19746.1.13.2.1not-accessiblecurrent
systemHardwareEntry
OBJECT-TYPE
systemHardwareTable Row Description
1.3.6.1.4.1.19746.1.13.2.1.1not-accessiblecurrent
systemHardwareIndex
OBJECT-TYPE
System Hardware Row index
1.3.6.1.4.1.19746.1.13.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
systemHardwareSlot
OBJECT-TYPE
System Hardware Slot
1.3.6.1.4.1.19746.1.13.2.1.1.2DDMibInteger32TCread-onlydeprecated
systemHardwareVendor
OBJECT-TYPE
Slot Device Vendor
1.3.6.1.4.1.19746.1.13.2.1.1.3DDMibTableString64TCread-onlycurrent
systemHardwareDevice
OBJECT-TYPE
Slot Device
1.3.6.1.4.1.19746.1.13.2.1.1.4DDMibTableString128TCread-onlycurrent
systemHardwarePorts
OBJECT-TYPE
Slot Ports
1.3.6.1.4.1.19746.1.13.2.1.1.5DDMibTableString128TCread-onlycurrent
systemHardwareSlotName
OBJECT-TYPE
System Hardware Slot Name
1.3.6.1.4.1.19746.1.13.2.1.1.6DisplayString (SIZE(0..3))read-onlycurrent
systemPorts
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13.3
systemPortsTable
OBJECT-TYPE
A table containing entries of SystemPortsEntry.
1.3.6.1.4.1.19746.1.13.3.1not-accessiblecurrent
systemPortsEntry
OBJECT-TYPE
systemPortsTable Row Description
1.3.6.1.4.1.19746.1.13.3.1.1not-accessiblecurrent
systemPortsIndex
OBJECT-TYPE
System Ports Row index
1.3.6.1.4.1.19746.1.13.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
systemPortsPort
OBJECT-TYPE
System Ports Port name
1.3.6.1.4.1.19746.1.13.3.1.1.2DDMibTableString32TCread-onlycurrent
systemPortsConnectionType
OBJECT-TYPE
Port LinkSpeed ConnectionType
1.3.6.1.4.1.19746.1.13.3.1.1.3DDMibTableString64TCread-onlycurrent
systemPortsLinkSpeed
OBJECT-TYPE
system Port LinkSpeed
1.3.6.1.4.1.19746.1.13.3.1.1.4DDMibTableString128TCread-onlycurrent
systemPortsFirmware
OBJECT-TYPE
system ports firmware version
1.3.6.1.4.1.19746.1.13.3.1.1.5DDMibTableString128TCread-onlycurrent
systemPortsHardwareAddress
OBJECT-TYPE
System Port Hardware Address.
1.3.6.1.4.1.19746.1.13.3.1.1.6DDMibTableString64TCread-onlycurrent
systemLicense
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13.4
systemLicenseTable
OBJECT-TYPE
A table containing entries of SystemLicenseEntry.
1.3.6.1.4.1.19746.1.13.4.1not-accessiblecurrent
systemLicenseEntry
OBJECT-TYPE
systemLicenseTable Row Description
1.3.6.1.4.1.19746.1.13.4.1.1not-accessiblecurrent
systemLicenseIndex
OBJECT-TYPE
System License Row index
1.3.6.1.4.1.19746.1.13.4.1.1.1DDMibTableIndexTCnot-accessiblecurrent
systemLicenseKey
OBJECT-TYPE
System License Key
1.3.6.1.4.1.19746.1.13.4.1.1.2DDMibTableString256TCread-onlycurrent
systemLicenseFeature
OBJECT-TYPE
Feature for the license
1.3.6.1.4.1.19746.1.13.4.1.1.3DDMibTableString64TCread-onlycurrent
systemCapacityLicense
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13.4.2
systemCapacityLicenseTable
OBJECT-TYPE
A table containing entries of systemCapacityLicenseEntry.
1.3.6.1.4.1.19746.1.13.4.2.1not-accessiblecurrent
systemCapacityLicenseEntry
OBJECT-TYPE
systemCapacityLicenseTable Row Description
1.3.6.1.4.1.19746.1.13.4.2.1.1not-accessiblecurrent
systemCapacityLicenseIndex
OBJECT-TYPE
systemCapacity License Row index
1.3.6.1.4.1.19746.1.13.4.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
systemCapacityLicenseKey
OBJECT-TYPE
systemCapacity License Key
1.3.6.1.4.1.19746.1.13.4.2.1.1.2DDMibTableString256TCread-onlycurrent
systemCapacityLicenseFeature
OBJECT-TYPE
Capacity Feature for the license
1.3.6.1.4.1.19746.1.13.4.2.1.1.3DDMibTableString64TCread-onlycurrent
systemCapacityLicenseModel
OBJECT-TYPE
Model for Feature of the license
1.3.6.1.4.1.19746.1.13.4.2.1.1.4DDMibTableString32TCread-onlycurrent
systemCapacityLicenseCapacity
OBJECT-TYPE
Capacity of the model
1.3.6.1.4.1.19746.1.13.4.2.1.1.5DDMibTableString32TCread-onlycurrent
systemUser
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.13.5
systemUserTable
OBJECT-TYPE
A table containing entries of SystemUsers.
1.3.6.1.4.1.19746.1.13.5.1not-accessiblecurrent
systemUserEntry
OBJECT-TYPE
SystemUserTable Row Description
1.3.6.1.4.1.19746.1.13.5.1.1not-accessiblecurrent
systemUserIndex
OBJECT-TYPE
SystemUser Row index
1.3.6.1.4.1.19746.1.13.5.1.1.1DDMibTableIndexTCnot-accessiblecurrent
systemUserName
OBJECT-TYPE
SystemUser Name
1.3.6.1.4.1.19746.1.13.5.1.1.2DDMibTableString128TCread-onlycurrent
systemUserUID
OBJECT-TYPE
SystemUser UID
1.3.6.1.4.1.19746.1.13.5.1.1.3DDMibInteger32TCread-onlycurrent
systemUserRole
OBJECT-TYPE
SystemUser Role
1.3.6.1.4.1.19746.1.13.5.1.1.4DDMibTableString32TCread-onlycurrent
systemUserStatus
OBJECT-TYPE
SystemUsers Status
1.3.6.1.4.1.19746.1.13.5.1.1.5DDMibTableString32TCread-onlycurrent
systemActiveUserTable
OBJECT-TYPE
A table containing entries of SystemActiveUsers.
1.3.6.1.4.1.19746.1.13.5.2not-accessiblecurrent
systemActiveUserEntry
OBJECT-TYPE
SystemActiveUserTable Row Description
1.3.6.1.4.1.19746.1.13.5.2.1not-accessiblecurrent
systemActiveUserIndex
OBJECT-TYPE
SystemActiveUser Row index
1.3.6.1.4.1.19746.1.13.5.2.1.1DDMibTableIndexTCnot-accessiblecurrent
systemActiveUserName
OBJECT-TYPE
SystemActiveUser Name
1.3.6.1.4.1.19746.1.13.5.2.1.2DDMibTableString128TCread-onlycurrent
systemActiveUserIdleTime
OBJECT-TYPE
SystemActiveUser idle time
1.3.6.1.4.1.19746.1.13.5.2.1.3DDMibTableString32TCread-onlycurrent
systemActiveUserLoginTime
OBJECT-TYPE
SystemActiveUser login time
1.3.6.1.4.1.19746.1.13.5.2.1.4DDMibTableString32TCread-onlycurrent
systemActiveUserLoginFrom
OBJECT-TYPE
SystemActiveUser login from
1.3.6.1.4.1.19746.1.13.5.2.1.5DDMibTableString32TCread-onlycurrent
systemActiveUserTty
OBJECT-TYPE
SystemActiveUsers Tty
1.3.6.1.4.1.19746.1.13.5.2.1.6DDMibTableString32TCread-onlycurrent
art
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.14
artConfig
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.14.1
artConfigTable
OBJECT-TYPE
A table containing entries of artConfigEntry.
1.3.6.1.4.1.19746.1.14.1.1not-accessiblecurrent
artConfigEntry
OBJECT-TYPE
artConfigTable Row Description
1.3.6.1.4.1.19746.1.14.1.1.1not-accessiblecurrent
artConfigIndex
OBJECT-TYPE
art Config index
1.3.6.1.4.1.19746.1.14.1.1.1.1DDMibTableIndexTCnot-accessiblecurrent
artConfigStatus
OBJECT-TYPE
art Config Status
1.3.6.1.4.1.19746.1.14.1.1.1.2DDMibTableEnabledTCread-onlycurrent
artConfigMigrationSchedule
OBJECT-TYPE
art Config Migration Schedule
1.3.6.1.4.1.19746.1.14.1.1.1.3DDMibTableString128TCread-onlycurrent
artConfigDefaultAge
OBJECT-TYPE
art Config Default Age threshold migration policy
1.3.6.1.4.1.19746.1.14.1.1.1.4DDMibInteger32TCread-onlycurrent
artConfigFileSystemClean
OBJECT-TYPE
art Config file System Clean Required
1.3.6.1.4.1.19746.1.14.1.1.1.5DDMibTableEnabledTCread-onlycurrent
artConfigCompression
OBJECT-TYPE
art Config local compression
1.3.6.1.4.1.19746.1.14.1.1.1.6DDMibTableString32TCread-onlycurrent
artMigrationSchedule
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.14.2
artMigrationScheduleTable
OBJECT-TYPE
A table containing entries of artMigrationScheduleEntry.
1.3.6.1.4.1.19746.1.14.2.1not-accessiblecurrent
artMigrationScheduleEntry
OBJECT-TYPE
artMigrationScheduleTable Row Description
1.3.6.1.4.1.19746.1.14.2.1.1not-accessiblecurrent
artMigrationScheduleIndex
OBJECT-TYPE
art MigrationScheduleindex
1.3.6.1.4.1.19746.1.14.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
artMigrationScheduleSchedule
OBJECT-TYPE
art MigrationSchedule Schedule
1.3.6.1.4.1.19746.1.14.2.1.1.2DDMibTableString512TCread-onlycurrent
artMigrationScheduleStatus
OBJECT-TYPE
art MigrationSchedule Status
1.3.6.1.4.1.19746.1.14.2.1.1.3DDMibStatusTCread-onlycurrent
artMigrationPolicy
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.14.3
artMigrationPolicyTable
OBJECT-TYPE
A table containing entries of artMigrationPolicyEntry.
1.3.6.1.4.1.19746.1.14.3.1not-accessiblecurrent
artMigrationPolicyEntry
OBJECT-TYPE
artMigrationPolicyTable Row Description
1.3.6.1.4.1.19746.1.14.3.1.1not-accessiblecurrent
artMigrationPolicyIndex
OBJECT-TYPE
art MigrationPolicy index
1.3.6.1.4.1.19746.1.14.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
artMigrationPolicyMtreeName
OBJECT-TYPE
art MigrationPolicy Mtree Name
1.3.6.1.4.1.19746.1.14.3.1.1.2DDMibTableString256TCread-onlycurrent
artMigrationPolicyDefaultAge
OBJECT-TYPE
art MigrationPolicy Default Age
1.3.6.1.4.1.19746.1.14.3.1.1.3DDMibInteger32TCread-onlycurrent
mtree
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.15
mtreeCompression
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.15.1
mtreeCompressionTable
OBJECT-TYPE
A table containing entries of mtreeCompressionEntry.
1.3.6.1.4.1.19746.1.15.1.1not-accessiblecurrent
mtreeCompressionEntry
OBJECT-TYPE
mtreeCompressionTable Row Description
1.3.6.1.4.1.19746.1.15.1.1.1not-accessiblecurrent
mtreeCompressionIndex
OBJECT-TYPE
mtree Compression index
1.3.6.1.4.1.19746.1.15.1.1.1.1DDMibTableIndexTCnot-accessiblecurrent
mtreeCompressionMtreePath
OBJECT-TYPE
mtree Compression Mtree Path
1.3.6.1.4.1.19746.1.15.1.1.1.2DDMibTableString512TCread-onlycurrent
mtreeCompressionPreCompGib
OBJECT-TYPE
mtree Compression Pre comp giga bytes
1.3.6.1.4.1.19746.1.15.1.1.1.3DDMibTableSizeGibTCread-onlycurrent
mtreeCompressionPostCompGib
OBJECT-TYPE
mtree Compression Post Comp Giga Bytes
1.3.6.1.4.1.19746.1.15.1.1.1.4DDMibTableSizeGibTCread-onlycurrent
mtreeCompressionGlobalCompFactor
OBJECT-TYPE
mtree Compression Global Comp Factor
1.3.6.1.4.1.19746.1.15.1.1.1.5DDMibCompressionFactorTCread-onlycurrent
mtreeCompressionLocalCompFactor
OBJECT-TYPE
mtree Compression Local Comp Factor
1.3.6.1.4.1.19746.1.15.1.1.1.6DDMibCompressionFactorTCread-onlycurrent
mtreeCompressionPostTotalCompFactor
OBJECT-TYPE
mtree Compression Total Comp Factor
1.3.6.1.4.1.19746.1.15.1.1.1.7DDMibCompressionFactorTCread-onlycurrent
mtreeCompressionTimePeriod
OBJECT-TYPE
mtree Compression Time Period
1.3.6.1.4.1.19746.1.15.1.1.1.8DDMibTableString128TCread-onlycurrent
mtreeList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.15.2
mtreeListTable
OBJECT-TYPE
A table containing entries of mtreeListEntry.
1.3.6.1.4.1.19746.1.15.2.1not-accessiblecurrent
mtreeListEntry
OBJECT-TYPE
mtreeListTable Row Description
1.3.6.1.4.1.19746.1.15.2.1.1not-accessiblecurrent
mtreeListIndex
OBJECT-TYPE
mtree List index
1.3.6.1.4.1.19746.1.15.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
mtreeListMtreeName
OBJECT-TYPE
mtree List Mtree Name
1.3.6.1.4.1.19746.1.15.2.1.1.2DDMibTableString512TCread-onlycurrent
mtreeListPreCompGib
OBJECT-TYPE
mtree List Pre comp giga bytes
1.3.6.1.4.1.19746.1.15.2.1.1.3DDMibTableSizeGibTCread-onlycurrent
mtreeListStatus
OBJECT-TYPE
mtree List Status
1.3.6.1.4.1.19746.1.15.2.1.1.4MtreeListStatusTCread-onlycurrent
mtreeRetentionLock
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.15.4
mtreeRetentionLockTable
OBJECT-TYPE
A table containing entries of mtreeRetentionLockEntry.
1.3.6.1.4.1.19746.1.15.4.1not-accessiblecurrent
mtreeRetentionLockEntry
OBJECT-TYPE
mtreeRetentionLockTable Row Description
1.3.6.1.4.1.19746.1.15.4.1.1not-accessiblecurrent
mtreeRetentionLockIndex
OBJECT-TYPE
mtree RetentionLock index
1.3.6.1.4.1.19746.1.15.4.1.1.1DDMibTableIndexTCnot-accessiblecurrent
mtreeRetentionLockMtreeName
OBJECT-TYPE
mtree RetentionLock Mtree Name
1.3.6.1.4.1.19746.1.15.4.1.1.2DDMibTableString512TCread-onlycurrent
mtreeRetentionLockStatus
OBJECT-TYPE
mtree RetentionLock Status
1.3.6.1.4.1.19746.1.15.4.1.1.3MtreeRetentionLockStatusTCread-onlycurrent
mtreeRetentionLockUUID
OBJECT-TYPE
mtree RetentionLock UUID
1.3.6.1.4.1.19746.1.15.4.1.1.4DDMibTableString32TCread-onlycurrent
mtreeRetentionLockMinRetentionPeriod
OBJECT-TYPE
mtree RetentionLock Minimum Retention Period
1.3.6.1.4.1.19746.1.15.4.1.1.5DDMibTableString32TCread-onlycurrent
mtreeRetentionLockMaxRetentionPeriod
OBJECT-TYPE
mtree RetentionLock Maximum Retention Period
1.3.6.1.4.1.19746.1.15.4.1.1.6DDMibTableString32TCread-onlycurrent
storage
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.16
enclosure
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.17
enclosureList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.17.1
enclosureListTable
OBJECT-TYPE
A table containing entries of EnclosureListEntry.
