MIBs Depot

CTRON-WAN-MIB

Registered at
1.3.6.1.4.1.52.4.1.2.7.1.1
1.3.6.1.4.1.52.4.1.2.7.1.2
1.3.6.1.4.1.52.4.1.2.7.1.3
1.3.6.1.4.1.52.4.1.2.7.1.4
1.3.6.1.4.1.52.4.1.2.7.1.5
1.3.6.1.4.1.52.4.1.2.7.1.6
1.3.6.1.4.1.52.4.1.2.7.1.7
1.3.6.1.4.1.52.4.1.2.7.1.8
Namespace
enterasys
Source file
CTRON-WAN-MIB
Digest
sha256:5dd297f322d81ee5cb35c1bc5c12ca4b284d2b264485f20b62a31a11a9a00182

Imports

FromSymbols
CTRON-MIB-NAMESctWan
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CTRON-MIB-NAMES
CTRON-OIDS
CTRON-WAN-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
DLCI
type
Index
type

Objects

NameOIDSyntaxAccessStatus
ctWanConnection
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.1
wanNumConnections
OBJECT-TYPE
This objects describes the number of wan connections on the platform. A wan connection may have one or two physical ports of which only one can be active at any time.
1.3.6.1.4.1.52.4.1.2.7.1.1.1INTEGERread-onlymandatory
wanConnTable
OBJECT-TYPE
A list of wan connection entries. The number of wan connection entries is given by the value of wanNumConnections.
1.3.6.1.4.1.52.4.1.2.7.1.1.2not-accessiblemandatory
wanConnEntry
OBJECT-TYPE
A wan connection entry containing objects relating to the particular wan connection.
1.3.6.1.4.1.52.4.1.2.7.1.1.2.1not-accessiblemandatory
wanConnIndex
OBJECT-TYPE
A unique value for each wan connection. Its value ranges between 1 and the value wanNumConnections.
1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.1INTEGERread-onlymandatory
wanConnNumPhysPorts
OBJECT-TYPE
The number of physical ports that exist on this wan connection.
1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.2INTEGERread-onlymandatory
wanConnDefaultPhysPort
OBJECT-TYPE
The default physical port for this connection. This indicates the physical port that should be used on this wan connection. If redundancy is not enabled, this physical port will always be used. If redundancy is enabled, the physical port given here will be considered the primary physical port. The value of this object must be set to the index of a valid physical port (wanPhysPortIndex) for this wan connection.
1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.3INTEGERread-writemandatory
wanConnActivePhysPort
OBJECT-TYPE
The physical port that is currently active for this wan connection. The value of this object indicates the wanPhysPortIndex for the active port.
1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.4INTEGERread-onlymandatory
wanPhysPortTable
OBJECT-TYPE
A list of the descriptions of the physical ports of this platform. The number of entries is given by the value of wanConnNumPhysPort for each Wan Connection.
1.3.6.1.4.1.52.4.1.2.7.1.1.3not-accessiblemandatory
wanPhysPortEntry
OBJECT-TYPE
A physical port entry. It contains objects relating to a given physical port
1.3.6.1.4.1.52.4.1.2.7.1.1.3.1not-accessiblemandatory
wanPhysPortConnectionIndex
OBJECT-TYPE
A value indicating the wan connection this physical port is located on.
1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.1INTEGERread-onlymandatory
wanPhysPortIndex
OBJECT-TYPE
A unique value for each physical port on a wan connection. Its value ranges between 1 and the value wanConnNumPhysPorts.
1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.2INTEGERread-onlymandatory
wanPhysPortType
OBJECT-TYPE
The type of physical port that this entry describes. None indicates that the physical port has no connector.
1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.3INTEGER {none(1), t1(2), e1(3), synchronous(4), dds(5), di(6), hdsl(7), bri(8), ds30(9), t1DDS(10)}read-onlymandatory
wanPhysPortSpecificMib
OBJECT-TYPE
This object identifies an instance of the index object in the first group of objects in the MIB specific to the physical port.
1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.4OBJECT IDENTIFIERread-onlymandatory
wanInterfaceTable
OBJECT-TYPE
The interface table for a physical port on a wan connection. It is a list of items that are pertinent to the interfaces that are part of this physical port. The number of entries is dependent on the wanPhysPortType for the interface. If the wanPhysPortType is none, there will be no entries in the table for the port. If the wanPhysPortType is t1, there will be 24 entries in this table for the port. If the wanPhysPortType is e1, there will be 30 entries in this table for the port. If the wanPhysPortType is synchronous, there will be one entry in this table for the port.
1.3.6.1.4.1.52.4.1.2.7.1.1.4not-accessiblemandatory
wanInterfaceEntry
OBJECT-TYPE
A wan connection physical port interface entry. It contains objects relating to an interface that is defined for this physical port and this wan connection.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1not-accessiblemandatory
wanInterfaceConnectionIndex
OBJECT-TYPE
This value is the wan connection that this interface exists on.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.1INTEGERread-onlymandatory
wanInterfacePhysPortIndex
OBJECT-TYPE
This value is the physical port of the wan connection that this interface exists on.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.2INTEGERread-onlymandatory
wanInterfaceEntryIndex
OBJECT-TYPE
A unique value for each interface of this physical port. It is a value between 1 and the number of interfaces that exist for the current port. The number of interfaces for each type of port is: 24 for a port type (wanPhysPortType) of 't1', 30 for a port type of 'e1', and 1 for a port type of 'synchronous'. There will be no entries if the port type is 'none'.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.3INTEGERread-onlymandatory
wanInterfaceEntryIfIndex
OBJECT-TYPE
The ifIndex of the interface. This is the index of this entry in the ifTable.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.4INTEGERread-onlymandatory
wanInterfaceEntryProtocol
OBJECT-TYPE
The protocol that should be run on this interface. Values are equivalent to those defined for ifType in Mib-II. Accepted values are product dependent.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.5INTEGERread-writemandatory
wanInterfaceEntryCompression
OBJECT-TYPE
Indicates whether data compression should take place on this interface.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.6INTEGER {on(1), off(2)}read-writemandatory
wanInterfaceEntryMTU
OBJECT-TYPE
The MTU to be negotiated for this interface. This will not be updated with the actual MTU, which can be found in the ifTable.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.7INTEGERread-writemandatory
wanInterfaceEntryLineCoding
OBJECT-TYPE
This object describes the variety of Zero Code suppression on this interface. For an interface on a Ds1 Port, the valid values depend on the value of the Ds1ConfigLineCode object. If that object is set to ds1xB8ZS, then this object can be set to none, JBZS, or InvHDLC. If the value of Ds1ConfigLineCode is set to ds1xAMI, then this object can only be set to JBZS, or InvHDLC. For an interface on a Synchronous Port, the valid values are none or InvHDLC. JBZS refers to Jammed Bit Zero suppression, which forces a 1 bit every 8 bit periods. InvHDLC refers to inverting the HDLC data for the interface. None refers to a mode in which some other means, such as with the Ds1ConfigLineCode object set to dsx1B8ZS, is used to insure pulse density requirements.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.8INTEGER {none(1), jBZS(2), invHDLC(3)}read-writemandatory
wanInterfaceEntryCrcLength
OBJECT-TYPE
The Length of the CRC for this interface. Not all platforms will allow all options.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.9INTEGER {sixteen-bits(1), thirty-two-bits(2)}read-writemandatory
wanInterfaceEntryLexProtocolEnable
OBJECT-TYPE
This switch acts in concert with the wanInterfaceEntryProtocol object. To activate LEX, this object should first be set to enable (1), then set the wanInterfaceEntryProtocol to PPP. The enable will have no effect if PPP is not selected. If the wanInterfaceEntryProtocol is selected first, the default NCP of BNCP will be selected. To De-select LEX, you must set this object to disable (2), and wanInterfaceEntryProtocol to NONE or reset the device. Just selecting disable (2) will not tear down the connection.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.10INTEGER {enable(1), disable(2)}read-writedeprecated
