CTRON-UPS-MIB
- Registered at
- 1.3.6.1.4.1.52.4.1.5.4.1
- Namespace
- enterasys
- Source file
CTRON-UPS-MIB- Digest
sha256:2a0a381260dcb1de00d41f61d4674b8b6a7ee7895ff0cd37b0859fda0f526c70
Imports
| From | Symbols |
|---|---|
| CTRON-MIB-NAMES | ctUPowerSupply |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CTRON-MIB-NAMES CTRON-OIDS CTRON-UPS-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ctUPS OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.1.5.4.1 | |||
| ctUpsID OBJECT-TYPE Denotes a type code which refers to the manufacturers and model of the UPS. | 1.3.6.1.4.1.52.4.1.5.4.1.1 | INTEGER {other(1), aPCModel370(257), aPCModel400(258), aPCModel600(259), aPCModel900(260), aPCModel1250(261), aPCModel2000(262), matrix3000(263), matrix5000(264), su700(265), su1400(266), su2000XL(267), aPCGeneric(268)} | read-write | mandatory |
| ctUpsUpTime OBJECT-TYPE Denotes the operating time, in hours, since the UPS was last powered on. | 1.3.6.1.4.1.52.4.1.5.4.1.2 | INTEGER | read-only | deprecated |
| ctUpsDisable OBJECT-TYPE Allows the UPS to be disabled. A set turns of the UPS for those systems, so equipped. A get/get-next always returns 0. | 1.3.6.1.4.1.52.4.1.5.4.1.3 | INTEGER | read-write | deprecated |
| ctUpsDisconnect OBJECT-TYPE Allows the UPS backup power system to conserve its battery. A set turns off the power system. A get/get-next always returns a 0. | 1.3.6.1.4.1.52.4.1.5.4.1.4 | INTEGER | read-write | mandatory |
| ctUpsTest OBJECT-TYPE Denotes the status performed on the UPS. A write initiates the test. A read indicates status of test. | 1.3.6.1.4.1.52.4.1.5.4.1.5 | INTEGER {unitOK(1), unitFailed(2), badBattery(3), noRecentTest(4), underTest(5)} | read-write | mandatory |
| ctUpsBatteryCapacity OBJECT-TYPE Denotes the percentage of battery capacity left, 100% being a fully-charged battery. | 1.3.6.1.4.1.52.4.1.5.4.1.6 | INTEGER | read-only | mandatory |
| ctUpsACLineVoltsIn OBJECT-TYPE Denotes the input AC utility line voltage. | 1.3.6.1.4.1.52.4.1.5.4.1.7 | INTEGER | read-only | mandatory |
| ctUpsBatteryVoltsOut OBJECT-TYPE Denotes the battery voltage. | 1.3.6.1.4.1.52.4.1.5.4.1.8 | INTEGER | read-only | mandatory |