1.3.6.1.4.1.19746.1.17.1.1not-accessiblecurrent
enclosureListEntry
OBJECT-TYPE
enclosure List Row Description
1.3.6.1.4.1.19746.1.17.1.1.1not-accessiblecurrent
enclosureListIndex
OBJECT-TYPE
enclosure List Row index
1.3.6.1.4.1.19746.1.17.1.1.1.1DDMibTableIndexTCnot-accessiblecurrent
enclosureListNum
OBJECT-TYPE
enclosure Number
1.3.6.1.4.1.19746.1.17.1.1.1.2DDMibInteger32TCread-onlycurrent
enclosureListModel
OBJECT-TYPE
enclosure model
1.3.6.1.4.1.19746.1.17.1.1.1.3DDMibTableString64TCread-onlycurrent
enclosureListSerialNum
OBJECT-TYPE
enclosure serial number
1.3.6.1.4.1.19746.1.17.1.1.1.4DDMibTableString128TCread-onlycurrent
enclosureListOemName
OBJECT-TYPE
enclosure oem name
1.3.6.1.4.1.19746.1.17.1.1.1.5DDMibTableString128TCread-onlycurrent
enclosureListOemValue
OBJECT-TYPE
enclosure oem value
1.3.6.1.4.1.19746.1.17.1.1.1.6DDMibTableString128TCread-onlycurrent
enclosureListCapacity
OBJECT-TYPE
enclosure Capacity
1.3.6.1.4.1.19746.1.17.1.1.1.7DDMibTableString64TCread-onlycurrent
enclosurePack
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.17.2
enclosurePackTable
OBJECT-TYPE
A table containing entries of EnclosurePackEntry.
1.3.6.1.4.1.19746.1.17.2.1not-accessiblecurrent
enclosurePackEntry
OBJECT-TYPE
enclosure Pack Row Description
1.3.6.1.4.1.19746.1.17.2.1.1not-accessiblecurrent
enclosurePackID
OBJECT-TYPE
Pack information for the enclosure. Applicable to enclosures with packs such as ES60, and not for ES20 or ES30.
1.3.6.1.4.1.19746.1.17.2.1.1.1DDMibTableIndexTCread-onlycurrent
network
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.18
dns
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.18.1
dnsTable
OBJECT-TYPE
A table containing entries of dnsEntry.
1.3.6.1.4.1.19746.1.18.1.1not-accessiblecurrent
dnsEntry
OBJECT-TYPE
DNS Table Row Description
1.3.6.1.4.1.19746.1.18.1.1.1not-accessiblecurrent
dnsIndex
OBJECT-TYPE
DNS Table Row index
1.3.6.1.4.1.19746.1.18.1.1.1.1DDMibTableIndexTCnot-accessiblecurrent
dnsServer
OBJECT-TYPE
DNS Server
1.3.6.1.4.1.19746.1.18.1.1.1.2DDMibTableString32TCread-onlycurrent
searchDomains
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.18.2
searchDomainsTable
OBJECT-TYPE
A table containing entries of searchDomainsEntry.
1.3.6.1.4.1.19746.1.18.2.1not-accessiblecurrent
searchDomainsEntry
OBJECT-TYPE
searchDomains Table Row Description
1.3.6.1.4.1.19746.1.18.2.1.1not-accessiblecurrent
searchDomainsIndex
OBJECT-TYPE
searchDomains Table Row index
1.3.6.1.4.1.19746.1.18.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
searchDomainsName
OBJECT-TYPE
searchDomains Name
1.3.6.1.4.1.19746.1.18.2.1.1.2DDMibTableString128TCread-onlycurrent
snmpTrapHosts
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.18.3
snmpTrapHostsTable
OBJECT-TYPE
A table containing entries of snmp Trap Hosts.
1.3.6.1.4.1.19746.1.18.3.1not-accessiblecurrent
snmpTrapHostsEntry
OBJECT-TYPE
snmpTrapHosts Table Row Description
1.3.6.1.4.1.19746.1.18.3.1.1not-accessiblecurrent
snmpTrapHostsIndex
OBJECT-TYPE
snmpTrapHosts Table Row index
1.3.6.1.4.1.19746.1.18.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
snmpTrapHostsName
OBJECT-TYPE
snmp Trap Hosts Name
1.3.6.1.4.1.19746.1.18.3.1.1.2DDMibTableString256TCread-onlycurrent
snmpTrapHostsVersion
OBJECT-TYPE
snmp Trap Hosts Version
1.3.6.1.4.1.19746.1.18.3.1.1.3DDMibTableString32TCread-onlycurrent
nis
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.18.4
nisDomain
OBJECT-TYPE
NIS domain
1.3.6.1.4.1.19746.1.18.4.1DDMibTableString1024TCread-onlycurrent
nisServers
OBJECT-TYPE
NIS servers
1.3.6.1.4.1.19746.1.18.4.2DDMibTableString1024TCread-onlycurrent
nisAdminGroups
OBJECT-TYPE
NIS admin groups
1.3.6.1.4.1.19746.1.18.4.3DDMibTableString1024TCread-onlycurrent
nisUserGroups
OBJECT-TYPE
NIS user groups
1.3.6.1.4.1.19746.1.18.4.4DDMibTableString1024TCread-onlycurrent
nisBackupOperatorGroups
OBJECT-TYPE
NIS backup operator groups
1.3.6.1.4.1.19746.1.18.4.5DDMibTableString1024TCread-onlycurrent
nisEnabled
OBJECT-TYPE
NIS enabled or not
1.3.6.1.4.1.19746.1.18.4.6DDMibTableEnabledTCread-onlycurrent
nisStatus
OBJECT-TYPE
NIS status
1.3.6.1.4.1.19746.1.18.4.7DDMibTableString1024TCread-onlycurrent
ddms
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.19
managedSystem
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.19.1
managedSystemTable
OBJECT-TYPE
A table containing entries of managed systems.
1.3.6.1.4.1.19746.1.19.1.1not-accessiblecurrent
managedSystemEntry
OBJECT-TYPE
managedSystemTable Row Description
1.3.6.1.4.1.19746.1.19.1.1.1not-accessiblecurrent
managedSystemIndex
OBJECT-TYPE
managed system Row index
1.3.6.1.4.1.19746.1.19.1.1.1.1DDMibTableIndexTCnot-accessiblecurrent
managedSystemHostname
OBJECT-TYPE
managed system hostname
1.3.6.1.4.1.19746.1.19.1.1.1.2DDMibTableString256TCread-onlycurrent
managedSystemSerial
OBJECT-TYPE
managed system serial number
1.3.6.1.4.1.19746.1.19.1.1.1.3DDMibTableString32TCread-onlycurrent
managedSystemState
OBJECT-TYPE
managed system state
1.3.6.1.4.1.19746.1.19.1.1.1.4DDMibTableString32TCread-onlycurrent
managedSystemStatus
OBJECT-TYPE
managed system status
1.3.6.1.4.1.19746.1.19.1.1.1.5DDMibTableString32TCread-onlycurrent
managedSystemDDOSVersion
OBJECT-TYPE
managed system DDOS version
1.3.6.1.4.1.19746.1.19.1.1.1.6DDMibTableString32TCread-onlycurrent
managedSystemHDSyncTime
OBJECT-TYPE
managed system historial data last sync time
1.3.6.1.4.1.19746.1.19.1.1.1.7DDMibTableString64TCread-onlycurrent
managedSystemCDSyncTime
OBJECT-TYPE
managed system system current data last sync time
1.3.6.1.4.1.19746.1.19.1.1.1.8DDMibTableString64TCread-onlycurrent
taskHistory
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.19.2
taskHistoryTable
OBJECT-TYPE
A table containing entries of TaskHistoryEntry.
1.3.6.1.4.1.19746.1.19.2.1not-accessiblecurrent
taskHistoryEntry
OBJECT-TYPE
taskHistoryEntry Row Description
1.3.6.1.4.1.19746.1.19.2.1.1not-accessiblecurrent
taskHistoryIndex
OBJECT-TYPE
Task History Row index
1.3.6.1.4.1.19746.1.19.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
taskHistoryUser
OBJECT-TYPE
Task History User
1.3.6.1.4.1.19746.1.19.2.1.1.2DDMibTableString64TCread-onlycurrent
taskHistoryID
OBJECT-TYPE
Task History ID
1.3.6.1.4.1.19746.1.19.2.1.1.3DDMibTableString64TCread-onlycurrent
taskHistoryParent
OBJECT-TYPE
Task History Parent
1.3.6.1.4.1.19746.1.19.2.1.1.4DDMibTableString64TCread-onlycurrent
taskHistoryName
OBJECT-TYPE
Task History Name
1.3.6.1.4.1.19746.1.19.2.1.1.5DDMibTableString64TCread-onlycurrent
taskHistoryState
OBJECT-TYPE
Task History State
1.3.6.1.4.1.19746.1.19.2.1.1.6DDMibTableString64TCread-onlycurrent
taskHistoryStartTime
OBJECT-TYPE
Task History Start Time
1.3.6.1.4.1.19746.1.19.2.1.1.7DDMibTableString64TCread-onlycurrent
taskHistoryDuration
OBJECT-TYPE
Task History Duration
1.3.6.1.4.1.19746.1.19.2.1.1.8DDMibTableString64TCread-onlycurrent
taskActive
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.19.3
taskActiveTable
OBJECT-TYPE
A table containing entries of TaskActiveEntry.
1.3.6.1.4.1.19746.1.19.3.1not-accessiblecurrent
taskActiveEntry
OBJECT-TYPE
taskActiveEntry Row Description
1.3.6.1.4.1.19746.1.19.3.1.1not-accessiblecurrent
taskActiveIndex
OBJECT-TYPE
Task Active Row index
1.3.6.1.4.1.19746.1.19.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
taskActiveUser
OBJECT-TYPE
Task Active User
1.3.6.1.4.1.19746.1.19.3.1.1.2DDMibTableString64TCread-onlycurrent
taskActiveID
OBJECT-TYPE
Task Active ID
1.3.6.1.4.1.19746.1.19.3.1.1.3DDMibTableString64TCread-onlycurrent
taskActiveParent
OBJECT-TYPE
Task Active Parent
1.3.6.1.4.1.19746.1.19.3.1.1.4DDMibTableString64TCread-onlycurrent
taskActiveName
OBJECT-TYPE
Task Active Name
1.3.6.1.4.1.19746.1.19.3.1.1.5DDMibTableString64TCread-onlycurrent
taskActiveState
OBJECT-TYPE
Task Active State
1.3.6.1.4.1.19746.1.19.3.1.1.6DDMibTableString64TCread-onlycurrent
taskActiveStartTime
OBJECT-TYPE
Task Active Start Time
1.3.6.1.4.1.19746.1.19.3.1.1.7DDMibTableString64TCread-onlycurrent
taskActiveDuration
OBJECT-TYPE
Task Active Duration
1.3.6.1.4.1.19746.1.19.3.1.1.8DDMibTableString64TCread-onlycurrent
smt
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20
smtProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.1
smtStatus
OBJECT-TYPE
The status of the Secure Multi-Tenancy (SMT) feature on a DD System, which enables storage consolidation for multiple tenants on the same appliance. Through this feature, data and control paths on the DD System are logically secured, isolated and confined, creating secure and isolated logical partitions for each tenant- unit within the same appliance.
1.3.6.1.4.1.19746.1.20.1.1SmtStatusTCread-onlycurrent
tenantUnitList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.2
tenantUnitListTable
OBJECT-TYPE
This table contains information about the tenant-units within a DD System that has the Secure Multi-Tenancy (SMT) feature enabled. It includes the tenant-unit name, the number of tenant specific Management users that have been added, the number of Mtree(s)/ DDBoost Storage Units assigned, and whether Tenant-self-service mode is enabled.
1.3.6.1.4.1.19746.1.20.2.1not-accessiblecurrent
tenantUnitListEntry
OBJECT-TYPE
Information about a tenant-unit within a DD System.
1.3.6.1.4.1.19746.1.20.2.1.1not-accessiblecurrent
tenantUnitListIdx
OBJECT-TYPE
The index of a tenant-unit (SMT management object). This index uniquely identifies the tenant-unit at a given time.
1.3.6.1.4.1.19746.1.20.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
tenantUnitListName
OBJECT-TYPE
The name of a tenant-unit. A tenant-unit name consists of letters, numbers, no special characters and can have a length of 254 characters.
1.3.6.1.4.1.19746.1.20.2.1.1.2DDMibTableString256TCread-onlycurrent
tenantUnitListNumberOfMgmtUsers
OBJECT-TYPE
The number of Tenant specific Management users which have been added to a tenant-unit.
1.3.6.1.4.1.19746.1.20.2.1.1.3DDMibInteger32TCread-onlycurrent
tenantUnitListNumberOfMtrees
OBJECT-TYPE
The number of Mtree(s) which have been assigned to a tenant-unit.
1.3.6.1.4.1.19746.1.20.2.1.1.4DDMibInteger32TCread-onlycurrent
tenantUnitListNumberOfDdboostStus
OBJECT-TYPE
The number of DDBoost Storage Units which have been assigned to a tenant-unit.
1.3.6.1.4.1.19746.1.20.2.1.1.5DDMibInteger32TCread-onlycurrent
tenantUnitListTenantSelfServiceMode
OBJECT-TYPE
Status of Tenant Self Service Mode. If enabled, administrative access to each tenant is allowed, so that they can monitor and configure their data protection implementation, within the bounds of their allocated objects and features.
1.3.6.1.4.1.19746.1.20.2.1.1.6SmtStatusTCread-onlycurrent
tenantUnitListParentTenantName
OBJECT-TYPE
The tenant name that a tenant-unit is associated with.
1.3.6.1.4.1.19746.1.20.2.1.1.7DDMibTableString256TCread-onlycurrent
tenantUnitListType
OBJECT-TYPE
The Mtree type of a tenant-unit.
1.3.6.1.4.1.19746.1.20.2.1.1.8DDMibTableString256TCread-onlycurrent
tenantUnitListSecurityMode
OBJECT-TYPE
The security mode of a tenant-unit.
1.3.6.1.4.1.19746.1.20.2.1.1.9TenantUnitSecurityModeTCread-onlycurrent
tenantUnitListNumberOfMgmtGroups
OBJECT-TYPE
The number of Tenant specific Management groups which have been added to a tenant-unit.
1.3.6.1.4.1.19746.1.20.2.1.1.10DDMibInteger32TCread-onlycurrent
tenantUnitMgmtUserList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.3
tenantUnitMgmtUserListTable
OBJECT-TYPE
This table contains information about the tenant specific management users that have been added to a tenant-unit. Such users may be limited by their role and scope to operate a limited set of operations only on the objects which are assigned-to/associated with their tenant-units. Tenant specific management users may have limited administrative and management capabilities.
1.3.6.1.4.1.19746.1.20.3.1not-accessiblecurrent
tenantUnitMgmtUserListEntry
OBJECT-TYPE
Information about the management users that have been added to a tenant-unit.
1.3.6.1.4.1.19746.1.20.3.1.1not-accessiblecurrent
tenantUnitMgmtUserListUserName
OBJECT-TYPE
The name of a management user which has been added to a tenant- unit. Users may be limited by their roles and may have limited administrative and management capabilities.
1.3.6.1.4.1.19746.1.20.3.1.1.2DDMibString96TCnot-accessiblecurrent
tenantUnitMgmtUserListUserRole
OBJECT-TYPE
The role of a management user. Roles include tenant-admin and tenant-user.
1.3.6.1.4.1.19746.1.20.3.1.1.3TenantUnitMgmtUserListUserRoleTCread-onlycurrent
tenantUnitMtreeList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.4
tenantUnitMtreeListTable
OBJECT-TYPE
This table contains information about the mtree(s) which have been assigned to a tenant-unit. Mtree logical quotas for soft-limit and hard-limit may be imposed on a tenant-unit and will allow provisioning space for each tenant on a DD System. Data access may be contained within the mtrees belonging to an tenant-unit.
1.3.6.1.4.1.19746.1.20.4.1not-accessiblecurrent
tenantUnitMtreeListEntry
OBJECT-TYPE
Information about an mtree associated with a tenant-unit within a DD System.
1.3.6.1.4.1.19746.1.20.4.1.1not-accessiblecurrent
tenantUnitMtreeListMtreeName
OBJECT-TYPE
The name of an mtree that has been assigned to a particular tenant-unit. One tenant-unit (SMT management object) may have multiple mtrees associated with it.
1.3.6.1.4.1.19746.1.20.4.1.1.2DDMibString96TCread-onlycurrent
tenantUnitDdboostStuList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.5
tenantUnitDdboostStuListTable
OBJECT-TYPE
This table contains information about the DDBoost Storage Units that have been assigned to a tenant-unit. Logical quotas for soft- limit and hard-limit may be imposed on a tenant-unit and will allow provisioning space for each tenant on a DD System. Data access may be contained within the DDBoost Storage Units belonging to a tenant-unit.