wanInterfaceEntryLexProtocolStatus
OBJECT-TYPE
This object reflects the current state of the link. The device is said to be bound to the router when the physical link is OK, the LEX negotiation is successful, and the router has been configured correctly to communicate with this particular LAN Extender.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.11INTEGER {bound(1), unbound(2)}read-onlydeprecated
wanInterfaceEntryCompRatio
OBJECT-TYPE
The ratio of uncompressed to compressed transmitted data. If the data compression status is off, 1:1 will be displayed
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.12OCTET STRING (SIZE(6))read-onlymandatory
wanInterfaceEntryCompStatus
OBJECT-TYPE
On indicates that the compression has been successfully negotiated and is operating. Off indicates that the compression negotiation has failed and compression is not operating at this time, or compression has been terminated by either peer.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.13INTEGER {on(1), off(2)}read-onlymandatory
wanInterfaceEntryBackUpIfEnable
OBJECT-TYPE
This object is used to select the Call-backup option. A value of 1 is used to enable the option and a value of 2 to disable it.
1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.14INTEGER {enable(1), disable(2)}read-writemandatory
ctWanDs1
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.2
wanDs1ExtensionsTable
OBJECT-TYPE
This table is an extension to the standard ds1 configuration table. It is a list of items that are pertinent to ds1 ports on a platform. There is one entry per ds1 physical port on the platform
1.3.6.1.4.1.52.4.1.2.7.1.2.1not-accessiblemandatory
wanDs1ExtensionsEntry
OBJECT-TYPE
A ds1 extensions entry containing objects relating to the particular ds1 physical port
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1not-accessiblemandatory
wanDs1ExtensionsEntryIndex
OBJECT-TYPE
A unique value for each ds1 physical port on the platform.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.1INTEGERread-onlymandatory
wanDs1ExtensionsNumInterfaces
OBJECT-TYPE
The number of interfaces on this physical port. This number indicates the number of entries this physical port uses in the ifTable.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.2INTEGERread-onlymandatory
wanDs1ExtensionsToggleFracTable
OBJECT-TYPE
Setting this object to 1 will cause the Ds1 Fractional Table to be updated with the new values, as entered. Setting this object to 2, will cause the Ds1 Fractional Table to view as the table being entered. Setting this object to 3, will cause the Ds1 Fractional Table to be the table that is currently in use, regardless of any changes being entered. Setting this object to 4, will cause any changes that have been made to the Ds1 Fractional Table since the last update-table to be deleted. For physical ports of type synchronous, this object will have no affect, and will always return a 1.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.3INTEGER {update-table(1), display-new(2), display-old(3), restore-old(4)}read-writemandatory
wanDs1ExtensionsLineBuildOut
OBJECT-TYPE
The line build out setting for this ds1 physical port. Unknown indicates that the setting is neither readable or writable.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.4INTEGER {unknown(1), zero(2), minus-7point5(3), minus-15(4), a133to266feet(5), a266to399feet(6), a399to533feet(7), a533to655feet(8)}read-writemandatory
wanDs1ExtensionsCFADuration
OBJECT-TYPE
The length of time (in seconds), that the ds1 port will remain in the Carrier Failure Alarm state after the alarm condition has cleared.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.5INTEGER (1..15)read-writemandatory
wanDs1ExtensionsDIEnable
OBJECT-TYPE
Enables or disables Drop and Insert functionality on a D/I WPIM. If enabled, all zero assigned timeslots will designate D/I interface channels, if disabled all zero channels will designate dummy channels as on a T1 or E1. If this object is set to diDataEnabled the zero channels will designate D/I interface channels and data to and from the device will be transmitted or received on the D/I port instead of the N/I port.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.6INTEGER {enable(1), disable(2), diDataEnabled(3)}read-writemandatory
wanDs1ExtensionsTotalValidIntervals
OBJECT-TYPE
The number of previous intervals for which valid data was collected for the DS1 mib, which is currently RFC1406. This counter is similar to RFC1406 dsx1ValidIntervals except that the count represents the total number of complete 15 minute intervals since the ds1 interface has been online, and does not stop at the 24 hour period.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.7Counterread-onlymandatory
wanDs1ExtensionsBertTestMode
OBJECT-TYPE
This object is used to request that a type of process be in control of the testing function. This is used to differentiate between automated test procedures and those manually controlled by a user. When read, this object reflects which type of process is actually in control of the testing function. The implementation is free to prioritize or deny requests in a proprietary manner.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.8INTEGER {none(1), internal(2), manual(3)}read-writemandatory
wanDs1ExtensionsBertRun
OBJECT-TYPE
Controls the sending of test data over this physical port. The data is a pattern described by wanDs1ExtensionsBertTestPattern.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.9INTEGER {disabled(1), enabled(2)}read-writemandatory
wanDs1ExtensionsBertCurrentResults
OBJECT-TYPE
Indicates the results of the testing for the last completed sampling period. A non-negative number is the error rate in bits per million bits.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.10INTEGERread-onlymandatory
wanDs1ExtensionsBertCumulativeResults
OBJECT-TYPE
Indicates the total number of errors since the testing was enabled. It is not a rate.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.11INTEGERread-onlymandatory
wanDs1ExtensionsBertPeakResults
OBJECT-TYPE
Indicates the highest value of wanDs1ExtensionsBertCurrentResults since the testing was enabled. A non-negative number is the error rate in bits per million bits.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.12INTEGERread-onlymandatory
wanDs1ExtensionsBertAverageResult
OBJECT-TYPE
Indicates the average value of wanDs1ExtensionsBertCurrentResults since the testing was enabled. A non-negative number is the error rate in bits per million bits.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.13INTEGERread-onlymandatory
wanDs1ExtensionsBertTestPattern
OBJECT-TYPE
This object is used to specify the pattern of the test data.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.14INTEGER {patternOther(1), pattern1s(2), pattern63(3), pattern511(4), pattern2047(5), pattern3in24(6), patternQRSS(7)}read-writemandatory
wanDs1ExtensionsBertSamplePeriod
OBJECT-TYPE
This object is the duration of time in seconds at which the current test results will be periodically written to wanDs1ExtensionsBertCurrentResults. The range is 1 to 3600, with a default value of 10.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.15INTEGERread-writemandatory
wanDs1ExtensionsBertNumPeriods
OBJECT-TYPE
The number of sampling periods that have elapsed during the current test run.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.16Counterread-onlymandatory
wanDs1ExtensionsBertTestTraps
OBJECT-TYPE
This object is used to enable or disable the sending of a trap at the conclusion of the measurement period. The trap will contain the information described by ctDs1BertCurrentResults. The default value is disabled.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.17INTEGER {disabled(1), enabled(2)}read-writemandatory
wanDs1ExtensionsBertDataStatus
OBJECT-TYPE
This object provides the operating status of the transmission of test data packets.