1.3.6.1.4.1.19746.1.20.5.1not-accessiblecurrent
tenantUnitDdboostStuListEntry
OBJECT-TYPE
Information about a DDBoost Storage Unit associated with a tenant- unit.
1.3.6.1.4.1.19746.1.20.5.1.1not-accessiblecurrent
tenantUnitDdboostStuListStuName
OBJECT-TYPE
The name of a DDBoost Storage Unit associated with a tenant-unit. One tenant-unit (SMT management object) may have multiple DDBoost Storage Units associated with it.
1.3.6.1.4.1.19746.1.20.5.1.1.2DDMibString96TCread-onlycurrent
tenantUnitAdminIpInfo
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.6
tenantUnitAdminIpInfoTable
OBJECT-TYPE
This table provides IP address related information about a tenant-unit administrator.
1.3.6.1.4.1.19746.1.20.6.1not-accessiblecurrent
tenantUnitAdminIpInfoEntry
OBJECT-TYPE
An entry of this table represents one set of IP information about a tenant-unit administrator.
1.3.6.1.4.1.19746.1.20.6.1.1not-accessiblecurrent
tenantUnitAdminIpInfoAddr
OBJECT-TYPE
The IP address (IPv4/IPv6) of a tenant-unit administrator.
1.3.6.1.4.1.19746.1.20.6.1.1.2DDMibString96TCnot-accessiblecurrent
tenantUnitAdminIpInfoType
OBJECT-TYPE
The IP addresss type of a tenant-unit administrator. Possible values: local or remote.
1.3.6.1.4.1.19746.1.20.6.1.1.3DDMibString96TCread-onlycurrent
tenantInfo
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.7
tenantInfoTable
OBJECT-TYPE
This table provides tenant information for the Secure Multi-Tenancy (SMT) feature.
1.3.6.1.4.1.19746.1.20.7.1not-accessiblecurrent
tenantInfoEntry
OBJECT-TYPE
An entry represents one instance about a tenant that is configured on DD system.
1.3.6.1.4.1.19746.1.20.7.1.1not-accessiblecurrent
tenantInfoIdx
OBJECT-TYPE
The index into this table indentifying a particular tenant object.
1.3.6.1.4.1.19746.1.20.7.1.1.1DDMibTableIndexTCnot-accessiblecurrent
tenantInfoTenantName
OBJECT-TYPE
The name of this tenant.
1.3.6.1.4.1.19746.1.20.7.1.1.2DDMibString96TCread-onlycurrent
tenantInfoTenantUnitTable
OBJECT-TYPE
This table provides information about the tenant-unit(s) that are associated with this tenant.
1.3.6.1.4.1.19746.1.20.7.2not-accessiblecurrent
tenantInfoTenantUnitEntry
OBJECT-TYPE
An entry represents information about one tenant-unit that is associated with a particular tenant.
1.3.6.1.4.1.19746.1.20.7.2.1not-accessiblecurrent
tenantInfoTenantUnitName
OBJECT-TYPE
The name of tenant-unit that is associated with this tenant.
1.3.6.1.4.1.19746.1.20.7.2.1.2DDMibString96TCread-onlycurrent
tenantUnitMgmtGroupList
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.20.8
tenantUnitMgmtGroupListTable
OBJECT-TYPE
This table contains information about the tenant specific management groups that have been added to a tenant-unit. Such groups may be limited by their role and scope to operate a limited set of operations only on the objects which are assigned-to/associated with their tenant-units. Tenant specific management groups may have limited administrative and management capabilities.
1.3.6.1.4.1.19746.1.20.8.1not-accessiblecurrent
tenantUnitMgmtGroupListEntry
OBJECT-TYPE
Information about the management groups that have been added to a tenant-unit.
1.3.6.1.4.1.19746.1.20.8.1.1not-accessiblecurrent
tenantUnitMgmtGroupListGroupName
OBJECT-TYPE
The name of a management group which has been added to a tenant- unit. Groups may be limited by their roles and may have limited administrative and management capabilities.
1.3.6.1.4.1.19746.1.20.8.1.1.2DDMibString96TCnot-accessiblecurrent
tenantUnitMgmtGroupListGroupRole
OBJECT-TYPE
The role of a management group. Roles include tenant-admin and tenant-group.
1.3.6.1.4.1.19746.1.20.8.1.1.3TenantUnitMgmtUserListUserRoleTCread-onlycurrent
tenantUnitMgmtGroupListGroupType
OBJECT-TYPE
The type of a management group. Types include all, local, ad, nis and ldap.
1.3.6.1.4.1.19746.1.20.8.1.1.4TenantUnitMgmtGroupTypeTCread-onlycurrent
quota
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.21
quotaProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.21.1
quotaCapacityStatus
OBJECT-TYPE
The status of the quota capacity property on a Data Domain System. If enabled quota limits are enforced and administrators can control the logical space consumed on a per-Mtree basis.
1.3.6.1.4.1.19746.1.21.1.1DDStatusTCread-onlycurrent
quotaCapacity
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.21.2
quotaCapacityTable
OBJECT-TYPE
This table lists quota capacities for Mtrees and Storage-units. It provides information such as the Mtree name, the Pre-Comp (MiB) size, Soft-Limit (MiB), and Hard-Limit (MiB). It is comprised of entries of quotaCapacityEntry.
1.3.6.1.4.1.19746.1.21.2.1not-accessiblecurrent
quotaCapacityEntry
OBJECT-TYPE
An entry containing quota information for Mtrees and Storage-units on the DD System.
1.3.6.1.4.1.19746.1.21.2.1.1not-accessiblecurrent
quotaCapacityIndex
OBJECT-TYPE
The index of an Mtree or Storage-unit. This index uniquely identifies the entry at a given time.
1.3.6.1.4.1.19746.1.21.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
quotaCapacityMtreeName
OBJECT-TYPE
The name of the Mtree or Storage-unit for which quota capacity information is provided.
1.3.6.1.4.1.19746.1.21.2.1.1.2DDMibTableString512TCread-onlycurrent
quotaCapacityPreCompMiB
OBJECT-TYPE
The Pre-Comp (MiB) size of the Mtree or Storage-unit. This is the amount of data written before compression.
1.3.6.1.4.1.19746.1.21.2.1.1.3DDMibTableSizeMiBTCread-onlycurrent
quotaCapacitySoftLimitMiB
OBJECT-TYPE
The Soft-Limit (MiB) quota for the Mtree or Storage-unit. Soft quotas provide only an alert when quota limits are reached, and the backup job is allowed to complete so that the administrator can take corrective actions that are convenient to the organization.
1.3.6.1.4.1.19746.1.21.2.1.1.4DDMibTableSizeMiBTCread-onlycurrent
quotaCapacityHardLimitMiB
OBJECT-TYPE
The Hard-Limit (MiB) quota for the Mtree or Storage-unit. Hard quotas provide a stricter enforcement model than soft quotas by failing the backup jobs or I/O when quota limits are reached.
1.3.6.1.4.1.19746.1.21.2.1.1.5DDMibTableSizeMiBTCread-onlycurrent
quotaCapacityTenantUnit
OBJECT-TYPE
The Tenant-unit to which this Mtree or Storage-unit is assigned. Tenant-units allow for secure and isolated logical partitions within an appliance and are part of the Secure Multi-Tenancy (SMT) feature.
1.3.6.1.4.1.19746.1.21.2.1.1.6DDMibTableString512TCread-onlycurrent
highAvailability
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.22
highAvailabilityStatus
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.22.1
haSystemName
OBJECT-TYPE
High Availability System Name
1.3.6.1.4.1.19746.1.22.1.1DDMibTableString128TCread-onlycurrent
haSystemStatus
OBJECT-TYPE
High Availability System Status
1.3.6.1.4.1.19746.1.22.1.2HaSystemStatusTCread-onlycurrent
haInterconnectStatus
OBJECT-TYPE
High Availability Interconnect Status
1.3.6.1.4.1.19746.1.22.1.3HaStatusTCread-onlycurrent
haPrimaryHeartbeatStatus
OBJECT-TYPE
High Availability Primary Heartbeat Status
1.3.6.1.4.1.19746.1.22.1.4HaStatusTCread-onlycurrent
haExternalLanHeartbeatStatus
OBJECT-TYPE
High Availability External LAN Heartbeat Status
1.3.6.1.4.1.19746.1.22.1.5HaStatusTCread-onlycurrent
haHardwareCompatibilityCheck
OBJECT-TYPE
High Availability Hardware Compatibility Check
1.3.6.1.4.1.19746.1.22.1.6HaStatusTCread-onlycurrent
haSoftwareVersionCheck
OBJECT-TYPE
High Availability Software Version Check
1.3.6.1.4.1.19746.1.22.1.7HaStatusTCread-onlycurrent
highAvailabilityNode
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.22.2
highAvailabilityNodeTable
OBJECT-TYPE
This table provides high availability node information.
1.3.6.1.4.1.19746.1.22.2.1not-accessiblecurrent
highAvailabilityNodeEntry
OBJECT-TYPE
An entry represents one instance about a high availability node.
1.3.6.1.4.1.19746.1.22.2.1.1not-accessiblecurrent
highAvailabilityNodeIdx
OBJECT-TYPE
The index into this table indentifying a particular node.
1.3.6.1.4.1.19746.1.22.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
highAvailabilityNodeName
OBJECT-TYPE
The name of a high availability node.
1.3.6.1.4.1.19746.1.22.2.1.1.2DDMibTableString128TCread-onlycurrent
highAvailabilityNodeId
OBJECT-TYPE
The ID of a high availability node.
1.3.6.1.4.1.19746.1.22.2.1.1.3DDMibTableString128TCread-onlycurrent
highAvailabilityNodeRole
OBJECT-TYPE
The role of a high availability node.
1.3.6.1.4.1.19746.1.22.2.1.1.4DDMibTableString128TCread-onlycurrent
highAvailabilityNodeState
OBJECT-TYPE
The state of a high availability node.
1.3.6.1.4.1.19746.1.22.2.1.1.5DDMibTableString128TCread-onlycurrent
highAvailabilityNodeHealth
OBJECT-TYPE
The health of the high availability node's resources.
1.3.6.1.4.1.19746.1.22.2.1.1.6HaStatusTCread-onlycurrent
highAvailabilityComponent
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.22.3
highAvailabilityComponentTable
OBJECT-TYPE
This table provides high availability component information.
1.3.6.1.4.1.19746.1.22.3.1not-accessiblecurrent
highAvailabilityComponentEntry
OBJECT-TYPE
An entry represents one instance about a high availability component.
1.3.6.1.4.1.19746.1.22.3.1.1not-accessiblecurrent
highAvailabilityComponentIdx
OBJECT-TYPE
The index into this table indentifying a particular component.
1.3.6.1.4.1.19746.1.22.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
highAvailabilityComponentName
OBJECT-TYPE
The name of the component.
1.3.6.1.4.1.19746.1.22.3.1.1.2DDMibTableString128TCread-onlycurrent
highAvailabilityComponentState
OBJECT-TYPE
The status of the component.
1.3.6.1.4.1.19746.1.22.3.1.1.3HaStatusTCread-onlycurrent
scsitarget
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23
scsitargetProperties
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23.1
scsitargetAdminState
OBJECT-TYPE
Scsitarget Admin State
1.3.6.1.4.1.19746.1.23.1.1DDMibString96TCread-onlycurrent
scsitargetProcessState
OBJECT-TYPE
Scsitarget Process State
1.3.6.1.4.1.19746.1.23.1.2DDMibString96TCread-onlycurrent
scsitargetGroup
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23.2
scsitargetGroupTable
OBJECT-TYPE
Scsitarget Group Table
1.3.6.1.4.1.19746.1.23.2.1not-accessiblecurrent
scsitargetGroupEntry
OBJECT-TYPE
scsitargetGroupEntry
1.3.6.1.4.1.19746.1.23.2.1.1not-accessiblecurrent
scsitargetGroupIndex
OBJECT-TYPE
Scsitarget Group Index
1.3.6.1.4.1.19746.1.23.2.1.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetGroupName
OBJECT-TYPE
Scsitarget Group Name
1.3.6.1.4.1.19746.1.23.2.1.1.2DDMibTableString512TCread-onlycurrent
scsitargetGroupService
OBJECT-TYPE
Scsitarget Group Service
1.3.6.1.4.1.19746.1.23.2.1.1.3DDMibTableString512TCread-onlycurrent
scsitargetGroupActiveState
OBJECT-TYPE
Scsitarget Group Active State
1.3.6.1.4.1.19746.1.23.2.1.1.4DDMibString96TCread-onlycurrent
scsitargetGroupNumInitiators
OBJECT-TYPE
Scsitarget Group Number of Initiators
1.3.6.1.4.1.19746.1.23.2.1.1.5DDMibInteger32TCread-onlycurrent
scsitargetGroupNumDevices
OBJECT-TYPE
Scsitarget Group Number of Devices
1.3.6.1.4.1.19746.1.23.2.1.1.6DDMibInteger32TCread-onlycurrent
scsitargetInitiator
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23.3
scsitargetInitiatorTable
OBJECT-TYPE
Scsitarget Initiator Table
1.3.6.1.4.1.19746.1.23.3.1not-accessiblecurrent
scsitargetInitiatorEntry
OBJECT-TYPE
scsitargetInitiatorEntry
1.3.6.1.4.1.19746.1.23.3.1.1not-accessiblecurrent
scsitargetInitiatorIndex
OBJECT-TYPE
Scsitarget Initiator Index
1.3.6.1.4.1.19746.1.23.3.1.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetInitiatorName
OBJECT-TYPE
Scsitarget Initiator Name
1.3.6.1.4.1.19746.1.23.3.1.1.2DDMibTableString512TCread-onlycurrent
scsitargetInitiatorSystemAddress
OBJECT-TYPE
Scsitarget Initiator System Address
1.3.6.1.4.1.19746.1.23.3.1.1.3DDMibTableString512TCread-onlycurrent
scsitargetInitiatorGroup
OBJECT-TYPE
Scsitarget Initiator Group
1.3.6.1.4.1.19746.1.23.3.1.1.4DDMibTableString512TCread-onlycurrent
scsitargetInitiatorService
OBJECT-TYPE
Scsitarget Initiator Service
1.3.6.1.4.1.19746.1.23.3.1.1.5DDMibTableString512TCread-onlycurrent
scsitargetInitiatorAddressMethod
OBJECT-TYPE
Scsitarget Initiator Address Method
1.3.6.1.4.1.19746.1.23.3.1.1.6DDMibTableString512TCread-onlycurrent
scsitargetInitiatorTransport
OBJECT-TYPE
Scsitarget Initiator Transport
1.3.6.1.4.1.19746.1.23.3.1.1.7DDMibTableString512TCread-onlycurrent
scsitargetInitiatorFcWwpn
OBJECT-TYPE
Scsitarget Initiator Fc Wwpn
1.3.6.1.4.1.19746.1.23.3.1.1.8DDMibTableString512TCread-onlycurrent
scsitargetInitiatorFcWwnn
OBJECT-TYPE
Scsitarget Initiator Fc Wwnn
1.3.6.1.4.1.19746.1.23.3.1.1.9DDMibTableString512TCread-onlycurrent
scsitargetInitiatorFcSymbolicPortName
OBJECT-TYPE
Scsitarget Initiator Fc Symbolic Port Name
1.3.6.1.4.1.19746.1.23.3.1.1.10DDMibTableString512TCread-onlycurrent
scsitargetInitiatorEndpTable
OBJECT-TYPE
Scsitarget Initiator Endpoint Table
1.3.6.1.4.1.19746.1.23.3.2not-accessiblecurrent
scsitargetInitiatorEndpEntry
OBJECT-TYPE
scsitargetInitiatorEndpEntry
1.3.6.1.4.1.19746.1.23.3.2.1not-accessiblecurrent
scsitargetInitiatorEndpIndex
OBJECT-TYPE
Scsitarget Initiator Endpoint Index
1.3.6.1.4.1.19746.1.23.3.2.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetInitiatorEndpInitiator
OBJECT-TYPE
Scsitarget Initiator
1.3.6.1.4.1.19746.1.23.3.2.1.2DDMibTableString512TCread-onlycurrent
scsitargetInitiatorEndpEndpoint
OBJECT-TYPE
Scsitarget Initiator Endpoint
1.3.6.1.4.1.19746.1.23.3.2.1.3DDMibTableString512TCread-onlycurrent
scsitargetInitiatorEndpStatus
OBJECT-TYPE
Scsitarget Initiator Endpoint Status
1.3.6.1.4.1.19746.1.23.3.2.1.4DDMibString96TCread-onlycurrent
scsitargetEndpoint
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23.4
scsitargetEndpointTable
OBJECT-TYPE
Scsitarget Endpoint Table
1.3.6.1.4.1.19746.1.23.4.1not-accessiblecurrent
scsitargetEndpointEntry
OBJECT-TYPE
scsitargetEndpointEntry
1.3.6.1.4.1.19746.1.23.4.1.1not-accessiblecurrent
scsitargetEndpointIndex
OBJECT-TYPE
Scsitarget Endpoint Index
1.3.6.1.4.1.19746.1.23.4.1.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetEndpointName
OBJECT-TYPE
Scsitarget Endpoint Name
1.3.6.1.4.1.19746.1.23.4.1.1.2DDMibTableString512TCread-onlycurrent
scsitargetEndpointCurrentSystemAddress
OBJECT-TYPE
Scsitarget Endpoint Current System Address
1.3.6.1.4.1.19746.1.23.4.1.1.3DDMibTableString512TCread-onlycurrent
scsitargetEndpointPrimarySystemAddress
OBJECT-TYPE
Scsitarget Endpoint Primary System Address
1.3.6.1.4.1.19746.1.23.4.1.1.4DDMibTableString512TCread-onlycurrent
scsitargetEndpointSecondarySystemAddress
OBJECT-TYPE
Scsitarget Endpoint Secondary System Address
1.3.6.1.4.1.19746.1.23.4.1.1.5DDMibTableString512TCread-onlycurrent
scsitargetEndpointEnabled
OBJECT-TYPE
Scsitarget Endpoint Enabled
1.3.6.1.4.1.19746.1.23.4.1.1.6DDStatusTCread-onlycurrent
scsitargetEndpointStatus
OBJECT-TYPE
Scsitarget Endpoint Status
1.3.6.1.4.1.19746.1.23.4.1.1.7DDMibTableString512TCread-onlycurrent
scsitargetEndpointTransport
OBJECT-TYPE
Scsitarget Endpoint Transport
1.3.6.1.4.1.19746.1.23.4.1.1.8DDMibTableString512TCread-onlycurrent
scsitargetEndpointFcWwnn
OBJECT-TYPE
Scsitarget Endpoint Fc Wwnn
1.3.6.1.4.1.19746.1.23.4.1.1.9DDMibTableString512TCread-onlycurrent
scsitargetEndpointFcWwpn
OBJECT-TYPE
Scsitarget Endpoint Fc Wwpn
1.3.6.1.4.1.19746.1.23.4.1.1.10DDMibTableString512TCread-onlycurrent
scsitargetPort
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23.5
scsitargetPortTable
OBJECT-TYPE
Scsitarget Port Table
1.3.6.1.4.1.19746.1.23.5.1not-accessiblecurrent
scsitargetPortEntry
OBJECT-TYPE
scsitargetPortEntry
1.3.6.1.4.1.19746.1.23.5.1.1not-accessiblecurrent
scsitargetPortIndex
OBJECT-TYPE
Scsitarget Port Index
1.3.6.1.4.1.19746.1.23.5.1.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetPortSystemAddress
OBJECT-TYPE
Scsitarget Port System Address
1.3.6.1.4.1.19746.1.23.5.1.1.2DDMibTableString512TCread-onlycurrent
scsitargetPortEnabled
OBJECT-TYPE
Scsitarget Port Enabled
1.3.6.1.4.1.19746.1.23.5.1.1.3DDStatusTCread-onlycurrent
scsitargetPortStatus
OBJECT-TYPE
Scsitarget Port Status
1.3.6.1.4.1.19746.1.23.5.1.1.4DDMibTableString512TCread-onlycurrent
scsitargetPortTransport
OBJECT-TYPE
Scsitarget Port Transport
1.3.6.1.4.1.19746.1.23.5.1.1.5DDMibTableString512TCread-onlycurrent
scsitargetPortOperationalStatus
OBJECT-TYPE
Scsitarget Port Operational Status
1.3.6.1.4.1.19746.1.23.5.1.1.6DDMibTableString512TCread-onlycurrent
scsitargetPortFcNpiv
OBJECT-TYPE
Scsitarget Port Fc Npiv
1.3.6.1.4.1.19746.1.23.5.1.1.7DDMibTableString512TCread-onlycurrent
scsitargetPortPortId
OBJECT-TYPE
Scsitarget Port Port Id
1.3.6.1.4.1.19746.1.23.5.1.1.8DDMibTableString512TCread-onlycurrent
scsitargetPortModel
OBJECT-TYPE
Scsitarget Port Model
1.3.6.1.4.1.19746.1.23.5.1.1.9DDMibTableString512TCread-onlycurrent
scsitargetPortFirmware
OBJECT-TYPE
Scsitarget Port Firmware
1.3.6.1.4.1.19746.1.23.5.1.1.10DDMibTableString512TCread-onlycurrent
scsitargetPortFcBaseWwnn
OBJECT-TYPE
Scsitarget Port Fc Base Wwnn
1.3.6.1.4.1.19746.1.23.5.1.1.11DDMibTableString512TCread-onlycurrent
scsitargetPortFcBaseWwpn
OBJECT-TYPE
Scsitarget Port Fc Base Wwpn
1.3.6.1.4.1.19746.1.23.5.1.1.12DDMibTableString512TCread-onlycurrent
scsitargetPortFcCurrentWwnn
OBJECT-TYPE
Scsitarget Port Fc Current Wwnn
1.3.6.1.4.1.19746.1.23.5.1.1.13DDMibTableString512TCread-onlycurrent
scsitargetPortFcCurrentWwpn
OBJECT-TYPE
Scsitarget Port Fc Current Wwpn
1.3.6.1.4.1.19746.1.23.5.1.1.14DDMibTableString512TCread-onlycurrent
scsitargetPortFcp2Retry
OBJECT-TYPE
Scsitarget Port Fcp2 Retry
1.3.6.1.4.1.19746.1.23.5.1.1.15DDMibTableString512TCread-onlycurrent
scsitargetPortConnectionType
OBJECT-TYPE
scsitarget Port Connection Type
1.3.6.1.4.1.19746.1.23.5.1.1.16DDMibTableString512TCread-onlycurrent
scsitargetPortLinkSpeed
OBJECT-TYPE
Scsitarget Port Link Speed
1.3.6.1.4.1.19746.1.23.5.1.1.17DDMibTableString512TCread-onlycurrent
scsitargetPortFcTopology
OBJECT-TYPE
Scsitarget Port Fc Topology
1.3.6.1.4.1.19746.1.23.5.1.1.18DDMibTableString512TCread-onlycurrent
scsitargetPortEndpTable
OBJECT-TYPE
Scsitarget Port Endpoint Table
1.3.6.1.4.1.19746.1.23.5.2not-accessiblecurrent
scsitargetPortEndpEntry
OBJECT-TYPE
scsitargetPortEndpEntry
1.3.6.1.4.1.19746.1.23.5.2.1not-accessiblecurrent
scsitargetPortEndpIndex
OBJECT-TYPE
Scsitarget Port Endpoint Index
1.3.6.1.4.1.19746.1.23.5.2.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetPortEndpPort
OBJECT-TYPE
Scsitarget Port
1.3.6.1.4.1.19746.1.23.5.2.1.2DDMibTableString512TCread-onlycurrent
scsitargetPortEndpEndpoint
OBJECT-TYPE
Scsitarget Port Endpoint
1.3.6.1.4.1.19746.1.23.5.2.1.3DDMibTableString512TCread-onlycurrent
scsitargetPortEndpEnabled
OBJECT-TYPE
Scsitarget Port Endpoint Enabled
1.3.6.1.4.1.19746.1.23.5.2.1.4DDStatusTCread-onlycurrent
scsitargetPortEndpStatus
OBJECT-TYPE
Scsitarget Port Endpoint Status
1.3.6.1.4.1.19746.1.23.5.2.1.5DDMibString96TCread-onlycurrent
scsitargetPortEndpCurrentInstance
OBJECT-TYPE
Scsitarget Port Endpoint Current Instance
1.3.6.1.4.1.19746.1.23.5.2.1.6DDMibTableString512TCread-onlycurrent
scsitargetDevice
OBJECT-IDENTITY
1.3.6.1.4.1.19746.1.23.6
scsitargetDeviceTable
OBJECT-TYPE
Scsitarget Device Table
1.3.6.1.4.1.19746.1.23.6.1not-accessiblecurrent
scsitargetDeviceEntry
OBJECT-TYPE
scsitargetDeviceEntry
1.3.6.1.4.1.19746.1.23.6.1.1not-accessiblecurrent
scsitargetDeviceIndex
OBJECT-TYPE
Scsitarget Device Index
1.3.6.1.4.1.19746.1.23.6.1.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetDeviceName
OBJECT-TYPE
Scsitarget Device Name
1.3.6.1.4.1.19746.1.23.6.1.1.2DDMibTableString512TCread-onlycurrent
scsitargetDeviceService
OBJECT-TYPE
Scsitarget Device Service
1.3.6.1.4.1.19746.1.23.6.1.1.3DDMibTableString512TCread-onlycurrent
scsitargetDeviceActiveState
OBJECT-TYPE
Scsitarget Device Active State
1.3.6.1.4.1.19746.1.23.6.1.1.4DDMibString96TCread-onlycurrent
scsitargetDeviceAddress
OBJECT-TYPE
Scsitarget Device Address
1.3.6.1.4.1.19746.1.23.6.1.1.5DDMibTableString512TCread-onlycurrent
scsitargetDeviceGrpTable
OBJECT-TYPE
Scsitarget Device Group Table
1.3.6.1.4.1.19746.1.23.6.2not-accessiblecurrent
scsitargetDeviceGrpEntry
OBJECT-TYPE
scsitargetDeviceGrpEntry
1.3.6.1.4.1.19746.1.23.6.2.1not-accessiblecurrent
scsitargetDeviceGrpIndex
OBJECT-TYPE
Scsitarget Device Group Index
1.3.6.1.4.1.19746.1.23.6.2.1.1DDMibTableIndexTCnot-accessiblecurrent
scsitargetDeviceGrpDevice
OBJECT-TYPE
Scsitarget Device
1.3.6.1.4.1.19746.1.23.6.2.1.2DDMibTableString512TCread-onlycurrent
scsitargetDeviceGrpGroupName
OBJECT-TYPE
Scsitarget Device Group Name
1.3.6.1.4.1.19746.1.23.6.2.1.3DDMibTableString512TCread-onlycurrent
scsitargetDeviceGrpLun
OBJECT-TYPE
Scsitarget Device Group Lun
1.3.6.1.4.1.19746.1.23.6.2.1.4DDMibTableString512TCread-onlycurrent
scsitargetDeviceGrpPrimaryEndpoints
OBJECT-TYPE
Scsitarget Device Group Primary Endpoints
1.3.6.1.4.1.19746.1.23.6.2.1.5DDMibTableString512TCread-onlycurrent
scsitargetDeviceGrpSecondaryEndpoints
OBJECT-TYPE
Scsitarget Device Group Secondary Endpoints
1.3.6.1.4.1.19746.1.23.6.2.1.6DDMibTableString512TCread-onlycurrent
scsitargetDeviceGrpInUseEndpoints
OBJECT-TYPE
Scsitarget Device Group In Use Endpoints
1.3.6.1.4.1.19746.1.23.6.2.1.7DDMibTableString512TCread-onlycurrent
dataDomainMibNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.19746.2
dataDomainMibTraps
OBJECT-IDENTITY
1.3.6.1.4.1.19746.2.0
dataDomainMibProducts
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3
restorer
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1
unknown
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.0
dd200
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.1
dd200Proto
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.2
dd410
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.3
dd430
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.4
dd460
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.5
dd400g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.6
dd460g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.7
dd560
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.8
dd560g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.9
dd580
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.10
dd580g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.11
dd565
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.12
dd530
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.13
dd510
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.14
dd120
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.15
dd690
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.16
dd690g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.17
dd660
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.18
dd880
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.19
dd880g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.20
dd610
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.21
dd630
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.22
dd140
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.23
dd670
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.24
dd860
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.25
dd860g
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.26
dd890
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.27
dd640
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.28
dd620
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.29
dd160
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.30
ddintrepid
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.31
dd4500
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.32
dd7200
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.33
ddve
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.34
dd990
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.35
dd2500
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.36
dd4200
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.37
ddkoalam1
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.38
apollo
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.39
unset
OBJECT-IDENTITY
1.3.6.1.4.1.19746.3.1.9999

Notifications

NameOIDStatus
powerSupplyFailedAlarm
NOTIFICATION-TYPE
Meaning: Power Supply failed What to do: replace the power supply
1.3.6.1.4.1.19746.2.0.1deprecated
systemOverheatWarningAlarm
NOTIFICATION-TYPE
Meaning: the temperature reading of one of the thermometers in the Chassis has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.
1.3.6.1.4.1.19746.2.0.2deprecated
systemOverheatAlertAlarm
NOTIFICATION-TYPE
Meaning: the temperature reading of one of the thermometers in the Chassis is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the system temperature.
1.3.6.1.4.1.19746.2.0.3deprecated
systemOverheatShutdownAlarm
NOTIFICATION-TYPE
Meaning: the temperature reading of one of the thermometers in the Chassis has reached or exceeded the 'shutdown' temperature level. The DDR will be shutdown to prevent damage to the system. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: Once the system has been brought back up, after checking for high environment temperatures or other factors which may increase the system temperature, check other environmental values, such as Fan Status, Disk Temperatures, etc...
1.3.6.1.4.1.19746.2.0.4deprecated
fanModuleFailedAlarm
NOTIFICATION-TYPE
Meaning: a Fan Module in the enclosure has failed. The index of the fan is given as the index of the alarm. This same index can be looked up in the environmentals table 'fanProperies' for more information about which fan has failed. What to do: replace the fan
1.3.6.1.4.1.19746.2.0.5deprecated
nvramFailingAlarm
NOTIFICATION-TYPE
Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue.
1.3.6.1.4.1.19746.2.0.6deprecated
fileSystemFailedAlarm
NOTIFICATION-TYPE
Meaning: The File System process on the DDR has had a serious problem and has had to restart. What to do: check the system logs for conditions that may be triggering the failure. Other alarms may also indicate why the File System is having problems.
1.3.6.1.4.1.19746.2.0.7deprecated
fileSpaceMaintenanceAlarm
NOTIFICATION-TYPE
Meaning: DDVAR File System Resource Space is running low for system maintenance activities. The system may not have enough space for the routine system activities to run without error. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system.
1.3.6.1.4.1.19746.2.0.8deprecated
fileSpacePreWarningAlarm
NOTIFICATION-TYPE
Meaning: A File System Resource space is 80-85% utilized. While not critical, the space usage should be monitored. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: no action is necessary, but the file system should be monitored more closely as it grows more full. Further alarms will be sent when and if the file system space is approaching very full.
1.3.6.1.4.1.19746.2.0.9deprecated
fileSpaceWarningAlarm
NOTIFICATION-TYPE
Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
1.3.6.1.4.1.19746.2.0.10deprecated
fileSpaceSevereAlarm
NOTIFICATION-TYPE
Meaning: A File System Resource space is 95% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
1.3.6.1.4.1.19746.2.0.11deprecated
fileSpaceCriticalAlarm
NOTIFICATION-TYPE
Meaning: A File System Resource space is 100% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
1.3.6.1.4.1.19746.2.0.12deprecated
diskFailedAlarm
NOTIFICATION-TYPE
Meaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk that has failed. What to do: replace the disk.
1.3.6.1.4.1.19746.2.0.14deprecated
diskOverheatWarningAlarm
NOTIFICATION-TYPE
Meaning: the temperature reading of the indicated disk has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.
1.3.6.1.4.1.19746.2.0.15deprecated
diskOverheatAlertAlarm
NOTIFICATION-TYPE
Meaning: the temperature reading of the indicated disk is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it will trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature. If the temperature continues stays at this level or rises, and no other disks are reading this trouble, consider 'failing' the disk, and get a replacement.
1.3.6.1.4.1.19746.2.0.16deprecated
diskOverheatShutdownAlarm
NOTIFICATION-TYPE
Meaning: the temperature reading of the indicated disk has surpassed the 'shutdown' temperature level. The DDR will be shutdown. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: Boot the DDR and monitor the status and temperatures. If the same disk has continued problems, consider 'failing' it and get a replacement disk.