1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.18INTEGER {idle(1), waitingForLink(2), waitingForLoopback(3), running(4)}read-onlymandatory
ctWanRs232
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.3
wanRs232ExtensionsTable
OBJECT-TYPE
This table is an extension to the standard rs232-like mib. It is a list of items that are pertinent to rs232-like ports on a platform. There is one entry per synchronous physical port on the platform.
1.3.6.1.4.1.52.4.1.2.7.1.3.1not-accessiblemandatory
wanRs232ExtensionsEntry
OBJECT-TYPE
A rs232-like extensions entry containing objects relating to the particular rs232-like physical port.
1.3.6.1.4.1.52.4.1.2.7.1.3.1.1not-accessiblemandatory
wanRs232ExtensionsEntryIndex
OBJECT-TYPE
A unique value for each rs232-like physical port on the platform.
1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.1INTEGERread-onlymandatory
wanRs232ExtensionsCTSEnable
OBJECT-TYPE
This object indicates whether the platform should generate CTS. When disabled the platform will not generate CTS, when enabled, the platform will generate CTS. The actual state of the CTS line is available in the rs-232 like mib.
1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.2INTEGER {enable(1), disable(2)}read-writemandatory
wanRs232ExtensionsDSREnable
OBJECT-TYPE
This object indicates whether the platform should generate DSR. When disabled the platform will not generate DSR, when enabled, the platform will generate DSR. The actual state of the DSR line is available in the rs-232 like mib.
1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.3INTEGER {enable(1), disable(2)}read-writemandatory
ctFrDcp
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.4
frDcpCircuitTable
OBJECT-TYPE
A table containing data compression information about specific Data Link Connection Identifiers and corresponding virtual circuit. This information is used to support the frCircuitTable following RFC-1315.
1.3.6.1.4.1.52.4.1.2.7.1.4.1not-accessiblemandatory
frDcpCircuitEntry
OBJECT-TYPE
The data compression information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.52.4.1.2.7.1.4.1.1not-accessiblemandatory
frDcpCircuitIfIndex
OBJECT-TYPE
The ifIndex value of ifEntry that this DCP virtual circuit object is layered onto.
1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.1Indexread-onlymandatory
frDcpCircuitDlci
OBJECT-TYPE
The Data Link Connection Identifier for this DCP virtual circuit object.
1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.2DLCIread-onlymandatory
frDcpCircuitEnable
OBJECT-TYPE
Indicates whether data compression should take place on this particular end side virtual circuit.
1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.3INTEGER {on(1), off(2)}read-writemandatory
frDcpCircuitStatus
OBJECT-TYPE
On indicates that the compression has been successfully negotiated and is operating. Off indicates that the compression negotiation has failed and compression is not operating at this time, or compression has been terminated by either peer.
1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.4INTEGER {on(1), off(2)}read-onlymandatory
frDcpCircuitRatio
OBJECT-TYPE
The ratio of uncompressed to compressed transmitted data. If the data compression status is off, 1:1 will be displayed
1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.5OCTET STRING (SIZE(5))read-onlymandatory
ctDDS
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.5
ddsConfigTable
OBJECT-TYPE
The DDS Configuration Table
1.3.6.1.4.1.52.4.1.2.7.1.5.1not-accessiblemandatory
ddsConfigEntry
OBJECT-TYPE
An Entry in the DDS Configuration Table
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1not-accessiblemandatory
ddsLineIndex
OBJECT-TYPE
A unique value for each dds physical port on the platform
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.1INTEGER (1..2147483647)read-onlymandatory
ddsIfIndex
OBJECT-TYPE
Index associated with this dds physical port
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.2INTEGER (1..2147483647)read-onlymandatory
ddsLineMode
OBJECT-TYPE
DDS-PRI is full duplex 56k link, No framing in loop data so loop speed is also 56k. Data stream: --d1 d2 d3 d4 d5 d6 d7-- DDS-CC is full duplex 64k link. Does not require framing bit but uses a same format as SC, ninth bit position is lumped with primary channel and not used for control. Loop speed is 72k, Primary channel rate is 64k. --d1 d2 d3 d4 d5 d6 d7 F d8--
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.3INTEGER {ddsPri(1), ddsCc(2)}read-writemandatory
ddsLineCoding
OBJECT-TYPE
This object describes the variety of Zero Code suppression on this interface. JBZS refers to Jammed Bit Zero suppression, which forces a 1 bit every 8 bit periods. None refers to a mode in which some other means is used to insure pulse density requirements.
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.4INTEGER {ddsNone(1), ddsJBZS(2), otherLineCode(3)}read-writemandatory
ddsLoopbackConfig
OBJECT-TYPE
This variable represents the loop-back configuration of the DDS interface. ddsNoLoop means the interface is not in loop-back state, and LineLoop means the the received data is looped back out.
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.5INTEGER {ddsNoLoop(1), ddsLineLoop(2)}read-writemandatory
ddsLineStatus
OBJECT-TYPE
This describes the current operational status of DDS line.
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.6INTEGER {ddsNoAlarm(1), ddsLossOfSignal(2), ddsOutOfService(3), ddsOutOfFrame(4)}read-onlymandatory
ddsTxClockSource
OBJECT-TYPE
The source of Transmit clock. ddsLoopTiming - indicates that the recovered receive clock is used as transmit clock. ddsLocalTiming - indicates that a local clock source is used.
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.7INTEGER {ddsLoopTiming(1), ddsLocalTiming(2)}read-writemandatory
ddsPortInSpeed
OBJECT-TYPE
This variable describes the current operational receive speed of DDS line. It is a read only value based entirely on DDS type (CC or PRI).