1.3.6.1.4.1.19746.2.0.17deprecated
raidReconSevereAlarm
NOTIFICATION-TYPE
Meaning: A raid group is MAX degraded with no reconstruction after less than 71 hours or A disk group is degraded with none max degraded with no reconstruction. This alarm is sent every 1 hour until 71 hours after which raidReconCriticalAlarm or raidReconCriticalShutdown alarm is generated. This can happen due to a disk failing at run-time or boot-time. What to do: while it is still possible that the reconstruction could succeed, the disk should be replaced to ensure data safety.
1.3.6.1.4.1.19746.2.0.18deprecated
raidReconCriticalAlarm
NOTIFICATION-TYPE
Meaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can happen due to a disk failing at run-time or boot-up. What to do: the disk should be replaced to ensure data safety.
1.3.6.1.4.1.19746.2.0.19deprecated
raidReconCriticalShutdownAlarm
NOTIFICATION-TYPE
Meaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can happen due to a disk failing at run-time or boot-up. What to do: the disk must be replaced.
1.3.6.1.4.1.19746.2.0.20deprecated
raidGroupMissingAlarm
NOTIFICATION-TYPE
Meaning: one or more raid groups are missing. What to do: disk may need replacement, or raid administration may be necessary.
1.3.6.1.4.1.19746.2.0.21deprecated
diskNoSpareAlarm
NOTIFICATION-TYPE
Meaning: there is no spare available for the raid group. What to do: disk may need replacement, or raid administration may be necessary.
1.3.6.1.4.1.19746.2.0.22deprecated
diskPathAlarm
NOTIFICATION-TYPE
Meaning: multipath configuration is experiencing a problem. The number of paths set up is less than the required number of paths. Disk index is the first disk in the enclosure with multipath. What to do: multipath disk administration may be necessary.
1.3.6.1.4.1.19746.2.0.23deprecated
diskSASAlarm
NOTIFICATION-TYPE
Meaning: SAS configuration error. Maximum enclosures has been reached, or there is a topology problem. What to do: SAS configuration documentation should be consulted. administration may be necessary.
1.3.6.1.4.1.19746.2.0.24deprecated
diskSASHBAAlarm
NOTIFICATION-TYPE
Meaning: Unsupported multi-path setting is enabled in the hba firmware. What to do: contact Data Domain support.
1.3.6.1.4.1.19746.2.0.25deprecated
snapshotFullAlarm
NOTIFICATION-TYPE
Meaning: maximum number of snapshots has been reached. What to do: expire some old snapshots to make room.
1.3.6.1.4.1.19746.2.0.26deprecated
snapshotHWMAlarm
NOTIFICATION-TYPE
Meaning: the number of snapshots has exceeded a predefined percentage (current 90%) of the maximum. What to do: begin expiring snapshots so that the maximum is not reached.
1.3.6.1.4.1.19746.2.0.27deprecated
clusterNodeAlarm
NOTIFICATION-TYPE
Meaning: node is not reachable on any network interface. What to do: check status of network and wiring. if that fails, try rebooting the node.
1.3.6.1.4.1.19746.2.0.28deprecated
clusterInterfaceAlarm
NOTIFICATION-TYPE
Meaning: one interface of the cluster node is down. What to do: check status of network and wiring. if that fails, try rebooting the node.
1.3.6.1.4.1.19746.2.0.29deprecated
replSyncAlarm
NOTIFICATION-TYPE
Meaning: a replication context is disabled due to nvram loss. What to do: break replication on source and destination, then reconfigure them and run replication sync.
1.3.6.1.4.1.19746.2.0.30deprecated
systemStartupAlarm
NOTIFICATION-TYPE
Meaning: system has rebooted or started. this does not indicate any abnormal activity. What to do: nothing, unless reboot was triggered by other abnormal conditions, such as temperature, fan or power problems.
1.3.6.1.4.1.19746.2.0.31deprecated
filesysRelaunchAlarm
NOTIFICATION-TYPE
Meaning: file system has undergone too many relaunches. it is probably unstable. What to do: consult system logs. software or hardware restart may fix the malfunction.
1.3.6.1.4.1.19746.2.0.32deprecated
filesysDDGCFailedAlarm
NOTIFICATION-TYPE
Meaning: DDGC cleaning process has failed. What to do: consult system logs. software or hardware restart may fix the malfunction.
1.3.6.1.4.1.19746.2.0.33deprecated
filesysGeneralProblemAlarm
NOTIFICATION-TYPE
Meaning: a general problem has occurred with the file system. What to do: consult system logs. software or hardware restart may fix the malfunction.
1.3.6.1.4.1.19746.2.0.34deprecated
diskUnsupportedAlarm
NOTIFICATION-TYPE
Meaning: the model of the disk is unsupported by current DD platform. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk. What to do: replace the disk.
1.3.6.1.4.1.19746.2.0.35deprecated
eventIPMIUnmanageAlarm
NOTIFICATION-TYPE
Meaning: IPMI unmanaged alert detected. What to do: check alert message
1.3.6.1.4.1.19746.2.0.36deprecated
controllerUnreachableAlert
NOTIFICATION-TYPE
Description: This is a GDA event raised by the Master controller when it fails to reach a Worker controller for more than 5 minutes. An unreachable Worker controller implies none of the Worker controller interfaces are pingable from the Master controller. Action: Check the status of network interfaces on both controllers. Check network connectivity between the Master and Worker controller. Make sure all cables are securely connected.
1.3.6.1.4.1.19746.2.0.5002current
controllerIfaceUnreachableAlert
NOTIFICATION-TYPE
Description: This is a GDA event raised by the Master controller when it fails to reach a particular Worker controller interface for more than 5 minutes. An unreachable interface implies that it is not pingable from its Master controller equivalent interface. Action: Check network interface status on both controllers. Check network connectivity between the Master and Worker controller. Make sure all cables are securely connected.
1.3.6.1.4.1.19746.2.0.5003current
correctableECCLimitReached
NOTIFICATION-TYPE
Description: Single bit correctable ECC limit reached. Action: Replace the failed DIMM(s). Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5004current
uncorrectableECCerror
NOTIFICATION-TYPE
Description: Multi bit uncorrectable ECC error. Action: Replace the failed DIMM(s). Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5005current
legacyChassisTempWarning
NOTIFICATION-TYPE
Description: Current temperature sensor reading exceeds warning threshold. Action: Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5006current
legacyChassisTempCritical
NOTIFICATION-TYPE
Description: Current temperature sensor reading exceeds critical threshold. Action: Check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5007current
legacyPowerSupplyWarning
NOTIFICATION-TYPE
Description: A power supply has failed, is unplugged, or absent. Action: Check power supply cables and LED. Replace with other working power supply. If there are outstanding alerts for all power supplies in an enclosure, the system must be shutdown before replacing any power supply. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5008current
legacyFanWarning
NOTIFICATION-TYPE
Description: A fan has failed. Action: Check for any failed fan. If failed, replace with new fan. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5009current
powerSupplyWarning
NOTIFICATION-TYPE
Description: A power supply has failed, is unplugged, or absent. Action: Check power supply cables and LED. Replace with other working power supply. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5010current
fanWarning
NOTIFICATION-TYPE
Description: A fan has failed or is missing. Action: Check for any failed or missing fan. Reseat the fan. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5011current
voltageWarning
NOTIFICATION-TYPE
Description: Voltage sensor reading exceeds warning threshold. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5012current
powerWarning
NOTIFICATION-TYPE
Description: Current power consumption reading exceeds warning threshold. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5013current
correctECCWarning
NOTIFICATION-TYPE
Description: Memory correctable ECC errors exceed warning threshold. Action: These memory errors are automatically corrected by the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5014current
processorWarning
NOTIFICATION-TYPE
Description: Processor status sensor alert. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5016current
powerUnitWarning
NOTIFICATION-TYPE
Description: This event is expected after power off, power cycle, or AC power loss event. Action: If this alert is not expected, check power cords and AC power. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5017current
unCorrectECCWarning
NOTIFICATION-TYPE
Description: Memory uncorrectable ECC error alert. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5018current
chassisSensorCritical
NOTIFICATION-TYPE
Description: Current sensor reading or state exceeds critical condition. Action: Check the specific alert message for information. Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5020current
chassisTempWarning
NOTIFICATION-TYPE
Description: Current temperature sensor reading exceeds warning threshold. Action: Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5021current
chassisTempCritical
NOTIFICATION-TYPE
Description: Current temperature sensor reading exceeds critical threshold. Action: Check ambient room temperature and for blocked air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5022current
cPUFailureWarning
NOTIFICATION-TYPE
Description: DDOS has detected a fault with the indicated CPU. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5023current
legacyBMCHangCritical
NOTIFICATION-TYPE
Description: While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating. Action: Use CLI or Enterprise Manager to check fan, voltage, and power supply readings. If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC. Wait until all LEDS are off. Reinsert the power cables and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5024current
bMCHangCritical
NOTIFICATION-TYPE
Description: While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating. Action: Use CLI or Enterprise Manager to check fan, voltage, and power supply readings. If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC. Wait until all LEDS are off. Reinsert the power cables and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5025current
abnormalShutdown
NOTIFICATION-TYPE
Description: The system has been shutdown by abnormal method, i.e. not by one of the following: 1) Via IPMI chassis control command 2) Via power button 3) Via OS shutdown Action: This alert is expected after loss of AC (main power) event. If this shutdown is not expected and persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5026current
tooManyRelaunches
NOTIFICATION-TYPE
Description: The filesystem has failed to restart after multiple attempts. Backup and restore services are unavailable. Action: Contact your contracted support provider or visit us online at https://support.emc.com to diagnose the failure.
1.3.6.1.4.1.19746.2.0.5027current
filesystemProblem
NOTIFICATION-TYPE
Description: A problem is preventing the filesystem from running. This usually involves the storage being unavailable. Action: Check disk shelf cabling. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5028current
dDFSFailedInShutdown
NOTIFICATION-TYPE
Description: The filesystem shut down encountered an error. This can potentially leave data in the NVRAM which would be normally flushed to the disk. Failed shutdown can leave the filesystem in a state that can prevent certain operations from being performed (i.e. system upgrade, filesys destroy, etc.) and may cause data loss. Action: Re-enable the filesystem and try shutting it down again. If the problem persists, Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5030current
dDFSNoHeartbeat
NOTIFICATION-TYPE
Description: Filesystem has encountered an error and is forced to restart. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5034current
dDFSDiedAfterReboot
NOTIFICATION-TYPE
Description: The filesystem failed to startup immediately after system reboot. Action: Contact your contracted support provider or visit us online at https://support.emc.com for diagnosis of the cause of failure. No other action required if filesystem successfully restarts.
1.3.6.1.4.1.19746.2.0.5036current
dDFSDied
NOTIFICATION-TYPE
Description: The filesystem process failed and is restarting. Action: Contact your contracted support provider or visit us online at https://support.emc.com for diagnosis of the cause of failure. No other action required if filesystem successfully restarts.
1.3.6.1.4.1.19746.2.0.5037current
dDFSRebooted
NOTIFICATION-TYPE
Description: This is just a notification alert that the system has been rebooted. Action: No action required.
1.3.6.1.4.1.19746.2.0.5038current
dDFSRebootedDisabled
NOTIFICATION-TYPE
Description: This is a notification alert sent out during system startup following a reboot. The system is rebooted with the filesystem in disabled state. Action: No action is required unless the intent is to have the filesystem enabled. In that case, invoke the 'filesys enable' command.
1.3.6.1.4.1.19746.2.0.5039current
indexRebuildComplete
NOTIFICATION-TYPE
Description: The metadata rebuild operation that was started by support has completed. The system is ready for the next action. Action: Contact your contracted support provider or visit us online at https://support.emc.com to perform the next operation on your system.
1.3.6.1.4.1.19746.2.0.5040current
historicalDatabaseRecoverError
NOTIFICATION-TYPE
Description: All existing historical data has been lost. Data in the historical database is used for some system reports, but it is not required for proper system functioning. This failure may occur during head swap processing if recovery to create the new head primary historical database from the shelf database files fails or historical database may be corrupted. Action: Contact your contracted support provider or visit us online at https://support.emc.com to debug this problem and possibly attempt recovery of the lost historical data.
1.3.6.1.4.1.19746.2.0.5041current
historicalDatabaseBackupError
NOTIFICATION-TYPE
Description: Historical database backup failed. If the primary historical database fails without a recent backup present, some or all of the historical data can be lost when the primary historical database is restored from its backup and log files. Data in the historical database is used for some system reports, but it is not required for proper system functioning. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem.
1.3.6.1.4.1.19746.2.0.5042current
historicalDatabaseUpgradeError
NOTIFICATION-TYPE
Description: Historical database upgrade failed during software upgrade. New historical data fields will not be saved. Some UI reports might be unavailable, or be missing data. Otherwise, this should not affect the system. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem and upgrade the historical database.
1.3.6.1.4.1.19746.2.0.5043current
historicalDatabasePruneError
NOTIFICATION-TYPE
Description: Historical database pruning failed. Pruning ensures the historical database does not consume more than its allocated disk space. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem.
1.3.6.1.4.1.19746.2.0.5044current
noHistoricalDatabaseError
NOTIFICATION-TYPE
Description: Data in the historical database is used for some system reports, but it is not required for proper system functioning. This failure may occur during head swap processing if recovery to create the new head primary historical database from the shelf database files fails or the database has been corrupted. The system is running without historical database after failing to create a new one. Action: Contact your contracted support provider or visit us online at https://support.emc.com to debug this problem and possibly attempt recovery of the lost historical data.
1.3.6.1.4.1.19746.2.0.5045current
hDTFileTransferFailed
NOTIFICATION-TYPE
Description: Unable to send historical data update file to Data Domain Management Center. Action: Check DNS settings and network connection between the Data Domain System and Data Domain Management Center. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5046current
hDTSystemError
NOTIFICATION-TYPE
Description: System Error occurred while sending historical data to Data Domain Management Center. Action: Check configuration and system status, messages logs for indicative problems. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5047current
dIMMFailureAlert
NOTIFICATION-TYPE
Description: DIMM failure detected. DDFS can't be enabled. Action: Replace the bad DIMMS.
1.3.6.1.4.1.19746.2.0.5048current
memoryAlert
NOTIFICATION-TYPE
Description: Current memory is less than configured. DDFS can't be enabled. Action: Check the DIMMS in DDR. Add new DIMMS and/or replace the bad DIMMS.
1.3.6.1.4.1.19746.2.0.5049current
portPathDisabled
NOTIFICATION-TYPE
Description: A path is disabled. Multipath failover will not work correctly until the port is enabled. Action: Verify all storage cabling is connected correctly. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5050current
diskPathRedundancy
NOTIFICATION-TYPE
Description: Since only one HBA controller has been detected, disk path redundancy is lost. Action: If the HBA configuration is correct, disable multipath configuration. Otherwise: 1)Use 'disk multipath status' to examine connection status; 2)Verify all storage cabling is connected correctly; 3)Use 'enclosure' commands to verify that HBA controllers are functional. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5051current
missingPortConnection
NOTIFICATION-TYPE
Description: A port and the attached storage have disappeared. Action: Verify the connection and any external storage connected to the missing port.
1.3.6.1.4.1.19746.2.0.5052current
missingLunPath
NOTIFICATION-TYPE
Description: The number of active paths to a LUN has changed. Action: If this is due to reconfiguration, verify the topology and disable then re-enable multipath monitoring to reset the monitoring. If not, verify the storage cabling and that all paths are connected.
1.3.6.1.4.1.19746.2.0.5053current
missingDiskPath
NOTIFICATION-TYPE
Description: The number of active paths to a disk has decreased. Multipath redundancy has been lost unless there are more than one connection paths. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5054current
missingEnclosurePath
NOTIFICATION-TYPE
Description: The number of active paths to a disk has decreased. Multipath redundancy has been lost unless there are more than one connection paths. Action: Use 'enclosure' commands to verify that HBAs are functional. If this condition is due to configuration change: verify the topology, and then disable and re-enable disk multipath monitoring to reset connection counts. If not, verify the storage cabling is connected correctly. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5055current
nvramWarning
NOTIFICATION-TYPE
Description: DDFS is disabled due to a problem with the NVRAM subsystem. Action: Check for other NVRAM-related alerts and follow the action described in those alerts.
1.3.6.1.4.1.19746.2.0.5059current
nvramBatteryAlert
NOTIFICATION-TYPE
Description: DD OS detected an NVRAM card Battery Unit hardware fault. Probable causes: 1) Battery charging is disabled, or 2) One or more batteries are not charging. Action: Run CLI command 'system show nvram' to check battery status. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5060current
nvramErrorAlert
NOTIFICATION-TYPE
Description: DD OS detected an NVRAM card fault. Probable cause: Excessive correctable errors exceed the warning threshold number. Action: The NVRAM card may need to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5061current
phyalert
NOTIFICATION-TYPE
Description: Enclosure slot has been disabled due to continuous discovery caused by a failed drive. Action: Replace the failed drive. Use 'disk rescan' command specifying the disk and enclosure id to re-enable the slot.
1.3.6.1.4.1.19746.2.0.5062current
replProgressThreshholdReached
NOTIFICATION-TYPE
Description: Collection replication has not made progress and there is data waiting to be replicated. This means your replica is not up to date. Action: - check the 'replication status' or the GUI for errors - check the replica filesystem - check the network - if problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5063current
replNeedResync
NOTIFICATION-TYPE
Description: Replication will not proceed until this context is resynced. Action: To re-establish replication - Note the context information - break the context - reconfigure contexts on both source and destination - resync context on the source
1.3.6.1.4.1.19746.2.0.5064current
replLogFull
NOTIFICATION-TYPE
Description: No data can be written to the filesystem. Too much data remains to be replicated. This can be caused by disabled contexts or slow replication. When the condition is resolved, the filesystem will be writable again. Action: Refer to knowledge base for articles discussing ways to reduce replication lag.
1.3.6.1.4.1.19746.2.0.5065current
replIncompatibleWorm
NOTIFICATION-TYPE
Description: New retention-locked files detected on destination during replication resync. Resync cannot proceed. Action: Break the existing context and resync to a new destination.
1.3.6.1.4.1.19746.2.0.5066current
replDestNotConfigured
NOTIFICATION-TYPE
Description: Replication context on the destination is missing or mis-matched. Cannot initialize context. Action: - Check both the source and destination configured context URL pair. The context is identified by the destination URL. - Make sure the destination has a matching configuration for this context.
1.3.6.1.4.1.19746.2.0.5067current
replLagThreshholdReached
NOTIFICATION-TYPE
Description: Replication lag threshold has been exceeded. Action: Refer to the knowledge base on ways to resolve the replication lag.
1.3.6.1.4.1.19746.2.0.5068current
sASEnclosureCheck
NOTIFICATION-TYPE
Description: The number of enclosures connected to the port has exceeded the maximum supported limit. This may cause an unexpected behavior. Action: Reduce the number of enclosures down to the limit for the system.
1.3.6.1.4.1.19746.2.0.5069current
sASTopologyCheck
NOTIFICATION-TYPE
Description: Invalid cabling has been detected. This may cause unexpected behavior. Action: Refer to the cabling guide. Verify the connectivity of the SAS enclosures by using command 'enclosure show topology'.
1.3.6.1.4.1.19746.2.0.5070current
sASPortDisabled
NOTIFICATION-TYPE
Description: Excessive errors have caused this port to be disabled. This could be caused by faulty cables or shelf controllers. Action: Contact your contracted support provider or visit us online at https://support.emc.com .
1.3.6.1.4.1.19746.2.0.5071current
sSLCertificateCorrupted
NOTIFICATION-TYPE
Description: The SSL certificate used to establish mutual trust between Data Domain systems is broken. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.5072current
snapshotOver90Percent
NOTIFICATION-TYPE
Description: Current number of snapshots for an Mtree is at 90% or more of the maximum number of snapshots allowed. Action: Consider expiring existing snapshots of that Mtree with the 'snapshot expire' command or adjusting scheduled snapshot retention periods with the 'snapshot schedule modify' command.
1.3.6.1.4.1.19746.2.0.5075current
snapshotLimitReached
NOTIFICATION-TYPE
Description: Data Domain system has a limit on the number of existing snapshots held at once for a single Mtree. Once this limit is reached no more snapshots can be created of that Mtree. Action: Consider expiring existing snapshots of that Mtree with 'snapshot expire' command to make room for newer ones.
1.3.6.1.4.1.19746.2.0.5076current
sNTZMultipleIterations
NOTIFICATION-TYPE
Description: Indicates that sanitization will be run in multiple iterations. In the worst case this can take 15-20 days for 280 TBs. It means that the system will not run at full speed for that period of time and that GC will not be run to reclaim space. However, sanitization will also reclaim space back but it might not be as efficient as GC is. Action: Make sure that you have enough space to not run out of space and that you can wait that many days in the worst case. You should have at least 20% of physical space available. Other option is to abort sanitization, delete a bunch of files and try again. You can do this process iteratively until you do not get this alert anymore.
1.3.6.1.4.1.19746.2.0.5077current
coredumpWarning
NOTIFICATION-TYPE
Description: /ddvar might soon run out of space to save system core dumps. Action: Remove unwanted files from /ddvar to free up some space. Lack of space can result in missing core dumps that will hamper debugging operations.
1.3.6.1.4.1.19746.2.0.5078current
coredumpDisabled
NOTIFICATION-TYPE
Description: Space in /ddvar is not sufficient enough for saving system core dumps. Action: Remove unwanted files from /ddvar to free up some space. Lack of space can result in missing core dumps that will hamper debugging operations.
1.3.6.1.4.1.19746.2.0.5079current
spaceOver80Percent
NOTIFICATION-TYPE
Description: Space usage has exceeded 80% of the total capacity. Lack of space can result in missing important logs or loss of file system functionality. Action: If it is in root, contact your contracted support provider or visit us online at https://support.emc.com to free up some space. If it is in /ddvar, remove unwanted files to free up some space. If it is in active tier, remove unwanted files and start file system cleaning or add storage. If it is in archive tier, remove unwanted files or add more archive units to the filesystem.
1.3.6.1.4.1.19746.2.0.5080current
spaceOver90Percent
NOTIFICATION-TYPE
Description: Space usage has exceeded 90% of the total capacity. Lack of space can result in missing important logs or loss of file system functionality. Action: If it is in root, contact your contracted support provider or visit us online at https://support.emc.com to free up some space. If it is in /ddvar, remove unwanted files to free up some space. If it is in active tier, remove unwanted files and start file system cleaning or add storage. If it is in archive tier, remove unwanted files or add more archive units to the filesystem.
1.3.6.1.4.1.19746.2.0.5081current
diskAccessError
NOTIFICATION-TYPE
Description: A hardware fault has been detected for this drive. The drive or the cabling to it may have a problem. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5082current
diskFailure
NOTIFICATION-TYPE
Description: Unable to communicate with a disk. This disk cannot be used at this time. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5083current
diskTemperatureWarning
NOTIFICATION-TYPE
Description: The disk temperature has exceeded a specified threshold. If the temperature continues to increase, the system could fail or the system could be shut down. Action: If the temperature is high due to high activity for a short period, it should return to normal in a short time. Verify the environment is at its normal temperature. If not, correct this condition. Check for fan failures and free air flow. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5084current
diskTemperatureShutdown
NOTIFICATION-TYPE
Description: One or more disks have exceeded the shut down temperature threshold. The system is shutting down. Action: Verify the environment is at its normal temperature. If not, correct this condition. Check for fan failures and free air flow.
1.3.6.1.4.1.19746.2.0.5085current
unsupportedHardwareSpareSize
NOTIFICATION-TYPE
Description: The disk capacity is too small for it to be of any use in the system. Action: Replace with a larger capacity disk.
1.3.6.1.4.1.19746.2.0.5086current
missingDiskGroup
NOTIFICATION-TYPE
Description: One or more critical disks/LUNs are unavailable. Action: Make sure all storage is securely connected. Look at alert history for any path failures. Check for any core files, a critical layer may be unavailable. Verify that all storage is working and recognized correctly.
1.3.6.1.4.1.19746.2.0.5087current
diskGroupReconstructionNoProgress
NOTIFICATION-TYPE
Description: One or more disks are failed and the RAID reconstruction is not running. Action: Make sure there is/are spare disk(s) in the system.
1.3.6.1.4.1.19746.2.0.5088current
diskGroupReconstruction
NOTIFICATION-TYPE
Description: Two or more disks are failed and the RAID protection is in critical state. If an additional disk fails, there might be permanent loss of data. The system will shut down if the problem is not fixed. Action: Make sure there is/are spare disk(s) in the system.
1.3.6.1.4.1.19746.2.0.5089current
diskGroupReconstructionShutdown
NOTIFICATION-TYPE
Description: Two or more disks are failed and the RAID protection is in critical state for over a considerable period of time. If an additional disk fails, there might be permanent loss of data. The system will shut down. Action: Restart the system and make sure there is/are spare disk(s) in the system.
1.3.6.1.4.1.19746.2.0.5090current
diskGroupReconstructionCritical
NOTIFICATION-TYPE
Description: Two or more disks are failed and the RAID protection is in critical state for over a considerable period of time. If an additional disk fails, there might be permanent loss of data. Action: Make sure there is/are spare disk(s) in the system.
1.3.6.1.4.1.19746.2.0.5091current
diskUnknown
NOTIFICATION-TYPE
Description: Disk is unknown. Action: Add disk to the system.
1.3.6.1.4.1.19746.2.0.5092current
lowSpares
NOTIFICATION-TYPE
Description: Not enough spare disks can be detected for this tier. There may be failed disks or connectivity issues with disks or enclosures. Action: Replace any failed or absent disks. Check enclosure connectivity.
1.3.6.1.4.1.19746.2.0.5094current
unsupportedConfigurationROL
NOTIFICATION-TYPE
Description: Raid on LUN from 4.8 is no longer supported. Please follow instruction on how to increase usable space in your filesystem. Action: 1) migrate data away 2) do a filesystem destroy 3) add your LUN 4) migrate data back
1.3.6.1.4.1.19746.2.0.5095current
cpismissing
NOTIFICATION-TYPE
Description: An archive unit is missing which could result in failure to access files in that unit. Action: - check power connection of each shelf. - check data cables of each shelf. - if a hardware problem is found and fixed, restart the files system and verify that the archive unit is online. - If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5500current
containerMarkedInvalid
NOTIFICATION-TYPE
Description: The restorer filesystem has detected a data integrity check failure due to hardware/software problems. There is potential for data loss or corruption and needs immediate attention. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5501current
smiMrc
NOTIFICATION-TYPE
Description: BIOS SMI MRC interrupt Action: Check if system memory size has been decreased due to a DIMM has been disabled. If yes, replace the bad DIMM. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.5502current
nvramBatteryLowChargeAlert
NOTIFICATION-TYPE
Description: The NVRAM battery is charging, but is below the threshold. The filesystem will not start until the battery charge reaches the threshold. Action: Wait for the battery charge to reach threshold. If the battery does not reach threshold within 3 hours, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.5508current
ext3NvlogDisabled
NOTIFICATION-TYPE
Description: DDOS RAID log is disabled due to a problem with the NVRAM subsystem. Action: Check for other NVRAM-related alerts and follow the action described in those alerts.
1.3.6.1.4.1.19746.2.0.5527current
enclosureMixType
NOTIFICATION-TYPE
Description: An unsupported mix of enclosure models have been detected. For example, a mixture of ES30s and ES20s. Action: Refer to the configuration guide for valid cabling configurations.
1.3.6.1.4.1.19746.2.0.5528current
replPathTooLong
NOTIFICATION-TYPE
Description: Path is too long Action: Shorten the path.
1.3.6.1.4.1.19746.2.0.5531current
compromisedEncryptionKeys
NOTIFICATION-TYPE
Description: Data on disk may be at risk of disclosure. Data encrypted with the compromised keys should be re-encrypted before shipping the disks. One can get the list of compromised keys either from CLI or Enterprise Manager. Action: Start file system cleaning to re-encrypt the affected data. For extended retention systems, run space reclamation to re-encrypt affected data in the archive tier. Note, these operations will take a long time to complete.
1.3.6.1.4.1.19746.2.0.6001current
newEncryptionKey
NOTIFICATION-TYPE
Description: Old key is still used for encrypting new data. The file system needs to be restarted to activate the new key. Action: Restart the filesystem.
1.3.6.1.4.1.19746.2.0.6002current
encryptionKeyTableFull
NOTIFICATION-TYPE
Description: Encryption key table is full. No new keys can be added until some keys are deleted. Action: Free up key table space by deleting an unused key and then add the new key.
1.3.6.1.4.1.19746.2.0.6003current
uncertifiedFirmware
NOTIFICATION-TYPE
Description: Firmware version is not compatible with this version of DDOS and may cause unexpected behavior. Action: The firmware must be updated as soon as possible, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6004current
filesystemNVRAMDataLoss
NOTIFICATION-TYPE
Description: Filesystem cannot be enabled because of NVRAM mismatch. This can happen because of an improper headswap or NVRAM card replacement operation. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6005current
mtreeQuotaSoftLimit
NOTIFICATION-TYPE
Description: The Soft Limit Quota for this MTree has been reached. This will not affect the operation of the system and is only a warning. If a Quota Hard Limit is set for this MTree, you are approaching that limit and operations writing data to this MTree may fail if the hard limit is reached. Action: To clear this alert, either raise the quota limits or reduce the data in the MTree by deleting files.
1.3.6.1.4.1.19746.2.0.6007current
mtreeQuotaHardLimit
NOTIFICATION-TYPE
Description: The Hard Limit Quota for this MTree has been reached. No more data will be written to this MTree. If a backup operation was running, it probably failed and must be restarted after clearing this condition. Action: To clear this alert, either raise the Quota Hard Limit for this MTree, or reduce the data in the MTree by deleting files.
1.3.6.1.4.1.19746.2.0.6008current
interfaceConnectivityDown
NOTIFICATION-TYPE
Description: Network connectivity on this interface is down. This interface is not pingable and cannot be used to send or receive any data. All data transfers using this interface will fail. Action: Please view the Hardware->Network GUI page, or use the 'net show settings' and 'net show config' CLIs to check the current configuration. Make sure that the cable is securely connected to both endpoints and that the interfaces on both ends are properly configured. Otherwise the cable or network hardware could be faulty and may need to be replaced.
1.3.6.1.4.1.19746.2.0.6009current
interfaceConnectivityIntermittent
NOTIFICATION-TYPE
Description: Network connectivity on this interface is intermittent. Data may not be sent or received successfully. Data transfers using this interface may experience performance degradation or intermittent failures. Action: Please view the Hardware->Network GUI page, or use the 'net show settings' and 'net show config' CLIs to check the current configuration. Make sure that the cable is securely connected to both endpoints and that the interfaces on both ends are properly configured. Otherwise the cable or network hardware could be faulty and may need to be replaced. If the network is configured properly and the problem still persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6010current
interfaceMisconfiguration
NOTIFICATION-TYPE
Description: Network interface configuration problem detected. This may be a result of changing the NIC hardware without reconfiguring the interface. This could indicate an unsupported configuration, network environment or hardware problem. A misconfigured interface can potentially cause connectivity problems on subsequent reboots. Action: Please view the Hardware->Network GUI page, or use 'net show settings', 'net config' and 'net show hardware' to check network configuration. Try to fix the problem by reconfiguring the interface with 'net config'.
1.3.6.1.4.1.19746.2.0.6011current
recoverFromNVRAMFailed
NOTIFICATION-TYPE
Description: Due to NVRAM issues, filesystem has been disabled in order to maintain data integrity. No backups will run until this problem is resolved. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6013current
cleaningError
NOTIFICATION-TYPE
Description: Unable to reclaim unused space and this may impact the ability to backup. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6014current
bMCPartialHang
NOTIFICATION-TYPE
Description: BMC firmware is not responsive. Action: Use CLI or Enterprise Manager to check fan, voltage, and power supply readings. If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC. Wait until all LEDS are off. Reinsert the power cables and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6015current
fileMigrationError
NOTIFICATION-TYPE
Description: File migration is suspended until this problem is resolved. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6016current
unusableHostCertificate
NOTIFICATION-TYPE
Description: Enterprise Manager will not start up using the imported certificate. However, it will start up using the default self-signed certificate. Following is the list of possible causes of this alert, - the file system is locked - the system passphrase is missing - the imported certificate is corrupted Action: Unlock the file system if it is locked. Enter the system passphrase if it is missing. Delete and reimport the current host certificate if it is corrupted. In all cases, the Enterprise Manager needs to be restarted. If the condition persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6017current
missingHostCertificate
NOTIFICATION-TYPE
Description: The imported certificate is missing. However, the Enterprise Manager will start up using the default self-signed certificate. Action: If you want to use your own certificate, import it again.