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.8INTEGERread-onlymandatory
ddsPortOutSpeed
OBJECT-TYPE
This variable describes the current operational transmit speed of DDS line. It is a read only value based entirely on DDS type CC or PRI
1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.9INTEGERread-onlymandatory
ctDs1Alarms
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.6
ds1AlarmsGlobalConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.6.1
ds1AlarmGlobalAdmin
OBJECT-TYPE
Used to enable and disable the DS1 Alarm Monitoring Application for all DS1 circuits on the device.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.1INTEGER {disabled(1), enabled(2)}read-writemandatory
ds1AlarmGlobalAutoRecovery
OBJECT-TYPE
Used to enable and disable the DS1 Alarm Automatic Recovery feature for all DS1 circuits on the device. For those devices that support ds1 alarm monitoring, but do not support the automatic recovery feature, this object always returns disabled, and performs no action when written.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.2INTEGER {disabled(1), enabled(2)}read-writemandatory
ds1AlarmGlobalTrapEnable
OBJECT-TYPE
Used to enable and disable the DS1 Alarm SNMP Trap generation feature for all DS1 circuits on the device. This object operates in conjunction with configuration of objects in the ctron-trap-mib.txt
1.3.6.1.4.1.52.4.1.2.7.1.6.1.3INTEGER {disabled(1), enabled(2)}read-writemandatory
ds1AlarmGlobalESCount
OBJECT-TYPE
Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.4INTEGER (1..300)read-writemandatory
ds1AlarmGlobalESInterval
OBJECT-TYPE
Used in conjuction with ds1AlarmGlobalESCount to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.5INTEGER (1..15)read-writemandatory
ds1AlarmGlobalBPVErrorRate
OBJECT-TYPE
Used to specify the negative exponent of 10, used in monitoring Bipolar Violations (Code Violations for E1) over intervals defined by ds1AlarmGlobalBPVInterval. For example, for a ds1AlarmGlobalBPVErrorRate value of 6 used with a ds1AlarmGlobalBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not support detect bipolar violations, this object always returns the default, and performs no action when written.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.6INTEGER (5..9)read-writemandatory
ds1AlarmGlobalBPVInterval
OBJECT-TYPE
Used to specify the interval, used in monitoring Bipolar Violations (Code Violations for E1) with thresholds defined by ds1AlarmGlobalBPVErrorRate. For example, for a ds1AlarmGlobalBPVErrorRate value of 6 used with a ds1AlarmGlobalBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not detect bipolar violations, this object always returns the default, and performs no action when written.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.7INTEGER (1..15)read-writemandatory
ds1AlarmGlobalManualRecovery
OBJECT-TYPE
To cause a manual recovery to occur on all Ds1 circuits, this object is set to a 1. It is always read as a 1. The recovery will occur only when automatic recovery is disabled.
1.3.6.1.4.1.52.4.1.2.7.1.6.1.8INTEGER {recover(1)}read-writemandatory
ds1AlarmConfigTable
OBJECT-TYPE
Table containing objects used to configure DS1 alarm functionality on a per DS1 basis.
1.3.6.1.4.1.52.4.1.2.7.1.6.2not-accessiblemandatory
ds1AlarmConfigEntry
OBJECT-TYPE
A description of a single entry.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1not-accessiblemandatory
ds1PhysNum
OBJECT-TYPE
The value for this object is equal to the value of a unique physical connection identifier associated with this DS1 which is clearly labeled on the device. For those products that do not have a DS1 identifier labeled on the device, the value for this object is the same as rfc1406 dsx1LineIndex.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.1INTEGERread-onlymandatory
ds1AlarmAdmin
OBJECT-TYPE
Used to enable and disable the DS1 Alarm Monitoring Application for this DS1 circuit.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.2INTEGER {disabled(1), enabled(2)}read-writemandatory
ds1AlarmAutoRecovery
OBJECT-TYPE
Used to enable and disable the DS1 Alarm Automatic Recovery feature for this DS1 circuit. For those devices that support ds1 alarm monitoring, but do not support the automatic recovery feature, this object always returns disabled, and performs no action when written.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.3INTEGER {disabled(1), enabled(2)}read-writemandatory
ds1AlarmTrapEnable
OBJECT-TYPE
Used to enable and disable the DS1 Alarm SNMP Trap generation feature for this DS1 circuit. This object operates in conjunction with configuration of objects in the ctron-trap-mib.txt
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.4INTEGER {disabled(1), enabled(2)}read-writemandatory
ds1AlarmESCount
OBJECT-TYPE
Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.5INTEGER (1..300)read-writemandatory
ds1AlarmESInterval
OBJECT-TYPE
Used in conjuction with ctDs1AlarmESCount to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.6INTEGER (1..15)read-writemandatory
ds1AlarmBPVErrorRate
OBJECT-TYPE
Used to specify the negative exponent of 10, used in monitoring Bipolar Violations (Code Violations for E1) over intervals defined by ds1AlarmBPVInterval. For example, for a ds1AlarmBPVErrorRate value of 6 used with a ds1AlarmBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not support detect bipolar violations, this object always returns the default, and performs no action when written.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.7INTEGER (5..9)read-writemandatory
ds1AlarmBPVInterval
OBJECT-TYPE
Used to specify the interval, used in monitoring Bipolar Violations (Code Violations for E1) with thresholds defined by ds1AlarmBPVErrorRate. For example, for a ds1AlarmBPVErrorRate value of 6 used with a ds1AlarmBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not support detect bipolar violations, this object always returns the default, and performs no action when written.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.8INTEGER (1..15)read-writemandatory
ds1AlarmManualRecovery
OBJECT-TYPE
To cause a manual recovery to occur, this object is set to a 1. It is always read as a 1. The recovery will occur only when automatic recovery is disabled.
1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.9INTEGER {recover(1)}read-writemandatory
ctIPPQFilters
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.7
ipPQConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.7.1
ipPQAdmin
OBJECT-TYPE
Used to enable and disable the IP Priority Queue Forwarding Application.
1.3.6.1.4.1.52.4.1.2.7.1.7.1.1INTEGER {disabled(1), enabled(2)}read-writemandatory
iPPQMaxEntries
OBJECT-TYPE
Returns the maximum number of IP address entries supported by the IP Priority Queue application on this device.
1.3.6.1.4.1.52.4.1.2.7.1.7.1.2INTEGERread-onlymandatory
iPPQNumEntries
OBJECT-TYPE
Get the number of IP address entries currently programmed in the ipPQAddressTable.
1.3.6.1.4.1.52.4.1.2.7.1.7.1.3INTEGERread-onlymandatory
iPPQAddAddress
OBJECT-TYPE
Add an IP address to the ipPQAddressTable. Always read as a 0.0.0.0.
1.3.6.1.4.1.52.4.1.2.7.1.7.1.4IpAddressread-writemandatory
iPPQDelAddress
OBJECT-TYPE
Delete an IP address from the ipPQAddressTable. Always read as a 0.0.0.0.
1.3.6.1.4.1.52.4.1.2.7.1.7.1.5IpAddressread-writemandatory
ipPQAddressTable
OBJECT-TYPE
Table containing IP addresses, used in an IP Priority Queue Forwarding function.
1.3.6.1.4.1.52.4.1.2.7.1.7.2not-accessiblemandatory
ipPQAddressEntry
OBJECT-TYPE
A description of a single entry.