1.3.6.1.4.1.19746.2.0.6018current
foreignEnclosure
NOTIFICATION-TYPE
Description: The enclosure is unusable by the filesystem. Storage configuration can not be modified while a foreign device is present. Action: If this is expected as part of a chassis swap or chassis upgrade, proceed with the headswap operation to make the foreign filesystem available. Otherwise contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6019current
interfaceConnectivityUpAndRunning
NOTIFICATION-TYPE
Description: Network interface is up and running for a period of time after experiencing instability. Action: No action needed.
1.3.6.1.4.1.19746.2.0.6020current
tcpZeroWindowAlert
NOTIFICATION-TYPE
Description: The TCP connection is active but data is not being transferred. This may cause other communication failures. Action: Check the remote application that uses this TCP connection. Check the network path between the local and remote systems. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6101current
insecureEncryptedReplication
NOTIFICATION-TYPE
Description: Encrypted replication is configured between this system and the remote host. The remote host is running a DDOS version that does not support a fully secure communication protocol. Unauthorized individuals may be able to intercept and decrypt the replicated data. Action: Upgrade the remote system to a release that supports the desired communication protocol. Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6102current
nvramHWAlert
NOTIFICATION-TYPE
Description: The NVRAM card is not in a usable state. The file system cannot be accessed until the fault is corrected or the NVRAM card is replaced. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6504current
nvramEnvAlert
NOTIFICATION-TYPE
Description: The temperature sensor on the NVRAM card or the remote battery detected a temperature that is higher than the warning threshold. If there are other environmental alerts, this may indicate a cooling problem where the system is installed. If there are no other environmental alerts, this may indicate a problem with this component. When the temperature is reduced, this alert will clear. Action: Check cooling and airflow around the system unit. Remove any blockage, or ensure the environmental systems are operating correctly, and the environment is at a normal temperature. If there is no problem in the environment, or if only the NVRAM or remote battery are reporting this problem, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6505current
nvramEventHWAlert
NOTIFICATION-TYPE
Description: NVRAM firmware detects an NVRAM card hardware fault. Action: The NVRAM card may need to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6506current
nvramBattAlert
NOTIFICATION-TYPE
Description: The remote battery for an NVRAM card is not in a usable state. The file system cannot be accessed until the fault is corrected or the NVRAM remote battery is replaced. Action: Check NVRAM battery status. Check the cables between the remote battery and the power source, and between the remote battery and the NVRAM card. If the cables are correctly connected and the problem persists, Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6507current
nvramCondAlert
NOTIFICATION-TYPE
Description: The NVRAM battery power or charging has been set as disabled. This condition is either the result of an explicit setting, or indicates a fault in the NVRAM card or battery unit. Action: If the NVRAM battery power was explicitly disabled, enable it using the reverse of the procedure used to disable it. If not, reboot the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6508current
upgradeFailure
NOTIFICATION-TYPE
Description: During the upgrade process, there was an error that requires manual intervention. The system is not usable. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6509current
upgradeCompleted
NOTIFICATION-TYPE
Description: The DD OS upgrade is completed successfully. The system will be ready to use when the filesystem is enabled. Action: No action required.
1.3.6.1.4.1.19746.2.0.6510current
mailserverError
NOTIFICATION-TYPE
Description: There is a problem communicating with the configured mail server. The system will not be able to send out any email notifications that includes alerts, autosupports and daily summary emails. Action: Make sure that the mail server is configured correctly. Verify the configured mail server by sending out a test email from the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6511current
invalidNICSlot
NOTIFICATION-TYPE
Description: Network interface cards must be installed in their designated slots. The network card may not function correctly when installed in the wrong slot. Action: Please make sure that the Network interface card is installed in a valid slot.
1.3.6.1.4.1.19746.2.0.6512current
unsupportedNIC
NOTIFICATION-TYPE
Description: An unsupported network interface card is installed in the system. Having an unsupported card installed in the system can cause unexpected errors. Action: Remove the card from system.
1.3.6.1.4.1.19746.2.0.6513current
sASHBAFailure
NOTIFICATION-TYPE
Description: Storage is no longer accessible through this HBA. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6514current
sASHBAErrors
NOTIFICATION-TYPE
Description: A SAS HBA has detected correctable errors exceeding the warning threshold. This will reduce throughput and may indicate a failing HBA. Action: If this condition persists for more than 24 hours, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6515current
unsupportedSASDevice
NOTIFICATION-TYPE
Description: A SAS HBA has reported a device that is not recognized. This device is not usable and may adversely affect the system. Action: Identify the device and remove it from the topology. If you believe it is a supported device, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6516current
fanFault
NOTIFICATION-TYPE
Description: A hardware fault has been detected in an enclosure cooling fan. This may allow the enclosure to overheat. Action: The fan must be replaced. Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6517current
powerSupplyInputFault
NOTIFICATION-TYPE
Description: A power loss has been detected in an enclosure power supply. This can be caused by a loss of AC power to one power supply. Action: Check if AC main power is available to the system. Check if power supply cables are properly connected. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com to replace the power supply.
1.3.6.1.4.1.19746.2.0.6518current
powerSupplyFailure
NOTIFICATION-TYPE
Description: A power loss has been detected in an enclosure power supply. This can be caused by a failure in the power supply. Action: Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6519current
powerSupplyAbsent
NOTIFICATION-TYPE
Description: An enclosure power supply is absent. Action: Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6520current
unsupportedACVoltage
NOTIFICATION-TYPE
Description: The power supply for this enclosure is connected to an unsupported AC voltage. The system may operate at a reduced capacity or unexpectedly shut down. Action: Replace the input power with the supported voltage.
1.3.6.1.4.1.19746.2.0.6521current
iOModuleFault
NOTIFICATION-TYPE
Description: A fault has been detected with an I/O module and it will not function correctly. Action: The I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6522current
iOModuleInserted
NOTIFICATION-TYPE
Description: An I/O module has been inserted during system runtime. The I/O module will not be powered on until the system is restarted. Action: Restart the system to activate this module.
1.3.6.1.4.1.19746.2.0.6523current
mgmtModuleFault
NOTIFICATION-TYPE
Description: A fault has been detected in the management I/O module. Management functions requiring the I/O module will not work. Action: The management I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6524current
dIMMFailure
NOTIFICATION-TYPE
Description: A fault has been detected on a memory card. The memory may no longer be usable by the system and the system may not function with the reduced memory capacity. Action: The failing memory card must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6525current
sPFault
NOTIFICATION-TYPE
Description: A fault has been detected on the storage processor. The system may experience unexpected behavior. Action: The failed storage processor must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6526current
chassisFailure
NOTIFICATION-TYPE
Description: A fault has been detected in one of the chassis components. The system may experience unexpected behavior. Action: The chassis must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6527current
forcedControllerShutdown
NOTIFICATION-TYPE
Description: An environmental condition or hardware fault has been detected that may cause significant damage to the hardware or possible data loss, and the system unit is being shut down. Action: Check the environment, If the system environment is at a normal state, restart the system and review the alert history to determine the source of the problem. Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6528current
systemReset
NOTIFICATION-TYPE
Description: A critical failure caused the system to unexpectedly shut down. The system was able to boot successfully either because the fault was corrected, the fault was transient, or the system was able to boot without the component causing the fault. Action: Review the system for earlier alerts to determine the cause of the unexpected shut down. Check the system inventory to verify all components are configured as expected. If this alert is issued again, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6529current
duplicateAddressDetection
NOTIFICATION-TYPE
Description: This IP address has been detected on the network. Connections to this IP address will be adversely impacted. Action: Make sure the local and remote systems are using different IP addresses. Clear the alert once the problem is resolved.
1.3.6.1.4.1.19746.2.0.6530current
spaceReclRestartFailed
NOTIFICATION-TYPE
Description: Archive space reclamation was running before the last shutdown of the filesystem and could not be restarted automatically. Space will not be reclaimed in the archive tier until space reclamation is restarted. Action: Start space reclamation.
1.3.6.1.4.1.19746.2.0.6531current
spaceReclMissingUnit
NOTIFICATION-TYPE
Description: Archive units are missing. Space reclamation cannot run unless all configured units are attached. Space will not be reclaimed in the archive tier until space reclamation is restarted. Action: Return missing archive units to the system and start space reclamation.
1.3.6.1.4.1.19746.2.0.6532current
spaceReclUnitReclaimed
NOTIFICATION-TYPE
Description: All space on the archive unit has been reclaimed. This unit is available to reuse. Action: No action is required.
1.3.6.1.4.1.19746.2.0.6533current
spaceReclError
NOTIFICATION-TYPE
Description: Archive space reclamation has stopped due to the specified error. Space will not be reclaimed in the archive tier until the error condition is resolved and space reclamation is restarted. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6534current
enclosureHighTemp
NOTIFICATION-TYPE
Description: The temperature inside the enclosure is high and has exceeded the warning threshold.If no action is taken and the temperature continue to increase, the system will shut down. Action: If the temperature around the system unit is within the documented operating limits and the air flow is not blocked, Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6535current
unsupportedSystemType
NOTIFICATION-TYPE
Description: An unsupported system type has been detected and needs to be modified or replaced. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6536current
bMCHangShutdown
NOTIFICATION-TYPE
Description: While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating. Action: After the system is shut down, pull out all power cables from the controller to reset BMC. Wait until all LEDs are off, reinsert the power cables, and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6537current
expiredHostCertificate
NOTIFICATION-TYPE
Description: Communication using this certificate is vulnerable to disclosure. Action: Replace the host certificate with a valid certificate.
1.3.6.1.4.1.19746.2.0.6538current
sCSITGTInvalidRegistry
NOTIFICATION-TYPE
Description: A registry entry used in the SCSI Target system is invalid. The SCSI Target services, including VTL, DD-BOOST FC and VDISK will be inaccessible until this problem is resolved. Action: The registry entry must be corrected. Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6539current
encryptionKeyExportFailed
NOTIFICATION-TYPE
Description: The automatic export of the encryption keys failed. This could result in encrypted data being inaccessible. Action: Manually export the encryption keys.
1.3.6.1.4.1.19746.2.0.6540current
sSDEndOfLife
NOTIFICATION-TYPE
Description: The SSD has reached end of life and could fail at any time. The system may shut down unexpectedly if the drive is not replaced. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.6541current
tapeReposition
NOTIFICATION-TYPE
Description: The tape volume was adjusted to the last consistent data position during VTL recovery. Recent pending updates to the volume may have been discarded. Action: Verify that any backup sent to the affected tape at the time of this alert completed successfully. Reissue the backup if necessary.
1.3.6.1.4.1.19746.2.0.6542current
multipleDiskReadErrors
NOTIFICATION-TYPE
Description: There are too many disks reporting read errors in the same RAID group. As each of these disks completes reconstruction it will be failed. If the ongoing RAID reconstruction fails, there might be permanent loss of data. Action: Contact your contracted support provider or visit us online at https://support.emc.com to determine the number of drives that need to be replaced.
1.3.6.1.4.1.19746.2.0.6543current
missingCreplUnits
NOTIFICATION-TYPE
Description: The collection replication destination is not in a consistent state and will not be usable until matching retention units are added to the destination. Action: Add the required retention units to the collection replication destination.
1.3.6.1.4.1.19746.2.0.6544current
nvramBattEndOfLife
NOTIFICATION-TYPE
Description: The remote battery for NVRAM us currently usable but is approaching the end of its life. If the battery is not replaced before it reaches end of its life, the filesystem will be disabled. Action: To schedule a replacement, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.6545current
bMCFailure
NOTIFICATION-TYPE
Description: BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will be disabled. Action: Shut the system down and pull out all power cables from the controller to reset BMC. Wait until all LEDs are off, reinsert the power cables, and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7000current
unsupportedDriveModel
NOTIFICATION-TYPE
Description: This system only supports certain drive models. The unsupported drives are unusable and must be replaced for proper system operation. Action: Identify and remove/replace the unsupported drives. For assistance, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7001current
driveMixType
NOTIFICATION-TYPE
Description: Mixing drive types within an enclosure is not supported and may cause unexpected system behavior. Action: Ensure that all drives within the enclosure are of the same type. For assistance, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7002current
sMSUnresponsive
NOTIFICATION-TYPE
Description: The System Management Service has reached the maximum number of concurrent requests and has been unresponsive for over five minutes. This may indicate a serious condition that may need to be addressed by support. The system is unable to accept additional commands. Action: If this condition persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7500current
nISCommFailure
NOTIFICATION-TYPE
Description: Unable to query information from the NIS server. This could be a network problem or an authentication failure with the NIS server. This could prevent NIS servers from completing backups or restoring existing backups. This alert will clear when communication is established with the NIS server. Action: Verify network connection to the NIS server and verify NIS configurations for both systems. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com .
1.3.6.1.4.1.19746.2.0.7501current
unsupportedHardwareConfig
NOTIFICATION-TYPE
Description: Unsupported virtual machine hardware configuration was detected. This configuration may cause unexpected behavior. Action: Fix the hardware configuration to resolve the problem. If problem persists, restart the system.
1.3.6.1.4.1.19746.2.0.7502current
unsupportedVirtualCPU
NOTIFICATION-TYPE
Description: The current number of CPU sockets and cores in the virtual machine configuration is not valid for the current storage capacity. The file system will not be enabled. Action: Power off this virtual machine instance and change the virtual machine configuration to match the supported values. If you made this change to add storage capacity, you must add the additional capacity before enabling the file system.
1.3.6.1.4.1.19746.2.0.7503current
dNSUnresponsive
NOTIFICATION-TYPE
Description: No DNS servers responded to a DNS query. This may be caused by a network failure or a DNS server problem. System functions that require name address resolution will fail. Action: Check the network path and the DNS server to establish communication or remove the DNS entries and add host entries to the hosts table. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.7504current
nTPDFailed
NOTIFICATION-TYPE
Description: Network Time Protocol (NTP) daemon is not running. NTP daemon has detected a time difference between this system and the configured network time server (drift) greater than the configured maximum and has shut down. Action: Disable NTP. Verify time on the NTP server. Set system date/time to match the time on the NTP server. Enable NTP. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.7505current
invalidEnclosureTopology
NOTIFICATION-TYPE
Description: The cables connecting enclosures to the controller are not installed correctly. This can cause unpredictable system behavior. Recable the enclosures immediately. Action: Display the topology to identify the invalid path(s). Power down the system and cable the enclosures according to the cabling guide for your system.
1.3.6.1.4.1.19746.2.0.7506current
diskPathSpeedDegraded
NOTIFICATION-TYPE
Description: SAS connection speed is degraded and could reduce disk performance. Action: Check cable seating and replace if needed. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7507current
targetDriverPortOffline
NOTIFICATION-TYPE
Description: No connection is detected on the Fibre Channel Port. Action: If this port is not in use, please disable it. If port is being used, please restore Fibre Channel Port connectivity. Alert will be cleared when port is disabled or online.
1.3.6.1.4.1.19746.2.0.7508current
targetDriverPortOnline
NOTIFICATION-TYPE
Description: Fibre Channel Port is online. Action: No action required
1.3.6.1.4.1.19746.2.0.7509current
targetDriverPortCore
NOTIFICATION-TYPE
Description: An error occurred on the Fibre Channel Port that resulted in a HBA core. Action: Contact your contracted support provider or visit us online at https://support.emc.com to extract and analyze the HBA core.
1.3.6.1.4.1.19746.2.0.7510current
targetDriverPortMultipleCore
NOTIFICATION-TYPE
Description: An error occurred on the Fibre Channel Port that caused multiple HBA core attempts. The Fibre Channel Port is disabled. Action: Contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA.
1.3.6.1.4.1.19746.2.0.7511current
targetDriverPortFWLoadFailed
NOTIFICATION-TYPE
Description: The Fibre Channel Port is unable to load required firmware. The Fibre Channel Port is disabled. Action: Contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA.
1.3.6.1.4.1.19746.2.0.7512current
targetDriverPortUnreadable
NOTIFICATION-TYPE
Description: Unable to access one or more resources on the HBA. The Fibre Channel Port is disabled. Action: Contact contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA.
1.3.6.1.4.1.19746.2.0.7513current
targetDriverPortTooManyOsc
NOTIFICATION-TYPE
Description: The system has detected a Fibre Channel Port has been transitioning between online and offline too frequently. This may cause disruption in i/o. Action: Please ensure stable port connectivity. Disable the port if it is not in use.