1.3.6.1.4.1.52.4.1.2.7.1.7.2.1not-accessiblemandatory
ipPQAddressId
OBJECT-TYPE
A unique value identifying an element in a sequence of IP PQ address entries.
1.3.6.1.4.1.52.4.1.2.7.1.7.2.1.1INTEGER (1..65535)read-onlymandatory
ipPQIPAddress
OBJECT-TYPE
Returns an IP address associated with a specific entry in this table.
1.3.6.1.4.1.52.4.1.2.7.1.7.2.1.2IpAddressread-onlymandatory
ctWanHDSLExt
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.7.1.8
ctWanHDSLPerformance15mTable
OBJECT-TYPE
HDSL 15 minute performance table. This table provides the accumulated counts of errored seconds (ES) and unavailable seconds (UAS) for the HDSL line including the local, remote units and any doublers in between during a 15 minutes period for the last 24 hours. The table is indexed by the non-empty slot in the device and the 15-minute history slot within the last 24 hours period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1not-accessiblemandatory
ctWanHDSLPerformance15mEntry
OBJECT-TYPE
Entries in the 15 minute performance table
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1not-accessiblemandatory
ctWanHDSLPerformance15mConnIndex
OBJECT-TYPE
Identify the HDSL connection within the device, indexing from 1 to the maximum allowed number of HDSL connections in the device.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.1INTEGERread-onlymandatory
ctWanHDSLPerformance15mSlotIndex
OBJECT-TYPE
Define which 15-minute slot history of the HDSL within the 24 hour period. Indexing from 1 - 97 with the first index representing the current 15-minute history
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.2INTEGERread-onlymandatory
ctWanHDSLHLULoop1UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the local line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.3INTEGERread-onlymandatory
ctWanHDSLHLULoop1ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the local line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.4INTEGERread-onlymandatory
ctWanHDSLHLULoop2UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the local line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.5INTEGERread-onlymandatory
ctWanHDSLHLULoop2ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the local line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.6INTEGERread-onlymandatory
ctWanHDSLHRULoop1UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the remote line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.7INTEGERread-onlymandatory
ctWanHDSLHRULoop1ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the remote line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.8INTEGERread-onlymandatory
ctWanHDSLHRULoop2UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the remote line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.9INTEGERread-onlymandatory
ctWanHDSLHRULoop2ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the remote line unit during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.10INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop1UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.11INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop1ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the first doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.12INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop2UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.13INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop2ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the first doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.14INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop1UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.15INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop1ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the first doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.16INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop2UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.17INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop2ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the first doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.18INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop1UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.19INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop1ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the second doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.20INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop2UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.21INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop2ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the second doubler unit's network side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.22INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop1UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.23INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop1ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the second doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.24INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop2UAS15m
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.25INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop2ES15m
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the second doubler unit's customer side during the 15-minute period.
1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.26INTEGERread-onlymandatory
ctWanHDSLPerformance24hTable
OBJECT-TYPE
HDSL 24-hour performance table. This table provides the accumulated counts of errored seconds (ES) and unavailable seconds (UAS) for the HDSL line including the local, remote units and any doublers in between during a 24-hour period for the last 7 days. The table is indexed by the non-empty slot in the device and the 24-hour history slot within the last 7 days period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2not-accessiblemandatory
ctWanHDSLPerformance24hEntry
OBJECT-TYPE
Entries in the 24-hour ctWanHDSLPerformance table
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1not-accessiblemandatory
ctWanHDSLPerformance24hConnIndex
OBJECT-TYPE
Identify the HDSL connection within the device, indexing from 1 to the maximum allowed number of HDSL connections in the device.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.1INTEGERread-onlymandatory
ctWanHDSLPerformance24hSlotIndex
OBJECT-TYPE
Define which 24-hour slot history of the HDSL within the last 7 days period. Indexing from 1 - 8 with the first index representing the current 24 hour history
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.2INTEGERread-onlymandatory
ctWanHDSLHLULoop1UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the local line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.3INTEGERread-onlymandatory
ctWanHDSLHLULoop1ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the local line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.4INTEGERread-onlymandatory
ctWanHDSLHLULoop2UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the local line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.5INTEGERread-onlymandatory
ctWanHDSLHLULoop2ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the local line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.6INTEGERread-onlymandatory
ctWanHDSLHRULoop1UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the remote line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.7INTEGERread-onlymandatory
ctWanHDSLHRULoop1ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the remote line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.8INTEGERread-onlymandatory
ctWanHDSLHRULoop2UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the remote line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.9INTEGERread-onlymandatory
ctWanHDSLHRULoop2ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the remote line unit during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.10INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop1UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.11INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop1ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the first doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.12INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop2UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.13INTEGERread-onlymandatory
ctWanHDSLDb1NetworkLoop2ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the first doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.14INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop1UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.15INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop1ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the first doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.16INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop2UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.17INTEGERread-onlymandatory
ctWanHDSLDb1CustomerLoop2ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the first doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.18INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop1UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.19INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop1ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the second doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.20INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop2UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.21INTEGERread-onlymandatory
ctWanHDSLDb2NetworkLoop2ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the second doubler unit's network side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.22INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop1UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.23INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop1ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 1 of the second doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.24INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop2UAS24h
OBJECT-TYPE
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.25INTEGERread-onlymandatory
ctWanHDSLDb2CustomerLoop2ES24h
OBJECT-TYPE
Errored seconds (ES) on LOOP 2 of the second doubler unit's customer side during the 24-hour period.
1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.26INTEGERread-onlymandatory
ctWanHDSLStatisticsTable
OBJECT-TYPE
This table collects the statistics for the Signal noise ratio (SNR), and the pulse attenuation of the HDSL line, including the local, remote units and the doublers in between.