1.3.6.1.4.1.19746.2.0.7514current
insufficientSpaceForEncryption
NOTIFICATION-TYPE
Description: Additional space is needed on the archive tier to encrypt the existing data. Free space up to 1% of data size may be required. Un-encrypted data will not get encrypted until sufficient space is available. Action: Make free space available in the archive tier by doing one or all of the following: 1. Delete any unwanted data in archive tier and run space-reclamation to reclaim free space. 2. Expand the archive unit by adding some storage, and run space-reclamation.
1.3.6.1.4.1.19746.2.0.7515current
dDFSRequiresReboot
NOTIFICATION-TYPE
Description: File system was unable to start because an abnormal internal condition was detected. Action: Reboot the system. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7516current
storageUnitStreamSoftLimit
NOTIFICATION-TYPE
Description: Stream soft limit quota for this storage-unit and type of stream has been exceeded. Crossing this limit may cause reduced performance as the system hard limits are reached. Action: To clear this alert, configure the backup application to use fewer concurrent streams. Otherwise, increase the soft limit quota on this storage-unit for this stream type.
1.3.6.1.4.1.19746.2.0.7517current
spaceReclSuspended
NOTIFICATION-TYPE
Description: Archive space reclamation has suspended due to the specified error. Space will not be reclaimed in the archive tier until the error condition is resolved and space reclamation is resumed. Action: Resume space reclamation after the underlying error condition is corrected. If problem persists, Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.7518current
metadataWarningThreshold
NOTIFICATION-TYPE
Description: Large amount of metadata has been created by the filesystem. Continuing without cleaning would cause the filesystem to enter into read-only mode. Action: Clean the filesystem as soon as possible. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7519current
mtreeCascadeNeedResync
NOTIFICATION-TYPE
Description: This Mtree is now a cascaded source. Since this mtree already has data, this replication context requires a resync to proceed. Action: To re-establish replication - Note the context information - break the context - reconfigure contexts on both source and destination - resync context on the source
1.3.6.1.4.1.19746.2.0.7520current
filesystemCorruption
NOTIFICATION-TYPE
Description: Filesystem processing detected some corruption. This may be isolated to a single file or multiple files, preventing you from reading the corrupted files. If a system file is affected, the filesystem could be disabled. Until this corruption is fixed, you will not be able to run cleaning, data-movement or space reclamation on the affected tier. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7521current
missingTierStorage
NOTIFICATION-TYPE
Description: Critical storage resources are unavailable, preventing the tier from functioning. Action: Verify all storage is functional and configured correctly. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7522current
spaceReclUnitError
NOTIFICATION-TYPE
Description: Space reclamation encountered an error and cannot proceed on the specified archive unit. If you have more than one archive unit, space reclamation will continue on the next unit. Space will not be reclaimed in this archive unit until the error condition is resolved and space reclamation finishes successfully on this unit. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.7523current
bMCFailureSysBBU
NOTIFICATION-TYPE
Description: BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will be disabled. Action: Shut the system down and remove all external power sources from the controller. Remove the system battery backup unit (BBU). Wait until all LEDs are off, reinsert the BBU, connect external power, and then power the system up. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.7524current
licenseExpiring
NOTIFICATION-TYPE
Description: The temporary license indicated is about to expire. The function provided by this license will cease to operate. Action: Contact your [account team] to purchase a license if you wish to continue to use this feature.
1.3.6.1.4.1.19746.2.0.8001current
licenseExpired
NOTIFICATION-TYPE
Description: The temporary license indicated has expired. The function provided by this license has stopped operating. Action: Contact your [account team] to purchase a license if you wish to use this feature.
1.3.6.1.4.1.19746.2.0.8002current
unsupportedEnclosurePSU
NOTIFICATION-TYPE
Description: A power supply has been detected in an enclosure which does not provide complete environmental information. This will not affect normal operations but should be replaced as soon as convenient. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10000current
unsupportedPowerSupply
NOTIFICATION-TYPE
Description: The installed power supply is an unsupported model. The system may exhibit unexpected behavior. Action: Replace the power supply with a supported model. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10001current
openFanDrawer
NOTIFICATION-TYPE
Description: Fan drawer is not closed securely. Failure to secure the fan drawer may allow the system to overheat and shut down. Action: Close and secure the fan drawer. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10002current
memoryRiserFault
NOTIFICATION-TYPE
Description: A critical failure has been detected in a memory riser. Memory attached to this riser may disappear from the system inventory. The system may exhibit unexpected behavior. Action: Contact your contracted support provider or visit us online at https://support.emc.com to replace the memory riser.
1.3.6.1.4.1.19746.2.0.10003current
pCILinkDegraded
NOTIFICATION-TYPE
Description: The system has detected that PCI communication speed is degraded. This will not cause the system to fail but may impact performance of affected components. Action: Reboot the system. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10004current
invalidHardwareCritical
NOTIFICATION-TYPE
Description: During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location. The filesystem cannot be enabled with the current hardware configuration. Action: View enclosure misconfiguration to determine the problem. For assistance, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10005current
invalidHardwareWarning
NOTIFICATION-TYPE
Description: During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location. Some components may not operate as expected. Action: View enclosure misconfiguration to determine the problem. For assistance, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10006current
correctableErrorWarning
NOTIFICATION-TYPE
Description: The system has detected excessive correctable errors on a component that may indicate a hardware failure. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10007current
spuriousInterruptDisabled
NOTIFICATION-TYPE
Description: Excessive spurious hardware messages have been detected that may indicate a hardware failure. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10008current
corruptEncryptionKeys
NOTIFICATION-TYPE
Description: File system was locked as the encryption keys cannot not be validated. One or more encryption keys could be corrupt. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10009current
duplicateVTLPoolNames
NOTIFICATION-TYPE
Description: VTL directory pool and a VTL mtree pool have been detected with the same name. Viewing pool information will only retrieve tapes from the mtree pool. Tapes in the directory pool will not be visible to DataDomain system administration interfaces. Backups and restores using the directory pool will operate normally. Action: Rename one of the pools to make the name unique. The duplicate pool name may have been created as part of a replication pair.If problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10010current
generalHardwareFailure
NOTIFICATION-TYPE
Description: A critical failure has been detected in one or more chassis components. The system may exhibit unexpected behavior. Action: Contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10011current
iOModuleMacFault
NOTIFICATION-TYPE
Description: A Mac fault has been detected with an I/O module and it will not function correctly. Action: The I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10013current
storageMigrationCannotResume
NOTIFICATION-TYPE
Description: The system has detected a condition which prevented the storage migration from continuing and has suspended the data copy phase. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10500current
storageMigrationCopyComplete
NOTIFICATION-TYPE
Description: All data has been moved from old enclosures to the new enclosures. Storage migration must be finalized to decommission old enclosures and add new capacity to the file system. Action: Finalize the storage migration.
1.3.6.1.4.1.19746.2.0.10501current
storageMigrationUserSuspend
NOTIFICATION-TYPE
Description: An administrator has suspended the data copy phase of storage migration. Data copy cannot proceed until it is manually resumed. Action: Resume the storage migration.
1.3.6.1.4.1.19746.2.0.10502current
cMTaskEnded
NOTIFICATION-TYPE
Description: A long running task has ended. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10503current
physicalCapacityMeasurementTasksLost
NOTIFICATION-TYPE
Description: File system has been disabled either by a failure or user action. Physical-capacity-measurement samples for these tasks are no longer available. Action: Restart physical-capacity-measurement sample tasks that have not completed.
1.3.6.1.4.1.19746.2.0.10504current
physicalCapacityMeasurementTasksLostMTree
NOTIFICATION-TYPE
Description: MTree replication was broken or resynced causing one or more physical-capacity-measurement sample tasks to be cancelled. Physical-capacity-measurement samples for these tasks are no longer available. Action: Restart physical-capacity-measurement sample tasks that have not completed for this MTree.
1.3.6.1.4.1.19746.2.0.10505current
physicalCapacityMeasurementScheduleFailed
NOTIFICATION-TYPE
Description: A physical-capacity-measurement sample task that was scheduled to run was unable to start due to an error. Some or all of the physical-capacity-measurement samples for these tasks are not available. Action: Review scheduled physical-capacity-measurement sample task errors to determine the reason for the failure. Resubmit failed tasks if needed.
1.3.6.1.4.1.19746.2.0.10506current
historicalDatabaseFailoverError
NOTIFICATION-TYPE
Description: Historical database failover failed. Action: Contact your contracted support provider or visit us online at https://support.emc.com to help debug the problem.
1.3.6.1.4.1.19746.2.0.10507current
hAdegraded
NOTIFICATION-TYPE
Description: A condition has been detected causing the configured HA system to be degraded. Any failover attempt will not succeed. Action: Display the HA detailed status to determine the failed component. Repairing the failed component can return the HA system to available state.
1.3.6.1.4.1.19746.2.0.10508current
upgradeInProgress
NOTIFICATION-TYPE
Description: DD OS upgrade is in progress. The system will not be available for backup and restore operations. The alert will be cleared after the upgrade operation is complete. Action: Allow the upgrade operation to complete. If the upgrade takes longer than usual, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10509current
hAofflineErrors
NOTIFICATION-TYPE
Description: Critical system errors have been detected causing the configured HA system to be in offline state. Access to system services may be unavailable. Action: Review exisiting alerts. Fixing issues identified by these alerts may resolve this alert. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10510current
suspendedMReplMissingUnits
NOTIFICATION-TYPE
Description: Mtree replication on this context cannot continue until all archive units used by this Mtree are online. Replication will resume automatically once all archive units come online. Action: Return missing archive units to the system to resume MTree replication for this context. If the archive units cannot be restored, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10511current
foreignPack
NOTIFICATION-TYPE
Description: The enclosure pack is unusable by the file system. Storage configuration can not be modified while a foreign device is present. Action: If this is expected as part of a chassis swap or chassis upgrade, proceed with the headswap operation to make the foreign filesystem available. Otherwise contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10512current
vDiskSCSITargetMismatch
NOTIFICATION-TYPE
Description: VDisk configuration does not match SCSI Target configuration. Non-matching devices are not available and must be deleted or repaired. Action: Contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10513current
hATimeOutOfSync
NOTIFICATION-TYPE
Description: Timestamps of logs and system events will not match between the HA nodes. This condition will not have an effect on HA functionality or system operation. Action: Set the time on the standby node to match the active node. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
1.3.6.1.4.1.19746.2.0.10514current
enclosureMixDriveType
NOTIFICATION-TYPE
Description: An unsupported mix of enclosures with different drive types may impact performance and lead to unexpected system behavior. Action: Recable the enclosures to eliminate the unsupported mix. Refer to the configuration guide for valid cabling configurations.
1.3.6.1.4.1.19746.2.0.10515current
missingSlaveInterface
NOTIFICATION-TYPE
Description: The bonded interface has been created with the remaining interfaces and may experience degraded performance or reduced failover capability. Action: Replace the network interface or reconfigure the bonded interface to restore functionality. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com
1.3.6.1.4.1.19746.2.0.10523current
vTLEnabled
NOTIFICATION-TYPE
Description: VTL is enabled. VTL functionality is available to the user. Action: Some backup applications may need manual rescanning for devices.
1.3.6.1.4.1.19746.2.0.11105current
vTLDisabled
NOTIFICATION-TYPE
Description: VTL is disabled. VTL functionality is unavailable to the user. Action: No Action required.
1.3.6.1.4.1.19746.2.0.11106current

Conformance

NameOIDStatus
dataDomainMibCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement this MIB module.
1.3.6.1.4.1.19746.0.1.1deprecated
dataDomainMibComplianceRev1
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement this MIB module.
1.3.6.1.4.1.19746.0.1.2deprecated
dataDomainMibComplianceRev2
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement this MIB module.
1.3.6.1.4.1.19746.0.1.3deprecated
dataDomainMibComplianceRev3
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement this MIB module.
1.3.6.1.4.1.19746.0.1.4deprecated
dataDomainMibComplianceRev4
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement this MIB module.
1.3.6.1.4.1.19746.0.1.5deprecated
dataDomainMibComplianceRev5
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement this MIB module.
1.3.6.1.4.1.19746.0.1.6current
environmentalsGroup
OBJECT-GROUP
A collection of objects providing environmental monitoring information.
1.3.6.1.4.1.19746.0.2.1current
nvramGroup
OBJECT-GROUP
A collection of objects providing nvram monitoring information.
1.3.6.1.4.1.19746.0.2.2current
fileSystemGroup
OBJECT-GROUP
A collection of objects providing file system monitoring information.
1.3.6.1.4.1.19746.0.2.3deprecated
alertsGroup
OBJECT-GROUP
A collection of objects providing alert monitoring information.
1.3.6.1.4.1.19746.0.2.4current
statisticsGroup
OBJECT-GROUP
A collection of objects providing statistics information.
1.3.6.1.4.1.19746.0.2.5current
internalDiskStorageGroup
OBJECT-GROUP
A collection of objects providing internal disk monitoring information.
1.3.6.1.4.1.19746.0.2.7current
externalUnmanagedDiskStorageGroup
OBJECT-GROUP
A collection of objects providing external unmanaged disk monitoring information.
1.3.6.1.4.1.19746.0.2.8current
basicNotificationsGroup
NOTIFICATION-GROUP
A collection of objects providing basic notifications.
1.3.6.1.4.1.19746.0.2.9deprecated
internalDiskStorageNotificationsGroup
NOTIFICATION-GROUP
A collection of objects providing internal disk storage notifications.
1.3.6.1.4.1.19746.0.2.10deprecated
replGroup
OBJECT-GROUP
a collection of objects providing replication pair config and monitoring information.
1.3.6.1.4.1.19746.0.2.11current
nfsGroup
OBJECT-GROUP
A collection of objects providing NFS monitoring information.
1.3.6.1.4.1.19746.0.2.12current
cifsGroup
OBJECT-GROUP
A collection of objects providing CIFS monitoring information.
1.3.6.1.4.1.19746.0.2.13deprecated
vtlGroup
OBJECT-GROUP
A collection of objects providing VTL monitoring information.
1.3.6.1.4.1.19746.0.2.14current
ddboostGroup
OBJECT-GROUP
A collection of objects providing DDBoost monitoring information.
1.3.6.1.4.1.19746.0.2.15deprecated
ddsystemGroup
OBJECT-GROUP
A collection of objects providing system monitoring information.
1.3.6.1.4.1.19746.0.2.16deprecated
artGroup
OBJECT-GROUP
A collection of objects providing art monitoring information.
1.3.6.1.4.1.19746.0.2.17current
mtreeGroup
OBJECT-GROUP
A collection of objects providing mtree monitoring information.
1.3.6.1.4.1.19746.0.2.18current
enclosureGroup
OBJECT-GROUP
A collection of objects providing enclousure information.
1.3.6.1.4.1.19746.0.2.19current
managedObjectsGroup
OBJECT-GROUP
A collection of objects providing ddms system information.
1.3.6.1.4.1.19746.0.2.20current
networkGroup
OBJECT-GROUP
A collection of objects providing network information.
1.3.6.1.4.1.19746.0.2.21current
fileSystemGroupRev1
OBJECT-GROUP
A collection of objects providing file system monitoring information.
1.3.6.1.4.1.19746.0.2.22current
ddsystemGroupRev1
OBJECT-GROUP
A collection of objects providing system monitoring information.
1.3.6.1.4.1.19746.0.2.23current
smtGroup
OBJECT-GROUP
A collection of objects providing Secure Multi-Tenancy (SMT) information.
1.3.6.1.4.1.19746.0.2.24current
quotaGroup
OBJECT-GROUP
A collection of objects providing quota information.
1.3.6.1.4.1.19746.0.2.25current
ddboostGroupRev1
OBJECT-GROUP
A collection of objects providing DDBoost monitoring information.
1.3.6.1.4.1.19746.0.2.26deprecated
ddboostGroupRev2
OBJECT-GROUP
A collection of objects providing DDBoost monitoring information.
1.3.6.1.4.1.19746.0.2.27current
highAvailabilityGroup
OBJECT-GROUP
A collection of objects providing High Availability information.
1.3.6.1.4.1.19746.0.2.28current
scsitargetObjectGroup
OBJECT-GROUP
A collection of objects providing Scsitarget information.
1.3.6.1.4.1.19746.0.2.29current
cifsGroupRev1
OBJECT-GROUP
A collection of objects providing CIFS monitoring information.
1.3.6.1.4.1.19746.0.2.30current
generatedNotificationsGroup
NOTIFICATION-GROUP
A collection of objects providing notifications, automatically generated by build.
1.3.6.1.4.1.19746.0.2.5000current