1.3.6.1.4.1.52.4.1.2.7.1.8.3not-accessiblemandatory
ctWanHDSLStatisticsEntry
OBJECT-TYPE
Entries of the HDSL statistics table
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1not-accessiblemandatory
ctWanHDSLStatisticsHLUConnIndex
OBJECT-TYPE
Identify the HDSL connection occupied in the device, indexing from 1 to the maximum allowed connections in the device.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.1INTEGERread-onlymandatory
ctWanHDSLSNRHLULoop1
OBJECT-TYPE
Current SNR on LOOP 1 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.2INTEGERread-onlymandatory
ctWanHDSLSNRLowHLULoop1
OBJECT-TYPE
Lowest SNR on LOOP 1 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.3INTEGERread-onlymandatory
ctWanHDSLSNRHighHLULoop1
OBJECT-TYPE
Highest SNR on LOOP 1 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.4INTEGERread-onlymandatory
ctWanHDSLSNRHLULoop2
OBJECT-TYPE
Current SNR on LOOP 2 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.5INTEGERread-onlymandatory
ctWanHDSLSNRLowHLULoop2
OBJECT-TYPE
Lowest SNR on LOOP 2 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.6INTEGERread-onlymandatory
ctWanHDSLSNRHighHLULoop2
OBJECT-TYPE
Highest SNR on LOOP 2 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.7INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationHLULoop1
OBJECT-TYPE
pulse Attenuation on LOOP 1 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.8INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationHLULoop2
OBJECT-TYPE
pulse Attenuation on LOOP 2 of the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.9INTEGERread-onlymandatory
ctWanHDSLBitStat1HLU
OBJECT-TYPE
A byte value which contains product specific information: bit 0 - System in AIS on the local line unit. 1 - System in AIS on the remote line unit. 2 - Channels are reversed on the remote line unit. 3 - Channels are reversed on the doubler 1. 4 - Channels are reversed on the doubler 2. 5 - Power is fed to the next unit on the local line unit. 6 - Power is fed to the next unit on the remote line unit. 7 - Smartloop is active on remote line unit. (HiGain only)
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.10INTEGERread-onlymandatory
ctWanHDSLSNRHRULoop1
OBJECT-TYPE
Current SNR on LOOP 1 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.11INTEGERread-onlymandatory
ctWanHDSLSNRLowHRULoop1
OBJECT-TYPE
Lowest SNR on LOOP 1 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.12INTEGERread-onlymandatory
ctWanHDSLSNRHighHRULoop1
OBJECT-TYPE
Highest SNR on LOOP 1 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.13INTEGERread-onlymandatory
ctWanHDSLSNRHRULoop2
OBJECT-TYPE
Current SNR on LOOP 2 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.14INTEGERread-onlymandatory
ctWanHDSLSNRLowHRULoop2
OBJECT-TYPE
Lowest SNR on LOOP 2 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.15INTEGERread-onlymandatory
ctWanHDSLSNRHighHRULoop2
OBJECT-TYPE
Highest SNR on LOOP 2 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.16INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationHRULoop1
OBJECT-TYPE
pulse Attenuation on LOOP 1 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.17INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationHRULoop2
OBJECT-TYPE
pulse Attenuation on LOOP 2 of the remote line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.18INTEGERread-onlymandatory
ctWanHDSLDs1FrameHRU
OBJECT-TYPE
Byte value shows DS1 frame and code information for the remote line unit (HiGain only): bit 0:1 - 0 - frame format is SF. 1 - frame format is ESF. 2 - Frame format is unframed. 3 - no activity. bit 2:3 - reserved. bit 4 - 0 - line code is AMI 1 - line code is B8ZS. bit 5:7 - reserved.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.19INTEGERread-onlymandatory
ctWanHDSLSNRDb1NetworkLoop1
OBJECT-TYPE
Current SNR on LOOP 1 of doubler 1's network side
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.20INTEGERread-onlymandatory
ctWanHDSLSNRLowDb1NetworkLoop1
OBJECT-TYPE
Lowest SNR on LOOP 1 of doubler 1's network side
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.21INTEGERread-onlymandatory
ctWanHDSLSNRHighDb1NetworkLoop1
OBJECT-TYPE
Highest SNR on LOOP 1 of doubler 1's network side
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.22INTEGERread-onlymandatory
ctWanHDSLSNRDb1NetworkLoop2
OBJECT-TYPE
Current SNR on LOOP 2 of doubler 1's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.23INTEGERread-onlymandatory
ctWanHDSLSNRLowDb1NetworkLoop2
OBJECT-TYPE
Lowest SNR on LOOP 2 of doubler 1's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.24INTEGERread-onlymandatory
ctWanHDSLSNRHighDb1NetworkLoop2
OBJECT-TYPE
Highest SNR on LOOP 2 of doubler 1's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.25INTEGERread-onlymandatory
ctWanHDSLSNRDb1CustomerLoop1
OBJECT-TYPE
Current SNR on LOOP 1 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.26INTEGERread-onlymandatory
ctWanHDSLSNRLowDb1CustomerLoop1
OBJECT-TYPE
Lowest SNR on LOOP 1 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.27INTEGERread-onlymandatory
ctWanHDSLSNRHighDb1CustomerLoop1
OBJECT-TYPE
Highest SNR on LOOP 1 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.28INTEGERread-onlymandatory
ctWanHDSLSNRDb1CustomerLoop2
OBJECT-TYPE
Current SNR on LOOP 2 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.29INTEGERread-onlymandatory
ctWanHDSLSNRLowDb1CustomerLoop2
OBJECT-TYPE
Lowest SNR on LOOP 2 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.30INTEGERread-onlymandatory
ctWanHDSLSNRHighDb1CustomerLoop2
OBJECT-TYPE
Highest SNR on LOOP 2 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.31INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb1NetworkLoop1
OBJECT-TYPE
Pulse Attenuation on LOOP 1 of doubler 1's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.32INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb1NetworkLoop2
OBJECT-TYPE
Pulse Attenuation on LOOP 2 of doubler 1's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.33INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb1CustomerLoop1
OBJECT-TYPE
Pulse Attenuation on LOOP 1 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.34INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb1CustomerLoop2
OBJECT-TYPE
pulse Attenuation on LOOP 2 of doubler 1's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.35INTEGERread-onlymandatory
ctWanHDSLSNRDb2NetworkLoop1
OBJECT-TYPE
Current SNR on LOOP 1 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.36INTEGERread-onlymandatory
ctWanHDSLSNRLowDb2NetworkLoop1
OBJECT-TYPE
Lowest SNR on LOOP 1 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.37INTEGERread-onlymandatory
ctWanHDSLSNRHighDb2NetworkLoop1
OBJECT-TYPE
Highest SNR on LOOP 1 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.38INTEGERread-onlymandatory
ctWanHDSLSNRDb2NetworkLoop2
OBJECT-TYPE
Current SNR on LOOP 2 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.39INTEGERread-onlymandatory
ctWanHDSLSNRLowDb2NetworkLoop2
OBJECT-TYPE
Lowest SNR on LOOP 2 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.40INTEGERread-onlymandatory
ctWanHDSLSNRHighDb2NetworkLoop2
OBJECT-TYPE
Highest SNR on LOOP 2 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.41INTEGERread-onlymandatory
ctWanHDSLSNRDb2CustomerLoop1
OBJECT-TYPE
Current SNR on LOOP 1 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.42INTEGERread-onlymandatory
ctWanHDSLSNRLowDb2CustomerLoop1
OBJECT-TYPE
Lowest SNR on LOOP 1 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.43INTEGERread-onlymandatory
ctWanHDSLSNRHighDb2CustomerLoop1
OBJECT-TYPE
Highest SNR on LOOP 1 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.44INTEGERread-onlymandatory
ctWanHDSLSNRDb2CustomerLoop2
OBJECT-TYPE
Current SNR on LOOP 2 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.45INTEGERread-onlymandatory
ctWanHDSLSNRLowDb2CustomerLoop2
OBJECT-TYPE
Lowest SNR on LOOP 2 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.46INTEGERread-onlymandatory
ctWanHDSLSNRHighDb2CustomerLoop2
OBJECT-TYPE
Highest SNR on LOOP 2 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.47INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb2NetworkLoop1
OBJECT-TYPE
Pulse Attenuation on LOOP 1 of doubler 2's network side
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.48INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb2NetworkLoop2
OBJECT-TYPE
Pulse Attenuation on LOOP 2 of doubler 2's network side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.49INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb2CustomerLoop1
OBJECT-TYPE
pulse Attenuation on LOOP 1 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.50INTEGERread-onlymandatory
ctWanHDSLPulseAttenuationDb2CustomerLoop2
OBJECT-TYPE
Pulse Attenuation on LOOP 2 of doubler 2's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.51INTEGERread-onlymandatory
ctWanHDSLTestTable
OBJECT-TYPE
Test result for the HDSL line, the current test results only apply to the local line unit.
1.3.6.1.4.1.52.4.1.2.7.1.8.4not-accessiblemandatory
ctWanHDSLTestEntry
OBJECT-TYPE
Entries of the HDSL test results table.
1.3.6.1.4.1.52.4.1.2.7.1.8.4.1not-accessiblemandatory
ctWanHDSLTestHLUConnIndex
OBJECT-TYPE
Identify the slot of the HDSL within the device that the user wants to conduct the line unit test. Slot number start from 1 to maximum slots available in the device.
1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.1INTEGERread-onlymandatory
ctWanHDSLTestMode
OBJECT-TYPE
This object may only be successfully set on a master device. When this object is set, the local unit's test mode is defined by these values when set: 1 - Normal operation 3 - Self test mode 4 - PROM check test 5 - External RAM test 6 - DS1 loop test 7 - MUX-DMUX test 9 - Analog loopback mode 13 - Transceiver mode When getting this object, the value returned represents the last value this object had been set to.
1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.2INTEGERread-writemandatory
ctWanHDSLHLUTestResult
OBJECT-TYPE
Test result for the local line unit (1 - test failed, 0 - success): bit 0 - 2180 DS1 frame sync test (HiGain only) 1 - 2180 DS1 data test (HiGain only) 2 - LIU DS1 frame sync test (HiGain only) 3 - LIU DS1 data test (HiGain only) 4 - External DS1 frame sync test (HiGain only) 5 - External DS1 data test. 6 - Mux sync test on HDSL LOOP 1 7 - Mux sync test on HDSL LOOP 2 8 - Reserved. 9 - Mux frame error test on HDSL LOOP 1 10 - Mux frame error test on HDSL LOOP 2 11 - Mux CRC test on HDSL LOOP 1 12 - Mux CRC test on HDSL LOOP 2 13 - Mux DL test on HDSL LOOP 1 14 - Mux DL test on HDSL LOOP 2 15 - Analog loopback test. 16 - Digital loop test. 17 - HGF HDSL loop test (HiGain only) 18 - HGF write/readback test (HiGain only) 19 - HGF poll lock test (HiGain only). 20 - HGF activity monitor test (HiGain only). 21 - HGF zeroes TX and detect test (HiGain only). 22 - HGF ones TX and detect test (HiGain only). 23 - Transceiver poll test on HDSL LOOP 1 24 - Transceiver poll test on HDSL LOOP 2 25 - PROM check test. 26 - External RAM test. 27 - Non-Volatile RAM test.
1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.3INTEGERread-onlymandatory
ctWanHDSLHRUTestResult
OBJECT-TYPE
Test results for the remote line unit, Bit definitions correspond to those defined for ctWanHDSLHLUTestResult.
1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.4INTEGERread-onlymandatory
ctWanHDSLAlarmsTable
OBJECT-TYPE
This table collects the existing alarms information for the HDSL line, including the local, remote line units and the doublers.
1.3.6.1.4.1.52.4.1.2.7.1.8.5not-accessiblemandatory
ctWanHDSLAlarmsEntry
OBJECT-TYPE
Entries for the ctWanHDSL alarms information
1.3.6.1.4.1.52.4.1.2.7.1.8.5.1not-accessiblemandatory
ctWanHDSLAlarmsHLUConnIndex
OBJECT-TYPE
Identify which HDSL connection within the device that the user wants to retrieve the alarm information.
1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.1INTEGERread-onlymandatory
ctWanHDSLAlarmsBackplane
OBJECT-TYPE
Specific information that's related to the HDSL alarms, each bit in the two bytes value has the following meaning if set: Bit 0 : Local Loss of Signal on DS1 line (HiGain only). 1 : Remote Loss of Signal on DS1 list (HiGain only). 2 - 7 : reserved. 8 : Loss of Sync word on LOOP 1 of the local line unit. 9 : Loss of Sync word on LOOP 2 of the local line unit. 10 : Loss of Sync word on LOOP 1 of the first doubler. 11 : Loss of sync word on LOOP 2 of the first doubler. 12 : Loss of Sync word on LOOP 1 of the second doubler. 13 : Loss of sync word on LOOP 2 of the second doubler.
1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.2INTEGERread-onlymandatory
ctWanHDSLAlarmsES
OBJECT-TYPE
A two bytes value for the Errored Second indication of the HDSL line unit, including local, remote line units and the doublers. each bit in the two bytes value has the following meaning if set: Bit 0 : Errored Second on LOOP 1 of local line unit. 1 : Errored Second on LOOP 2 of local line unit. 2 : Errored Second on LOOP 1 of remote line unit. 3 : Errored Second on LOOP 2 of remote line unit. 4 : Errored Second on LOOP 1 of local line unit's network side. 5 : Errored Second on LOOP 2 of local line unit's network side. 6 : Errored Second on LOOP 1 of local line unit's customer side. 7 : Errored Second on LOOP 2 of local line unit's customer side.
1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.3INTEGERread-onlymandatory
ctWanHDSLAlarmHistoryTable
OBJECT-TYPE
HDSL Alarm History table. This table provides the accumulated counts of Errored Seconds (ES) and Loss of Sync words (LOS) as well as the time stamp of the above events occurred for both of the HDSL loops. The time stamps show the date in MMDDYYYYHHMM format.
1.3.6.1.4.1.52.4.1.2.7.1.8.6not-accessiblemandatory
ctWanHDSLAlarmHistoryEntry
OBJECT-TYPE
Entries in the Alarm History table
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1not-accessiblemandatory
ctWanHDSLAlarmHistoryConnIndex
OBJECT-TYPE
Defines which HDSL connection's alarm history within the device.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.1INTEGERread-onlymandatory
ctWanHDSLAlHistLLOSFirst
OBJECT-TYPE
Time stamp of the first time the DS1 Loss Of Signal (LOS) occurred on the local side of the HDSL.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.2DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistLLOSLast
OBJECT-TYPE
Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred on the local side of the HDSL.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.3DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistLLOSCurrent
OBJECT-TYPE
Set if the DS1 Loss Of Signal (LOS) still occurred on the local side of the HDSL.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.4INTEGERread-onlymandatory
ctWanHDSLAlHistLLOSCount
OBJECT-TYPE
Number of times the DS1 Loss Of Signal (LOS) occurred since we last cleared the alarm history on the local side of the HDSL. (HiGain only)
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.5INTEGERread-onlymandatory
ctWanHDSLAlHistRLOSFirst
OBJECT-TYPE
Time stamp of the first time the DS1 Loss Of Signal (LOS) occurred on the remote side of the HDSL. (HiGain only)
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.6DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistRLOSLast
OBJECT-TYPE
Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred on the remote side of the HDSL. (HiGain only)
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.7DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistRLOSCurrent
OBJECT-TYPE
Set if the DS1 Loss Of Signal (LOS) still occurred on the remote site of the HDSL. (HiGain only)
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.8INTEGERread-onlymandatory
ctWanHDSLAlHistRLOSCount
OBJECT-TYPE
Number of times the DS1 Loss Of Signal (LOS) occurred since we last cleared the alarm history on the remote site of the HDSL. (HiGain only)
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.9INTEGERread-onlymandatory
ctWanHDSLAlHistLOSW1First
OBJECT-TYPE
Time stamp of the first time the Loss Of Sync Word (LOSW) occurred on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.10DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistLOSW1Last
OBJECT-TYPE
Time stamp of the last time the Loss Of Sync Word (LOSW) occurred on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.11DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistLOSW1Current
OBJECT-TYPE
Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.12INTEGERread-onlymandatory
ctWanHDSLAlHistLOSW1Count
OBJECT-TYPE
Number of times the Loss Of Sync Word (LOSW) occurred since we last cleared the history on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.13INTEGERread-onlymandatory
ctWanHDSLAlHistLOSW2First
OBJECT-TYPE
Time stamp of the first time the Loss Of Sync Word (LOSW) occurred on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.14DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistLOSW2Last
OBJECT-TYPE
Time stamp of the last time the Loss Of Sync Word (LOSW) occurred on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.15DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistLOSW2Current
OBJECT-TYPE
Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.16INTEGERread-onlymandatory
ctWanHDSLAlHistLOSW2Count
OBJECT-TYPE
Number of times the Loss Of Sync Word (LOSW) occurred since we last cleared the history on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.17INTEGERread-onlymandatory
ctWanHDSLAlHistES1First
OBJECT-TYPE
Time stamp of the first time the Errored Seconds (ES) occurred on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.18DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistES1Last
OBJECT-TYPE
Time stamp of the last time the Errored Seconds (ES) occurred on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.19DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistES1Current
OBJECT-TYPE
Set if the Errored Seconds (ES) still occurred on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.20INTEGERread-onlymandatory
ctWanHDSLAlHistES1Count
OBJECT-TYPE
Number of times the Errored Seconds (ES) occurred since we last cleared the alarm history on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.21INTEGERread-onlymandatory
ctWanHDSLAlHistES2First
OBJECT-TYPE
Time stamp of the first time the Errored Seconds (ES) occurred on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.22DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistES2Last
OBJECT-TYPE
Time stamp of the last time the Errored Seconds (ES) occurred on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.23DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistES2Current
OBJECT-TYPE
Set if the Errored Seconds (ES) still occurred on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.24INTEGERread-onlymandatory
ctWanHDSLAlHistES2Count
OBJECT-TYPE
Number of times the Errored Seconds (ES) occurred since we last cleared the history on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.25INTEGERread-onlymandatory
ctWanHDSLAlHistMargin1First
OBJECT-TYPE
Time stamp of the first time the alarms exceeded the Margin Threshold on LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.26DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistMargin1Last
OBJECT-TYPE
Time stamp of the last time the alarms exceeded the Margin Threshold on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.27DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistMargin1Current
OBJECT-TYPE
Set if the alarms still exceeded the Margin Threshold on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.28INTEGERread-onlymandatory
ctWanHDSLAlHistMargin1Count
OBJECT-TYPE
Number of times the alarm exceeded the Margin Threshold since we last cleared the alarm history on the LOOP 1 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.29INTEGERread-onlymandatory
ctWanHDSLAlHistMargin2First
OBJECT-TYPE
Time stamp of the first time the alarms exceeded the Margin Threshold on LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.30DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistMargin2Last
OBJECT-TYPE
Time stamp of the last time the alarms exceeded the Margin Threshold on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.31DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistMargin2Current
OBJECT-TYPE
Set if the alarms still exceeded the Margin Threshold on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.32INTEGERread-onlymandatory
ctWanHDSLAlHistMargin2Count
OBJECT-TYPE
Number of times the alarm exceeded the Margin Threshold since we last cleared the alarm history on the LOOP 2 of the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.33INTEGERread-onlymandatory
ctWanHDSLAlHistCleared
OBJECT-TYPE
Time stamp of the time user requested to clear the alarm history.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.34DisplayString (SIZE(12))read-onlymandatory
ctWanHDSLAlHistClearit
OBJECT-TYPE
set to a 1 to clear the alarm history. A read of this value always returns a 1. NOTE: the setting of this object also causes the SNR low value, SNR high value, and the performance history to be reset.
1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.35INTEGERread-writemandatory
ctWanHDSLLoopbacksTable
OBJECT-TYPE
HDSL Loopback table. This table provides the certain loopback settings for the HDSL link.
1.3.6.1.4.1.52.4.1.2.7.1.8.7not-accessiblemandatory
ctWanHDSLLoopbacksEntry
OBJECT-TYPE
Entries in the HDSL Loopback table.
1.3.6.1.4.1.52.4.1.2.7.1.8.7.1not-accessiblemandatory
ctWanHDSLLoopbacksHLUConnIndex
OBJECT-TYPE
Identify the HDSL connection within the device
1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.1INTEGERread-onlymandatory
ctWanHDSLLoopbacksAdminType
OBJECT-TYPE
This is the requested loopback type for the HDSL. loopbacks setting: 1 : Smartjack - loopback to network at remote line unit. 2 : Loopback to network at local line unit. 3 : Loopback to network at remote line unit. 4 : Loopback to customer at local line unit. 5 : Loopback to customer at remote line unit. 6 : Loopback to customer at first doubler. 7 : Loopback to customer at second doubler. 8 : Loopback to network at first doubler. 9 : Loopback to network at second doubler. 10: No loopback (turn loopback off).
1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.2INTEGERread-writemandatory
ctWanHDSLLoopbacksOperType
OBJECT-TYPE
This is the operational loopback type for the HDSL. loopbacks setting: 1 : Smartjack - loopback to network at remote line unit. 2 : Loopback to network at local line unit. 3 : Loopback to network at remote line unit. 4 : Loopback to customer at local line unit. 5 : Loopback to customer at remote line unit. 6 : Loopback to customer at first doubler. 7 : Loopback to customer at second doubler. 8 : Loopback to network at first doubler. 9 : Loopback to network at second doubler. 10: No loopback (turn loopback off).
1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.3INTEGERread-onlymandatory